HomeMy WebLinkAboutAPPROVED WS 20 - Truss Package [ds] 2.22.20216904 Parke East Blvd.
Tampa, FL 33610-4115
MiTek USA, Inc. RE: WS0020 -
Design Code: FBC2020/TPI2014
Wind Code: N/A Wind Speed: 165 mph
Roof Load: 37.0 psf
Design Program: MiTek 20/20 8.4
1 of 2
This package includes 40 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Floor Load: 55.0 psf
Site Information:
Lot/Block: 20
Customer Info: K Hovnanaian Homes Project Name: WS0020 Model: Emerald-B
Subdivision: Waterstone
Address: 5146 Armina Pl., .
State: FLCity: Fort Pierce
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
February 19,2021
Lee, Julius
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by Builders FirstSource (Lady Lake, FL).
Truss Design Engineer's Name: Lee, Julius
My license renewal date for the state of Florida is February 28, 2021.
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
No.Seal#Truss Name
1 T22912211 CJ01
Date
2/19/212T22912212CJ12/19/213T22912213CJ032/19/214T22912214CJ32/19/215T22912215CJ52/19/216T22912216EJ052/19/217T22912217EJ72/19/218T22912218FG012/19/219T22912219FG022/19/2110T22912220FG032/19/2111T22912221FL012/19/2112T22912222FL022/19/2113T22912223FL02A2/19/2114T22912224FL032/19/21
No.Seal#Truss Name
15 T22912225 FL04
Date
2/19/2116T22912226FL052/19/2117T22912227FL062/19/2118T22912228FL072/19/2119T22912229HJ052/19/2120T22912230HJ72/19/2121T22912231T092/19/2122T22912232T102/19/2123T22912233T112/19/2124T22912234T122/19/2125T22912235T132/19/2126T22912236T142/19/2127T22912237T152/19/2128T22912238T162/19/21
This item has been electronically signed and sealed by Lee, Julius, PE using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
6904 Parke East Blvd.
Tampa, FL 33610-4115
MiTek USA, Inc. RE: WS0020 -
2 of 2
Site Information:
Lot/Block: 20
Customer Info: K Hovnanaian Homes Project Name: WS0020 Model: Emerald-B
Subdivision: Waterstone
Address: 5146 Armina Pl., .
State: FLCity: Fort Pierce
No.Seal#Truss Name
29 T22912239 T17
Date
2/19/2130T22912240T182/19/2131T22912241T192/19/2132T22912242T202/19/2133T22912243T212/19/2134T22912244T222/19/2135T22912245T232/19/2136T22912246T242/19/2137T22912247T252/19/2138T22912248T262/19/2139T22912249V022/19/2140T22912250V032/19/21
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
CJ01
Truss Type
Corner Jack
Qty
4
Ply
1
Job Reference (optional)
T22912211
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:49:57 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-hpcFcPkpbBF5qI4yZCcAjB8JV2?qVPKAKiXz8lzjeDu
Scale = 1:6.1
1
2
3
4
2x4
ST1.5x8 STP 1-0-0
1-0-0
-1-0-0
1-0-0
1-0-0
1-0-0
0-3-150-7-150-3-120-7-154.00 12
Plate Offsets (X,Y)-- [2:0-2-14,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.17
0.01
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
-0.00
(loc)
2
2
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 5 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=38(LC 12)
Max Uplift 3=-8(LC 1), 2=-119(LC 12)
Max Grav 3=21(LC 12), 2=125(LC 1), 4=18(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=119.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
CJ1
Truss Type
Corner Jack
Qty
4
Ply
1
Job Reference (optional)
T22912212
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:49:59 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-dCk?05m36pVp3cEKhdfeocEf_shGzJpTn004CezjeDs
Scale = 1:6.5
1
2
3
4
2x4
1-0-0
1-0-0
-1-0-0
1-0-0
1-0-0
1-0-0
0-4-10-9-10-4-100-9-15.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.17
0.02
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
2
2
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 5 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-114(LC 12)
Max Grav 3=16(LC 12), 2=121(LC 1), 4=19(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=114.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
CJ03
Truss Type
Corner Jack
Qty
4
Ply
1
Job Reference (optional)
T22912213
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:49:58 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-9?AdpllRMVNySSf87v8PGPhStSJGEsZJZMHXgCzjeDt
Scale = 1:9.4
1
2
5
3
4
2x4
ST1.5x8 STP
3-0-0
3-0-0
-1-0-0
1-0-0
3-0-0
3-0-0
0-3-151-3-150-4-30-11-121-3-154.00 12
Plate Offsets (X,Y)-- [2:0-2-14,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.26
0.13
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.01
-0.00
(loc)
2-4
2-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=68(LC 12)
Max Uplift 3=-36(LC 12), 2=-137(LC 12)
Max Grav 3=52(LC 1), 2=187(LC 1), 4=52(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=137.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
CJ3
Truss Type
Corner Jack
Qty
4
Ply
1
Job Reference (optional)
T22912214
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:49:59 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-dCk?05m36pVp3cEKhdfeocEessfAzJpTn004CezjeDs
Scale = 1:10.8
1
2
5
3
4
2x4
3-0-0
3-0-0
-1-0-0
1-0-0
3-0-0
3-0-0
0-4-11-7-11-2-101-7-15.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.24
0.15
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.01
-0.00
(loc)
2-4
2-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-50(LC 12), 2=-119(LC 12)
Max Grav 3=63(LC 1), 2=178(LC 1), 4=56(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-11-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=119.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
CJ5
Truss Type
Corner Jack
Qty
4
Ply
1
Job Reference (optional)
T22912215
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:00 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-5OINEQmht6dghlpXEKAtLqmjLGyJim3c0gmek4zjeDr
Scale = 1:14.9
1
2
5
6
3
4
2x4
5-0-0
5-0-0
-1-0-0
1-0-0
5-0-0
5-0-0
0-4-12-5-12-0-102-5-15.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.58
0.28
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.03
-0.06
-0.00
(loc)
2-4
2-4
3
l/defl
>999
>909
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 17 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical
Max Horz 2=124(LC 12)
Max Uplift 3=-103(LC 12), 2=-136(LC 12)
Max Grav 3=122(LC 1), 2=247(LC 1), 4=96(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
3=103, 2=136.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
EJ05
Truss Type
Jack-Open
Qty
2
Ply
1
Job Reference (optional)
T22912216
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:00 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-5OINEQmht6dghlpXEKAtLqmj8Gygim3c0gmek4zjeDr
Scale = 1:12.7
1
2
5
6
3
4
2x4
ST1.5x8 STP 5-0-0
5-0-0
-1-0-0
1-0-0
5-0-0
5-0-0
0-3-151-11-154.00 12
Plate Offsets (X,Y)-- [2:0-2-14,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.59
0.26
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.03
-0.05
-0.00
(loc)
2-4
2-4
3
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 17 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=99(LC 12)
Max Uplift 3=-89(LC 12), 2=-155(LC 12)
Max Grav 3=114(LC 1), 2=253(LC 1), 4=92(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-11-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=155.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
EJ7
Truss Type
Jack-Open
Qty
14
Ply
1
Job Reference (optional)
T22912217
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:01 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-ZaslRmnKeQlXJvOjo2h6t1Jq3fE9RDJlFKVBHWzjeDq
Scale = 1:18.8
1
2
5
6
3
4
3x6
7-0-0
7-0-0
-1-0-0
1-0-0
7-0-0
7-0-0
0-4-13-3-12-10-103-3-15.00 12
Plate Offsets (X,Y)-- [2:0-0-2,0-0-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.84
0.56
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.13
-0.21
-0.00
(loc)
2-4
2-4
3
l/defl
>607
>394
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-3-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical
Max Horz 2=163(LC 12)
Max Uplift 3=-132(LC 12), 2=-157(LC 12)
Max Grav 3=165(LC 1), 2=318(LC 1), 4=125(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-11-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
3=132, 2=157.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FG01
Truss Type
FLOOR
Qty
1
Ply
2
Job Reference (optional)
T22912218
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:01 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-ZaslRmnKeQlXJvOjo2h6t1JvUfGHR2nlFKVBHWzjeDq
Scale = 1:12.6
1 2 3
6 5 4
6x8
6x8
2x4 2x4
5x8
2x4
0-3-0
0-3-0
3-7-0
3-4-0
6-11-0
3-4-0
0-3-0
0-3-0
3-7-0
3-4-0
6-11-0
3-4-0
1-5-12Plate Offsets (X,Y)-- [5:0-4-0,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.55
0.43
0.74
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.05
-0.07
0.00
(loc)
5
5
4
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 85 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except*
1-5,3-5: 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)4=0-4-0, 6=0-4-0
Max Grav 4=3298(LC 1), 6=3298(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4982/0, 2-3=-4982/0, 3-4=-2545/0
WEBS 1-5=0/5231, 2-5=-1927/0, 3-5=0/5231, 1-6=-2545/0
NOTES-(5)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Girder carries tie-in span(s): 20-6-4 from 0-0-0 to 6-11-0; 17-9-4 from 0-0-0 to 6-11-0
4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-3=-600(F=-500), 4-6=-435(B=-425)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FG02
Truss Type
FLOOR
Qty
2
Ply
2
Job Reference (optional)
T22912219
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:02 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-1nQ8f6oyPktOw3zvMlCLQFs?03ZhAUhvU_FkpzzjeDp
Scale = 1:31.2
1 2 3 4 5 6 7
14 13 12 11 10 9 8
4x6
ST1.5x8 STP
5x8
3x6 5x8
4x6 6x12 MT20HS
2x4
10x12 10x12
5x6 5x6 2x4
2x4 2x4
3-10-0
3-10-0
7-4-8
3-6-8
10-6-0
3-1-8
14-2-4
3-8-4
18-0-4
3-10-0
3-10-0
3-10-0
7-4-8
3-6-8
10-6-0
3-1-8
14-2-4
3-8-4
18-0-4
3-10-0
1-6-0Plate Offsets (X,Y)-- [1:Edge,0-1-8], [7:Edge,0-1-8], [8:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.89
0.61
0.82
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.32
-0.43
0.03
(loc)
9-10
9-10
8
l/defl
>667
>489
n/a
L/d
360
240
n/a
PLATES
MT20
MT20HS
Weight: 192 lb FT = 20%
GRIP
244/190
187/143
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.3 *Except*
7-9,1-13,3-13,4-9: 2x4 SP No.1
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)14=0-7-4, 8=0-3-8
Max Grav 14=1566(LC 1), 8=3227(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-14=-1358/0, 1-2=-4011/0, 2-3=-4011/0, 3-4=-8182/0, 4-6=-8747/0, 6-7=-8747/0,
7-8=-2789/0
BOT CHORD 11-13=0/8182, 10-11=0/8182, 9-10=0/8182, 8-9=0/464
WEBS 6-9=-301/40, 7-9=0/8660, 1-13=0/3945, 3-13=-4446/0, 4-9=0/1220, 2-13=-317/24,
3-11=0/954, 4-10=-590/0
NOTES-(8)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 2 rows staggered at 0-2-0 oc, Except member 9-7 2x4 - 1 row at 0-9-0 oc, member 1-13 2x4 - 1
row at 0-9-0 oc, member 13-3 2x4 - 1 row at 0-9-0 oc, member 4-9 2x4 - 1 row at 0-9-0 oc, member 13-2 2x4 - 1 row at 0-9-0 oc,
member 3-11 2x4 - 1 row at 0-9-0 oc, member 10-4 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced floor live loads have been considered for this design.
4) All plates are MT20 plates unless otherwise indicated.
5) The Fabrication Tolerance at joint 5 = 20%, joint 12 = 20%
6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2843 lb down at 14-2-4 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-7=-100, 8-14=-10
Continued on page 2
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FG02
Truss Type
FLOOR
Qty
2
Ply
2
Job Reference (optional)
T22912219
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:02 2021 Page 2 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-1nQ8f6oyPktOw3zvMlCLQFs?03ZhAUhvU_FkpzzjeDp
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 9=-2843(F)
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FG03
Truss Type
FLOOR
Qty
1
Ply
2
Job Reference (optional)
T22912220
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:03 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-Vz_WsSpaA10FYDX6wSjaySOE3Tydvwz2ie_ILPzjeDo
Scale = 1:19.9
1 2 3 4
8 7 6 591011121314
4x6
5x6
5x6
4x6
5x8
2x4 4x6
5x6
4-0-9
4-0-9
7-11-7
3-10-13
12-0-0
4-0-9
4-0-9
4-0-9
7-11-7
3-10-13
12-0-0
4-0-9
1-5-12Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [4:0-3-0,0-1-12], [5:Edge,0-2-0], [6:0-3-0,0-1-12], [7:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.61
0.44
0.89
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.15
-0.21
0.01
(loc)
6-7
6-7
5
l/defl
>910
>669
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 151 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.2 *Except*
2-7,3-6: 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-2-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)8=Mechanical, 5=Mechanical
Max Grav 8=2934(LC 1), 5=2853(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-8=-1938/0, 1-2=-6693/0, 2-3=-6693/0, 3-4=-6806/0, 4-5=-1957/0
BOT CHORD 7-8=0/737, 6-7=0/6806, 5-6=0/729
WEBS 1-7=0/6157, 4-6=0/6281
NOTES-(6)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Refer to girder(s) for truss to truss connections.
4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 751 lb down at 0-10-12, 750 lb
down at 2-10-12, 750 lb down at 4-10-12, 750 lb down at 6-10-12, and 750 lb down at 8-10-12, and 750 lb down at 10-10-12 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (plf)
Vert: 1-4=-100, 5-8=-10
Concentrated Loads (lb)
Vert: 9=-751(B) 10=-750(B) 11=-750(B) 12=-750(B) 13=-750(B) 14=-750(B)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL01
Truss Type
Floor Supported Gable
Qty
2
Ply
1
Job Reference (optional)
T22912221
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:04 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-_9Xu4opCxL86AN6ITAEpVgxX6tOVeaZCxIkrurzjeDn
Scale = 1:34.4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19
37
38
3x6 FP 3x4
3x4 3x6 FP
20-9-12
20-9-12
0-1-8
1-6-01-6-0LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.08
0.01
0.03
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
19
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 96 lb FT = 20%F, 11%E
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.2(flat)
WEBS 2x4 SP No.3(flat)
OTHERS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 20-9-12.
(lb) - Max Grav All reactions 250 lb or less at joint(s) 36, 19, 35, 34, 33, 32, 31, 29, 28, 27, 26, 25, 24, 23, 22,
21, 20
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) All plates are 1.5x3 MT20 unless otherwise indicated.
2) Gable requires continuous bottom chord bearing.
3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4) Gable studs spaced at 1-4-0 oc.
5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6) CAUTION, Do not erect truss backwards.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL02
Truss Type
FLOOR
Qty
7
Ply
1
Job Reference (optional)
T22912222
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:04 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-_9Xu4opCxL86AN6ITAEpVgxK0tAfePuCxIkrurzjeDn
Scale = 1:35.0
1 2 3 4 5 6 7 8 9 10 11
18 17 16 15 14 13 12
19
20
3x12 MT20HS FP
1.5x3
1.5x3
1.5x3
3x4 3x6 FP
3x6
4x6
5x8
1.5x3 3x4
3x4 3x6
4x6
5x8
1.5x3
3x4
3x4
1.5x3 1.5x3
20-9-12
20-9-12
2-5-0 1-7-14 2-0-0 1-7-14
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [14:0-1-8,Edge], [15:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.92
0.90
0.71
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.36
-0.49
0.09
(loc)
13-14
13-14
12
l/defl
>681
>504
n/a
L/d
360
240
n/a
PLATES
MT20
MT20HS
Weight: 106 lb FT = 20%F, 11%E
GRIP
244/190
187/143
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)18=0-7-4, 12=0-3-8
Max Grav 18=1128(LC 1), 12=1128(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3126/0, 3-4=-3126/0, 4-5=-4172/0, 5-6=-4172/0, 6-7=-4172/0, 7-9=-3152/0,
9-10=-3152/0
BOT CHORD 17-18=0/1815, 15-17=0/3898, 14-15=0/4172, 13-14=0/3912, 12-13=0/1855
WEBS 2-18=-2075/0, 2-17=0/1499, 4-17=-883/0, 4-15=-70/684, 10-12=-2109/0, 10-13=0/1484,
7-13=-869/0, 7-14=-82/673, 5-15=-315/0, 6-14=-310/0
NOTES-(5)
1) Unbalanced floor live loads have been considered for this design.
2) All plates are MT20 plates unless otherwise indicated.
3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
4) CAUTION, Do not erect truss backwards.
5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL02A
Truss Type
Floor
Qty
6
Ply
1
Job Reference (optional)
T22912223
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:05 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-SM5GH8qqifGznXhU1tm22tUVmHWuNr8LAyTPQIzjeDm
Scale = 1:34.2
1 2 3 4 5 6 7 8 9 10 11
18 17 16 15 14 13 12
19
20 21
3x12 MT20HS FP
3x6 FP
3x6
4x6
5x8
3x4
3x4 3x6
4x6
5x8
3x4
3x4
20-9-12
20-9-12
2-5-0 1-7-14 2-0-0 1-7-14
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [14:0-1-8,Edge], [15:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.92
0.90
0.71
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.36
-0.49
0.09
(loc)
13-14
13-14
12
l/defl
>681
>504
n/a
L/d
360
240
n/a
PLATES
MT20
MT20HS
Weight: 106 lb FT = 20%F, 11%E
GRIP
244/190
187/143
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)18=0-7-4, 12=0-3-8
Max Grav 18=1127(LC 1), 12=1121(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3126/0, 3-4=-3126/0, 4-5=-4172/0, 5-6=-4172/0, 6-7=-4172/0, 7-9=-3153/0,
9-10=-3153/0
BOT CHORD 17-18=0/1815, 15-17=0/3898, 14-15=0/4172, 13-14=0/3912, 12-13=0/1853
WEBS 2-18=-2075/0, 2-17=0/1499, 4-17=-883/0, 4-15=-70/684, 10-12=-2102/0, 10-13=0/1486,
7-13=-868/0, 7-14=-82/673, 5-15=-315/0, 6-14=-310/0
NOTES-(6)
1) Unbalanced floor live loads have been considered for this design.
2) All plates are MT20 plates unless otherwise indicated.
3) All plates are 1.5x3 MT20 unless otherwise indicated.
4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5) CAUTION, Do not erect truss backwards.
6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL03
Truss Type
Floor
Qty
4
Ply
1
Job Reference (optional)
T22912224
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:06 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-wYfeUUrSTyOqPgGgbbHHa50gAgsO6JeVOcDyykzjeDl
Scale = 1:34.5
1 2 3 4 5 6 7 8 9 10 11
18 17 16 15 14 13 12
19
20
3x12 MT20HS FP
1.5x3
1.5x3
1.5x3
3x4 3x6 FP
3x6
4x6
5x8
1.5x3 3x4
3x6
4x6
5x8
1.5x3 3x4 1.5x3
3x4
1.5x3
3x4
20-6-4
20-6-4
2-5-0 1-7-14 2-0-0 1-4-6
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [14:0-1-8,Edge], [15:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.94
0.88
0.70
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.35
-0.47
0.08
(loc)
15-17
15-17
12
l/defl
>697
>514
n/a
L/d
360
240
n/a
PLATES
MT20
MT20HS
Weight: 105 lb FT = 20%F, 11%E
GRIP
244/190
187/143
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)18=0-7-4, 12=Mechanical
Max Grav 18=1111(LC 1), 12=1111(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3069/0, 3-4=-3069/0, 4-5=-4052/0, 5-6=-4052/0, 6-7=-4052/0, 7-9=-3093/0,
9-10=-3093/0
BOT CHORD 17-18=0/1787, 15-17=0/3811, 14-15=0/4052, 13-14=0/3825, 12-13=0/1824
WEBS 2-18=-2043/0, 2-17=0/1467, 4-17=-849/0, 10-12=-2074/0, 10-13=0/1451, 7-13=-837/0,
5-15=-299/0, 4-15=-88/645, 6-14=-339/10, 7-14=-91/650
NOTES-(6)
1) Unbalanced floor live loads have been considered for this design.
2) All plates are MT20 plates unless otherwise indicated.
3) Refer to girder(s) for truss to truss connections.
4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5) CAUTION, Do not erect truss backwards.
6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL04
Truss Type
Floor Supported Gable
Qty
2
Ply
1
Job Reference (optional)
T22912225
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:07 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-OkD1iqs4EGWh1qrt9IoW7IZ2E4PyrwHedGyVUAzjeDk
Scale = 1:29.3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
29 28 27 26 25 24 23 22 21 20 19 18 17 16
30
31
3x6
3x4
17-8-12
17-8-12
0-1-8
1-6-01-6-0LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-R
0.09
0.03
0.03
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
16
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 83 lb FT = 20%F, 11%E
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.2(flat)
WEBS 2x4 SP No.3(flat)
OTHERS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.All bearings 17-8-12.
(lb) - Max Grav All reactions 250 lb or less at joint(s) 29, 16, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) All plates are 1.5x3 MT20 unless otherwise indicated.
2) Gable requires continuous bottom chord bearing.
3) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4) Gable studs spaced at 1-4-0 oc.
5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
6) CAUTION, Do not erect truss backwards.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL05
Truss Type
Floor
Qty
8
Ply
1
Job Reference (optional)
T22912226
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:07 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-OkD1iqs4EGWh1qrt9IoW7IZtL4BHro1edGyVUAzjeDk
Scale = 1:29.8
1 2 3 4 5 6 7 8 9
16 15 14 13 12 11 10
17
18
3x4
3x6 3x4
3x6
3x8
3x4 3x6
3x8
3x4
10-4-12
10-4-12
18-0-4
7-7-8
2-5-0 2-0-0 0-4-12
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [6:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.79
0.90
0.56
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.29
-0.36
0.06
(loc)
11-12
11-12
10
l/defl
>740
>596
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 94 lb FT = 20%F, 11%E
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)10=0-3-8, 16=0-7-4
Max Grav 10=974(LC 1), 16=974(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2570/0, 3-4=-2570/0, 4-5=-3100/0, 5-6=-3100/0, 6-7=-2591/0, 7-8=-2591/0
BOT CHORD 15-16=0/1538, 14-15=0/3100, 13-14=0/3100, 12-13=0/3100, 11-12=0/3100, 10-11=0/1571
WEBS 2-16=-1759/0, 2-15=0/1180, 3-15=-293/21, 4-15=-854/0, 8-10=-1786/0, 8-11=0/1166,
7-11=-295/15, 6-11=-837/0
NOTES-(5)
1) Unbalanced floor live loads have been considered for this design.
2) All plates are 1.5x3 MT20 unless otherwise indicated.
3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
4) CAUTION, Do not erect truss backwards.
5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL06
Truss Type
Floor
Qty
4
Ply
1
Job Reference (optional)
T22912227
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:08 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-sxnPv9tj?aeYf_Q3i0JlfW63DUYXaFTnswi31dzjeDj
Scale = 1:29.3
1 2 3 4 5 6 7 8 9
16 15 14 13 12 11 10
17
18
3x4
3x6 3x4
3x6
3x8
3x4 3x6
3x8
3x4
10-1-12
10-1-12
17-9-4
7-7-8
2-5-0 2-0-0 0-1-12
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [6:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.71
0.84
0.55
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.25
-0.32
0.05
(loc)
11-12
11-12
10
l/defl
>822
>653
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 93 lb FT = 20%F, 11%E
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)10=Mechanical, 16=0-7-4
Max Grav 10=960(LC 1), 16=960(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2522/0, 3-4=-2522/0, 4-5=-3020/0, 5-6=-3020/0, 6-7=-2542/0, 7-8=-2542/0
BOT CHORD 15-16=0/1513, 14-15=0/3020, 13-14=0/3020, 12-13=0/3020, 11-12=0/3020, 10-11=0/1546
WEBS 2-16=-1730/0, 2-15=0/1153, 3-15=-291/14, 4-15=-807/0, 8-10=-1757/0, 8-11=0/1139,
7-11=-292/9, 6-11=-791/0
NOTES-(6)
1) Unbalanced floor live loads have been considered for this design.
2) All plates are 1.5x3 MT20 unless otherwise indicated.
3) Refer to girder(s) for truss to truss connections.
4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
5) CAUTION, Do not erect truss backwards.
6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
FL07
Truss Type
Floor
Qty
6
Ply
1
Job Reference (optional)
T22912228
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:09 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-K7Ln7VtLmtmOG8?FGjq_CjeC6uu5Jk0x5aRcZ3zjeDi
Scale: 1/2"=1'
1 2 3 4 5 6 7
12 11 10 9 8
13
14
1.5x3
1.5x3
1.5x3
1.5x3
3x4
3x4
3x6
1.5x3 3x4
1.5x3 3x4
3x4
3x4
1.5x3
14-0-12
14-0-12
2-5-0 2-0-0 1-7-12
0-1-8
1-6-01-6-0Plate Offsets (X,Y)-- [4:0-1-8,Edge], [9:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
40.0
10.0
0.0
5.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.00
1.00
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.83
0.88
0.40
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.23
-0.30
0.03
(loc)
10-11
10-11
8
l/defl
>712
>556
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 71 lb FT = 20%F, 11%E
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.1(flat)
BOT CHORD 2x4 SP No.1(flat)
WEBS 2x4 SP No.3(flat)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)12=0-7-4, 8=Mechanical
Max Grav 12=760(LC 1), 8=760(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1834/0, 3-4=-1834/0, 4-5=-1775/0, 5-6=-1775/0
BOT CHORD 11-12=0/1153, 10-11=0/1775, 9-10=0/1775, 8-9=0/1163
WEBS 2-12=-1319/0, 2-11=0/779, 3-11=-331/0, 4-11=-269/229, 6-8=-1330/0, 6-9=0/845,
5-9=-366/0
NOTES-(5)
1) Unbalanced floor live loads have been considered for this design.
2) Refer to girder(s) for truss to truss connections.
3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails.
Strongbacks to be attached to walls at their outer ends or restrained by other means.
4) CAUTION, Do not erect truss backwards.
5) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
HJ05
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
Job Reference (optional)
T22912229
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:10 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-oJv9KruzXBuFuIaSqRLDlxBRxIKo2HX4JEB95VzjeDh
Scale = 1:15.7
1
2
5
3
6 7 4
3x4
7-0-2
7-0-2
-1-5-0
1-5-0
7-0-2
7-0-2
0-3-151-11-122.83 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.63
0.47
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.08
-0.16
-0.00
(loc)
2-4
2-4
3
l/defl
>978
>510
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 23 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)3=Mechanical, 2=0-10-15, 4=Mechanical
Max Horz 2=106(LC 4)
Max Uplift 3=-122(LC 4), 2=-262(LC 4)
Max Grav 3=154(LC 1), 2=301(LC 1), 4=114(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(9)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint 3 and 262 lb uplift at
joint 2.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 46 lb up at 4-2-15, and 46 lb up
at 4-2-15 on top chord, and 37 lb up at 1-4-15, 37 lb up at 1-4-15, and at 4-2-15, and at 4-2-15 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 2-4=-20
Concentrated Loads (lb)
Vert: 6=61(F=30, B=30)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
HJ7
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
Job Reference (optional)
T22912230
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:11 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-GVTXYBvbIV06WS9eO8sSH8kgdhh2ngGEYuwjdxzjeDg
Scale = 1:20.6
1
2
3
7 6
8
9
10
4
11 12 13
52x4 3x4
3x4
2x4
5-8-1
5-8-1
9-10-1
4-1-15
-1-5-0
1-5-0
5-8-1
5-8-1
9-10-1
4-1-15
0-4-13-2-133.54 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.32
0.40
0.29
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.03
-0.05
0.01
(loc)
6-7
6-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 40 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)4=Mechanical, 2=0-4-9, 5=Mechanical
Max Horz 2=162(LC 8)
Max Uplift 4=-93(LC 8), 2=-189(LC 8), 5=-125(LC 8)
Max Grav 4=107(LC 1), 2=449(LC 1), 5=329(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-759/261
BOT CHORD 2-7=-320/696, 6-7=-320/696
WEBS 3-6=-761/350, 3-7=0/301
NOTES-(9)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 93 lb uplift at joint 4, 189 lb uplift at joint
2 and 125 lb uplift at joint 5.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 45 lb down and 26 lb up at
1-4-15, 45 lb down and 26 lb up at 1-4-15, 62 lb up at 4-2-15, 62 lb up at 4-2-15, and 46 lb down and 124 lb up at 7-0-14, and 46
lb down and 124 lb up at 7-0-14 on top chord, and at 1-4-15, at 1-4-15, at 4-2-15, at 4-2-15, and 39 lb down at 7-0-14, and 39
lb down at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 2-5=-20
Concentrated Loads (lb)
Vert: 8=42(F=21, B=21) 10=-91(F=-46, B=-46) 13=-39(F=-20, B=-20)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T09
Truss Type
Hip
Qty
2
Ply
1
Job Reference (optional)
T22912231
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:12 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-li0vlXwD3o8z7bkqxrOhqMGif5xqW30NnYgGAOzjeDf
Scale = 1:60.4
1 2
3
4 5 6
7
8 9
15 14 13 12 11 10
16
17 18
19
20 21
4x6 4x6
3x6 4x6
3x4
2x4 3x8
3x4
3x8
3x4
2x4 4x6 3x6
7-7-12
7-7-12
13-0-0
5-4-4
22-0-0
9-0-0
27-4-4
5-4-4
35-0-0
7-7-12
-1-0-0
1-0-0
7-7-12
7-7-12
13-0-0
5-4-4
17-6-0
4-6-0
22-0-0
4-6-0
27-4-4
5-4-4
35-0-0
7-7-12
36-0-0
1-0-0
0-4-15-9-10-4-15-9-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [8:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.88
0.75
0.51
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.33
-0.59
0.13
(loc)
12-13
12-13
8
l/defl
>999
>705
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 173 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 5-10-9 oc bracing.
REACTIONS. (size)2=0-3-8, 8=0-3-8
Max Horz 2=-130(LC 10)
Max Uplift 2=-627(LC 12), 8=-627(LC 12)
Max Grav 2=1460(LC 17), 8=1460(LC 18)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2949/1282, 3-4=-2364/1083, 4-5=-2148/1049, 5-6=-2148/1049, 6-7=-2364/1083,
7-8=-2949/1282
BOT CHORD 2-15=-1068/2744, 13-15=-1068/2744, 12-13=-840/2231, 10-12=-1080/2670,
8-10=-1080/2670
WEBS 3-15=0/260, 3-13=-675/373, 4-13=-236/706, 5-13=-295/141, 5-12=-295/141,
6-12=-236/706, 7-12=-676/373, 7-10=0/260
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 13-0-0, Exterior(2R)
13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2R) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36-0-0 zone; cantilever left and
right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 8.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T10
Truss Type
Hip
Qty
2
Ply
1
Job Reference (optional)
T22912232
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:13 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-DuaIytwrp6GqllI1VZvwMZpszVDhFSGX?CPqiqzjeDe
Scale = 1:61.4
1 2
3
4
5 6
7
8
9 10
16 15 14 13 12 11
17
18
19 20
21
22
3x6
5x8 4x6
3x6
3x6
3x6
3x4
2x4 3x4 3x8
3x4
2x4 3x6
3x6
8-9-1
8-9-1
15-0-0
6-2-15
20-0-0
5-0-0
26-2-15
6-2-15
35-0-0
8-9-1
-1-0-0
1-0-0
8-9-1
8-9-1
15-0-0
6-2-15
20-0-0
5-0-0
26-2-15
6-2-15
35-0-0
8-9-1
36-0-0
1-0-0
0-4-16-7-10-4-16-7-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [5:0-5-12,0-2-8], [9:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.90
0.97
0.77
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.22
-0.42
0.13
(loc)
2-16
2-16
9
l/defl
>999
>998
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 171 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2 *Except*
1-4,7-10: 2x4 SP No.1
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS. (size)2=0-3-8, 9=0-3-8
Max Horz 2=-149(LC 10)
Max Uplift 2=-627(LC 12), 9=-627(LC 12)
Max Grav 2=1346(LC 1), 9=1346(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2667/1251, 3-5=-1961/1023, 5-6=-1746/997, 6-8=-1961/1023, 8-9=-2666/1251
BOT CHORD 2-16=-1029/2376, 14-16=-1029/2376, 13-14=-663/1745, 11-13=-1041/2376,
9-11=-1041/2376
WEBS 3-16=0/341, 3-14=-746/428, 5-14=-178/466, 6-13=-184/467, 8-13=-745/427, 8-11=0/341
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 15-0-0, Exterior(2R)
15-0-0 to 19-2-15, Interior(1) 19-2-15 to 20-0-0, Exterior(2R) 20-0-0 to 24-2-15, Interior(1) 24-2-15 to 36-0-0 zone; cantilever left and
right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 9.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T11
Truss Type
Hip
Qty
2
Ply
1
Job Reference (optional)
T22912233
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:14 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-h48gADxTaQOhNvtD3GQ9vnL4Lvcl_xqgEs9NEGzjeDd
Scale = 1:61.3
1 2
3
4
5
6 7 8
9
10
11
12 13
18 17 16 15 14
19
20
21
22
23 24
3x6
3x6 3x6
3x6
3x6
4x6 3x4
2x4
3x4
3x8
3x4
3x4
2x4
4x6
3x6
3x6
8-9-9
8-9-9
17-0-0
8-2-7
17-6-0
0-6-0
18-0-0
0-6-0
26-2-7
8-2-7
35-0-0
8-9-9
-1-0-0
1-0-0
6-10-12
6-10-12
12-3-13
5-5-1
17-0-0
4-8-3
17-6-0
0-6-0
18-0-0
0-6-0
22-8-3
4-8-3
28-1-4
5-5-1
35-0-0
6-10-12
36-0-0
1-0-0
0-4-17-5-10-4-17-5-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [6:0-3-0,0-2-4], [8:0-3-0,0-2-4], [12:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.74
0.79
0.69
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.27
-0.47
0.12
(loc)
16-18
16-18
12
l/defl
>999
>892
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 170 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-3-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-1 oc bracing.
REACTIONS. (size)2=0-3-8, 12=0-3-8
Max Horz 2=-167(LC 10)
Max Uplift 2=-627(LC 12), 12=-627(LC 12)
Max Grav 2=1460(LC 19), 12=1460(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2984/1247, 3-5=-2826/1212, 5-6=-1923/915, 6-7=-1737/879, 7-8=-1737/879,
8-9=-1923/915, 9-11=-2826/1212, 11-12=-2984/1247
BOT CHORD 2-18=-1043/2772, 16-18=-779/2204, 14-16=-791/2174, 12-14=-1056/2708
WEBS 3-18=-314/263, 5-18=-207/713, 5-16=-671/386, 9-16=-671/386, 9-14=-207/713,
11-14=-314/263, 7-16=-469/1204
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-0-0, Exterior(2E)
17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36-0-0 zone; cantilever left and right exposed ; end vertical left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 12.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T12
Truss Type
Common
Qty
2
Ply
1
Job Reference (optional)
T22912234
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:15 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-9Hi2NZy6LjWY_3SPd_xOS_uF3Jy_jOupTWuwmjzjeDc
Scale = 1:59.3
1 2
3
4
5
6
7
8
9
10 11
16 15 14 13 12
17
18 19
20
21 22
3x6
4x6
3x6
3x6 4x6 3x8
3x4
3x4
2x4
3x4
3x4
2x4
4x6 3x6
8-9-9
8-9-9
17-6-0
8-8-7
26-2-7
8-8-7
35-0-0
8-9-9
-1-0-0
1-0-0
6-10-11
6-10-11
12-3-12
5-5-1
17-6-0
5-2-4
22-8-4
5-2-4
28-1-5
5-5-1
35-0-0
6-10-11
36-0-0
1-0-0
0-4-17-7-90-4-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [10:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.74
0.79
0.70
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.27
-0.46
0.12
(loc)
12-14
12-14
10
l/defl
>999
>896
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 171 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-3-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-11-15 oc bracing.
REACTIONS. (size)2=0-3-8, 10=0-3-8
Max Horz 2=172(LC 11)
Max Uplift 2=-627(LC 12), 10=-627(LC 12)
Max Grav 2=1459(LC 19), 10=1459(LC 19)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2983/1257, 3-5=-2826/1222, 5-6=-1921/929, 6-7=-1921/929, 7-9=-2826/1222,
9-10=-2983/1257
BOT CHORD 2-16=-1052/2767, 14-16=-792/2204, 12-14=-798/2177, 10-12=-1058/2707
WEBS 6-14=-479/1220, 7-14=-682/392, 7-12=-204/709, 9-12=-311/260, 5-14=-682/392,
5-16=-204/709, 3-16=-311/260
NOTES-(7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 17-6-0, Exterior(2R)
17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 10.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T13
Truss Type
Hip
Qty
2
Ply
1
Job Reference (optional)
T22912235
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:16 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-dTGQbvzk61ePcD1bAhSd_CRSRiIBSxuzi9eUJ9zjeDb
Scale = 1:60.4
1 2
3
4 5 6
7
8 9
16 15 14 13 12 11 10
17
18 19 20 21
22
5x8 5x8
3x6
3x6
3x4
2x4
3x4
3x8
2x4
3x4
3x4
2x4
3x6
3x6
6-6-5
6-6-5
11-0-0
4-5-11
17-6-0
6-6-0
24-0-0
6-6-0
28-5-11
4-5-11
35-0-0
6-6-5
-1-0-0
1-0-0
6-6-5
6-6-5
11-0-0
4-5-11
17-6-0
6-6-0
24-0-0
6-6-0
28-5-11
4-5-11
35-0-0
6-6-5
36-0-0
1-0-0
0-4-14-11-10-4-14-11-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [4:0-5-12,0-2-8], [6:0-5-12,0-2-8], [8:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.63
0.79
0.27
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.24
-0.40
0.13
(loc)
13
13-15
8
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 174 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-5-12 oc bracing.
REACTIONS. (size)2=0-3-8, 8=0-3-8
Max Horz 2=-112(LC 10)
Max Uplift 2=-627(LC 12), 8=-627(LC 12)
Max Grav 2=1346(LC 1), 8=1346(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2774/1304, 3-4=-2308/1148, 4-5=-2465/1274, 5-6=-2465/1274, 6-7=-2308/1148,
7-8=-2774/1304
BOT CHORD 2-16=-1099/2488, 15-16=-1099/2488, 13-15=-844/2091, 11-13=-855/2091,
10-11=-1111/2488, 8-10=-1111/2488
WEBS 3-15=-479/302, 4-15=-123/385, 4-13=-225/578, 5-13=-401/295, 6-13=-225/578,
6-11=-123/385, 7-11=-479/302
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-0-0, Exterior(2R)
11-0-0 to 15-2-15, Interior(1) 15-2-15 to 24-0-0, Exterior(2R) 24-0-0 to 28-5-11, Interior(1) 28-5-11 to 36-0-0 zone; cantilever left and
right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 8.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T14
Truss Type
Hip
Qty
2
Ply
1
Job Reference (optional)
T22912236
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:17 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-5fqooE_MtLmGENcokPzsXPzYR6bgBLc6wpN1rbzjeDa
Scale = 1:60.4
1 2
3
4 5 6 7 8
9
10 11
16 15 14 13 12
17
18
19 20 21 22
23
24
4x6 3x6 4x6
3x6
4x6 3x8
2x4
3x4
3x4
3x4
3x8
2x4
4x6
3x6
9-0-0
9-0-0
17-6-0
8-6-0
26-0-0
8-6-0
35-0-0
9-0-0
-1-0-0
1-0-0
5-8-11
5-8-11
9-0-0
3-3-5
13-4-12
4-4-12
21-7-4
8-2-8
26-0-0
4-4-12
29-3-5
3-3-5
35-0-0
5-8-11
36-0-0
1-0-0
0-4-14-1-10-4-14-1-15.00 12
Plate Offsets (X,Y)-- [2:0-0-10,Edge], [10:0-0-10,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.94
0.96
0.49
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.29
-0.49
0.15
(loc)
14
12-14
10
l/defl
>999
>847
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 164 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
REACTIONS. (size)2=0-3-8, 10=0-3-8
Max Horz 2=93(LC 11)
Max Uplift 2=-627(LC 12), 10=-627(LC 12)
Max Grav 2=1346(LC 1), 10=1346(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2749/1326, 3-4=-2491/1193, 4-5=-2286/1140, 5-7=-2894/1400, 7-8=-2286/1140,
8-9=-2491/1193, 9-10=-2749/1326
BOT CHORD 2-16=-1126/2486, 14-16=-1225/2810, 12-14=-1215/2810, 10-12=-1138/2486
WEBS 3-16=-279/262, 4-16=-348/813, 5-16=-773/402, 7-12=-773/402, 8-12=-348/813,
9-12=-279/261
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0
to 13-4-12, Interior(1) 13-4-12 to 26-0-0, Exterior(2R) 26-0-0 to 30-2-15, Interior(1) 30-2-15 to 36-0-0 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 627 lb uplift at joint 2 and 627 lb uplift at
joint 10.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T15
Truss Type
HIP GIRDER
Qty
1
Ply
2
Job Reference (optional)
T22912237
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:21 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-_R3Jec1sxZHhi_wZzE2phF8FFj?P780irRLF_MzjeDW
Scale = 1:60.4
1 2
3 4 5 6 7 8
9 10
17 16 15 14 13 12 11
18 19 20 21 22 23 24 25 26 27 28
29 30 31 32 33 34 35 36 37 38
5x8 3x6 5x8
3x6
4x6 2x4
5x8
2x4
2x4
3x8
2x4
5x8 2x4
4x6
3x6
7-0-0
7-0-0
12-3-14
5-3-14
17-6-0
5-2-2
22-8-2
5-2-2
28-0-0
5-3-14
35-0-0
7-0-0
-1-0-0
1-0-0
7-0-0
7-0-0
12-3-14
5-3-14
17-6-0
5-2-2
22-8-2
5-2-2
28-0-0
5-3-14
35-0-0
7-0-0
36-0-0
1-0-0
0-4-13-3-10-4-13-3-15.00 12
Plate Offsets (X,Y)-- [3:0-5-12,0-2-8], [8:0-5-12,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.89
0.78
0.53
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.46
-0.72
0.16
(loc)
14
13-14
9
l/defl
>910
>582
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 325 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.1
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 7-0-3 oc bracing.
REACTIONS. (size)2=0-3-8, 9=0-3-8
Max Horz 2=74(LC 7)
Max Uplift 2=-1242(LC 8), 9=-1265(LC 8)
Max Grav 2=2686(LC 1), 9=2703(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6119/2707, 3-4=-7929/3617, 4-6=-7928/3617, 6-7=-7941/3637, 7-8=-7942/3637,
8-9=-6162/2764
BOT CHORD 2-17=-2377/5552, 15-17=-2381/5580, 14-15=-3820/8737, 13-14=-3820/8737,
11-13=-2434/5619, 9-11=-2429/5591
WEBS 3-17=-89/664, 3-15=-1225/2776, 4-15=-611/475, 6-15=-966/424, 6-14=0/480,
6-13=-939/400, 7-13=-603/468, 8-13=-1188/2734, 8-11=-89/663
NOTES-(11)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1242 lb uplift at joint 2 and 1265 lb uplift
at joint 9.
Continued on page 2
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T15
Truss Type
HIP GIRDER
Qty
1
Ply
2
Job Reference (optional)
T22912237
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:21 2021 Page 2 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-_R3Jec1sxZHhi_wZzE2phF8FFj?P780irRLF_MzjeDW
NOTES-(11)
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 130 lb down and 150 lb up at 7-0-0, 111 lb down and 147 lb up at
9-0-12, 111 lb down and 147 lb up at 11-0-12, 111 lb down and 147 lb up at 13-0-12, 111 lb down and 147 lb up at 15-0-12, 111 lb down and 147 lb up at 17-0-12, 111
lb down and 147 lb up at 17-11-4, 111 lb down and 147 lb up at 19-11-4, 111 lb down and 147 lb up at 21-11-4, 111 lb down and 147 lb up at 23-11-4, and 111 lb down
and 147 lb up at 25-11-4, and 189 lb down and 267 lb up at 28-0-0 on top chord, and 361 lb down and 152 lb up at 7-0-0, 85 lb down at 9-0-12, 85 lb down at 11-0-12,
85 lb down at 13-0-12, 85 lb down at 15-0-12, 85 lb down at 17-0-12, 85 lb down at 17-11-4, 85 lb down at 19-11-4, 85 lb down at 21-11-4, 85 lb down at 23-11-4, and
85 lb down at 25-11-4, and 361 lb down and 152 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of
the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-10=-54, 2-9=-20
Concentrated Loads (lb)
Vert: 3=-111(B) 5=-111(B) 8=-142(B) 17=-361(B) 11=-361(B) 18=-111(B) 19=-111(B) 21=-111(B) 22=-111(B) 23=-111(B) 24=-111(B) 25=-111(B) 27=-111(B)
28=-111(B) 29=-61(B) 30=-61(B) 31=-61(B) 32=-61(B) 33=-61(B) 34=-61(B) 35=-61(B) 36=-61(B) 37=-61(B) 38=-61(B)
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T16
Truss Type
Common Supported Gable
Qty
1
Ply
1
Job Reference (optional)
T22912238
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:22 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-Sddhry1VitPYK8UlXyZ2EThbh7WAsi_r455oWpzjeDV
Scale = 1:20.1
1
2
3
4
5
6
7
8
11 10 9
12
13
3x4 3x4
5x8 3x4 5x8 3x4 2x4
2x4
2x4
2x4
4x6
2x4
5-6-0
5-6-0
11-0-0
5-6-0
-1-0-0
1-0-0
5-6-0
5-6-0
11-0-0
5-6-0
0-4-12-3-120-4-15.00 12
Plate Offsets (X,Y)-- [2:0-3-13,Edge], [2:0-3-8,Edge], [8:0-3-8,Edge], [8:0-3-13,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.14
0.11
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
1
1
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 11-0-0.
(lb) - Max Horz 2=54(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 8, 10 except 2=-108(LC 12), 11=-116(LC 12), 9=-133(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 8, 2, 11, 10 except 9=259(LC 22)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 4-11=-174/304, 6-9=-183/330
NOTES-(10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-6-0, Corner(3R) 5-6-0
to 8-6-0, Exterior(2N) 8-6-0 to 11-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 10 except
(jt=lb) 2=108, 11=116, 9=133.
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T17
Truss Type
Common
Qty
3
Ply
1
Job Reference (optional)
T22912239
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:23 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-wpB43I27TBXPyI3y5f4HmgDhIXozb8F?JlqL2FzjeDU
Scale = 1:19.2
1
2
3
4
5
6
7
8
9
4x6
3x6 3x6
2x4
5-6-0
5-6-0
11-0-0
5-6-0
-1-0-0
1-0-0
5-6-0
5-6-0
11-0-0
5-6-0
0-4-12-7-90-4-15.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.47
0.33
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.04
-0.06
0.01
(loc)
4-5
4-5
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 39 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 8-6-11 oc bracing.
REACTIONS. (size)4=Mechanical, 2=0-3-8
Max Horz 2=61(LC 11)
Max Uplift 4=-169(LC 12), 2=-248(LC 12)
Max Grav 4=396(LC 1), 2=464(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-636/538, 3-4=-634/552
BOT CHORD 2-5=-407/531, 4-5=-407/531
WEBS 3-5=-33/253
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-6-0, Exterior(2R) 5-6-0
to 8-6-0, Interior(1) 8-6-0 to 10-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=169, 2=248.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T18
Truss Type
ROOF SPECIAL GIRDER
Qty
1
Ply
2
Job Reference (optional)
T22912240
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:24 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-O0lSGe3lEUfGZRe8eNbWJumlBx?BKRg8XPavbhzjeDT
Scale = 1:62.3
1 2
3 4 5 6 7 8
9
10
11 12
18 17 16 15 14 13
19 20 21
22 23
5x8 3x6 4x6
4x6
4x6
6x8 2x4 3x8
3x4
7x10
3x4
3x8
2x4
3x8
5x8
2x4
7-0-0
7-0-0
11-0-12
4-0-12
15-2-0
4-1-4
16-3-4
1-1-4
23-4-0
7-0-12
25-8-0
2-4-0
29-1-12
3-5-12
35-0-0
5-10-4
-1-0-0
1-0-0
7-0-0
7-0-0
11-0-12
4-0-12
12-5-5
1-4-9
16-3-4
3-9-15
19-8-12
3-5-8
23-4-0
3-7-4
25-8-0
2-4-0
29-1-12
3-5-12
30-0-2
0-10-5
35-0-0
4-11-14
36-0-0
1-0-0
0-4-13-3-14-2-120-4-13-3-15.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-2-11], [3:0-5-12,0-2-8], [14:0-4-12,0-5-0], [17:0-3-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.90
0.91
0.73
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.48
-0.75
0.13
(loc)
14-15
14-15
11
l/defl
>866
>559
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 396 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-10-12 oc bracing.
REACTIONS. (size)2=0-3-8, 11=0-3-8
Max Horz 2=96(LC 7)
Max Uplift 2=-1357(LC 8), 11=-1123(LC 8)
Max Grav 2=2904(LC 1), 11=2408(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6772/3050, 3-4=-9246/4271, 4-5=-10683/4904, 5-7=-10683/4904, 7-8=-7640/3501,
8-9=-5226/2388, 9-10=-5261/2387, 10-11=-5519/2503
BOT CHORD 2-18=-2695/6172, 17-18=-2695/6180, 15-17=-4105/9246, 14-15=-4113/9292,
13-14=-3335/7640, 11-13=-2208/5033
WEBS 4-15=-722/1642, 7-14=-2189/999, 8-14=-607/1400, 4-17=-1149/615, 3-17=-1727/3756,
5-15=-384/302, 7-15=-858/1885, 9-13=-1708/3810, 8-13=-4470/2086, 10-13=-284/224
NOTES-(11)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=5ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
6) Provide adequate drainage to prevent water ponding.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=1357, 11=1123.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 151 lb down and 147 lb up at
13-0-12, and 151 lb down and 147 lb up at 15-0-12 on top chord, and 889 lb down and 439 lb up at 11-0-12, 85 lb down at
13-0-12, and 85 lb down at 15-0-12, and 1388 lb down and 657 lb up at 16-3-4 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
Continued on page 2
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T18
Truss Type
ROOF SPECIAL GIRDER
Qty
1
Ply
2
Job Reference (optional)
T22912240
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:25 2021 Page 2 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-sCJqUz4N?on7BbDKC47ls5JwxLKQ3uwIm3KS77zjeDS
11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of
the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-9=-54, 9-12=-54, 2-11=-20
Concentrated Loads (lb)
Vert: 15=-1388(F) 17=-889(F) 20=-111(F) 21=-111(F) 22=-61(F) 23=-61(F)
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T19
Truss Type
Monopitch Girder
Qty
1
Ply
1
Job Reference (optional)
T22912241
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:25 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-sCJqUz4N?on7BbDKC47ls5J?LLRI33FIm3KS77zjeDS
Scale = 1:19.0
1
2
3456
3x4
3x4
3x4
4x6
7-0-0
7-0-0
7-0-0
7-0-0
0-4-13-3-15.00 12
Plate Offsets (X,Y)-- [1:0-1-9,Edge], [3:Edge,0-3-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.47
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.13
-0.21
0.00
(loc)
1-3
1-3
3
l/defl
>610
>392
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 31 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)1=0-3-8, 3=Mechanical
Max Horz 1=158(LC 7)
Max Uplift 1=-320(LC 8), 3=-419(LC 8)
Max Grav 1=718(LC 1), 3=909(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(9)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=320, 3=419.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 376 lb down and 189 lb up at
2-0-12, and 376 lb down and 189 lb up at 4-0-12, and 378 lb down and 187 lb up at 6-0-12 on bottom chord. The design/selection
of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54, 1-3=-20
Concentrated Loads (lb)
Vert: 4=-376(B) 5=-376(B) 6=-378(B)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T20
Truss Type
Monopitch Girder
Qty
1
Ply
1
Job Reference (optional)
T22912242
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:26 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-KOtChJ5?m6v_ploWmoe_OJr5MkjsoWVR?j30fazjeDR
Scale = 1:18.9
1
2
34563x4
3x4
4x10 MT20HS
7-0-0
7-0-0
7-0-0
7-0-0
0-4-13-3-15.00 12
Plate Offsets (X,Y)-- [1:0-3-9,0-1-8], [2:0-0-13,0-1-8], [3:0-5-0,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.93
0.77
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.21
-0.33
0.00
(loc)
1-3
1-3
3
l/defl
>382
>244
n/a
L/d
240
180
n/a
PLATES
MT20
MT20HS
Weight: 31 lb FT = 20%
GRIP
244/190
187/143
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x6 SP M 26
WEBS 2x4 SP No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-0-8 oc bracing.
REACTIONS. (size)1=0-3-8, 3=Mechanical
Max Horz 1=158(LC 5)
Max Uplift 1=-475(LC 8), 3=-637(LC 8)
Max Grav 1=1074(LC 1), 3=1408(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(10)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=475, 3=637.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 661 lb down and 313 lb up at
2-0-12, and 661 lb down and 313 lb up at 4-0-12, and 663 lb down and 311 lb up at 6-0-12 on bottom chord. The design/selection
of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54, 1-3=-20
Concentrated Loads (lb)
Vert: 4=-661(F) 5=-661(F) 6=-663(F)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T21
Truss Type
COMMON SUPPORTED GAB
Qty
1
Ply
1
Job Reference (optional)
T22912243
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:27 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-oaQavf5dWP1rQvNjKV9DxWOSi8DeXyZaDNpZC0zjeDQ
Scale = 1:34.2
1
2
3
4
5
6
7
8
9
10
11
12
19 18 17 16 15 14 13
20
213x4 3x4
5x8 3x4 5x8
3x4
4x6
5x6
9-4-0
9-4-0
18-8-0
9-4-0
-1-0-0
1-0-0
9-4-0
9-4-0
18-8-0
9-4-0
0-4-13-10-150-4-15.00 12
Plate Offsets (X,Y)-- [2:0-3-13,Edge], [2:0-3-8,Edge], [12:0-3-8,Edge], [12:0-3-13,Edge], [16:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.12
0.09
0.08
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
1
1
12
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 82 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 18-8-0.
(lb) - Max Horz 2=90(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 12, 17, 18, 15, 14 except 2=-106(LC 12), 19=-103(LC 12),
13=-122(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 12, 2, 17, 18, 19, 15, 14, 13, 16
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 10-13=-171/259
NOTES-(12)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 9-4-0, Corner(3R) 9-4-0
to 12-4-0, Exterior(2N) 12-4-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 17, 18, 15,
14 except (jt=lb) 2=106, 19=103, 13=122.
11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 12.
12) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T22
Truss Type
Common
Qty
3
Ply
1
Job Reference (optional)
T22912244
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:28 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-Hn_z6?6FHj9i23yvtCgSTkxYKYNfGNRkS1Y6kSzjeDP
Scale = 1:31.6
1
2
3
4
5
6
7
8
9 10
11
4x6
3x6 3x6 5x8
2x4 2x4
9-4-0
9-4-0
18-8-0
9-4-0
-1-0-0
1-0-0
5-11-10
5-11-10
9-4-0
3-4-6
12-8-6
3-4-6
18-8-0
5-11-10
0-4-14-2-110-4-15.00 12
Plate Offsets (X,Y)-- [7:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.45
0.87
0.23
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.15
-0.32
0.03
(loc)
6-7
6-7
6
l/defl
>999
>702
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 77 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-5-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-10-12 oc bracing.
REACTIONS. (size)6=Mechanical, 2=0-3-8
Max Horz 2=97(LC 11)
Max Uplift 6=-293(LC 12), 2=-369(LC 12)
Max Grav 6=681(LC 1), 2=747(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1249/821, 3-4=-972/647, 4-5=-973/658, 5-6=-1262/831
BOT CHORD 2-7=-682/1110, 6-7=-680/1126
WEBS 4-7=-362/599, 5-7=-344/365, 3-7=-326/350
NOTES-(8)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-4-0, Exterior(2R) 9-4-0
to 12-4-0, Interior(1) 12-4-0 to 18-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
6=293, 2=369.
8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T23
Truss Type
Common Supported Gable
Qty
1
Ply
1
Job Reference (optional)
T22912245
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:29 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-lzYLJL7u21HZgDX5RwBh0xTmZyvp?rythhIgGvzjeDO
Scale = 1:16.7
1
2
3
4
5
6
7
8
3x4 3x4
5x8 5x8 2x4
4x6
6-8-0
6-8-0
-1-0-0
1-0-0
3-4-0
3-4-0
6-8-0
3-4-0
7-8-0
1-0-0
0-4-31-8-40-4-36.00 12
Plate Offsets (X,Y)-- [2:0-4-0,0-3-1], [6:0-4-0,0-3-1]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.22
0.11
0.15
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
7
7
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 30 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
OTHERS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-8-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (size)2=6-8-0, 6=6-8-0, 8=6-8-0
Max Horz 2=-51(LC 10)
Max Uplift 2=-106(LC 12), 6=-106(LC 12), 8=-124(LC 12)
Max Grav 2=150(LC 21), 6=150(LC 22), 8=332(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-8=-157/358, 6-8=-157/358
WEBS 4-8=-276/496
NOTES-(10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=2ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-4-0, Corner(3R) 3-4-0
to 6-4-0, Exterior(2N) 6-4-0 to 7-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=106, 6=106, 8=124.
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T24
Truss Type
Common
Qty
2
Ply
1
Job Reference (optional)
T22912246
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:29 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-lzYLJL7u21HZgDX5RwBh0xTltyvp?tOthhIgGvzjeDO
Scale = 1:16.6
1
2
3
4
5
6
7
8
4x6
ST1.5x8 STP ST1.5x8 STP
3x4 3x4
2x4
3-4-0
3-4-0
6-8-0
3-4-0
-1-0-0
1-0-0
3-4-0
3-4-0
6-8-0
3-4-0
7-8-0
1-0-0
0-4-32-0-30-4-36.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.27
0.11
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.01
0.00
(loc)
2-6
2-6
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 27 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)2=0-8-0, 4=0-8-0
Max Horz 2=-60(LC 10)
Max Uplift 2=-178(LC 12), 4=-178(LC 12)
Max Grav 2=294(LC 1), 4=294(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-251/238, 3-4=-251/238
NOTES-(7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-4-0, Exterior(2R) 3-4-0
to 6-4-0, Interior(1) 6-4-0 to 7-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=178, 4=178.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T25
Truss Type
Hip Girder
Qty
1
Ply
1
Job Reference (optional)
T22912247
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:30 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-D96jXh8WpKPQHM6I?diwZ90vQMAqjJz1wL1DoLzjeDN
Scale = 1:22.8
1
2
3 4
5
6
8 7
4x6
ST1.5x8 STP ST1.5x8 STP
4x6
3x4 3x4
2x4 2x4
5-0-0
5-0-0
7-0-0
2-0-0
12-0-0
5-0-0
-1-0-0
1-0-0
5-0-0
5-0-0
7-0-0
2-0-0
12-0-0
5-0-0
13-0-0
1-0-0
0-3-151-11-150-3-151-11-154.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
NO
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.44
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.05
-0.09
0.02
(loc)
5-7
5-7
5
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-3-15 oc bracing.
REACTIONS. (size)2=0-8-0, 5=0-8-0
Max Horz 2=-35(LC 6)
Max Uplift 2=-326(LC 8), 5=-338(LC 8)
Max Grav 2=649(LC 1), 5=663(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1245/494, 3-4=-1142/493, 4-5=-1251/499
BOT CHORD 2-8=-393/1127, 7-8=-393/1142, 5-7=-398/1132
WEBS 3-8=0/256
NOTES-(10)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=326, 5=338.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 79 lb down and 105 lb up at
5-0-0, and 185 lb down and 249 lb up at 7-0-0 on top chord, and 110 lb down at 5-0-0, and 110 lb down at 6-11-4 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-6=-54, 2-5=-20
Concentrated Loads (lb)
Vert: 3=-60(B) 4=-138(B) 8=-66(B) 7=-66(B)
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
T26
Truss Type
Common
Qty
2
Ply
1
Job Reference (optional)
T22912248
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:31 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-hMg5k188aeXHvWgUZLD95MZ2mlXGSmBA8?nnLnzjeDM
Scale = 1:22.4
1
2
3
4
5
6
7
8 9
10
4x6
ST1.5x8 STP ST1.5x8 STP
3x6 3x6
2x4
6-0-0
6-0-0
12-0-0
6-0-0
-1-0-0
1-0-0
6-0-0
6-0-0
12-0-0
6-0-0
13-0-0
1-0-0
0-3-152-3-150-3-154.00 12
Plate Offsets (X,Y)-- [2:0-3-0,Edge], [4:0-3-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.50
0.37
0.10
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.05
-0.06
0.01
(loc)
2-6
4-6
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 43 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 8-0-1 oc bracing.
REACTIONS. (size)2=0-8-0, 4=0-8-0
Max Horz 2=41(LC 11)
Max Uplift 2=-264(LC 12), 4=-264(LC 12)
Max Grav 2=491(LC 1), 4=491(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-742/623, 3-4=-742/622
BOT CHORD 2-6=-469/649, 4-6=-469/649
WEBS 3-6=-10/262
NOTES-(7)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-0-0, Exterior(2R) 6-0-0
to 9-0-0, Interior(1) 9-0-0 to 13-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=264, 4=264.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
V02
Truss Type
Valley
Qty
2
Ply
1
Job Reference (optional)
T22912249
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:31 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-hMg5k188aeXHvWgUZLD95MZ_3lXfSnkA8?nnLnzjeDM
Scale = 1:13.1
1
2
3
4
2x4
2x4
2x4
5-0-0
5-0-0
0-0-42-1-05.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.74
0.34
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)1=4-11-6, 3=4-11-6
Max Horz 1=97(LC 9)
Max Uplift 1=-62(LC 12), 3=-69(LC 12)
Max Grav 1=152(LC 1), 3=152(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-10-4 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
6904 Parke East Blvd.
Tampa, FL 36610
Job
WS0020
Truss
V03
Truss Type
Valley
Qty
2
Ply
1
Job Reference (optional)
T22912250
8.430 s Feb 12 2021 MiTek Industries, Inc. Fri Feb 19 07:50:32 2021 Page 1 Builders FirstSource (Lady Lake, FL), Lady Lake, FL - 34472,
ID:YHWDr0mBnrebqkOSNfKX?FyquAG-9YETyN9mLyf8XgFg62lOea5Ic9w_BE_JNfWKtDzjeDL
Scale = 1:9.0
1
2
3
2x4
2x4
2x4
3-0-0
3-0-0
0-0-41-3-05.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
7.0
0.0 *
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.25
1.25
YES
FBC2020/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.17
0.08
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
244/190
LUMBER-
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size)1=2-11-6, 3=2-11-6
Max Horz 1=50(LC 11)
Max Uplift 1=-32(LC 12), 3=-35(LC 12)
Max Grav 1=78(LC 1), 3=78(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-(7)
1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any
particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code."
This item has been
electronically signed and
sealed by Lee, Julius, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
February 19,2021
PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3
-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths