Loading...
HomeMy WebLinkAboutAerial Precast Concrete & Structural SteelCHARETTE RESIDENCE 664 SE HIDDEN RIVER DRIVE, PORT ST LUCIE, FL 34983 AERIAL PRECAST CONCRETE & STRUCTURAL STEEL MDP ENGINEERING State of Florida CA #6918 Registered Engineer #32563 1 (954) 243-4595 i CHARETTE RESIDENCE 664 SE HIDDEN RIVER DRIVE, PORT ST LUCIE, FL 34983 INDEX TITLE...............................................................................................1 INDEX.............................................................................................2 JOISTCALC...................................................................................3 ..%0jD%pIETg6 ,��li ��i���� No - •w- do 49 i _ •2� /llllltlt�, AERIAL PRECAST CONCRETE, LLC 3200 BURRIS ROAD AERIAL PRECAST CONCRETE T 964.321-0200AVIEp AF 954 321-0093 --- U�{UgpL STEEL JOIST CALC= of X 1111104 UPS 664 SE HIDDEN RIVER DRIVE, Date: 0a103120 IT ST LUCIE, FL 34983 (2ND Design: T.D.Y. Date: FLOOR) Checked: Fuat Omarli, P.E. P o rammed by: & STR 1gEWNL FL000. SHOP OWG5IRF•101mChetatte RnkWc"PCC8MUcWC*q 43"S."' FLOOR)'I"4pn+P Ll51ap Oraxi"YS INPUT JOIST NO SPAN SLAB WIDTH JOIST DEPTH SERVICE DEAD LOAD SERVICE LIVE LOAD 1 J1-D17 5.25' (2ND. F_ LOOR)-.-. Manual input governs-> 5.250 5.25 t WIND LOAD(grosS Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net UPlift) Fy (BOTr. ANGLES) F,' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM ACH ND CHORD ) Ar,,. 'd= Max(Tu10.9'Fy As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS Gravity) REACTION DUE TO UNIFORM LOAD( REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) - Diagonal Length 4.0 Ft j 17" Uniform 80 96 PSf 50 80 Psf Tension bar END DID - tan(d124") = 35,31 DESIGN r 9 P2 P3 P, I i 1:=Q3 ♦ 0, Q2 t 1.85 k DL+LL 1.85 k x2 1.01 k DL+Wind 1.01 k lied at to Dist From left supaoft Pointe S P,: P3: Pointe S 384 Pit Q1' 50 Ksi Q2' 3 Ksi Q3' @ MIDSPAN Applied at bott. Dist From left suppo� 2205 Ft-Lbs 1556 Lbs 0.035 in2 OK-n2 2L-1x1x1/8 --- `NONE 1848 Lbs 1008 Lbs 19.04 in p, - arc 1.12k F=(R Vo)lsin a= 0.65 k 10.578 = 0.56 136.0 = As=F1 PAO.60 fy)) = MAX, MARK DEPTH BASE qTY 17 in 5.3 Ft 1 J1-D17 5.26 2ND FLOOR . END V1 BOTTOM CHORD TOP CHORD DIAGONAL 112" nn116LE ANGLES DOUBLE ANGLES (2) V2 2L 1x1x118 — •) Use the same up to the centedne °IL •) Symmetrical configuration shall apply, after the centerline Abre NIG= Not Good J1 D17 = JOIST N0.1 JOIST DEPTH Sp J1 D17 = GIRDER JOIST 0.35 k 10.58 = 0.61 k F(wind case)- (2) V2 0.02 in2 ie: J1D17 ie: SPJ1D1 i (SP INDICATES SPECIAL JOIST) REMAI vs AERIAL PRECAST CONCRETE, LLC 3200 BURRIS ROAD AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 ' a F RUc ALVTSE , T 954-321-0200 • F 954-321-0093 LlShap DraWnps%AERIAL FLOOR SHOP DWGSL4F-20201Chme"a ResideeroNPC CakslJeislCakl(2'JIOI7r(2ND FLOOR- SALCONY13bIGrariry De Ign INPUT JOIST NO 2-J1-D17 8' (2ND FLOOR - BALCONY). SPAN Manual input governs--> 8.000 58 v t SLAB WIDTH 4.0 Ft JOIST DEPTH 117" v Uniform SERVICE DEAD LOAD 80 95 Psf SERVICE LIVE LOAD 100 160 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL 1024 Pif TOTAL LOAD=DL-WL( Negative =Net Uplift) 384 Plf Fy (BOTT. ANGLES) 50 Ksi F,' 3 Ksi DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD AsmCd= Max(Tu10.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar 664 SE HIDDEN RIVER DRIVE, JOIST CALC 2 of x 11/1/04 UPDATE PORT ST LUCIE, FL 34983 (2ND Design: T.D.Y. Date: 08/03120 FLOOR) Checked: Date: DESIGN PLANET Programmed by: Fuat Omarli, P.E. P1 P2 P3 1 1 1 QI Q2 Q3 DL+LL 4.10 k x2 f 4.10 k DL+Wind 1.54 k 1.54 k Point Loads Applied at top Dist. From left support Pr' -- P2: P3: . Point Loads Applied at bolt. Dist. From left support Qr' I- - Q3: @ MIDSPAN 8018 Ft-Lbs 5660 Lbs 0.126 in2 OK 2L lxlxl/8 As=0.46 i n2 NONE-- — --- — — - a = arctan(d/ 24") = 35.31 F=(R-Vo)Isin a= 2.35 k If 0.578 = 4.06 k A.—r=i r mn an f Al - 2.03 / 36.0 = QTY - - ... MARK DEPTH MAX. BASE 2'J1-D178'(2NDFLOOR -BALCONY).' 17in 8.0Ft 4096 Lbs 1536 Lbs 4096 Lbs 19.04 in F(wind case)= 0.88 k 10.58 = 1.52 k 0.06 in2 (2) 112 C/L BOTTOM CHORD TOP CHORD END V1 V2 V3 V4 V5 I V6 I REMAING I DOUBLE ANGLES DOUBLE ANGLES DIAGONAL 1 I Vs 2L-1xlx1/8 NONE (2) 1/2 1 518" *) Use the same up to the centedne," /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 D17 = GIRDER JOIST ie: SPJ1D1 i (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE, JOIST CALL 3 of x % 3200 BURRIS ROAD 11/1/04 UPDATE CERIALPRECGST CONCRETE I PORT ST LUCIE, FL 34983 (2ND DAVIE, FLORIDA 33314 Design: T.D.Y. Date: 08/03/20 ME _ T 954-321-0200 • F 954-321-0093 FLOOR) Checked: Date: ZLSt+y DrMngsUERIAL FLOOR SNOP DWGSVIF•202Mxe"a ResidmcelAPC CeksUdst Cekg3J1-0175.75(!NDFLOO1QAs]G *On* INPUT JOIST NO 3 J1-D17 8.75' (20.FLOOR)_ SPAN Manual input governs--> 8.750 ; 8.75 V t SLAB WIDTH 4.0 Ft r JOIST DEPTH 17" V Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL(Negative =Net Uplift) Fy (1107. ANGLES) F, DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD A, q'd= Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar 704 Plf 384 Plf 50 Ksi 3 Ksi UE_0iU11ir LAItlL I 1 IVU. a111111Y. wu• v...... .., .� P, P2 P3 1 1 1 Qr Q2 Q3 DL+LL 3.08 k x2 t 3.08 k DL+Wind 1.68 k 1.68 k Point Loads Applied at top Dist. From left support PI: I P2. -- P3: , Point Loads Applied at butt. Dist. From left support Qr: I- --- w Q2: Q3: @ MIDSPAN 6414 Ft-Lbs 4528 Lbs 0.101 in2 OK 12L-1x1x1/8 -- As=0.46 -w n2 NE a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 1.88 k / 0.578 = 3.25 k As=F/ f2x10-60 full = 1.62 / 36.0 = Mom' QTY MARK DEPTH BASE 3 J1-D17 8.75' (2ND FLOOR). 17 in 1 8.8 Ft 3080 Lbs 1680 Lbs NVVV - 19.04 in F(wind case)= 1.02 k 10.58 = 1.77 k 0.05 in2 (2) 112 Y BOTTOM CHORD TOP CHORD END V1 V2 V3 V4 V5 V6 I REMAING DOUBLE ANGLES DOUBLE ANGLES DIAGONAL I I V's 2L-1x1x118 NONE (2) 1/2 1 5/8" *) Use the same up to the centerine, /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 D17 = GIRDER JOIST ie: SPJ1D1 i (SP INDICATES SPECIAL JOIST) • JOIST CALC 4 of X AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE, 1111104 UPDATE % 3200 BURRIS ROAD PORT ST LUCIE, FL 34983 (2ND PREC/L`.T CONCRET AERIALE DAVIE, FLORIDA 33314 Design: T.D.Y. Date: 08/03120 6 STRUCTURALSTEEL T 954-321-0200 - F 954-321-0093 FLOOR) Checked: Date: , e urT n-........,,.......1 L..• G,n1 Il—rli D G Lm* (k.ApiAERIAL FLOOR SHOP DV&MF•202NChQett, Rest —d4PC Cd.Uoist Cekg4 XW710.5(WO FLOOR)..hjG,,&r Design INPUT JOIST NO 4 J1-D1710.5' (2ND, FLOOR), -- SPAN Manual input governs—> j 10.500 1.10.5 V t SLAB WIDTH _ 4.0 Ft JOIST DEPTH rl7" V Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL(Negative =Net Uplift) Fy (BOTT. ANGLES) Fc' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD ASfeQ'd= Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar 704 Plf 384 Plf 50 Ksi 3 Ksi P, P2 P3 1 1 l ♦ Q1 Q2 Q3 DL+LL 3.70 k ( x2 t 3.70 k DL+Wind 2.02 k 2.02 k Point Loads Applied at top Dist. From left support PI: �— P2: I . P3: I ' Point Loads Applied at bott. Dist. From left support Qj: Q2. Q3: @ MIDSPAN 8768 Ft-Lbs 6189 Lbs 0.138 in2 OK ( 2L-lxlxl/8 As=0.46 ^ w n2 ONE a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 2.49 k / 0.578 = 4.31 k Aq=Fr r9xrn.sn fvu = 2.16 / 36.0 = QTY MARK DEPTH MAX. BASE 4 J1-D17 10.5'(2ND FLOOR). I 17 in 10.5 Ft 3696 Lbs 2016 Lbs OWL) LU.7 19.04 in F(wind case)= 1.36 k / 0.58 = 2.35 k 0.06 in2 (2) 112 BOTTOM CHORD TOP CHORD END V1 V2 V3 V4 V5 V6 REMAING DOUBLE ANGLES DOUBLE ANGLES DIAGONAL �s 2LAAA18 NONE (2) 1/2 1 5/8" 1/2" *) Use the same up to the centedne, /L *) Symmetrical configuration shall apply, after the centerline Abreviation: NIG= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 D17 = GIRDER JOIST ie: SPJ1D11(SP INDICATES SPECIAL JOIST) L AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE, JOIST CALL 5 Of X 11/1/04 UPDATE PC 3200 BURRIS ROAD I kERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 PORT ST LUCIE, FL 34983 Design: T.D.Y. Dale: 08/03/20 STRUCMRALSTEEL • T 954-321-0200 • F 954-321-0093 (BALCONY) Checked: Date: Z%Shop Ora.*IAERIAL FLOOR SHOP M WF-20201Charetle RmidemIAPC Cek%Uuisl Cek115-A-D179.6(BALCONY)YBIC *Design INPUT JOIST NO 5—J1-D17 9.5' (BALCONY)..--_ SPAN Manual input governs—> 9.500 9-5 'w I SLAB WIDTH 4.0 Ft JOIST DEPTH 17" v Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 100 160 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL 1024 Plf TOTAL LOAD=DL-WL( Negative =Net Uplift) 384 Plf Fy (BOTT. ANGLES) 50 Ksi Fc' 3 Ksi DESIGN OF BOTTOM CHORD Lj IYr L/1114LI 1 Ivy. v1.. �.... ..........., .- P1 P2 P3 1 1 1 4 QI Q2 Q3 DL+LL 4.86 k x2 4.86 k DL+Wind 1.82 k 1.82 k Point Loads 43plied at top Dist. From left support PI: P3. i -- - Point Loads Applied at bott. Dist. From left support Q1' (-- Q2: Q V 3• � @ MIDSPAN MAX. MOMENT 10642 Ft-Lbs TENSION AT BOTTOM CHORD 7512 Lbs ASrgd= Max(Tu/0.9'Fy AND Tu/0.75'Fu) 0.167 in2 OK As (2L's) 2L ixixi/8— -- As=0.46 .r n2 TOP CHORD I NONE DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) 4864 Lbs REACTION (DL+Wind) 1824 Lbs LEFT REACTION due to point load " RIGHT REACTION due to point load TOTAL REACTION (Max.) 4864 Lbs Diagonal Length 19.04 in END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 3.11 k / 0.578 = 5.39 k F(wind case)= 1.17 k 10.58 = 2.02 k As=Fi 0XIO Rn full = 2.69 / 36.0 = 0.07 in2 (2) 112 MAX. QTY MARK DEPTH BASE 5—J1-D17 9.5' BALCONY . 17 in 9.5 Ft BOTTOM CHORD TOP CHORD END V1 V2 V3 V4 V5 V6 REMAING DOUBLE ANGLES DOUBLE ANGLES DIAGONAL V'S 21-AxW/8 NONE (2) 112 1 5/8" ') Use the same up to the centedne, /L ') Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: A D17 SP J1 D17 = GIRDER JOIST le: SPA D1 i (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE, JOIST CALL s or x tvvoa UPDATE /A 3200 BURROAD PORT ST LUCIE 'aERIALPRECAST CONCRETE DAME, FLORIDAR , FL 34983 33314 , Design: T.D.Y. Date: 08/03/20 a STf7uGRJRALSTEEL_ T954-321-0200 • F 954-321-0093 (BALCONY) Checked: Date: 7%Shop Oreab9MAERIAL FLOOR SHOP OWGSNF-202BIChweUe Resid=e%APCCeksVdstC*gS-J1-017125(BALCONYP15113r AY Oe$0 INPUT JOIST NO 6—J1-D1712.5' (BALr CONY)_- SPAN Manual input governs--> 12.500 112.5 'q' t SLAB WIDTH 4.0 Ft JOIST DEPTH 17" Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 100 160 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL 1024 Plf TOTAL LOAD=DL-WL( Negative =Net Uplift) 384 Plf Fy (eOTr. ANGLES) 50 Ks! FG' 3 Ksi DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD AS f,,'d = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 4.65 k / 0.578 = As=F/ r2wo.6o full = LICJR7141-1J11VC I r I U91 C.11111 ICU Uy. 1 UGIL V111011111 .1.. P1 P2 P3 1 1 l * Q, Q2 Q3 DL+LL 6.40 k x2 t 6.40 k DL+Wind 2.40 k 2.40 k Point Loads Applied at top Dist. From left support Pj: , I P3: v Point Loads (Applied at bolt. Dist. From left support Qj: Q2: _ Q3: @ MIDSPAN 19154 Ft-Lbs 13520 Lbs 0.300 in2 OK j 2L-lxlxl/8 As=0.46 7 n2 NONE 6400 Lbs 2400 Lbs .1.. 19.04 in 8.05 k F(wind case)= 1.74 k 10.58 = 3.02 k 4.02 / 36.0 = 0.11 in2 (2) 112 MAX. QTY MARK DEPTH BASE 6—J1-D1712.5' (BALCONY). 17 in 12.5 Ft BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-txtxt/8 ONE (2) 1/2 1 3/4" 1/2" *) Use the same up to the centedne, /L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST le: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE, JOIST CALL 7 of X APIC 3200 BURRIS ROAD 1 1111/04 UPDATI 4ERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 ! PORT ST LUCIE, FL 34983 (2ND Design: T.D.Y. Date: 08/03/20 L.a s�tuca RALsTEEL .,_ T 954-321-0200 • F 954.321-0093 FLOOR) Checked: Date: MhoP ftwinp%AERIAL FLOOR SHOP OWGSIAF402MCh—He Rftld rc lAPC CaksUdst r.*VJ2-0t720.75(2ND FLOOR).rislG+evfty DesiT INPUT JOIST NO 7 J2-D17 20.75' (2ND FLOOR). SPAN Manual input governs—> 20.750 ; Z�_ 0.75 w t SLAB WIDTH _ 4.0 Ft JOIST DEPTH 1 17" Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (1307. ANGLES) Fc' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD ASf.q'd= Max(Tu10.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length 704 Plf 384 Plf 50 Ksi 3 Ks! ur-oiG NrL.ANEI rIU91d111111CU Uy. FUCIL WHICH III r.L PI P2 P3 1 1 1 * Q, Q2 Q3 DL+LL 7.30 k x2 t 7.30 k DL+Wind 3.98 k 3.98 k Point Loads Applied at top Dist. From left support Pj: P2. r.-_ .► Point Loads Applied at bolt. Dist. From left support Q1: Q2: _ Q3: @ MIDSPAN 36139 Ft-Lbs 25510 Lbs 0.567 in2 OK 21--1.5 X 1.5 X 1/8 ;NONE END DIAGONAL Tension bar a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 6.10 k / 0.578 = 10.56 k As=F/ 12xf0.60 fv11= 5.28 / 36.0 = MAX. QTY MARK DEPTH BASE 7 J2-D17 20.75' 2ND FLOOR). 17 in 20.8 Ft 7304 Lbs 3984 Lbs 7304 Lbs 19.04 in As=0.71 w F(wind case)= 3.33 k / 0.58 = 5.76 k 0.15 in2 (2) 1/2 BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 I REMAING V's 21--1.5 X 1.5 X 1/8 NONE (2) 1/2 1 3/4" 3/4" 5/8" ') Use the same up to the centedne, /L ') Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1 D17 SP J1 D17 = GIRDER JOIST ie: SPJ1 D1 i (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLCM 664 SE HIDDEN RIVER DRIVE, JOIST CALC 8 of X 3200 BURRIS ROAD PORT ST LUCIE 11/1104 UPDATE 4ERIAL PREC/lST CONCRETE DAVIE, FLORIDA 33314 , FL 34983 (2ND & STRUCTURALSTEEL i FLOOR) Design: T.D.Y. Dale: 08103120 — A T 954-321-0200 - F 954-321-0093 Checked: Date: 21Shcp @"ningMERNL FLOOR SHOP MSM-202010mefte ResidmelAPC CaksUoist Ce1cg8 J3-D17 23.25 (2ND FLOOR)..Is)Gw'ty DOO INPUT JOIST NO 8 J3-D17 23.25' (2ND FLOOR). SPAN Manual input governs—> 23.250 123.25 w t SLAB WIDTH 4.0 Ft JOIST DEPTH 17 —w Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL 704 Plf TOTAL LOAD=DL-WL( Negative =Net Uplift) 384 Plf Fy (BOTT. ANGLES) 50 Ksi F,' 3 Ksi DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD As rey'd = Max(Tu/0.9*Fy AND Tu/0.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar utbi(jNyLANtI rrogrammea Dy: ruaL Vindiii, I-X. P, P2 P3 1 1 1 Qj Q2 Q3 DL+LL 8.18 k x2 T 8.18 k DL+Wind 4.46 k 4.46 k Point Loads Applied at top Dist. From left support Pj: P2: �► . Point Loads Applied at bolt. Dist. From left support r QI: V . Q2. — Q3: @ MIDSPAN 45794 Ft-Lbs 32325 Lbs 0.718 in2 OK j 2L- 11/2 x 11/2 x 3/16 As=1.054 ;NONE 8184 Lbs 4464 Lbs 8184 Lbs 19.04 in a = arctan(d/ 24") = 35.31 F=(R-Vo)/sin a= 6.98 k 10.578 = 12.08 k A-z=F/ r9xfa9n fvu = 6.04 / 36.0 = MAX' QTY MARK DEPTH BASE 8 J3-D17 23.25' 2ND FLOOR). 17 in 23.3 Ft w n2 F(wind case)= 3.81 k / 0.58 = 6.59 k 0.17 in2 (2) 112 Y BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-1 1/2 x 1 1/2 x /16 A NONE (2) 1/2 1 7/8" 3/4" 518" 1/2" *) Use the same up to the centedne,-/L *) Symmetrical configuration shall apply, after the centerline Abreviation: N/G= Not Good J1 D17 = JOIST NOJ JOIST DEPTH ie: J1D17 SP J1 D17 = GIRDER JOIST ie: SPJ1 D17 (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC 664 SE HIDDEN RIVER DRIVE,. JOIST CALC 9 of XAX NCRETEn/oa UPDATE 3200 BURROAD PORT ST LUCIE FL 34983 (2ND AERIAL PRECAST OODAVIE, FLORIDAFLOROR IDA 33314 ' Design: T.D.Y. Date: 08103120 & STRUC:TURALSTEEL7 T 954-321-0200 • F 954-321-0093 FLOOR) Checked: Date: MShap WWw p IAERIRL FLOOR SHOP DWGSAF-20201Chsrt1e R.1d..*APC CaIc UcW C*qg SPJ1.015 E' (2ND FLOORI.)ds1G*�2 Desigl INPUT JOIST NO 9 SPJ1•1315 8' (2ND, FLOOR)__-. SPAN Manual input governs—> 8.000 8 'w t SLAB WIDTH 4.0 Ft JOIST DEPTH I5" w Uniform SERVICE DEAD LOAD 105 126 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy (1307. ANGLES) Fc' DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD As,,,q,d= Max(Tu10.9*Fy AND Tu/0.75*Fu ) As ( 212s ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load • RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length END DIAGONAL Tension bar a = arctan(dl 24") = 32.01 F=(R-Vo)/sin a= 1.96 k 10.530 = Ac=F/ r2wo-Rn fv11= 824 Plf 504 Plf 50 Ksi 3 Ks! DESIGNPLANET Programmed by: Fuat Ornadi, P.E. Pt P2 P3 1 b l Qt Q2 Q3 DL+LL 3.30 k x2 f 3.30 k DL+Wind 2.02 k 2.02 k Point Loads Applied at top Dist. From left support Pt: . r P3: w Point Loads Applied at bolt. Dist. From left support Q7: Q2: _ Q3: @ MIDSPAN 6360 Ft-Lbs 5088 Lbs 0.113 in2 OK 2L-lxlxl/8 --- - As=0.46 - w n2 NONE 3296 Lbs 2016 Lbs 3296 Lbs 16.50 in 3.69 k F(wind case)= 1.20 k 10.53 = 2.26 k 1.85 136.0 = 0.05 in2 (2) 112 MAX. QTY MARK DEPTH BASE 9 SPJ1-D15 8' (2ND FLOOR). 15 in 8.0 Ft BOTTOM CHORD DOUBLE ANGLES TOP CHORD DOUBLE ANGLES END DIAGONAL V1 V2 V3 V4 V5 V6 REMAING V's 2L-txtxl/8 NONE (2) 112 5/8" *) Use the same up to the centedne,"/L *) Symmetrical configuration shall apply, after the centerline Abreviation: NIG= Not Good J1 D17 = JOIST NOJ JOIST DEPTH le: J1D17 SP J1 D17 = GIRDER JOIST ie: SPJ1D11(SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC APIC 3200 BURRIS ROAD AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 2: STRUGTUFIALEEL .� T 954-321-0200 F 954-321-0093 ST JOIST CALC 10 of X 664 SE HIDDEN RIVER DRIVE, 1111104 UPDATE PORT ST LUCIE, FL 34983 (2ND Design: T.D.Y. Date: 08103120 FLOOR) Checked: Date: nshcp Om h,'AERIAL FLOOR SHOP OWOSIAF-20201ChereRe RaMe— ARC Cekslldsl CekgI0 SPJ1A1710.W (2ND FLOOR)AN01 4 DO INPUT JOIST NO 10 SPJ1-D1710.50' (2ND FLOOR). SPAN Manual input governs—> 10.500 10.5 v t SLAB WIDTH _ 4.0 Ft JOIST DEPTH 117 Uniform SERVICE DEAD LOAD 80 96 Psf SERVICE LIVE LOAD 50 80 Psf WIND LOAD(gross Uplift) TOTAL LOAD=DL+LL TOTAL LOAD=DL-WL( Negative =Net Uplift) Fy IBM. ANGLES) Fr DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD A,,ad= Max(Tu10.9*Fy AND Tu10.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length 704 Plf 384 Plf 50 Ksi 3 Ks! DESIGNPLANET Programmed by: Fuat Omadi, P.E. P1 P2 P3 1 1 l , Qt Q2 Q3 DL+LL 4.23 k x2 4.k DL+Wind 2.55 k 2.81 k Point Loads Applied at top Dist From left support P1: 1.33KINode 5 wl 6.25Ft 3• i Point Loads ott• Dist From left support Q{ jApplie� Qr I ----- Q3: I �• j @ MIDSPAN 12130 Ft-Lbs 9350 Ft-Lbs 8563 Lbs 0.190 in2 OK 1 2L-lxlxl/8 J As=0.46 --- n2 NONE 3696 Lbs 2016 Lbs 538 Lbs � 791 Lbs Lbs <—Max. shear, controls 4487 Lbs 19.04 in END DIAGONAL Tension bar a = arctan(dl 24") = 35.31 F=(R-Vo)Isin a= 3.03 k 10.578 = 5.24 k As=FI (20.60 Ml = 2.62 1 36.0 = MAX. Y MARK DEPTH BASE PQTE 10 SPJ1-D17 10.50'(2ND FLOOR). 17 in 10.5 Ft CHORD TOP CHORD END ANGLES IDOUBLE ANGLES DIAGOI *) Use the same up to the centerine,"IL *) Symmetrical configuration shall apply, after the centerline Abreviation: NIG= Not Good J1 D17 = JOIST NO.1 JOIST DEPTH SP J1 D17 = GIRDER JOIST F(wind case)= 1.90 k 10.58 = 3.28 k 0.07 in2 (2) V2 AIL V2 V3 V4 V5 V6 REMAING Vs ie: J1D17 ie: SPJ1D1 t (SP INDICATES SPECIAL JOIST) AERIAL PRECAST CONCRETE, LLC APIC 320013URRIS ROAD AERIAL PRECAST CONCRETE DAVIE, FLORIDA 33314 RucTURALSTEEI T 954-321-0200 • F 964.321-0093 fzm JOIST CALC of X 664 SE HIDDEN RIVER DRIVE, 11/1104 UPDATE PORT ST LUCIE, FL 34983 (2ND Design: T.D.Y. Date: 06103/20 FLOOR) Checked: Date: E ZISh.P Om bg,%AER1AL FLOOR SHOP DyJOW40201CI,aeNe Re ideme%APC Cek5Udsl CdcU11 SPJ1017 27.25 (1ND FLOOR).><h)Grovil, Design INPUT 11 SPJ3-D17 23.25' (2ND FLOOR . JOIST NO SPAN Manual input governs—> 23.250 ; 23.25 ' t 4.0 Ft SLAB WIDTH --- JOIST DEPTH 117 Uniform 174 209 Psf SERVICE DEAD LOAD 50 80 Psf SERVICE LIVE LOAD WIND LOAD(gross Uplift) 1 TOTAL LOAD=DL+LL 835 Plf TOTAL LOAD=DL-WL( Negative =Net Uplift) 50 Ksi Fy (BOTT. ANGLES) 3 Ksi F� DESIGN OF BOTTOM CHORD MAX. MOMENT TENSION AT BOTTOM CHORD AS re# = Max(Tu10.9*Fy AND Tu10.75*Fu ) As ( 2L's ) TOP CHORD DESIGN OF WEB DIAGONALS REACTION DUE TO UNIFORM LOAD(Gravity) REACTION (DL+Wind) LEFT REACTION due to point load RIGHT REACTION due to point load TOTAL REACTION (Max.) Diagonal Length DESIGNPLANET Programmed by: Fuat Ornarfl, P. . PI P2 P3 QI Q2 Q3 x2 13.43 k DL+LL 13.43 k 9.71 k DL+Wind 9.71 k Point Loads ApplieDist support. left suort P1: P3: Point Loads at bolt• Dist From left support Q{ (Applied Q2. L--._.__---- Q3• @ MIDSPAN 75144 Ft-Lbs 53043 Lbs 1.179 in2 OK _ --- — -------As=1.876 .r n2 I2L-2X2X1/4 — ---- ----- ---- ------ - INONE 13429 Lbs 9709 Lbs 13429 Lbs 19.04 in ENDDDITension bar a = arctan(dl 24") = 35.31 F(wind case)= 8.28 k 10.58 = 14.33 k F=(R-Vo)/sin a= 11.46 k 10.578 = 19.82 k (2) 518 9.91 1 36.0 = 0.28 in2 As=FI [2x(0.60 fy)) = MAX OIL QTY MARK DEPTH BASE 11 SPJ3-D17 23.25' (2ND FLOOR). 17 in BA Ft V2 V3...... .............. i V4 V5 V6 REMAING 30TTOM CHORD TOP CHORD END V1 V's DOUBLE ANGLES DOUBLE ANGLES �DIAZONAL82L-2X2X114 NONE *) Use the same up to the centedne °IL *) Symmetrical configuration shall apply, after the centerline Abre=iation'. NIG= Not Good J1 D17 = JOIST NO.I JOIST DEPTH SP J1 D17 = GIRDER JOIST 1" 3/4" le: J1D17 le: SPJ1D1 i (SP INDICATES SPECIAL JOIST)