HomeMy WebLinkAboutCertification for Design Load Compliance1 Planning & Development Services Department
COUNTY Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Charette Residence
Project Address:_ 633 SE Hidden River Dr Port St Lucie, FL 34983
Permit #: Occupancy Type: R3 Construction Type: vb
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
1y o Any accessory structure requiring a building permit
o Any non-residential structure.
�( * Note: Form not required for interior renovations provided that no exterior structural elements are affected and
a certain minor building permits at the discretion of the local building official. Contact the #above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FbC 2017 Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed Open
3. Risk Category:_1 X II III IV Exposure Category: B X C D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: 5 ft
5. Mean Roof Height 25 ft Roof Pitch: 4 :12 Parapet: 1 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
,. +-40 +-50 +-55
„a Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor:70 PSF Roof/Dead: 15 PSF Roof/Live:20 Balcony:70 PSF
70 50 250
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, toAhe-best,of my knowledge and belief, the attached plans & specifications have been designed to
comply wit' `�" a icab uctural portions of the building codes currently adopted and enforced by St. Lucie
� County:` ,aG�eltttfy thatostr al elements depicted on these plans provide adeqjEft resistance to the design
forces d: �� E `�
Paul Charette �'
t°
o 7 17 %
Signatur , te9an66
0
Print Name
Ar 0016279
Cert # & Co jVh.
Charette international Architecture 2528 n 38 th a%
Company Name & Address
Revised 12/07/2018