HomeMy WebLinkAboutNOA; Firestone UltraPly TPO SA Single Ply Roof Systems over Concrete DecksMIAMktaADE MIAMI-DADE COUNTY
LWAUMM o PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
( � NOTICE OF ACCEPTANCE (NOA) WWW.miamidade.sov/economy
Firestone Building Products Company, LLC
200 4th Ave. South
Nashville, TN 37201
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve
the right to have this product or material tested for quality assurance purposes. If this product or material
fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the
AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Firestone UltraPly TPO SA Single Ply Roof Systems over Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
v r
`6 _ followed by the expiration date may be displayed in advertising literature., If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 96.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
MIAMI UADE,C04]NTY
FILE COPY
IRETTE 14T. ARCH
AR 0016279
?828 N 38 TH AVE
LLYWOOD FL�330
90A o.: 21�-0209.02
Expiration Date: 06/13/24
A-proval Date: 06/13/19
•
,'�9 13 Page 1 of 96
r
ROOFING SYSTEM APPROVAL
Catea-ory Roofing
Sub-Cateeorv: Single Ply Roofing
Material: TPO SA
Deck Tyne: Concrete
Maximum Design Pressure See specific assemblies
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product Dimensions Specifications Product Description
UltraPly TPO SA Various TAS 131 Reinforced TPO 0.045" or 0.060"
thick membrane.
UltraPly TPO Reinforced
Various
TAS 131
TPO curb flashing
Curb Corner
UltraPly 18" Curb
Various
TAS 131
TPO curb flashing
Flashing
UltraPly TPO
Various
TAS 131
Molded TPO for corner flashing
Inside/Outside Corner
UltraPly TPO Large Pipe
Various
TAS 131
TPO flashing for large round
Flashing
penetrations
UltraPly TPO T-Joint
Various
TAS 131
TPO flashing for T joints
Cover
UltraPly TPO Penetration
Various
TAS 131
A penetration sealing kit for
Kit
UltraPly TPO
UltraPly TPO Walkway
Various
TAS 131
TPO walkway pad
Pad
" UltraPly TPO Coated
Various
TAS 131
TPO laminated to hot -dipped
Metal
galvanized steel for flashing
UltraPly TPO Premium
Various
TAS 131
TPO walkway pad
Walkway Pad
UltraPly TPO Reinforced
Various
TAS 131
TPO flashing for round
Split Pipe Boot
penetrations 1" to 9" in diameter
UltraPly TPO 8"
Various
TAS 131
8" wide 60 mil TPO cover strip
Reinforced Cover Strip
UltraPly TPO Universal
Various
TAS 131
TPO flashing for round
. Pipe Boot
penetrations 1" to 6" in diameter
UltraPly TPO
Various
TAS 131
Unreinforced TPO used for
Unsupported Flashing
flashing
SBS Base
3.3" x 50'
ASTM 6163
Fiberglass reinforced SBS base
sheet
SBS Poly Torch Base
39.4" x 33'6"
ASTM D 6222
Polyester reinforced modified
bitumen membrane. Torch applied.
NOA No.: 15-0209.02
MIAMMAOE COUNTY. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 2 of 96
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product Dimensions Specifications Product Description
SBS. Glass Torch Base 39.4" x 33'10" ASTM D 6163 Modified bitumen base sheet with a
SBS Premium Base
SBS Poly Base
MB Base
BASEGARD SA
APP 80 Glass Base
V-Force
I.S.O. Stick
I.S.O. Twin Pack
Insulation Adhesive
I.S.O. Fix H
I.S.O. Spray R
SA Primer
APPROVED
39.4" x 50'
ASTM D 6164
39.4" x 50'
ASTM D 6164
36 x 108'
ASTM D 4601
39.4" x 65' 3"
ASTM D6163
39.4" x 65'4"
ASTM D6509
45" x 134"
ASTM D 5147,
1876,1970 and
ASTM E 96, 2178
5 gal &
Proprietary
1500 ml
1500 ml
Proprietary
301bs.
Proprietary
15 gal pail &
Proprietary
55 gal drum
5 gal.
Proprietary
burn -off film and reinforced with
non -woven fiberglass mat.
Polyester reinforced SBS modified
bitumen ply with sanded surfaces
Polyester reinforced SBS modified
bitumen membrane with sanded
surfaces.
Fiberglass reinforced base sheet,
asphalt coated on both sides.
Applied in hot asphalt or
mechanically attached.
Fiberglass reinforced SBS
modified bitumen, self -adhering
base sheet with a smooth sanded
surface.
Fiberglass reinforced modified
bitumen, smooth surfaced base
sheet.
A vapor retarder made of SBS
modified bitumen adhesive
laminated to a woven high density
polyethylene top surface
A dual component polyurethane
adhesive.
A dual component polyurethane
adhesive.
A single component polyurethane
adhesive.
A two-part polyurethane adhesive
Polymer based primer
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 3 of 96
APPROVED INSULATIONS:
Product Name
ISO 95+ GL
ISO 95+ GL Tapered
ISOGARD HD
ISOGARD HD Composite
DensDeck Prime
RESISTA
RESISTA Tapered
SECUROCK Gypsum -Fiber Roof
Board
GenFlex ISO Insulation
GenFlex ISO Insulation Tapered
Coated Glass Facer
Coated Glass Facer Tapered
GenFlex HD ISO
GenFlex HD Composite ISO
APPROVED FASTENERS:
Fastener Product
Number Name
1. Firestone Heavy -Duty
2. Concrete Drive Fastener
TABLE 2
Product Description
Manufacturer
(With Current NOA)
Polyisocyanurate foam insulation
Firestone Bldg. Products
Polyisocyanurate with a coated
Firestone Bldg. Products
fiberglass facer
Polyisocyanurate with a coated
Firestone Bldg. Products
fiberglass facer composite insulation.
Silicon treated gypsum
Georgia Pacific Gypsum LLC
Polyisocyanurate foam core laminated
Firestone Bldg. Products
to a coated fiberglass facer
Rigid, gypsum -based board stock
United States Gypsum Corp.
Polyisocyanurate foam insulation Firestone Bldg. Products
Polyisocyanurate foam insulation Firestone Bldg. Products
Polyisocyanurate with a coated Firestone Bldg. Products
fiberglass facer
Polyisocyanurate with a coated Firestone Bldg. Products
fiberglass facer composite insulation.
TABLE 3
Product
Description
#15 Fastener for steel,
Wood, concrete decks
Structural concrete
fastener
Manufacturer
Dimensions (With Current NOA)
N/A Firestone Bldg.
Products
Various Firestone Bldg.
Products
3. Insulation Fastening Plate Galvalume insulation plate 3" diameter
MIAM14DA0E COUNiY
Firestone Bldg.
Products
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 4 of 96
EVIDENCE SUBMITTED:
Test Aaency
Underwriters Laboratories Inc.
Factory Mutual Research
Corporation
TrinitylERD
PRI Construction Materials
Technologies, LLC
MIAMf DADE COUNTY
Test Identifier
03NK34486
3004249
3014031
3029384
3030650
3033218
3036642
3039133
3036747
3040535
3035017
3038191
3035560
3047700
3047398
3042666
3041939
3044047
3042665
797-07096-267
797-05604-267
797-05830-267
797-07680-267
797-08513-267
F8300.07.08
F8300.11.08-R3
FBP-038-02-01
FBP-038-02-02
FBP-044-02-01, R10
FBP-053-02-01
FBP-054-02-04, Rev 1
FBP-064-02-01
FBP-076-02-01
FBP-085-02-01, RI
FBP-115-02-01
FBP-149-02-01
FBP-154-02-02
FBP-158-02-01
FBP-162-02-01
FBP-165-02-01
FBP-166-02-01
FBP-175-02-01
FBP-176-02-01
FBP-178-02-03
FBP-185-02-02
FBP-206-02-01
Description
UL 790
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
4470
TAS 131/ ASTM D6878
TAS 131/ ASTM D6878
ASTM D6164
ASTM D6164
TAS 11411, J
TAS 110/ASTM D6131
FM 4474 B/TAS 114 D
ASTM D 6509
TAS 110
FM 4474 D/TAS 114 J
ASTM D 1644 & 2196
FM 4474 D
FM 4474 D
FM 4474 D
ASTM D 1970
FM 4474/TAS 114 J
ASTM D6163
FM 4474 D/TAS 114 J
ASTM D 4601
FM 4474 B/TAS 114 D
FM 4474 B/TAS 114 D
FM 4474 D/TAS 114 J
Date
03/22/05
11/03/99
07/22/02
06/07/10
07/10/09
08/12/08
10/09/09
04/07/11
02/12/10
10/05/10
08/22/12
08/04/11
01/11/10
08/16/13
08/15/13
08/14/12
08/14/12
05/17/12
05/04/12
08/22/12
06/07/10
08/30/10
09/12/12
06/18/13
07/30/08
02/25/11
12/27/10
12/28/10
06/01/17
10/08/12
02/07/13
08/02/12
10/23/12
10/04/12
04/04/13
12/18/13
12/18/13
04/28/14
10/02/13
04/28/14
05/15/14
04/28/14
07/15/14
07/23/14
07/31/14
02/02/15
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 5 of 96
Test Agency Test Identifier
Description
Date
FBP-208-02-01
TAS 131/ASTM D6878
04/06/15
FBP-214-02-01.1
ASTM C 1289
11/09/16
FBP-214-02-02
ASTM C 1289
02/10/15
FBP-222-02-03
TAS 114 C
04/01/15
FBP-225-02-01
FM 4474 D/TAS 114 J
03/19/15
FBP-233-02-03
FM 4474 D/TAS 114 J
06/01/15
FBP-246-02-01
ASTM C 1289
10/05/15
FBP-260-02-02
FM 4474 B
10/09/15
FBP-280-02-01
ASTM C 1289
04/27/16
FBP-293-02-01
ASTM D 4601
04/27/16
FBP-315-02-01
ASTM C 1289
10/28/16
NOA No.: 15-0209.02
.MIAMI DARE COUtdTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 6 of 96
APPROVED ASSEMBLIES
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(1): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick N/A N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to % " wide ribbons spaced 12" o.c. or with I.S.O. Stick applied in % to 1" wide
ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Middle Insulation Layer (Optional) Insulation Fasteners " Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A N/A
Note: Optional middle insulation shall be adhered to the previous insulation layer with I.S.O.
Twin Pack Insulation Adhesive applied in Y2 to % " wide ribbons spaced 12" o.c. or I.S.O. Stick
applied in IWI to 1" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
• One or more layers
Additional Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) 1 Density/ftz
ISO 95+ GL Tapered, ISO 95+ GL, RESISTA, GenFlex ISO Insulation Tapered, GenFlex ISO
Insulation, Coated Glass Facer
Minimum: 1" thick NA NA
Note: Optional additional middle insulation shall be adhered to the previous insulation layer with
I.S.O. Twin Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" oxPlease refer
to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer
Plywood
Minimum 19/32" thick
MIAMfDARE APPROVED]
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A - N/A
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 7 of 96
Note: Top Insulation layer shall be adhered to the previous insulation layer with I.S.O. Twin Pack
Insulation Adhesive applied in % to %"wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
MIAMI�ADB COUNTY
-45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 8 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(2): Vapor Barrier and insulation adhered with approved adhesive; membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier V-Force self -adhered to the primed concrete deck.
Note: Concrete deck shall be primed with primer -Force WB Primer at a rate of 150-200 ff/gal
and allowed to dry prior to application of Vapor Barrier.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick N/A N/A
Note: Insulation shall be adhered to the Vapor Barrier using I.S.O. Spray R, I.S.O. Stick or I.S.O.
Twin Pack Adhesive, applied in %" to 1" wide ribbons spaced 12" on center. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -57.5 psf. using I.S.O. Stick in ribbons 3/a" —1" wide spaced 12" o.c. (See
Pressure: General Limitation #9)
-97.5 psf using I.S.O. Twin Pack Adhesive in ribbons 3/a" —1" wide spaced 12"
o.c. (See General Limitation #9)
NOA No.: 15-0209.02
MIAM(-0ADE COUNTY. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 9 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(3): Base layer of insulation mechanically fastened; top layer adhered with approved
adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier One ply of BASEGARD SA is self -adhered to a concrete deck primed with SA
Primer applied at a rate of 200 ft2/gal.
One or more layers
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1-1/2" thick N/A N/A
Note: Base Insulation layer shall be adhered to the deck with I.S.O. Twin Pack Insulation
Adhesive applied in %"to 3/a" wide ribbons spaced 12" o.c. or I.S.O. Stick applied in 3/a" to 1" wide
ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
ISOGARD HD, GenFlex HD ISO
Minimum %'1 thick N/A
• ISOGARD 13D Composite, GenFlex HD Composite ISO
Minimum 2" thick
N/A
Fastener
Density/ft'
N/A
N/A
Note: Top insulation layer shall be adhered to base insulations with I.S.O. Twin Pack Insulation
Adhesive in continuous %11 to %11 wide beads spaced 12" o.c. or I.S.O. Stick applied in continuous
%11 to 1" wide ribbons spaced 12" o.c. See Roofing Application Standard RAS 117 for fastening
details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
wide side laps.
Maximum Design
Pressure: -90 psf. (See General Limitation #7)
NOA No.: 15-0209.02
M AMiDAvE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 10 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: 2500 psi or greater structural concrete or concrete plank
System Type A(4): One or more layers of insulation adhered with approved adhesive; membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick N/A N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to % " wide ribbons, spaced as listed below, Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck Prime
Minimum %" thick
N/A
N/A
Note: All subsequent layers of insulation shall be adhered to the previous layer of insulation with
I.S.O. Twin Pack Insulation Adhesive applied in % to %11 wide ribbons Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -127.5 psf. using I.S.O Twin Pack Insulation Adhesive in ribbons spaced 12" o.c.
(See General Limitation #9)
-187.5 psf. using I.S.O Twin Pack Insulation Adhesive in ribbons spaced 8" o.c.
(See General Limitation #9)
-247.5 psf. using I.S.O Twin Pack Insulation Adhesive in ribbons spaced 4" o.c.
(See General Limitation #9)
NOA No.: 15-0209.02
MU MICADE COUNTY Expiration Date: 06/13/24
` Approval Date: 06/13/19
Page 11 of 96
Membrane Type:
Single Ply, TPO, Reinforced
Deck Type 3I:
Concrete, Insulated
- Deck Description:
Min. 2500 psi structural concrete or concrete plank.
System Type A(5): Vapor Barrier and insulation adhered with approved adhesive; membrane
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier: One ply of APP 80 Glass Base torch adhered to the concrete deck.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fF
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1 Y211 thick N/A N/A
Note: Base insulation shall be adhered to the vapor barrier I.S.O. Twin Pack Insulation Adhesive
applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1 %11 thick
N/A
N/A
Note: Optional Middle insulation shall be adhered to the base insulation layer with I.S.O. Twin
Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer (Optional) Insulation Fasteners Fastener
_ (Table 3) Density/ff
ISO 95+ GL Tapered, RESISTA Tapered, GenFlex ISO Insulation Tapered, Coated Glass Facer
Tapered
Minimum: %11 thick with a Y41' per ft. taper N/A N/A
Note: Optional Top insulation shall be adhered to the previous insulation layer with I.S.O. Twin
Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -142.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAM1 DADE COUF{TY. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 12 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(6): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick
N/A
N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1" thick
N/A
N/A
Note: Optional Middle insulation shall be adhered to the base insulation layer with I.S.O. Twin
Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft
ISO 95+ GL Tapered, RESISTA Tapered, GenFlex ISO Insulation Tapered, Coated Glass Facer
• Tapered
Minimum: %11 thick with a W' per ft. taper N/A
N/A
Note: Optional Top insulation shall be adhered to the previous insulation layer with I.S.O. Twin
Pack Insulation Adhesive applied in % to % " wide ribbons spaced as listed below Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -142.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Mwra14Dc►aE caurvnr Expiration Date: 06/13/24
. . P
Approval Date: 06/13/19
Page 13 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(7): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick
N/A
N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Stick applied in %11 to 1" wide
ribbons spaced 12" o.c., Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Middle Insulation Layer (Optional)
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Optional Middle insulation shall be adhered to the base insulation layer with I.S.O. Stick
Pack Insulation Adhesive applied in %" to 1" wide ribbons spaced 12" o.cPlease refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, ISO 95+ GL Tapered, RESISTA, RESISTA Tapered, GenFlex ISO Insulation,
GenFlex ISO Insulation Tapered, Coated Glass Facer, Coated Glass Facer Tapered
Minimum: 1" thick with a %11 per ft. taper N/A N/A
Note: Optional Top insulation shall be adhered to the previous insulation layer with I.S.O. Stick
applied in %" to 1" wide ribbons spaced 12" o.cPlease refer to Roofing Application Standard RAS
117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -142.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIWIDAOE COUN Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 14 of 96
Membrane Type: Single Ply, Thermoplastic, TPO
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(8): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick N/A N/A
Note: Base Insulation layer shall be adhered to the deck with I.S.O. Twin Pack Insulation
Adhesive applied in V2" to %11 wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/W
ISO 95+ GL, GenFlex ISO Insulation,
Minimum 1.5" thick
N/A
N/A
Note: Optional Middle Insulation layer shall be adhered to the Base Insulation Layer with I.S.O.
Twin Pack Insulation Adhesive applied in %'1 to %11 wide ribbons spaced 12" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
" (Table 3) Density/fe
ISOGARD HD, GenFlex HD ISO
Minimum'/z" thick N/A N/A
Note: Top Insulation layer shall be adhered to the previous layer of roof insulation with I.S.O.
Twin Pack Insulation Adhesive applied in %11 to 3/4" wide ribbons spaced 12" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -157.5 psf (See General Limitation #9)
NOA No.: 15-0209.02
MIAM14DADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 15 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(9): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick N/A N/A
Note: All Insulation layers shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in 1/2 to 3/4 in. wide ribbons spaced 12" o.c.. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
WAMIDADE COUNTY
-157.5 psf (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 16 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Mn. 2500 psi structural concrete or concrete plank.
System Type A(10): One or more layers of insulation adhered with approved adhesive; membrane
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Insulation Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Spray R, I.S.O. Fix H or I.S.O.
Stick applied in %" to 1" wide ribbons, spaced 12" o.c. or I.S.O. Twin Pack Insulation Adhesive
applied in continuous %" to %11 wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -145 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MUU41-MOECOUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 17 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type A(11): One or more layers of insulation adhered with approved adhesive; membrane
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A N/A
Note: Optional Base layer of insulation shall be adhered to the deck with I.S.O. Spray R, I.S.O.
Fix II or I.S.O. Stick applied in % to 1" wide ribbons, spaced 12" o.c. or I.S.O. Twin Pack
Insulation Adhesive applied in % to 3/a" wide ribbons, spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer
DensDeck Prime
Minimum 1/4" thick
Insulation Fasteners Fastener
(Table 3) Density/ff
N/A N/A
Note: Top layer of insulation shall be adhered with I.S.O. Stick applied in % to 1" wide ribbons
spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
MAMt-DAUE'GOUNTY
.p
-160 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 18 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: 2500 psi or greater structural concrete or concrete plank
System Type A(12): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners . Fastener
(Table 3) Density/ftz
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
N/A
N/A
Note: Insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive applied
in % to %11 wide ribbons spaced as listed below Please refer to Roofing Application Standard RAS
117 for insulation attachment
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -165 psf. using I.S.O. Twin Pack Insulation Adhesive with ribbons spaced 12"
Pressure: o.c. (See General Limitation #9)
-210 psf. using I.S.O. Twin Pack Insulation Adhesive with ribbons spaced 8"
o.c. (See General Limitation #9)
MU M OADE COUNTY
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 19 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(13): Vapor Barrier and insulation adhered with approved adhesive; membrane
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier: One ply of MB Base, SBS Base, SBS Poly Base or SBS Premium Base fully
adhered to the concrete deck with a full mopping of hot asphalt applied at a rate
of 20 — 25 lbs./square.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A N/A
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/W
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum %" thick with a'/a" per ft. taper N/A N/A
Top Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ff
ISOGARD 1®, GenFlex HD ISO
Minimum %11 thick N/A N/A
Plywood
Minimum 19/32" thick N/A N/A
DensDeck Prime
Minimum %" thick N/A N/A
• Note: Insulation shall be adhered using I.S.O. Twin Pack Insulation Adhesive in continuous %1' to
%1' wide beads spaced 12" o.c., I.S.O. Fix II or I.S.O. Stick applied in continuous %11 to 1" wide
ribbons spaced 12" o.c. See Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -172.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MlAt WMDECOUNTY. Expiration Date: 06/13/24
...vrf ,:
Approval Date: 06/13/19
Page 20 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(14): Vapor Barrier and insulation adhered with approved adhesive; membrane
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier One ply of MB Base, SBS Base, SBS Poly Base or SBS Premium Base fully
adhered to the concrete deck with a full mopping of hot asphalt applied at a rate
of 20 — 25 lbs./square.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick N/A N/A
Note: Base Insulation shall be adhered using I.S.O. Twin Pack Insulation Adhesive in continuous
V211 to %'1 wide beads spaced 12" o.c. See Roofing Application Standard RAS 117 for insulation
attachment.
Middle Insulation Layer (Optional)
Insulation Fasteners
Fastener
(Table 3)
Density/fe
Tapered ISO 95+ GL, ISO 95+ GL, RESISTA Tapered, RESISTA, GenFlex ISO Insulation,
Tapered GenFlex ISO Insulation, Coated Glass
Facer; Coated Glass Facer Tapered
Minimum: 1" thick
N/A
N/A
• Top Insulation Layer
Insulation Fasteners
Fastener
•
(Table 3)
Density/ft2
DensDeck Prime
Minimum:'/" thick
N/A
N/A
• Plywood
Minimum 19/32" thick
N/A
N/A
Note: Insulation shall be adhered using I.S.O. Twin Pack Insulation Adhesive in continuous %11 to
%11 wide beads spaced 12" o.c., See Roofing Application Standard RAS 117 for insulation
attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -45 psf (See General Limitation #9) for Plywood
Pressure: -60 psf. (See General Limitation #9) for DensDeck Prime
NOA No.: 15-0209.02
Mwrrcnaoe country Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 21 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(15): Vapor Barrier and insulation adhered with approved adhesive; membrane
• adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier One ply of MB Base, SBS Base, SBS Poly Base or SBS Premium base fully
adhered to the concrete deck with a full mopping of hot asphalt applied at a rate
of 20 — 25 lbs./square.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISOGARD HD, GenFlex HD ISO
Minimum: %11 thick N/A N/A
DensDeck Prime
Minimum: %11 thick N/A N/A
Note: Insulation shall be adhered using I.S.O. Twin Pack Insulation Adhesive in continuous %" to
W wide beads spaced 12" o.c., I.S.O. Fix H or I.S.O. Stick applied in continuous W to 1" wide
ribbons spaced 12" o.c. See Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
MIAMf DADE COUNTY:
...M ,
-172.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 22 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: 2500 psi or greater structural concrete or concrete plank
System Type A(16): One or more layers of insulation adhered with approved asphalt; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
Top Insulation Layer (Optional)
Insulation Fasteners
(Table 3)
N/A
Insulation Fasteners
(Table 3)
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum'/:" thick start with a'/a" per ft. taper N/A
Fastener
Density/fe
N/A
Fastener
Density/fe
N/A
Note: Base insulation shall be adhered to the deck in full mopping of approved asphalt within the
EVT range and at a rate of 20 to 401bs/100 fe. All subsequent layers of insulation shall be adhered
to the previous layer of insulation in full mopping of approved asphalt within the EVT range and
at a rate of 20 to 40 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Composite insulation panels used as a top layer shall be placed with the polyisocyanurate side
facing down.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -180 psf. without cover board (See General Limitation #9)
NOA No.: 15-0209.02
Muar�� anE cour�rc Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 23 of 96
Membrane Type:
Deck Type 3I:
• Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type A(17): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick N/A N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Stick applied in %1' to 1 " wide
ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Note: Optional middle insulation shall be adhered to the previous insulation layer with I.S.O.
Stick applied in 3/4 to 1 " wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Additional Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL Tapered, ISO 95+ GL, RESISTA Tapered, RESISTA, GenFlex ISO Insulation,
Tapered GenFlex ISO Insulation, Coated Glass Facer, Coated Glass Facer Tapered
Minimum: 1" thick NA NA
Note: Optional additional middle insulation shall be adhered to the previous insulation layer with
I.S.O. Stick applied in 3/4 to 111 wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Top Insulation Layer
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
MIAMI DADE.COUNTY
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 24 of 96
Note: Top Insulation layer shall be adhered to the previous insulation layer with I.S.O. Stick
applied in 3/4 to 1 " wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
• wide side laps.
Maximum Design
Pressure:
'MIAM14DA9E COUNTY.
e s
-187.5 psf (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 25 of 96
Membrane Type:
Deck Type 3I:
• Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type A(18): Vapor Barrier and insulation adhered with approved adhesive; membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier: V-Force self -adhered to the primed concrete deck with 3" wide side lap.
Note: Concrete deck shall be primed with V-Force WB Primer at a rate of 0.25 gal/100 ft' and
allowed to dry prior to application of Vapor Barrier.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1/2" thick N/A N/A
Note: Base insulation layer shall be adhered to the Vapor Barrier using I.S.O. Spray R ribbon
adhesive, applied in %" to 1" wide ribbons spaced 12" on center. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck Prime
Minimum'/4" thick
N/A
N/A
_ Note: Top insulation layer shall be adhered to the Base insulation layer using I.S.O. Spray R
ribbon adhesive, applied in %11 to 1" wide ribbons spaced 12" on center. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -187.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
•MIAMbDADECOUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 26 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
System Type A(19):
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick
N/A
N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Stick applied in %11 to 1 " wide
ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick N/A N/A
Note: Optional Middle insulation shall be adhered to the base insulation layer with I.S.O. Stick
applied in 3/4 to 1 " wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Additional Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, ISO 95+ GL Tapered, RESISTA, RESISTA Tapered, GenFlex ISO Insulation,
Tapered, GenFlex ISO Insulation, Coated Glass Facer, Coated Glass Facer Tapered
Minimum: 1" thick with a %11 per ft. taper N/A
N/A
Note: Additional Optional Middle insulation shall be adhered to the base insulation layer with
I.S.O. Stick applied in 3/4 to 1 " wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
MIAHIOAOEC UNTY
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 27 of 96
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft,
DensDeck Prime
Minimum: 1/4" thick N/A N/A
Note: Top insulation shall be adhered to the previous insulation layer with I.S.O. Stick applied in
3/4 to 111 wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAMI DAVE cauwrr Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 28 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: 2500 psi or greater structural concrete or concrete plank
System Type A(20): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Use Two (2) base insulation layers
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fts
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
N/A
N/A
Note: Base Insulation layer shall be adhered to the deck with I.S.O. Twin Pack Insulation
Adhesive applied in %" to %11 wide ribbons spaced 8" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Top Insulation Layer
DensDeck Prime
Minimum'/4" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: All subsequent layers of insulation shall be adhered to the previous layer of insulation using
I.S.O. Twin Pack Insulation Adhesive applied in %11 to %11 wide ribbons spaced 8" o.c. Please refer
to Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as the base
layer shall only be used as the base layer with a second layer of approved top layer insulation
installed as the final membrane substrate. Composite insulation boards used as a top layer shall
be installed with the polyisocyanurate face down.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -195 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAM1 DADE COUNTY: Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 29 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(21): Insulation adhered with approved adhesive; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/W
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick N/A N/A
Note: Base insulation shall be adhered using ISO Spray R ribbon, applied in %" to 1" wide
ribbons spaced 12" on center. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Top Insulation Layer
DensDeck Prime
Minimum 1/4" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Top insulation shall be adhered using ISO Spray R ribbon, applied in %11 to 1" wide ribbons
spaced 12" on center. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -205 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MwrsavabE tort Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 30 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 31: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(22): Insulation adhered with approved adhesive; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Insulation Fasteners Fastener
(Table 3) Density/fF
Minimum: 1.5" thick N/A N/A
Note: Base insulation shall be adhered using ISO Spray R ribbon, applied in %11 to 1" wide
ribbons spaced 12" on center. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -210 psf. (See General Limitation #9)
NOA No.: 15-0209.02
M"M QADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 31 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(23): One or more layers of insulation adhered with -approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick
N/A
N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1" thick N/A N/A
Note: Optional Middle insulation shall be adhered to the base insulation layer with I.S.O. Twin
Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
One or two layers of the following:
• Additional Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL Tapered, ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Tapered GenFlex ISO
Insulation, Coated Glass Facer
• Minimum: %11 thick with a %" per ft. taper N/A
N/A
Note: Additional Optional Middle insulation shall be adhered to the base insulation layer with
I.S.O. Twin Pack Insulation Adhesive applied in % to % "wide ribbons spaced 12" o.c. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Additional Second Middle Insulation Layer Insulation Fasteners Fastener
(Optional) (Table 3) Density/W
ISO 95+ GL, ISO 95+ GL Tapered, RESISTA, RESISTA Tapered, GenFlex ISO Insulation,
Tapered GenFlex ISO Insulation, Coated Glass Facer, Coated Glass Facer Tapered
Minimum: %11 thick with a %11 per ft. taper N/A N/A
NOA No.: 15-0209.02
htuartuoaoE couNnr. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 32 of 96
Note: Optional Second Middle insulation shall be adhered to the previous insulation layer with
I.S.O. Twin Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation layer Insulation Fasteners Fastener
(Table 3) Density/fe
DensDeck Prime
Minimum %11 thick N/A N/A
Note: Top insulation of insulation shall be adhered to the previous layer of insulation using I.S.O.
Twin Pack Insulation Adhesive applied in V2" to %11 wide ribbons spaced 8" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -240 psf. (See General Limitation #9)
Mwt�ioE cautvTM NOA No.: 15-0209.02
.. � � Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 33 of 96
i
A
Membrane Type:
Deck Type 3I:
Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type A(24): Vapor Barrier and insulation adhered with approved adhesive; membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Barrier: SBS Poly Torch Base or SBS Glass Torch Base membrane is torch adhered to
the primed concrete deck.
Note: Concrete deck shall be primed with ASTM D 41 asphalt primer at a rate of 0.75 -1 gal/100
ft2 and allowed to dry prior to application of Vapor Barrier.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
N/A
N/A
NOTE: Base insulation shall be adhered to the Vapor Barrier using ISO Twin Pack Insulation
Adhesive, applied in %" to %11 wide ribbons spaced 12" on center. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck Prime
Minimum: %11 thick N/A N/A
Note: All subsequent layers of insulation shall be adhered to the previous layer of insulation using
I.S.O. Twin Pack Insulation Adhesive applied in %11 to %11 wide ribbons spaced 12" o.c. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -232.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
M"14 AUB COUN Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 34 of 96
Membrane Type:
Deck Type 3I:
Single Ply, TPO, Reinforced
Concrete, Insulated
Deck Description: 2500 psi or greater structural concrete or concrete plank
System Type A(25): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and. System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick N/A N/A
Top Insulation Layer
DensDeck Prime
Minimum %" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Base insulation shall be adhered to the deck, and top insulation shall be adhered to the base
insulation, in full mopping of approved asphalt within the EVT range and at a rate of 20 to 25
lbs/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -247.5 psf. with coverboard (See General Limitation #9)
NOA No.: 15-0209.02
Mwt�tt�aflE COUNn Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 35 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(26): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick
Middle Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick
Top Insulation Layer
DensDeck Prime
Minimum: %?' thick
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/ft'
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: (Optional) Concrete deck shall be optionally primed with ASTM D 41 asphalt primer at a
rate of % to 1 gal/sq. and allowed to dry prior to application of insulation. Insulation shall be
adhered to the deck in full mopping of approved asphalt within the EVT range and at a rate of 20
to 25 lbs/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -247.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MM14)ADE CO, Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 36 of 96
f,
Membrane Type:
Deck Type 3I:
Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type A(27)• One or more layers of insulation adhered with approved adhesive; membrane
f illy adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A
N/A
Note: Base Insulation layer shall be adhered to the deck with I.S.O. Twin Pack Insulation
Adhesive applied in %11 to %11 wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Middle Insulation Layer (Optional)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
Top Insulation Layer
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Optional Middle Insulation layer shall be adhered to the Base Insulation layer with I.S.O.
Twin Pack Insulation Adhesive applied in %11 to %" wide ribbons spaced 12" o.c. Top Insulation
layer shall be adhered to the previous layer with Twin Pack Insulation Adhesive applied in %" to
%11 wide ribbons spaced 12" o.c Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
wide side laps.
Maximum Design
Pressure: -247.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAM14)4D, COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 37 of 96
Membrane Type: Single Ply, Thermoplastic, TPO
Deck Type 31: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(28): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick N/A N/A
Note: Base Insulation Layer shall be adhered with I.S.O. Fix H, I.S.O. Stick applied in continuous
%" to 1" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
(Optional) Middle Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Optional Middle Insulation Layer shall be adhered with I.S.O. Fix H or I.S.O. Stick applied
in continuous 3/4 to 1 in. wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Top Insulation Layer
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/ftz
N/A N/A
Note: Top Insulation layer shall be adhered with I.S.O. Fix H or I.S.O. Stick applied in continuous
3/4 to 1 in. wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation Adhesive
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -300 psf (See General Limitation #9)
NOA No.: 15-0209.02
Mwni nape cauNric Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 38 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(29): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulation.
Insulation Insulation Fasteners Fastener
(Table 3) Density/ft2
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick N/A N/A
Note: All insulation layers shall be adhered with I.S.O. Fix H applied in continuous %1' to 1" wide
ribbons spaced 4" o.c. or I.S.O. Stick applied in continuous %11 to 1" wide ribbons spaced 12" o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
wide side laps.
Maximum Design
Pressure: -300 psf. (See General Limitation #9)
NOA No.: 9
MIAMMADECO�Expiration
iration Date:: 06/106/13/24/24
Approval Date: 06/13/19
Page 39 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(30): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
RESISTA, Coated Glass Facer
Minimum 1.5" thick N/A N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to % in. wide ribbons spaced 6" o.c. or with I.S.O. Stick or I.S.O. Fix H applied in %11
to 1" wide ribbons, spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Middle Insulation Layer (Optional)
RESISTA, Coated Glass Facer
Minimum 1.5" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Optional middle insulation layer shall be adhered to the previous layer of insulation using
the same method of adhesion as the base layer. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Top Insulation Layer (Optional)
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Optional top layer of insulation shall be adhered with I.S.O. Stick or I.S.O. Fix H applied in
continuous %" to 1" wide ribbons spaced 6" o.c. Please refer to Roofing Application Standard
• RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
wide side laps.
Maximum Design -360 psf. (See General Limitation #9) TPO SA adhered to RESISTA
Pressure: -300 psf. (See General Limitation #9) TPO SA adhered to ISOGARD HD
NOA No.: 15-0209.02
MIAMt�DALIE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 40 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(31): One or more layers of insulation adhered with approved adhesive; membrane
Fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum: 1" thick
N/A
N/A
Note: Base insulation shall be adhered to the deck with I.S.O. Twin Pack Insulation Adhesive
applied in % to %"wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick
N/A
N/A
Note: Optional middle insulation shall be adhered to the previous insulation layer with I.S.O.
Twin Pack Insulation Adhesive applied in to % " wide ribbons spaced 12" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Additional Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL Tapered, ISO 95+ GL, RESISTA, GenFlex ISO Insulation Tapered, GenFlex ISO
Insulation, Coated Glass Facer
Minimum 1" thick
NA
NA
Note: Optional second additional middle insulation shall be adhered.to the previous insulation
layer with I.S.O. Twin Pack Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Additional Second Middle Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL Tapered, ISO 95+ GL, RESISTA, Tapered RESISTA, GenFlex ISO Insulation,
Tapered GenFlex ISO Insulation, Coated Glass Facer, Coated Glass Facer Tapered
Minimum 1" thick N/A N/A
NOA No.: 15-0209.02
MIAMfDADECOUNT'f Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 41 of 96
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/W
ISOGARD HD, GenFlex HD ISO
Minimum V2" thick N/A N/A
Note: Top Insulation layer shall be adhered to the previous insulation layer with I.S.O. Twin Pack
Insulation Adhesive applied in % to % " wide ribbons spaced 12" o.c. or with I.S.O. Spray R,
I.S.O. Fix II or I.S.O. Stick applied in % to 1" wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -82.5 psf (See General Limitation #9)
NOA No.: 15-0209.02
WAMICADE COUN1Tf Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 42 of 96
Membrane Type: Single Ply, Thermoplastic, TPO
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(32): One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Insulation Insulation Fasteners Fastener
(Table 3) Density/ft2
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick N/A N/A
Note: All insulation layers shall be adhered with I.S.O. Stick, applied in continuous 3/" to 1" wide
ribbons spaced 4" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 3"
wide side laps.
Maximum Design
Pressure: -300 psf (See General Limitation #9)
NOA No.: 15-0209.02
MIAMIIDE GouNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 43 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
System Type A(33):
Single Ply, Thermoplastic, TPO
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
One or more layers of insulation adhered with approved adhesive; membrane
fully adhered.
All General and System Limitations apply.
Base Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum: 1.5" thick
Top Insulation Layer
DensDeck Prime
Minimum: %'1 thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Insulation Fasteners Fastener
(Table 3) Density/ftz
N/A N/A
Note: Optional — Concrete deck shall be primed with ASTM D 41 asphalt primer at a rate of % to
1 gal/sq. and allowed to dry prior to application of insulation. Insulation shall be adhered to the
deck in full mopping of approved asphalt within the EVT range and at a rate of 20-25 lbs/sq.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -247.5 psf; (See General Limitation #9)
NOA No.: 15-0209.02
MUM -DADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 44 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type A(34): Insulation adhered with approved adhesive; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISOGARD HD, GenFlex HD ISO
Minimum: 1/2" thick N/A N/A
Note: Base insulation shall be adhered using I.S.O. Fix H, I.S.O. Stick, I.S.O. Twin Pack
Insulation Adhesive or ISO Spray R ribbon, applied in %" to 1" wide ribbons spaced 12" on
center. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: 445 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAMIDAVE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 45 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(1): Base layer of insulation mechanically fastened, optional top layer fully adhered
with approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick 1 or 2 with 3
Top Insulation Layer (Optional) Insulation Fasteners
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick N/A
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum %11 thick with a'/a" per ft. taper N/A
Fastener
Density/ft'
1:2 ft'
Fastener
Density/fe
N/A
N/A
Note: Base layer shall be mechanically attached with fasteners and density described. All other
layers of insulation shall be adhered to base insulations with I.S.O. Twin Pack Insulation Adhesive
applied in %11 to 3/a" wide ribbons spaced 12 in. o.c. Insulation panels, listed are minimum sizes and
dimensions; if larger panels are used the number of fasteners per board shall be increased
maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #7)
NOA No.: 15-0209.02
-MLWI DARE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 46 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(2): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum V thick N/A N/A
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum %11 thick with a'/a" per ft. taper N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2 %11 thick 1 or 2 with 3 1:4 ft'
Note: Optional Base layer shall be loose laid. Middle layer shall be simultaneously fastened with
fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if
larger panels are used, the number of fasteners shall be increased maintaining the same fastener
density. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1.5" thick
N/A
N/A
Note: Optional top layer shall be adhered to top insulation with I.S.O. Twin Pack Insulation
Adhesive in continuous V211 to %11 wide beads spaced 12" o.c. or, I.S.O. Fix II or I.S.O. Stick applied
in continuous %1' to 1" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: 45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAMI-VADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 47 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(3): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener Density/ft'
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1%" thick 1 or 2 with 3 1:2 fe
Note: Optional Base layer shall be loose laid. Middle layer shall be simultaneously fastened with
fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if
larger panels are used, the number of fasteners shall be increased maintaining the same fastener
density. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener Density/ftZ
(Table 3)
ISOGARD HD, GenFlex HD ISO
Minimum %" thick N/A N/A
Note: Top layer shall be adhered to top insulation with I.S.O. Twin Pack Insulation Adhesive in
continuous %:" to %11 wide beads spaced 12" o.c. or, I.S.O. Fix H or I.S.O. Stick applied in
continuous %" to 1" wide ribbons spaced 12" o.c. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Mwrrr anE eouNrY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 48 of 96
Membrane Type: Single Ply,TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(4): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick 1 or 2 with 3 1:2 ft'
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are, used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Middle Insulation Layer Insulation Fasteners
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A
Additional Middle Insulation Layer (Optional) Insulation Fasteners
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum %'1 thick with a %11 per ft. taper N/A
Fastener
Density/ft'
N/A
Fastener
Density/fe
N/A
ky;l
Note: Middle insulation layers shall be adhered to base insulations with I.S.O. Twin Pack
Insulation Adhesive in continuous %" to %" wide beads spaced 12" o.c. I.S.O. Fix H or I.S.O. Stick
applied in continuous 3/4" to 1" wide ribbons spaced 12" o.c. See Roofing Application Standard
RAS 117 for insulation attachment.
Top Insulation Layer
Insulation Fasteners
(Table 3)
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum %1' thick N/A
°MIAMIDADE COUNTY
Fastener
Density/ft'
N/A
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 49 of 96
Note: Top layer of insulation shall be adhered to previous layer with I.S.O. Twin Pack Insulation
Adhesive in continuous %" to %" wide beads spaced 12" o.c. or I.S.O. Fix II or I.S.O. Stick applied
in continuous %" to 1" wide ribbons spaced 12" o.c. See Roofing Application Standard RAS 117
for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
• wide side laps.
Maximum Design
Pressure:
MIAMI-ADE COUNTY
-45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 50 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(5): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick ' 1 or 2 with 3 1:2 ft'
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Middle Insulation Layer Insulation Fasteners
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A
Additional Middle Insulation Layer (Optional) Insulation Fasteners
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A
Tapered ISO 95+ GL, Tapered GenFlex ISO Insulation
Minimum %'1 thick with a'/4" per ft. taper N/A
Fastener
Density/ft'
N/A
Fastener
Density/fe
N/A
N/A
Note: Middle insulation layers shall be adhered to base insulations with I.S.O. Twin Pack
Insulation Adhesive in continuous %" to %" wide beads spaced 12" o.c. or I.S.O. Fix H or I.S.O.
Stick applied in continuous %" to 1" wide ribbons spaced 12" o.c. See Roofing Application
Standard RAS 117 for insulation attachment.
Top Insulation Layer
Insulation Fasteners Fastener
(Table 3) Density/ft,
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board, ISOGARD HD, GenFlex HD ISO
Minimum'/:" thick N/A N/A
NOA No.: 15-0209.02
CMAMIG �►fle eCouNrY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 51 of 96
Note: Top layer of insulation shall be adhered to previous layer with I.S.O. Twin Pack Insulation
Adhesive in continuous %Z" to %" wide beads spaced 12" o.c. or I.S.O. Fix II or I.S.O. Stick applied
in continuous 3/a" to 1" wide ribbons spaced 12" o.c. See Roofing Application Standard RAS 117
for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Mu4MiGAvE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 52 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(6)• Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick 1 or 2 with 3 1:1.6 fe
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board, ISOGARD HD, GenFlex HD ISO
Minimum %11 thick N/A N/A
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1%'1 thick N/A
N/A
Note: Top layer of insulation shall be adhered to base insulations with I.S.O. Twin Pack Insulation
Adhesive in continuous %11 to %11 wide beads spaced 6" o.c. or I.S.O. Fix H or I.S.O. Stick (not for
ISOGARD HD (GenFlex HD ISO) or ISOGARD HD Composite (GenFlex HD Composite ISO))
applied in continuous %" to 1" wide ribbons spaced 6 o.c. Insulation panels listed are minimum
sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for
fastening details.
Membrane: Mn. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Muu`st nwoEtout�nr Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 53 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(7): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, , GenFlex ISO Insulation,
Minimum 1.5" thick
1 or 2 with 3
1:1.78 ft2
Note: Base layer shall be fastened with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1.5" thick N/A N/A
Note: Top layer shall be adhered to base insulation layer with I.S.O. Stick, I.S.O. Fix H or I.S.O.
Spray R applied in continuous %'1 to 1" wide ribbons spaced 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7)
NOA No.: 15-0209.02
KMANDAUE'GOUN Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 54 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(8): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1.78 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Middle Insulation Layer
Insulation Fasteners
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A
Fastener
Density/ft2
N/A
Note: Middle Insulation shall be adhered with I.S.O. Twin Pack Insulation Adhesive in continuous
V211 to 3/a" wide ribbons spaced 6" o.c. or I.S.O. Spray R applied in continuous %11 to 1" wide
ribbons spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Layer
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/ftz
N/A N/A
Note: Top layer of insulation shall be adhered to base insulations with I.S.O. Twin Pack
Insulation Adhesive in continuous %" to %" wide ribbons spaced 6" o.c. or I.S.O. Spray R, I.S.O.
Fix H or I.S.O. Stick applied in continuous %11 to 1" wide ribbons spaced 6" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7):
NOA No.: 15-0209.02
MAMr-DADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 55 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(9): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1.78 fe
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Top Insulation Layer
ISOGARD HD, GenFlex HD ISO
Minimum %11 thick
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Top insulation layer shall be adhered to base insulations with I.S.O. Twin Pack Insulation
Adhesive in continuous %11 to %11 wide ribbons spaced 6" o.c. or I.S.O. Spray R, I.S.O. Fix H or
I.S.O. Stick applied in continuous 3/a" to 1" wide ribbons spaced 6" o.c. See Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -67.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
CMLMA AUE COUNTY Expiration Date:-06/13/24
020902
Approval Date: 06/13/19
Page 56 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank
System Type B(10): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 2" thick
1 or 2 with 3
1:1.78 ft2
Note: Base layer shall be fastened with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick N/A
N/A
Note: Top layer shall be adhered to top insulation with I.S.O. Stick applied in continuous %" to 1"
wide ribbons spaced 6" o.c. or I.S.O. Spray R applied in continuous %" to 1" wide ribbons spaced
6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -67.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Muarsi�aoe 1UNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 57 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(11): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GeuFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1.6 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation
panels listed are minimum sizes and dimensions; if larger panels are ,used the number of fasteners
per board shall be increased maintaining the same fastener density. See Roofing Application
Standard RAS 117 for fastening details.
Top Insulation Layer
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
N/A N/A
Note: Top layer of insulation shall be adhered to base insulations with I.S.O. Twin Pack Insulation
Adhesive in continuous'/:" to %11 wide beads spaced 6" o.c., I.S.O. Fix II or I.S.O. Stick applied in
continuous 3/a" to 1" wide ribbons spaced 6" o.c. See Roofing Application Standard RAS 117 for
insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
- 75 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MLAW If 4 =E.cOUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 58 of 96
Membrane Type:
Deck Type 7I:
Deck Description:
Single Ply, TPO, Reinforced
Recover, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type B(12): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/W
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A N/A
ISO 95+ GL Tapered, GenFlex ISO Insulation Tapered
Minimum %11 thick with a %11 per ft. taper N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1.6 ft2
Note: Middle layer shall be mechanically attached with fasteners and density described.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/W
ISOGARD HD, GenFlex HD ISO
Minimum 1/2" thick N/A N/A
Note: Top layer of insulation shall be adhered to middle insulation layer with I.S.O. Twin Pack
Insulation Adhesive in continuous %"to %" wide ribbons spaced 6" o.c. or I.S.O. Fix H or I.S.O.
Stick applied in continuous W1 to 1" wide ribbons spaced 6" o.c. See Roofing Application Standard
RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMfUADECOUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 59 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(13): Base layer of insulation mechanically fastened, top layer adhered with approved
adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more. layers of any of the following insulations:
Base Insulation Layer
RESISTA, Coated Glass Facer
Minimum 1.5" thick
Top Insulation Layer
RESISTA, Coated Glass Facer
Minimum 1.5" thick
Insulation Fasteners Fastener
(Table 3) Density/ft2
1 or 2 with 3 1:1 ft2
Insulation Fasteners Fastener
(Table 3) Density/fe
N/A N/A
Note: Base layer shall be mechanically attached with fasteners and density described. Top layer of
insulation shall be adhered to base insulations with I.S.O. Twin Pack Insulation Adhesive in
continuous %" to %" wide beads spaced 12" o.c. or I.S.O. Stick, I.S.O. Fix II applied in continuous
%11 to 1" wide ribbons spaced 12" o.c. Insulation panels listed are minimum sizes and dimensions;
if larger panels are used the number of fasteners per board shall be increased maintaining the
same fastener density. See Roofing Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -120 psf. (See General Limitation #7)
Mwr�► arseUN courser NOA No.: 15-0209.02
� Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 60 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(14): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1 ftz
Note: Base layer shall be fastened with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick
N/A
N/A
Note: Top layer shall be adhered to top insulation with I.S.O. Twin Pack Insulation Adhesive in
continuous'/:" to 3/a" wide beads spaced 4" o.c. or, I.S.O. Fix II or I.S.O. Stick applied in
continuous %'1 to 1" wide ribbons spaced 4" o.c. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -127.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAM14DADE GOUNiY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 61 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(15): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) 1 Density/ff
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1 ftz
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
DensDeck Prime, ISOGARD HD, GenFlex HD ISO
Minimum %" thick N/A N/A
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1%11 thick N/A N/A
Note: Base layer shall be mechanically attached with fasteners and density described. Top layer of
insulation shall be adhered to base insulations with I.S.O. Twin Pack Insulation Adhesive in
continuous %" to V wide beads spaced 4" o.c., I.S.O. Fix H or I.S.O. Stick (not for ISOGARD HD
(GenFlex HD ISO) (or ISOGARD HD Composite (GenFlex ]RD Composite ISO)) applied in
continuous %11 to 1" wide ribbons spaced 4" o.c. Insulation panels listed are minimum sizes and
dimensions; if larger panels are used the number of fasteners per board shall be increased
maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -127.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIJA R )ADE GOUN. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 62 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(16): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 - 1:1 ft,
Note: Base layer shall be loose laid. Middle layer shall be simultaneously fastened with fasteners
and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels
are used, the number of fasteners shall be increased maintaining the same fastener density. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener Density/ftz
(Table 3)
ISOGARD BD, GenFlex 13D ISO
Minimum 1/2" thick N/A N/A
Note: Top layer shall be adhered to top insulation with I.S.O. Twin Pack Insulation Adhesive in
continuous %" to %" wide ribbons spaced 4" o.c. or, I.S.O. Fix H or I.S.O. Stick applied in
continuous %11 to 1" wide ribbons spaced 4" o.c. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
Maximum Design
Pressure:
MIAM14DADE COUNTY.
wide side laps.
-135 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 63 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type B(17): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:1 ft2
Note: Base layer shall be loose laid. Middle layer shall be simultaneously fastened with fasteners
and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels
are used, the number of fasteners shall be increased maintaining the same fastener density. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
ISOGARD HD, GenFlex HD ISO
Minimum %'1 thick N/A N/A
Note: Top layer shall be adhered to top insulation with I.S.O. Twin Pack Insulation Adhesive in
continuous %'1 to %11 wide ribbons spaced 4" o.c. or, I.S.O. Fix H or I.S.O. Stick applied in
continuous 3/a" to 1" wide ribbons spaced 4" o.c. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Membrane: Min. 45 mil. U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2" wide
side laps.
Maximum Design
Pressure: -135 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAM14DADE COIUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 64 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(1): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1" thick N/A
N/A
ISO 95+ GL Tapered, GenFlex ISO Insulation Tapered
Minimum %11 thick with a 1/a" per ft. taper N/A
N/A
Middle Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1-1/2" thick N/A
N/A
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft2
' ISOGARD HD, GenFlex HD ISO
Minimum %11 thick 1 or 2 with 3
1:2.1 ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
' Minimum 1" thick 1 or 2 with 3
1:2.1 ft2
. DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/4" thick 1 or 2 with 3
1:2.1 ft2
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/211 thick 1 or 2 with 3
1:2.1 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger'panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
NOA No.: 15-0209.02
Mt1W14=E C0U TY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 65 of 96
Membrane:
Maximum Design
Pressure:
Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
-45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAMICADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 66 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Mn. 2500 psi structural concrete or concrete plank.
System Type C(2): All layers of insulation simultaneously attached membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlez ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
SECUROCK Gypsum -Fiber Roof Board
Minimum V411 thick 1 or 2 with 3 1:1.78 fe
RESISTA, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1:1.78 ft'
ISO 95+ GL, ISOGARD HD Composite, GenFlez ISO Insulation, GenFlez HD Composite ISO
Minimum 1.5" thick 1 or 2 with 3 1:1.78 ff
DensDeck Prime
Minimum V211 thick
1 or 2 with 3 1:1.78 ft2
Note: All layers shall be simultaneously fastened. See top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions. If larger panels are used, the number
_ of fasteners shall be increased using the same fastener density. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
MIAMIDADE C-0
-45 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 67 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
System Type C(3): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3 1:2.67 ft'
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3 1:2.67 ft2
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1:2.67 ftz
Note: All layers shall be simultaneously fastened. See top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions. If larger panels are used, the number
of fasteners shall be increased using the same fastener density. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
MIAM DADE COUN
-45 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 68 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(4): Membrane bonded over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick N/A N/A
Middle Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1/2" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1:5.3 ftz
ISOGARD HD, GenFlex HD ISO
Minimum %" thick
1 or 2 with 3 1:5.3 ff
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick 1 or 2 with 3
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3
Plywood
Minimum 19/32" thick
1:5.3 fe
1:5.3 ft'
1 or 2 with 3 1:5.3 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
NOA No.: 15-0209.02
M AMI.Oc►ue COUN Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 69 of 96
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAMICADE COUNT'! Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 70 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(5): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ff
ISOGARD HD, GenFlex HD ISO
Minimum %" thick 1 or 2 with 3 1:2.7ft2
ISO 95 + GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1:2.7 ft2
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum %11 thick 1 or 2 with 3 1:2.7 fe
ISOGARD HD Composite, GenFlex HD ISO Composite
Minimum 1.5" thick 1 or 2 with 3 1:2.7 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil. U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MIAM14MUE COUNTY- Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 71 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(6): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISOGARD HD, GenFlex HD ISO
Minimum 1" thick 1 or 2 with 3 1: 1.78 ft2
ISO 95 + GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1: 1.78 ft'
DensDeck Prime, SECUROCK Gypsum -Fiber Boards
Minimum 1/4" thick 1 or 2 with 3 1: 1.78 fe
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1:1.78 fe
• Note: All layers shall be simultaneously fastened; see top layer for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
• Maximum Design
Pressure: -45 psf. (See General Limitation #7)
NOA No.: 15-0209.02
M�rrtuanecoucrry Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 72 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(7): Base layer of insulation mechanically fastened, optional top layer adhered with
approved adhesive
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL, GenFlex ISO Insulation
Minimum 1-1/2" thick N/A N/A
Middle Insulation Layer (Optional) Insulation Fasteners Fastener Density/ft2
(Table 3)
ISO 95+ GL Tapered, GenFlex ISO Insulation Tapered
Minimum 1/2" thick N/A N/A
Note: Base layer shall be loose laid. Middle layer shall be preliminary fastened. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall
be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for fastening details.
Top Insulation Layer Insulation Fasteners Fastener Density/ft2
(Table 3)
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum 1/4" thick 1 or 2 with 3 1:2 ff
ISOGARD HD Composite, ISO 95+ GL, GenFlex IID Composite ISO, GenFlex ISO Insulation
Minimum 1-1/2" thick 1 or 2 with 3 1:2 W
RESISTA, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1:2 ff
Plywood
Minimum 19/32" thick 1 or 2 with 3 1:2 fe
Note: All layers shall be simultaneously fastened; see top layer for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
NOA No.: 15-0209.02
Mwrri�ue►aE couNrr Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 73 of 96
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
MWM��AUE COUNiY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 74 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(8): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved,
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft'
ISO 95+ GL, RESISTA, GenFlez ISO Insulation, Coated Glass Facer
Minimum 1%" thick 1 or 2 with 3
1:2.7 fe
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3
1:2.7 ft2
ISOGARD HD Composite, GenFlez HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3
1:2.7 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
M[WIDADE.COUNT"E Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 75 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type C(9): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ff
ISO 95+ GL, RESISTA, GenFlez ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
RESISTA, Coated Glass Facer
Minimum 1" thick 1 or 2 with 3 1:1.6 fe
ISO 95 + GL, ISOGARD HD Composite, GenFlez ISO Insulation, GenFlez HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3. 1:1.6 fe
SECUROCK Gypsum Fiber Roof Board, DensDeck Prime
Minimum %" thick 1 or 2 with 3
1:1.6 fe
Note: All layers shall be simultaneously fastened. See top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions. If larger panels are used, the number
of fasteners shall be increased using the same fastener density. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
• Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -52.5 psf. (See General Limitation #7)
Pressure:
MM4ECOMUMSrNOA No.: 15-0209.02
M
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 76 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(10): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %"thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick 1 or 2 with 3
RESISTA, Coated Glass Facer
Minimum 2" thick
1 or 2 with 3
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1.5" thick 1 or 2 with 3
Fastener
Density/ft2
1:.1.78 ft2
1:.1.78 ft2
1:.1.78 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -52.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMI-DAD' COUNTYExpiration Date: 06/13/24
Approval Date: 06/13/19
Page 77 of 96
Membrane Type: Single Ply, Thermoplastic, TPO
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type C(11): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %"thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, ISOGARD HD Composite, RESISTA, GenFlex ISO Insulation, Coated Glass Facer,
GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1: 1.78 ftz
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick 1 or 2 with 3 1: 1.78 ft2
Note: All layers shall be simultaneously fastened. See top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions. If larger panels are used, the number
of fasteners shall be increased using the same fastener density. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7)
NOA No.: 15-0209.02
"UMD Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 78 of 96
i
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(12): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %"thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3 1: 2.13 ft'
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1: 2.13 W
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with l .5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7)
COUNTY Expiration Date: 06/13/24
' NOA No.: 15-0209.02
AMIAM14=6... W
Approval Date: 06/13/19
Page 79 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(13): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %" thick N/A N/A
Top Insulation Layer
Insulation Fasteners
(Table 3)
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1" thick 1 or 2 with 3'
Fastener
Density/ft'
1: 1.33 fe
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with '1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Miarf! oa►nE counn Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 80 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
System Type C(14):
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
Membrane bonded over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer
Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick
N/A
N/A
Top Insulation Layer
Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISOGARD HD, GenFlex HD ISO
Minimum'/:" thick
1 or 2 with 3
1:4 ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick
1 or 2 with 3
1:4 W
SECUROCK Gypsum Fiber Roof Board
Minimum 1/2" thick
1 or 2 with 3
1:4 ftz
DensDeck Prime
Minimum %11 thick
1 or 2 with 3
1:4 fe
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-112" thick
1 or 2 with 3
1:4 ft2
Plywood
Minimum 19/32" thick
1 or 2 with 3 1:4 fe
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -60 psf. (See General Limitation #7)
Mu�rn�ave counanr NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 81 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(15): Membrane fully adhered over mechanically fastened insulation
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3 1: 4.0 ft2
ISOGARD )® Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1: 4.0 ff
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure:
CAIMAM14DADE
-62.5 psf. (See General Limitation #9)
NOA No.: 15-0209.02
Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 82 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(16): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1/2" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
SECUROCK Gypsum -Fiber Roof Board
Minimum V2" thick 1 or 2 with 3 1:1.6 fe
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1:1.6 fe
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: —67.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMMAaE ClOUN1Y Expiration Date: 06/13/24
� . p.
Approval Date: 06/13/19
Page 83 of 96
Membrane Type:
Deck Type 3I:
Deck Description:
System Type C(17):
Single Ply, TPO, Reinforced
Concrete, Insulated
Min. 2500 psi structural concrete or concrete plank.
Membrane bonded over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
(Table 3)
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1.5" thick N/A
Top Insulation Layer
Plywood
Minimum 19/32" thick
ISOGARD HD, GenFlex BD ISO
Minimum %" thick
Insulation Fasteners
(Table 3)
1 or 2 with 4
1 or 2 with 4
Fastener
Density/W
N/A
Fastener
Density/ft2
1:2.7 ft2
1:2.7 ft2
DensDeck Prime, SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick 1 or 2 with 4 1:2.7 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with. 1.5" wide heat weld at the 6"
wide side laps.
Maximum Design
Pressure:
-75 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Mti°; can Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 84 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(18): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
RESISTA, ISOGARD HD Composite, Coated Glass Facer, GenFlex,HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1:1.6 ft2
ISO 95 + GL, GenFlex ISO Insulation
Minimum 2" thick
1 or 2 with 3 1:1.6 ft'
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3 1:1.6 ft2
Note: All layers shall be simultaneously fastened. See top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions. If larger panels are used, the number
of fasteners shall be increased using the same fastener density. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -75 psf. (See General Limitation #7)
NOA No.: 15-0209.02
tMWNtt OV1E7E GOt7Nl Y Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 85 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type.C(19): All layers of insulation simultaneously attached; membrane bonded.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 1/21' thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
SECUROCK Gypsum Fiber Roof Board
Minimum %11 thick 1 or 2 with 3 1:1.78 fe
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1:1.78 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
Muartiane touNrt Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 86 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(20): Membrane adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A
N/A
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3
1:1.6 ft2
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum %11 thick 1 or 2 with 3
1:1.6 ftz
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3
1:1.6 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -82.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MUAMIDAOE COUNTY= Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 87 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(22): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A
N/A
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft2
RESISTA, ISO 95+ GL, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3
1:1 fe
SECUROCK Gypsum -Fiber Roof Board, DensDeck Prime
Minimum %11 thick 1 or 2 with 3
1:1 ft2
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3
1:1 ft,
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressures: -150 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMI DADE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 89 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(23): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved. and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ftz
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1.5" thick 1 or 2 with 3 1: 1.33 ft'
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -112.5 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMGOADE COUNTY. Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 90 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(24): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ff
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 2" thick 1 or 2 with 3 1: 1.33 fe
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -120 psf. (See General Limitation #7)
NOA No.: 15-0209.02
MIAMtDADE COUNTY Expiration Date: 06/13/24
9 Approval Date: 06/13/19
Page 91 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(25): Membrane adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners
Fastener
(Table 3)
Density/fe
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum %" thick N/A
N/A
Top Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ISO 95+ GL, RESISTA, GenFlex ISO Insulation, Coated Glass Facer
Minimum 2" thick 1 or 2 with 3
1:1 ft2
DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/2" thick 1 or 2 with 3
1:1 ft,
ISOGARD HD Composite, GenFlex HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3
1:1 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -142.5 psf. with ISO 95+ GL, RESISTA, DensDeck Prime, or ISOAGRD HD
Composite (See General Limitation #7)
-112.5 psf. with SECUROCK Gypsum Fiber Roof Board (See General
Limitation #7)
NOA No.: 15-0209.02
MIAMIJDIAaE COUNTY Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 92 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Concrete, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(26): All layers of insulation simultaneously attached; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table L
(Optional) Vapor Retarder Polyethylene Sheet 4-6 mil thick Min. 2" wide laps sealed
with duct tape
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, ISO 95 + GL Tapered, RESISTA, RESISTA Tapered, GenFlez ISO Insulation,
Tapered GenFlez ISO Insulation, Coated Glass Facer, Coated Glass Facer Tapered
Minimum 1-1/2" thick N/A N/A
T9p insulation Layer Insulation :Fasteners Fastener
(Table 3) Ilensity/ft2
SECUROCK Gypsum -Fiber Roof Board
I Minimum 1/21' thick 1 or 2 with 3 1:4 ft2
ISOGARD HD Composite, GenFlez HD Composite ISO
Minimum 1-1/2" thick 1 or 2 with 3 1: 4 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil UltraPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 15-0209.02
"MWAMI-�DADE UN Expiration Date:-06/13/24
0209.02
Approval Date: 06/13/19
Page 93 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I Steel, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank.
System Type C(27): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/fe
ISO 95+ GL, RESISTA, DensDeck Prime, GenFlez ISO Insulation, Coated Glass Facer
Minimum V2" thick N/A N/A
Top Insulation Layer
Insulation Fasteners
(Table 3)
ISOGARD HD Composite, GenFlez HD Composite ISO
Minimum 1 %11 thick 1 or 2 with 3
Fastener
Density/fe
1:2.13 ft2
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -67.5 psf. (See General Limitation #7)
Pressure:
NOA No.: 15-0209.02
MIAMIDWDEGOWNTT Expiration Date: 06/13/24
all Approval Date: 06/13/19
Page 94 of 96
Membrane Type: Single Ply, TPO, Reinforced
Deck Type 3I: Steel, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type C(28): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer (Optional) Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, RESISTA, DensDeck Prime, GenFlez ISO Insulation, Coated Glass Facer
Minimum %11 thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
ISOGARD HD Composite, GenFlez HD Composite ISO
Minimum 1 %11 thick 1 or 2 with 3 1:1.78 fe
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number
of fasteners per board shall be increased maintaining the same fastener density. See Roofing
Application Standard RAS 117 for fastening details.
Membrane: Min. 45 mil U1traPly TPO SA self -adhered with 1.5" wide heat weld at the 2"
wide side laps.
Maximum Design -75 psf. (See General Limitation #7)
Pressure:
NOA No.: 15-0209.02
MIAMI DIADE COUNTY: Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 95 of 96
y
CONCRETE DECK SYSTEM LmTATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed,
a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener
patterns and density. All testing and fastening design shall be in compliance with Testing Application
Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137, calculations shall be
signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using
the fastening pattern of the top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down,the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. Insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a
specific system. Should the fastener resistance be less than that required, as determined by the Building
Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener
spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS
105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared,
signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant (When this limitation is specifically referred within this NOA, General
Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 15-0209.02
CMWQiMDE Cavnrr Expiration Date: 06/13/24
Approval Date: 06/13/19
Page 96 of 96