Loading...
HomeMy WebLinkAboutNOA; Series 1300 Steel Panel (2inches & ^inches Clips)MIAMa E MIAW-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADAIMSTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.pov/economy Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the ART may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Series 1300 Steel. Panel (2" Clips and. 6" Clips) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 13-0416.08 and consists of pages 1 through S. C H A R E TT E INT. ARCH AR 0016279 The submitted documentation was reviewed by Freddy Semino 2828 N �+ HOLLYWO OCO PY T APPROVED NOA No.:18-0711.11 Expiration Date: 08/09/2023 Approval Date: 08/09/2018 ' � Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Metal, Panels (Non -Structural) Materials: Steel Deck Type: Wood -Maximum Design Pressure —165 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description Series 1300 Length: various TAS 125 Corrosion resistant, galvalume, preformed, Width: 16" standing seam. Coated, pre -finished, metal Thickness 0.024 (24ga) panels. Min. Yield Strength: 57 ksi. 2" Clip Length: 2" TAS 125 Corrosion resistant, galvalume, preformed, Width: 1" coated, pre -finished, metal clips for use in Height:1-9/16" Field or Perimeter and Corner Area of Roof. Thickness 0.020 - 6" Clip Length: 6 V4' TAS 125 Corrosion resistant, galvalume, preformed, Width: 1" coated, pre -finished, metal clips for use in • Height: 1.65" perimeter and Comer Areas of Roof. Thickness 0.0276 Trim Pieces Length: varies N/A Corrosion resistant, galvalume, preformed, Width: varies coated, pre -finished, trim pieces. Thickness 0.0276. EVIDENCE SUBNIITTED: Test Agencv Test Identifier Test NameMmort Date Morton International AS-0286-91L Salt Spray Feb. 1986 ASTM B 117 Morton International AS-0286-91T Accelerated Weathering Feb. 1986 ASTM G 23 Architectural Testing Inc. 01-32797.01 TAS 100 Nov. 1998 Architectural Testing Inc. 01-32797.03 ASTM E 8 Nov. 1998 Hurricane Test Laboratory, LLC. 0155-0615-05 TAS 125 Feb. 2006 Architectural Testing 92270.01-109-18 TAS 125 October. 2009 NOA No.:18-0711.11 rtuaHtt Dane counrrir Expiration Date: 08/09/2023 PPROVED- Approval Date: 08/09/2018 Page 2 of 5 APPROVED ASSEMBLIES: System A-1: Series 1300 Panel, Panel 16" Wide Deck Type: Wood, Non -Insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32') the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 VV annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Englert's current published installation instructions. • . Metal Panels and Install the "Series 1300 Panel' and accessories in compliance with the current published Accessories: installation instructions and details in Englert's Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. Panels shall be installed with approved Panel Clips located at each panel rib side lap spaced at a maximum, listed in Table A below, parallel to roof slope, fastened with #10 wafer head spoiler tip corrosion resistant screws of sufficient length to penetrate through the sheathing a minimum 3/16 of an inch. Use 2 screws for the 2" clip and use 4 screws for the 6" clip. Standing seams shall be mechanically seamed to a 900 degree seam, (single lock).. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Cornerl Perimeter and Corner112 Maximum Design Pressures —69.25 psf —106.75 psf —165 psf Maximum Clip Spacing 24" o.c. 12" O.C. 12" O.C. Clip Size 2" Clip 2" Clip 6" Clip 1. Extrapolation shall not be allowed 2. Place a bead of Bostik 70-05A sealant in the lateral seams prior to seaming, NOA No.: 18-0711.11 Expiration Date: 08/09/2023 Approval Date: 08/09/2018 Page 3 of 5 SYSTEM LIlVIITATIONS 1. 2. 3. 4. 5. 6. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. MIAMI•DADE COUNTY All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20 of the Florida Administrative Code. Panels may be jobsite roll formed with machine model # 10811107 from Englert, Inc. NOA No.: 18-0711.11 CMLAWD�ADECOM- Expiration Date: 08/09/2023 Approval Date: 08/09/2018 Page 4 of 5 PROFILE DRAWINGS 2" CLIP DETAIL (FIELD AND PERIMETER AND CORNER OPTION) APPROVED MIN. EW AT CLIP ISOMETRIC (PERIMETER AND CORNER OPTION Bostik Sealant Before Seaming 90 degree 90 degree Seam Seam w/Bostik Sealant SERIES 1300 PANEL SYSTEM END OF THIS ACCEPTANCE NOA No.:18-0711.11 Expiration Date: 08/09/2023 Approval Date: 08/09/2018 Page 5 of 5