HomeMy WebLinkAboutNOA; Series 1300 Steel Panel (2inches & ^inches Clips)MIAMa E MIAW-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADAIMSTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.pov/economy
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the ART may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Series 1300 Steel. Panel (2" Clips and. 6" Clips)
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 13-0416.08 and consists of pages 1 through S. C H A R E TT E INT. ARCH
AR 0016279
The submitted documentation was reviewed by Freddy Semino 2828 N �+
HOLLYWO OCO PY
T
APPROVED
NOA No.:18-0711.11
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
' � Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Metal, Panels (Non -Structural)
Materials:
Steel
Deck Type:
Wood
-Maximum Design Pressure
—165 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions Specifications
Description
Series 1300 Length: various
TAS 125
Corrosion resistant, galvalume, preformed,
Width: 16"
standing seam. Coated, pre -finished, metal
Thickness 0.024 (24ga)
panels.
Min. Yield Strength: 57 ksi.
2" Clip Length: 2"
TAS 125
Corrosion resistant, galvalume, preformed,
Width: 1"
coated, pre -finished, metal clips for use in
Height:1-9/16"
Field or Perimeter and Corner Area of Roof.
Thickness 0.020
- 6" Clip Length: 6 V4'
TAS 125
Corrosion resistant, galvalume, preformed,
Width: 1"
coated, pre -finished, metal clips for use in
• Height: 1.65"
perimeter and Comer Areas of Roof.
Thickness 0.0276
Trim Pieces Length: varies
N/A
Corrosion resistant, galvalume, preformed,
Width: varies
coated, pre -finished, trim pieces.
Thickness 0.0276.
EVIDENCE SUBNIITTED:
Test Agencv Test Identifier
Test NameMmort Date
Morton International AS-0286-91L
Salt Spray Feb. 1986
ASTM B 117
Morton International AS-0286-91T
Accelerated Weathering Feb. 1986
ASTM G 23
Architectural Testing Inc. 01-32797.01
TAS 100 Nov. 1998
Architectural Testing Inc. 01-32797.03
ASTM E 8 Nov. 1998
Hurricane Test Laboratory, LLC. 0155-0615-05
TAS 125 Feb. 2006
Architectural Testing 92270.01-109-18
TAS 125 October. 2009
NOA No.:18-0711.11
rtuaHtt Dane counrrir Expiration Date: 08/09/2023
PPROVED-
Approval Date: 08/09/2018
Page 2 of 5
APPROVED ASSEMBLIES:
System A-1: Series 1300 Panel, Panel 16" Wide
Deck Type: Wood, Non -Insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift See Table A below
Pressure:
Deck Attachment: In accordance with applicable building code, but in no case shall it be less than # 8d annular
ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick
(Minimum 15/32') the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type H installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps
and 12 gauge 1 VV annular ring -shank nails, spaced 6" o.c. at all laps and two staggered
rows 12" o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with Englert's current published installation instructions.
• . Metal Panels and Install the "Series 1300 Panel' and accessories in compliance with the current published
Accessories: installation instructions and details in Englert's Installation Manual. Flashings,
penetrations, valley construction and other details shall be constructed in compliance with
Roofing Application Standard RAS 133.
Panels shall be installed with approved Panel Clips located at each panel rib side lap spaced
at a maximum, listed in Table A below, parallel to roof slope, fastened with #10 wafer head
spoiler tip corrosion resistant screws of sufficient length to penetrate through the sheathing
a minimum 3/16 of an inch. Use 2 screws for the 2" clip and use 4 screws for the 6" clip.
Standing seams shall be mechanically seamed to a 900 degree seam, (single lock)..
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Cornerl
Perimeter and Corner112
Maximum Design Pressures
—69.25 psf
—106.75 psf
—165 psf
Maximum Clip Spacing
24" o.c.
12" O.C.
12" O.C.
Clip Size
2" Clip
2" Clip
6" Clip
1. Extrapolation shall not be allowed
2. Place a bead of Bostik 70-05A sealant in the lateral seams prior to seaming,
NOA No.: 18-0711.11
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 3 of 5
SYSTEM LIlVIITATIONS
1.
2.
3.
4.
5.
6.
Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and comers).
Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
MIAMI•DADE COUNTY
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20 of the Florida Administrative Code.
Panels may be jobsite roll formed with machine model # 10811107 from Englert, Inc.
NOA No.: 18-0711.11
CMLAWD�ADECOM- Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 4 of 5
PROFILE DRAWINGS
2" CLIP DETAIL
(FIELD AND PERIMETER AND CORNER OPTION)
APPROVED
MIN.
EW AT
CLIP ISOMETRIC
(PERIMETER AND CORNER OPTION
Bostik Sealant
Before Seaming 90 degree 90 degree
Seam Seam w/Bostik
Sealant
SERIES 1300 PANEL SYSTEM
END OF THIS ACCEPTANCE
NOA No.:18-0711.11
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 5 of 5