Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NOA; Series Sentinel 130 Aluminium Fixed Window
66 L MIAMI-DARE MIAMI DADS COUNW, FLORMA PRODUCT CONTROL SECTION , 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599. NOTICE OF ACCEPTANCE (NOA) www.miamiaade.Zov/builaina CGI Windows and Doors, Inc. 3780 W 104 Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. - DESCRIPTION: Series "Sentinel 130" Aluminum Fixed Window — L.M.L APPROVAL DOCUMENT: Drawing No. PW130LMI-NOA, titled "Sentinel 130 Alum Fixed Window . (L.M.I.)(S.M.I.)", sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted. herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the. performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Bu�Q�ci�l ,� This NOA revises NOA No.17-0918.07 and consists of this page 1 and evidence p g,3 y E-4, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. J a �� NOA No.19-0603.02 rFoboe cGut z ' at September 22,.2020 Approval Date: July 03, 2019 Page 1 CHARETTE INT. ARCH AR 0016279 2828 N 38 TH AVE HOLLYWOOD .FL 33021 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No.10-0510.13) 2. Drawing No. W10-02, titled "Series Sentinel 130 Alum Fixed Window (L.M.I.) (S.M.I.)", sheets 1, 1.1, 2, 3, 4, 5 and 6 of 6, dated 01/30/10, with revision G, dated 08/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 17-091&X9 B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed " window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0413.03) 2. Test reports on: 1) Uniform Static Air, Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15--0413.03) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04116115, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15--0413.03) Awe?,0214 _J9. _. Manuel Product Control903 ri NOA No.1.02 Expiration Date: September 22, 2020 Approval Date: July 03, 2019 E-1 CGI Windows and Doors. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED . B. TESTS (cowpwED) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 -5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a Sentinel 130 aluminum fixed window, prepared by Hurricane Test Laboratory, Test Report No. HTL-0080-0130-10, dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition (2017), dated July 15, 2017, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 17-0918 07) 2. Glazing complies with ASTM E1300-09. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice. of Acceptance No. 17-0712.03 issued to.Eastman Chemical.Company.(MA) . for their "Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with. PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 5th Edition (2014), with FBC 6a' Edition (2017) and of no financial interest, dated August 15, 2017, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 17-0918 079 Manu a P.E. Product Con of miner NOA 9-0603.02. Expiration Date: September 22, 2020 Approval Date: July 03, 2019 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE:' EVIDENCE SUBMTTED F. STATEMENTS (Cor NEED) 2. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.13) 3. Test Proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.E., Supervisor, Product Control Section. (Submitted under NOA No.15-0413.03) G. OTHERS 1. Notice of Acceptance No. 15-0413.03, issued to C.GI Windows & Doors, for their Series "Sentinel 130" Aluminum Fixed Window — L.M.I. approved on 06/25/15 and expiring on 09/22/20. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. PW130LMI-NOA, titled "Sentinel 130 Alum Fixed Window (L.M.I.)(S.M.I.)", sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC; TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 56Q aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8916, dated 04/10/19, signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Water Resistance Test, per FBC, TAS 202-94 3) Small Missile Impact Test per FBC, TAS 201-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked up drawings and installation diagram of a series 130 and 410 aluminum fixed windows, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-19-8917, dated 04/09/19, signed and sealed by Idalmis Ortega, P.E. XA Manu , P.E. Product Co rol E miner NOA -0603.02 Expiration Date: September 22, 2020 Approval Date: July 03, 2019 E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and. White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice. of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVR Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 3. Notice of Acceptance No..18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflez CP - Saflez and Saflez HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No.17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflez Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6a' Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. 2. Statement letter of no financial interest; dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. 3. Proposal No.19-0219 issued by the Product Control Section, dated March 13, 2019, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. G. OTHERS 1. Notice of Acceptance No.17-0918.07, issued to CGI Windows and Doors, Inc. for their Series "Sentinel 130" Aluminum Fixed Window - L.M.I. approved on 11/22/17 and expiring on 09/22/20. Manuel er .E. Product Control xa er NOA No. 1 3.02 Expiration Date: September 22, 2020 Approval Date: July 03, 2019 E-4 . FLANGE WIDTH D.L. OPG. 18• MAX. 6' MAX. I 'HEAD/SILL A 3 SHORTER CORNERS SIDES rn IL II II II II II C II II II II d u n n u u u ^1 u n 9 P B 3 11 SERIES 130 SENTINEL ALUMINUM FIXED Wr"OW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF FIX./FIX. OR FIX. WDW. WITH OTHER MIAMI—DADE COUNTY APPROVED WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. TYPICAL ELEVATIONS ANCHOR SPACING SHOWN HEREIN APPUCABLE TO FLANGE AND FLUSH FRAMES. SEE SHEET 2 FOR FIN FRAMES. ca• WINDOW WINDOL W WIDTH WINDOW WIDTH SIDES 3 W. WIDTH 3 ; EQUAL LEG FRAME wINDo�THH WINDOW Ir`--,I L - — i i WINDOW 1 1 WINDOW W WIDTH _ , WINDOWH PRODUCT REVISED as complying wiY1160 Flmide Bldldmg Code I I a % r , r — — -T AuDau I •D I I § z I I I �a 3 By Dade L — — J W. WIDTH THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE SHUTTERS ARE NOT REQUIRED. REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING (- DAYI ITE OPENINGS: HIGH VELOCITY HURRICANE ZONE (HVHZ). I I ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE D.L.O. HEIGHT = BUCK HEIGHT — 3.00" 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS D.L.O. WIDTH = BUCK WIDTH — 3.00' DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. THE BUILDING STRUCTURE. 3 % 11111111i ANCHORS SHALL ON DETAILS AND SPECIFIEDEEMBEDMENT D AS NTo MI.. ``�?ON INSTALLED PER MANEUCORRINSTRUCTIOOSION NS. BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. $ I I SENTINEL 130 ALUM FIXED WINDOW (L.M.I.)(S.M.IJ ,. _ ,. ®Im act Resistant DOOR �`\CENSF ,�(��% A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. L .J Description: Doh: WEigDiRWIGFII— ALL SHIMS TO BE HIGH IMPACT, NON-METALUC AND NON -COMPRESSIBLE. : * , No. 58705 MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE THE ADOPTED ELAND LAM. GLASS TYPICAL ELEVATIONS 5=19 nsor..+o.nstr..+m.i.a,rtsuu ..I: am.asass+o l'v..: >'ouss.rsn PREPARED BY LYNN MILLER - = � •4W REQUIREMENTS OF STANDARDS. L IS GENERIC ES CODE V THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR Revision: Ree.By: Rev. ,Optp,^, 1070 TECHNOLOGY DRNE %�0 ••. EOF� ' SPECIFIC OF OF ISAROUNDCO,PENINC INSULATING LAM.GLASS ORIGINAL ISSUE r^ N. VENICE, FL34275 'g47 T •. ' STRUCTURE RECEMGETHISIPRODUCT�A D SEALNGFOR WATERACY SMALL MISSILE IMPACT ( I a6o lsoo tc ��57''•'.�,•�ORIDP„••G���: INFILTRATION RESISTANCE ETC. LARGE MISSILE IMPACT sen°l` seer°' Dro.trg M°' ', ` R°°' CO+�i56 2Doares 7 is/O i�II NAL7111`` CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, PW-130 LMI N.T.S. 1 of 7 PW130LMI•NOA 0 n WGmaRe Ms AND TO BE REVIEWED BY BUILDING OFFICIAL CERT. OF AUTH.82O286 A. LYNN MILLER, P.E. P.ES 56705 48' BUCK WIDTH D.L. OPG. m 16' MAX 1rA S1RAlGHT SIDES z �0 d 11 B D 11 11 II 11 i __.l— 11 II It 11 11 II II II II u u n u n u n u FP (SURF dR' 1. STRAIGHT 16' MA%. SIDES- TYPICAL ELEVATIONS FIN FRAMES PRODUCT' REVISBD s—plyiegwilh th Florida Building Code Acaplaete No ,Q2 ALTERNATE SHAPES AS SHOWN ON SHEET I ALSO AVAILABLE FOR FIN FRAMES By INir>® Ooetro TRIe: Dram W. SENTINEL 130 ALUM FIXED WINDOW (L.M.I.)(S.M.I.) AGK � Impact Resistant . .. LYNN ` ............ Windows 6 '' ocl:Nsec'•. 06Drs a�•. P ' ` N0. 58705 •� ' TYPICAL ELEVATIONS, CONT. 5/22119 sew �. wm mu4 xa.e•, n usu * sa: em.eea.us ese..•nxen ^ Revis7sn: Rev. W. Rev. Oda: PREPARED BY LYNN MILLl32 �p • U 7 DRNE S ORIGINAL ISSUE N.7VENIC[:, FOL 34275LOGY i�Q •'•, q'J '••�\ i T F� �!/: (�1) 4�60.16 ��,�SS.F<ORIDP,.NG�2` elny o. Rw: Series1Wde4- S d. set �oPW13NOLMI-NOA 12M a =19 PW-130 LMI N.T.S. OF 7 0 TME A LYNN Mia N L P`ES58705 �T OFA o Fia 0 4� N tN0• � {� NN m+ m m U ++ 4 O �+ U� m • •+ N � �iG� n G �i � N Oi m N t A G N N$ G • � n v � �NueSmmp$$m$N>mom$$$o��S".mo$omm$$$$$$$$$�' P C. b m 0 0 C. m IJ W P U FI C O O ... L N o C O m m L• L. !J C b O fn G IJ C O b b O G v� 1 •mp N fVi m o m o L NN m A$$ m •m0 O N O O o N� i E. U o b b o yy (1� m u io O b o b m NN m U 0$ Urr O$ o b m b L m U iw m O$ U is mm O$$ b o 0 0 O O 0 0 O O o b mm O$$� b b b O � N$S$S$$$$$$$$$o$S$S$$��� b c o 0 o b b o b b o 0 o b b m in o b b b b o o b c b-- m b o 0 o b b b b o b c c o b b b b o b o v m 0 0 $ $ $ $ o $ $ o o S $ o $ m N o � $ $ $ % ,in " S o o $ $ •Yd ,&' $ $ $ S S $ o p S $ $ o o o 0 o b b S $ b $ $ $ $ o $ o � ? � Is i. o g 0 m x o Fff- k m m z v � o 0 0 0 mm OOmm mm mm rn g !c z d o rn Yn a$ m$ R o$ m u$ $� b o io P O b i b o b v o Z m o I' $$$S$$SoBS$$� b o o b c o 0 0 0 0 o v m n �-I Z N m b o o b o 0 0 i.�z� � N C� � 3n N m P m N m• A A O N m N m 0� N m N r D — 41 y pW p 1 �_ • d 3 ;mm L �,��' �oGp S'• 1Pi�"• I�0°i$ tau �9°i' i $ N�$ �i"• i $ NPu � lmgi i a� i i � pe s o o U ie b b kn b U U b o 0 o b b b L b o b- -. o 0 o b o o b o o v 1 o $ o mo" = $ ? $ y $ •mo $ o ,ii [An A mD V. ® �y o U U m o c m o U u e o e o 0 o U o 0 0 - 0 0 0 0 0 0 0 0 0 m Z o $ $ $ o S o $ I $ B. $ $ S m $ $ $ $ S $ $ o ? O b b b m o V O O o b N i P A O b o b b O b 0 b b b b b- b- ^ I B o $ o w $ $ $ o Q0u o $ $ $ o $ $ $ d H o b b fo o v o 0 0 o to i i P b o o b b o b b b b b b b o b b os ......... ��''3•N o G'•Ol �� � Z ° D m Yr ;o m� � z� �11• r 3/16' ANN. GLASS 075- INTERLAYER 3/I6- HEAT STREN'D GLASS ,075' INTERLAYER Saflex CP With PET Core SaOex CP With PET Coro By 'Eastman Chemical Co.' BR'Eastman Chemical Co.' OR O 090' INTERLAYER 090' INiERLAYER SaOex Clear And Color Gloss SaBex Clear And Color Class By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' OR R 090' Intertayer .090' InteHayar SentryGlas SentryGlas By 'Kurarcy America, Inc.' Kummy America, Inc.' BR 090' Interiayer .090' Interlayer Trosltol PVB Tr Tro0Uol PVB By 'Kuroray America, Inc.' By 'Kummy America, Inc.' 3/16' HEAT STREN'D GLASS m SILICONE m 3/16' HEAT STREN'D GLASS 2E g 1 I GE 1200 1 DOW CORNING ING 899 :I 2! g tt I •I :I CONE I' SILIGE 126E 1 n u 1 I' Ij DOW CORN NG 995 II DOW CORNING 983 n cs E3 Ij , II jl DOW CORNING 699 II r1 I, i! :j H DOW CORNING 995 . f-1 DOW CORNING 983 �AI/4INTS ON UTES WIDER THAN 36' GLASS TYPE 'C' 7/16' OVERALL LAM. GLASS (L.M.I. & 3/16' ANN, GLASS .075' INTERLAYER SaOex CP With PET Core 3/8' AIR SPACE By 'Eastman Chemical Co.' 3/8' AIR OR .090'� INTERLAYER 3/16' HEAT STRENb GLASS Sonex Clear And Color Glass 3/16- HEAT SfREN'D GL BR'Eastman Chemical Co.' O .090' Interiayer SentryGlas By 'Kuraroy America. Inc.' OR ,090' Intedayer Trosifol PVB By 'Kuroray America, Inc.' m 3/16' HEAT STREN'D GLASS Z n SILICONE GE 120E Ij II II DOW CORNING 899 < n jl jl DOW CORNING 995 :1 �i N :i DOW CORNNG 983 MS "T��/M171KCJKTI�`CN UTES WIDER THAN 36' 1' OVERALL INSUL LAM. GLASS (L.M.I. ONLY) AT 1/4 NON UTES WIDER THAN 36' GLASS TYPE V. 7/16' OVERALL LAM. GLASS 6' HEAT STREN'D GLASS .075" INTERLAYER So ex CP With PEr Core SILICONE By 'Eastman Chemical Co.' GE 1200 OR Ci DOW CORNING 899 090' INTERLAYER O DOW CORNING 995 Saflex Clear And Color Glass Z ;j :j DOW CORNING 983 BR 'Eastman Chemical Co.' O 2 a �j .i lts !I !j !I !j !I .0g0ar ' Interla y n 11 II II SantryGla. By 'Kuroray America, Inc.' OR N4 .D90' Intedayer� Trosifol PVB By 'Kuroray America, Inc.' SILICONE GEM. ' DOW CORNING 899 3/16' HEAT STREN'D GLASS DOW CORNING 995 !I !I SILICONE DOW CORNING 983 ii I! GE 1200 OPTIONAL GLAZING DETAIL jl jl DOW CORNING 899 I'I DOW CORNING 995 GLASS TYPES 'CI' & 'DI' DOW CORNING 983 C MS /lfNED. Tr6e: t.v.n W. GLASS TYPE 'DI' SENTINEL 130 ALUM FIXED WINDOW (L.M.I.)(S.M.I.) AGK 1' OVERALL INSUL LAM. GLASS PssrnAton: Date: GLAZING DETAILS 5/22/19 Recision: Rev. By: I (S.M.I.) ORIGINAL ISSUE IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING EXTERIOR PLY OF GLASS TYPES 'Cl' & 'D1' MUST BE TEMPERED, se"`e/M°a`L: FuaLe: sheet Oovrq Na Rs PW-130 LMI N.T.S. 4 EF 7 PW130LMI-NOA 0 PRODUCT REVISED as canTlying with the FIMMA Buildmq Carla gaoepteaee� wA ®Impact Resistant ���`��l j 1Y LYIft Windows'&Doors ''t1cENgF •,l�� 1m�sltmGm- - Q�• •.� NO, 58705 rrc srs.nt.ran 1 r.c suan.nn — '• �' PREPARED BY LYNN MILLER = •fl y 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 i��••• ATE (941)48D•16D0 cowaimee M. n�uMGGrcars�R SERVED CERT. OF At fl29288 A LYNN Ml0,10 .11P E.0 58705 TYPICAL EDGE DISTANCE TYPICAL INSTALLATION DETAILS INTO CONCRETE AND MASONRY = 2 1/2" MIN. WOOD AT HEAD, SILL OR JAMBS SG - 0.55 MIN CONCRETE HEAD, SILL OR JAMBS 3PSI MIN. THESE DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW INTO WOOD STRUCTURE = 1" MIN. S C-90 HOLLOW/FILLEDHOLLOW/FILLED BLOCK AT JAMBS f'm- 2000 PSI MIN. INTO METAL STRUCTURE = 3/4" MIN. INSTALLATION DETAILS THRU 1X INSTALLATION DETAILS THRU 2X INSTALLATION DETAILS INSTALLATION DETAILS INTO METAL WOOD BUCKS INTO CONCRETE BUCKS OR INTO WOOD STRUCTURES DIRECTLY INTO CONCRETE STRUCTURES OR INTO APPROVED MULLIONS FLANGE FLANGE TYPICAL ANCHORS FLANGE 1/4" MAY I �TGE SEE EIEV• 2Bf WOOD BUCK FOR SPACING SHIMS j I I I OR METAL jj JI WOOD STRUCiU TYPICAL STRUCTURE j! j! M2 9 SEE EDP FOR SPACWC M2 !.v �'' TYPICAL ANCHORS SEE ELEV. Ij Ij © 52 � O I ,� O ,.♦ FOR SPACING = - • v I� El S2 MIt1_ ' • v o' TYPICAL APTCHORS !! !I M2 •�' ^' 1 SEE ELEV. 1BY FOR SPACING II 11 7 WOOD BUCK •v ,;, E1 E3 RODUCTREMSD 1/4' MAY. .• s mmpIyiv8Wfthft FI0'i& SHIMS .a. 3uildeig Code EQUAL LEG EQUAL LEG EQUAL LEG EQUAL LEG B !! I! °I 2BY WOOD BUCK WOOD STRUCTURE A O .♦ N2 C 1 METAL By STRUCTURE Mi®i N'Canito 1 E3 !j !j jj II M2 _ TYPICAL ANCHORS SEE ELEV. II II � z I � FOR SPACING M3 S2 s � I - rF:C.R TiPICAL ANCHORSSEE ELEV. FOR SPACING 'vAFICHORSE3ANCHORSI SEE ELEV.cFOR SPACING V. W006 BUCK CING TYPICAL ANCHORS: SEE ELEV. FOR SPACING WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. 1/4" DIA. KWIK—CON II BY 'HILTI'(FU-153 KSI, Fy=157 KSI) #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) 1 /4" DIA. ULTRACON BY 'ELCO' (FU-177 KSI, Fy=155 KSI) INTO MIAMI—DADE APPROVED MULLIONS N.' 1xo.n ��``� Y LYNiy Impact Resistant OR SENTINEL 130 ALUM FIXED WINDOW (L.M.I.)(S.M.I.) AGK �� jON • •.. INTO 2BY WOOD BUCKS OR WOOD STRUCTURES Windows t4 DDofs .•' VCENSLc'•. C( INTO METAL STRUCTURES (HEAD/SILL/JAMBS) —1/2" MIN. PENETRATION INTO WOOD 1 11e� p , ; Imto. 1Ymsnm om- (3) THREADS MIN. PENETRATION BEYOND SUBTRATE No.58705�� 1��s�'101t��bi1 e"..• R1�0I. THRU 1BY BUCKS INTO CONCRETE OR BLOCKS TYPICAL INSTALLATION DETAILS 522/19 ALUMINUM: 1/8" THK. MIN (6063—T5 MIN.) ra: me.ua�em I�r.r.�nns�n • *_ 1-1/4" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) STEEL 1/8" THK. MIN. (Fy = 35 KSI MIN.) ReNstom Ra By: Rev. Dob: PREPAREDMILE R '.,� TECHNOLOGY 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED ORIGINAL ISSUE N.VENICE FL34275 �0�., ATE F ) L9411480-18DO DIRECTLY INTO CONCRETE OF BLOCKS %, (O •FLORIDL`.• seneyoael: scoro: snoee DAB No Rm coPrncHre a �, S C9 w . 1-1/4" MIN. EMBED INTO CONCRETE (HEADS/SILL/JAMBS) AL1RK'"'����D �'�S���ffN���AL E�``� 1 —1/4" MIN. EMBED INTO BLOCKS (JAMBS) PW-130LMI N.T.S. 5 of 7 PW130LMI-NOA 0 CERT. OF AUTH. rzszse A. LYNN MItm',V.kj1 P.E.958705 TYPICAL INSTALLATION DETAILS THESE. DETAILS ARE TYPICAL ON ALL FOUR SIDES OF WINDOW INSTALLATION DETAILS THRU 1X INSTALLATION DETAILS THRU 2X INSTALLATION DETAILS INSTALLATION DETAILS INTO METAL . WOOD BUCKS INTO CONCRETE BUCKS OR INTO WOOD STRUCTURES DIRECTLY INTO CONCRETE STRUCTURES OR INTO APPROVED MULLIONS FLANGE ADAPTOR FLANGE ADAPTOR FLANGE ADAPTOR FLANGE ADAPTOR TYPICAL ANCHORS 1/4' MAX. SEE ELEV. 2BY WOOD BUCK FOR SPACING SHIMS !I !I OR METAL I I• 63 Mz WOOD STRUCTURE A3 TYPICAL ANCHORS '• STRUCTURE I� II II FOR SPACING . Q '' uz t�ANCHORS SEE . • FOR SPACING Q t C3 -- — — ES V S2 ' p TYPICAL AAbHOR3 !� !j M2 ;E ••. I SEE ELEV.' E3 li 1� 1BY FOR SPACING WOOD BUCK 2 3/1 PRODUCE REVI56D Me Florida 1/4 GAP —I HEI BUCK GHT 1/L 4' MAYL 1 osc plyi gwish Dui1d'm8 �° WOOD STRUCTURE NOT BY CGI 1/2' MIN. Ij--OAP 1/2' MIN. 2 3/. B' MIN. DY FIN FRAME M'®' uz eal;Kem ` CAULKING TYPICAL ANCHORS: SEE ELEV. FOR SPACING I Al, #8 SKIS (GRADE 2 CRS) INTO 28Y WOOD BUCKS OR WOOD STRUCTURES WHEN USED THE MIN. WOOD 1-1/4" MIN. PENETRATION INTO WOOD 1 BUCK DEPTH SHALL BE 2%-. THE USE OF DEEPER OR EXTERIOR BEVELED WOODBUCKS IS PERMITTED. NOT BY"�' BUCK WKT<H BUCK WIDTH ' r--------------------i r -_-- MIAMI—WDE COUNTY I I MIAMI—DADS COUNTY APPROVED I I I I I I I APPROVED MUWON I MULLION & MULLION ANCHORS I & MULLION ANCHORS I I SEE SEPARATE NOA I t SEE SEPARATE NOAI TwU D1OW" or. 7.Y/ , II II II SENTINEL AGK mpact HesistTld /(Windows ✓ Doors TCENSF�� �,�.•YLYNN'M•• �, � L_----- II Don: Dote: YIEiiE dIRONOFII^ '•,'f% i I I * No. 58705 — _ TYPICAL INSTALLATION DETAILS, CONT. 52211B i�L fOSO 4f6f0� 14fP fen�.eu Ro°. Sr. Rev. Dot.PREPARED BY LYNN MILLER -D : ♦,/l `'• a' I I --� ORIGINAL ISSUE 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 i�0 '• SATE --- TYPICAL ANCHORS (941)4WI600 �� '•. .......... � FOR SPACING 5°Nn/Nodel: Seofe: SfnaG• Droving N°. Rer. � MIWND9O Ors '��ci,`SS'/O�.G�\ �YY7 p14 x 1' sus. PW-130 LMI N.T.S. 6 of 7 PW13NOLMI NOA 0 " RD Dg REDO I 11AA` CERT. OF AUTH.#29296 A LYNN MILLER. �.�. P.E#58705 2.505 1.99.812 L±T— T.40- E7 FLANGE FRAME 2.505 812 1.495 .995 _5 7YP. 1.335 OTC FLUSH FRAME/FIN FRAME .675 .995 .975 1.184 O GLAZING BEAD (LAM. GLASS) .tzo 95 O5 0 TYP: .Ell 1.184 E4 GLAZING BEAD (LAM. INSUL GLASS 1.130 .065 1.550 1.880 .050 Es 1.395 NAIL FIN ADAPTER 1.395 180 .050 � .065 9 FLUSH FRAME COVER T-L1.000 r•125 S00 M4 GLAZING ANGLE (LAM. INSUL GLASS) 1.450 180 .050 .550 O FLANGE ADAPTOR - 1.119 .291 .050 4,,081 9 SCREW COVER rrW PART / QUANTITY DESCRIPTION NATSBTAL LAND./SUPPLUM/REMARKS E1 CGI-118 4/ WDW. RANGE FRAME 6063—T6 — E2 CGI-119 4/ WOW. RUSH FRAME/FIN FRAME 6063—TS — E3 CGI-121 4/ WDW. GLAZING BEAD (LAM. GLASS) 6063—T6 — E4 CGI-123 4/ WOW. GLAZING BEAD (LAM. INSUL CLASS) 6063—T6 — E5 CGI-110 4/ WDW. NAIL FIN ADAPTOR 6063—T6 — E6 CGI-109 4/ WDW. FRONT FIANCE ADAPTOR 6063—T6 — Mi CGI-382V AS REOD. GLAZING BULB VINYL PVC OUROMEIER 75—M SHORE A M2 CGI-124 AS READ. SCREW COVER— OPTIONAL PVC — M3 CGI-112 AS REDD. RUSH FRAME COVER PVC — M4 — OPTIONAL GLAZING ANGLE (1 X 1/2 X 1/8) 6063—T5 — M5 — 2/ LITE SETTING BLOCKS EPDM DUROMEIER 8515 SHORE A S2 #10 X 1-1/4' 2/ CORNER ASSEMBLY SCREW PHL PH SMS ST/ST — CIRCULAR WINDOWS RODUCT REVISISD s wmPlYhB with alaFlmida Wilding Coda Aoceptmw No TQ• F 'mtioo Dale �JifhT.bL T WELDED JOINT AT ENDS RECT. OR SQUARE WINDOWS �. CORM SCORMDETAII S SENTINEL 130 ALUM FIXED WINDOW (L.M.1.)(S.M.I.) AGK Deptlon: D.W. EXTRUSIONS, BOM 5=19 ReWion: Rev. By. Rev. ORIGINAL ISSUE Senoa/Nodel: Swlo: ShaoG OrorHn9 No. PW-130 LMI N.T.S. 7 of 7 PW730LMI-NOA 1111111/ Resistant LYNAI `��`\l,ONY .... ®Impact Windows & Boars w¢M BTIW1166P vcENSF •,!� . � P:• .'p � NO' 58705 •' r.r: aae.as.asao 1 au: soe.eaa.au — � PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE � •, Z'� I .• � N. VENICE. FL34275 (941)480-1600 0 STATE F.' ����C�('1:;c<ORIDP.: • \2� ,�� V/O•••••• ����`• tar Cd "I0496 "is 0 ALLRGH8RE5ERVE0 �N11110 CERT.OFAUTH.M29298 A. LYNN MILLER, P.E. P.E958705