HomeMy WebLinkAboutProject InformationManual S Compliance Report Job: 34170720R ARev2 -�- wrightsoft p p Date: Sep 2, 2020 AHU #1 By: EEs Inc. Efficient Energy Services, Inc. P.O. Box 181,AItoona, FL 32702 Plane: 352-669-9090 Email royetficierterergy@gmail.eom Web: wmefidertenergyserviceanccom Project• • For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Cooling Equipment Design. Outdoor design DB: 90.4°F Sensiblegain: 24920 Btuh Outdoor design WB: 77.4°F Latent gain: 8734 Btuh Indoor design DB: 75.0°F Total gain: 33655 Btuh Indoor RH: 50% Estimated airflow. 1200 cfrn Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer. GEOTHERMALH/P [eq Model: NSVO36H101CTLOBN+NSVO36H101CTLOBN Actual airflow. 1200 dm Sensible capacity: 24938 Btuh 100%of load Latent capacity: 8762 Btuh 100% of load Total capacity: 33700 Btuh 100% of load SHR: 74% Heating Equipment Design. Outdoor design DB: 41.0°F Heat loss: 0 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Entering coil DB: 75.8°F Entering coil WB: 63.6°F Entering coil DB: 70.0°F Equipmenttype: SpIitASHP Manufacturer. GEOTHERMALH/P [eq Model: NSV036H101CTLOBN+NSVO36H101CTLOBN Actual airflow. 1200 cfm Output capacity: 24400 Btuh 0% of load Capacity balance: 0 OF Supplemental heat required: 0 Btuh Economic balance: 0 OF Backup equipment type: Sec strip Manufacturer: GEOTHERMAL H/P Model: NSV036H101CTL08N Actual airflow. [egd2M bet* j Output capacity: 5.0 kW 0% of load Temp. rise: 13 OF Meets all requirements ofACCA Manual S. -- wrigl7tsOftm - 2020-Sep-02143425 A� RigffiSute®Universal 201919.0 20 RSU14887 Page 1 ...020194170720R1A_MAINHOUSEl94170720R ARev2.rtp Ca1c=Md8 Front Door faoes: W Manual S Compliance Report Job: 3417072OR ARev2 - wrightsoft° p P Date: Sep 2, 2020 AHU #2 By: EES Inc. Efficient Energy Services, Inc. P.O. Box 181,AItoona, FL 32702 Phone: 352-669.9090 Email: royeffidertenergy@gmail.com Web: vmweffidertenergyseNcesirc.com Project• • For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 24918 Btuh Outdoor design WB: 77.4°F Latentgain: 8730 Btuh Indoor design DB: 75.0°F Total gain: 33648 Btuh IndoorRH: 50% Estimated airflow. 1200 c1m Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer. GEOTHERMALH/P [eq Model: NSZ036H101CNNOBA+NSZO36H101CNNOBA Actual airflow. 1200 cfm Sensible capacity: 24938 Btuh 100% of load Latent capacity: 8762 Btuh 100% of load Total capacity: 33700 Btuh 100%ofload SHR: 74% Heating Equipment Design. Outdoor design DB: 41.0°F Heat loss: 0 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Entering coil DB: 75.2°F Entering coil WB: 62.8°F Entering coil DR 70.0°F Equipmenttype: SpIitASHP Manufacturer. GEOTHERMAL H/P [eq Model: NSZ036H101CNNOBA+NSZO36H101CNNOBA Actual airflow. 1200 cfrn Output capacity: 24400 Btuh 0% of load Capacity balance: 0 OF Supplemental heat required: 0 Btuh Economic balance: 0 OF Backup equipment type: Elec strip Manufacturer: GEOTHERMAL H/P Model: NSZ036H101CNN0BA Actual airflow. [egdW&beW Output capacity: 5.0 kW 0% of load Temp. rise: 13 OF Meets all requirements ofACCA Manual S. wrightsoft- 2020-Sep-0214:3425 RigttSUte®Urtuersal201919.020RSU14887 Page 020%34170720RIA_MAINHOUSE%34170720R ARev2.nrp Calc=MJ8 FrortDoorfaees: W -d- wrightsoftLoad Short Form Entire House Efficient Energy Services, Inc. P.O. Box 181 ARoona, FL 32702 Pbone:352-669-9090 Email: royeffidertenergy@gmail.com Web: wwweffidentenergyservioesiMOM Project• • For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Job: 3417072OR A Rev2 Date: Sep 2, 2020 By: EES Inc. Design Information Htg Clg Infiltration Outside db (OF) 41 90 Method Simplified Inside db (OF) 70 75 Construction quality Semi -tight Design TD (OF) 29 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 5 57 HEATING EQUIPMENT Make Na Trade n/a Model n/a AHRI ref n/a Efficiency n/a Heating input Heating output 0 Btuh Temperature rise 0 OF Actual airflow 0 cfm Airflowfactor 0 cfmA3tuh Static pressure 0 in H2O Space thermostat n/a COOLING EQUIPMENT Make n/a Trade n/a Cond Na Coil n/a AHRI ref n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual airflow 0 cim Airflowfactor 0 cfTdBtuh Static pressure 0 in H2O Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (cfirn) (dm) AHU #1 1461 0 23946 0 1200 AHU #2 1290 0 24918 0 1200 Entire House 2751 0 47986 0 2400 Other equip loads 0 975 Equip. @ 1.00 RSM 48960 Latent cooling 15239 Tf1TAl �- n79, n an100 n 7dnn v I r1 %j Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Sep-0214:3425 -- wrightsoft- Right-Sute®Universal 201919.020 RSU14887 Page 1 /9CCA ...020'94170720R1N hMINHOUSE04170720R ARev2.np Cafc=MJB Front Door faces: W -F�d- wrightsoftLoad Short Form AHU #1 Efficient Energy Services, Inc. P.O. Box 181,Altoorm, FL 32702 Phone:352-6W9090 Email: royeffidertenergy@gmail.com Web: www.efidertenergyservkesir corn r-toject intormation For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Job: 34170720R A Rev2 Data: Sep 2, 2020 By: EES Inc. Design Information Htg Clg Infiltration Outside db (°F) 41 90 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (OF) 29 15 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gdlb) 2 57 HEATING EQUIPMENT Make GEOTHERMAL H/P [equal or better] Trade GEOTHERMAL Model NSV036H101CTLOBN AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat Capacity balance point = 0 OF 8.2 HSPF 24400 Btuh @ 47°F 19 OF 1200 clrn 0 cfmBtuh 0.50 in H2O COOLING EQUIPMENT Make GEOTHERMAL H/P [equal or better] Trade GEOTHERMAL Cond NSV036H101CTL0BN Coil NSV036HIOlCTLOBN AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio Backup: GEOTHERMAL HIP [equal or better] NSV036HI01 CTLOBN NSV036HI01 CTLOBN inns rt = A LAAI 01 Ifni A =17091 Rh ih 100 AFl1F 15 SEER 24938 Btuh 8762 Btuh 33700 Btuh 1200 cfm 0.050 cfmBtuh 0.50 in H2O 0.74 ROOM NAME Area (jtZ) Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF (m) Foyer 155 0 2243 0 112 Great RM 360 0 8574 0 430 Kitchen 250 0 3887 0 195 Laundry_Hail 120 0 2191 0 110 Lounge 380 0 5339 0 268 Powder RM 46 0 572 0 29 e—:__ A[- -Ian n 11,40 n 57 JWj1Q/-WVV11 Calculations approved byACCAto meetall requirements of Manual J 8th Ed. -Fk wrightsoa 2020-Sep-0214:3425 ft,,, Right-Sate®Urtversal201919.0.20RSU14887 Paget /9C�liPt ...020%34170720RW MAINHOUSE\34170720R ARev2.r p Calc=MJ8 FrontDoorthoes: W AHU #1 1461 0 23946 0 1200 Other equip loads 0 975 Equip. @ 1.00 RSM 24920 Latent cooling 8734 Tr1TAl Q 1212RAR n 11)nn V Irwd-j I-tv 1 v vvvvv v .w�. Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightSofto 2020Sep-0214:3425 Right-Slite®Uriversal 201919D.20 RSU14887 Page 3 ...020134170720R1A MAINHOUSE134170720R ARev2np Calc=MJ8 FrortDoorfaces: W wrightsoft° Load Short Form AHU #2 Efficient Energy Services, Inc. P.O. Box 181,AItooro, FL 32702 Phone:352-669-9090 Email: royeffidertenergy@gmail.com Web: wwweffidentenergyservicesimo m For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Htg Clg Job: 3417072OR A ReV2 Date: Sep 2, 2020 By: EES Inc. Infiltration Outside db (°F) 41 90 Method Inside db CF) 70 75 Construction quality Design TD (OF) 29 15 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference (gr4b) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Simplified Semi -tight 0 Make GEOTHERMAL H/P [equal or better] Make GEOTHERMAL HIP [equal or better] Trade GEOTHERMAL Trade GEOTHERMAL Model NSZ036H101CNNOBA Cond NSZ036H101CNN0BA AHRI ref Coil NSZ036H101CNNOBA AHRI ref Efficiency 8.2 HSPF Efficiency 15 SEER Heating input Sensible cooling 24938 Btuh Heating output 24400 Btuh @ 47°F Latent cooling 8762 Btuh Temperature rise 19 OF Total cooling 33700 Btuh Actual airflow 1200 cfm Actual airflow 1200 cfi71 Airflowfactor 0 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Capacity balance point = 0 OF Backup: GEOTHERMAL H/P [equal or better] NSZ036H1 01 CNNOBA NSZ036H101CNNOBA Innr it = A LAN nr Am if = MA 1 Rh rh 1 nn API IF ROOM NAME Area M Htg load (Bluh) Clg load (Bluh) HtgAVF (CIM) CIgAVF (clm) Bath 2 65 0 1607 0 77 Bedroom 2 232 0 3747 0 180 Exercise RM 158 0 2516 0 121 Loft 147 0 1429 0 69 Master Bath 200 0 3213 0 155 Master Bedroom 318 0 4416 0 213 Master WIC 80 0 1199 0 58 Stairs Below 55 0 5931 0 286 1A11r% O 4G n Dal n A 4 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsofta 2020-Sep-0214:3425 Rigtt-Sute®Uriversal 201919.020 RSU14887 Page 4 AFF-- A ...02013417O720RA MAINHOUSEX3417072OR ARev2.np CaIc=MJ8 FrortDoorfaces: W AHU #2 1290 0 24918 0 1200 Other equip loads 0 0 Equip. @ 1.00 RSM 24918 Latent cooling 8730 Tf1TAl Q ,)on n 44RAR n 19nn % J 1 rv-Q Calculations approved byACCA to meet all requirements of Manual J 8th Ed. '' wrightsofta 2020Sep-0214:3425 1 WghFSlite®Uriversal201919.0.20RSU14887 Page ...020134170720RIA MAINHOUSE\94170720R ARev2.nip Calc=MJB FrortDoorfaces: W -- wrightsoft Project Summary Entire House Efficient Energy Services, Inc. P.O. Box 181,AItoona, FL 32702 Phone:352-669-9090 Email: royeffidertenergy@gmail.com Web: v wtetfidertenergyservicesnccom For Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Notes: Main House Design Information Weather. St Lucie Cc Intl, FL, US Job: 34170720R_A Rev2 Dabs: Sep 2, 2020 By- EES Inc. Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 46914 Btuh Ducts 0 Btuh Duds 1072 Btuh Central vent (0 cfm) 0 Btuh Central vent (58 cfm) 975 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 0 Btuh Use manufacturer's data y Rate/swin multipplier 1.00 Btuh Infiltration Equipmengsensibleload 48960 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 12612 Btuh Ducts 2628 Btuh Central vent (58 cfm) 2225 Btuh Heating Cooling 15239 Btuh Area (fF) 0 27A Equipment latent load Volume (ft?) 0 26109 Airchanges/hour 0.41 0.11 Equipment Total Load (Sen+Lat) 64199 Btuh Equiv. AVF (cfm) 0 48 Req. total capacity at 0.70 SHR 6.8 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating Input Sensible cooling 0 Btuh Heating output 0 Btuh Latentcooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 0 dm Actual airflow 0 cfm Airflowfactor 0 cfm/Btuh Airflowfactor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrrigtitsoft� 2020-Sep-02143425 1+ .....•, .. _,� Rfgtt-sat ouriversal201919.020 RSU14887 Page 1 AC.ti.P+ ...020134170720RIA MAINHOUSE134170720R ARev2.nip CaIc=NW8 FrortDoorfaces: W -�- wrightsoftProject Summary AHU #1 Efficient Energy Services, Inc. P.O. Box 181,AItoona, FL 32702 Ptare:352-669-9090 Email: royeffidertenergy@gmail.com Web: wmeifidertenergysenricesnc.com For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Rotes: 1 _ - Design Information Job: 3417072OR A Re12 Date: Sep 2, 2020 By: EES Inc. Weather. St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 23452 Btuh Duds 0 Btuh Ducts 494 Btuh Central vent (0 cfm) 0 Btuh Central vent (58 cim) 975 Btuh Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 0 Btuh Use manufacturer's data y Rate/swin multiplier 1.00 Infiltration Equipmenq sensible load 24920 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 5150 Btuh Duds 1359 Btuh Central vent (58 ctm) 2225 Btuh Heating Coolin Outside air Area (fib 0 1469 Equipment latent load 8734 Btuh Volume (ft3 0 13991 Airchanges/hour 0 0.10 Equipment Total Load (Sen+Lat) 33655 Btuh Equiv AVF (cfm) 0 24 Req. total capacity at 0.74 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make GEOTHERMAL H/P [equal or better] Make GEOTHERMAL H/P [equal or better] Trade GEOTHERMAL Trade GEOTHERMAL Model NSV036H101CTLOBN Cond NSV0361-1101CTLOBN AHRI ref Coil NSV036H101CTL0BN AHRI ref Efficiency 8.2 HSPF Efficiency 15 SEER Heating input Sensible cooling 24938 Btuh Heating output 24400 Btuh @ 47°F Latent cooling 8762 Btuh Temperature rise 19 OF Total cooling 33700 Btuh Actual airflow 1200 cim Actual airflow 1200 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Capacity balance point= 0 OF Backup: GEOTHERMAL H/P [equal or better] NSV0361-1101 CTLOBN NSV036H101 CTLOBN Input = 5 kW, Output =17061 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2020Sep-0214:3425 1�►+'� RigkSUte® Universal 201919.020 RSU14887 Page 2 ...020�34170720RIA MAINHOUSE�34170720R ARev2.np Ca1c=MJ8 FrontOoorfaces: W -�- wrightsoft Project Summary AHU #2 Efficient Energy Services, Inc. P.O. Box 181,Alloora,FL32702Phone: 352-669-9090 Email: royeffidertenergy@gmail.00mWeb: wwKeffidertenergyservicesincoom For Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Notes: Main House Weather. St Lucie Co Intl, FL, US Job: 3417072OR A Rev2 Date: Sep 2, 2020 By: EES Inc. Winter Design Conditions Summer Design Conditions ' Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L " Relative humidity 50 % Moisture difference 57 gr ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 24320 Btuh Ducts 0 Btuh Ducts 598 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 0 Btuh Use manufacturer's data y Infiltration Rate/swin multipplier Equipmengsensibleload 1.00 24918 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight " Fireplaces 0 Structure 7461 Btuh Ducts 1269 Btuh Central vent (0 cfm) 0 Btuh • Heating Cooling (none) 8730 Btuh Area ( ) 0 U ftz Equipment latent load Volume (IF) 0 12110 Airchanges/hour 0 0.12 Equipment Total Load (Sen+Lat) 33648 Btuh Equiv. AVF (cBn) 0 24 Req. total capacity at 0.74 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make GEOTHERMAL H/P [equal or better] Make GEOTHERMAL HIP [equal or better] Trade GEOTHERMAL Trade GEOTHERMAL Model NSZ036H101CNN0BA Cond NSZ036H101CNN0BA AHRI ref Coil NSZ036H101CNN0BA AHRI ref Efficiency 8.2 HSPF Efficiency 15 SEER Heating Input Sensible cooling 24938 Btuh Heating output 24400 Btuh @47°F Latentcooling 8762 Btuh Temperature rise 19 OF Total cooling 33700 Btuh Actual airflow 1200 cfm Actual airflow 1200 cfm Air flowfactor 0 cfm/Btuh Airflowfactor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Capacity balance point = 0 OF Backup: GEOTHERMAL HIP [equal or better NSZ036H101 CNNOBA NSZ036H101 CNNOBA Input = 5 kW, Output =17061 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrigFftsoft® A..• .• Rgk Sute®Urtversa1201919.020 RSU14887 2020-Sep-0214:3425Page 3 ...02013417072ORIAMAINHOUSE%3417072OR ARev2.np Calc=MJ8 FrortDoorfaces: W Duct System Summary Job: 3417072OR A Re12 -I`�- wrightsoft° y ry Date: Sep 2, 2020 AHU #1 By: EES Inc. Efficient Energy Services, Inc. P.O. Box 181,AItoore, FL 32702 Phone:352-669-9090 Email: royeffidertenergy@gmail.com Web: wwweffidertenergyservicesinccom For. Charette Residence 633 SE Hidden River Drive, Port St. Lucie, FL 34983 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowestiriction rate .Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.262 / 0.078 in H2O 0.105 in/100ft 1200 cfm 325 ft Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.262 / 0.078 in H2O 0.105 in/100ft 1200 cfm Name Design (Biuh) Htg Orn) Cig (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Powder RM c 625 0 30 0.105 4.0 Ox 0 VIFx 75.0 175.0 SO Larmdry_Hall c 1775 0 85 0.105 6.0 Ox 0 VIFx 75.0 175.0 SO Kitchen c 3010 0 145 0.105 8.0 Ox 0 VIFx 75.0 175.0 st1 Lounge -A c 3010 0 145 0.105 8.0 Ox 0 VIFx 75.0 175.0 st1 Louse c 3010 0 145 0.105 8.0 Ox 0 VIFx 75.0 175.0 st1 Foyer c 1969 0 95 0.105 6.0 Ox 0 VIFx 75.0 175.0 St2 Stairs Above c 1969 0 95 0.105 6.0 Ox 0 VIFx 75.0 175.0 S12 GreatWA c 2388 0 115 0.105 7.0 Ox0 VIFx 75.0 175.0 S12 GreatRM c 2388 0 115 0.105 7.0 Ox0 VIFx 75.0 175.0 St2 GreatRM-C c 2388 0 115 0.105 7.0 Ox0 VIFx 75.0 175.0 st2 Great RWB c 2388 0 115 0.105 7.0 Ox0 VIFx 75.0 175.0 st2 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (dm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 1200 0.105 800 15.4 18 x 12 RectFbg P st2 PeakAVF 0 650 0.105 650 12.2 12 x 12 RectFbg st1 P PeakAVF 0 1,200 0.105 800 15.4 18 x 12 RectFbg wrightsoTt® 2020-Sep-0214 3425 %� .w..•re. an ��, RightSuite®Universal 201919.0.20RSU14887 Pagel ...020\94170720R1A MAINHOUSE'34170720R ARev2.np Calc=W8 Front Door faces: W Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (afm) (cfm) 01) FR (fpm) (in) (n) Opening (in) Mat! Trunk rb1 18x 30 0 1170 75.0 0.105 662 18.0 Ox 0 VIFx rt1 rb0 Ox 0 0 30 75.0 0.105 345 4.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 0 1200 0.105 686 16A 18 x 14 RectFbg R R PeakAVF 0 1200 0.105 686 15A 18 x 14 RectFbg -�- wrightsoft' 2020-Sep-02143425 �y+�.A LN/GwWn.Woq<nnpa� Mgk Sate® Uriversal 201919.020 RSU14887 Page TiVt1...020'34170720R1A_MAINHOUSE04170720R ARev2.rp Calc=MJ8 FrontDoorlaces: W Duct System Summary Job: 34170720R_ARev2 -�- wrightsoft° y Date: Sep 2, 2020 AHU #2 By: EES Inc. Efficient Energy Services, Inc. P.O. Box 181,AItoora, Fl. 32702 Phone:352-669-9090 Email: royetfidertenergy@gmail.com Web: wwwetfidertenergyservicesncoom For. Charette Residence 633 SE Hidden River Drive, Port St Lucie, FL 34983 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate . Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.240 / 0.100 in H2O 0.100 in/100ft 1200 cfm 340 ft Supply Branch Detail Table Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.240 / 0.100 in H2O 0.100 in/100ft 1200 cfm Name Design (E tuh) Htg (ctm) Clg 0m) Design FR Diam (n) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Master Bedroom. -A c 2393 0 115 0.100 7.0 Ox0 VIFx 65.0 175.0 s12 Master Bedroom c 2393 0 115 0.100 7.0 Ox0 VIFx 65.0 175.0 st2 Loft c 3640 0 175 0.100 8.0 Ox 0 VIFx 65.0 175.0 st3 Exercise RM c 2486 0 120 0.100 7.0 Ox 0 VIFx 65.0 175.0 st3 Master Bath c 2491 0 120 0.100 7.0 Ox0 VIFX 65.0 175.0 St2 Masterroilet c 722 0 35 0.100 4.0 Ox 0 VIFX 65.0 175.0 st2 MasterWIC c 1030 0 50 0.100 4.0 Ox0 VIFX 65.0 175.0 st2 Stairs Below c 3640 0 175 0.100 8.0 OX 0 VIFX 65.0 175.0 st3 WIC c 830 0 40 0.100 4.0 Ox0 VIFx 65.0 175.0 st4 Bathe c 1353 0 65 0.100 5.0 Ox0 VIFX 65.0 175.0 st4 Bedroom c 1970 0 95 0.100 6.0 Ox0 VIFx 65.0 175.0 St4 Bedroom 2-A c 1970 0 95 0.100 6.0 OX 0 VIFx 65.0 175.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfrn) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 0 435 0.100 554 12.0 0 x 0 VinIFIX st1 st3 PeakAVF 0 765 0.100 548 16.0 0 x 0 VinIFIX st1 st4 PeakAVF 0 295 0.100 541 10.0 0 x 0 VinIFIX st3 SO PeakAVF 0 1200 0.100 771 15.5 16 x 14 RectFbg P P PeakAVF 0 1200 0.100 771 15.5 16 x 14 RectFbg wrightsofr"t' ttSute@Uriversal20l9l9.O20RSU14887 1 ��muk•rw.o.v 9 ...020134170720R1A MAIN HOUSE134170720R ARev2.rp Calc=MJ8 Front Door faces: W 2020-Sep-0214:3425 Page 3 Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (dm) (cfm) M FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 14x 10 0 295 100.0 0.100 541 10.0 Ox 0 VIFx rig rb1 16x 12 0 400 100-0 0.100 509 12.0 Ox 0 VIFx rt1 rb3 5x 32 0 351 100.0 0.100 446 12.0 Ox 0 VIFx rt2 rb4 12x 5 0 120 100.0 0.100 448 7.0 Ox 0 VIFx rt1 rbO Ox 0 0 35 100.0 0.100 398 4.0 Ox 0 VIFx rt1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 0 1200 0.100 675 15.5 16 x 16 RectFbg R R PeakAVF 0 1200 0.100 675 15.5 16 x 16 RectFbg rt2 PeakAVF 0 645 0.100 604 14.0 0 x 0 VinlFlx rt1 -�- wrightsofta 2020Sep-02142425 .t ,.,,„,d,,,,,,,.o , RigttSute®Udversal201919.020RSU14887 Page ...020134170720R%A MAINHOUSEl94170720R ARev2.rup Carc=NUB FrortDoorfaces: W