Loading...
HomeMy WebLinkAboutProduct Approval 2/5/2021 Florida Building Code Online Business a Professional ' 1 ; A ` Regulation am + . , ❑❑ BCIS Home I Log In i User Registration I Hot Topics Submit Surcharge I Stats&Facts I Publications I Contact Us ( BCIS Site Map I Links I Search I rI rProduct Approval IUSER:Public User a Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL29078-R2 Application Type Revision Code Version 2020 0�7y6 ' Application Status Approved REV 3 IEWED FOR Comments Archived CODE C®���f���� `TA L UCIE COUNTY Product Manufacturer CGI Windows and Doors ®�� Address/Phone/Email 10100 NW 25 Street Miami, FL 33172 (305)593-6590 Lmiller@pgtindustries.com Authorized Signature. )ens Rosowski 7F1le � josowski@pgtindustries.com Technical Representative Lynh Miller,P.E. Address/Phone/Email 1070 Technology Dr N Venice,FL 34275 (941)486-0100 Ext21142 [miller@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or'a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the A. Lynn Miller, P.E. Evaluation Report Florida License PE-58705 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 02/19/2023 Validated By Steven M. Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL29078 R2 COI Cert of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM E1300 2009 TAS-202 1994 Equivalence of Product Standards Certified By Sections from the Code https://flor�idabuilding.org/pr/prLapp_dti.aspx?par am=wGEVXQwt.DqugvQUWv761qmM6%2fh'isnRIHFL%2fJoQ422tHDtVscZ%2fqeig%3d%3d 1/2 2/5/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 09/04/2020 Date Validated 09/06/2020 Date Pending FBC Approval 09/21/2020 Date Approved 12/16/2020 Summary of Products FL# Model,Number or Name Description 29078.1 SGD-4025A Non-Impact,Aluminum Sliding Glass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL29078 R2 II SGD-4025A CGI-REV A.pdf Approved for use outside HVHZ:Yes Verified By:A.Lynn Miller, P.E.PE-58705 Impact Resistant: No Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other:Please see the enclosed documents for product FL29078 R2 AE-SGD4025A CGI-Eng Eval.pdf performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. 29078.2 SGD-4130A Impact Resistant,Aluminum Sliding Glass Door Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL29078 R2 1I SGD-4130A-REV A.pdf Approved for use outside HVHZ:Yes Verified By:A.Lynn Miller, P.E.PE-58705 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure: N/A Evaluation Reports Other: Please see the enclosed documents for product FL29078 R2 AE 4130 Door Eng Eval.12d performance information,anchorage details,and anchor type, Created by Independent Third Party: No size,and spacing information. Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida,is an AA/EEO employer.Co right 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1), Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem_. Product Approval Accepts: ®0,5 ® 09® Credit Cartl`� Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqugvQUWv761gmM6%2fhjsnRIHFL%2fJoQ422tHDtVscz%2fgeig%3d%3d 2/2' Urich Engineering, LLC 6154 Newgate Circle Mechanicsburg, PA 17050 717-317-8454 steve@urichengrllc.com October 4, 2017 To Whom it May Concern: Urich Engineering, LLC is owned and operated by Steven Urich, PE. Urich Engineering, LLC and Steven Urich,PE do not have, nor intend to acquire, a financial interest in any company manufacturing or distributing a product listed in this product approval; Urich Engineering, LLC and Steven Urich,PE are not affiliated with any company testing or labeling a product under this approval; Urich Engineering, LLC and Steven Urich,PE do not have, nor intend to acquire, a financial interest in any-company involved in the approval process of the products listed in this product approval. Thank you. Steven M. Urich, PE President `\\�1�UN i nra����'` This rceni:has been electronically signed and';e I d °gLZ' C E k s��+��;� 6y Steveri:Afi Unch:PE on 10%4/2017 'using a Digiial A. .Sagnature;� . 6 * Printed copes of this document are not can;idere& �p STATE OF aigned ands'16 and the signature must- a verified P = on an electronic co ies W ,P Engineering Evaluation Report # 4130-090120 Prepared by: A. Lynn Miller, P.E. 1070 Technology Dr. N.Venice, FL 34275 (941)480-1600 . Certificate of Authorization: #29296 Manufacturer: CGI Windows and Doors 3780 W 104th St. Hialeah, FL 33018 Product Description: SGD4130A Impact-resistant Aluminum Sliding.Glass Door, (LM &SM), FL-29078 Compliance: The above-mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61. G20-3.005 method 1(d). The product listed herein complies with requirements of the current Florida Building Code. This product has been evaluated and is in compliance with the current Florida Building Code, including the"High Velocity Hurricane Zone" (HVHZ). Supporting Technical Documentation: 1.Approval document: drawing number SGD4130FLPA Rev.A, signed and sealed by A. Lynn Miller, P.E. 2. Test Report FTL 19-8800 &20-2108.1-5, signed and sealed by Idalmis Ortega, P.E. Fenestration Testing Laboratories, Medley, FL 33166 TAS 201-94 Large Missile Impact Test TAS 202-94 Uniform Static Air Pressure Test TAS 203-94 Cyclic Pressure Loading Test 3.Anchor calculations, signed and sealed by A. Lynn Miller, P.E.,.dated 4/18/19 &9/1/20 Limitations and Conditions of use: • Units must be glazed per ASTM E1300-09, refer to approval document for glazing details. •This product is rated to be used in-the HVHZ. -This product is impact resistant and does not require impact protection in wind borne debris regions-. • Frame and panel material to be extruded Aluminum. • Units must be installed in accordance with approval document SGD4130FLPA. I,I A,��Ikllf°tlfE/ LYNj1Ghjyoo.',�,� � No 587- 5 , N.. -9!3/20` ;tU Q STATE OF !(/ i yam. A. Lynn Miller, P.E. P.E. #58705 FLORIDA PRODUCT APPROVAL#29078 DESIGN PRESSURE RATING IMPACT RATING SERIES 4130A IMPACT RESISTANT SLIDING GLASS DOOR +55/-65 PSF RATED FOR LARGE a SMALL MISSILE IMPACT RESISTANCE 1)THIS PRODUCT HAS BEEN DESIGNED 8 TESTED TO COMPLY WITH THE REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE,INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). 3ANCHORS FOR ANCHOR , GROUPA(SHOWN); 2)SHUTTERS ARE NOT REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 5 ANCHORS FOR ANCHOR AT LEAST 4"O.C.,STAGGERED GROUPS IN ALTERNATING TRACKS, 3)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE 1.ALL WOOD BUCKS LESS THAN 6"MAX. I►— A SEE SHEET 3 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1XAND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS 6"MAX. TO THE STRUCTURE.WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 4)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. CI USE.ANCHORS OF SUFFICIENT LENGTH.INSTALLATION ANCHORS SHOULD BE SEALED.OVERALL C D E DI SEALINGIFLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5)SHIMS ARE REQUIRED AT EACH FLANGE ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS.WOOD BUCKS,BY OTHERS,MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM 88-5/8" BY THE DOOR. 28-3/4"MAX.O.C.FOR MAX.DLO. ANCHOR GROUP A; 98"MAX' HEIGHT FRAME HEIGHT 6)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WIND LOADS 18"MAX.O.C.FOR CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%STRESS INCREASE HAS ANCHOR GROUP B NOT BEEN USED IN THE DESIGN OF THIS PRODUCT,THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. / TABLE 1: 40-518"MAX Anchor Minimum Minimum DLO WIDTH B Group Anchor Substrate Edge Embedment Distance Southern Pine(SG=.55) 9/16" 1-3/81, _ #12 SMS Screw(G5); Aluminum,6063-T5 min. 3/8" 1/8" FOR SILL ANCHORAGE,SEE HEAD. Steel,18-8 SS or410 - SS Steel Stud,16 Ga.,Gr.33 min. 3/8" 0.0566" A36 Steel 3/a" 0.050^ TYP.ANCHOR LOCATIONS Concrete(min.2.9 ksi) 2-1/2" 1-3/8" 4 PANEL,2 TRACK BYPASS OXXX - 1/4"steel Ultracan Ungrouted CMU,(ASTM G90) 2-1/2" 1-1/4" CONFIGURATION SHOWN. A Southern Pine(SG=.65) 1" 1-3/8" UNLIMITED NUMBER OF PANELS IN ANY 2-TRACK OR 3-TRACK CONFIGURATION USING VERTICAL Concrete(min.3.0 ksi) 2-1/2" laell CONDITIONS SHOWN ON SHEET 2 ARE APPROVED AS LONG AS THE PANEL DLO WIDTH DOES NOT 1/4"steel Ultracon+ Ungrouted CMU,(ASTM C-90) 2-1/2" 1-1/4" EXCEED THE TESTED DLO WIDTH OF 40-5/8"AND THE TESTED FRAME HEIGHT OF 98"IS NOT Southern Pine(SG=.55) 1" 1-3/8" EXCEEDED. Concrete(min.3.35 ksi) 2-1/2" 1-3/4" ADDITIONALLY,FOR INSTALLATIONS IN THE HVHZ,MAXIMUM FRAME AREA OF 194.6 SQUARE FEET, 1/4"410 SS CreteFlex Ungrouted CMU,(ASTM G90) 2-1/2" 1-114" MAY NOT BE EXCEEDED. - Southern Pine(SG=.55) .1" 1-3/8" ,�ttpl!Id7:L1Th/Ij Concrete(min.2.95 ksi) V. 1-3/8" 1l4"steel Ultrecon Ungrouted CMU,(ASTM G90) 1" 1-1/4" 'r��•��•`WOEN�,;"'.��{`��^f,, B 1/4"steel Ultrecon+ Concrete(min.3.0 ksl) 1-5/8" -1-3/8" Impact Resistant Ungrouted CMU,(ASTM G90) V. 1-1/a" n8i' - a°•"W. '�WlndoWS&Doors y, No 5870S: t Concrete(min.3.35ksi) r'. 1-3/4- ALUMINUM SLIDING GLASS DOOR FPA J ROSOWSKI WE'flESTa0N0Ea'- 1/4"410 SS CreteFlex Ungrouted CMU,(ASTM G90) 1-0/4" 1-1/4" D••rviption: Dote: - PREPARED BY LYNN MILLER 1)ANCHOR MUST EXTEND A MIMIMUM OF 3 THREADS BEYOND ANY METAL SUBSTRATE. GENERAL NOTES&ELEVATION 04/15/19 1070 TECHNOLOGY DRIVE2)'UNGROUTED CMU' �` BTATEDF 3)ANY ANCHOR HEAD TYPEES APPLICABLE.S MAY BE D FOR GROUT-FILLED CMU APPLICATIONS. RMo/on: Rev. aY: R•v.Cat.: N.VENICE,FL 34275 (941)480-1600 ADDED ULTRACON+ANCHORS JR 09/01/20 DGlwie PYRIGH oopR,INc. $III.9�nad•/: Seat•: Sh•et: DraWng No. R•r LIMITED LICENSE TO MPNE SGD-4130A NTS 1 OF4 SGD4130FLPA A COPIES FOR PERMITTING. A.LYNN MILLER,P.E. CERT.OF AUTH.#29296 P.E.#58705 EDGE TYP.ANCHOR TYPE,EMBEDMENT AND EDGE PANEL CLIP ONLY USED I-F- 1/4"MAX.SHIM DISTANCE DISTANCE PER SUBSTRATE,SEE TABLE 1,SHEET 1 39 24 IN CONFIGURATIONS WITH A FIXED PANEL 71t DETAIL OAawn EMBEDMENT 114"MAX.SHIM DETAIL O DETAIL C' - DETAIL D'SIMILAR 1p DETAIL C SIMILAR FOR ALL FRAME MEMBERS IN A 3-TRACK CONFIGURATION,THE 2-TRACK HEAD OUTER ROW OF SHOWN,MAY ALSO INSTALLED IN S BE 3-TRACK,#4 _ 30 EITHER THE EXTERIOR OR 30 DLO INTERIOR TRACK. WIDTH 7 26 23 I TYP.ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, 30 SEE TABLE 1,SHEET 1 9 25 8 13 EXTERIOR EDGE DISTANCE 25 27 38 ` EMBEDMENT 28 3-TRACK JAMB SHOWN,MAY FRAME - DLO 6 ALSO BE 2-TRACK#3 HEIGHT HEIGHT DETAIL OE 30 NOTES 37 11 7 1)USE ONLY SUBSTRATE APPROPRIATE ANCHORS 13 w DISTANCE LIMIT LISTED IN S FOLLOW EMBEDMENT AND EDGE 20 2)MASONRY ANCHORS MAYBE USED INTO WOOD AS 32 PER TABLE 1.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X WOOD 50 9 BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD'BUCKS DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS(WHEN EXTERIOR 219_r") EXTERIOR 27 3B 26 USED)SHALL BE DESIGNED TO PROPERLY TRANSFER 22 n LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND FIXED PANEL `J INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER DETAIL @ SILL OR ARCHITECT OF RECORD.. 3)SEE SHEET 3&TABLE 1 FOR SPACING REQUIREMENTS. 2-TRACK SILL SHOWN,MAY 4)MAX.SHIM THICKNESS TO BE 1/4'�, jrl'ta'/J1t ALSO BE ♦\S 7/ 3-TRACK,#5 ♦ � Ell DETAIL B Impact Resistant T1 �, ra.: D"e"" Windows&Doors No 58ZOS. , ALUMINUM SLIDING GLASS DOOR FPA J ROSOWSKI O WE'RE STRONGER" 1/4°MAX. Description: Date: PREPARED BY LYNN M CONT.SHIM EMBEDMENT 1070 TECHNOLOGY DRIVER,r2�, , OR GROUT + INSTALLATION CROSS-SECTIONS 04/15/19 N.VENICE,FL 342756'[ATE OF RMNon: Rev. By: Rev.Dab: �i "- ORIOw•'�1�^' I� EDGE TYP.ANCHOR TYPE,EMBEDMENT AND EDGE CGWINDOWS nTD000Rs,NC. DISTANCE DISTANCE PER SUBSTRATE,SEE TABLE 1,SHEET 1 Seneo/Nodd: Scale: Sheet: Drvwfnq No. Rev: LIMITED LICENSE TO Mace I SGD-4130A .75 2 OF 4 SGD4130FLPA A RT. F AUTH.#29 A.LYNN MILLER,P.E. CERT.OF AUTH.#29296� P.E.#58705 - I 3.826" 3,625" MIN, MIN, 4"MIN. 2 TRACK JAMB 3 TRACK JAMB 4"MIN. + 1 ANCHOR DETAIL .ANCHOR DETAIL ° ° o 0 0 1 1.871" - 1.871" IF F ° EXTERIOR EXTERIOR o - o 1 nn I � + 2 TRACK HEAD V 2 TRACK HEAD 3-ANCHOR CLUSTER DETAIL .5-ANCHOR CLUSTER DETAIL 6"MAX 6"MAX . MMIN: 25" 3.625' 0 0 MIN. 4"MIN. 4"MIN. o o o o I , 1.871" 1.871" 28.314"MAX.O.C.FOR 26-314"MAX.O.C.FOR ° o o ANCHOR GROUP A; ANCHOR GROUP A; EXTERIOR EXTERIOR 18"MAX.O.C.FOR 18"MAX.O.C.FOR ANCHOR GROUP B ANCHOR GROUP B 2-TRACK SILL 2 TRACK SILL n 1 3-ANCHOR CLUSTER DETAIL 5-ANCHOR CLUSTER DETAIL 3.62 MIN.. 3.625" 4"MIN.28-314'MAX.O.C,FOR 28-3/4"MAX.D.C.FOR MIN. ANCHOR GROUP A; .ANCHOR GROUP A; 4"MIN. 18"MAX.O.C.FOR 18"MAX.O.C.FOR o o o o o ANCHOR GROUP B ANCHOR GROUP B 1 871" 1 871" o1 0 'lll EXTERIOR EXTERIOR o 0 3 TRACK HEAD 3 TRACK HEAD 3-ANCHOR CLUSTER DETAIL 5-ANCHOR CLUSTER DETAIL (SEE NOTE 1,THIS SHEET) (SEE NOTE 1#MIN THIS SHEET) 28-314"MAX.D.C.FOR 28-314"MAX.O.C.FOR ANCHOR GROUP A; ANCHOR GROUP A; 3.625° 3.626' 18"MAX.O.C.FOR MIN. MIN, ANCHOR GROUP B 18"MAX.O.C.FOR ANCHOR GROUP B 0 4"MIN, o o 1" EXTERIOR I EXTERIOR o o EXTEERIOR TEERIIOR 3 TRACK SILL 3 TRACK SILL 3-ANCHOR CLUSTER DETAIL 5-ANCHOR CLUSTER DETAIL EXTERIOR INTERIOR, (SEE NOTE 1,THIS SHEET) (SEE NOTE 1,THIS SHEET) TRACK TRACK T\',.,' i� CENTER TRACK Impact Resistant Drawn Qr. ®Windows&Doors No 557NOTE 1) dS, IN KI RE A3-TRACK ALL MEMBERS IN ALUMINUM SLIDING GLASS DOOR FPA J ROSOWS WE STRONGER'"' MEMBE _ CONFIGURATION,THE OUTER Dear+ipaon: Dofa: ROW OF ANCHORS MAY BE . PREPARED BY TECHNOLOGY DR I LYNN MILLER INSTALLATION ANCHOR HOLE LOCATIONS O4/15/19 r-� "Y"•,, Q�3�,z� - 1070 TECHNOVE .C' INSTALLED IN EITHER THE Q t.,_ STATE OF N.VENICE.FL 34275 .(� ti EXTERIOR OR INTERIOR TRACK. Redelon; Rev. Rev.Dab: fig =•.(�ORIOP 6r (941)480-1500 NA CGI WINDOWS AND DOORS,INC. r O Senee/NOAoI: Soule: Sheet: On]wlny No. Rev: LIMITED LICENSE TO MAKE I COPIES FOR PERMITTING' A.LYNN MILLER,P.E. SGD-4130A NTS 3 OF 4 SGD4130FLPA A CERT.OF AUTH.#29296 P.E.MILLER TABLE 2: .062" .062" Item PartM Description Mat 1 4.673' 6.540' +-I 1 AL-1140 2-Track Frame Head 8063-76 T 1 +I .062' �2 AL-1142 2-Track Frame Sill 6063-TB 1.126" 1.125" 3 AL-1141 2-Track Frame Jamb 6063-TB ++ y 4 AL-1143 3-Track Frame Head 6063-Tfi 11-ji .065T 1 .065" = " 1 3.668. 5 AL-1145 3-Track Frame Sill 6063-TG O 2-TRACK HEAD - O 3-TRACK HEAD 6 AL-1144 3-Track Frame Jamb 60WIS 7 AL-1147 Horizontal Stile 6063-TB 4.847" + 6.715" 2.639" 8 AL-1148 Extedor Interlock 6063-T6- .070" 1 .070" 1 9 AL-1150 Vertical Rail 6063-TB .075" 10 AL-1149 Interior Interlock 6063-T6 .875' d Do .874" 11 AL-1151 Astragal 6D63-T6 TI}' 12 AL-1146 Waterbar Adaptor 6063-TB O 2-TRACK SILL OS 3-TRACK SILL 160• 1.404' .647"�- 13 AL-1152 7/16"Laminated Glazing Bead 6063-T6 WATERBAR 14 AL-1153 Roller Track 6083-76 090, •090" 11 ASTRAGAL 12 ADAPTER 20 HD-77-10244 Fixed Panel Shim 4.716" . 90 6.584" 21 HD-77-10245 Roller Shim i I T 22 HD-77-10249 Tandem Rollers t + --►I.680"'I-►- 23 HD.77-10246 Anti Lift-Air Pad 1.375" '�' 870" 24 Fixed Panel Clip 6D63-T5 25 WS-382V Glazing Bulb.187'X.200" PVC .080" + + .045" 1.007" �- .344" 26 Lock - O 27 2-TRACK JAMB .080" O 3-TRACK JAMB Handle-KIT- 28 Handle Set-KIT 13 BEADING 14 ROLLER TRACK -29 Recessed Handle I. 4.062" 4.006" 30 64068G Wea lherstr 1p.187°X.230"Fin Seal 070° 31 HD-77 .95"X 2"X8"(Anti-Lift& Plug 32 PGT 71828K 1/2"X4°X 1/8°Setting Block 11 T 7/16"NOM GLASS STACK 33 204-W Bumper PVC T .070' I 34 7116"Adjustment Screw Cover 1.340° 3116"HEATSTRENGTHENED GLASS 35 #8 X 1"Pan Phil A(Assembly) 41055 11 1.790" 36 #10-16 X 1.1/4"Pan Phil Tek 4109S y .062' + ,090"SAFLEX OR TROSIFOL 37 #10 X5/8"Pan Phil AB(Astragal) 41OSS 1 1 PVB INTERLAYER 38 #10 X 1"Pan PH TEK 410 SS(Keeper) 41OSS OHORIZONTAL RAIL (a)EXTERIOR INTERLOCK 3/16°ANNEALED GLASS OR 39 #8 X314"Flat Phil Tek(O-panel) 41OSS .062" .080' HEAT-STRENGTHENED GLASS ' 40 #10J2 X 314"Flat(Undercut)Ph 41OSS 080" 25 kGL-ASS 41 HD-77-10252 .810"X 1-3116"X.690"(Top/Bot Rail)Plug . 070" 42Dow 791,983 or RGS 7700 Sealant 4.006" I 4.006" 13 50 - Screen Assembly wades .070' .D70" F�CTERIOR1.490" 1.790" . .070" ' .070" OVERTICAL STILE 10 INTERIOR INTERLOCK {f1 '.`t(.kl'l,_'Il/L:/)/ TYP. GLAZING DETAIL &Impact Resistant `Q Rti• D°"" .Windows&Doors _ ND 55705. ALUMINUM SLIDING GLASS DOOR FPA J ROSOWSKI WERE STROWE6'" *�j{ Description: - D•1" PREPARED BY LYNN MILLER~ '�T" /(2Q� EXTRUSIONS AND BOM 04/15/19 1070TECHNOLOGY DRIVE �0 sTAT> of N.VENICE.FL 34275 Rwidon: Rev.By: Rsv.Doter COPYRIGHT-1010 CGIWWWWSIWODOORS,INC. //F�If��NAi;�\`�`J Ssnes/Alodel: Scala: Short: Dm"!ng No. R-, LIMITED LICENSE TO MAKE I SGD-4130A .75 40F4 SGD4130FLPA A COPIES FOR PERMITTING. A.LY1.NMILLER,P.E. CERT.OF AUTH.#29296 P.E.#58706