HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performs c .
KU C llP
Project Name: Lot 36 Block 2 Waterstone 2508 CGR
Builder Name: ADAMS HOME
Street: 8513 Waterstone Boulevard
Permit Office:
FEB 12 ?.020
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000 ST. Lucie County, Permitting
Design Location: FL, ST_LUCIE CO INTL
- -
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type02020.7 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
4. Number of Bedrooms 4
c. N/A
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2603.0 sqft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade (ft2) 2523
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2523.00 ft2
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(293.4 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.223 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
SHGC(AVG): N/A
15. Hot water systems
9. Floor Types (2523.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.31
PASS
Total Baseline
Loads: 71.58
I hereby certify that the plans a cations covered
this
Revie . of the plans and
SHE Sr
9
calculation are in compli c the Flori rgy
Code.
specifications covered by this
1,
yd r = �0
calculation indicates compliance
�'''
PREPARED BY:
with the Florida Energy Code .
Bef
Before
S
•;;. �'`�� `gyp
:• '�,, ..t_
construction is completed
DATE: f11-07-?0�1 A/inn Kenmany
this building will be inspected for
-1!
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
*�
G0
OWNER/AGENT.
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the aie handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
\ 1
,FORM.R405-2020 IIUPI IT cI Innl►nAMr i+u=nlzl 1C•T r.o.m—
PROJECT
Title:
Lot 36 Block 2 Waterstone 25 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2523
Lot #
36
Owner Name:
Total Stories: 1
Block/SubdNision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8513 Waterstone Boule
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL, 34951
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ----
0.44 0 0.56
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2523 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ft2 0.11
Wood
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
- lip Ft
Height
Et
Sheathing Framing Solar Below
1 NW
Exterior
Concrete Block - Int Insul
Main
4.1 48
6
8 0
388.0 ft2
0
0 0.6
0
0
2 NE
Exterior
Concrete Block - Int Insul
Main
4.1 37
2
8 0
297.3 ft2
0
0 0.6
0
3 SE
Exterior
Concrete Block - Int Insul
Main
4.1 51
3
8 0
410.0 ft2
0
0 0.6
0
4 S
Exterior
Concrete Block - Int Insul
Main
4.1 6
2
8 0
49.3 ft2
0
0 0.6
0
5 SW
Exterior
Concrete Block - Int Insul
Main
4.1 37
6
8 0
300.0 ft2
0
0 0.6
0
6 -
Garage
Frame - Wood
Main
13 34
0
8 0
272.0 ft2
0
0.23 0.01
0
- 7 SW
Exterior
Concrete Block - Int Insul
Main
4.1 23
6
8 0
188.0 ft2
0
0 0.6
0
8 NW
Exterior
Concrete Block - Int Insul
Main
4.1 8
6
8 0
68.0 ft2
0
0 0.6
0
9 SE
Exterior
Concrete Block - Int Insul
Main
4.1 6
0
8 0
48.0 ft2
0
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NE
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
3
SE
Insulated
Main
None
.25
2
4
6 8
15.6 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V # Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW
1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2 NW
1
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 NE
2
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 NE
2
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 NE
2
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
6 NE
2
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 SE
3
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 SE
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
9 S
4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 SW
5
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
11 SW
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 SW
7
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft?
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 SW
5
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
1 ft2 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
620 ft2 620 ft2
64 ft
8 ft
1
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Is
Proposed ACH(50)
.000391
2590.3 142.11 266.8 .1312
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
#
F1
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
Central Unit/
Split
Sing] SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None
None
ft2
DUCTS
/
V/ #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling Jan Feb Mar
Heating HJan X Feb Mar
Venting Jan [ Feb X Mar
Ceiling Fans:
Se
APr MayJun Jul AuSep
Apr Ma rj Junrl
Jul rl
Au rl
[X] A r [ Ma Jun JulAug Se [X]
Oct Nov
Oct Nov
Oct HX Nov
Dec
Dec
H Dec
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM-R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
MASS
t
8 9 10 11 12
78
80
80
80
80
78
78
78
78
78
78
78
78
78
78
78
78
78
78
68
68
68
68
68
68
68
68
66
66
68
68
68
68
68
68
68
68
66
66
Mass Type Area Thickness Furniture Fraction
Default(8 Ibs/sq.ft. 0 ftz Oft 0.3
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance
Index, the more efficient the home.
8513 Waterstone Boulevard,
Fort Pierce, FL, 34951
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms 4
d. N/A
R=
ft2
5. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (ft2) 2523
a. Under Attic (Vented)
R=30.0
2523.00 ft2
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows- Description Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33 70.92 ft2
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
13. Cooling systems
kBtu/hr
Efficiency
35.56 ft2
SHGC: SHGC=0.70
a. Central Unit
42.0 SEER:15.00
d. U-Factor: other (see details) 20.83 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth: 6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC: 0.288
8. Skylights Description Area
15. Hot water systems
a. U-Factor(AVG): N/A ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types Insulation Area
b. Conservation features
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
None
b. N/A R= ft2
Credits (Performance method)
Pstat
c. N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: \ = Date:
Address of New Home-
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff. �
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1