HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performs c . KU C llP Project Name: Lot 36 Block 2 Waterstone 2508 CGR Builder Name: ADAMS HOME Street: 8513 Waterstone Boulevard Permit Office: FEB 12 ?.020 City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 ST. Lucie County, Permitting Design Location: FL, ST_LUCIE CO INTL - - County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type02020.7 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 4. Number of Bedrooms 4 c. N/A d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2603.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2523 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2523.00 ft2 R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(293.4 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 6.223 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (2523.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.31 PASS Total Baseline Loads: 71.58 I hereby certify that the plans a cations covered this Revie . of the plans and SHE Sr 9 calculation are in compli c the Flori rgy Code. specifications covered by this 1, yd r = �0 calculation indicates compliance �''' PREPARED BY: with the Florida Energy Code . Bef Before S •;;. �'`�� `gyp :• '�,, ..t_ construction is completed DATE: f11-07-?0�1 A/inn Kenmany this building will be inspected for -1! compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. *� G0 OWNER/AGENT. BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the aie handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 \ 1 ,FORM.R405-2020 IIUPI IT cI Innl►nAMr i+u=nlzl 1C•T r.o.m— PROJECT Title: Lot 36 Block 2 Waterstone 25 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2523 Lot # 36 Owner Name: Total Stories: 1 Block/SubdNision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8513 Waterstone Boule Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2523 22202.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 22202.4 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ft2 ---- 0.44 0 0.56 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2523 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width - lip Ft Height Et Sheathing Framing Solar Below 1 NW Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ft2 0 0 0.6 0 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 37 2 8 0 297.3 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 51 3 8 0 410.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 6 2 8 0 49.3 ft2 0 0 0.6 0 5 SW Exterior Concrete Block - Int Insul Main 4.1 37 6 8 0 300.0 ft2 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.23 0.01 0 - 7 SW Exterior Concrete Block - Int Insul Main 4.1 23 6 8 0 188.0 ft2 0 0 0.6 0 8 NW Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ft2 0 0 0.6 0 9 SE Exterior Concrete Block - Int Insul Main 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 3 SE Insulated Main None .25 2 4 6 8 15.6 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ft2 13 ft 0 in 0 ft 6 in None None 4 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 13 ft 0 in 2 ft 10 in None None 5 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 6 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 7 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 SE 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 9 S 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 10 SW 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 10 in 0 ft 10 in Drapes/blinds None 11 SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 12 SW 7 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft? 9 ft 10 in 0 ft 4 in Drapes/blinds Exterior 5 13 SW 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft2 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ft2 620 ft2 64 ft 8 ft 1 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Is Proposed ACH(50) .000391 2590.3 142.11 266.8 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # F1 System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts Central Unit/ Split Sing] SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / V/ # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Cooling Jan Feb Mar Heating HJan X Feb Mar Venting Jan [ Feb X Mar Ceiling Fans: Se APr MayJun Jul AuSep Apr Ma rj Junrl Jul rl Au rl [X] A r [ Ma Jun JulAug Se [X] Oct Nov Oct Nov Oct HX Nov Dec Dec H Dec 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM-R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 MASS t 8 9 10 11 12 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 78 78 78 78 68 68 68 68 68 68 68 68 66 66 68 68 68 68 68 68 68 68 66 66 Mass Type Area Thickness Furniture Fraction Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 8513 Waterstone Boulevard, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (ft2) 2523 a. Under Attic (Vented) R=30.0 2523.00 ft2 b. Knee Wall (Vented) R=19.0 80.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 13. Cooling systems kBtu/hr Efficiency 35.56 ft2 SHGC: SHGC=0.70 a. Central Unit 42.0 SEER:15.00 d. U-Factor: other (see details) 20.83 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 6.223 ft. a. Electric Heat Pump 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: \ = Date: Address of New Home- City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. � **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/7/2021 12:18 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1