Loading...
HomeMy WebLinkAboutProduct Certification; 407 Vinyl Laminated Outswing DoorAAMA CERTIFICATION PROGRAM r F G I: A An FGIA Product Certification Program `,-sa, r�'rinEa AUTHORIZATION -FOR PRODUCT CERTIFICATION Ekir Door and Metals Co. 1215 Pope Dr. ... Douglas, GA 31533. Attn: Randall Yarberry This authorization- is based on. the successful, completion of tests, and the•reporting to the AAMA Validator of the results of the tests by an. AAMA Accredited Laboratory. The product information below will be added -to the next update of the AAMA Certified Products Directory:. This Certification will expire August 19, 2025 and requires validation until then by continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Construction Consulting Laboratory Report No.: CCL-20467 Date of Report: September 28, 2020 .Evaluated for Certification: January 28, 2021 oci led Laboratories, Inc. Authorized for Certification: January 28, 2021 (ValldatorIOperations Administrator) ...: ACP-04 (Rev. 2/20) Fen' - tion.and Glazing IndustryAlliance � s ELU[IR DOOR & METALS CO. a� MODEL 407 -NON-EIVIPACT OUTSWING O VINYL LANMATED STEEL DOOR a INSTALLATION ANCHORAGE DRAWING [JRI'J I I;L!113-} 1. THE PRODUCTANCHORAGE SHOWN HEREIN 13 DESIGNED 5.IN AREAS WHERE WINDBORNE DEBRIS PROTECTION TO COMPLY WITH THE CURREUr EDITION OF THE REQUIREMENTS EXIST, USE OF AN IMPACT PROTECTIVE FLORIDA BUILDING CODE (FSC) EXCLUDING HIGH. SYSTEM COMPLYING WITH THE FBC REQUIREMENTS FOR VELOCITY HURRICANE ZONE AND THE DESIGN WINDBORNE DEBRIS REGIONS IS MANDATORY FOR THE PRESSURE(S) STATED HEREIN. PRODUCTHEREIN. Im THE PRODUCT DETAILS CONTAINED HEREIN ARE EASED 6: FRAME MATERIAL: ALUMINUM ALLOY /083TS UPON SIGNED AND SEALED TEST REPORT DOOR PANEL MATERIAU .OS MIL VINYL LAMINATED CONSTRUCTION CONSULTING LABORATORY REPORTS GALVANIZED STEELCIS• SIGN W1 URETHANE FOAM CORE CCL411.167 AND ASSOCIATED LABORATORY STAMPED DRAWINGS. T. GUESS MEETS THE REQUIREMENTS OF ASTM EIM0.12AE1. 1b. TESTED TO ASTM E330.14. 2. ADEQUACY OF THE EXISTING STRUCTURAL2.X FRAMING OR STEEL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND ' TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 0. DESIGNATIONS 9C STAND FOR THE FOLLOWING: X:OPERABLE PANEL O: FIXED PANEL 9.HARDWARE A HALF HINGES: (4) GN3.T8 EXTRUDED ALUMINUM B. LATCH LOCK KEYED C. DEAD BOLT: SINGLE CYLINDER 3.1XAND 2X BUCKS WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 10. SEE SHEETI FOR DESIGN PRESSURE CHART. STRUCTURE BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF IT. IF WATER INFILTRATION REQUIREMENT EXISTS; UNIT MUST RECORD. - BE INSTALLED BENEATH AN OVERHANG MEETING THE 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FORA SPECIFIC SITE IF STIE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT, CURRENT EDITION OF THE FLORIDA BUILDING CODE, BUILDING AND RESIDENTIAL VOLUMES. DEMON PRESSURE RATING (PSF) IMPACT RATING WHEREWATERINFILTRATION REQUIREMENTIS NEEDED WHEREWATERINFILTRATION REQUIREMENTIS NOT NEEDED NONE SEE GENERAL NOTE 11 - 0150 TABLE OF CONTENT SHEET DESCRIPTION I GENERAL AND INSTALLATION NOTES 2 ELEVATION. ANCHORING LAYOUT 3 VERTICAL CROSS SECTIONS 4 -- HORIZONTAL CROSS SECTIONS STALLATIONNOTES: 1. ONE (1) INSTALLATION ANCHOR 13 REQUIRED AT EACH ANCHOR LOCATION. 2. THE INSTALLATION ANCHORS AT THE SPACINGS SHOWN ARE THE MINIMUM NUMBER OF ANCHORS AND MAXIMUM SPACINGS TO BE USED FOR PRODUCT INSTALLATION. 3. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM SEZEOF IN INCH. SHIM WHERE SPACE OF 1116 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER 4. ANCHORS FOR INSTALLATION INTO WOOD FRAMING OR 140A. MINIMUM STEEL FRAMING SHALL BE AS SHOWN IN 'ANCHOR SCHEDULE' THIS SHEET. S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE I O WALL FINISHES, INCLUDING BUT NOT LIMITED TO V STUCCO, FOAM, BRICK VENEER AND SIDING. 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN a ACCORDANCE WITH ANCHOR MANUFACTURER'S 0 INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BEMSED IN SUBSTRATES.WTTH STRENGTHS LESS E'1 too) THAN THE MINIMUM STRENGTH SPECIFIED IN THE IINCHORSCHEDULE'THISSHEET. - 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL p*d a O OR HAVE A CORROSION RESISTANT COATING. p v ry IL to w O A a ti w ANCHOR SCHEDULE. DOORFRAME. MANUFACTURER EMBEDMENT® ANCHOR CAPACITIES SUBSTRATE TYPE TYPE SIZE DISTANCE 13ASEDON SPECIFICATION(IN)w SHEET MIN. 3 METALISTEEL THREADS. TUBING 14 GA FIN (Z-BAR) PAN HEAD NO.8 ASNE B18.6.4 PAST INSIDE 318" MIN: 33 KSI YIELD MN. (TAPPING SCREW) SURFACE OF STRNEGTH THICKNESS SUBSTRATE ANSI B18.6.1 2XW00D (WOOD SCREW) : WOOD WITH AMINIMUM FRAMING FIN (Z-BAR) PAN HEAD NO.8 OR 1' 10 SPECIFIC GRAVITY OF ASME 818.6.4 0.42. (TAPPING SCREW) NOTES: 1) FOR WOOD OR TAPPING SCRI2WS IF SPUTim IS A CONCE;K MLL O.OS2' FILOT HDLE(DRLL SIZE45). 2) ®GE DISTANCEMEASURED FROM HTHER SIDEOF ANCHOR TO EDGEOF SUBSTRATE Robert J. Ammm, P.I FL P.E. No.49752 PRE oµO N6 :' ,m E Digitally signed by Robert J Amoruso Date: 2021.02.18 12:08:03 -05W 821/4' or *!E MAX OA MAX E FE DOOR HEIGHT PANEL HEIGHT 38 J' MAX, oA FRAME WIDTH 38' MAX. DOOR PANEL 8' MAX. WIDTH O.C. (TYP.). 4' MAX. (1YP� •--�{ � � 4' MAX. (T1'P.) B I J -4 3' MAX (TYP.) J F 4 X X LOCK ASSEMBLY IS LOCATED APPROX. 8' MA � 4 37' ABOVE BOTTOM OF DOOR LEAF O.C. (T 0 AND THE DEAD BOLT ASSEMBLY O —7 -4 APPROX. 41' ABOVE BOTTOM OF DOOR X LEAF. SEE STRIKE DETAILS THIS O SHEET. 74" ELEVATION EXTERIOR VIEW I. 1 #8 z 3/8' WOOD - SCREW I 1 1 ENTRY DOOR STRIREDEMEL WOonwnW suesMTK FOUR HALF HINGES, 7 AND 21' FROM EACH END OF THE DOOR PANELSECURED BY 08 X 3/4' SCREWS (TYPJ #STAPPING SCREW. SCREW MUST BE OF SUFFICIENT LENGTH TO I PENETRATE(3)THREADS I MINIMUM BEYOND STEEL 1 TUBE ENTRY DOOR STRM DETAIL 5mmTumosussmim 31� t SILL ANCHOR SPACING SAME AS HEAD SPACING ANCHOR LAYOUT EXTERIOR V83W ANCHORING NOTES: . 1. MINIMUM NUMBER OF ANCHORS IN JAMBS IS 14. ANCHOR SPACING VARIES, BUT NOT TO EXCEED e' MAXIMUM O.C. 2. MINIMUM NUMBER OF ANCHORS IN HEAD AND SILL IS S. ANCHOR SPACINd VARIES, Bur NOT TO EXCEED (' MAXIMUM O.C. Milluo RobwtJ. Amonm, P.E. FL P.E. No. 49762 Digitally signed by. t. Robert J s o� s • a•/f/W - Date: �P� 40p10;10?C wsoo��pgm 2021.02.18 12:08:47 05,00' 1° MIN. EMBEDMENT' WOOD SCREW ,- NSTALLATION ANCHOR d . 2X WOOD FRAME c i4 (BY OTHERS) 11Y MIN THREE (3) THREAD MIN. PENETRATION #8TAPPING SCREW o SEALANT TAPE TO BACK. EDGE DIST.: , _ m SIDE OF MOUNTING FIN INSTALLATION ANCHOR oa SEALANTTAPE TO BACK MOUNTING FIN SIDE OF 3fW MIN. EDGE DIST.. k' U4`MAX SHIM G EXTERIOR INTERIOR: 14 GA.. MIN. SQUARE . STEELTUBING(BY : OTHERS) U . o cma c� x _ o - - - - — - cli uj EXTERIOR : :INTERIOR :m viO a S XI ... .: :... DOC W G.1. 0�� cn B VERTICAL SECTION .c Q 0 SW a�� .a. .z m wooDFxAMB.sussTRnzB: D -:VERTICAL SECTION a'w Mwo �a >N STEELTUB GSUBSTRATE '. o Zro a Z_"g to O of o Q O'J �� W fitly Q W� EXTERIO INTERIOR . EXTERIOR 'INTERIOR 1/4° MAX,SHIM 14 GA, MIN. SQUARE STEEL TUBING (BY. OTHERS) . + .. RobertJ:AMcruso,P.E.' SEALANT TAPE, BACK C' FL P.E.No, 49762 SIDE OF MOUNTING FIN 1/2° MIN. ZX111lOODFRAME EDGE DIST. SEALANT TAPE TO BACK ';' 3/8' MIN.; EDGEDIST. .'• e"�o`-. N 6Y;P (BY OTHERS) y SIDE OF MOUNTING FIN #8 TAPPING.SCREVII `1QL Ly c c or tti kVWF I'MIN. EMBEDMENT —►I �{B WOOD.SCREW THREE (3) THREAD INSTALLATION ANCHOR ' INSTALLATION ANCHOR MIN. PENETRATION Digitally, slgried. by SECTION ' " Robert J Amoruso ' 0')_nRT1CAiL wooDnrw>E sussTRAze SEC VERTICAL TION . O Date: 2021.02:18' TUBING svasTR 1I 8:59.- YOO . . ...... ...... . 114' MAX SHIM 114° MAX SHIM O1 of Ie 112' MIN, EDGE DIST, 1/2' MIN. EDGE DIST: : . $ 2X WOOD FRAME 2XWOOD FRAME. a (BY OTHERS), (BY OTHERS) 8 #8 WOOD SCREW N8. WOOD SCREW �yB INSTALLATION ANCHOR INTERIOR INTERIOR' INSTALLATION ANCHOR X314"sms c1l 1•MIN.'o EMBEDMENT N J Y VMIN. w v EMBEDMENT �oN 3 F— SEALANTTAPETDBACK EXTERIOR EXTERIOR SEALANT TAPE TO BACK og o F SIDE OF MOUNTING FIN . SIDE OF.MOUNTING FIN. U�w V r N� m 0. D Iwo - a � Zi Z E . HORIZONTAL SECTION . F HORIZONTAL: SECTION WOOD FRAME SUBSTRATE p" �' p J WOOD FRAME SUBSTRATE Q o J�+� . ., z 0S. k. m �113 'Y • 14 GA.'MIN. SQUARE 14 GA. MIN. SQUARE 31W MIN, EDGE DIST STEEL TUBING (BY OTHERS) STEEL TUBING (BY OTHERS) 3/8' MIN. EDGE DIST. INTERIOR- INTERIOR N8 TAPPING SCREW: #8. TAPPING SCREW INSTALLATION ANCHOR tt8 X 3/4" SM$ . INSTALLATION ANCHOR THREE(3)THREAD THREE(3)THREAD MIN. PENETRATION MIN. PENETRATION 77\1 Robert J: Amaruso,:P.E: SEALANT TAPE TO BACK EXTERIOR EXTERIOR FL P.E. No. 48752 SIDE OF MOUNTING FIN SEALANT TAPE TO.SACK . SIDE OF MOUNTING FIN • + aaa ;6= YH� e H HORIZONTAL SECTION Digitally G HORIZONTAL SECTION srBBc ruBINOsuasTxArB . sighed by SUBSTRATE STEEL TUBINO Robert lAmoiuso= Date: 2021'.02.18 ' 12 05'00' :09:10 -