HomeMy WebLinkAboutRevisions; Building Plans1 2� 41 MATCH LINEB-B - LIGHTING GENERAL NOTES: SPH BASIS OF PAYMENT GENERAL NOTE: I A. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL UNLESS NOTED OTHERWISE, ALL ELECTRICAL DEPICTED ON THIS DRAWING RACEWAY WITH ALL OTHER UNDERGROUND UTILITIES. HLP-2a ARE INCLUDED IN THE PAY ITEM 13 34 00-1, "PRE-ENGINEERED METAL BUILDING LL T INCLUDING STRUCTURAL FOUNDATIONS (28,500 SF HANGAR WITH 3,000 SF B. LIGHTS ON EMERGENCY CIRCUIT TO BE BACKED BY UL , LEAN-TO OFFICE) - COMPLETE". 924 LISTED EMERGENCY LIGHTING INVERTER, REFER Ir1 ENGINEERS R PLANNERS 5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779 OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE CERTIFICATE OF AUTHORIZATION NUMBER: 5057 W WVAVCONINC..COM L 668 N. Orlando Avenue Suite l(V Mai8and4L 3275 407.897.6764 ph 407.894.1338fax .,rnlm-malXn.c YMC002208 MLM1115620 TREASURE COAST INTERNATIONAL AIRPORT STATE OF FLORIDA SEAL THIS REM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY THE INDIVIDUAL NAMED BELOW, USING A DATED DIGITAL SIGNATURE IN THE SPACE BELOW, PER FAG RULE 61G1S23.004. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ft ty8 Digitally signed by Sean Day DN: CN=Sean Day, OU=A01410C00000174BFE536470001014E at Date: INC., C=US. sun Date: 2027 03.05 08:55:47-05'00' `c4+ a°ioRaO� �Y SEAN DAY, PE STATE OF FLORIDA#80296 FPR MRO HANGAR LIGHTING SITE PLAN ATTENTION: THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARY INFORMATION, ALL OF WHICH IS EXPRESSLY. PROVIDED BY AVCON, INC., FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE. WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANY DISTRIBUTION, REPRODUCTION,: OR OTHER USE OF THIS DOCUMENT, IN WHOLE OR IN PART, IS STRICTLY PROHIBITED SCALE: REVISIONS: NO. DATE DESCRIPTION 6 12/18/2019 ESI #10 10 02/23/21 RFI #74 DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: DATE: 00 AVCON PROJECT NO K BEALLER K BEALLER S DAY S DAY MARCH 2O19 2017.259.01 1SHEET NUMBER ' 2 3 4 " ENGINEERS & PLANNERS 5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779 - OFFICE: (407) 599-1122 -FAX: (407) 599-1133 CORPORATE CERTIFICATE OF AUTHORIZATION NUMBER: 5057 VVAWLAVCONINC.COM C BUILDING MOUNTED CT UTILITY METER VERIFY 1 METER REQUIREMENTS - f — WITH UTILITY (FPUA) \ PANEL PANEL PANEL PANEL \O 'HP 'HL 'LP FPPU M I PANEL'MDP° C. ELEC. RM ELEC. RM EC. PANEL'LDP' EC. :ELEC. RM FIRE PUMP #114 #114 #114 BUILDINf2 600A MCB TX-1 600A MCB [ I PAD MOUNTED UTILITY 480Y/277V, 3P, 4W 225A MLO 100A MLO Q � 208Y/12OV, 3P, 4W 225A MLO 1 100A B TRANSFORMER SOOkVA 480Y/277V, 480Y/277V, � 208Y/120V, 20V, SECONDARY VOLTAGE 30, 4W 30, 4W ®-Y N 3111, 4W 3�, 4W 277/48OV, 3�, 4W D _j � S.P.D.7L S.P.D. G(JD BUS'TGB 668 N. Orlando Av.. S.R. 107 Maitland FL V75 ,107,697.6784 ph 407.894.1338 tax v .mlm- aa#in.c #AAC00220B MLMNIW20 I - -- G15-2 A DATED DIGITAL SIGNATURE IN THE SPACE BELOW, PER 3NED AND4. PRINTED COPIES OF THIS DOCUMENT ARE NOT 3NED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Digitally signed by Sean Day DN: CN=Sean Day, OU=A01410C00000174BFE535470001014EO DW AVCON INC., C=US Date: 2021.03.05 08:57:09-05'00' SEAN DAY, PE STATE OF FLORIDA #80296 0. Me-�1. ELECT L A-Y - RISERDIAGRAM GROUND LEVEL — --- BUILDING STEEL 2 sets of (3#350, 1#1G,, 3"C) 4#3/0, 1#6G, 2"C ATTENTION: - THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARY 2 Sets Of 3#350, 1#1 G, 3"C INFORMATION, ALL OF WHICH IS EXPRESSLY PROVED BY AVCON, INC., ( ) #4 COPPER GROUND WIRE FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE. WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, IN ' #2/0 BARE #2/0 BARE WHOLE OR IN PART, IS STRICTLY PROHIBITED COPPER GROUND COPPER GROUND SCALE: REVISIONS: CAD WELD UNUUNU ANU LIUH I NINLi. -- PROTECTION GROUND LOOP. ,I W COLD WATER SERVICE 2-- - — — PIPE (IF METAL) DESIGNED BY. A JUMPER OUND R 3/4" DIAMETER COPPER WATER LINE. ® DRAWN BY: COATED 30 FT. LONG STEEL GROUND ROD. 25 OHMS MAX. IMPEDANCE. TYPICAL FOR Z CHECKED BY: THREE MINIMUM. ®_ APPROVED BY: (� DATE: 1 ELECTRICAL RISER DIAGRAM----------- V = 19-0" � AVCON PROJECT N0. ' Z K BEALLER K BEALLER S DAY S DAY MARCH 2O19 2017,259.01 21 3 4 'mmm ROM PANEL: HLP SERVICE: 480Y/277V, 30, 4W AIC RATING: 35,000' FED FROM: PANEL MDP BUS RATING: 100A NEMA RATING: NEMA 1 - LOCATION: ELECTRICAL RM #114 MAIN TYPE: MLO (MAIN LUG ONLY) MOUNTING: SURFACE CONDUIT & CONDUCTOR SIZE BREAKER KVA KVABREAKER CONDUIT & CONDUCTOR SIZE LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION CONDUIT WIRE & GROUND TRIP POLE OA TDB (PC (PA O OC POLE TRIP' CONDUIT WIRE &GROUND 1 LTS-HANAGR ROW 1 3/4" 2#6, 1#10G 20A 1 3.20 2.40 1 - 20A 3/4" 2#8, 1#10G EPCr1 (EGRESS HANGAR LTS)- 2 3 LTS - HANAGR ROW 2 3/4" 2#6, 1#10G 20A 1 4.00 2.40 1 20A 3/4" 21; 1#10G EPC 2 (EGRESS HANGAR LTS) 4 5 LTS - HANAGR ROWS 3/4" - 2#6, 1#10G 20A 1 ,4.00 0.72 1 20A 3/4" 2#10, 1#10G EPC-3 (EGRESS EXT WALL LTS) 6 7 LTS'- HANAGR ROW 4A 3/4" 2#8, 1#10G 20A 1 2.40 0.37 1 20A 3/4" 2#10, 1#10G EPC-4 (EGl�, ESS EXT WALL LTS) 8 9 LTS - HANAGR ROW 48 3/4" 2#8, 1#10G 20A 1 2.40 0.Z* 3 1 20A 3/4" 2#12, 1#12G EMERGENCY LTS - OFFICE AREA 10 11 LTS'- HANAGR ROW'5 3/4" 2#6, 1#10G 20A 1 3.20 DAD 1 20A 3/4" 2#10, 1#10G EMERGENCY LTS - HANGAR AREA 12 13 LTS - OFFICE AREA 314" 2#12, 1#12G 20A 1 0.20 0.54 1 20A 3/4" 2#10, 1#10G LTS- WALL PACKS 14 15 LTS - RMS #114, #115, #116 3/4" 2#12, 1#12G 20A 1 0.17 0. 1 20A 3/4" , 2#10, 1#10G LTS - EXT WALL PACKS 16 17 LTS - RMS #111, #112, #113 3/4" 2#12,1#12G 20A - 1 0.15 0.91 1 20A 3/4" 2#10, 1#10G LTS - EXT APRON WALL PACKS 18 19 LTS - FP RM #10 314" 2#12 12G 20A 1 0- 0.40 1 20A 3/4" 2#10, 1#10G LTS _ EXT APRON FLOOD LTG 20 1 LI NG - # 3/ # 2, 1#1 A 1 35 0. 1 20A 3/4" 2#10, 1#10G LTS - EXT ROADWAY LTG 22 23 LTS - EXT ROADWAY "& FIRE BUILD 3/4" 2#10, 1#10G 20A 1 0.25 0.50 1 20A 3/4" 2#10, 1#10G LTS . EXT ROADWAY LTG 24 25 4.80 1 20A 3/4" 2#10, 1#10G CEPS - BACK-UP INVERTER 26 27 AHU-1 3/4" 2#12, 1#12G 30A 3 5.00 0.00 1 20A - SPARE 28 29 5.00 0.00 1 20A - SPARE 30 31 5.00 SPACE 32 33 CU-1 3/4" 2#12, 1#12G 20A 3 2.13 _ _ SPACE 34 35 2.13 - - SPACE 36 37 2.13 0.00 3 30A - 3#10, 1#10G SURGE SUPRESSION DEVICE 38 39 SPACE - - - 0.00 40 41 SPACE - - 0.00 42_ 13.33 14.05 1 14.73 8.51 3.71 2.23 PANEL SCHEDULE NOTES: FIRST 10kVA REC LOAD 0.00 RECEPT. DEMAND LOAD 0.00 **REFER TO EMERGENCY LIGHTING DIAGRAM ON SHEETS E105 AND E802 HVAC HEATING LOAD 15.00 125% OF LTG LOAD 37.71 KVA AMPS FOR EMERGENCY LIGHTING CIRCUIT DETAILS. HVAC COOLING LOAD' `6.39 ' 25% OF LARGEST MOTOR 0.00 TOTAL CONNECTED LOAD 56,56 68.03 EQUIPMENT LOAD 5.00 TOTAL DEMAND LOAD b1. 2 61.73 y4CLN$y. Digitally etl by Sean Day :. Se DN: 4N=N=Sean Day, O=AVCO1 INC., C0174BFE535470001014E, O=AVCON INC., C=US sax Date: 202103.0508:58:40A5'00' SEAN DAY, PE STATE OF FLORIDA #80296 PANEL: LDP SERVICE: 208Y/120V, 30, 4W AIC RATING: 65,060 FED FROM: PANEL NAME BUS RATING: 800A NEMA RATING: NEMA 1 _ LOCATION: ELECTRICAL RM #114 MAIN TYPE: 800A MCB MOUNTING: SURFACE CONDUIT & CONDUCTOR SIZE BREAKER KVA A BREAKER CONDUIT & CONDUCTOR SIZE LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION CONDUIT WIRE & GROUND TRIP POLE OA 0B @C OA B OC POLE TRIP CONDUIT WIRE & GROUND -- 8.70 23.14 1 REC - SREC80-1 MODEL # 1-1/2" 4#1, 1#8G 100A 3 3 200A 2" 4#3/0, 1#6G LPP 2 8.70 14.34 8.70 16.55 8.70 9.74 3 REC - SREC80-2 MODEL # 1-1/2" 4#1, 1#8G 100A 3 3 125A 2" 4#2/0, 1#4G FPLPP 4 8.70 7.23 8.70 8.02 8.70 3.00 5 REC - SREC80-3 MODEL # 1-1/2" ' 4#1' 1#6G 100A 3 2 40A 3/4" 2#8, 1#10G ELECTRIC WATER HEATER EWH-2 6 B8.7 8.70 -3.00 8.70 _ _ _ SPACE 7 REC - SREC80-4 MODEL # 1-1/2" 4#1, 1#6G 100A 3 8 I- - - - SPACE 8.70 - ------- SPACE - - - - SPACE - - _ _ _ _ _ _ _ _ SPACE 9 SPACE - - 1,50 2 30A 3/4" 2#10, 1#10G AHU-2 / CU-2 MINI SPLIT 10 SPACE - 1.50 11 ELECTRIC WATER HEATER EWH-1 314" 2#10, 1#10G 30A 2 1.50 - - - - - SPACE 12 1.50 SPACE - - - - - - 0.00 13 SPACE 3 30A y 3#10, 1#10G SURGE SUPRESSION DEVICE 14 >< 0.00 0.00 I P0729.07 3 800A MAIN CIRCUIT BREAKER 36.30 36.30 34.$0 35.88 FIRST 10kVA REC LOAD 0.00 RECEPT. DEMAND LOAD _ 0.00 HVAC HEATING LOAD 0.00 125% OF LTG LOAD 0.00 A AMPS HVAC COOLING LOAD 3.00 25% OF LARGEST MOTOR 0.00 TOTAL CONNECTED LOAD 196.42 542.46 EQUIPMENT LOAD 140.22 TOTAL DEMAND LOAD 143.22 397.56 a FPR MRO HANGAR ELECTRICAL PANEL CE ULES ATTENTION: THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARY : INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON, INC., FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE. WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANY .DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, IN : WHOLE OR IN PART, IS STRICTLY PROHIBITED SCALE: REVISIONS. NO. DATE DESCRIPTION ; 9 - 01/08/21 RFI 71 10 02/23/21 RFI #74 ` W D DESIGNED BY: K BEALLER c) ® DRAWN BY: K BEALLER z CHECKED BY: S DAY O APPROVED BY: S DAY 0 DATE: MARCH 2O19 - AVCON PROJECT NO. 2017.259.01 On z ® SHEEN NUMBER rasassa. - 1 2 f PANEL: LPP SERVICE: 20$Y/� 2OV,, FED FROM: PANEL LDP BUS RATING: 225A — LOCATION: ELECTRICAL RM #114 MAIN TYPE: MLO (MAIN LUG 0o, 4W AIC RATING; 22,000 NEMA RATING: NEMA 1 ONLY} MOUNTING'. SURFACE CONDUIT & CONDUCTOR SIZE BREAKER KVA ` KVA BREAKER CONDUIT &`CONDUCTOR SIZE LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION CONDUIT WIRE & GROUND TRIP POLE NA NB 4>C IVA Gi$ OC POLE TRIP CONDUIT WIRE & GROUND 1 REC - SREC60-1 MODEL # 1" 3#4, 1#10G 60A 2 3.91 3.91 2 60A" 1" 3#4, 1#10G REC-:SREC60-2 MODEL# 2 g 3.91 3.91 4 5 `REC - SREC60-3 1 3#4, 1#10G 60A 2 3.91 3.91 2' 60A 1„ 3#4, 1#10G REC - SREC60 4 MODEL # 6 8 9 CORD REEL #1 POWER C 3 14 2#10 1#10G ' 0 2 A 1 0.36 0.09 2 30A 3/4" 3#$ 1#10G - - REC OF RACK TWIST LOCK C O K OUTLET 10 11 _ POWER CORD REEL #2 3/4" 2#10, 1#10G 20A 1 0.36 0.0,9 12 13 POWER CORD REEL #3 3/4 2#10,:1#10G 40A 1 0.36 1.18 1' 2 OA 3/4 2# 0 1#10G 1 EXHAUST FAN EF 1 E U 14 15 POWER CORD REEL #4 3/4" 2#10, 1#10G 20A 1 0.36„ 0.36 1 20A 314" 2#10, 1#10G EXHAUST FAN EF-2 16 17 _ REC .OFFICE AREA RM #110 3/4 2#10, 1# 10G 2 OA 1 0.72 0 ,70 1 30A 11 < 3/4 2#10 ' 1#10G , EXHAUST FAN EF-7 18 19 REC - OFFICE AREA RM #110 3/4" 2#10, 1#10G 20A 1 0.54 0.36 1 s 20A 3/4" 2#10,1#10G REC - IDF RACK QUAD 20 21 REC RMS #111, #112, #113 4n 31, 2#10,1#10G 20A -1 0.54 0.72 1, 20A` 3/4" 2#10 1#10G REC - IDF BACKER BOARD QUAD 22 23 REC - FPER RM #101 3/4" 2#10, 1#10G 20A 1 0.72 0.54 A' 20A4 3/4" 2#10, 1#10G REC - HANGAR CONVENIENCE 24 25 REC - RM#115, #116 3/4" 2#10, 1#10G 120A 1 0.90 0.72: 1 20A 3/4" 2#10, 1#10G REC -E:XT WP GFCI OUTLETS 26 27 REC - RM #114 314" 2#10, 1#10G 20A 1 >< 0.54 0.54 1 20A` 3/4" 2#10, 1#10G REC - EXT WP GFCI OUTLETS 28 29 REC -RM#103 #107 3/4" 2#10, 1#10G 20A 1 >< 0.72 054 1 20A 3/4" 2#10,1#10G REC - EXT WPGFCIOUTLETS 30 31 REC - RM #105, #108 3/4" 2#10, 1#10G 20A 1 0.72 0.10 1 20A 3/4.1 2#10, 1#10G MD1, MD2 MOTORIZED DAMPERS 32 33 `REC - OFFICE 3 4" ( 2#10 1#10G 20A 1 1.08'' 0.10 1'- 20A 3/4" 2#10, 1#10G , MD3 MD4 MOTORIZED DAMPERS 34 35 REC - OFFICE AREA JBOX 3/4" 2#10,'1#10G 20A 1 1.08 0.20 1' 20A 3/411 2#10, 1#10G DMP CONTROL PANEL 36 37 REC - OFFICE AREA JBOX 3/411 2#10, 1#10G 20A 1 1.08 '>< 1.18; 1. 20A 3/4" 2#10, 1#10G SUMP PUMP 38 33 :REC -OFFICE AREA JBOX 3/4" 2#10, 1#10G 20A 1 1.08' 0.25 1° 20A 3/4„ 2#10, 1#10G -PHOTO CELL - EXT LIGHTING 40 41 REC - OFFICE AREA JBOX 314" 2#10, 1#10G 20A 1 1.08 ' 1.98 1 20A 3/4" "2#10 1#10G *FUTURE AIR COMPRESSOR DRYER 42 43 EWC-1 OFFICE WATER COOLER 3/4" 2#12, 1#12G 20A 1 0.36 - - - SPACE 44 45 SPARE - 20A 1 0.00 SPACE 46 47 SPARE - - 20A 1 0.00 - SPACE 48 49 SPACE _ _ - - SPACE 50 51 SPACE - SPACE 52 53 SPACE _' _ _' SPACE 54 55 SPACE - -' 0.00 3 30A ( 3#10, 1#10G ,, SURGE SUPRESSION DEVICE 56 57 FACP - 2010, 1#10G 20A 1 0.50 ' 0.00 58 59 ISPACE - _ 0.00 60 11.78 ;1 8.37' 1 8.59 11.36 5.97 7.9,6 -- FIRST 10kVA REC LOAD 10.00 RECEPT, DEMAND LOAD 3.02 PANEL SCHEDULE NOTES: HVAC HEATING LOAD 0.00 125% OF LTG LOAD 0.00 < KVA AMPS " FUTURE CONNECTION, WIRE SIZE IS BASED ON BREAKER SIZE NEEDED " FOR EQUIPMENT. BEFORE INSTALLATION VERIFY LOAD AND BREAKER HVAC COOLING LOAD 0.00 25/o OF LARGEST MOTOR 0.30 TOTAL CONNECTED LOAD 54.03 149.98 SIZE PER NEC. EQUIPMENT LOAD 21.17 TOTAL DEMAND LOAD 34.49 95.72 PANEL: FPLPP SERVICE: 208Y/120V, 30, 4111 : AIC RATING: 22,0,0o FED FROM: PANEL NAME BUS RATING: 22 Tom" NEMA RATING: NEMA 1 LOCATION: FIRE PUMP BUILDING MAIN TYPE: 100A MCB MOUNTING: SURFACE CONDUIT & CONDUCTOR SIZE BREAKER KVA A BREAKER CONDUIT & CONDUCTOR SIZE LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION CONDUIT WIRE & GROUND TRIP POLE NA OB oC Ii 4)B OC POLE TRIP CONDUIT WIRE & GROUND 1 JOCKEY PUMP CONTROLLER 3/4" 3#10, 1#10G 20A 3 3.05 1.50 1 20A 3/4" 2#10, 1#10G` BLOCK HEATER PUMP #1 2 3 3.05 1.50 1 20A 3/4" 2#10, 1#10G BLOCK HEATER PUMP #2 4 5 3.05 1.20 1 20A 3/4" 2#10, 1#10G' FIRE PUMP CONTROLLER#1 6 7 EXHAUST FAN EF-8 3/4" 3#10, 1#10G 20A 3 1.27 1.20 1 20A 3/4" 2#10, 1#10G FIRE PUMP CONTROLLER #2 8 9 1.27 1.00 : 1 20A 3/4" 2#10, 1#10G HEAT TRACE, BACK FLOW 10 11 1.27 1.00 1 20A 3/4" 2#10, 1#10G HEAT TRACE, FILL VALVE 12 13 _ E REC INDOOR CONVENIENCE „ 3/4 ;2#10 1#10G , 20A 1 L083� 0.20 1 20A 11 3/4 2#10 1#10G' TANK LEVEL CONTROLLER <: 14 1 TIME C K /4e 2#1 0 OG 20A 01 . 8 2 3 1 20A 3/4 2#10 1#10G , TANK FILLBUTTERFLY VALVE 16 17 L-INTERI R 3/ #12, 1#1 2 A 1 0.30 1.20 1 20A 3/4" 2#10,1#10G AUTOMATIC FUEL PORT 18 19 - LTS EXTERIOR 11 3/4 2#12, 1#12G 20A '->, 1 0.72 1. 44 1 20A ,1 3/4 2#10 4#10G DMP-5 DMP 8 MOTOR DAMPERS M O A 20 2 RE - '- Oc00 00 1 20A - - SPARE 22 23 SPARE - - 20A 1 0.00 0.00 1 20A - - SPARE 24 25 SPACE _ - _ _ _ _ SPACE 26 27 'SPACE - - - - - SPACE 28 29 SPACE - - - - - - SPACE 30 31 SPACE _ _ - - - - SPACE 32 3 PACE - - SPACE 34 35 S ACE - - - ' 1 SPACE 36 37 MAIN CIRCUIT BREAKER _ 100A 0.00 3 30A 3#10, 1#10G SURGE SUPRESSION DEVICE 38 39 - - - 0.00 >< 40 41 _ _><0.00 42 6.12 4.50 4.62 4.34 .73 3.40 — FIRST 10kVA REC LOAD 1.08 - RECEPT. DEMAND LOAD - 0.00 HVAC HEATING LOAD 0.00 125% OF LTG LOAD 1,28 KVA AMPS HVAC COOLING LOAD 0.00 25% OF LARGEST MOTOR 2.29 TOTAL CONNECTED LOAD 25.71 71.37 EQUIPMENT LOAD 23.61 TOTAL DEMAND LOAD 28.26 78.43 ;3 4 Fitit r h Rim ENGINEERS & PLANNERS 5555 E. MICHIGAN ST., SUITE 200 - ORLANDO FL 32822-2779 OFFICE: (407) 599-1122 - FAX: (407) 599-1133 CORPORATE CERTIFICATE OF AUTHORIZATION NUMBER: 5057 .. ' NMM1NAVCONINC.COM S. BBB N. Orlando Avenue n i�. Meitlantl FL 32]6 407.897.6764 ph 407.894.1338 fan ..mUn-mmUn.can #AAC002208 MLM#t8820 _ , , c x s z MLM MA nrctrtx'uCxB:axc: TREASURE COAST INTERNATIONAL AIRPORT STATE OF FLORIDA SEAL THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY THE INDIVIDUAL _ NAMED BELOW, USING A DATED DIGITAL SIGNATURE IN THE SPACE BELOW, PER FAC RULE 61G16-23.004. PRINTED COPIES OF THIS DOCUMENT ARE NOT .CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. g�yrlOE#9,�N - r , Scale Digitally signed by Sean Day DNl CN=Sean Day, - b OU=A01410C00000174BFE535470001014E, a a. O=AVCON INC., C=US E Date . 2021.03.0506.5617-0500 da1B � OVAL SEAN DAY, PE .. - OTLTG /lC CI lllllllll .LLOI,Ol1C ELE®TmRICAL PANEL L® ATTENTION: THIS DOCUMENT CONTAINS PRIVILEGED AND PROPRIETARY I Y INFORMAT 0 I N ALL OF WHICH IS EXPRESSLY PROVIDED BY AVCON NC. FOR USE BY THE INTENDED RECIPIENT, AND FOR A SPECIFIC PURPOSE. WITHOUT THE EXPRESS WRITTEN CONSENT OF AVCON, INC. ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT, IN WHOLE OR IN PART,IS STRICTLY PROHIBITED SCALE: REVISIONS: ' NO. DATE -- SC DE RIPTION 10 ;02/23/21 RFI # 74 LO w D DESIGNED BY: K BEALLER U ® DRAWN BY: K BEALLER ® CHECKED BY: S DAY ®_ APPROVED BY: S DAY O DATE: MARCH 2O19 AVCON PROJECT NO. 2017.259.01 Z ® SHEET INUMBER E a� jT03