Loading...
HomeMy WebLinkAboutRevisions; Original Signed & Sealed Truss packageOFFICE USE ONLY: DATE FILED: _ REVISION FEE: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 9201 Potomac Dr Creekside Plat # 4, Lot 65— Permit # 2002-0052 DETAILED DESCRIPTION OF PROJECT REVISIONS: Original signed and sealed Truss package for change of Truss company. Permits were from 2017 building code, attached documents reflect 2017 building code i CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1327068 BUSINESS NAME: D R Horton Inc QUALIFIERS NAME: Brian w Davidson ADDRESS: 1430 Culver Dr NE, CITY: Palm Bay STATE: FL PHONE (DAYTIME): 321-953-3162 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 STATE: ST. LUCIE CO CERT. #: r ram: FAX: ZIP: 32907 ZIP: ZIP: tit Planning & Development Services Building & Code Regulation Division 2300 Vlrginla Avenue Fort Pierce, FL 34982 REVIEW COMMENTS PROPERTY INFORMATION Address: 9201 Potomac Owner(s): D R Horton Inc City / State / Zip: Fort Pierce, FI 34945 Parcel M 2327-502-0073-000/3 Jurisdiction: SAINT LUCIE COUNTY Zoning: Lot#: 65 Block: APPLICATION INFORMATION Permit Number: 2002-0052 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Brian W Davidson Business Name: D R Horton Inc Business Addr: 1430 Culver Dr Ne City / State / Zip: Palm Bay, FI 32907 REVIEWS AND COMMENTS Review Type Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lori Bender Comment: DOCUMENTS MISSING APPROVED Karen Nielsen Comment: ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen Comment: PE REVIEW COMMENTS (2) COMPLETE William Durden Comment: PE REVIEW COMMENTS (3) COMPLETE William Durden Comment: PLANS EXAMINER REVIEW COMPLETE Joseph Fersch Comment: REVISIONS INCOMPLETE William Durden 3/9/2021 Comment: CHANGE TO TRUSS MANUFACTURES. Automatic Sprinkler System? No Fax Number: Email: Mel bournepermitting@Drhor ton.Com; Bssmith@Drhorton.Com Date Started Date Completed Date Released 2/11/2020 2/11/2020 2/4/2020 12/14/2020 12/14/2020 2/11/2020 2/11/2020 2/11/2020 2/4/2020 2/4/2020 2/4/2020 5/15/2020 5/21/2020 5/21/2020 5/21/2020 11 /19/2020 11 /19/2020 2/20/2020 5/15/2020 5M5/2020 3/9/2021 FILE COPY a r� %' Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34992 REVIEW COMMENTS 3/9/2021 Comment: ENGINEERING PACKAGE DATED SEALS ARE NOT CURRENT. PLEASE SUBMIT CURRENT DATED DOCUMENTS. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: ENGINEERING PACKAGE CODE / MISC CRITERIA IS INCORRECT. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. Comment: SUBMITTED DOCUMENTS ARE COPIES. DOCUMENTS THAT REQUIRE A SEAL AND SIGNATURE MUST BE 3/9/2021 SUMMITTED IN ITS ORIGINAL FORM WITH ORIGINAL SIGNATURES. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: MANUFACTURERS TRUSS DRAWINGS DESIGNER DATE NEEDS TO BE UPDATED. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: MANUFACTURERS TRUSS DRAWINGS DESIGN CRITERIA IS INCORRECT. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. ZONING REVIEW COMPLETE Angela Vassar 2/11/2020 3/9/2020 3/9/2020 Comment: 30'-8' 0 O I IG Labeled End Mark Total Truss Quantity = 89 DIMENSIONS FOR BAY WINDOW JACKS. THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. EFER P'F� SHINGLE ROOF CXlfDUEcnow 5 _ HEEL•/-1/1 ' __--CIO PLUMB CU 1'- (SEE STRtINGBACK LETTER -0• IN ENM PAD]O P-C. Y SETBACK CORNERSET LABELING AND SPACING FILE C®P*f . General Notes 1) N palaltl daN 4us3m Not ham aad not .Wpd-d pxb* P-hd grM to be iutnxed {'eai aide u¢ 2) notes.A I qn to be Smp3m HA26 ud , o0wWm 3) M bun 3Pocim is 24' O t unlen cale�ce note& 4) Per T. Ptafe 1m10ute M%-81 raoomlydatim pmnmed Xilooig slob be pkmd at a Indo. 3porig 15' = aeon the Re'. to be npeoted at a mmianrn of 2D' bdaem ead' x�lare N3a1¢nut the eb'Iobe. None Ides b BOS % for ay oddiflmd bro*V ROOF LOADING SCHEDULE TCLL = 20 PSF BCLL ee = 0 PSF BCDL 10 PSF 37 DURATION = 1.25 R WIND SPD/TYPF 160 ENCLOSED BLDG EXPOSURE = C USAGE= RESIDENTIAL CAT H WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 pSF DESIGN CRITERIA FBC 2020 TPI 2014 Trms member dm& & conn=orpbks aredeSmr�r.d forAs 7-IS andnadmno fo¢esfrombothcompoments, amdctaddimg amd mudnnind force tesstmg systems • These tenses have be®revicnvd to carry m additio®1101/ps'>ma-cook mlwmamchonl live FLOOR LOADING SCHEDUL TCLL = PSF TCDL = PSF BCDL = PSF TOTAL PSF ROOF DESIGNED FOR _.. _._SHINGLE ALL REACTIONS AND UPLUM ARE SHOWN ON ENGINEERING WALL KEY ® 0 l� LOAD# DESCPoPDON INIr. DATE 3d QUO ]11RVID V3e1 M aun ■n M1nU rM1OliarR HIW M 1/D/D 31II Ie.Y � ® M ll/rL0 t 1 1 00, CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE 6 N. V. WINTER HAVEN FLORIDA 33880 PHONE' (BOW 959-8806 FAX' C863) 294-2488 BUILDER D.ILHORTON/BREVARD PROJECT CREEESIDE MODEL 1756/EASTHAM/EXPRESS CCA PROJ/MODEL/ALT 7A5/320 175RA ALT DESC OTC LOT 65 BLOCK DESIGNER RWM PAGE DATE 01.14.2014 'k372962L 1 4 "=1' c e I CIS Builder: Project: Model/Building: Lot Alt: ENGINEERING PACKAGE D.R.HORTON / BREVARD L7A5 (R EKSIDE 175 EA Lot: �6 5 Address: ................................................................................................................................... JobNumber:N3729 ...... .............. .62............................................ _............ ......... ..__ Block: Unit: Revision Date: New Load #: CARPENTER CONTRACTORS OF AMERICA, INC 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 RG01 �L.P.11 VE Wirch 1-3,20.19 AN, [TWC&IPAW M.r.e�. Bob:Bob:Mi6haelis C-arO&ht6(Cdhtraict6ts of. Am6ridk Inc:. Avenue G... Northwest Winter Haven, FL 33.680-6261' Re: AlternatiV lh�tdlWions-.for a single ply carried truss with a width Jess t . han . . ..:i . the hanger width, and wood. blocking .to: achieve fUll design load:Value.-fdr face mounted: on -a oh'�i'ply . . design load . . hanger supporting girder (Reference M611 WA3M2).-. Dear Bob, For . a . single 'ply carried truss with a width less than the'hanger. width -yodcan ih;gqll ;P. prefabricated jack scab .truss: Mfor wqod.filler b16ckih.g;.- The chord: sites,;.chor.d.grqOes, to. be the. m same as the sihg1e:ply caed truss. he prefabricated .jO'ck:!§dEib'trLiss(*'Y,.ill h6v'6 -a.minimuM length of 481' and will have a minimum.pit6h.:qf-,51-12,, The single ply carriedir, ss:shall have ` " . ... 1.­­, , , " ­ , * , , ' , , " , 4­ ... U , . :a reaction of 3,;500# or less. Attach prefabricated, with: two. (2) toft of 0.128"x3.0" GUn Nails at,2' O.C. pery6w,-stagger6d 1"..(See FigUe6 I b6l6w). P]6ase,fef&tb.thb. Simpson Strong.Tie Catalog C-C 201:9. page 216FigpreSfor more information; figure -I For-p sing*Jepl'y­' iMe"rAhat requires Wood blocking to,tidhie'vefUll design load value forfaPe-mounted hangers -attach one wood. block M to'the back fac.e. of the singje::p y girder With the: samesize: an d drade--as'the' bottom.- chord 6. d, fthe. single 01y girder. T W. block length be such that'Ahe'wood .b . lockinig-extends to each adja adjacent; panel points ;(Webt.Afid b6ttom(ch6rd intersections): Attach wood. blocRi(�)-with -two: -(2) rows. -of 6 -1 281n, X.3.0,i 0.6n N6ils at.0!.0,10, per row,. 3.0"'applied to the 676o'F'orum Drive Suite 305,Qdaindlq .442279685 FL 3M. mwmalpineitm,com " ALPINE -page 216' ' =,—_.. *,for ._--. in'-- '--i_. ! ' r�Kw/�Z` _ --... ..... ..... ~... ... -___--_--___-'�_�=-�-- The ---_mf,---_-'_���c�b���mf�rWood —__-_`orwood blockin bq`'fd_U = -'--'-- - design koad'vmkJeforh6ngqrs Must by the. - All `edo�.andeind: distances, mbd for ' all naU 'nnust.bm. to of \mood- Ifican.be. ofany further ifyop'hove anyqDlease7glve mpocal ]^� Orlando, FL STATE diz \./ 875O'Fbh]h1Ohv� ;OWabd6`pL32821-(80%'52178790-(863)422-8685 ��.a�n�b�¢ m 61 ALPINE 1%1TWCW~ April 26;:2019- Mr. Bob Mich afe'lis Carpehter'Contractors of America, Inc. Avenue O: NoOWqst -Winter Hav6n, FL 33880-6201* Dear, Bob,. .Rb- Stronobabk brid.ghig on fb6f.trusset. I understand -there is some concern over our recommendationsfor strdhgba . c'k bridging on. roof trusses, 'Stron bat bridging irernentofthe g. ... k . ..ging-for roof trusses is not.a requirementof:ANSJ-�TPI 2014 nor it re U.. q BuildingComponent -Safety Information (BQS.Jji'. s't­r*.o'rigback bridging on roof trusses is recommended " by Carpenter Contractors of. !Ameri6a:_-Str6dgba*ck bridging -se'r'v'e­s­_1h.q:. folIpwilig two. me - Cl f6rictio'n.s; - One, bridging aligns the bottom chords after -they: are- set ,so.. they .are uniform. along the, ceiling. fine # andhOlo§'with teilihg,�sorvicOa T-Woj bridging reduces t6lativ& d6flection.of. adjacent trusses:: Strongbackbridg'ing''-doe's iiot..-OrLiVent-jorr6ducig�-ovet.zilI in'diVidual d6fiectidn, especially an-y" to6fteu§�96s. f 10 rn rq. an 1W inch. lqq�_g p� - ­ L-J.- inch: —.-- __ .. .... ..... .. ......... .. ....... ....... Sirongoack- bridging in roof. trusses doe's not serve. as femobrary.. or permanent bracing .and is not Ai§tribut6 otshate, design loads, bef�veeh trusses. Qqnsequently, intended to no design load' been , n accounted for With this. detail and continuous- strdhgback'bHdgihd thbUld riot bb ..att6cihed between common and g'irder trusses-. The. use :of strortgbac bid hall not1riterfere with other, design . trusses-. . ... .. .. K bridging` s ..g considerations as sp�ec1fie-d::by the Ehgfi!06J­'ci.f Record or the. Buildling,Designer_ The outer ends ofthe sirori.'g'backbridging .shall beaft9ched.-to awall-or another%secure end..pesirainf,"o "or ap..sppciried:.py the Engineer of Rkord or.thd Bu'ildin4..D6sJ6d&r-.- Str6figb6ck- bridging shall be fa. minimum of 2X6 bomihbf I+urrib6r. oriented -with 'the depth vOtticaf: Attach with -8) f6d :common. nails (0.16Z�x&-5."-) nails at:. each intersecting 'rhembei�. When -extending the Wi Copm v...: .stron back bridging overlap by -At'a. .minimum of two trusses. Thelocatipq of. the: strong6ack.- bridging,. - maybe: specified :by "the -Truss MahUJf6dvt6r-,. Engirie&rdf*Record,. or Building Designer: _1`516asd refdelto- bC;,-S,l "'StrangbaWng PTovis:ions' Dr'to...A.1pine,, 8TKOFOOPI.04 detail for more information. The graphi& showh'(FidUre-A) is� for g.en.6r!d'iflustrdtiv.e'p.drobse only. ,67.50 F.brurn Drive:S . uite 305, Qrl6ndo, FL 32821z. - (800).521-07K.- (863) 422-8685 Figured. If I: can be of any fudher assistance' orifyou ,have :-any questions -please: give. me a call. Willia-Mi . H..,Knck. KE'. Phief'.E,ng'q)per - Alpirle an I . tW:.Company Engineering 'Department -Oelan.clol,. FL 32821. 678.0. - Forum Drive Sulte,396, Orlando; FL 32821, (800). 52T-9.790 - (8153).422-8685 WWWAI, * " M. ppet .,..cQm STRO NGBAtk :FI IDGING RECDMMENDATIDNS MUTT STRONGBACKOGETHER op All scab7-� on blocks -shaLl, be�--m- minimum. 24x4- 'stress , 1RIDG- ING T graded -Lumber;' o..-All .-stnongback bridging and bracing shall mInliqum 8x,0 '.Stress- ►.Th -pose of s�rondb,ar,k �brld6lho -is. 10 e put ATTACH SCAB WITH'10d:Bm�GUN H ..' develop sharing etwegn-Indkild �us-ses-,.. W -0.' bib. 6. NA LS, 3W;g ROWS --.AT ♦SCAB D.C. In dn .Increase' N13TEI LIEU. OF SPLICING, AS" SHOWN, LAP"STRUNGBACK-1RIDGING MEMBERS- stifpnessr.:of the. floor. systeft -2k6* stf-ongback . bridgino'i In FDR:AT LEAST ONE TRU=:SPACIN STRIINGBACK� 'BRIDGING: SPLICE DETAIL details, Is recommended .at 10' =01*.O.c. (Ma><> --The- terms: 'bridbind' and 'bracing` sometimes ebl6ttoithmeht Mo-thbd, .ND.TEi Details J. and 2.-arli? . .t:h'e ';priefC'OerH'r' ATTACH ATTACH 'I ONGBACK TO N .�aresom mistakenly used: Interchangeably.' ''Bracing'' isandauI ')10d ILS'DN NAOR structural teoulre4ent- bf any Plbb,:(0X4a'x3 ..(01W BMIGUN -) 28k3,0'),. NAILS or roof -:system, !Refo- to- the,: Truss. Design ( D - -brgwlng MD) for the;bratlnb ".,quV6 'for mients each IndiVicluoLk truss component. 'Brldglng;4' 1 ar p ticutaHy, 'strongback.`;brIdg!ng1 :Is "a': rec:6 -t , mmehdatlon- fo - r *6 truss ss- s�ystL��M to. help Mob: control V16r�tlara'), In: add' -to :aidlrig :In the: distrIbytion of point' loads JoetW66­6 adjacent -truss, reduce strongbac o; k brIdgIng, serves� -t m WW4 13723 Vvii;kh fte S019 MO ma6law valghts. Mc STRONGBACK BRIDGING ATYANME'N'T ALTERNATIVES W Web bounce. or reslap. . vibration: o,.s� q. r.e u ho, from Moving po.n.. Ibqdi�.j :such as footsteps: T15e performance of all 'floor :systems -are. enhanced' by. the. frittallat(oh of :s.tro:hgb.atk- brIcIgInd and therefore :Is. strongly recommended by -Alptne, For additional Info i ' Imatl6h r*egardItig strongbQ,c* bi.-Idglng,. referto' 13CSI*(BUILdIng component Safety. Information). No. �0861 _(V m PSF EF REF T & DL. PSF DATE QCIDL PS.F- 11RWC rc. I'LL.. PSF D. PSF SIA:FAC,. F111' iF'.0-'L ,ZTS ,�F _C-1-).N.$ F'lVd :l N •4A:TEM-AL WFE-IJO INN, MORE -THA,� a�G ,I{r��' V �� ?�.AOf �U• ON' F-400R. �`nWS' ' R. U -D . C � NTRATEq E.0 Q�1 ' TC [QE''.PA ' Cl�'�t1rv. dtJ%.e. SIM • PPRGPRTA.: R' X. rirr QA:.1�[9Fit� .A. L t#:5 AND.: tri{'c#.irr..P'31r . '_l' rf 1i�[ '. ,. °Nod' :.. Sk r.i.t 1AL b:PM t:hBt�R: — ..: -- , -- !• ��1.�. US7•ALL Al b _TID. �C?MM, C ?!{i,• 7 NHS 11 Fa -},, 33 tint i dp ..Ns "l i>7 ►r ul 1JO. BE', SitPLi�(S: �S3tr11 #ter• :� 411 Zny_' ' F1 � 1 1'OA.. k�Y . gum . ..:.,. .: ;. Y.:. ., -.y;uiK='•iYw,•u.+...--r:.s�.v.n m:.7"r-,. - • ... : •:��j—.P �,TV�hs1 1 i;.�gi+r �%Y%!1•9• ... ' . `?d L!" !,dry• #�,1wq����l` , i'Oi.`' " i r . kt• l., '.:' � ! IS 1 > t4«1': �{:•1im:5� .. 'i , f CLE -04 ..:' �I .tom ram• Ca• d,�1' :. CG • t 1= :. --a '. .: i1'. t� .y CrJ, ate, ...7" }. s •.5 ,rr orood. rf� :UAW f'!tlL� 960 ; Cracked or Broken This drawing specifies repairs for a truss with broken chord or web member. This design Is valid onlyy for single ply trusses with 2x4 or 2x6 broken members, No More than one break per chord panel and no More than two breaks per truss are allowed, Contact the truss manufacturer for any repairs that do not comply with this detail, (B) = Damaged area, 12' max length of damaged section (L) = Minimum nalling distance on each side of damaged area (B) (S) = Two 2x4 or two 2x6 side members, same size, grade, and species as damaged member. Applyy one scab per face, Minimum side member lengths) _ (2) 1-) + (B) Scab member length (S) must be within the broken panel, i Nall Into 2x4 Members using two (2) rows at 4' o.c,, rows staggered Nall Into 2x6 members using three (3) rows at 4' o,c„ rows- sttaggered, Noll using 10d box or gun halls (0,1281x3', min) Into each side member', The maximum permitted lumber grade for -use with this detail Is limited to Visual grade #1 and MSR grade 1650f. This repair detail may be used for broken connector plate at mid -panel splices. This repair de -tall mar not be used for damaged chord or web sections occurring within the connector plats; area. Broken chord may not support any tle-In loads, Member: Repair Detail Load Duration = 0Y. Member forces may be Increased for Duration of Load Maximum Member Axial Force . Memberi Size L SPF-C HF DF-L SYP Web Only ' 2x4 12' 620# 635# 730# 8004 Web Only ' 2x4 18' 975# 1055# 1295# 1415# Web or Chord 2x4 24 975# 1055# 1 1495# 1745# Web or Chord 2x6 1465# 1585# 2245# 2620# Web or Chord 2x4 30 1910# 19600 2315# 2555# Web or Chord 2x6 2230# 2365# 3125# 3575# Web or Chord 2x4 36' 1 2470# 2530# 2930# 3210# Web or Chord 2x6 3535# 3635# 4295# 4745# Web or Chord 2x4 42 2975# 3045# 35054 3835# Web or Chord 2x6 43950 4500# 5225# 5725# Web or Chord 2x4 3460# 3540# 4070# 4445# Web or Chord 2x6 5165# 5280# 6095# 6660# S• Mlnhun L 1"anae a L i L ---ITyplc t s L + o + o + o' + 0 L o + 0--+ - - o + o + jihlnLin L �Dlstanca Ss t gger L Back Face 1MM0d Box (0.128'b x 3', min) Nails, o = Front Face 2x6 Member - Trl lee Row Staggered ered MJNnun ad Nafl Spacing Detail L Dictonee B L rsVWaNMNN READ AND FOLLUV ALL NaTEs ON nil$ MVINa1 REF MEMBER REPAIR WWMTANTww rMSH TlIS DRAVM TU ALL CCNTRACTDRS IMLUDINa THE INSTALLERS, Trusses require wNtrwnr care In Pabrleating, handling, Shipin 1, Install and braelno. Refer to and DATE 10/01/14 /allow the lat.st rdM n or 7CSl 0,Adhg Component Safety ornotlon, y TPI and seCA) for safety 12pr� etkas prior io performing these functions. lrutallers ■hall provkk;Unporory �kw•saln psr 7CS1. .1' nand otherwise, top chord shall have properly attached struetUr&l shearo>tng a Iotton chord DRWG REPCHRD1014 ti shall have a properly at cFkd kl cell�s,y Laeatlons shown for permnant lateral restraint OF webs shall have brarJnp hr,ialhd per SCSI nctforu 73. 77 or 770, os appUeablh Ayp1Y plates to each face of *truss and poslticn as shown above and on the Joint Dttags, Lie sss raters('"rvlse, Refer to draringe 164A-Z for standard plot. position. Alpine. o dNlalon of ITV 7uAdho Components are Inc, shall not be respanslhla for a devlattan from AN rTWMMPANY t A drawing, any.fallure to W101 the truss In eon arnanee whh ANSI/TPl 1, or for hand g, shIppho, hsiallatbn 1, •�rocMp M *trustee - , A ssol•on this miraring or 4over pape 14*tMg *tNs dr•arF,g. kwhxtez aes.ptanct of profsmrsbnel A resporulbllh�y solely for the desqn showm Tha a tohgty aril List of iNs draift -(�J 133wg Lskeholll Odve for any sirueturr is trig responsOAhy of tlx ILiIIW4 Designer per ANSUTPI I Sec., Eadhcky,AAOe3o45 for non Intornaihn set thls Jobe general notes ptpe and *these wob $lt►sr SPACING 24,0' MAX ALPINr, wrw,el ItMCanl TPL weetpkwt.org] SIC. wwwsbdndLidtryarg, 1CG wwwkesafe,erg pIT/ - A"8-0 414V Ir 0 0 0* 0 1111, .fig - c. .- 4 wi 0 v Al p 4 T08 N"44 i.,, STO -0115)VA VMlla 0 0 0' 0 -TQ NAW4. -a*4 IZU�W!puw TJL Aql-JDF,� NO ,Kcl L oz .0-1 `la Z)i- ia/Tb/ol .119JKCI V9 Q� O.S.. T 14 'pesq'aousl. Sit!? aye �;JIVN SAXON 0 .qA; *4ljl.-m.srnjL . -OT. sqN?C!j4:N'.FSQJ.L; P9T v 43pi4jadi-at-'piqoq lsllev=aal p9l.t oaAals. UR"OlOrt qllp.u-aotpgT.S 6up43im4s; Uf �610U'Psxl.el -ulpilo.A sliou.-PPOTP91 v GA r, -q i8 6q i "PPQMAlO,-A fi h PJ tA. J c; TIMM M idrt WR sdollgoo) ajddp*jleyl. 0s 'AlrW ral-) 10d OZ• pifli!l (-U) isd og,.Ip* p;jo-ji,.qat4d� Buaw ua�m 5�0'1 Po �if Mo VA';Ill sajjdda:SM**B sktiL a sm-41-4W 'aW*IL AU9A3"WVaS P". lluam- AuAlind J2"* jq" J6D -PIL;bq a "Mijimlinh flirril-1117irl -'Aningi pug aZI.. aamum �0 On) daVOB 009 ON 0 AATIVA Face -Mount Hangers - I -Joists, Glulam and SCL .............._.................................................._..._.............................................................................................................................................. . s ; These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. Elm Elm 0 .r_ Carried Dimensions Fasteners Allowable Loads " Member ,;Actual .,,, , DFlSP SPF/HF Joist Model . Mln i Cnde Size"No E Web ; t Mail �. Species Header Species Header Ref. m. ( ) `�' Sliff _ Reqd. W H ,,"� B - Face' Joist Uplift' Floor Snow Roof Floor Snow Roof' (160) (100), (115},', (125) (100), (115) (125) Min. (14) 0.148 x 3 - 1-0 1,660 1,805 1,805 1,425 1,555 1,555 IUS2.56l16 - 25/s 16 2 Max. (16) 0.148 x 3 - ,n r 1,30 8 r 1,.,J� r 1,8ua 1 }55 .�.� a rrr „� �� 11555 21/2 x 16 MIU2.56/16 • - 29ti6 157/6 21/2 - (24) 0.162 x 31/2 (2) 0.148 x 11/2 230 3,455 3,920 4,045 2,970 3,370 3,480 U314 • ✓ 2% 101/2 2 - (16) 0.162 x 31/2" (6) 0.148 x 11/2" 970 1,945 2,205 2,375 1,675 1,895 2,045 HU316 / HUC316 • ✓ 29ti6 141% 21/2 - (20) 0.162 x 31/2 (8) 0.148 x 11h 1,515 2,975 3,360 3,610 2,565 2,895 3,110 IBC, MIU2.56/18 • 29It6 177%6 _ 21/2 - (26)0.16 '2 x 31/2- (2) 0.148 x 11h 230 3.745 4,045 4 045 3;220 3,480 i 3,480 LA 211z x18 'HU316,/°HUl0- 6 "' ✓ . 2s46 r ' 14,16 : c 2l"2"z : - 1 "� r(20)-0162 x 3Iz; , .(8) 0.148,K 1 h ". �:1515 2,975" 3,360', 3,610 2;565 i e 2,895 3,110; 21/2 x 20 MIU2.56/20 - 29H6 197/16 21/2 (28) 0.162 x 31/2 (2) 0.148 x 11/2 230 4,030 4,060 4,060 3,465 3,495 3,495 21/2x"22 % �<'to MIU2.56/20 ✓" " 29/i6 , 197/+6 21h - {28)"0:1'62 x 31h " "(2) 0.148 x 11h '' ' 230 4,030. 4,060'' 4,060: 3,465 3,495I jj 3,495 26." ." `i 29/16 x 91/4 to 26 29ti6" wide joists use the same hangers as 21/2" wide joists and have the same bads. 777-77 -�MIU3.1219 a 9''l6' _2.'l2 -' � (16) 0":162 x 3 �' (2).0:148 x 11Iz ; � 230 2 3'05 2,615'- 2,82Q "1,980 � 2,245 2,425"; 3x9'h: HU210-21 HUC2i0.2" ✓ i `3'Is E 81%` V/z Max. ` {18) 0.162 x 3'h (10) 0.148 x 3 `' .,a,:5 2;6K 3,020 j 3,250r 2,305 2,605'2,80& IBC, MIU3.12/11 - 31/e 111/a 21/2 - (20) 0.162 x 31/2 (2) 0.148 x 11/2 230 2,880 3,135 3,135 2,475 2,695 2,695 FL, 3 x 117/e HU212-2 / FIUC212=2, ✓ 131AI 109A. 21/2 Max.. (22)"0.162 x 31/z "' • (10) 0.148 x3-, 1,795 3,275 3,695 3,97012;820 -3,180 3,425' "-LA HUC3 25/16'. Jr/4 id'Yifi.« [Y2 Max. "(26) Q,162x 3'I: " " (12) 0.148 z 3 i95 3,870 4;365J 4,695°5;830 .3,755 i 4,040i 31A,Qlulam ''' HUCO210-2-SDS �.' ' , 317a 9,^. ` . " 3'" - •(12)1la'"'`x 21/2„ SDS (6)1/4" x21h" SDS 2,345 1, 1 4. 75 1,.15. 3; (u "3;710 3,77,0: FL HGUS325`/'10 3'74 _ 86/s a 4 - (46� 0062 x 3?h ", (16) 0.162 x 31I2 :4,095 9,100 9,100 9.100 7�825 7,825 7,825~ IBC, HGUS3,25112 • 3 (56) 0162:, 31h, ."(20) 0.162 x 31/2 5,040. 9�400 9,400,1 �9,400" 8,085 8,08518,085 FL SD l " (16)1/4"x 2 5556;20fLGU3.25 31 a , '4,840 a261S o,2ci' HHUS46 - 35/a 51A 3 - (14) 0.162 x 31/2 (6) 0.162 x 31/2 1,320 2,785 3,155 3,405 2,395 2,715 2,930 3'/2 x 51/a HGUS46 • - 35/s I 0. 4 - (20) 0.162 x 31h (8) 0.162 x 31/2 2,155 4,360 4,885 5,230 3,750 4,200 4,500 HUS48 '"` + •. - 131h6 615116 2 :'- (6) 0,162 x 31h (6) 0.162 x 31/2 1,320 1,595 1,815' 1,960 1,365 1,555 1,680' IUS3.56/9.5 MIU3.56/9 U410 HUS410 HHUS410 31/2 x 91/2 HU410/HUC410 HUC0410-SDS HGUS410 LGU3.63-SDS MGU3.63-SDS • - 35/a 1 91/2 2 1 - 1 (10) 0.148 x 3 - 70 1,185 11,345 11,455 11,020 11,160 11,250 • - 39A6 81 A6 21h - 1 (16) 0.162 x 31/2 (2) 0.148 x 11/2 210 2,305 2,615 2,820 1,980 2,245 2,425 • ✓ 39AG 83/8 2 - (14) 0.162 x 31/2 (6) 0.148 x 3 970 2,015 2,285 2,465 1,735 1,965 2,120 • - 39/16 815/16 2 - (8) 0.162 x 31/2 (8) 0.162 x 31/2 2,990 2,125 2,420 2,615 1,820 2,070 2,240 • • - 36/6 9 3 - (30) 0.162 x 31/2 (10) 0.162 x 31/2 3,565 5,635 6,380 16,44514,845 5,486 5,545 • • • ✓ 39ti6 1 8% 21/2 - (36) 0.162 x 31/2 (12) 0.162 x 31/2 3,235 7,460 7,460 7,460 6,415 6,415 6A15 • - 139A6 9 3 - (12)114" x 21/2" SDS (6)1/4" x 21/2" SDS 2,265 4,500 4500 4,5001 3,240 3,240 3,240 • - 35/a 9'/,6 4 - (46) 0.162 x 31/2 (16) 0.162 x 31/2 4,095 9,100 9,100 9,100 7,825 7,825 7,825 IBC, • - 35/9 8 to 30 41/2 - (16)1/4" x 21h" SDS (12)1/4" x 21/2" SDS 5,555 6,720 6,720 6,720 4,840 4,840 4,840 LA • - 35/a 91/4 to 30 41/2 - (24) 1/4" x 21h" SDS (16)1/4" x 21/2" SDS 7,260 9,450 9,450 9,450 6,805 6,805 6,805 -`,'`:351a 117/6° ° ' 2 ,- ; (12)`01a8 x"3_ 70 1,420 1635 1,745 { i220' 1,390'"1,485' ` • = 39 1� /z 1/z ' 21" 8 53,13" ,75. 2,69 28,695 • • " , " ✓` 139/+6 .10' 2- (16) 0`.162•x 31/2 (%0.148 x 3 " . l70 "2,305" 2,615;12,820 1,990] 2,245, 2,425� HHU6410'> • • . - 13% � , 9 = 3 (30) 0.162 x 31/2'(10) 0.162x 31h , 5 6,380' 6,445I4,845 5,486 15,545 Hiteai�` ° e =Pay" m6inin9Yg1 : • nrnn1F�>Y,41A ri 1,4n?s �F-97g19S4n397gr - - " 1 "��] Max. " (22);0+162 x 31/x " (10} 0148:z 3 " `.,a 5. 3,275° 3,695 3,970 2;820T� 3,180 3,425. HUC0412rSDS " • • - 3s/+6 11" ii, - (14)1/a' x 21/2" SDS '(6)1/4" x2V2"-SDS 3013 6 iG �6 it HGUS412 ` , ' ' ." . t 1,35A 1034c� _' ,�4 - = t ' (56)"0.162 x 31 h .. , (20) 0,7..62 x 31h 5,040 "9,400 9,400I! 9,400 1 8085 P 8;0851 8,085 t GU3.63 SDS: °. ,• �� - E 3/a .8 to 30 4�/2 = {16)1149`x 2Yz" SDS (12)1/4" z'�2'I2" SDS 5,555' 6,720" 6;720 6,720 4;840 4;840 1 4,840 46 See footnotes on p.150. THA/THAC Adjustable Truss Hangers �v`�@ERfp W 7, G This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower installed cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table y Finish: Galvanized. Some products available in ZMAX11 coating. L See Corrosion Information, pp.13-15. O. 0 Installation: d CUse all specified fasteners; see General Notes. O The following installation methods may be used: 0 N Top -Flange Installation — The straps must be field formed over the header — see table for minimum top -flange requirements. IF= Install top and face nails according to the table. Top nails shall d e not bwithin 1/4" from the edge of the top -flange members. For - M the THA29, nails used forjoistattachment must•be driven at an d angle so that they penetrate through the corner of the joist and into the header. For all other top -flange installations, straighten the double -shear nailing tabs and install the nail's straight into the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, with at least half of the required fasteners in the top half of the header. Not all nail holes in the straps will be filled. Nails must have a minimum 1/2" edge distance. Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min.) installation option accommodates conditions where the supported member hangs either partially or entirely below the header. • Face -Mount (Max.) Installation — Install face nails according to the table. Not all nail holes in the straps will be filled except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift — Lowest face nails must be filled to achieve uplift loads. Options: • THA hangers available with the header flanges turned in for 35/e" (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart 13/4 for THAC422 for 122-2 126-2 THAC422 Face nails Top nails per table per table 13/: typical 21/2' for THA422-2 and THA426-2 THA418 Double 4x2— 2face nails Use full table value (total) Single 4x2—� 4 top nails See (total) nailertable Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps may be installed straight or wrapped over with tabulated face nails installed into top and face of heads ® Double -Shear a Double Dome Double Shear Shear Nailing Nailing Side View S Nailing Side View; (Available on Do not Top View 00bend tab some models) `4-1 Straighten the double shear nailing tabs and install nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation ryNrcui r nfrca Top Flange Installation er to tnote 5 p.187 86 Simpson Strong-Tle® Wood Construction Connectors M SIMPSON THA/THAC Adjustable Truss Hangers (cont.) H E These products are available with additional corrosion protection. For more information, see p.15. 1. Uplift bads have been increased for earthquake or wind bading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. 3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 1'h" min. top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-pty 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 1'h" naib in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried Qoist) member. Based on the installation condition, nails will be installed either straight with straighted double -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 18 Simpson Strong=Tie® Wood Construction Connectors SIMPSON Face -Mount Joist Hangers SERBp This product is preferable to similar connectors because PCs '�+ of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. The double -shear hanger series, ranging from the light -capacity LUS hangers to the highest -capacity HGUS hangers, feature nnovative double -shear nailing that distributes the load through Iwo poinl:s on each joist nail for greater strength. This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than'the HUS or THA hangers, while providing greater load capacity, and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stairiless steel or ZMAX8 coating: See Corrosion information, pp.13-15. Installation: - Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the.table-loads. 'NbT designed-f& welded or nailer applications._ - Options: • LUS and MUS hangers cannot be modified Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart Double -Shear Nailing Top View " s Double -Shear Nailing Side View Do not bend tab Dome Double -Shear <' Nailing Side View a` (Available on some models) 1' for 2xs 1'fis forU; C, Q H •V m:. B LUS28 HHUS210-2 Ili MUS28 A wt ®i/ HUS210 (HUS26, HUS28, and HHUS similar) Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 8 SIMPSON LUS/M US/H US/H H US/HGUS Face -Mount Joist Hangers (cont.) SS' SS SS+ Model' No Min Heel=a He�ghf Ga":" Dimensions (in ) Fasteners W H g4 Carrying Carried Member Member - Single 2x Sizes LUS24 25/a 8 18, 1 s/a 3'/e '.1 K • (4) 0,14$ x 3. "- ,(2) 0.198 x 3 LUS26 41/a ' 1 eke 131n �� '1 ?lay _ .(4) 6148:X 3, " (4) 0,148 x 3 MUS26 4"fi6 18 19/e 5IA6 2 (6) 0.148 x 3 (6) 0.148 x 3 HUS26 4IN 16 15/a 5a/a 3 (14) 0.162 x 31/2 (6) 0.162 x 31/2 •12 5% "' . 5t 1 (20)' Q E162 x-3'Iz.. `(8) 0.162.x 31h s 1 -3LUS28 (4) 01'48X' MUS28 65A6 18 19A6 61-a 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS28 61/2 16 15/a 7 3 (22) 0.162 x 31/2 (8) 0.162 x 31h HGUS28 61A6 12 15/8 71/a 5 (36) 0.162 x 31/2 (12) 0.162 x 31/2 Via, 0.148'"x•3 .' 16 _,. 15la = '" ° 9': (30) �0f62 X 31/z {10) 0b2,7F31h " HGUS210 89hs`' _ "e 12 " 15h " .." �91/e' `; 5` `(46)-0'x 3'h +(16) 0.162x311z ; 1. See table below for allowable loads. No: upiiftl - Floor Snow _, .(100) ' (115), ..=I These products are available with additional corrosion protection. For more information, see p.15. ® For stainless -steel fasteners, see p. 21. Many of these products are approved for installation B with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Wind Ref. `{ _Sindle'2iSiies ..-.-." - 1,070 1,150 1,475 865 635 725 785 1,000 IBC, FL, 560 ` - "1'; 6+0, .1 60, 955 1;090 1,180 1'2:5 LA 3:28i 1 3.280 1 3,280 1 1,150 1 2,350 2,660 1 2,780 2,780 HGUS26 -. -.� $ = t1340;; 4,850 �, : 5;170 ";' 5,390' $75 " "''4,690 `-5,220 " . 5390 " 5�390 - .70- 3;225 :" 3;610 -3,870.�.' 3,985' IBC, FL LUS28 1165 1100 1260 1350 1725 1165 1,195 1360 1,465 1,730 865 810 925 1,000 1,270 00� 1 -75-� '2,",125 ;; f '�5 , 2J ° i,1,$75 `"2,13b „ �2 2Cs5 _2 __' ,1;i 0 1,270 145 1 57Fx .. i. 55 F IBC FL, LA HUS28 i,760 4,095 4,095 4,095 4,095 1,760 4,095 4;G95 4,095 4,095 1, /180 3,520 3,520 3,520 3,520 HGUS28 1,5 Q . ' 275r' ; 7,275 "' :7,275" ;' 7,275 =1;853 ' 3,275 ", 77 '" 7,275 7275 1:2M 3,679` ' 3,820 3,915 4,250 IBC, FL LUS210 1,165 1,335 1,530 1,640 2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,500 IBC, FL, HUS210'' f 2,635 5,450 5r.795 . `5,830" 0,8, Z 635 , 5.395 5,780 U30 5- K .27220 :2,SY 21455, " 2£535 2,825 LA HGUS210 2,090 9,100 9,100 9,100 9,1o0 2,090 9,100 9:00 9,100 9,100 11545 6,340 1 6,730 6,730 1 6,730 13C;FL 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp. 98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45° and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45". Allowable loads are: HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table load 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square out 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load Acute side 0°?, w, Specify angle Top View HHUS Hanger Skewed Right foist must be bevel cut) All joist nails installed on the outside angle (non -acute side). U Z �C a 0 0 U w H 0 Z O cc F- Z U) 0 N m 0 N U U 94 0 z a 0 0 Z z 0 z 0 w a CD rn 0 0 0 N U 0 Simpson Strong -Tie® Wood Construction Connectors SS= 7. These products are available with For stainless Many of these products are approved for installation additional corrosion protection. ED steel fasteners, 6 with Strong -Drive° SD Connector screws. For more information, see p.15. see p.21. See pp. 335-337 for more information. SIMPSON I�tx'~tiiIlgl� Dimensions (ip) ,Fasteners (in.) DFISP"AilowapleiLoads- '� ; SPF/HE,Alloviiahle Loads Double 2x Sizes HHUS26-2 I4-A6 1 14 3-A6 53A 1 3 1 (14) 0.162 x 31/z (6) 0.162 x 31/2 1 1320 12,830 13,190 13,415 14,25011,135 12,435 12,745 12,935 13,655 HGUS26.2 I 49A6 1 12 3% 57/16 4 1 (20) 0.162 x 31/z (8) 0.162 x 31/z 12,155 4,340 14,850 5,170 15,575 11,855 13,73014,170 14,44514,795 oiz z� t 3i�,, r,yyu r;oru .c,uau aiu •,1,10u, a,cou 1,3oa );14o. IBG, FL, 31h , 1.760 14,26514,8110 1 5,155' ' 9801 1,515' 3,670 '4,135. 4,435 5;145 LA LUS210-2 67/a 18 31/a 9 2 (8) 0.162 x 31/z 1 (6) 0.162 x 31/z 1 445 1,830 2,075 2,245 2,830 1;245 1,575 1,785 1,930 2,435 HHUS210-2 83/s 14 35iia 87A 3 (30) 0.162 x 31/z 1 (10) 0.162 x 31/z 3,550 5,705 1 6,435 1 6,485 6 485 3,335 4,905 5,340 5,060 5,190 HGUS210-2 I 89/16 12 1 35A, 93/ifi 4 (46) 0.162 x 3Yz (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 9,100 3,520 7,460 7,825 7,825 7,825 Triple 2x Sizes HGO926-3 ,` 4t3/i6' ` 12 47% 51h . 4 (20)'0.16ix'W z" (8) 0.162 x 31h 2,155 4',340.14,850 5 70 5;575 1,855" =3,730 4,170. 4,445 4,795 _ IBC, FL, ,HfiUS28 3 ' 6*6 ; 12" 475/i6 71/a wq. :(36) 0.162z31/z '{12)O;162x,31h 6 3,235 7460 7460 7;460 �._._._ 7460 2,780 :6,415 6,415, 6,415 6,4. 5: LA HHUS210-3 83/a 14 417Ar 87/a 3 (30) 0.162 x 31/z (10) 0.162 x 31/z 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL HGUS210-3 81% 12 415A6 91/4 4 (46) 0.162 x 31/z (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 9,100 3,520 7,825 17,825 7,825 7,825 LA Quadruple 2x Sizes }1GUS26;4 5'h ' 121" 69A6 57/16 e4 (20)0�162X3✓z ` 8)'0.162X�31h ,2,155 4,340!, 4,850 5170 ,5,575 1,855 �3;730 4170 4,445 41J95 IBC, FL, HGUS28-4 71/4 12 1 6a/,6 73fi6 4 (36) 0.162 x 31h (12) 0.162 x 31h 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6, 1516,4151 LA HHUS210-4 83A 14 1 61/e 87/8 3 1 (30) 0.162 x 31h (10) 0.1$2 x 31/z 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 15,575 1 FL 0 J LUS46 ~ ,_' E 4% 71 18'; r'o 0 4x Sizes x FL, LA IBC, FL LUS48 ; 43/a 18 31A6 63/4 2 (6) 0.162 x 31h (4) 0.162 x 31/2 1,060 1,315 1,490 1,610 2,030 910 1,130 1,280 1,385 1,745 IBC, FL, HUS48 61/a 14 31A6 7 2 (6) 0.162 x 31h (6) 0.162 x 31h 1,320 11,580 1,790 1,930 1 2,415 1:135 1,360 11,540 1,660 2,075 LA HHUS48 61/z 14 35/a 71/8 3 (22) 0.162 x 31/z (8) 0.162 x 31/z 1;760 4,265 4,810 5,155 5,980 11515 3,670 4,135 4,435 5,145 HGUS48 67/16 12 35/a 71% 4 (36) 0.162 x 31/z (12) 0.162 x 3'h 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 LUS470. 61/a =186 3a/+4 83/4, 2 :. (8) 0.T62 x 31Wz ` (6) 0AU x 31/z ':'445 '1,830� =2;675 4; 451 2 830 i 2ai3-.k1,575 1,785 1,930 2;43'5 HGUS412 1 10346 1 12 135/e 110346 4 1 (56) 0.162 x 31/z (20) 0.162 x 31/z 15,695 9:045 19,045 19,045 9:045 1 4.900 17,780 1 7,780 17,780 17,780 HGUS414 1 117/,6 1 12 1 35A 11016l 4 1 (66) 0.162 x 31/z (22) 0.162 x 31/z 5,695 10,125 10,125 10,125 10,125 4,900 18,190 18,190 18,190 18.190 Double 4x Sizes Hf l 1.47 n7/in I R7/,G 1? 1 73/ 1 R9F drafit.n 1 F? Y 31A I d7F1 n 1 R? Y 31h. A-dZn I a oQ.,, 1,4 n45 a nQF 'o,n95 I 9 Q5n `7 R9n I .7 Rbn `' 7 R9n 7 Rgn FL, LA FL 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads. For loss than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVrPI 1-2014. Simpson Strong Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 5. Loads shown are based on a two-pty 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h" nails in the header and 0.162' x 31h' in the joist, with no bad reduction. With single 2x carrying members, use 0.148' x 1112" nails in the header and 0.148" x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 19 Simpson Strong-TieO Wood Construction Connectors Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/e". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is 1/a" per ASTM D1761 and D7147).'See technical bulletin T-C-HANGERGAP at strongtie.com for more information. Material:16 gauge N Finish: Galvanized I - Installation: V • Use all specified fasteners; see General Notes C• Can be installed filling round holes only, or filling U round and triangle holes for maximum values N • See alternate installation for applications using the HTU26 on a 2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity G1........ Options: -._...-. _.._,..,-� _.._... C. HTU may be skewed up to 671/2'. See Hanger . Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie:com for installation with Strong -Drive® SD fasteners. Codes: See p.12 for Code Reference Key Chart Min. heel height per table ! Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. HTU26 11m Typical HTU26 Minimum Nailing Installation y..r ,......, truss and carrying member HTU Installation for Standard Allowable Loads (for 1/2" maximum gap, use Alternate Allowable Loads.) St 05:9.7 Alternate Installation - HTU28 Installed on 2x6 Carrying Member (H7U210 similar) 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1/a" and 1h", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVrPI 1-2014. Simpson Strong -Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 1 Y2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 96 SIMPSON HTU Face -Mount Truss Hanger (cont.) i Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member ea„� i u or ;Migimi HTU26 (Min.) 37/a (2) 2x4 (10) 0.162 x 31h (14) 0.148 x 11/2 925 1,470 1,660 1,790 1,875 795 1,265 1,430 1,540 1,615 HTU26 (Max.) 51/2 (2) 2x4 (10) 0.162 x 31h (20) 0.148 x 11/2 1,240 1,470 1,660 1,7900 2,220 1065 1,265 1,430 1,5 '0 1,910 IBC, NT4728' Max 71/a ' (2) 2x6 (2Q) 0.162 x 3 h (26) O. 48 x 1'h " 1,970 2 940 '�,32 � �,58v' 3,905 ` .7 695 ,2,530 2 855 3 "3,J8i� 3,360 FL, LA ( )... f 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 1h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loads (1/2" Maximum Hanger Gap) Min. Dime nsions (m) Fasteners (m ), Motlel Heel. arrvinn ''Carried Single 2x Sizes Wind 1,955 1,1,955 [ 1,955 11,955 " IBC, HTU28 (Min.) 37/a 15/s 71'Aa 31/2 (26) 0.162 x 31/2 (14) 0.148 x 11/z 1,114 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL, LA HTU28 (Max.) 71/4 1 5/8 7'As 31/2 (26) 0.162 x 31/2 (26) 0.148 x 11/2 1,920 3,820 4,31 4,655 5,015 1,695 2,865 3,235 3,4::0 3,765 HTU210 (Min.) . " 37/a • 15/8, 91/4c ; 31/2. (32) 0162X•3112 (l"4} 0:148 x.11h 1250" 3;600 3,fi00 3,600 3;600 '1,075 � 2,70 ' 12,700 2,70.0 , 2,700 Double 2x Sizes HTU28-2 (Min.) 37/a 35/111 1 7'f s 1 31/2 1 (26)'0.162 x 31/2 (14) 0.148 x 3 1,490 3,820 3,980 3,980 1 3,980 1 1,280 1 2,865 2,985 2,985 2,985 IBC, FL, HTU28-2 (Max.) 71A 3,1/1s 1 71/is 1 31/z (26) 0.162 x 3% 1 (26) 0.148 x 3 3,035 3,820 4,315 4,655 15,520 12,610 12,865 3,235 3,490 41,14e LA 1 48 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govem. 4. Wind (160) is a download rating. 5. For hanger gaps between %" and 1h", use the Alternate Allowable Loads. B. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector" software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 41855 HU/HUC/HSUR/L Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUC products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension is 25/16" or greater, at 100% of the table load. Specify HUC. • HU is available with one flange concealed when the W dimension is less than 25/16" at 100% of the table load. Specify as an version and specify flange to conceal. • For any HU or HUC shown in this catalog, the user may substitute all face nails with 1/4" x 13/4" Titen® 2 screws (Model TTN2-25134H) for concrete and 'A" x 234" Tften 2 screws (KA1o0el T fN2-25234hf for GFCMU. Follow all installation instructions and use the loads from the sav>n lumber or EWE' sections. Material: 14 gauge Finish: Galvanized; ZMAX® and stainless steel available Instal(ation: • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" — Model TTN2-25234H) and for concrete (1/4" x 13/4" — Model -fTN2-25134H) are not provided with the hangers. • Drill the 3/16"-diameter hole to the specified embedment depth plus'/z". • Altematively, drill the 3/% diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Titen Installation Tool Kits are available. They include a V116" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/16" x 41/2" drill bit is also available (Model MDB18412). • A minimum edge distance of 11/2" and minimum end distance of 37/e" is required as shown in Figure 1 for full uplift load. • Where no uplift load is required, a minimum end distance Of 11/2" is pemitted. Codes: See p.12 for Code Reference Key Chart Concealed flanges HUG410 SIMPSON yyy V_ ks, HU214 Figure 1 — HUG410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 23 SIMPSON HU/HUC/HSUR/L Medium -Duty Face -Mount Hangers (cont.) Ob These nrodiicts are availahle with additional corrosion nrotection. For more information. see n.15. Model fasteners :Allohrabte�loads(D�%SP) = N0 GFCMU Concrete' Code Standard Coricealed GFGMU Concrete Ttten®2. Jolst lift CJ left Op :°(16D) a Down (100/125); Uplift (i60) a Down (100/125),,' Ref HU26 HU26X (4)1/4 x 23/4 (4) 1/4 x 13/4 (2) 0.148 x 11/2 335 1,000 335 1,545 HU28 ; HU28}(i (6} ya;7( 23/a� `',(6)?!a x'1''a/a r 345 1500' 6Q° 2 400. HU24-2 HUC24-2 (4)1/4 x 23/a (4)1/4 x 1 % (2) 0.148 x 3 380 1,000 380 1,545 HU26-2.( HUC26.2 " (8)1/ax 23/d - (8) l4 X 1�/4 4) 0:148"x,3 760 2,000 760 ` , ,. 8 200 ' HU26 2 (Max } _ HUC26;2 (12}1 _ _ 1,135x HU26-3 (Min.) HUC26-3 (Min.) (8)1/4 x 23/a (8)1/4 x 13/4 (4) 0.148 x 3 760 2,000 760 3,200 HU26-3 (Max.) HUC26-3 (Max.) (12)114 x 23/4 (12)1/4 x 13/a (6) 0.148 x 3 1,135 3,000 1,135 3,950 HU28-2 (Mm ). „ 3 HUC28 2 (Mln) _'' (10j y/Wx 23/4 {10)`?/e x.1.3/4 ' (4) 4.148: x 3 , ° - 760 , , ;, 2 500 : ` , , .., 760 HU210 HU21OX I (8)1/4 x 23/4 I (8)1/4 x 13/a I (4) 0.148 x 11/2 I 545 I 2,000 760 I 2,415 HIt91(1=9dM1Ain1'' Nll!.,9,1As9Winl'. lidll/�`v93/- d{.1J.v,13/. /F1l1'1$Rv+ ..;f:"i"2G 4Rnn. s1'1 5- GA9n•":?' nUL �V :G tIVIdXj nUUL IU,L �IVIdxJ (Ip)/4,XL/d _ 116)/4x 1'Y4 t,l U�U i48 X;3 1L}UU : YaW i; IOUV ,a U6.7 HU210-3 (Min.) HUG210-3 (Min.) (14)114 x 23/a (14)1/a x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210.3 (Max.) HUC210-3 (Max.) (18)1/4 x 23/a (18)114 x 13/4 (10) 0.148 x 3 1,800 4,500 1,800 5,085 HU 1a(10212H 1135 3U212 5 „„ 2a665 HU212-2 (Min.) HUC212-2 (Min.) (16)1/a x 23/4 (16)1/4 x 13/4 (6) 0.148 x 3 1,135 1 4,000 1,135 41920 HU212-2 (Max.) HUG212-2 (Max.) (22)1/4 x 23/4 (22)114 x 11/, (10) 0.148 x 3 1,350 1 5,085 1,350 5,085 HU214 I HU214X I (12)1/4 x 23/4 ( (12)1/4 x 13/4 1 (6) 0.148 x 11/2 1 1,135 1 2,665 1 1,135 1 2,665 1 HU214-3 (Min.) HUG214-3 (Min.) (18)114 x 23/4 1 (18)1/4 x 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 HU214-3 (Max.) HUC214-3 (Max.) (24)1/4 x 23/4 (24)1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 10216- HU216>�0 (1$)_1/ax`23/4 {18}11az13/a `(8)k148x1?/z 1-515 2;920 151'5 219 HU216-2 (Min.) HUG216-2 (Min.) (20)1/4 x 23/a (20)1/4 x 13/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUC216-2 (Max.) (26)1/4 x 23/4 (26)1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 H , 216-3 (Mln )p w� HUC216 3 (Min.), `= j20j,1/a;x'23/a ` (20)1/a z 13/a rn{8) 0, I48 x 3 1575 4 920 '? 1,515 4 920 HU2163 (Max) : ' HUC216'3 (Max) (26)1/ax 231a F', . (26)114�x"l3/a , ._ {12) 0.148 z 3' 5�085 HU7 (Min.) (Not available) (12)114 x 23/4 (12)1/4 x 13/a (4) 0.148 x 11/2 545 2,980 760 2,980 HU7 (Max.) (Not available) (16)1/4 x 23/a I (16) %x 13/4 (8) 0.148 x 1112 1,085 3,485 1,085 3,485 HU11 (Min.) (Not available) (22)1/4 x 23/a (22)1/4 x 13/a (6) 0.148 x 11/2 1,135 3,230 1 1,135 13,230 HU11 (Max.) (Not available) (30) 1/4 X 23/4 (30)1/4 x 13/4 (10) 0.148 x 11/2 1,445 3,735 1 1,445 1 3,735 38 STAGGER JOINTS - RAISED HEEL ROOF TRUSSES B/SKIS SEE PLAN RIBBON BOARD- SEE SCHEDULE FOR SPACING 4 FASTENING TO TRUSSES t, UPLIFT/SHEAR ANCHOR —I v —MASONRY WALL - EACH TRUSS - SEE B/SKI SEE PLAN PLAN NOTE: ADD'L FRAMING NOT SHOWN FOR CLARITY RAISED HEEL TRUSS BEARING A SCALE: NTS SKI ROOF SHEATHING- SEE 1 SOFFIT/FASCIA- SEE ARCH. RAISED HEEL ROOF TRUSSES -5EE PLAN N O ITTRIBBON BOARD- < Q 3 SEE SCHEDULE U z d FOR SPACING 4 Z 52 0 w uj W FASTENING TO w U > U<QQ TRUSSES w o _ z01 WALL SHEATHING -SEE PLAN = a Z 3 MIN, 15/32' CDX PLYWOOD OR w 1116' 05B WITH 8d GUN NAILS I C U (0.131' X 2 1/29 ® 6' O.C. TO UPLIFT/SHEAR GYP. CEILING- RIBBON BOARDS ANCHOR EACH SEE PLAN 4 TRUSS- SEE PLAN SCHEDULE DO NOT FASTEN RIBBON BOARD INTO END GRAIN OF ROOF TRU55 MASONRY WALL - BOTTOM CHORD SEE PLAN _ _ ��-PEVISU RAISED HEEL TRU55 BEARING B $CALE, NTS SKI RIBBON SCHEDULE; DESIGN CRITERIA FIB56N MATERIAL RIBBON SPACING RIBBON ATTACHMENT Yult=165 MPH (2) 12d GUN (0.131' X 37 (vasd=128 MPH) 2X4 SPF92 24' TO EACH TRUSS, (4) EXP. B, NAILS AT JOINTS ENCLOSED vull=180 MPH (2) 12d GUN (0.131' X 39 (Vasd; 139 MPH) 2X4 SPF02 16, TO EACH TRUSS, (4) EXP. C, NAILS AT JOINTS ENCLOSED SHEETTITIE: R-ON 01-FOR Rniseo nai Roa rRussFs SHEET INFORMATION: nano: aama SK.1 ,AN.'rTWC0.V,PA*, ,January 19,�.2020. _Catp-6fiWi-,Coiitr.actors of America, Winter.1fAvem FL 3388QR62Q:1 DearMatt: ,It has come my attention ., . thalsqme questions were raised concerning Si/ 1 8". diameter gable end trusses -i" Ilow.f6r, w'ns'i;' If,,th"ese';,,gable,,ends,:are,over',.co4o.pitqu$ support vviih 6A:,.0,fac, e,hilly-,-,�'hW"th eid aJh" . ` , 'd fate n c ose an;40Ct OUt a any pates:,orvertical Ythen. n nolrep*trls Te. Wrqd.Tbe. truss on! .sVgports,., fo6vof, fll6otAba&:. dhd nd; add itional q load. Ifyoix have any questionsplease give me a;caIl, Shie&ely, I Y, I WA/f� *4 CN STATE: OF 6750:Forum .bnVe- Suite ,80,. (Ott d (KQ) 521 -Q7.Q0 ­8685 R. 1 q., FL 3282 , I (86�)422., wwmalpinp.itWl..00.M.; and moo copi's I �vd ,0110fiiHWAf(�,�'tr'<� •t No.86367 5 1 STATE OF ALPINE ANITw:ZPANY FL REG# 279, Yoonhwak Kim; FL PE 086367 Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone: (800)755-6001 www.alpineitw:com Customer Carpenter Contractors of America Job Number: N372962' Job Description: ;7A5 j75EA ,RF01/ 1756lEASTHAM/EXPRESS Address: Y, Design Cade: FBC 2017 RES tntelliVIEW Version: 18.02.01 through 18.02.01 A JRef #: 1 WXK89750083 Wind Standard: ASCE 7-10 Wind Speed (mph): 160 Roof Load (pso 20.00- 7.00- 0.00-1.0.00 Building Type: Closed' Floor Load s :: None This package contains general notes pages, 33 truss drawing(s) and 11 detail(s). Item CTif;ferr�ng,t��1»ber Trissa ' ° 1 218.20.1558.07755 Al 3 218.20.1558.07318 A3 5 218.20.1558.07428 A5 7 218.20.1558.07037 AM 9 218.20.1558.09159 A7A 11 218.20.1558.09408 A8A 13 21.8.20.1558.08145 62 15 218.20.1558,09143 B4 1.7 218.20.1558.07209 C1'A 19 218.20:1558.04089 CJR 21 218.20.1558.07630 J66A 23 218.20.1558.07411 EJ56 25 218.20.1558,08753 CJ36 27 218.20.1558.08831 CJ1 29 218.20.1558.04091 CJA. 31 218.20.1558.08675 HJ56 33 218.20,1558,03901 HJB 35 A14015ENCi101014 37 A16015ENC101014 39 BRCLBSUB'1014 41 GBLLETIN0118 43 RIGINSRT1014 2, 21820.1558.07943 A2 4 218.20.1558.08223 A4 6 218.201558.09299 A6 8 218.20A 558.07287 A7 1,0 218.20.1558.09018 A8 12 218.201558.08410 B 1 14 218.201558:08146 B3 16 218.20.1558.07100 C 1 18 218.20.1558.07536 C2 20 218,20'.1558.08925 J66 22 218.20r1558.08644 EJ66 24 218.20.1558.07817 CJ5 26 218:20.1558.08285 CJ3 28 218.20.1558.07552 CJ16 30 218.20.1558,08472 HJ66 32 218.20.1558.04090 HJA 34 160TL 36 A14030€NC101014 38 A16030ENC101014 40 DEFLCAMB1014 42 GBLLETIN1014 44 STRBRIBR1014 Florida Certificate of Product Approval#FL1999 Printed 8/5/2020 4:03:00 PM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of'the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or 1310, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel'with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; ,S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.oro. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. U# = user specified divisor for limiting span/deflection ratio for evaluation of actual Udefl value. Udefl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, incldding creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1 Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.oro. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO 63043; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindust[y.com. Page 3 of 3 SEQN: 103462 / COMN Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T31 FROM: RWM Qty: 5 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07755 Truss Label: Al / YK 08/05/2020 6'4"4 _ 13'6"l0 + 20' 6'4"4 7'2"6 6'5"6 6X6 E 26'5"6 33'712 + 40' 6'5"6 7'2"6 6'4"4 40' 1' L 10' 10, 10, r r 10 '1 20' 30' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.276 K 999 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.482 K 988 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.085 J - - Des Ld: 37.00 EXP: C Kzt NA HORZ(TL): 0.148 J - - Code / Misc Criteria NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.793 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.902 Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: No Max Web CSI: 0.846 Loc. from endwall: not in 13.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): VIEW Ver: 18.02.01A.0205.19 Wind Duration: 1.60 WAVE Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 :132, B3 2x4 SP 2400f-2.0E: Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N: Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance �* 3ENsc�' AeS q No, 86367 s ®� ® STATE OF lcr w m 10, 1 40' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1678 /- /- /923 /333 /344 H 1679 /- P /923 /333 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.0 H Brg Width = 8.0 Min Req = 2.0 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1734 - 3551 E - F 1227 - 2270 C - D 1590 - 3234 F - G 1590 - 3235 D - E 1227 - 2270 G - H 1734 - 3552 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 3224 -1476 K - J 2618 -1126 L - K 2618 -1102 J- H 3225 -1478 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 324 -377 K - F 499 - 783 L - D 572 - 222 F -J 573 - 223 D - K 499 - 783 J - G 324 - 377 E - K 1353 - 636 P e Wind Wind loads based on MWFRS with additional C&C �A/`ul apr member design. /o//OAL Additional Notes Refer to General Notes for additional information FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, byy TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide tempora bracing per BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly attached rigpid ceilingp Locations shown forpermanent lateral restraint of webs shall have bracingq ins ailed per BCSI sections 63, 67 or 610, as aDDltcabla. AppTv Dlates to each face of truss and Dosition as shown above and on the Join Details. unless noted otherwise. f�efer to Of riri i,oriorr acceptance any structure failure to build the f or cover pa e n. The sui ability ALPINE *xrtwCw- 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:103365/ HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef:1WXK89750083T3 / FROM: RWM Qty: 2 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07943 Truss Label: A2 / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " rs 4 13'6'10 A 6'4'4 7.2"6 4'116 1'6 —14X6 013X6 :4X6 T3 evn E F G 40' - '+- 210' 0 10' ' Wind Criteria Snow Criteria (Pg,Pf In PSF) Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA Speed: 160 mph Pf: NA Ce: NA Enclosure: Closed Lu: NA Cs: NA Risk Category: II Snow Duration: NA EXP: C Kzt: NA Mean Height: 15.00 It Code / Misc Criteria BCDL: .2 psf BCDL:.0 psf 5 Bldg Code: FBC 2017 RES MWFRS Parallel Dist: h to 2h TPI Std: 2014 C&C Dist a: 4.00 ft Rep Fac: Yes Loc. from endwall: not in 13.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord 2x4 SP #2 N :T2, T5 2x4 SP #1: :T3 2x4 SP 2400f-2.0E: Bot chord 2x4 SP #1 :132, B3 2x4 SP 2400f-2.0E: Webs 2x4 SP #3 : W 3, W 4, W 5 2x4 SP #2 N: Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 26'S'6 + 33'T12 + 40' 4'11'6 T2'6 6'4' 10, 30' T— Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.315 M 999 360 VERT(CL): 0.549 M 867 240 HORZ(LL): 0.085 L - - HORZ(TL): 0.149 L Creep Factor. 2.0 Max TC CSI: 0.985 Max BC CSI: 0.907 Max Web CSI: 0.673 VIEW Ver. 18.02.01A.0205.19 `�141i119f111►///��I q�HWA,� No.86387 Z b @ yly a+ �STATE 0F 0 ° 10 1� 40' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1682 P /- /927 /339 /321 J 1682 /- /- /927 /339 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.0 J Brg Width = 8.0 Min Req = 2.0 Bearings B & J are a rigid surface. Bearings B & J require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1794 - 3564 F - G 1238 - 2073 C - D 1645 - 3236 G - H 1293 - 2290 D - E 1293 - 2291 H - 1 1646 - 3239 E - F 1238 - 2073 I - J 1798 - 3571 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - N 3237 -1533 M - L 2606 -1191 N - M 2606 -1167 L - J 3244 -1555 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - N 336 - 402 M - H 476 - 745 N - D 592 - 230 H - L 596 - 232 D - M 479 - 748 L - I 339 - 407 F - M 1255 - 589 1Q "� byes °tie Al FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 1 **WARNING** READ AND FOLLOW ALL NOTES ON TH **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS Of any as J UMMMIVVI INCLUDING THE INSTALLERS I.. Refer to and follow the latest edition of BCSI (Building T1Ing these functions. Installers shall provide temporarrvy Jctural sheathin� and bottom chord shall have a properly lave bracinccl1 ins ailed per BCSI sections B3, B7 or 610, on the JoinCDetaiI .unless noted otherwise. E7efer to failure to build the i or cover page , ,n. The sui ab111ty ALPINE ,wmvca+_ 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:103368/ HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef:1WXK89750083T21 % FROM: RWM Qty: 2 7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07318 Truss Label: A3 / YK 08/05/2020 6'4"4 136"10 16'6" 20' 23'6" 26'S"6 33'712 40' 6'4"4 7'2"6 2'116 3'6' 3'6" 2'116 7'2"6 1112X4 =5X5 =5X8 =5X5 E F G �_,44X4 T2 O H 12 D 5 W5 T4 �515 m �5X5 W (a) C (a) W3 r A B1-1 J =4X6(A2) -6X6 B2 =5X8 83 =6X6=4X6(A2) 40' 10' 10, 10, 10' 1 10' 20' 30' 40' Loading Criteria (pso Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.336 M 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.587 M 811 240 B 1682 /- /- /929 /346 /290 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.085 L - - J 1682 /- /- /929 /346 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.148 L - - Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Code / Misc Criteria Creep Factor. 2.0 B Brg Width = 8.0 Min Req = 2.0 TCDL: 4.2 psi J Br Width = 8.0 Min Re 2. Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.710 9 q = 0 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.908 Bearings B & J are a rigid surface. B & J require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 It Rep Rep Fac: Yes Max Web CSI: 0.763 Members not listed have forces less than 375# Loc. from endwali: not in 13.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver. 18.02.01A.0205.19 Lumber B - C 1839 -3566F - G 2265 -4006 C - D 1697 - 3235 G - H 1335 - 2307 Top chord 2x4 SP #2 N D - E 1335 -2307 H - 1 1697 -3236 :T2, T4 2x4 SP #1: E - F 2265 - 4006 I - J 1839 - 3568 Bot chord 2x4 SP #1 :B2, B3 2x4 SP 2400f-2.OE: Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) :W3, W5, W7 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Bracing B - N 3239 -1583 M - L 2603 -1234 (a) 1X4 #3SRB or better continuous lateral restraint N - M 2602 -1209 L - J 3240 -1607 to b1xspaced. (8d Box or Gun �`'IIp��' nas(013I2mn.). Restraint maerrial to be i,,�y�.�1`�,,'+A��� Maximum Web Forces Per Ply (Ibs) DOS supplied and attached at both ends to a suitable it �� e �•ir1 �^ Webs Tens.Comp. Webs Tens. Comp. support by erection contractor. A: �' °N 11 +A_ v f Y � �°T 1 C - N 337 - 403 O - M 1196 - 557 1`nA1�� (a) or scab reinforcement may be used in lieu of CLR �°+ • • N - D -231 O - 1064 +® 2593 --231 restraint. substitute (1) scab for (1) CLR and (2) q+ • o 459 L scabs for (2) CLR'S where shown. Scab 4 ® ��� m D - M 459 - 665 H - L 593 231 reinforcement to be same size, species, grade, and a • a E - O 2004 -1064 L - I 337 -403 80% length Attach 0.128x3" o M - H 459 -666 of web member. with gun • nails @ 6" oc. v • s w Loading ®• STATE OF o7W�� Truss passed check for 20 psi additional bottom i e F {� (� 'V .4 chord live load in areas with 42"-high x 24"-wide • C� 4- o V �q clearance. v •g�yyp�r• vq�, p S r p e Wind A Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building shipping, Component Safety for Information, bVV TPI and SBCA) sa practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingp and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or 810, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the -Co,,,,,,,, truss in conformance with ANSIITPI 1, or for handlin shipping, Installation and bracing trussesA this drawing of seal on or cover page . , 6750 Forum Drive listing this drawing, indicates acceptance of ro essfona engineerin responsibility solely for the design shown. The suitability Suite 305 �rawing plie Building and use of this for any structure is responsibility of the Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: —.al ineitw.00m: TPI: www.t inst.or : SBCA: www.sbcindust .com: ICC: w Jccsafe.org Orlando FL, 32821 SEQN: 103370 / HIPS Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T13 f FROM: RWM Qty: 2 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08223 Truss Label: A4 / YK 08/05/2020 6'4"4 14'6" 20' 25'6" 33'7"12 40' 6'44 8'1"12 5'6" 5'6" 8'1"12 6'4'4 :5X5 1112X4 =5X5 D E F T12 T2 5 � T4 9) �5X5 �5X5 'v C G or io W4Z B H IMA 1 1_+8,8" 4X6(A2) =6X6 B2 ===5X8 B3 =6X6=4X6(A2) 40' 1' 10' 10, 10' 10' 1' 10' T 20' 30' + 40' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.271 E 999 360 Loc R+ / R- ! Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.470 E 999 240 B 1698 /- /- /926 /396 /258 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.086 J - - H 1699 /- /- 1926 /396 P Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.149 J Wind reactions based on MWFRS Mean Height: 15.00 ItNCBCLL: 10.00 Code / Misc Criteria Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 2.0 TCDL: 4.2 psf H Brg Width = 8.0 Min Re 2.0 Soffit: 0.00 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.561 q = BCDL: 5.0 p Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Sid: 2014 Max BC CSI: 0.909 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0.305 Members not listed have forces less than 375# Loc. from endwall: not in 13.00 It FT/RT:20(0)/l 0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver. 18.02.01A.0205.19 Lumber B - C 1899 -3616 E - F 1600 -2838 C - D 1730 - 3272 F - G 1729 - 3274 Top chord 2x4 SP #2 N D - E 1600 -2838 G - H 1898 -3618 :T2, T4 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 :132, B3 2x4 SP 2400f-2.OE: Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. 04 2x4 SP #2 N: B - L 3287 -1642 K -J 2562 -1199 Loading L - K 2561 -1174 J - H 3288 -1666 Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide Maximum Web Forces Per Ply (Ibs) clearance. `,Ql��,r" Webs Tens.Comp. Webs Tens. Comp. Wind ��� Q e ♦Co�♦lt• rl ,j_� C - L 379 -428 K - F 412 -170 0 00i67 p-*;j L D 638 F J 639 270 - -270 - - Wind loads based on MW FRS with additional C&C `,� o `C E V,9 member design. �7 ♦ I mr D - K 413 -170 J - G 379 -428 No'636 J o Additional Notes y Refer to General Notes for additional information e STATE OF � 1 N re�� IS 0♦ooQo e d"4.44s'10NA� � �1 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an c7 SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proCerly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracln installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join f Details, unless noted otherwise. f�efer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Bu!ldincLqComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the w n �� ,.„ truss in conformance with ANSI/TPI 1, for handling, bracing trussesA this drawing or shipping, installation and of seal on or cover page , , 6750 Forum Drive listing this drawing, indicates acceptance of professlonaf engineering responsibility solely for the design shown. The suitability Suite For and use of thisawing for any structure is the responsibility of the Building Designer per ANSIITPI 1 Sec.2:305 For,more information see this lob's geDeral notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or ; SBCA: www.sbcindusl xom: ICQ ­Accmfe.org Orlando FL, 32821 SECiN:103373/ HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef:1WXK89750083T5 / FROM: RWM City: 2 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07428 Truss Label: A5 / YK 08/05/2020 6'4"10 12'6" 20' 27'6" f + 33'7"6 40' 6,4.,10 6,1„6 Y 7,6„ 7,6„ 1 Ml' 6„10 °♦ =5X5 1112X4 =5X5 D E F 12 5 � T T c2C4 rn zo � W3 2a;?,012G4 B 1 A H � 1 lo8-8- M 4X6(A2) .6X6 =5X8 -6X6=4X6(A2) 40' 10' 10, i _ 10, 10' 1' 10' T 20' 30' + 40' Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.321 E 999' 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.567 E 839- 240 B 1655 /- P /919 /727 /227 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.092 J - - H 1655 /- /- /919 /727 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.162 J - - Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Code! Misc Criteria Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 2.0 Soffit: 0.00 Bldg Code: FBC 2017 RES Max TC CSI: 0.771 BCDL: 5.0 psf H Br Width = 8.0 Min Re 9 q = 2.0 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.912 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0.530 Members not listed have forces less than 375# Loc. from endwall: not in 13.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18,02.01A.0205.19 Lumber B-C 1917-3480 E-F 1845 -3155 C - D 1771 - 3179 F - G 1770 - 3179 Top chord 2x4 SP #2 N D - E 1845 -3155 G - H 1917 -3481 Bat chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N: Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Loading B - L 3156 -1655 K - J 2653 -1329 Truss passed check for 20 psf additional bottom L - K 2652 -1304 J - H 3157 -1679 chord live load in areas with 42%high x 24"-wide clearance. 4I1/►/f/��I Maximum es Per Ply (Ibs) Wind OS\11i�1y'af Webs Tens.Comp.Webs Tens. Comp.. Wind loads edonMWFRSwithadditionalC&C Ir member design. ��5 ^ eA/•�a /p�P/�p� DK *�h,�� V �► Y V '°f� D-613 -330 F-J 527 -207 Additional Notes w • ,may E - K 343 -430 Refer to General Notes for additional information es No. B5367 • �O 0 �a STATE OFZORA FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices pnor to performing these functions. Installers shall provide temporary bracing BCSI. Unless noted have bottom have per ovherwise,top chord shall properly attached structural sheathing and chord shall attached rigid ceilincl Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections Apply face, a properly B3, B7 or 610, kefer as applicable. plates to each of truss and position as shown above and on the Join Details, unless noted otherwise. drawings 160A-Z for standard plate positions. to ALPINE Alpine, a division of ITV Buildinh Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN Cf AW truss in with ANSIPI1, for handling, installation bracing trussesA this drawing conformance or shipping, and of seal on or listing this drawing indicates acceptance of pro essiona engineering responsibility solely for the design shown. drawing, cover page .. 6750 Forum Drive The suiCabillty Suite 305 and use of this for any structure is the responsibility of the Building Designer per ANSIIrPI 1 Sec.2. For more information see this'ob's general notes page and these web sites: ALPINE: w .al rneitw.wrn; TPI: www.t inst.or ; SBCA: w .sbcindust xom; ICC: www.iccsafe.org Orlando FL, 32821 SEQN: 103385 / HIPS Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T6 / FROM: RWM Qty: 1 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.09299 Truss Label: A6 / YK 08/05/2020 6'4"10 10'6" 20' 29'6" 33'7"6 40' r 6'410 '} 4'1"6 9'6" '} 9'6" Vl' 6 '} 6'4"10 p 5 T2 =6X6 T3 =5X5 E F 12 T 5 2X4 C 2X4 T (a) W4 (a) W G � W3 v B A - ro H I I�8,8" 1 =4X6(A2) =6X6 =5X8 -6X6 =4X6(A2) 40' 1' I 10' 10' 10' i' 10 1' r 10' } 20' {' 30' 40' '+ Loading Criteria (pso Wind Criteria Snow Criteria (Pg,Pr In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.295 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.547 E 870 240 B 1558 /- /- /907 /728 /196 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.083 J - - H 1558 /- /- 1907 /728 /- Des'Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.154 J Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height: 15.00 ft Code / Misc Criteria Creep Factor: 2.0 TCDL: 4.2 psi B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 sf Bldg Code: FBC 2017 RES Max TC CSI: 0.634 p H Br Width = 8.0 Min Re 1. 9 q= 8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.918 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0:926 Members not listed have forces less than 375# Loc. from endwall: not in 13.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 1933 -3204 E - F 2185 -3486 C - D 1814 - 2950 F - G 1814 - 2950 Top chord 2x4 SP #2 N D - E 2185 - 3486 G - H 1933 - 3204 :T2, T3 2x4 SP 2400f-2.0E: Bot chord 2x4 SP #1 Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) :W3, W4, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Bracing B - L 2898 -1664 K - J 2653 -1464 (a) 1 X4 #3SRB or better continuous lateral restraint L - K 2653 -1439 J - H 2898 -1688 to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be Maximum Web Forces Per Ply (Ibs) supplied andattached ends to a suitable d�, "A, ^ Webs Tens.Comp. Webs Tens. Comp. support by erection contractor. t♦ scab reinforcement may m ♦ ♦ ♦r rip (a) used in lieu) CLR 0 Q e � r ® % �� �I� L - D 466 -153 K - F 918 - 566 D - K 918 -566 F - J 466 -153 r (1 restraint. substitute (1) scab for (1) CLR and (2)®� 0 �`CEr Y �� for CLR'S Scab • E - K 455 -575 scabs (2) where shown. ♦ v reinto be same size, species, grade, and A C a No Vnforcement 80 /o length of web member. Attach with 0.128x3" gun m 1 t tt o nails @ 6" oc. o m Wind o • o Q:, Wind loads based on MWFRS with additional C&C v ♦ STATE ATE Or ��/, member design. s �1 a 0 ♦ s a � C) Additional Notes ® ��1♦ ® R eea ® p Refer to General Notes for additional information ®®O u S !!!!l /CO) (♦ jspp p � ►®p (rid 0 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 `*WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component Safety. Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracinc] installed per BCSI sections B3, B7 or 810, _ as applicable. Apply Iates to each face, oftrussand position as shown above and on the Join Details; unless noted otherwise. kefer to drawings 160A-Z for s�andard plate positions. ALPINE� Alpine, a division of ITW BuildincLComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the mmrcwM truss in ANSI/TPI 1, for handling, installation bracing trussesA this drawing conformance with or shipping, and of seal on or listing this drawing indicates acceptance of pro esstona engineering responsibility solely for the design shown. cover page, , 6750 Forum Drive The suitability Suite 305 and use of this drawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2: For more information see this job's general notes page and these web sites: ALPINE: w .al ineitw.wm; TPI: www.t inst.or ; SBCA:—.sbcindust .com; ICC: www.icceafe.or Orlando FL, 32821 SEQN:1033761 HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef;1WXK89750083T25 % FROM: RWM Qty: 1 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07037 Truss Label: A6A / YK 08/05/2020 "1020' 29'6" 40 ' T3"6i I 4'1'% T 9'6" 4176 106'44"1100 "69'6" :5DX5 T2 =8E8 T3 =6F6 T ,2 5 � �2X4 C 02X4 rn (a) W4 (a) W G o W3 B 133 A - H n l 8'8" 3X6(A1) =5X5 =8X8 B3 =5X5 4 =3X6(At) 40' 10' 10, 10, 10 1 10' 20' 30' 40' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.106 L 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.197 L 999 240 B 1094 /- /- /702 /513 /196 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.026 C - - H* 202 /- /- /113 /94 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.049 C Wind reactions based on MWFRS Mean Height: 15.00 ft Code / Misc Criteria CreepFactor: 2.0 NCBCLL:10.00 TCDL:4.2 sf B Br Width = 8.0 Min Re 1.5 9 q Soffit: 0.00 BCDL: 5.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.845 H Brg Width = 120 Min Req = - Load Duration: 1.25 TPI Sid: 2014 Max BC CSI: 0.828 MWFRS Parallel Dist: h/2 to h Bearings B & J are a rigid surface. Bearings B & J require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0.682 Members not listed have forces less than 375# Loc. from endwall: not in 6.50 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 1259 -2045 E - F 982 -1413 C - D 1132 -1779 F - G 721 - 348 Top chord 2x4 SP #2 N D - E 982 -1413 G - H 474 -179 :T2, T3 2x4 SP #1: Bot chord 2x4 SP #1 :133, B4 2x4 SP #2 N: Maximum Sot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Chords Tens. Comp. :W3, W4, W5 2x4 SP #2 N: B - L 1834 -1045 K - J 440 - 475 Bracing L - K 1566 -806 J - H 287 -391 (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun ). Restraintbe nailssuppled t A���s Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. tt alal ��,wi and attached ends suitable `1*do f ' 7 1 {� r L - D 488 -614 F - J 39 --403 �� p support by re ction contractor.reinforcement �,�c � 1� o �iI _ 0 E - K 488 - 614 J - G 363 403 363 (a) or scab may be used in lieu of CLR sa `^ , Q V C• f f al�1 A., K - F 2080 -1260 restraint. substitute (1) scab for (1) CLR and (2) w0 • •• scabs for (2) CLR'S where shown. Scab a'i • o to be d. 66367 reinforcement same size, species, grade, and I Y 80% length of web member. Attach with 0.128x3" gun a m • Q nails @ 6" oc. R � p Wind �"D • • ++ `ETA I*tom E of°- Ll g Wind loads based on MWFRS with additional C&C STATE member design. ® o g ®s • b� ��'s Additional Notes "'a4i�� ht� FS• s o • ®0 07ve- Refer to General Notes for additional information ION A� FLo REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oYherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a pro erly �10, attached nqid ceiling Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections _ B3, B7 or kefer as applicable. Appty plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. drawings 160A-Z far standard plate positions. to ALPINE A LLPPII NN Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure truss in conformance with ANSIPI1, for handling, shipping, installation and bracing of trussesA seal on this drawing to build the wawca *u cover, or or listing this drawing indicates acceptance of ro-fessionar engineer noy responsibility solely for the design shown. Q�awing page , , 6750 Forum Drive The uitability Suite For and use of this for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: —.al ineitw.mm; TPI: www.t inst.or ; SBCA:—sbcindust .com; ICC: —kcsafe.org Orlando FL, 32821 SEQN: 103394 / HIPS Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK89750083 T2 I FROM:RWM Qty: 1 7A5,175EA,RF01/1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07287 Truss Label: A7 / YK 08/05/2020 8'6" 166" 23'6" 31'6" 40' 8'6" 8' 7' 8' 8'6" 12 s5C5 T2 =5XD5 =4E4 T3 =5F5 T 5 T 9) (a) (a) o_ I ih Bf::2 Xf A io G "a H +8,8" 1 =4X6(A2) -5X8 =6X6 =5X8=4X6(A2) 40' 10' i 10, 10, T 10' 20' 30' +1 4100' Loading Criteria (psg Wind Criteria Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.400 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.742 J 641 240 B 1559 /- /- /891 /730 /164 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.103 1 - - G 1558 /- /- /891 /730 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.190 1 Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height: 15.00 it Code / Misc Criteria Creep Factor. 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.949 G Br Width = 8.0 Min Re 1.8 9 q = Load Duration: 1.25 TPI Std: 2014 Max BC CSI: 0.979 MWFRS Parallel Dist: h/2 to h Bearings B & G are i rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0.344 Members not listed have forces less than 375# 00 FT/RT:20/10 Loc. from endwall: not in 6.50 ft () () Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 1886 -3140 E - F 1967 -3126 C - D 1967 - 3126 F - G 1886 - 3140 Top chord 2x4 SP #1 D - E 2510 -4128 :T2, T3 2x4 SP #2 N: Bot chord 2x4 SP #1 Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Bracing B - K 2296 -2296 J - I -1618 (a) 1X4 #3SRB or better continuous lateral restraint 4033 2826 K - J 4033 - 2296 I - G 2826 -1618 to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable by Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. support erection contractor. tad��011��„,�((,��P�►fhj (a) or scab reinforcement may be used in lieu of CLR A�/+ �ON r' ►Y An A®� restrascabslnt. substitute CLR and (2) e o �po� e / �°p�� C - K 776 -366 E - 1 676 -1039 �4J i + for (2) CLR'S where shoscab wn�S b K - D 673 -1036 I - F 776 -367 ,Am4 Ys� reinforcement to be same size, species, grade, and „�+ +0 �`V�f 80% length of web member. Attach with 0.128x3" gun a 6" d No.86367 nails @ oc. .�, / o Wind a �� Wind loads based on MWFRS with additional C&C ' a a n- memberdesign. p p ® STATE OF G goy Additional Notes r ds Refer to General Notes for additional information or ✓sOAa�ff�loNAa 0 FL REG# 278, Yconhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition Component Safety. for of BCSI (Building Information, byV TPI ani SBCA) safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a pro erly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracingq insTalled per BCSI sections B3, 87 or �10, _ as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. drawings 160A-Z for standard plate positions. f7efer to ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure truss in conformance with ANSI/TPI PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or to build the *xawcw,un cover page , , 6750 Forum Drive listing this drawing indicates acceptance of pro7essronaf engineerin responsibility solely for the design shown. The sui ability Suite 305 Building and use of this drawing for any structure is the responsibility of the Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: w .al ineilw.com; TPI: www.l insl.or ; SBCA: w .sbdndusl xom; ICC: ­Accsafe.org Orlando FL, 32821 SECiN: 103392 / HIPS Ply: 1 Job Number: N372962 975 JRef:1WXK89750083 T22 FROM: RWM City: 1 ,7A5 ,175EA ,RF01 / 1756JEASTHAM/EXPRESS FD-N 218.20.1558.09159 Truss Label: A7A YK 08/05/2020 16'6" 23'6" 31'6" 40' 8' 7' + 8' 12 -5C8 =5p5 =4E6 T3 =5F5 T 5� T (a) �T4 B_--- G `I> T M1 A H 1 8'8" 3X6(A1) =5X5 =-6X6 =6X6 B4=3X6(A1) 30'4" 9'8" 10' 10, 10' 10' 1 10' 20' 30' 40' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.110 D 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.199 D 999 240 B 1055 /- /- /646 /502 /164 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.031 1 - - 1 2029 /- /- /988 /918 !- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.057 I - - G 279 1-244 /- /189 1173 /- NCBCLL: 10.00 Mean Height: 15.00 It Code / Misc Criteria Creep Factor. 2.0 Wind reactions based on MWFRS TCDL: 4.2 psf B Br Width = 8.0 Min Re 1. Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.809 g q = 5 Load Duration: 1.25 TPI Sid: 2014 Max BC CSI: 0.833 1 Brg Width = 8.0 Min Req = 1.5 MWFRS Parallel Dist: h/2 to h G Brg Width = 8.0 Min Req = 1.5 Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: Yes Max Web CSI: 0.724 Bearings B, I, & G are a rigid surface. Loc. from endwall: not in 6.50 ft FT/RT:20(0)/10(0) Bearings B, I, & G require a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Maximum Top Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP #2 N B - C 1159 -1875 E - F 1197 -531 :T3 2x4 SP #1: C - D 1177 -1753 F - G 1051 -451 'T4 2x4 SP 2400f-2.0E: D - E 911 -1350 Bot chord 2x4 SP #1 :B4 2x4 SP 2400f-2.0E: Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Bracing (a) 1X4 #3SRB or better continuous lateral restraint B - K 1662 -924 J - 1 790 -420 to be equally spaced. Attach with (2) 8d Box or Gun K - J 1736 -961 I - G 572 -945 13"x2.5",min.). Restraintto be 4� °>p supplied pled and attached at oth ends to a suitable i Q� s /� Maximum Web Forces Per Ply (Ibs) support by erection contractor.i� �0 0� e /A_ 10,�, Webs Tens.Comp. Webs Tens. Comp. (a) or scab reinforcement may be used in lieu of CLR + C - K 380 -65 E - I 1349 -2185 restraint. substitute (1) scab for (1) CLR and (2) y+ a pe At scabs for (2) CLR'S where shown. Scab 4 a I Y o $� a D - J 397 -568 I - F 542 - 786 reinforcement to be same size, species, grade, and a m o J - E 825 -378 80% length of web member. Attach with 0.128x3" gun o 1 ®y nails @ 6" oc. s ® o ,q STATE OF Wind Wind loads based on MW FRS with additional C&C i ®fie p� � gy Z4 ��~ member design. �+` 0 C QiSjvT® ✓W e e Additional Notes "S e o 0 °°0si Refer to General Notes for additional information e®i mi l { k Negative reaction(s) of -244# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 -WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg, handlin shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI anr7 an fog sa�ety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a proLer y attached ri id ceiling Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 810, _ Apply to face the Join Details, Refer as applicabge. plates each ofPtruss and position as shown above and on unless noted otherwise. to ALPINE drawings 160A-Z for standA LLard plate positions. PP�I NN Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in ANSI/TPI 1, for handling, bracing drawing conformance with or shipping, Installation and of trussesA seal on this or cover page, , 6750 Forum Drive listing this drawing indicates acceptance of engineering responsibility solely for the design shown. The sui abrltty For professional Suite and use of this gnawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wrn; TPI: www.l inst.or ; SBCA: www.sbdndust xom; ICC: w Accsafe.org Orlando FL, 32821 is SEQN: 1034041 HIPS Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK89750083 T7 / FROM: RWM City: 1 7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.09018 Truss Label: A8 ! YK 08/05/2020 6'6" 20' 26'9" 33'6" 40' r T i' 1 " 6'6" 6 9, 6 9 6 9„ 6�9„ 6'6" 5 12 1116C8 =4XD4 T2 =8E8 =4F4 T3 /116X8 G T T o - B H O h 1�fA =4X6(A1) = 8X8 = 8X8 = 8X8=4X6(A1) 40' 10' 10, 10, 10 +1. + + 10' 20' 30, 40' Loading Criteria (pso Wind Criteria Snow Criteria (Pg,Pf In P5F) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.378 E 999' 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.701 E 679 240 M 1558 /- /- /871 /730 /133 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1558 /- P /871 1730 /- EXP: C Kzt: NA HORZ(TL): 0.120 J - - Wind reactions based on MWFRS Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 Code / Misc Criteria Creep Factor: 2.0 M Brg Width = 8.0 Min Req = 1.5 TCDL: 4.2 psf H Br Width = 8.0 Min Re 1.5 Soffit: 0.00 BCDL: 5.0 sf Bldg Code: FBC 2017 RES Max TC CSI: 0.483 g q = P Bearings M & H are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.326 Bearings M & H require a seat plate. Spacing: 24.0 " C&C Dist a: 4.00 it Rep Fac: Yes Max Web CSI: 0.576 Members not listed have forces less than 375# Loc. from endwall: not in 6.50 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 2022 -3308 E - F 3444 -5756 C - D 2557 - 4225 F - G 2556 - 4225 Top chord 2x4 SP #2 N D - E 3444 -5756 G - H 2O22 -3308 :T2, T3 2x6 SP 2400f-2.0E: Bot chord 2x6 SP 2400f-2.0E Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. Wind B - L 3013 -1738 K - J 5069 -2923 Wind loads based on MW FRS with additional C&C L - K 5069 -2928 J - H 3013 -1762 member design. Additional Notes �11lip�®p Maximum Web Forces Per Ply (Ibs) owl Refer to General Notes for additional information Ow, 4WA L /�,�0 Webs Tens.Comp. Tens. Comp. {� 99 IWebs ,%xj" ue �iltl AA. `�` 3tr L - D 736 -1081 F - J 736 -1081 4 ro (�'y D - K 736 - 367 J - G 1513 - 799 ^^'� 9 No. 8636 a, o e v® STATE OFro aA�a'OIV �v► V(pla ► �� FL PEG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building shipping, Component Safety. Information, byy TPI an SBCA) for sa practices pnor to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections B3, B7 or 610, 41611111 as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to drawings 160A-Z for standard plate positions. ALPINE� Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the wnwco vu truss in ANSI/TPI 1, for handling, bracing trussesA on this drawing or cover conformance with or shipping, Installation and of seal pa �e ability6750 Forum Drive listing this drawing indicates acceptance of pro essiona engineer'Ing responsibility solely for the design shown. The sui ability Suite For and use of this drawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wrn; TPI: www.l inst.or ; SBCA: www.sbcindust .corn; ICQ ­iccsafe.org Orlando FL, 32821 SEQN: 103382 / HIPS Ply: 1 Job Number: N372962 Cust: R 8975 JRef 1WXK89750083 T18 % FROM: RWM Qty: 1 7A5,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.09408 Truss Label: A8A / YK 08/05/2020 6'6"18'612 24'6"4 33'6" 40' 6'6" 6'3" 5'9"12 5'11"8 8'11"12 6'6" 12 5 C -6C6 —4p4 T2 =8E8 =8 F14 T3 =6X6 G TW (a) yJg (a) T4 B H `�.�8,8• 1 3i A I 4X8(A1) 14X4 =8X8 B2 M =8X8 =6X12 1114X4=4X6(A1) 1 =5X14 30'4" 918.1 6'4"4 6't"4 6'1"4 5'11"8 5'9"12 3'3"12 6'4"4 1� 6'4"4 12'S"8 18'6"12 24'6"4 30'4" 33'7"1 40' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pr 19 PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.288 D 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.539 D 671 240 p 1870 /- /- /- /875 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.056 C - - K 4638 /- P /- /2094 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.105 C - - H - /-544 /- /215/- Mean Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 Wind reactions based on MWFRS P ' Soffit: 0.00 BCDL: 5.0 sf P P Br Width = 8.0 Min Re 2.6 Bldg Code: FBC 2017 RES Max TC CSI: 0.808 9 q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Sid: 2014 Max BC CSI: 0.946 K Brg Width = 8.0 Min Req = 1. H Brg Width = 8.0 Min Req = .5 Spacing: 24.0 " C&C Dist a: 4.00 ft Rep Fac: No Max Web CSI: 0.978 Bearings P, K, & H are a rigid surface. Loc. from endwall: NA FT/RT:20(0)/l0(0) Bearings P, K, & H require a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Maximum Top Chord Forces Per Ply (Ibs) Lumber Additional Notes Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP #2 N Refer to General Notes for additional information B - C 1930 -4221 E - F 1814 -3982 :T2 2x6 SP #2 N: Negative reaction(s) of -544# MAX. from a non -wind C - D 2297 -5044 F - G 4321 -2055 :T3 2x6 SP SS: :T4 2x4 SP #1: load case requires uplift connection. See Maximum D - E 1814 -3982 G - H 2215 -1014 Bot chord 2x6 SP #2 N Reactions. •B2 2x6 SP SS: WARNING! This truss is not symmetric, but its exterior Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 geometry makes erection error more probable. Chords Tens.Comp. Chords Tens. Comp. :W6 2x4 SP #2 N: It is imperative that this truss be installed properly. :W8 2x4 SP 2400f-2.0E: B - O 3858 -1747 L - K 1187 - 631 Bracing 9 1X4 better 1`,,�vl`14f�,tVlll�y�,op N - M 5073 -2338 J - H 901 -2002 w` �,.� 41 �' ®� �� �1�� M - L 1187 -631 (a) #3SRB or continuous lateral restraint %4� ��p to be equally spaced. Attach with (2) 8d Box or Gun>��Q • ;^ wr • o r nails 0.113"x2.5",min.. Restraint material to be Za4' ®® >� V Y,1e to �® Maximum Web Forces Per Ply (Ibs) supplied and attached at both ends to a suitable 4 • • 1_ Webs Tens.Comp. Webs Tens. Comp. support by erection contractor. ` N0 7 • r (a) or scab reinforcement may be used in lieu of CLR a • p O - C 586 95 M - F 3047 -1290 restraint. substitute (1) scab for (1) CLR and (2) ® •'+ C - N 1329 -605 F - K 2938 -6028 scabs for (2) CLR'S where shown. Scab ® • a N - D 376 -276 K - G 1486 -2972 reinforcement to be same size, species, grade, and 80% length 0.128x3" v ^ci • • D - M 574 -1194 G - J 519 -137 o STATE OF 0 a of web member. Attach with gun f E - M 403 -487 •e nails @ 6" oc. �� ® �q�' � �Q•fS.®#1 Loading v be�� hip supports 6-6-0 jacks with no webs. p0'RA sda��ddl Left side jacks have 6-6-0 setback with 0-0-0 cant 0 8 i iy���t+� and 1-0-0 overhang. End jacks have 6-6-0 setback with 0-0-0 cant and 1-0-0 overhang. Right side jacks have 6-6-0 setback with 0-0-0 cant and 1-0-0 overhang. Wind FL REG# 278, Yoonhwak Kim, FL PE #86367 Wind loads and reactions based on MWFRS. 08/05/2020 -WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, byy TPI an SBCA) fo'r safety bracing per BCSI. Unless noted oTherwise,top chord shall practices prior to performing these functions. Installers shall provide temporarryy have properly attached structural sheathin and bottom chord shall have a propperly attached riclid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and as shown above and on the Joint Details, unless noted otherwise. kefer to position drawings 160A-Z for standard plate positions. ALPINE� Alpine, a division of ITW BuildinlComponents Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the .—Co— truss in ANSI/? PI 1, for handling, installation bracing trussesA this drawing cover e conformance with or shipping, and of seal on or pa , , 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability Suite For p gnawing 1 Sec.2.305 and use of this for any structure is e responsibility of the Building Designer per ANSI/TPI .For more information see this job's general notes page and these web sites: ALPINE: w .al ineitw.com; TPI: w .l inst.or ; SBCA: www.sbcindust .com: ICC: w miccsafe.org Orlando FL, 32821 SEQN: 103443 / COMN Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T8 / FROM: RWM Qty: 3 7A5 ,175EA,RFOl / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08410 Truss Label: B1 / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #1 Bot chord 2x4 SP #1 Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 10, 10, H0510 C 20' 10, 10, Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS 29 10, 10, 20' Def11CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.042 E 999, 360 VERT(CL): 0.077 E 999 240 HORZ(LL): 0.019 E - - HORZ(TL): 0.036 E Creep Factor. 2.0 Max TC CSI: 0.761 Max BC CSI: 0.779 Max Web CSI: 0.171 VIEW Ver: 18.02.01A.0205.19 ,t11114fi►ID�y�/ 'IrA WAS i e•s � p No.86367 � e ~� STATE OF ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 809 /- /- /465 /378 /159 D 750 /- /- /404 /340 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 680 -1223 C - D 698 -1223 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-E 1051 -515 E-D 1051 -515 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - E 449 - 62 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlin shipping, installing.and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly )id ceilingp Locations shown for permanent lateral restraint of webs shall have bracincct1 installed per BCSI sections B3, B7 or 610, e. ADDTV plates to each face of truss and position as shown above and on the Join Details. unless noted otherwise. kefer to of 3 use of this drawing for any structure is the responsibility more information see this job's general notes page and these web sites: ALPINE: his drawing,any failure to build the on this drawing or cover page , design shown. The suitabil Leity SBCA: ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:103446! HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef:1WXK89750083T4 / FROM: RWM Qly: 1 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08145 Truss Label: B2 / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 9'6" 9,6„ 97'12 97'12 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 6X6 :6X6 C D 20' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 20' 9'6" 97'12 "4 20' Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.043 G 999 360 VERT(CL): 0.078 G 999 240 HORZ(LL): 0.021 H - - HORZ(TL): 0.039 H Creep Factor: 2.0 Max TC CSI: 0.965 Max BC CSI: 0.697 Max Web CSI: 0.118 VIEW Ver: 18.02.01A.0205.19 `p Q CENS OoOee No.86367 a a m o1m 0 STATE OF zo v t—V.8' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 807 /- /- /468 /377 1165 E 807 !- /- /468 /377 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 E Brg Width = 8.0 Min Req = 1.5 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-C 693-1218 D-E 693 -1218 C-D 717-1050 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 1045 -488 G - E 1044 -492 H - G 1050 - 491 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 387 - 232 G - D 395 - 232 0,01. 60 Rig ,�" S o0®4!D d,`j0`sl�Ai' `�, . FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 -WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) fo'r sa shipping, practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro any attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing ins ailed per BCSI sections 83, B7 or B10, as applicable. Apply places to each face of truss and position as shown above and on the Joint Details, unless no otherwise. F�efer to drawings 160A-Zforstandard plate positions. Alpine, a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI!! PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa?e , . listing this drawing indicates acceptance of pro essiona engineerinq responsibility solely for the design shown. The sui abddy and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.T. ALPINE AN CW AW 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN:103449/ HIPS Ply: 1 Job Number: N372962 Cust:R8975 JRef:1WXK89750083T10 %I FROM:RWM Qty: 1 7A5,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08146 Truss Label: B3 / YK 08/05/2020 7-6" 7'6" 12'6" 5' =4X8 N4X6 C D 20' 7'6" T ,2 5 � rn N M B E a•t A F H G 4X4(A2) =5X5 =4X4=4X4(A2) 20' 77"12 i 4'6"12 7'9"8 1 T 7'7"11 2 12'"f 20' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BOLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.047 H 999 360 Loc R+ / R- / Rh / Rw / U / RL B 807 /- /- /472 /378 /136 Lu: NA Cs: NA VERT(CL): 0.087 H 999 240 Snow Duration: NA HORZ(LL): 0.020 G - - E 807 P /- /472 /378 /- HORZ(TL): 0.037 G Creep Factor: 2.0 Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 Code / Misc Criteria Bldg Code: FBC 2017 RES Max TC CSI: 0.664 E Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.624 Bearings B & E are a rigid surface. Rep Fac: Yes Max Web CSI: 0.094 Bearings B & E require a seat plate. FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 18.02.01A.0205.19 B - C 795 -1309 D - E 794 -1307 WAVE C-D 811 -1156 e No. 86367 0 e � ® ,.,•.�, a "� '" 0 P w STATE OF ®4r;r oraoF �'�®q Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. B - H 1144 - 601 G - E 1143 - 624 H - G 1151 -602 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide tempora r BCSI. Unless noted ®r herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propeXy id ceiling. Locations shown for permanent lateral restraint of webs shall have bracinp installed per BCSI sections B3, B7 or 810, e. AppQv plates to each face of truss and position as shown above and on the Join Details. unless noted otherwise. f7efer to a division of iim 1, or Tor acceptance any structure his drawing,any failure to build the on this drawing or cover pa e Le design shown. The suit9abdrty, ALPINE ._COMP 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103452 / HIPS Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T20 % FROM: RWM Qty: 1 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.09143 Truss Label: B4 / YK 08/05/2020 fi 5'6" + 10, 5'6" 4'6" 14'6" 4W =4X8 III2X4 =4X8 12 C D E 20' 5'6" 5F-_- T B F B13 4 G J I H 1 3X6(A1) 1112X4 =6X6 1112X4 =3X6(A1) 1, I 5'7"12 5'7"12 Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 0.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 It Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Loading #1 hip supports 5-6-0 jacks with no webs Left side jacks have 5-6-0 setback with 0-0-0 cant and 1-0-0 overhang. End jacks have 5-6-0 setback with 0-0-0 cant and 1-0-0 overhang. Right side jacks have 5-6-0 setback with 0-0-0 cant and 1-0-0 overhang. Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information 20' 4'4"4 10' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: Ni Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): WAVE 4'4"4 14'4"4 Deft/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.153 D 999 360 VERT(CL): 0.285 D 82R 240 HORZ(LL): 0.045 H HORZ(TL): 0.083 H Creep Factor: 2.0 Max TC CSI: 0.542 Max BC CSI: 0.793 Max Web CSI: 0.256 VIEW Ver: 18.02.01A.0205.19 *+�1`t1119f1IfNllt,r w P a e No. 86367 m v v � -,B o STATE OF ®4, ;0 � ' ®� 57'12 20' �� 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1323 /- /- P /622 P F 1323 /- /- P /622 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 F Brg Width = 8.0 Min Req = 1.8 Bearings B & F are a rigid surface. Bearings B & F require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1237 - 2702 D - E 1390 - 3063 C - D 1390 - 3063 E - F 1237 - 2702 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 2443 -1102 I - H 2467 -1105 J -1 2467 -1105 H - F 2443 -1102 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - J 377 -41 I - E 672 - 321 C - 1 672 -321 H - E 377 -41 D - I 375 - 461 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byY TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a progeny attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracingq installed per BCSI sections B3, B7 or 810' as applicable. Appigy plates to each face of truss and position as shown above and on the JOinCDetaIIS, unless noted otherwise. F7efer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the Au CMIAar truss in conformance with ANSI TPI 1, or for handlin% shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , 6750 Forum Drive listing this drawing indicates acceptance of Fro) esstonal engineering responsibility solely for the design shown. The suitability Suite For and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: ww Jpinstnrg; sack www.sbcindustry.com: ICC:—Accsafe.org Orlando FL, 32821 a SEQN: 103457 / COMN Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T9 / FROM: RWM Qty: 1 ,7A5,175EA,RF01 / 1756/E4STHAM/EXPRESS DrwNo: 218.20.1558.07100 Truss Label: C1 / YK 08/05/2020 T co M Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 6'8" 6'8„ =4X4 C 13'4" 68 68 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 13'4" 6,$„ 6'8" 13'4" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.017 F 999� 360 VERT(CL): 0.032 F 999, 240 HORZ(LL): 0.007 F - - HORZ(TL): 0.013 F Creep Factor. 2.0 Max TC CSI: 0.398 Max BC CSI: 0.495 Max Web CSI: 0.111 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 556 /- /- /332 /261 /124 D 556 /- /- /332 /261 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 490 - 775 C - D 491 - 775 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 664 - 327 F - D 664 - 327 ,AttjtlIttttllfPpl ipa No. 86367 a 4 PSTATE - ®® STAi E OF ` e 41 ON A ;j4dionlo", 5 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlingshi ping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI an � SBCA) y satPety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro e�y ]id ceilin Locations shown for permanent lateral restraint of webs shall have bracing ins ailed per BCSI sections B3, B7 or �10, le. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to 60A-Z for standard plate positions. of fTPI 1, or for r acceptance any structure failure to build the l or cover pa e n. The sui ability ALPINE AN COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103454 / COMN Ply: 1 Job Number: N372962 Cust: R 8975 JRet 1 WXK89750083 Tt / FROM: RWM Qty: 3 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07209 Truss Label: C1A / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Wind Criteria Wind Std: ASCE 7-10 Speed:160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 It Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 6'8" 6'8" 4X4 C 13'4" 6,8„ 6'8„ 13'4 6�8" 13'4" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.017 E 999' 360 Loc R+ / R- 1 Rh 1 Rw / U / RL Lu: NA Cs: NA VERT(CL): 0.031 E 999 240 B 559 /- /- /331 /263 /112 Snow Duration: NA HORZ(LL): 0.007 E - - D 498 /- /- /270 /224 /- HORZ(TL): 0.014 E Wind reactions based on MWFRS Code / Misc Criteria Creep Factor: 2.0 B Brg Width = 8.0 Min Reg = 1.5 Bldg Code: FBC 2017 RES Max TC CSI: 0.410 D Brg Width = 8.0 Min Reg = 1.5 TPI Std: 2014 Max BC CSI: 0.499 Bearings B & D are a rigid surface. Rep Fac: Yes Max Web CSI: 0.111 Bearings B & D require a seat plate. FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. WAVE VIEW Ver: 18.02.01A.0205.19 B - C 505 - 785 C - D 526 - 784 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - E 673 - 385 E - D 673 - 385 4 d No 86367 e ® A A ®• STATE OF ®_�,� F. 0r NIII BA, , FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI and SBCA) r sa ety practices prior to pertorming these functions. Installers shall provide temporary BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly lid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, le._ Apply plates to each face oftruss and position as shown above and on the JoinCDetails, unless noted otherwise. kefer to a division of rl PI 1, or Tor r acceptance any structure his drawing,any failure to build the on this drawing or cover pa e ie design shown. The suitability ALPINE ♦NOW COWi 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103459 / COMN Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T12 % FROM: RWM Qty: 1 ,7A5,175EA,RF01 / 1756/EASTHANI/EXPRESS DrwNo: 218.20.1558.07536 Truss Label: C2 / YK 08/05/2020 �7'2"5"5 1,0"16 6'1"11 9'3"1 i 1 T4" r 4'0"15 2'0"12 2'0"12 4'0"15 12 3.45 p -4X4 =4X6 D E T 12 \\\ C 6 /// 4F6 rn i- 5 � N 1� n p yt A B G O H t__V18. J I 4X4(A2) =4X4 =3X8-4X4(A2) 1 13'4" 4 _ 4'4"7 4'6" 4'5"9 �.1 4'4"7 8'10"7 13'4" + 1' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 4.08 TC: From 27 plf at 4.08 to 27 plf at 9.25 TC: From 55 plf at 9.25 to 55 plf at 14.33 BC: From 20 plf at 0.00 to 20 plf at 4.08 BC: From 10 plf at 4.08 to 10 plf at 9.25 BC: From 20 plf at 9.25 to 20 plf at 13.33 TC: 73 lb Conc. Load at 4.08, 9.25 TC: 143 lb Conc. Load at 6.14, 7.19 BC: 32 lb Conc. Load at 4.08, 9.25 BC: 64 lb Conc. Load at 6.14, 7.19 Wind Wind loads and reactions based on MW FRS. Additional Notes Refer to General Notes for additional information Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.041 D 999 360 Loc R+ / R- / Rh / Rw / U / RL B 771 /_ /_ /_ /373 /- Lu: NA Cs: NA VERT(CL): 0.075 D 999 240 Snow Duration: NA HORZ(LL): 0.015 1 - - G 771 /- /- P /373 P HORZ(TL): 0.027 1 Creep Factor: 2.0 Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 Code / Misc Criteria Bldg Code: FBC 2017 RES Max TC CSI: 0.222 G Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.547 Bearings B & G are a rigid surface. Rep Fac: Varies by Ld Case Max Web CSI: 0.086 Bearings B & G require a seat plate.Members FT/RT:20(0)/10(0) not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 18.02.01A.0205.19 B - C 635 -1409 E - F 576 -1324 WAVE C - D 579 -1327 F - G 636 -1408 D - E 524 -1129 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 1260 - 554 I - G 1259 - 556 J-1 1121 -524 �,I�t11191ttil , 0 No, 86367 a r q STATE OF,--,- cu�� f 4®, �gNAI a i FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlingshipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propedy aid cei!inq Locations shown for ermanent lateral restraint of webs shall have bracing ins�alled per BCSI sections B3, B7 or B10, le. Appgv plates to each face otptruss and Dosition as shown above and on the Join Details. unless noted otherwise. f7efer to Alpine, a division of truss in conformanc listing this drawinc and use of this c For more information see I I F'I 1, or Tor r acceptance any structure his drawing,any failure to build the on this drawing or cover pa e , to design shown. The sup ebtltty TPI 1 Sec.2. CA: w .sbcmdustryxom; ICC: ww kcsat ALPINE A 00MG Y 6750 Forum Drive Suite 305 Orlando FL, 32821 S SEQN: 101437 / JACK Ply: 1 Job Number: N372962 Cust: R8975 JRef:tWXK89750083 FROM: RWM Qty: 4 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.04089 Truss Label: CJB / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N T10'4"2 0 0 B N A 8rpn (J 2M(A1) 1'0"6 B} 4-0"4 4'0"4 Wind Criteria Wind Sid: ASCE 7-10 Speed:160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpj: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.003 D HORZ(TL): 0.005 D Creep Factor: 2.0 Max TC CSI: 0.245 Max BC CSI: 0.159 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 H WAA, yPp`'0 Ir AA No, 86367 di CC STATE 4F ®4, 0,0 OR I ®0 ®®®® b �ON+A�11 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH'THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, an in shipping, installing. and bracing. Refer to and follow the latest edition of BC SI (Building Component Safety Information, byy TPI and SBCA) toy satety practices prior to performing these functions. Installers shall provide temporarryy bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, 87 or B10, as applicable. Apply lates to each face otptruss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the parrwcon A",. truss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page, , 6750 Forum Drive listing this drawing indicates acceptance of proresslonaf engineering responsibility solely for the design shown. The suitablllty Suite For and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.1305 For more information see this job's general notes page and these web sites: ALPINE: www.alpineihv.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ]CC: www.imsafe.org Orlando FL, 32821 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 223 /- /- /171 /95 /88 D 70 /- /- /53 /9 /- C 91 /- /- /35 /66 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# SEQN: 103356 / MONO Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1=1<89750083 T17 % FROM: RWM Qty: 3 7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08925 Truss Label: J66 / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 III2X4 D 12 5 F77- o_ LO in N ch B i 8'8" FIE 2X4(A1) 1113X6 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes Refer to General Notes for additional information 6' 1 6' 6' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 6'� Defl/CSI Criteria PP Deflection in loc Udetl U# VERT(LL): 0.019 E 999 360 VERT(CL): 0.033 E 999 240 HORZ(LL): 0.010 E - - HORZ(TL): 0.017 E Creep Factor: 2.0 Max TC CSI: 0.427 Max BC CSI: 0.343 Max Web CSI: 0.218 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 291 /- /- /216 /64 /90 F 243 !- /- /155 /85 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 F Brg Width = 8.0 Min Req = 1.5 Bearings B & F are a rigid surface. Bearings B & F require a seat plate. Members not listed have forces less than 375# ®A_g� C'E�(`j'C�`i��7 0.r�l No.86367 a a e � o, STATE OF ® w eroo�/;s�►eo FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlinqg shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byv TPI and SBCA) fc safety practices pnor to performing these functions. Installers shall provide temporarryY bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly attached ri id ceilin Locations shown forpermanent lateral restraint of webs shall have bracinq ins�alled per BCSI sections B3, 67 or 610. as applicable. Apply, plates to each face of truss and position as shown above and on the JoinTDetails, unless noted otherwise. �tefer to drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI/l PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa�e , listing this drawing, indicates acceptance of ppro essiona engineering responsibility solely for the design shown. The sui ability and use of this drawing for any structure is go) responsibility of the Building Designer per ANSIfTPI 1 Sec.2. ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103358 / MONO Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T14 % FROM: RWM Qty: 2 ,7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07630 Truss Label: J66A / YK 08/05/2020 Loading Criteria (psq TCLL: 20.00 TCDL: 7.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 1112X44 C 12 5 o_ N A 8,8„ E D 2X4(A1) 1113X6 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes Refer to General Notes for additional information 6' 6' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 6"_� Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.020 D 999 360 VERT(CL): 0.037 D 999 240 HORZ(LL): 0.010 D - - HORZ(TL): 0.019 D Creep Factor: 2.0 Max TC CSI: 0.447 Max BC CSI: 0.360 Max Web CSI: 0.224 VIEW Ver. 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A 230 /- /- /150 174 /117 E 249 /- /- /161 /146 /- Wind reactions based on MWFRS A Brg Width = 8.0 Min Req = 1.5 E Brg Width = 8.0 Min Req = 1.5 Bearings A & E are a rigid surface. Bearings A & E require a seat plate. Members not listed have forces less than 375# %*o1 IIIIlI I IPNlffA40 ® sp®� a �+./4 A A 4 No.86367 r o 0 'rr - �� STATE OF FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, as applicable. Apply places to each face oftrussand position as shown above and on the Join "Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Alpine. a division of ITW Buildina Components GrouD Inc. shall not be responsible for anv deviation from this drawing,any failure to build the 'l PI 1; or for r acceptance any structure on this drawing or cover pa e ie design shown. The suit9abdrty ALPINE pN OWCOMipxY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 1033451 EJAC Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1WXK89750083 T38 % FROM: RWM Qty: 14 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08644 Truss Label: EJ66 / YK 08/05/2020 Loading Criteria (psf) TOLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N C 11'51 12 5 rn o In Cl) B A L 8'8„ D 2X4(A1) 1 6-6rr 6'6" Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psi MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 It Loc. from endwall: not in 4.50 It GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf., NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.014 D HORZ(TL): 0.025 D Creep Factor: 2.0 Max TC CSI: 0.586 Max BC CSI: 0.444 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 311 /- !- /229 /124 /135 D 117 /- /- /90 /17 /- C 157 /- /- /67 /114 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# d,40i�i1941dlt►/�l 0-`�5(n� rrR�yh�%�'�,,PP No.86367 e GO o 40 �® STATE OF 0Soil 0N(AI e� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shpping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI and SBCA) fo'r sa ety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless noted olherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a propperly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply pplates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to ALPINE!I drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the ANRW COMPAN truss in conformance with ANSI/1 PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page , , 6750 Forum Drive listing this drawing, indicates acceptance of pro essronat engineering responsibility solely for the design shown: The suitability Suite For and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinsl.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org _ Orlando FL, 32821 SEQN: 103348/ EJAC Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK81710013 FROM: RWM Qty: 6 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07411 Truss Label: EJ56 / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SIP #2 N C 11'0"1 12 5 rn u7 N p M B D 2M(A1) �—v sin 66" 5'6" Wind Criteria Snow Criteria (Pg,Pf in PSF) Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: N/ Speed: 160 mph Pf: NA Ce: NA Enclosure: Closed Lu: NA Cs: NA Risk Category: II Snow Duration: NA EXP: C Kzt: NA Mean Height: 15.00 it Code / Misc Criteria BCDL: 4.2 psf BCDL: 5.0 psf Bldg Code: FBC 2017 RES MWFRS Parallel Dist: 0 to h/2 TPI Sid: 2014 C&C Dist a: 3.00 ft Rep Fac: Yes Loc. from endwall: not in 4.50 It FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL VERT(CL): NA HORZ(LL): 0.008 D HORZ(TL): 0.014 D Creep Factor: 2.0 Max TC CSI: 0.450 Max BC CSI: 0.313 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 1I111PIPPf `�,ease, WA A- jr��o,�� a Na, 86367 STATE OF ®�~ o 4 Ir, ®� � t B 274 /- /- /205 /111 /117 D 98 /- /- /75 /14 /- C 131 /- /- /55 /95 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# 0' ;<s *0 ZORIpp" . ,"- 6 FL REG# 278, Yoonhwak Kim, FL PE 486367 08/05/2020 -WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building !Safety Information, by TPI and SBCA) fsafety practices prior to performing these functions. Installers shall provide tempora BCSI. Unless noted oherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propeVr y )1I'd ceiling Locations shown for permanent lateral restraint of webs shall have bracinginstalled per BCSI sections B3, B7 or B10, e. App?y plates to each face of truss and position as shown above and on the Joinf etails, unless noted otherwise. f7efer to 60A-Z for standard plate positions. Alpine, a division of ITW BuildiaComponents Group In truss in conformance with ANSIIi PI 1, or for handlin listing this drawing indicates acceptance of prRes , and use of this gnawing for any structure is phe re! For more information see this job's general notes page and these web his drawing,any failure to build the on this drawing or cover pa e ie design shown. The suit9abdlty ALPINE •.—Comvn"r 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103344 / JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T29 % FROM: RWM Qty: 4 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DnvNo: 218.20.1558.07817 Truss Label: CJS KD / YK 08/05/2020 C 10'9"4 N V 00 (V B N T D Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft . GCpi: 0.18 Wind Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 4' 11 "4 4' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NF Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Deft/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.006 D HORZ(TL): 0.010 D Creep Factor: 2.0 Max TC CSI: 0.373 Max BC CSI: 0.249 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 254 /- P /192 /104 /107 D 88 /- /- /66 /13 P C 116 /- !- /48 /84 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ,���119ftI1► w m a o e m STATE OF r�rA�i{p®�Vil�u'® m �`eaw eea�tirra�►� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlin shl ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) fo'r sa ety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properyy aid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 810, le.- Apply plates to each face, of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to of ' I I'I .1. or Tor r acceptance any structure his drawing;any failure to build the on this drawing or cover paqe re design shown. The su ability TPI 1 SeaZ CA: w .sbcindus*xom; ICC: w .iccsaf AL NE .-Co-- 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103347 / JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1WXK89750083 T34 1 FROM: RWM Qty: 4 ,7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08753 Truss Label: CJ36 / YK 08/05/2020 T Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N 1' 3'5"4 3'5"4 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psf MW FRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCp!: 0.18 Wind Duration: 1.60 Wind Wind loads based on MW FRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "0.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N1 Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.002 D HORZ(TL): 0.003 D Creep Factor: 2.0 Max TC CSI: 0.175 Max BC CSI: 0.117 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 201 /- /- /159 /86 /8C D 59 /- /- /45 /8 /- C 76 /- /- /30 /56 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# !60 maw �g �+����v�''a• ��'di No.86367 m p' • • w a• STATE OF o a O R A� ; 1t 91IIi181111 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) fsafety practices prior to performing these functions. Installers shall provide temporarryy BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a propperly id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, 67 or B10, i a. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to 60A-Z for standard plate positions. of any from this drawing(any failure to build the t seal on this drawing or cover pa e , for the design shown. The suitability ALPINE AN"WCOMDANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 103343 / JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1WXK89750083 T30 % FROM:RWM Qty: 4 ,7A5,175EA,RF01/1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08285 Truss Label: CJ3 / YK 08/05/2020 12 C T9' 11 "4 N 00 B A8ron D V Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA D Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 2' 11 "4 2' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: Ni Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udell U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.194 Max BC CSI: 0.108 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 184 /- /- /148 /81 /70 D 50 /- /- /39 /6 /- C 62 /- /- /23 146 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# 4�4�fii411Pf►rrrrO WA A- hA O� Y`C����+� �P✓9r m No.86367 R ° � ®° STATE OF 0' "'�44(%N Ais e �� ► FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly K. ceiling Locations shown for permanent lateral restraint of webs shall have bracing insta[led. per BCSI sections B3, 67 or 610, K. Apply fates to each face oftruss and position as shown above and on the JoingDetaft, nless no otherwise. f�efer to 60A-Z for s�andard plate positions. Of ,im -i,orrorn acce tance any structure from this drawing;any failure to build the t seal on this drawing or cover pa e ,for the design shown. The suitability ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 1033421 JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T33 % FROM: RWM Qty: 4 7A5,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08831 Truss Label: CA / YK 08/05/2020 12 5 C T Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. a B N T 9' 1 "4 r- ?o OO 81 OO 11 D 2X4(A1) 1, 11 "4 11 "4 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in Icc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(CL): NA Snow Duration: NA HORZ(LL): 0.000 D HORZ(TL): 0.000 D Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 2017 RES Max TC CSI: 0.188 TPI Std: 2014 Max BC CSI: 0.025 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/l0(0) Plate Type(s): VIEW Ver: 18.02.01A.0205.19 WAVE ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 142 /- /- /135 /87 /34 D 10 /-2 /- /19 /12 /- C - /-15 /- /27 /29 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg,Width = 1.5 Min Reg = - C Brg Width = 1.5 Min Reg = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# `I0 6A�A WA fj'0!�%s' w a STATE OF OR FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlingshipping, installing,and bracing. , Refer to and follow the latest edition of BCSI (Building quire Information, byv TPI and SBCA) r sa ety practices poor to pertormmg these functions. Installers shall provide temporary BCSI. Unless noted oiherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro eny Aceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 910, . App?y plates to each face of truss and position as shown above and on the Join f Details, unless noted otherwise. Defer to 60A-Z for standard plate positions. 7PI 1; or for h acceptance any structure his drawing,any failure to build the on this drawing or cover page , Le design shown. The suiFabfltty ALPINE .-COMVANY 6750 Forum Drive Suite 305 Orlando FL, 32821 Z SEQN: 103346 / JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef:1 WXK89750083 T35 % FROM: RWM Qty: 4 7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.07552 Truss Label: CJ16 / YK 08/05/2020 12 5 F,7- C 9'3" 12 B d A 8rCJpn D �— 11 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 1'5114 1'5"4 Snow Criteria (Pg,Pf in PSF) Deft/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA , Lu: NA Cs: NA VERT(CL): NA Snow Duration: NA HORZ(LL): 0.000 D HORZ(TL): 0.000 D Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 2017 RES Max TC CSI: 0.188 TPI Std: 2014 Max BC CSI: 0.026 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 18.02.01A.0205.19 WAVE ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /128 /73 /43 D 20 /- /- 123 /8 /- C 13 /- /- /15 /11 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ,r>!tt\t9f tINDp1�I Irl CENS� e rpp�p N0.86367 a �p ® STATE OF 0.�0� 10P,10P N�AI ` FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI an SBCA) toy safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly iid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 810, e. App y lates to each face oftrussand position as shown above and on the Join f Details, unless noted otherwise. (Refer to 60A-Z for s�andard plate positions. Alpine, a division of ITV truss in conformance w listing this drawing it and use of this drawing, For more information see this any structure IS the responsibility ral notes page and these web sites: ALPINE: TPI: failure to build the 1 or cover papa n. The suigability ALPINE ANRWCOMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 101443 / JACK Ply: 1 Job Number: N372962 Cust: R 8975 JRef1wXK89750083 T26 / FROM: RWM Q, 2 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.04091 Truss Label: CJA / YK 08/05/2020 C 12 10'6" 5 20 N t;p B --.� N J� A 8'8n D 2X4(A1) Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 4'3"9 4'3'9 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(CL): NA Snow Duration: NA HORZ(LL): 0.004 D HORZ(TL): 0.006 D Code / Misc Criteria Creep Factor. 2.0 Bldg Code: FBC 2017 RES Max TC CSI: 0.286 TPI Std: 2014 Max BC CSI: 0.185 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 18.02.01A.0205.19 WAVE ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 231 /- /- /177 /97 /95 D 76 /- /- /56 /11 A C 99 /- P /41 /72 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# .`,Ay11111111l1i►vv,®�i p 4 ®' No. 86367 STATE DE V. 0 ;�®LORIp44�t, r �,b ®�6�4Sd 10NA� ! FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing. and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) fsa�ety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted oyherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly 51I'd ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, 87 or B10, e. Apply plates to each face oftrussand position as shown above and on the JoiNest'!Is, unless noted otherwise. f7efer to 60A-Z for standard plate positions. Alpine, a division of truss in conformanc listing this drawinc and use of this 2 For more information see t rt 1, or Tor r acceptance any structure his drawing;any failure to build the on this drawing or cover pa e re design shown. The suaZbility TP11 Sec.2. CA: www.sbcmdustry.com; ]CC: www.iccsaf ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 1033541 HIP_ Ply: 1 Job Number: N372962 Cust: R8975 JRef'.1WXK89750083 T16 ! FROM: RWM Qty: 2 7A5 ,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08472 Truss Label: HJ66 / YK 08/05/2020 T Q1 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber 1'5" Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP #2 N Bot chord 2x4 SP 2400f-2.0E Webs 2x4 SP #3 Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac.=1.25) TC: From 0 plf at -1.41 to 55 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 9.07 BC: From 2 plf at 0.00 to 2 plf at 9.07 TC: -2 lb Conc. Load at 1.37 TC: 124 lb Conc. Load at 4.20 TC: 232 lb Conc. Load at 7.03 BC: 20 lb Conc. Load at 1.37 BC: 99 lb Conc. Load at 4.20 BC: 175 lb Conc. Load at 7.03 Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information Provide (3) 16d common 0.162"x3.5", toe -nails at TC. Provide (3) 16d common 0.162"x3.5", toe -nails at BC. 4'8"12 4'8"12 8'5"2 8'5"2 Snow Criteria (Pg,Pr in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE 9'0"13 4'4"l 0 7711� 9'0"13 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.035 F 999, 360 VERT(CL): 0.062 F 999 240 HORZ(LL): 0.009 F - - - HORZ(TL): 0.021 F Creep Factor: 2.0 Max TC CSI: 0.537 Max BC CSI: 0.530 Max Web CSI: 0.224 VIEW Ver: 18.02.01A.0205.19 yrit;ll a 91 i IIIP>'p�� CENS w No. 86367 s p ® 4 m STATE OF w T + 11'4"7 N O M ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 290 /- /- /- /186 /- E 338 /- /0 /- /121 /0 D 95 /- /- /- /66 P Wind reactions based on MWFRS B Brg Width = 11.3 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 337 - 531 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-F 528 -315 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 335 - 560 ' ��)JipciV®4- d�S �® f o+ j W1� i FL REG# 278, Yoonhwak Kim, FL PE #86367 09/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS, Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary _ bracing per BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have brjeo nq installed per BCSI sections B3, B7 or 610, as applicabgle. Apply plates to each face oftrussand position as shown above and on the JoinCDetails, unless noted otherwise. F�efer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the a""wco-W truss in conformance with ANSIITPI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page , , 6750 Forum Drive listing this drawing indicates acceptance of pro-fessionaT engineering responsibility solely for the design shown. The sui ability Suite For and use of this drawing, for any structure is the responsibility of the Building Designer per ANSI1TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitmcom; TPI: www.t inst.or ; SBCA: www.sbcindust .cam; [CC: www.iccsafe.orq Orlando FL, 32821 SEQN: 103352 / HIP_ Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK89750083 T39 % FROM: RWM City: 2 ,7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.08675 Truss Label: HJ56 / YK 08/05/2020 C 12 1011"13 3.54 ti N N O B y n +8'8�� D 1'5"12 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Special Loads 2X4(A1) Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 ----(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25) TC: From 0 plf at -1.48 to 55 plf at 0.00 TC: From 2 plf at 0.00 to 2 plf at 7.72 BC: From 2 plf at 0.00 to 2 plf at 7.72 TC: 26 lb Conc. Load at 2.08 TC: 152 lb Conc. Load at 4.91 BC: 40 lb Conc. Load at 2.08 BC: 118 lb Conc. Load at 4.91 Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 7'8"9 7'8"9 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N1 Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.018 D HORZ(TL): 0.036 D Creep Factor: 2.0 Max TC CSI: 0.885 Max BC CSI: 0.756 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 239 /- /- /- /95 /- D 137 /- P /- /14 P C 106 P P P /57 /- Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# No,;® AH WAk No. 86367 R e STATE OF ° 4r�4 NA1.�o gaa�(��s►io FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS' quire extreme care in fabricating, handling, shipping, installing.and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI and SBCA) for sa ety practices prior to performing these functions. Installers shall provide tempora r BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathingp and bottom chord shall have a proppeerly aid ceiling Locations shown for permanent lateral restraint of webs shall have bracingq inslalled per BCSI sections B3, B7 or B10, r e. Apply plates to each face of truss and position as shown above and on the Jo Netalls, unless noted otherwise. Refer to 60A-Z for standard plate positions. of fl PI 1, or for h acceptance any structure from this drawing,any failure to build the t seal on this drawing or cover pa e _for the design shown. The suit9abdrty ALPINE ANnWCO-. 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 101450 / HIP_ Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK89750083 T32 FROM: RWM Qty: 2 ,7A5,175EA,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.04090 Truss Label: HJA / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SIP #2 N C 10'11"15 12 4.56 (� n N CV O M B A 8-8„ D 2X4(A1) 1T'3 "1 6' "1 6'0"1 0I Wind Criteria Wind Sid: ASCE 7-10 Speed:160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Loading Hipjack supports 4-2-15 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf In PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.007 D HORZ(TL): 0.014 D Creep Factor: 2.0 Max TC CSI: 0.438 Max BC CSI: 0.264 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ,N01%AJ111111HI)�/ ONMH'AA- No .86367 m •' v a STATE OF y� 40RIVty e ®s S 000 bo N'A1 t� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/05/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, byv TPI and SBCA) fo'r saty practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, as applicable. Apply lates to each face oftrussand position as shown above and on the JoinCDetails, unless no otherwise. f�efer to A LPI N E drawings 160A-Z for s�andard plate positions. Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ,��E,,,,,, truss in conformance with ANSI gPI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page, . 6750 Forum Drive listing this drawing indicates acceptance of pro) essional engineering responsibility solely for the design shown. The suitability and use of this drawing, for any structure is the responsibility of the building Designer per ANSI1TPI 1 Sec.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wm: TPI: www.l inswr ; SBCA: www.sbcindusl .com; ICC: www.i=afe.org Orlando FL, 32821 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 128 /- /- /- /62 /- D 64 /- /- /14 /- /- C 143 /- /- /- /107 /- Wind reactions based on MWFRS B Brg Width = 8.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# SEQN: 101451 / HIP_ Ply: 1 Job Number: N372962 Cust: R8975 JRef:1WXK89750083 T11 I FROM: RWM Qty: 2 7A5 ,175EA ,RF01 / 1756/EASTHAM/EXPRESS DrwNo: 218.20.1558.03901 Truss Label: HJB / YK 08/05/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N 12 10'4"13 4.56 o - N � B N A 8'8" D 2X4(A1) �- 1'1 "3 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: NA GCp!: 0.18 Wind Duration: 1.60 Loading Hipjack supports 3-1-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord 4'5"6 4'5"6 Snow Criteria (Pg,Pf In PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg. Code: FBC 2017 RES TPI Sid: 2014 Rep Fac: No FURT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.002 D HORZ(TL): 0.003 D Creep Factor: 2.0 Max TC CSI: 0.148 Max BC CSI: 0.088 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 95 /- P /- /50 /- D 32 /- /- /9 /- P C 73 /- /- P /55 P Wind reactions based on MWFRS B Brg Width = 8.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# foe ® e No.86367 to e 0 R 9 E o 0 j� STATE OF o w� °so�� ®®� ORioT®� �o S ®• 0®m® b FL REG# 278, Yoonhwak Kim, FL PE 486367 08/05/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling,shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices poor to performing these functions. Installers shall provide tempora bracing per BCSI. Unless noted oyherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly It., ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or t310, as applicable. Apply lates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to drawings 160A-Z for s�andard plate positions. Alpine, a division of ITW Buildina Comoonents Grouo Inc. shall not be resnonsible for anv deviation from this drawing any failure to build the any on this drawing or cover pa e re design shown. The su! ability ALPINE 6750 Forum Drive Suite 305 Orlando FL, 32821 TRULOX INFORMATION DETAIL DO NOT APPLY NAILS WITHIN 1/2" OF LUMBER TYPICAL PANEL POINT WITHOUT SPLICE EDGES OR 1" OF LUMBER ENDS ON EACH FACE, 1/2" AS SHOWN BY DASHED LINES. 1/2 1 r -� r1/2" 1/2" NAILS MUST NOT SPLIT LUMBER. — C—zl 1/2"1/2„Ei 1„ —r TYPICAL FILLER 1 /2 - 1/2„ 1/2 n 2- PLATE AS 1/2' 1/2" HEEL ` / / � \ SPECIFIED \ \ / 1/2" \ TYPICAL OFF PANEL SPLICE H J L ON SEALED DESIGN 1/2" n TYPICAL PANEL POINT SPLICE 1/2 -1--' 1„ n 1/2" n 'r 1 rt1/1/ 2!"} 1" 1/2" n n TRULOX PLATE y\��,� N NA;� �'Oi— �4J®' �GEN,�S�. APPLIED OVER �q4 . j, jP r ® No, Q63 OTHER PLATES, j v 6 O 1/2" • n d ® ... 1 --T n 1/2" 1/2" 1/2" STATE OF NOTES:�(�*Ll TRULOX PLATING PER PLY�AS SPECIF ED ONE REQUIRED MTHE BER OSEALED DESIGN 7REFER� ING TH S DETAIL. OR EQUAL, PER FACE oO U ON b j0 -10 LOCATES PLATE CORNER OR FLUSH EDGE.J��(�1'4� 1 ALPINE ❑ LOCATES PLATE CENTER. TL AN ITW COMPANY 514 Earth City Expressway suit.242 Earth City, MO 63045 RWm , Yoonhwak Kim, FL PE #86367 PAGE 1 OF 1 DATE 10/01/14 t. e 10, Gable Stud Reinf orcement Detail ASCE 7-101 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Or, 120 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Or: 120 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or: 100 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure D, Kzt = 1.00 S 2"Brace Gable Vertical pacing Species Grade No Braces (1) ix4 'L' Brace Al (1) 2x4 'L' Brace to(2) 2x4 'L' Brace ww (1) 2x6 'L' Brace If (2) 2x6 'L' Brace ■ Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B ^ r— #1 #2 ' , U S # 3 4' 1' 6' 7' 7' 1' 8' 6' 8' 10, 10, 1' 10, 6' 13' 4' 13' 1 0' 14' 0' 14' 0' H F Stud 4' 1' 6' 7' 7' 0' 8' 6' 8' 10, 10, 1' 10' 6' 13' 4' 13' 10' 14' 0' 14' 0' O Standard 4' 1' 5' 8' 6' 0' 7' 7' 8' 1' 10, 1' 10' 6' ill 10, 12, 8' 14' 0' 14' 0' #1 4' 6' 7' 4' 7' 8' 8' 8' 9' 0' 10' 4' 10, 9' 13' 8' 14' 0' 14' 0' 14' 0' S P #2 4' 3' 7' 3' 7' 7' 8' 7' 8' 11' 10' 3' 10' B' 13' 6' 14' 0' 14' 0' 14' 0' #3 4' 2' 6' 0' 6' 4' 7' 11' 8' 6' 10' 2' ID' 7' 12' 5' 13' 4' 14' 0' P Stud 4' 2' 6' 0' 6' 4' 7' I1' 8' 6' 10' 2' 10' 7' 12' 5' 13' 4' 14' 0' 14' 0' Standard 4' 0' 5' 3' 5' 7' 7' 0' 7' 6' 9' 6' 10, 2' 11' 0' ill 10, 14' 0' 14' 0' U #1 / 02 4' 11' 8' 4' 8' 8' 9' 10' 10' 3' ill 8' 12' 2' 14' 0' 14' 0' 14' 0' 14' 0' _P S P P #3 4' 8' 8' 1' a' 8' 9' 8' 10, 1' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' U LJ HP Stud 4' 8' 8' 1' 8' 6' 9' 8' 10, 1' 11' 7' 12' V 14' 0' 14' 0' 14' 0' 14' 0' O Standard 4' 8' 6' 11' 7' 5' 9' 3' 9' 11' 11' 7' 12' V 14' 0' 14' 0' 14' 0' 14' 0' #1 5' 1' 8' 5' a, 9' 9' 11' 10' 4' 11' 10' 12' 4' 14' 0' 14' 0' 14' 0' 14' 0' / S P #2 4' 11' 8' 4' a, 8' 9' 10, 10131 11' 8' 12' 2' 14' 0' 14' 0' 14' 0' 14' 0' `2 #3 4' 9' 7' 4' 7' 9' 9' 9' 10' 2' 11' 8' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' Q� D P L Stud 4' 9' 7' 4' 7' 9' 9' 9' 10' 2' 11' 8' 12, 1' 14' 0' 14, 0' 14' 0' 14' 0' Standard 4' 8' 1 6' 5' 6' 10, 8' 7' 9' 2' 11' 7' 12' 1' 1 13' 6' 14' 0' 14' 0' #1 / #2 5' 5' 1 9' 2' 9' 6' 1 10' 10' 11' 3' 11' 8' 13' 5' 14' 0' 14' 0' 14' V 14' 0' d S P P #3 5' 1' 9' 0' 9' 4' 10, 8' 11' 1' 12' 9' 13' 3' 14' 0' 14' 0' 14' 0' 14' 0' U LJ P Stud 5' 1' 9' 0' 9' 4' 10, 8' 11' 1' 12' 9' 13' 3' 14' 0' 14' 0' 14' 0' 14' 0' U I� Standard 5' 1' 8' 0' S' 6' 10, 8' 11' 1' 12, 9' 13' 3' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 8' 9' 3' 9' 8' 10, ill 11' 4' 13, 0' 13' 6' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 5' 5' 9' 2' 9' 6' 10, 10, 11' 3' 12' 11' 13' 5' 14' 0' 14' 0' 14' 0' 14' 0' 11 0-1 #3 5' 3' 8' 5' 9' 0' 10' v-1 11' 2' 1 12' 10'1 13' 4' 14' 0' 14' 0' 14' 0' 14' 0' r—I D F L Stud 5' 3' 8' S' 9' 0' 10' 9' 11' 2' 12' 10' 13' 4' 14' 0' 14' 0' 14' 0' 14' 0' Standard 5' 1' 7' 5' 7' 11'1 9' 11' 1 10' 7' 1 12' 9' 1 13' 3' 14' 0' 14' 0' 14' 0' 1 14' 0' Bracing Group Species and Gradesi Group AI S ruce-Pine-Fir Hem -Fir #1 / #2 Standard #2 Stud #3 Stud #3 Standard Dou lns Flr-Lurch Southern Pinewww #3 #3 Stud otudStandard Stndard Group B: Hem -Fir #1 4 Btr #1 Dou las Fir -Larch Southern Plnewww #1 #1 q2 q2 lx4 Braces shall be SRB (Stress -Rated Board), wwFor Ix4 So, Pine use only Industrinl 55 or Industrial 45 Stress -Rated Boards, Group B 11 values maybe used with these rndes. Liable I russ Detail Notes: Wind Load deflection criterion Is L/240, Provide uplift connections for 55 plf over continuous bearing (5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. About j'� Attach 'L' braces with 10d (0.128'x3,0' min) nails, able Truss X For (1) 'L' brace, space nails at 2' o.c. In 18' end zones and 4' o.c, between zones. Diagonal brace option )K)KFor (2) 'L' braces. space nails at 3' o.c. vertical length may be T In 18' end zones and 6' o,c, between zones. doubled when diagonal 18' X 'L' bracing must be a minimum of 80% of web brace Is used. Connect diagonal brace for 450# •L• 1!�_rP1.e1 // member length. at each end, Max web Brace ,t w,q ��f Gable Vertical Plate Sizes total length Is 14'.�( 2x4 DF-L #2 or I i O �h'`�/� ('� �p�p Vertical Len th No S lice Less than 4' 0' 1X4 or 2X3 better diagonal tl B ® ,V Greater than 4' 0' 3X4 T '04 Vertical length shown In table bracer single or double cut 8' ti 9 63 7 .a above, 45' (as shown) at 1 - + Refer to common truss design for upper end,uoli;r peak, splice, and heel plates. Connect diagonal nt B +r on�t"VS Bearing ®� __LLii 91 Refer to the Building Designer for conditions midpoint of vertical web, Refer t0 chart abo O�` m Ica ® not addressed by this detail. wwVARNINGIew READ AND F12LLOV ALL NOTES ON THIS DRAVINGI w.IMPORTANTww FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS 'i • {� ° .��,®C 0 ���(� REF ASCE7-10—GAB14015 Trusses require extreme core In fabricating, handling, shipping, Installing and bracing. Refer to and follow the latest edition of BCSI (Bulding Component Safety Information, by TPI and SBCA) for snfrty ('T S lJ C1 ® 6 ® DATE 10/01/14 practices prior to performing these functions. Installers shall provide tenporary brnclng per Bcsl. Unless noted otherwise, top chord shall have attached structural sheathng bottom '�a� i ® L. NA` DRWG A14015ENC101014 properly an chord shall have a properly attached rigid celing. Locations shown for permanent lateral restraint of webs hove bracing Installed BCSI 113, `V, ALPINE shall per sections B7 or BID, as applicable. Apply plates to each face an the ions Details, unless Hated otherwise. of truss and as 160 as shown above plate Refer to drawp ps 160A-2 for standard plate positions, Alpine, a division of ITV Bulding Components Group Inc shall not be responsible for any deviation from AN ITW COMPANY this dr..ing, any Palure to build the truss In conformance with ANSI/TPI 1, or for handling, shlppino, Installatlon L bractng of trusses. AX, TOT. �D, 60 PSF A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional 514 Earth City Expressway englneering responsblUty solely for the design shorn The suitability and use of this drawing =e Suite 242 for any str Is the responsibility of the Building Designer per ANSI/TPI 1 SecZFor Earth City, MO 63045 more g�se web,,�Q Q ustry.org)eIC,, �78 Yoonhwak Kim, FL PE #86367 MAX. SPACING 24.0' ALPINE wwwalpinelt—onloTPberstpinstorgi SBCMI w—sbci r..,c25dfdaFp" Gable Stud Reinforcement Detail ASCE 7-101 140 mph Wind Speed, 30' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Orr 120 mph Wind Speed, 30' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Or, 120 mph Wind Speed, 30' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Orr Inn mnh wind cnppd. 3n' Mpnn Hpinh+. Pnr+InIIV Fnrincod_ r—curc 1T_ 1(v+ = I.nn S 2x4 Brace Gable Vertical Spacing I Species I Grade No Braces (1) lx4 'L' Brace x (1) 2x4 'L' Brace w (2) 2x4 'L' Brace ON (1) 2x6 'L' Brace ■ (2) 2x6 'L' Brace Nil Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B #1 / #2 4' V 6' 11' 7' 2' 8' 2' 8' 6' 9' 9' 10' 2' 12' 10' 13' 4' 14' 0' 14' 0' U S P F #3 3' 10, 6' 2' 6' 7' 8' 1' 8' 5' 9' 8' 10, 0' 12' 8' 13' 2' 14' 0' 14' 0' F Stud 3' 10' 6' 2' 6' 6' 8' 1' 8' 5' 9' 8' 10, 0' 12, 8' 13' 2' 14' C' 14' 0' p Standard 3' 10, 5' 3' 5' 7' 7' 0' 7' 6' 9' 6' 10, D' 11' 0' 11' 10' 14' 0' 14' 0' #1 4' 2' 7' 0' 7' 3' 8' 3' 8' 7' 9' 10' 10' 3' 13, 0' 13' 6' 14' 0' 14' 0' S P #2 4' 1' 6' 11' 7' 2' 8' 2' 8' 6' 9' 9' 1 10' 2' 12, 10, 13' 4' 14' 0' 14' 0' oi F #3 4' 0' 5' 7' 5' 11' 7' 5' 7' 11' 9' 8' 10, 1' 11' 7' 12' 5' 14' 0' 14' 0' Stud 4' 0' 5' 7' 5' 11' 7' 5' 7' 11' 9' 8' 10, 1' 11' 7' 12' 5' 14' 0' 14' C' d Standard 3' 9' 4' 11' 5' 13' 6' 6' 7' 0' 8' 10, 9' 6' 10' 3' 11' 0' 13, 11' 14' 0' #1 / #2 4' 8' 7' 11' B' 3' 9' 4' 9' 9' 11' 2' 11' 7' 14' 0' 14' 0' 14' 0' 14' 0' _ _ S P F #3 4' 5' 7' 6' 8' 3' 9' 3' 9' 7' 11' 0' 11' 6' 14' 0' 14' 0' 14' 0' 1 14' C' L U H F Stud 4' 5' 7' 6' 8' 0' 9' 3' 9' 7' I1' 0' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' w o Standard 4' 5' 6' 5' 6' 10, 8' 7' 9' 2' Ill 0' 11' 6' 13' 6' 14' 0' 14' 0' 14' C' #1 4' 10' 8' 0' 8' 4' 9' 6' 9' 10, 11' 3' 11' 9' 14' 0' 14' 0' 14' 0' 14' 0' S P #2 4' 8' 7' 11' e' 3' 9' 4' 9' 9' I1' 2' 111 7' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 7' 6' 10' 7' 3' 9' 1' 9' 8' I1' 1' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' D F L Stud 4' 7' 6' 10' 7' 3' 9' 1' 9' S. 11' 1' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 5' 6' 0' 6' 5' 8' 0' 6' 7' 10, 10, 11' 6' 12' 7' 13' 15' 14' 0' 14' 0' #1 / #2 5' 2' 8' 9' 9' 1' 10' 4' 10, 9' 11' 2' 12' 9' 14' 0' 14' 0' 14' 0' 14' 0' d S P F 43 4' 10' 8' 7' 8' 11' 10, 2' 10' 7' 12' 2' 12, B' 14' 0' 14' 0' 14' C' 14' 0' LD U H F Stud 4' 10' 8' 7' 8' 11' 10' 2' 10' 7' 12' 2' 12' 8' 14' 0' 14' 0' 14' 0' 14' 0' O I� Standard 4' 10' 7' 5' 7' 11' 9' 11' 10' 7' 12' 2' 12' B' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 4' 8' 10' 9' 2' 10, 5' 10, 10, 12' 5' 12' 11' 14' 0' 14' 0' 14' 0' 14' 0' d 11 -I S P D F L #2 5' 2' 8' 9' 9' 1' 10' 4' 10, 9' 12' 3' 12' 9' 14' 0' 14' 0' 14' 0' 14' 0' #3 5' 0' 7' 10' 8' 4' 10' 3' 10, 8' 12' 2' 12' B' 14' 0' 14' 0' 14' 0' 14' 0' Stud 5' 0' 7' 10' 8' 4' 10' 3' 10' 8' 12' 2' 12' B' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 10' 6' 11' 7' 4' 9' 3' 9' 10, 12' 2' 12' B' 14' 0' 1 14' 0' 1 14' 0' 14' 0' Diagonal brace option, vertical length may be doubled when diagonal brace Is used, Connect diagonal brace for 525# at each end. Max web total length Is 14'. Vertical length shown In table above. Connect diagonal at midooint of vertical ALPIN AN ITW CC 514 Earth City Expressway Suite 242 Earth City, MO 63045 2x6 DF-L #2 or better diagonal brace) single or double cut (as shown) at upper end. aynm Aboutl T IB' � L ,L. race )IE ilE 4� 1 NN `U` Refer to chart abo;k wwVARNINOww READ AND FGLLUV ALL NOTES GN THIS DRAVINGI 0 wwINPGRTANTww FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. pusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and or the latest edition of BCSI (Building Component Safety Information, by TPI and SD CA) for safety ctices prior to performing these functions. Installers shall provide temporaryy bracing per SCSI. ass noted otherwise, top chord shall have properly attached structural sheothlmg and bottom cho 11 have a properly attached rigid ceiling. Locations shorn for permanent lateral restraint of we 11 have bracing Installed per SCSI sections 113, B7 or BIO, as applicable. Apply plates to each face truss and osltlon as shown above and on the Joint Details, unless noted otherwise. t 'er o drawings 160A-Z for standard plate positions. (pine, a division of ITV Building Components Group Inc. shall not be responsible for any deviation fr r drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, :allntion 6 bracing of trusses. seal on this drawng or cover page Usting this drawing, Indicates acceptance of professional Ineering responsibility solely for the design shorn The suitability and use of this drawing any structure Is the rosponsm0lty of the IkAdIng Designer per ANSI/TPI 1 SecZ For more Information see this Job's general notes page and these web siiQQ$$ QQ ALPINE, or.dpineHw.conl 7Pb vatpinsAargl SHCN rrrsbdntlustry.org) 1CG orici'�of Z I IfIIIf1pep Wq� 11*' COR�O� . IS! 4�®IA! ,� 1 Bracing Group Species and Gradesr Group At S ruce-Pine-Fir Hem -Fir #1 / #2 Standard #2 Stud #3 Stud #3 Standard Dou las Flr-Larch Southern Plnewww #3 #3 Stud Stud Standard Standard Group BI Hem -Fir #1 & Btr #1 Douglas Fir -Larch Southern Plnewww #1 1 #1 #2 1 #2 lx4 Braces shall be SRB (Stress -Rated Board), wwFor lx4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group B values may be used with these grades. Gable Truss Detail Notesi Wind Load deflection criterion Is L/240. Provide uplift connections for 100 plf over continuous bearing <5 psf TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with IOd (0.128'x3.0' min) moils. )K For (1) 'L' brace, space nails at 2' o.c, In 18' end zones and 4' o.c. between zones. )K)KFOr (2) 'L' braces, space nails at 3' o,c, In IS' end zones and 6' o,c. between zones. 'L' bracing must be a minimum of 80% of web member length, Gable Vertical Plate Sizes Vertical Len th No Splice + Refer to common truss design for peak, splice, and heel plates. Refer to the Building Designer for conditions not addressed by this detail, Less than 4' 0' 2X4 Greater than 4' 0', but less than 11' 6' 3%4 Greater than 11' 6' 4%4 X. TOT. LD, 60 PSF Yoonhwak Kim, FL PE #86367 (MAX, SPACING 24.0' F ASCE7-10-GAB14030 TE 10/01/14 W G A14030ENC101014 Gable Stud Reinforcement Detail ASCE 7-101 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Ori 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Ord 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or, 120 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure D, Kzt = 1.00 S 2x4 Brace Gable Vertical pacing Species Grade No Braces (1) lx4 'L' Brace ■ (1) 2x4 'L' Brace x (2) 2x4 'L' Brace rr (1) 2x6 'L' Brace Ie (2) 2x6 'L' Brace I[ Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B -P #1 / #2 3' 10' 6' 7' 6' 10' 7' 9' 8' I' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' - S P P #3 3' 6' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' F Stud 3' B' 5' 9' 6' 1' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12, 6' 14' 0' 14' 0' o Standard 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' 11' 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' Q1 J S P #1 4' 0' 6' 8' 61111 7' 10' 8' 2' 9' 4' 9' 6' 12' 4' 12' 9' 14' 0' 14' 0' #2 3' 10' 6' 7' 6' 10' 7' 9' e' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, ill 11' 8' 14' 0' 14' 0' oj P Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' ill 6' 14' 0' 14' 0' d Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U -P S P P #1 / #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' 03 4' 2' 7' 1' 7' 9' 8' 9' 9' 1' 10, 5' 10, 10, 13' 9' 14' 0' 14' 0' 14' 0' lJ l l P Stud 4' 2' 7' 1' 7' 6' 8' 9' 9' 1' 10' 5' 10, 10, 13' 9' 14' 0' 14' 0' 14' 0' O fl Standard 4' 2' 6' 1' 6' 5' B' 1' 8' 6' 10' 5' 10' 10, 12' 8' 13' 7' 14' 0' 14' 0' \ #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10, 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' / S P #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14, 0' #3 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10, I1' 13' 4' 14' 0' 14' 0' 14' 0' QJ D P L Stud 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10, II' 13' 4' 14' 0' 14' 0' 14' 0' Standard 4' 2' 5' 8' 6' 0' 7' 6' 8' 0' 10' 2' 10, 10, 11' 10, 12' 7' 14' 0' 14' 0' 0 #1 / #2 4' 10' 8' 3' 8' 7' 9' 9' 10, 2' 10' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' d S P P #3 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' Ill 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' <J u P Stud 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' O I� Standard 4' 7' 7' 0' 7' 5' 9' 4' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 1' 8' 5' 8' 8' 9' 11' 10, 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3' 8' 7' 9' 9' 10, 2' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' 11 CU #3 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' .--I D P L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 14' 0' 14' 0' 14' 0' Diagonal brace options vertical length may be doubled when diagonal brace Is used, Connect diagonal brace for600# at each end. Max web total length Is 141. Vertical length shown In table above. Connect diagon6l at midooint of vertical ALPIN AN ITW CC 514 Earth City Expressway Suite 242 Earth City, MO 63045 2x6 DF-L #2 or better diagonal brace, single or double cut (as shown) at upper end, aymm AboutrS T 1B'+ L :ace I I T 8' X J- 1 Vial Vri 1411, Refer to chart abo wsVARNINGIs- READ AND FOLLOV ALL NOTES ON THIS DRAVINO it --IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. W/ Trusses require extreme care In fabricating, handling, shipping, hstotling and bracing. Refer to and Y bile. the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety •actices prior to performing these functions. Installers shalt provide temporary sbracingd per BCSI. iles noted otherwise, top chord shall hour properly attached structural hrnthing anbottom chord natl hove a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs iall hove bracing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to each face ' truss and ositbn as shown above and on the Joint Details, unless noted otherwise. nfer to drawings 160A-Z for standard plot. positions. Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any deviation from Js drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, stallatlon L bracing of tes. A seal on truss his drawing or cover page Ustbg this drawing, 6xDcates acceptance of professional Vi neering responsibility solely for the design shorn The suitability and use of this drawkq nr any structure Is the responsibility of the Building Designer per ANSI/TPI 1 SecZ For more Information see this Job's general notes page and these web aII{{��QQf' ALPINE, www.alpineltw.coni TPI, www,tpinst.orgi SBCN vw.sbclndustry.orgi ICO wwwJc�laf Z78. WAA- �� • • `Irl • mane 19111MG-Ven-ClU eSIONA1� 0104aNiII11 0 Bracing Group Species and Grades) Group At S ruce-Pine-Fir Hem -Fir #1 / #2 Standard #2 Stud #3 Stud1 #3 IStanclardl Dou las Fir -Larch Southern Plnexxx #3 #3 Stud Stud Standard I Standard Group III Hem -Fir #1 6 Btr #1 Dou l 's Fir -Larch Southern Pinewlww #1 #1 #2 #2 lx4 Braces shall be SRB (Stress -Rated Board). ■sFor lx4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards, Group B values maybe used with these .moles. Gable Truss Detail Notes) Wind Load deflection criterion Is L/240. Provide uplift connections for 75 plf over continuous bearing (5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang, Attach 'L' braces with 10d (0.128'x3,0' min) nails. )K For (1) 'L' braced space nalls at 2' o.c. In 18' end zones and 4' o.c. between zones. )K)KFor (2) 'L' braces, space malls at 3' o.c, In IS' end zones and 6' o.c, between zones. 'L' bracing must be a minimum of 80% of web member length, Gable Vertical Plate Sizes + Refer to common truss design for peak, splice, and heel plates. Refer to the Building Designer for conditions not addressed by this detall. REF ASCE7-10-GAB16015 DATE 10/01/14 DRWG A16015ENC101014 Vertical Len th No Splice Less than 4' 0' 2X3 Greater than 4' 0', but less than 11' 6' 3X4 Greater than 11' 6' 4X4 AX. TOT. LD, 60 PSF Yoonhwak Kim, FL PE #86367 iMAX, SPACING 24,0' Gable Stud Reinforcement Detail ASCE 7-101 160 mph Wind Speed, 30' Mean Height, Enclosed, Exposure C, Kzt = 1.00 ❑rl 140 MPH Wind Speed, 30' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Or 140 mph Wind Speed, 30' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or, 1Pn mnh Wlnd Snppd. 3n' Ill— Nolnh+_ Pnr+lnlly Par-Incod. Cvnn, , ,o 7) IC-r+ = inn S 2x4 Brace Gable Vertical pacing Species Grade No Braces (1) lx4 'L' Brace x (1) 2x4 'L' Brace IN(2) 2x4 'L' Brace ww (1) 2x6 'L' Brace IK (2) 2x6 'L' Brace No Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B #1 / #2 3' B. 6' 3' 6' 6' 7' 5' 7' 8' e' 9' 9' 2' 11' 7' 12' 0' 13' 9' 14' 0' U S P F #3 3' 6' 5' 5' 5' 9' 7' 2' 7' 7' 8' 8' 9' 1' 11' 3' Ill ill 13' 7' 14' 0' IJ Stud Stud 3' 6' 5' 4' 5' 8' 7' 2' 7' 7' 8' 8' 9' 1' 11' 2' 11' 11' 13' 7' 14' 0' O f l 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13, 1' 14' 0' #1 3' 10' 6' 4' 6' 7' 7' 6' 7' 9' 8' 11' 9' 3' 11' 9' 12' 2' 13' 11' 14' 0' —J S P #2 3' 8' 6' 1' 6' 6' 7' 5' 7' B' 8' 9' 9' 2' 11' 7' 12' 0' 13' 9' 14' 0' #3 3' 7' 4' 10' 5' 2' 6' 5' 6' I1' 8' 9' 9' 1' 10, 1' 10, 10' 13, 8' 14' 0' Stud 3' 7' 4' 10' 5' 2' 6' 5' 6' ill 8' 9' 9' 1' 10, I' 10, 10' 13' 8' 14' 0' d Standard 3' 3' 4' 3' 4' 7' 5' 8' 6' 1' 7' 9' 8' 3' 8' ill 9' 7' 12' 2' 13' 0' U _ #1 / #2 4' 2' 7' 2' 7' 5' 8' 5' B' 9' 10, 1' 10, 6' 13' 3' 13' 9' 14' 0' 14' 0' S P F # 3 4' 0' 6' 7' 7' 5' 8' 4' 8' B' 9' 11' 10' 4' 13' 1' 13' 7' 14' 0' 14' 0' L U LJ P Stud 4' 0' 6' 7' 7' V 8' 4' 8' 8' 9' 11' 10' 4' 13' V 13' 7' 14' 0' 14' 0' 1 o f l Standard 4' 0' 5' 8' 6' 0' 7' 6' B' 0' 9' ]I' 10' 4' 11' 10' 12' 8' 14' 0' 14' 0' \ #1 4' S' 7' 3' 7' 6' B' 7' 8' 11' ]0' 2' 10' 7' 13' 5' 13' 11' 14' 0' 14' 0' / S P #2 4' 2' 7' 2' 7' 5' 8' 5' 8' 9' 10, 1' 10' 6' 13' 3' 13' 9' 14' 0' 14' 0' #3 4' V 5' 11' 6' 4' 7' 11' B' 5' 10, 0' 10' 5' 12' 5' 13' 3' 14' 0' 14, 0' D F L Stud 4' V 5' 11' 6' 4' 7' 11' 8' 5' 10, 0' 10' 5' 12' 5' 13' 3' 14' 0' 14' 0' Standard 4' 0' 1 5' 3' 5' 7' 7' 0' 7' 6' 9' 5' 10, 2' 11' 0' 11' 9' 14' 0' 14' 0' #1 / #2 4' 8' 7' 11' 8' 2' 9' 4' 9' 8' 10, 1' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' d S P F #3 4' 5' 7' 7' 8' 1' 9' 2' 9' 6' 10' 11' 11' 5' 14' 0' 14' 0' 14' 0' 14' 0' LD U H F stud 4' 5' 7' 7' 8' 1' 9' 2' 9' 6' 10, 11' 11' 5' 14' 0' 14' 0' 14' 0' 14' 0' O I� Stnndnrd 4' 5' 6' 6' 6' 11' 8' 8' 9' 3' 10, 11' 11' 5' 13' 7' 14' 0' 14' 0' 14' 0' X #1 4' 10' 8' 0' 8' 3' 9' 5' 9' 9' 11' 2' 11' 8' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 8' 7' 11' 8' 2' 9' 4' 9' 8' ]1' 1' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 6' 1 6' 10' 7' 3' 9' 1' 9' 7' ]1' 0' 11' 6' 14' 0' 14' 0' 14' 0' 14, 0' a—i D F L 1 Stud 4' 6' 1 6' 10' 7' 3' 9' 1 9' 7' ]1' 0' 11' 6' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' S' 6' 1' 6' 5' 8' 1' 8' 7' ]0' 11' 11' 5' 1 12' 8' 1 13' 7' 1 14' 0' 14' 0' Bracing Group Specles and Grades) Group At S ruce-Pine-Fir Hen -Fir ql / #2 Standard q2 Stud q3 Stud q3 Standard Dou las Fir -Larch Southern Plnewww #3 1 #3 Stud Stud Standard dj Group BI Hen -Fir q1 6 Btr ql Dou as r-Larch Southern Plneww■ #11 #1 q21 02 lx4 Braces shall be SRB (Stress -Rated Board). rwFor Ix4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards, Group B values may be used with these grades. Gable Truss Detail Notest Wind Load deflection criterion Is L/240, Provide uplift connections for 135 plf over continuous bearing (5 psf TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. About ) Attach 'L' braces with 10d (0.128'x3.0' min) malls. able Truss )K For (1) 'L' brace, space nails at 2' o.c. In IS' end zones and 4' o.c, between zones. Diagonal brace option, )K)1(For (2) 'L' braces, space malls at 3' o,c, vertical length may be T in IS' end zones and 6' o,c. between zones. doubled when diagonal e 18' X 'L' bracing must be a minimum of 80% of web brace is used. Connect diagonal brace for 690# -- L •L' member length. at each end, Max web Brace �t A /// Gable Vertical Plate Sizes total length Is 14'. I 2x6 DF-L q2 or —n e , /�' Or �t r+ rI� /��� Vertical Len th No Splice Less than 4. 0' 2X4 better diagonal 'r 4� e C \V Greater than 4' 0', but �o i J 4X4 Vertical length shown In table brace) single a or double cut 8. ® � 7 ,e less than 12' 0' above. 45' (as shown) L 1 at upper end,LAWL )wQQpeak, + Refer to common truss design for splice, and heel plates. Connect diagonal at onp +ems®Bearing e 'r Refer to the Building Designer for conditions _ 17 midpoint of vertical web. Refer to chart abo $C a off' mav� Ica not addressed by this detail. NNVARNINGiww READ AND FOLLOW ALL NOTES W THIS DRAWING ..IMPORTANT.. FURNISH THIS DRAWING TO ALL CWTRACTORS INCLUDING THE INSTALLERS. //�C�e�►� '` p quw' / REF ASCE7-10-GAB16030 Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and f� allow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety 3 ® 0 ®d is�'1 a ®® ® DATE 10/01/14 practices prior to performing these functions. Installers shalt provide temporary bracing per BCSI. Unless noted otherwise, top have ,r j(1AY ' ® Y DRWG A16030ENC101014 chord shall properly attached structural sheathing and bottom chord shall have a properly attached rigid calling. Locations shown for permanent lateral restraint of webs / 6� 1 %/®d pis► 10461., shall have bracing Installed per BCSI sellon, 83, 117 — 111, as applicable, Apply plates to each face truss ALPINE of aM pposition -Z shown above and on the i Joint Details, unless noted otherwise. Refer to drawlnps 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any deviation from )AX. this drawing, any faKure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, TOT, LD, 60 PSF AN ITWCOMPANY Installation 6 bracing of trusses. seatInp this cirawingor cover page this drawing, Indicates acceptance of professional 514 Earth CI Ex resswa IY P Y enA dating ty O^ sham The suttabllty and use of this drawing Suite 242 for any structw2 Is the responsibility of the Building Designer par ANSI/TPI 1 Sec2. MAX, SPACING 24,0 Earth City, MO 63045 For more Information see this Job's general notes page and these webs ALPINE, www.alptneitw.con, TPI, wwr.tpinst.orgi SBCAi xaw.sbcIndustry.orgl ICG uw1 j }',[ PF IE CLR Reinf orcing Member Substitution T-Reinforcement This detail is to be used when a Continuous Lateral Restraint (CLR) or T-Reinf, Is specified on a truss design but an alternative web L-Reinforcementi or reinforcement method Is desired, L-Reinf, Notes; This detail Is only applicable for changing the specified CLR shown on single ply sealed designs to T-reinforcement or L-relnforecement or scab reinforcement, Alternative reinforcement specified in chart below may be conservative, For minimum alternative reinforcement, re -run design with appropriate reinforcement type. Web Member Specified CLR Alternative Reinforecement Size Restraint T- or L- Reinf, Scab Reinf, 2x3 or 2x4 I row 2x4 1-2x4 2x3 or 2x4 2 rows 2x6 2-2x4 2x6 1 row 2x4 1-2x6 2x6 2 rows 2x6 2-2x4OK) 2x8 1 row 2x6 1-2x8 2x8 2 rows 2x6 2-2x6OK) T-reinforcement, L-reinforcement, or scab reinforcement to be same species and grade or better than web member unless specified otherwise on Engineer's sealed design, 00 Center scab on wide face of web, Apply (1) scab to each face of web. Apply to either side of web narrow face. Attach with 10d (0,126'x3,0',min) nails at 6' o.c. Reinforcing member Is a minimum 80% of web member length. Scab Reinforcement: Apply scab(s) to wide face of web. No more than (1) scab per face. Attach with 10d (0,126'x3,0',min) nails at 6' o,c, Reinforcing member Is a minimum 80% of web member length. ��NO",Q AH WA/1 .�0 CENS���?� No, 86367 Scab T-Reinf. L-Reinf. wwWARNING- READ AND F1ILLUW ALL RITES [IN THIS DRAWING PAQ .IMPORTANT.. FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS, ��, ®®4-0 "7,4 C LL PSF REF CLR Subst, Trusses require extreme ..are In fabricating, handling, shipping, InrtolBrg u d bracing, Refer to ety „{� 4� C Op9IC1�k `` T(�' DL PSF DATE 10/01/14 f Ile the latest edition of BCSI RButtding Corponent Safety lnfornatlon, y TPI and SBCA> for safety i-`, V pprr cticea prior to performing these functions. Installers shall provide tempereryy bracing per BCSI. O 6 O Unlrss natal otherwise, top chord shall have properly attached rtructural sheathing aM bottom chord e�®lSs+ • m Q r B DL PSF DRWG BRCLBSUB1014 shall have a properly attached rigitl ceRing. Locations shown for permanent lateral restraint of webs j� I ft I p ` �- 1 ALP shall have and rosi installed per BCSI sections B3, J BIG, s untess no Apply plates to each face 0 `�' 1 H 6- O 111 Refrruto fowl osltion s sham above and on the Joint Details, unlasr noted otherwise. i�0 �� `'+� C LL PSF rps 160A-Z for standard plate positions. �� lf'4 Alpine, a division of ITv Building Components Group Inc. shall of be ponsible for any deviation iron T LD, PSF ,Vd Rw COMPANY this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, Installation i bracing of trusses. 11 seal on tX drnhg cover page UstYp this drawing, Indkates acceptance of professional 13723 Riverpon Drive wngk,ewrkg rezpons�lty zdHy for thw aezign shown The sulta" and use of this drawing D R, FAC, Suite 200 for any structure is the respaWbelty of the Bolding Designer per ANSLnPI 1 SecZ Maryland Heights, MO 63043 for more Information see this Job's general rotes pp pe and these web sites, ALPINE, www.*Iptneltw.comi TPD www.tpinst.crgi SBCA, wwwsbckMustryargl ICG wwrlccsafe.org PACING PFWY T0t�0G78, Yoonhwak Kim, FL PE #86367 Commentary: Camber May be built into trusses to compensate for the vertical deflection that results from the application of loads, Providing camber has the following advantages: • Helps to ensure level ceilings and floors after dead loads are applied, • Facilitates drainage to avoid ponding on flat or Low slope roofs, • Compensates for different deflection characteristics between adjacent trusses • Improves appearance of garage door headers and other long spans that can appear to 'sag,' • Avoids 'dips' in roof rigelines at the transition from the gable to adjacent clear span trusses, Deflection and Camber In accordance with ANSI/TPI 1 the Building Designer, through the Construction Documents, shall provide the Location, direction, and magnitude of all loads attributable to ponding that may occur due to the design of the roof drainage system, The Building Designer shall also specify any dead load, live load, and in-service creep deflection criteria for flat or low -slope roofs subject to ponding Loads. The amount of camber is dependent on the truss type, span, loading, application, etceteras, More restrictive limits for allowable deflection and slenderness ratio (L/D) may be required to help control vibration. The following tables are provided as guidelines for limiting deflection and estimating camber, Conditions or codes may exist that require exceeding these recommendations, or past experience may warrant using more stringent limitations, L = Span of Truss (Inches) D = Depth of Truss at Deflection Point (inches) ------------------------------------------------------------------------- Recommended Truss Deflection Limits Truss Type L/D Deflection Limits Live Load Total Load Pitched Roof Trusses 24 L/240 (vertical) L/180 (vertical) Floor of Room -In -Attic 24 L/360 (vertical) L/240 (vertical) Trusses Flat or Shallow Pitched 24 L/360 (vertical) L/240 (vertical) Roof Trusses Residential Floor Trusses 24 L/360 (vertical) L/240 (vertical) Commercial Floor Trusses 20 L/480 (vertical) L/240 (vertical) Scissors Trusses 24 0,75' (horizontal) 1,25' (horizontal) ------------------------------------------------------------------------- Truss Type Recommended Camber Pitched Trusses 1.00 x Deflection from Actual Dead Load Sloping Parallel 1.5 x Vertical Deflection from Chord Trusses Actual Dead Load Floor Trusses (0,25 x Deflection from Live Load) + Actual Dead Load >tllillf!/i//��p Flat Roof �,�WAOx Deflection from Live Load) + Note: wwVARNINGIww READ AND FULLUV ALL NOTES ON THIS DRAVINGI m111PORTANT.• FURNISH THIS BRAVING TO ALL CONTRACTORS INCLUDING THE INSTALLERS, Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to an follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safet practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom ch shall hove a properly attached rigid celling. Locations shorn for permanent lateral restraint of we shall hove bracing Installed per BCSI sections B3, B7 or BID, as applicable. Apply plates to each fnc LPI N E of truss and position form above and on the Joint DataDs, unless rested otherwise. Refer to drawings ion a. for standard plate positions. Alpine, a division of ITV Building Components Group Inc. shall of be responsible for any deviation f this drawing, any failure to bu0.tl the truss In conformance with ANSI/TPI 1, or for handling, shipping, AN ITW COMPANY installation 6 bracing of trusses. A seal on this drar4g or cover page Usting this drnw1mg, Indicates acceptance of professional 514 Earth City Expressway engineering responsibility solely for the design shorn The suitability and use of this drnwImg suite 242 for any structure Is the respoathility of the BuBding Designer per ANSI/TPI I Sect. EarthCity, MO 63045 For more Information see this Job's general notes page and these web n' ALPIN, www.olpinelt .cam, TPB rww.tpIm t.orgj SBCA. wwr.sbdndustry.org, 1C. wow dj \GE�°ee%4p9 Design Dead Load Deflection) Y S� i xe �etkygl �asl mc' be considerably less than e i 00.C% • � b STATE OF �o�,C�er� ������• ° ,mom C REF DEFLEC/CAMB v eF0 °sees ° �� DATE 10/01/14 ord "`"46SIONAL ► DRWG DEFLCAMB1014 1. 'T' Reinforcing Member Gable Truss Gable Detail For Let -in Vertic-nlc; Dpropriate Alpine gable detail for e sizes for vertical studs, Engineered truss design for peak, b, and heel plates, vertical plates overlap, use a to that covers the total area of ,upped plates to span the web, 2*2X4 2X8 h'rovide connections for uplift specified on the engineered truss design. Attach each 'T' reinforcing member with End Driven Nailsr IOd Common (0,148'x 3',min) Nails at 4' o.c, plus (4) nulls In the top and bottom chords. Toenalled Nailsr 10d Common (0,148'x3',min> Toenails at 4' o,c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detall Drawings A11515ENC100118, A12015ENC100118, A14015ENC100118, �41G�1dd1!@h/y� A18015ENC100118, A20015ENC100118, A20015END10011�lMf A11530ENC100118, A12030ENC300118, A14030ENC10�i� i3CV1EW 04UT,r4' / A18030ENC100118, A20030ENC100118, A20030EN 0 �, A8 SI1515ENC100118, 512015ENC100118, S14015EN0116 S96�CI99P1�@# S18015ENC100118, S20015ENC100118, S20015E*10011W S?e0,15P IQ0�8_� S11530ENC100118, S1203DENCICO118, S14030EZCI00I98, S S18030ENC100118, S20030ENC100118, S20030�IJjj7p0ie, S20030PED10DI18 0 ��>halt See appropriate Alpine gable detail for maxlmZ unnielnforced"g*Mertical I0 °. STATE OF 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe -nail - Or - End -mall To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member, Web Length Increase w/ 'T' Brace Exampler ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o.c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 30% = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' 'T' Relnf, Mbr. Size 'T' Increase 2x4 30 2x6 20 IdALUnless ® ALPINE r-WARNINGiww READ AND FOLLOW ALL NOTES EN THIS DRAWINGI ® --WnRTANTww FURNISH THIS DRAWING To ALL CONTRACTORS INCLUDING THE INSTALLERS. °sP Trusses require extreme care In fabricating, handling, shipping, Installlng and bracing. Refer to and follow the latest edition of BCSI (Bu4ding Component Safety Information, by TPI and SBCA) for safety practices prior to performing -these functions. Installers shall provide temporaryy bracing per BCS1. noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections B3, H7 or BID, as applicable. Apply plates to each face a position as shorn above and on the Joint Details, unless noted otherwise. Refer to andion as for n above plate positions. Re truss drawings r{, + C Q Q� �v d' `) ° ® ��� S/ A+�1 e ® 6. 1 ji%I%„`'),� C REF LET - I N V E R T DATE 01/02/2018 DRWG GBLLETINO116 AN ITW COMPANY 514 Earth City Expressway Suite 242 Earth City, MO 63045 Alpine, o dNislon of ITV Building Components Group Inc shall not he responsible for any deviation from this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, Installation L bracing f trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional enghwering responsibility solely for the design shorn The suftnbYlty and use of this drawbv for M structure k the rQ y sponcBmty of the BuadYp Designer per ANSI/TPI I Sect. For more Information see this Job's general notes page and these web sit(p�(yt���78 ALPINEi vw.olpineltr.conl TPD rwrtpinst.orgl SBCN vrsbdndustryargl ICG vrJcCsaF yoonhwak Kim, FL PE #863G7 )AX. TOT, LD, 60 P$F DUR, FAC, ANY :::] MAX, SPACING 24,0' W- 'T Relnfoi Memk Go, Tr Gable Detail Fnr, I at —in Vpr,+Ir-nl<-- Gable Truss Plate Sizes pproprlate Alpine gable detail for e sizes for vertical studs. Engineered truss design for peak, b, and heel plates. vertical plates overlap, use a to that covers the total area of lapped plates to span the web, 2X4 2X4 2X8 rroviae connections tor uptirt specitiea on the engineerea truss aesign. Attach each 'T' reinforcing member with End Driven Nallst IOd Common (0,148'x 3.',min) Nails at 4' o,c. plus (4) malls In the top and bottom chords, Toenalled Nallsi IOd Common (0,148'x3',min) Toenalls at 4' D.C. plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load, ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 Gable Detall Drawings e�tt FF��cc A11515ENC101DI4,-A12015ENC101014, A14015ENC101014, 1 ��NE103V1��//j0 A1153DENC101014, A12030ENC101014, A14030ENCIOlO'r3��C101p1�r0A18030ENCIOIDI4, A20030ENC101014, A20030EN Sj :"5 g r S11515ENC100815, S12015ENC100815, S14015EbO815e�1• S18015ENC100815, S20015ENC300815, 5200151ID1008�5, �,8 511530ENC100815, S12030ENC100815, S14030�IC100615, S'% p S18030ENC100815, S20030ENC100815, SEDOAt7ii CAB15, S2003OPED100815 0 • 0 See appropriate Alpine gable detail for maxlmiwLm unr(RlnforcecI '5 ^ertical IS "JARNINGIww READ AND FOLLOW ALL NOTES ON THIS DRAVINGI 0-IMPORTANT.. FURNISH THIS DRAVING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to an follow the latest edition of SCSI (Bulding Component Safety Information, by TPI and SBCA) for safet practices prior to performing these functions. Installers shall provide tenporory brocing per BCSL Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom ch sholt have a properly attached rigid ceiling. Locations shown for pertinent lateral restraint of wel ALI_�IPFDI shall have bracing installed per abo sections th J or Det ils unlessapplicable. Apply platesrwise. to each fart oftruss and position ns shown above pl on the Joint Detn0.s, uMess noted otherwise. Refer to drawings 160A-Z for standard plate positions. AN lTW C7DMPANY thispdowing, nlynof ITW failure to buAd he truss In Gconffoup rn conformance witnot RNSLresponsible, oro� li deviation dung, shipping, Installation L of trusses. A seal onthishis drawing so cover page listing shothis m he Indicates acceptance o of professional nnl Suite Riverport Drive far an rlrg structure mil rely for the design shown The suitability per and use of thic:Z drawing Suite 200 for any structure k responsibility of the BultlYp Designer per ANSI/TPI 1 Seee. Maryland Heights, MO 63043 For more Information see this Job's general notes page try.org, ICo wwwland these web sl 7) ALPINE, www.olpinelte.coml TPb www.tpinst.orgl SBCA- www.sbc[ndc 9 STATE OF I Yoonhwak Kim, FL PE #86367 'T' Reinforcement Attachment Detail 'T' Reinforcing 'T' Reinforcing Member Member Toe-nall - Or - End-nall To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member. ✓eb Length Increase w/ 'T' Brace 'T' Relnf, Mbr. Size 'T' Increase 2x4 30 X 2x6 20 X Example) ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o.c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 307 = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' TOT. LD, 60 PSF FAC, ANY SPACING 24,0' REF LET —IN VERT DATE 10/01/14 DRWG GBLLETIN1014 RIGID INSERT DETAIL — REINE❑RCEMENT FOR HIGH STRESS C❑MPRESSI❑N J❑INTS THIS DETAIL IS TO BE USED WHEN STRESS AT A C❑MPRESSI❑N SPLICE EXCEEDS 75% OF THE ALLOWABLE C❑MPRESSI❑N STRESS PER TPI 1 SECTI❑N 7,3,9,2 ❑PTI❑N #1: APPLY A 20 GAGE MINIMUM METAL INSERT BETWEEN BUTTED ENDS OF C❑MPRESSI❑N CHORD MEMBERS TO FULLY COVER THE J❑INT BEARING AREA. BEND RIGID INSERT OVER THE TOP ❑R BOTTOM OF THE C❑MPRESSI❑N MEMBER A MINIMUM OF 1r AND SECURE IN PLACE WITH A KEEPER NAIL, KEEPER NAIL IS TO BE SIZED AND SPACED TO AV❑ID SPLITTING OF THE LUMBER, '--1,0" MIN 00 o KEEPER NAIL RIGID IN ERT J❑INT L❑CATI❑ ❑PTI❑N #21 APPLY A 20 GAGE MINIMUM METAL INSERT WITH SLOTTED TEETH BETWEEN BUTTED ENDS OF C❑MPRESSI❑N CHORD MEMBERS TO FULLY COVER THE J❑INT BEARING AREA, HAMMER RIGID INSERT SECURELY IN PLACE AND FLUSH WITH BUTTED END, 00 0 - `��t�itttrlrrrr►pofs ® PIP CENS ®Na, 8636kv + IGIII+ INSSRT WITH JOINT RIGI INSERT s ¢.,� A PItS1M OF L❑CATION 5% Sh°�CD (V❑ID) STATE OF + A. rrVARNDIOww READ AND Frw i m, ALL NOTES DN THIS DRAVDRB itF FURNISH THIS DRAVING TD ALL CONTRACTDRS INCLUDING THE INSTALLERS. �i• Trusses require extreme care N fabricating, h.ndtlng, shipping, Installing and bre� Referfall..thelatest �g■NIW13RTANT.. COiCv�C LL PSF REF RIGID INSERT 10��1�14 vtlltlon oP HCSI (Building Component Safety information, by TPI antl SBCA> for safety°� prior to performing these functions. Installers shall provide temporary br.cing per BCSI. j�+�`DATE ®L DL PSFpr.ctices Unless noted otherrise, top chord shall have properly attached structural sheathing antl bottom chor shall have a properly attached rigid ceiling. Locations shorn for pernanent lateral restraint of websdddd j t�� �i8i�r+� BC DL PSF ® shall have bradng Installed per BCSI sections 113, 37 or B10, as applicoble. Apply plates to ...h face DRWG RIGINSRT1014 ALPINE of {ruse andposition as shorn above and on the Joint Details, unless noted otherwise. Refer to andrtn9sposi ion as for standard plate positions, aJoin C LL PSF Alpine, a division of ITV Building Components Group Inc. shall not be responslbte for any deviation from this dra.ing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, sWpping, ❑T, LD, PSF AN lTW COMPANY 514 Earth City Expressway art installation 6 br..Ing of trusses. A seal on Ws drarh�g or cover page llsting this drawlrg, Wlkntes acceptance of professional englneerb,g responsWll ty solely for the design shorn The sultohulty and use of this drawing u f this dt DUR, FAC, Suite Earth City, MO 63045 for an structure Is the re n I 1 Y responsibility f the Bu0.ding Designer per ANSI/TPI For more information see this Job's general notes page and these web sit / Yoonhwak Kim, FL ALPINE, wwmalpineltw.com) TPI, rww.tpinst,orgl SBCA, wrwsbcindustry,orgr IM ww.1c s PE #86367 SPACING w, a ` ' STRONGBACK BRIDGING REC❑MMENDATI❑NS BUTT STRONGBACK BRIDGING TOGETHER 4' -Qa ATTACH SCAB WITH IOd BOX/GUN 4' -0' 2x6 (0.128'x3.0') NAILS IN 2 ROWS AT SCAB 6' O.C. NOTE, IN LIEU OF SPLICING AS SHOWN, LAP STRONGBACK BRIDGING MEMBERS FOR AT LEAST ONE TRUSS SPACING STRONGBACK BRIDGING SPLICE DETAIL NOTE, Details 1 and 2 are the preferred attachment methods ATTACH STRONGBACK TO ACM WEB W/ (3) lOd COMMON O (0,148'x3') NAILS OR (4) 10d BOX/GUN O �28'x3,0') NAILS ram\ / / J (2) lOd COMMON (0.148'x3.0') OR BOX/GUN (0.128'x3.0'> NAILS AT TOP AND BOTTOM OF 2x4 SCAB -ON BLOCK, ATTACH STRONGBACK TO BLOCK W/ (3) 10d COMMON (0.148'x3,O') NAILS OR (4)I0d BOX/GUN (0,128'x3.0') NAILS, O 0 a STRONGBACK BRIDGING SPACING REQUIREMENTS Up to 10' None re ulred 10' to 20' 1 raw (at center of spyO 20' to 30 2 rows 0 at each 1/3 ts) 30' to 40 3 rows 0 at each U4 DoInts) Over 40Space rows at 10' ac. *ts) 0 a ATTACH Sw`m TO BOTTIP (2) #10, STRONGBACK BRIDGING ATTACHMENT ALTERNATIVES w rsVARNINGHr READ AND FOLLOV ALL NOTES W THIS DRAVINGI d -INPORTANTn FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions, Installers shall provide temporary bracing per SCSI, Unless noted otherwise, top chord shall have properly attached structural sheaihIng and bottom cho shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections B3, B7 or Hla, as applicable. Apply plotes to each face LPI N E of truss d position o horn above and on the Joint Details, unless noted otherwise. Refer to drawings ionIGDA-Zas for n above plate positions. Alpine, a division of ITV Hultding Components Group Inc, shall of be responsible for any deviation fr, this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, AN ITW COMPANY Installation 6 bracing of trusses. A seal on this 51_Ing or cover page listing this drawing, Indicates acceptance of professional 514 Earth City Expressway en ,img responsibility solely for the design shown The suitability and use of this drawing Suite 242 for any structure Is the responsibility of the Building Designer per ANSI/TPI 1 Sec2. Earth City, MO 63045 For more Information see this Job's general notes page and these web sites, ALPINE, wwiaalpinelt_j TPL •ww.ipinst.orgl SBCA, rwr,sbcindustry.orgl ICC, ry 6 WITH ► All scab -on blocks shall be a minimum 2x4 ,stress graded lumber." ► All strongback bridging and bracing shall be a minimum 2x6 "stress graded lumber.' ► The purpose of strongback bridging is to develop load sharing between individual trusses, resulting in an overall Increase in the stiffness of the floor system, 2x6 strongback bridging, positioned as shown in details, is recommended at 10' -0' o,c, (max,) me -The terms "bridging' and 'bracing' are sometimes mistakenly used interchangeably. 'Bracing' is an important structural requirement of any floor or roof system, Refer to the Truss Design Drawing (TDD) for the bracing requirements for each Individual truss component, 'Bridging,' particularly 'strongback bridging' is a recommendation for a truss system to help control vibration, In addition to aiding in the distribution of point loads between adjacent truss, strongback bridging serves to reduce 'bounce' or residual vibration resulting from moving point loads, such as footsteps. The performance of all floor systems are enhanced by the installation of strongback bridging and therefore is strongly recommended by Alpine, For additional information regarding strongback bridging, refer to BCSI (Building Component Safety Information), IM 116Ff HWAk'`tRr/ ,CENS* 66367 s � y 3 +fir /A 1 E nl: °6� �o`D�4L, I0 eL�DL 4��aH LL PSF PSF C DL PSF PSF REF STR❑NGBACK DATE 10/01/14 DRWG STRBRIBR1014 7LL T T. LD. PSF DUR, FAC, 1,00 SPACING ,0 I- VALLEY FRAMING 8, BRACING DETAIL I R BC Lumber Size and Grade Minumum Requirements TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max. ce the crippes for each row starting from the valleys or sleepers working inward to the ridge board so that cripple locations are gered between rows. (TYp) innection Reguirement Notes 2x6 rafters to ridge 416d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 416d toe -nails (••) 816d face -nails Rafter to sleeper or blocking 516d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 316d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 3 16d toe -nails Truss to blocking 4 16d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 316d toe -nails °­ �"`�� —, ""`�`r"' — """ i 13. Collar beam to rafter 416d toe -nails Purlins required 2'-0" O.C. in absence of plywood sheathing. GENERAL NOTES CRIPPLE, BRACING, 8t BLOCKING NOTES NOTE: 16d(0.162"x3.5")COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0" to 10'-0" Ion Trusses without sheathing applied must be evaluated accordingly. nailed w/ 2 -10d (0A48"x3") nails. Or 2x4 "T' or scab reinforcement nailed to flat edge Purlins should overlap sheathing one truss spacing minimum. of cripple with 10d J0.128"x3.0") nails at 6" o.c. "T' or scab must be 90 % of cripple length. In cases that this is impractical, overlap sheathing a minimum Cripples over 10'-0' long requre two CLR's or both faces w/ "T" or scab. Use stress of 6", and nail upwards through sheathing into purlin with a graded lumber & box or common nails. minimum of 8-8d (0.131"x2.5") common wire nails. :Narrow edge of cripple can face ridge or rafter, Effects of -not providing sheathing below a -valley -set— - --- as -long -as -the proper -number -of nails are must be evaluated by the building designer. installed Into ridge board This drawing applies to valleys with the following conditions: -Install blocking under rafter if sleepers are not used. Spans (distance between heels) 40'-0" or less -Install blocking under cripples if cripples fall between Maximum valley height: 14'-0" lower truss top chords and lateral bracing Is not used. -Maximum mean roof height: 30 feet Apply all nailing accordance current require Nails are commonn wire nails unless otherwise noted otherwise N, f4ry -ASCE 7-05,140 mph, Enclosed, Cat II, Exp B, I=1.0, Kzt=1.0 4y� Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0 1E ���• a a� VG • �1 1r • (A) (B)**) HMS WARN SH Ti s VD Fauly ALL haTcs RS Ttils raAt T � • aM4tTAMen ARND This BR NO 1 1D ALL ALL.DUS 11ac M DIST•' • -- --- TC LL 20 30 40 54 REF VALLEY FRAMING •• Trusses require extrene care in fabrlcotknp, hording, shippkng, InstnllUhr�pg and bracMp ' Refee 11 �kn.; follow the latest edition of BCSI (&Ackp component Safety Infornatlon,'i�y TPI SBW y 76 C TC DL and foCsSfatTir practices prior to perfarnkq these functions. Installers shwa provide temporary bmcJng peg SCSI. Unless noted otherwise' Sop chord shalt have property attached structural sheathing and bol n ciomd STATE OF 10 20 7 7 DATE 10/01/14 DRWG VACNVIS01015 r1� Q shall have a property attached Hold ceKinp. Locations shown fr permanent lateral restrnFit+SF • as unlessble. Apply proles to encS; stall have braposi installed per aboBCSve sections on the J r Details, of truss and position as shown above and an SM Joint Detals, unless Hated otherwise. ; Q a; A �� : BC DL 0 0 0 0 Iillll�\\VVI II ��1� Refer to drawkgs 160A-Z for standard plate poshtlons. ��V. T `i� ••• < O R 1OP••• D BC LL 0 0 0 0 Alpkne a division of ITV Building Conponents Group Inc. shnx not be responsible far ary devl tloMj \�+�\,`- ••• Ml RW ODMPANY this aro.I g arty falure to build She truss h conformance with AasvTri t, r for harnd9t p, Stipp •r'e•• l\ TOT. LD.30 50 47 61 Installation t bracing of trusses. A." an this dmwlp r cover, page Dstkp this drawkQ, indicates acceptance of professional e��er� solely fr the design shown ltr this dro.Inp \\a �iONAt •� DUR. FAC. 1.25/1.15 wltaHtty and use of fr- stray ucMre h. responsbsh, iavdro nper ANS[/iPi t s.c2 \q\ 13389 Lakefront Drive Earth City, MO 63045 For none knfornatlon see this ;Job's general notes page and these web It— inLPM m Ipinehw.com0 TFA •ew.tpklslarg, SEM www.sbchdustry.rg, ICD .ww.irsafearg S (� 6[ SPACING SEE ABOVE