HomeMy WebLinkAboutTrussI --j-
14, 4r,
io
6' 6"
1
n r
r
ci m
4 D
1'-a it
zrc
xo^
1'-1F11na"TYP.
MAY VARY
ZO O.C. Win
TO ODD SPACE
r`
8D
LO
6-3/16"
TRUSS HEEL.
TYPICAL CORNER SET
TRUSS LABELS WILL VARY
Hatch Legend
9'-411 BR(3% WALL
11'-4" BRIG WALL
TREY TO 101-411
24"
TRUSS END DETAIL
SCALE N.T.S,
NOTE: TRUSS END DETAIL REFLECTS DEFINED
MESUREMENTS AND APPLICATIONS TO
THE STRUCTURE; IT DOES NOT REFLECT
SUB-FACIAAND OR ANYSUPERFICIAL
REQUIREMENTS.
LUMBER E .,� TC
"`Signature of this document acknowedges that the client has reviewed this truss placement diagram
in its entirety and is in agreement with the following items, including but not limited to:
A.) The client is responsible to verify the accuracy of information submitted for use in design,
fabrication, and scheduling. Any labor, material, or time delay incurred fmm inadequate or incorrect
information supplied from the client will be at the client's expense.
B.) Design Criteria: The client acknowledges that the truss design criteria noted on this tress
placement diagram meets or exceeds the design criteria specified by the building designer, engineer of
record, and local and state building requirements.
C.) Fabrication and Delivery: One approved truss placement diagram must be returned to the truss
manufacturer before fabrication and delivery will be scheduled. It is the client's responsibility to
coordinate delivery dates with flee truss manufacturer. The client shall provide a marked location for
w delivery, which must be accessible, level, and clear of material and debris, in lieu of this, trusses will be
0 delivered in the best available location atour drivers discretion. Care and handling of the trusses
z following dilvery is the responsibilty of the client
0
gD.) Installation &Bracing; BCS12ODB) Buiding Component Safety Information) WTCA/TPI
J guidelines shall be followed when handling, installing, and bracing trusses. Temporaryaml/or
permanent bracingand blocking is not included in the truss package. Trusses shall be braced to
? prevent rotation and provide lateral stability in accordance with the requirements specified in the
construction documents for the building and on the individual truss design drawings. Theoverall
stability of the truss system is the responsibility of the building designer.
To) Field framing:1.) Tray ceilings and other ceiling transitions may require field framing by others.
2.) Ceiling drops and valleys not shown are to be field framed by others. 3.) Overhangs may beaver
length -cutto fit infield. 04ethangsam2x4mZx6-noblockingisappiied. Comer jacks will be
square cat and hip jacks will be double beveled.
F.) Repairs: Truss related problems anew be reported to the trussmanufacturer ASAP, preferably
in writing. DO NOT CUT ANY TRUSSES before conWaing the truss manufacturer with specifics of the
problem. Any field modifications made without an engineered repair drawing will be the responsibility
of the client. No back charges or crane charges of any kindwill be ampeted, unless specifically
approved in writing by the truss manufacturer's management.
G.) This Truss Placement diagram was not created by an engineer, rather by Tibbetts Lumber Co,
tLC staff, and is purely to be used as an installation guide and does not requires seal. Trussdeisgn
analysis are on the Truss Design Drawings which maybe sealed bythe Tress Design Engineer.
OF F`
FILE COPY
SFiNARD jp �9
AROOIS19
u, 3 r
z
W
Floor Load;
Roof L08Q
._# psi, _. TCLL, ...
TCDL, ... BCLL, ... BCDL; Duc:...
37# psi, 20 MILL, 7 TCDL, 0 BCLL, 10 BCOL; Dur.: 1.33
Design checked for 10 psi non -concurrent LL on BC.
Design Checked for 10 psf non -concurrent LL on BC.
Mgek Engineering 8.2.1.267
Exposure : C
Building Code
FBC 2017
Mean Hgt. : 15'
ASCE 7-10
Bldg. Cat. r II
TPt 1-2014
Importance Factor : C
S
Tress Design
: C & C
Enclosure : Enclosed
Uplift CaIc.
: MWFRS
.Entry Exposed to Wind
W
Wind Speed
: 160 mph US
Lanai : Exposed to Wind
g
ROOF CRITERIA
FLOOR CRITERIA
w
T.C. Pitch
5 / 12
B.C. Pitch
TREY / 12
Depth ...
u
T.C. Size
2X4
Spacing 24"
Heel Hgt.
4-1116"
Bearing
W,
Cantilever
24"
Vapor harder between floor & concrete by others.
Overhang
-
Floor trusses had back 3/4" at exterior walls,
block & fill by others. Blocking for vertical load transfer
Spacing
24" o.c.
by others.
Odd space Boor trusses around plumbing as noted
J
a
a Approved by:
a
WW Desired delivery date
Approval Date:
Date, Intials, Description
BUILDING
W
:i Project
RUDY'S COURTYARD
Address: ... _....__ _...- _.
Date : 1l2l2019 Designer : OMD
Project # 506926
i
Lumber design values are in accords , ce with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
MiTek®
RE: 506926 - Gopher Ridge Courtyard
!
p g y MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
mpa, FL 33610-4115
Customer Info: Rudy Vega Project Name: Gopher Ridge Courtyard Residence ModTe .
Lot/Block: Subdivision:
Address: 960 Gopher Dr
City: Fort Pierce State: Florida
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 2I0/20 8.2
Wind Code: ASCE 7-10 Wind Speed: 160 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 55 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
No.
Seal#
Truss Name
Date
11
IT15924348
1A1
1/3/19
118
IT15924365
CA _
1/3/19
12
IT15924349
IA2
1113/19
119
IT15924366
CAP
11/3/19
3
IT15924350
IA3
1/3/19
120
IT15924367
ICJ3
11/3/19
14
IT15924351
JA4
11/3/19
121
IT15924368
ICJ5
11/3/119 I
15
IT15924352
JA5
11/3/19
122
IT15924369
ID1
11/3/19
16
IT15924353
JA6
11/3/19
123
IT15924370
ID2
11/3/19
17
IT15924354
JA7
11/3/19
124
IT15924371
ID3
11/3/19
18
IT15924355
1B1
11/3/19
125
IT15924372
IN
1113/19
19
IT15924356
JB2
11/3/19
126
IT15924373
ID5
1/3/19
110
IT15924357
163
11/3/19
127
IT15924374
JD6
1/3/19 I
I11
IT15924358
IB4
11/3/19
128
IT15924375
JD7
1/3/19
112
IT15924359
165
11/3/19
129
IT15924376
JD8
11/3/19
113
IT15924360
JB6
11/3/19
130
IT15924377
ID9
1113/19 I
114
IT15924361
I B7
11/3/19
131
IT15924378
I D10
11/3/19 1
115
IT15924362
I B8
11/3/19
132
IT15924379
I D 11
11/3/19 1
116
JT15924363
1139
11/3/19
133
IT15924380
ID12
11/3/19 J
117
IT15924364
B10
11/3/19
134
IT15924381
ID13
11/3/19 1
The truss drawing(s) referenced above have been prepared by MiTek
USA, Inc. under my direct supervision based on the parameters
provided by Tibbetts Lumber Company -Palm Bay.
Truss Design Engineer's Name: ORegan, Philip
My license renewal date for the state of Florida is February 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSIfrPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MITek's customers
file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSUTPI 11, Chapter .
FILE COPY
W
OF FLO��O
OPAD ,/ONE 9
AR0015193 ;
V
ED ARC��C
I3 O'A����ii
`INV\' C E N S+
No 581.26
� r
��: STA. E OF :��/Z
.•
0NAI-E �``•
� �I/lllllll�
Philip J. O'Regan PE Nc.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
OR gan, Philip 1 of 2
W1 a
MiTek a
MiTek USA, Inc.
RE: 506926 - Gopher Ridge, Courtyard 6904 Parke East Blvd.
Tampa, FL'33610-4115
Site Information:
Customer Info: Rudy Vega Project Name: Gopher Ridge Courtyard Residence Model:
Lot/Block: Subdivision:
Address: 960 Gopher Dr
City: Fort Pierce State: Florida
No.
Seal#
(Truss Name
Date
135
IT15924382
ID14
1/3/19
36
IT15924383
I D15
11/3/19
137
I T15924384
l E 1
11/3/19
138
IT15924385
JE2
11/3/19
139
IT15924386
JE3
11/3/19
140
IT15924387
JE4
11/3/19 1
141
IT15924388
JE5
11/3/19
142
IT15924389
JEJ1
11/3/19 1
143
IT15924390
I EJ2
11/3/19
144
IT15924391
JEJ3
11/3/19
145
IT15924392
JEJ4
11/3/19
146
IT15924393
JEJ5
11/3/19
147
IT15924394
JHJ1
11/3/19
148
IT15924395
JHJ2
11/3/19
149
IT15924396
JHJ3
11/3/19 1
LO
IT15924397
JV1
11/3/19
151
IT15924398
IV2
11/3/19
152
IT15924399
IV3
11/3/19
153
IT15924400
IV4
11/3/19
154
IT15924401
IV5
11/3/19
155
IT15924402
IV6
11/3/19
2 of 2
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924348
506926
Al
Common Girder
1
n
L
Job Reference (optional)
I IDDeUS LUMDer G0, vaim uay, , rL 6.240 s Uec 8 2018 MITek Industries, Inc. Wed Jan 2 15:12:13 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-K59VWiu5je85DkkSrNR94Sj2QM8Azs6U5m1 UVhzzMFG
6-7-3 12-8-10 18-rr0 23.0.3 23r10-1,3 29 3-11 350.0
E7-3 5-11-6 5.11-6 4-6-3 0. 0.1 5-4-13 5$5
6x6 11
S nn Fig
Scale = 1:62.2
NOM STP = 7x8 = 8x14 MT20HS = NOP2X STP = 7x8 = 2x4 11
44 = 6x6 =
7x8 =
IN
2�0.02-$13 9.2-10 16-1.6 23.0.3 29-8-11
350.0
2-0.00. 3 rr10.13 6.10.13 Cr10.13 6-38
SB-5
Plate Offsets (X,Y)-
[1:0-2-0,Edge], [3:0-2-12,0-3-01, [10:0-4-0,0-4-81, [11:0-4-0,0-4-41, [12:0-7-0,0-4-81, [13:0-4-0,0-4-121, [14:0-3-0,0-4-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in floc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL) -0.13 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.61
Vert(CT) -0.25 12-13 >999 240
MT20HS 187/143
BCLL 0.0
Rep Stress Incr NO
WB 0.83
Horz(CT) 0.04 11 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wtnd(LL) 0.19 12-13 >999 240
Weight: 449lb FIT =20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-1 oc purlins,
BOT CHORD 2x6 SP DSS -Except' except end verticals.
9-10: 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing, Except:
WEBS 2x4 SP No.2 *Except* 6-0-0 cc bracing: 10-11.
8-9: 2x6 SP No.2 WEBS 1 Row at midpt 5-11
REACTIONS. (lb/size) 11=7513/0-7-10, 14=5549/0-7-10, 9=336/0-6.0
Max Horz 14=262(LC 24)
Max Uplift 11=3916(LC 8), 14=2923(LC 8). 9=601(LC 25)
Max Grav 11=7513(LC 1), 14=5553(LC 17), 9=344(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2105/1140, 2-3=-2079/1127, 3-4=7644/3702, 4-5=3991/1975, 5-6=605/1440,
6-7=-747/1470, 7-8=-607/1226, 8-9=385/625
BOT CHORD 1-14=-1009/1885, 13-14=3107/6477, 12-13=2289/5023, 11-12=839/1773,
10-11=-1116/535
WEBS 3-13=-489/849, 4-13=-1776/3668, 4-12=2476/1375, 5-12=2996/6209, 5-11= 6027/2938,
6-11=-356/317, 7-11=-404/685, 3-14=5447/2592, 2-14=267/302, 8-10=1164/505
NOTES-
`�I
1) 2-ply truss to be connected together with 1 Od (0.131"x3") nails as follows:
�% \Q 3 • 0 /��. �I♦♦
Top chords connected as follows: 2x4 - 1 row at 0-9-0 cc, 2x6 - 2 rows staggered at 0-9-0 oc.
��•.
�Q�\ �• G E N • �'9jL♦♦
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc.
•• \ S'
; ♦0
Webs connected as follows: 2x4 -1 row at 0-9-0 cc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
♦
No 58126
•�
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
* �'
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=35ft; eave=5ft; Cat.
•�
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plate
grip DOL=1.60o
p •� S F :
5) All plates are MT20 plates unless otherwise indicated.
♦O�� • Q;•
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
O R ` \���
♦♦j • C%
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0=0 wide
s ��
l fit between the bottom chord and any other
ro
8) Provide de mechanical connection (by others) truss bearing plate capable of withstanding 100 lb uplift atjoint(s) except at=1b)
11=3916, 14=2923, 9=601.
.581 26
Philip J. O'Rejlarl PE NoNoCent 581
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 912 lb down and 651 lb up at
MRek USA, Inc, FL 6634
3-6-12, 1029 lb down and 496 lb up at 5-6-12, 1029 lb down and 500 lb up at 7-6-12, 1029 lb down and 506 lb up at 9-6-12, 1029
6904 Parke East Blvd. Tampa FL 33610
lb down and 513 lb up at 11-6-12, 1029 lb down and 521 lb up at 13-6-12, 1054 lb down and 535 lb up at 15-6-12, 1034 lb, down
Data:
and 526 lb up at 17-6-12, and 1034 lb down and 473 lb up at 19-7-4, and 1031 lb down and 479 lb up at 21-7-4 on bottom, chord.
January 3,2019
ry
The design/selection of such connection device(s) is the responsibility of others.
AWARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED 69TEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon paremeters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing.
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
WOW
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1nP/1 quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924348
506926
Al
Common Girder
1
n
L
Job Reference (optional)
i iuueua 1-1— w, reran ody , rL t5.Z4D S Ueci b zui t1 MI I eK moustrles, Inc. vve0 Jan z 1 b:12:13 zu19 Page 2
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-K59VWiu5je85DkkSrNR94Sj2QM8Azs6U5m1 UVhzzMFG
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=54, 5-8=54, 1-9=20.
Concentrated Loads (lb)
Vert: 17=854(B) 18=1029(13) 19=1029(B) 20=1029(13) 21=1029(B) 22=1029(131) 23=-1054(B) 24=-1034(B) 25=-1034(B) 27=-1031(B)
A WARNING -Verify design parameters and READ NOTES ON MIS AND INCLUDED M1TEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. '
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANShTP1I quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924349
506926
A2
Common
3
1
Job Reference (optional)
Tibbetts Lumber co, Palm Say, FL Run: 8.240 s Dec 6 2018 Print: 8i240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:36 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-CeeuCLHQF5snosAxChuXfVw2uch4nQUA8Ce?VDzzM?v
6-7-3 12.0-10 18.6.0 23-0.3 1 30-4-13 37-0-0
6-7-3 511-0 Sit-6 4.6-3 7-4-10 0.7-3
Scale = 1:61.0
5x6 =
NOP2X STP = 3x4 = 5x6 = NOP2X STP = 5x6 = 3x4 = 3x6 =
3x6 = 3x4 =
6x6 =
2e-10-10
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL) -0.09 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.42
Vert(CT) -0.13 12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.96
Horz(CT) 0.02 12 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL) 0.07 11-12 >999 240
Weight: 204lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied
or 6-0-0 oc bracing.
WEBS 2x4 SP No.2 WEBS 1 Row at midpt
5-12
REACTIONS. (Ib/size) 12=1498/0-7-10, 15=830/0-7-10, 10=410/0-6-0
Max Horz 15=283(LC 11)
Max Uplift 12=-979(LC 12), 15=-436(LC 12), 10=357(LC 12)
Max Grav 12=1498(LC 1), 15=841(LC 21), 10=470(LC 22)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=296/87, 3-4=835/345, 4-23=-423/229, 5-23=-365/246, 5-24=-90/426, 6-24=93/341,
6-7=178/383
BOT CHORD 1-15=51/289, 14-15=216/975, 13-14=78/754, 13-26=59/260, 26-27=59/260,
12-27=591260, 11-12=365/501
WEBS 4-14=55/291, 4-13=525/421, 5-13=256/678, 5-12=977/514, 6-12=567/757,
6-11=806/501, 7-11=331/296, 3-15=944/562, 2-15=192/298, 7-10=381/452
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
�� 0, It..
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-8-6, Interior(1) 3-8-6 to 18-6-0, Exterior(2) 18-6-0 to
........
�\ • • • • • • �♦
22-2-6, Interior 1 22-2-6 to 37-0-0 zone; cantilever left and right exposed ; porch right ex osed;C-C for members and forces &
MWFRS for Lumber DOL=1.60 DOL=1.60
�% : •'
•C SF ' ♦i
reactions shown; plate grip
3) All plates are MT20 plates unless otherwise indicated.
�2
♦♦
No 58126
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 979 lb uplift at joint 12, 436 lb uplift at
-p ;
joint 15 and 357 lb uplift at joint 10.
:• S (V
•
♦�T�S.�pR`�P��Z,.
11110,
Philip J. D'Regan PE No.58126
MITek USA, Inc. Fl. Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MI-7473 rev. 101032015 BEFORE USE
Design valid for use only with MiTeM connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
��•
a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design into the overall;
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Mel(Is
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabdcatlon, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/1 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safely Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
�Qty
T15924350
506926
A3
Hip
1
1
Job Reference (optional)
Lumber Cu, rain, Say, FL Run: 8.240 s Dec 6 2018 Print: 8240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:28:37 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-ggCGQhl2OP_eQO171PPmCiTBLOxIWwrJMsOY1 fzzM7u
2-3-13 8.1.3 11-B-10 17.0-0 20.0.0 23-0.3 30.10.13 34-9-0 37.0.0
2-3-13 3.9.8 5.5.8 5-5-6 3-0-0 3.0-3 7-10.10 3-10.3 2-3-0
5x6 =
5x6 =
s nn
Scale = 1:63.1
NOP2X STP = 5x6 = 3x4 = 6x6 = NOP2X STP = 3x4 = 3x4 = 3x6 =
3x6 = 4x4 = 2x4 II
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.63
BC 0.80
WB 0.76
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl L/d
-0.18 15-16 >999 360
-0.40 15-16 >628 240
0.06 11 n/a n/a
0.26 15-16 >954 240
PLATES GRIP
MT20 244/190
Weight: 208 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, except
BOT CHORD 2x4 SP No.2
2-0-0 oq purlins (5-8-4 max.): 5-6.
WEBS 2x4 SP No.2
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 13=548/0-7-10, 17=1174/0-7-'10, 11=1017/0-6-0
Max Horz 17=-260(LC 10)
Max Uplift 13=514(LC 12), 17=605(LC 12), 11=653(LC 12)
Max Grav 13=644(LC 22), 17=1175(LC 21), 11=1017(LC 1)
FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=307/95, 3-4=1558/885, 4-5=-1123/774, 5-6=-998/784, 6-7=-11101835,
7-25=1067/1169, 8-25=1186/1156
BOT CHORD 1-17=57/299, 16-17=632/1471, 15-16=661/1494, 14-15=355/1098, 13-14=382/1013,
12-13=382/1013, 11-12=-876/1063
WEBS 4-15=532/406, 5-15=63/302, 7-13=597/709, 7-12=-639/321, 3-17=1547/1036,
2-17=197/292, 8-11=1396/1265
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
RS directional) and C-C to
,%!0,
R�
37 zone; t
�
cantilever left and rriight(exposed parch right exposed C C far memberseand(forces &
25-2-13, Interilor(1) 25-2 13 to 0-0
MWFRS for Lumber DOL=1.60 DOL=1.60
,�NV G E N
•'• S' •••' �i
2
reactions shown; plate grip
��
3) Provide adequate drainage to prevent water ponding.
i
NO 58126
•;
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
* ,
6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
=
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
-p ;
•(V
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 514 lb uplift at joint 13, 605 lb uplift at
ST
joint 17 and 653 lb uplift at joint 11.
8) Graphical does depict the the the the top bottom
i�,T ••: :
purlin representation not size or orientation of purlin along and/or chord.
O P ��,��
AIts
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Gert 66M
69M Parke fast Blvd. Tampa FL 33610
Date:
January 3,2019
,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MnEK REFERENCE PAGE MI.7473 rev. 1"3,2015 BEFORE USE
Design valid for use only with M7ek0 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty,
Ply
Gopher Rmge courtyard
T15924351
506926
A4
Hip
1
1
Job Reference optional)
Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:38 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-811fdOJgni6V2AKJJ6w?Iw01bQLOFNRTbW76Z5zzM?t
7-9-14 15-0-0 22-0-0 28-4-2 2 -2- 37-0-0
7-9-14 0-1 64-1 7-0-0 6-0-2 0.1 7-9-14
Scale = 1:62.0
Sx8 =
5x6 =
3x6 = 3x6 11 04 = 5x6 = 5x8 = 4x4 = NOP2X STP =
3x6 11 3x6 =
NOP2X STP =
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) ' I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL) -0.11 11-12 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.23 11-12 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.74
Horz(CT) 0.05 9 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL) 0.13 11 >999 240
Weight: 197lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-13 oc purlins, except
BOT CHORD 2x4 SP No.2 2-0-0 oc purlins (2-11-6 max.): 4-5.
WEBS 2x4 SP No.2 BOT CHORD Rigid calling directly applied or 6-2-0 oc bracing.
WEBS 1 Rowe t midpt
4-11
REACTIONS. (lb/size) 14=1369/0-7-10, 9=1369/0-7-10
Max Horz 14=-230(LC 10)
Max Uplift 14=-707(LC 12), 9=611(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-21 =1 890/1088, 3-21=-1825/1107, 3-22=1660/1064, 4-22=1591/1082, 4-23=1469/1086,
23-24=1469/1086, 5-24=1469/1086, 5-25=-1589/1081, 6-25=1658/1063,
6-26=1825/1107,7-26=-1890/1088
BOT CHORD 13-14=194/335, 12-13=906/1794, 12-27=-704/1517, 11-27=704/1517, 10-11=891/1685
WEBS 3-13=142/251, 3-12=319/233, 4-12=39/371, 5-11=-46/357, 6-11=-328/233,
6-10=141/251, 2-13=1045/1652, 2-14=-1246/980, 7-10=1044/1652, 7-9=1247/980
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
�1111111�
20 2-13, Interlor(1) 20-2-13 22 0-0 (directional)and C-C riorl 3-8-6 0-0 to
Etxte 0r(1) ands
\Q J o r&
to or(2))22-0; 0 t 27-2-13, In er oteriori
27-2-13 t 37 0 0 zone; cantilevereft right
,,,��
����
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide drainage to
�� •r\\ ;•� G ENS ••�-9
Q �`••
adequate prevent water ponding.
�, �2.
4) All plates are MT20 plates unless otherwise indicated.
i
NO 58126
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide
mechanical connection (by others) of truss to bearing plate capable of withstanding 707 lb uplift at joint 14 and 611 lb uplift at
-p ;
•ICJ
joint 9.
8) Graphical purin representation does not depict the size or the orientation of the along the top and/or bottom chord.
: O F :
(V
purlin
�/lnnn�
Philip J. 6'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED It9TEK REFERENCE PAGE 0I-7473 rev. 10/03/2016 BEFORE USE �--
�'
Design valid for use only with MTekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI! Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
city,
Ply I
Gopher Ridge Courtyard
T16924352
506926
AS
Hip
1
1
Job Reference (optional)
Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8;240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:28:39 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-cDJ1 gMKIYOELfKvV%gREH7YZ?pjQ_tncgAtf6YzzM?s
6-9-14 7 7-1 13.0-0 18-8-0 N- -0 29-4 1 3 -2- 37-0-0
6-9-14 0-10- 5-0-2 5-0-0 5-6-0 5-0-2 0-1 6-9-14
Scale = 1:62.0
5x8 =
2x4 11 5x8 —
Io.
3x6 = 3x6 11 44 = 5x6 = 3x8 = 5x6 = 4x4 = NOP2X STP =
3x6 11 3x6 =
NOP2X STP =
2� -0-0 2 13 7-7-14 13-0-0 18-6-0 24-0-0 29-0-2 34-83 337-0-0
2-0-0 0 13 SJI-2 5d-2 5-6-0 5A0 Say s.dN _1w, r��
Plate Offsets.(X,Y)—
[1:0-0-14 0-0-2][4:0-5-12,0-2-8],[6:0-5-12,0-2-8] [12:0-3-0 0-3-0],[14:0-3-0 0-3-0]
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in floc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.49
Vert(LL) -0.11 13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.44
Vert(CT) -0.20 13-14 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.54
Horz(CT) 0.06 10 ! n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL) 0.14 13 >999 240
Weight: 202 Ito FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 16=1369/0-7-10, 10=136910-7-10
Max Horz 16=-199(LC 10)
Max Uplift 16=-707(LC 12), 10=611(LC 12)
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-1-11 oc purlins, except
2-0-0 oc purlins (4-1-11 max.): 4-6.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-23=1833/1081, 3-23=-1777/1097, 3-4=-174611134, 4-24=1774/1233, 5-24=1774/1233,
5-25=1774/1233, 6-25=-1774/1233, 6-7=-1746/1134, 7-26=1777/1097, 8-26=1833/1081
BOT CHORD 15-16=176/266, 14-15=-910/1662, 13.14=-782/1555, 12-13=766/1555, 11-12=894/1641.
WEBS 3-15=216/280, 4-14=20/254, 4-13=-239/413, 5-13=-336/353, 6-13=239/413,
6-12=20/254, 7711=216/280, 2-15=-1079/1670, 2-16=-1251/958, 8-11 =11 07911670,
8-10=1251/959
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; ea've=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-8-6, Interior(1) 3-8-6 to 13-0-0, Exterior(2) 13-0-0 to
18-6-0, Interior(1) 18-6-0 to 24-0-0, Exterior(2) 24-0-0 to 29-4-2, Interior(1) 29-4-2 to 37-0-0 zone; cantilever left and right exposed
;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members. 1
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 707 lb uplift at joint 16 and 611 lb uplift at
joint 10.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord:
,&WARNING -Vedly design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not I
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall,
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPif Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. I
`,�II111111►j�
No 58126
' OF k/
N A'00
Philip J. O'Regan PE No.58126
MIT& USA, Inc, FL Gert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MF
MiTek°
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
506926
A6
Hip
1
i
T15924353
Job Reference (optional)
--"'--' -•' """ ""J , • Run: o. 5 uec o zuio rnm: o.z4u s uec its zu16 rim I ek industries, Inc. Wed Jan 2 16:28:39 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZMcDJ1 gMKIYOELfKvmgREH7YTrpfN_uUcgAtf6YzzM7s
11-0-0 18-6-0 P6-0-0 37-0-0
11-M 7.6-0 7�6-0 11-0-0
rrIA
3x6 =
NOP2X STP =
5x8 = 2x4 II 5x8 =
5x6 =
3x8 =
5x6 =
Scale = 1:62.0
v
7 jV
0
NOM STP =
3x6 I I 3x6 =
2-0-0 U13 it-" 18E-0 26-0-0 34-8-3 35,0,0 37-0-0
2-0-0 0�-
Plate Offsets (X,Y)—
[1:0-0-14,0-0-21,13:0.5-4 0-2-4],[5:0-5-4,0-2-4],19:0-3-0 0-3-01[11:0-3-0 0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.88
Vert(LL)
-0.12
10
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.70
Vert(CT)
-0.25
8-9
>999
240
BCLL 0.0
Rep Stress ]nor YES
WB 0.49
Horz(CT)
0.05
8
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.16
10
>999
240
Weight: 185 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP SS *Except* TOP CHORD
3-5: 2x4 SP No.2
BOT CHORD 2x4 SP No.2 BOT CHORD
WEBS 2x4 SP No.2 WEBS
REACTIONS. (lb/size) 12=1369/0-7-10, 8=1369/0-7-10
Max Harz 12=169(LC 11)
Max Uplift 12=-707(LC 12), 8=611(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=339/83, 2-19=1896/1090, 19-20=-1825/1098, 3.20=-1796/1115, 3-21=2129/1402,
21-22=2129/1402, 4-22=-2129/1402, 4-23=-212911402, 23-24=2129/1402,
5-24=2129/1402, 5-25=-1796/1115, 25-26=1825/1098, 6-26=1896/1090, 6-7=344/142
BOT CHORD 1-12=147/377, 11-12=179/503, 10-11=848/1657, 9-10=-833/1657, 8-9=185/381,
7-8=185/381
WEBS 2-11=794/1371, 3-10=3B2/659, 4-10=-455/448, 5-10=-382/659, 6-9=795/1371,
2-12=1246/1095, 6-8=1246/1095
Structural wood sheathing directly applied or 4-2-4 oc purlins, except
2-0-0 oc purlins (2-2-0 max.): 3-5.
Rigid ceiling directly applied or 6-4-3 oc bracing.
1 Row at midpt 2-11, 6-9
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2), Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eeve=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0.0 to 3-8-6, Interior(1) 3-8-6 to 11-0-0, Exterior(2) 11-0-0 to
16-2-13, Interior(1) 16-2-13 to 26-0-0, Exterior(2) 26-0-0 to 31-2-13, Interior(1) 31-2-13 to 37-0-0 zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 707 Ib uplift at joint 12 and 611 lb uplift at
joint 8.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
,&WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED mnrEK REFERENCE PAGE iWI-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall[
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
%%%% �IIIJ110'1j
i
No 58126
00•
///1111111
Philip J. VRegan PE No.58126
MlTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTOW
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924354
506926
A7
Hip Girder
1
t
]Job
Reference (optional)
6um—a —.1 ody , FL nun: b.z4u s use b zu18 vent: 8.24u s Dec 18 2018 MITeK Industries, Inc. Wed Jan 2 16:28:41 2019 Pagel
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-ZcRnF2LY4dU3vd3u_FUiMYerbdM_SmVvHUMmAQzzM?q
i Na
15-0-9 21-7-7 28-0-0 37-0-0
9-0 6-4-9 6-2-13 6-4-9 9-0-0
6x6 =
5.00 12
2x4 11 7x8 =
5x6 =
3x6 II �� �" --m a co za su s1
3x6 = 4x6 = 5x8 = 2x4 11 6x8 = NOP2X STP =
NOP2X STP =
THIS TRUSS IS NOT SYMMETRIC.
PROPER ORIENTATION IS ESSENTIAL.
Scale = 1:62.0
2x4 11 3x6 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.74
BC 0.56
WB 0.59
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl L/d
-0.18 11-12 >999 360
-0.40 11-12 >977 240
0.08 9 n/a n/a
0.23 11-12 >999 240
PLATES. GRIP
MT20 244/190
Weight: 201 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 2-9-15 oc purlins, except
3-5,5-6: 2x6 SP No.2
2-0-0 od purlins (3-8-8 max.): 3-6.
BOT CHORD 2x4 SP SS *Except*
BOT CHORD
Rigid ceiling directly applied or 6-6-15 oc bracing.
8-10: 2x4 SP No.2
WEBS
1 Row at midpt 5-10
WEBS t 2x4 SP No.2
REACTIONS. (lb/size) 14=177910-7-10, 9=1777/0-7-10
Max Horz 14=-138(LC 6)
Max Uplift 14=-796(LC 8), 9=699(LC 8)
Max Grav 14=1787(LC 29), 9=1784(LC 30)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2786/986, 3-21=3585/1234, 4-21=-3585/1233, 4-5=-3584/1231, 5-22=2539/988,
6-22=2539/989, 6-7=2794/1009
BOT CHORD 13-14=131/313, 13-23=-771/2579, 23-24=771/2579, 24-25=771/2579, 12-25=771/2579,
12-26=1042/3596, 26-27=-1042/3596, 27-28=-1042/3596, 11-28=1042/3596,
11-29=1042/3596, 29-30=-1042/3596, 30-31=-1042/3596, 10-31=1042/3596
WEBS 3-13=125/389, 3-12=306/1382, 4-12=-405/304, 5-11=0/496, 5-1 0=-1 3591292,
6-10=71/788, 2-14=1723/844, 7-9=-1715/793, 2-13=-784/2374, 7-10=723/2388
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 796 lb uplift at joint 14 and 699 lb uplift at
joint 9.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection,device(s) shall be provided sufficient to support concentrated load(s) 72 lb down and 146 lb up at
9-0-0, and 72 lb down and 146 lb up at 28-0-0 on top chord, and 331 lb down and 144 lb up at 9-0-0, 69 lb down at 11-0-12, 69 lb
down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 18-6-0, 69 lb down at 19-11-4, 69 lb down at
21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 331 lb down and 144 lb up at 27-11-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8).
&WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED NI TFK REFERENCE PAGE 6e1.7473 rev. 1010312015 BEFORE USE
Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
t%J1111111/1I
F• 00
No 58126
OF 4U
i,41S10 N A; EC,%%%
Philip J. Q'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
M!Tek"
6904 Parke East Blvd.
Tampa, FL 36810
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
506926
A7
Hip Girder
1
1�
T15924354
Job Reference (optional)
IpOu]aICS, me. " -Jan Z lO:L6:91 Zulu rageL
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-2cRnF2LY4dU3vd3u_FUiMYerbdM_SmVVHUMmAQzzM?q
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-6=-54, 6-8=-54, 15-18=-20
Concentrated Loads (lb)
Vert: 3=-44(F) 6=-44(F) 13=-172(F) 10=-172(F) 23=-43(F) 24=-43(F) 25=-43(F) 26=-43(F) 27=-43(F) 28=-43(1=) 29=43(F) 30=-43(F) 31=-43(F)
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 08TEK REFERENCE PAGE M11-7473 rev. 10/03,2015 BEFORE USE.
Design valid for use only with MrrekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not I
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overalll
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply 1
Gopher Ridge Courtyard
T15924355
506926
B1
Roof Special
1
1
I
Job Reference (optional)
����_� ��, ������ o•r r� mun: 8.24u s uec b 2uiu vnnt: 8.24u s uec m 2u16 MITek industries, Inc. wed Jan 2 16:28:43 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-V ZYgkNpcFknBxDH6fWASzjFARzewfdClortFJzZM?o
5-10-5 11-5-3-13 17-0-0 22-3-6 27-6-12 32-4-11 37.-0
5-10.5 5.6 5.6.13 5.3.6 S•3$ 4-9.15 5.5
5.00 12 5x6 =
3x4
Scale = 1:67.1
NOP2X STP = 3x4 = 5x8 — 3x4 — 5x6 — 4x4 = NOP2X STP =
6x6 = 3x6 11 3x6 =
99-0�--99 177--7M-7 25-:135� 27 AA 12 a-S41 S1 3�5-a1-a3�,U�
Plate Offsets (X,Y)-
[3:0-3-0,0-3-0] [12:0-3-0,0-3-0] [14:0-4-0,0-3-0]
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL) -0.18 15-16 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.87
Vert(CT) -0.38 15-16 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.68
Horz(CT) 0.09 10 ri/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL) 0.17 13-14 >999 240
Weight: 213 lb FT = 20%
LUMBER- BRACING- i
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied
or 5-10-15 oc bracing.
1-16: 2x6 SP No.2 WEBS 1 Row at midpt
2-16
REACTIONS. (lb/size) 16=1280/0-7-10, 10=141710=7-10
Max Horz 16=-270(LC 38)
Max Uplift 16=-580(LC 12), 10=690(1_13 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-20=282/196, 2-3=2027/1162, 3-21=-1590/1016, 4-21=-1526/1028, 4-22=1526/1016,
5-22=1586/1001, 5-6=2010/1158, 6-7=-2200/1185, 7-23=-1514/827, 8-23=1565/819,
8-9=257/144, 1-16=246/255
BOT CHORD 15-16=939/1951, 15-24=-778/1806, 24-25=-778/1806, 14-25=778/1806, 13-14=813/1811,
12-13=989/2089, 11-12=-650/1380, 10-11=-1071265, 9-10=107/265
WEBS 3-15=321307, 3-14=595/378, 4-14=-488/906, 5-14=-647/424, 6-13=371/236,
6-12=224/272, 7-12=-498/786, 7-11=-555/346, 2-16=-1886/1039, 8-10=1314/917,
5-13=68/345, 8-11=941/1606
NOTES-
1) Unbalanced roof live loads have been considered for this design.
,,`IIIIIIIIIIIIII
��\p
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; ea've=5ft; Cat.
�V
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-2-12 to 3-11-10, Interior(1) 3-11-10 to 17-0-0, Exterior(2)
��, Q :
17-0-0 to 20-8-14, Interior(1) 20-8-14 to 37-4-15 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for
No 58126
•:
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
.'
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
-p ;
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
16 lb
F 4/1 Z
�• ((�
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 580 lb uplift at joint and 690 uplift at
joint 10.
.0
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 178 lb down and 135 lb up at
32-4-11 on top chord, and 13 lb down and 84 lb up at 32-4-11 on bottom chord. The design/selection of such connection device(s) is
�i�, S1 `: 0 fi •'•`��,��
�� s� • • •�`
the responsibility of others.
�IIIIQ N Al �%
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Philip J. O'Regan PE No.58126
LOAD CASE(S) Standard
MITek USA, Inc. FL Cert 6634
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
6904 Parke fast Blvd. Tampa FL 33610
Uniform Loads (pig
Date:
Vert: 1-4=-54, 4-6=-54, 6-7=-54, 7-9=54, 16-17-20
January 3,2019
Fold, � --
,AWARNING - Venry design parameters and READ NOTES ON THIS AND INCLUDED NI7EK REFERENCE PAGE M11.7477 rev. 101031201S BEFORE USE
Design valid for use only with MrrekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not' 's
a truss -system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSh7F11 Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T16924355
506926
81
Roof Special
1
1
Job Reference (optional)
-Pa
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 11 =55(F)
rcun: o.z s uec o zulo rnnC o.z4U s uec to zulc mi I eK Inausines, Inc, web Jan 2 1625:43 2019 Page 2
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-V ZYgkNpcFkn6xDH6fWASzjFARzewfdClortFJzzM?o
,& WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERENCE PAGEMI-7473 rev. 10M1,2018 BEFORE USE
r�
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
w-'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall'
building design. Bracing indicated is to prevent buckling of individual truss web antl/or chord members only. Additional temporary and pemnaneM bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/1 Quality Criteria, DSB-89 andBCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty,
Ply 11
Gopher Ridge Courtyard
T15924356
506926
B2
Roof Special
1
1
Job Reference (optional)
Tibbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industdes, Inc. Wed Jan 2 16:28:44 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-zB7wu4ORNYsem5nTgN1 P_BG04gKgf5QL_SaQnlzzM?n
5-1-5 11-5-3 17.0.0 23-0-9 27-10.8 32-3-13 37.5-0
0 $ 5-16 S-8-13 513 8-0.9 4-9-15 4.5.5 5-1-2
5.00 12
I
r 3.4
NOP2XSTP = 3x4 =
6x6 =
5x6 =
5x8 = 5x6, = 3x4 =
Scale = 1:67.1
NOP2XSTP =
6x6 = 3x6 =
Iq
0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL) -0.23 13-14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.82
Vert(CT) -0.44 13-14 >943 240
BCLL 0.0
Rep Stress Incr YES
WB 0.71
Horz(CT) 0.10 10 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wtnd(LL) 0.16 13-14 >999 240
Weight: 211 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
1-15: 2x6 SP No.2 WEBS 1 Row at midpt
2-15
REACTIONS. (lb/size) 15=1284/0-7-10, 10=1467/0-7-10
Max Horz 15=-270(LC 10)
Max Uplift 15=-577(LC 12), 10=-658(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2069/1189, 3-20=-1608/1003, 4-20=-1547/1019, 4-21=1547/994, 5-21=1609/982,
5-6=-1983/1130, 6-7=2034/1054, 8-9=-318/83, 1-15=-225/256
BOT CHORD 14-15=923/1996, 14-23=-778/1801, 23-24=-778/1801, 13-24=-778/1801, 12-13=-825/1865,
11-12=791/1831, 10-1.1=-653/1431, 9-10=-54/314
WEBS 3-14=65/317, 3-13=560/389, 4-13=-431/883, 5-13=-611/409, 7-11 =1 59/442,
2-15=1958/1002,7-10=-1881/1180
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
,0!��
��'9�,1��i
C-C Exterior(
rG •'
17-0-0 to20-8-14,Clntlerrior(1) 2D-8--114 to137-5-0 zlone; cantilever leftand
and right exposed-1C-C for members and forces & MWFRS for
Lumber DOL=1.60 DOL=1.60
��,,`r\�\Q
E N
Q : •�,� SF•••? �i�
reactions shown; plate grip
��
3) All plates are MT20 plates unless otherwise indicated.
No 58126
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6), Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 577 lb uplift at joint 15 and 658 lb uplift at
-p ;
joint 10.
�O: OF
•:�4U
��i
FS • O R 10 • C?N%
Vic%%%
Philip J. O'Regan PE No.58128
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
® WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE 11111-7477 rev. 10/01,2015 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
Indicated is to buckling individual truss and/or chord members only. Additional temporary and permanent bracing
MiT®k`
building design. Bracing prevent of web
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandda, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply 'Gopher
Ridge courtyard
T15924357
506926
B3
Roof Special Girder
1
1�
Job Reference (optional)
rooeas Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 216:28:47 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-Nmo2W5QJgTFDdYW2LVa6cpuxT2McsWPogPp404zzM?k
5-10.5 11-5-3 17.0-0 22-5-4 27-10-8 32-8-7 37-5.0
5-10-5 5-6-13 5-6-13 5-5-4 5-5-4 4- 7;s 4-8.8
5.00 12 5x6 =
Scale = 1:67.8
Iq
0
NOP2X STP = 3x4 = 5x6 = 5x8 = 3x4 — 4x4 =NOP2X STP =
6x6 = 2x4 II 3x6 =
37-1-0
7-2-0 14-1-0 20.11-12 27-10-8 32-8-7 35.1-3 3
7 2-4 - - 6-10-12 -- 6-10-12 - 6-10-12 4-9-15 2�-11 0- 3 2-0-0
Plate Offsets (X,Y)—
[3:0-3-0,0-3-0],[13:0-3-12,0-3-0] [14:0-3-0,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.46
Vert(LL) -0.17 13-14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.74
Vert(CT) -0.30 13-14 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.50
Horz(CT) 0.09 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL) 0.17 13 >999 240
Weight: 214 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.2 'Except'
1-16: 2x6 SP No.2
REACTIONS.
(lb/size) 16=1280/0-7-10, 10=1409/0-7-10
Max Horz 16=-270(LC 6)
Max Uplift 16=581(LC 8), 10=698(1_13 8)
Max Grav 16=1291(LC 36), 10=1409(LC 1)
BRACING -
TOP CHORD
Structurl I wood sheathing directly applied or 3-6-5 oc purlins, except
end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 2-16
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=265/155, 2-3=2087/1031, 3-4=-1771/967, 4-5=-1910/1058, 5-6=1976/994,
6-7=2219/1073, 7-8=1518/772
BOT CHORD 15-16=775/2056, 15-20=-664/1900, 20-21=-664/1900, 14-21=664/1900, 14-22=435/1460,
22-23=-435/1460, 13-23=-435/1460, 12-13=-890/2104, 11-12=611/1331
WEBS 3-14=458/339, 4-14=242/702, 4-13=-361/792, 5-13=-347/309, 6-13=396/241,
7-12=423/894, 7-11=612/285, 2-16=-1940/869, 8-1 0=-1 3061688, 8-11=751/1551
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=37ft; eave=5ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 581 lb uplift at joint 16 and 698 lb uplift at
joint 10.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 156 lb down and 88 Ib up at
32-8-7 on top chord, and 26 lb down and 100 lb up at 32-8-7 on bottom chord. The design/selection of such connection�device(s) is
the responsibility of others. i
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 4-6=-54, 6-7=-54, 7-9=-54, 16-17=20
Concentrated Loads (lb)
Vert: 11=63(B)
A WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE N01-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TFI1 OuaW Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Inslhute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
IJIIIOII'R,,,���
No 58126
•
t�411
11111 4
Philp J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MOW
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924358
506926
B4
Hip
1
1
Job Reference (optional)
Tibbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:49 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-KBwpxnRZC5VxssgRSwdahEzCar2jKOX47ilBSzzzM?i
5-7-11 1%.I1.14 16-4-2 17-7-14 25.2-3 32-8-7 34-6.7
5-7-11 5-4.3 5-4-3 1-3.13 7.6.4 7.8.4 1-10-0
4x6 =
44 _
4 5
3x4
Scale = 1:61.4
12
NOP2X STP = 3x4 = 5x6 = 4x4 = 4x4 —3x6 11
6x6 =
3x4 =
IN
34-6-7
8-3-13 17-7-14
W-3 32-8-7
346-1
B-3-13 8-0-5 1-3.13
76-0 764
1-9-to
0-06
Plate Offsets (X,Y)—
112:0-3-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in floc) Vdefl Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.80
Vert(LL)
-0.20 13-14 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.76
Vert(CT)
-0:35 13-14 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.59
Horz(CT)
0.09 9 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.18 11-12 >999 240
Weight: 200 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied, except end verticals, and
BOT CHORD 2x4 SP No.2
2-0-0 oclpurlins (4-8-10 max.): 4-5.
WEBS 2x4 SP No.2 `Except` BOT CHORD Rigid ceiling directly applied or 5-8-0 oc bracing.
1-15: 2x6 SP No.2 WEBS
1 Row ai midpt 6-12, 2-15
REACTIONS. (lb/size) 15=126410-7-10, 9=1264/0-10-1
Max Horz 15=-240(LC 10)
Max Uplift 15=-568(LC 12), 9=567(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=253/200, 2-3=2014/1192, 3-17=-1595/1054, 4-17=-1585/1071, 4-5=1423/1045,
5-18=1543/1048, 6-18=-1633/1026, 6-7=-2196/1239, 7-8=-1513/791, 8-9=1274/660
BOT CHORD 14-15=1003/1897, 14-19=-921/1751, 19-20=-921/1751, 13-20=921/1751,
12-13=644/1423, 11-12=-1033/1966, 10-11=-810/1532
WEBS 3-14=17/282, 3-13=562/395, 4-13=-288/460, 5-12=-183/371, 6-12=714/480,
6-11=0/268, 7-11=252/442, 7-10=743/543,2-15=-1889/1048,8-10=-849/1663
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=35ft; eave=4ft; Cat.
2 to
R���9
right and3forces
22-6 8 nteriolr(1G2216-8 to 344 1R zone; cantilever eft and ex2posed1 CtC for members & MWPRStforr�eactions
Lumber DOL=1.60 DOL=1.60
�`\P........
E IV
Q : • V\ SF•°• 2 �i
shown; plate grip
��,
3) Provide adequate drainage to prevent water ponding.
NO 58126
•.
4) All plates are MT20 plates unless otherwise indicated.
live loads.
* �r
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
,
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
�.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 568 lb uplift at joint 15 and 567 lb uplift at
9.
S OF
0 • �(/`�
joint
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord:
i
E��`
11111
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
69% Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,AWARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERENCE PAGE IWI.7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with Mi rek® connectors. This design is based only upon,paramelers shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall'
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiT®k°
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the ,
fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
Gopher Ridge Courtyard
506926
85
Roof Special
1
1
T15924359
Job Reference (optional)
a,,,, ay", Itun: 8.24U s use 8 2u18 Nnnt: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:50 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy7lZMoLUB87SCyOdoUOFdOdBpESWP1 FPg3njEMN1 k_PuM7h
7-0-12 14-6-0 14- 14 19-7-14 26-8-3 34-0-0
7.4-12 7-1 4 0-1- 4 50-0 7-0-5 7313
6x6 =
4x6 =
Scale = 1:61.6
NOP2X STP = 44 = 5x8 = 5x8 = 4x4 = NOP2X STP =
3x6 11
3x6 11
19-7-14
LOADING (psf)
TCLL 20.0
TCDL 7.0
BOLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.69
BC 0.65
WB 0.78
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (too) Vdefl Ud
-0.11 10-11 >999 360
-0.24 10-11 >999 240
0.06 7 n/a n/a
0.15 10-11 >999 240
PLATES GRIP
MT20 244/190
Weight: 194 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 3-3-10 cc purlins,
BOT CHORD 2x4 SP No.2
except end verticals, and 2-0-0 oc purlins (4-7-5 max.): 3-4.
WEBS 2x4 SP No.2 *Except* BOT CHORD
Rigid ceiling directly applied or 5-10-9 oc bracing.
1-12,6-7: 2x6 SP No.2 WEBS
1 Row at midpt 3-9
REACTIONS. (lb/size) 12=1241/0-7-10, 7=1241/0-7-10
Max Horz 12=211(LC 11)
Max Uplift 12=557(1_C 12), 7=557(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=2083/1160, 2-13=2013/1174, 2-14=-1707/1066, 3-14=1624/1080, 3-15=1502/1083,
15-16=1503/1082, 16-17=-1504/1082, 17-18=-1504/1082, 4-18=1505/1082,
4-19=162611081, 5-19=1708/1066, 5-20=-2009/1174, 6.20=2080/1161, 1-12=1171/765,
6-7=1171/766
BOT CHORD 11-12=162/370, 10-11=-988/1909, 10-21=-719/1500, 9-21=719/1500, 8-9=990/1859
WEBS 2-10=474/314, 3-10=84/401, 4-9=-112/368, 5-9= 477/315, 1-11=-885/1668,
6-8=886/1667
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=34ft; eaye=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS C-C Exterior(2) 0-2-12 to 3-7-9, Interior(1) 3-7-9to 14-7-14, Exterior(2) 14-7-14
•' �•9 ���
(directional) and
to 18-0-11, Interior(1) 18-0-11 to 19-7-14, Exterior(2) 19-7-14 to 23-0-11, Interior(1) 23-0-11 to 33-9-4 left
��� •r\`:•' G E N
Q : •\,\ SF�•.? ��
zone; cantilever and right
�41
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
i
No 58126
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
* _,• ;
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
-p ; ; CC
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
p :• F 41J Z
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 557 lb uplift at joint 12 and 557 lb uplift at
7.
((�
R
joint
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
,[•�
���` 0 f� •'� �j\ ���
n�
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Dater
January 3,2019
,&WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED NOTEK REFERENCE PAGE MI-7473 rev. 10/012015 BEFORE USE
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and pro pedy Incorporate this design into the overall'
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
WOW
fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSI/TPI1 quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
I T15924360
506926
Be
Hip
�Uty
1
1
Job Reference (optional)
ibbens Lumber Co, raim bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:51 2019 Page 1
ID:zNgPoPtcZMR2Gpw06QfmsEy71 ZM-GX2ZMTTglilf5AgpaLf2mf2XRflYoDDNb1 nlXrzzM7g
7-7-12 150-0 19.0.0 25-8.5 32-4.11 34-SO
7-7-12 7-4-4 4-0-0 6.8.5' 6.a-5 2-3-5
4x8 =
4xl
4x6 =
Scale = 1:61.1
NOP2X STP = 4x4 = 5x6 = 5x8 = 4x4 = 2x4 11 5x8 =
3x6 11
34-8-0
0 ,
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017lrP12014
CSI.
TC 0.78
BC 0.81
WB 0.89
Matrix -MS
DEFL. in
Vert(LL) -0.19
Vert(CT) -0.37
Horz(CT) 0.07
Wind(LL) 0.25
(loc) Vdefl Lid
9-10 >999 360
9-10 >999 240
8 n/a n/a
9-10 >999 240
PLATES GRIP
MT20 244/190
Weight: 201 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
6-7: 2x4 SP SS
end verticals, and 2-0-0 oc purlins (4-8-2 max.): 3-4.
BOT CHORD 2x4 SP No.2 'Except'
BOT CHORD
Rigid ceiling directly applied or 5-7-4 oc bracing.
8-11: 2x4 SP SS
WEBS
1 Row at midpt 2-12
WEBS 2x4 SP No.2 *Except*
1-14: 2x6 SP No.2, 7-8: 2x8 SP No.2
REACTIONS. (lb/size) 14=1263/0.7-10, 8=1263/0-10-1
Max Horz 14=219(1_13 10)
Max Uplift 14=-567(LC 12), 8=567(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=2130/1216, 2-15=-2058/1230, 2-16=-1720/1105, 3-16=1633/1126, 34=1511/1134,
4-17=1633/1135, 5-17=-1714/1115, 5-6=-2189/1300, 6-7=-1481/815, 1-14=1191/794,
7-8=743/426
BOT CHORD 13-14=160/388, 12-13=1083/1903, 11-12=-768/1507, 10-11=1097/1986, 9-10=756/1369,
8-9=720/1325
WEBS 2-12=535/359, 3-12=114/382, 4-11=-186/397, 5-11=-634/420, 6-10=-358/633,
6-9=469/388, 1-13=943/1695
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=35ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-2-12 to 3-8-6, Interior(1) 3-8-6 to 15-0-0, Exterior(2) 15-0-0 to
23-10-13, Interior(1) 23-10-13 to 34-4-6 zone; Cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 567 lb uplift at joint 14 and 5671b uplift at
joint 8.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED M ITEK REFERENCE PAGE MI.7473 rev. 10/07/2015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and SCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
%% �p 1J.1 O'R� .-
�.`Q�Z��'�G
No 58126
� r
�O: OF :�44/Z
i
• ,:off O R , O p. ,••\�,��
,O N A � E?C� �.
11111
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MF
MOW
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924361
506926
B7
Hip
1
1
Job Reference (optional)
Lurnuer Go, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:28:52 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-kjcxZpUSUOtViKPO82AHJtbld36TXiUXphWr3HzzM?f
2-3.13 8.7.14 15-0.0 23-0.0 29.4-2 358-3 38.0.0
2-3-13 83-1 6.4-1 8-0.0 6.4-1 6-4-1 2.3-13
5x8 =
5x6 =
Scale: 3/16"=l'
3x8 = 3x6 11 4x4 = 5x6 = 5x8 = 4x4 = NOP2X STP =
3x6 11 3x6 =
NOP2X STP =
38.0-0
tg.
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress ]nor YES
Code FBC2017/rPI2014
CSI.
TC 0.62
BC 0.63
WB 0.76
Matrix -MS
DEFL. in (loc) Vdefl Lid
Vert(LL) -0.14 11-12 >999 360
Vert(CT) -0.29 11-12 >999 240
HOrz(CT) 0.06 9 n/a n/a
Wind(LL) 0.13 12 >999 240
PLATES GRIP
MT20 244/190
Weight: 201 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-11-13 oc purlins,
4-5: 2x4 SP SS
except
BOT CHORD 2x4 SP No.2
2-0-0 oc!puriins (4-3-10 max.): 4-5.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0.7 oc bracing.
WEBS
1 Row at midpt 4-11
REACTIONS. (lb/size) 14=1406/0.7-10, 9=1406/0-7-10
Max Horz 14=-232(LC 10)
Max Uplift 14=-724(LC 12), 9=628(1_C 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-21=1956/1134, 3-21=-1891/1153, 3-22=-1746/1116, 4-22=1678/1134, 4-23=1550/1136,
23-24=1550/1136, 5-24=-1550/1136, 5-25=1677/1133, 6-25=1744/1115,
6-26=1891/1153, 7-26=-1956/1134
BOT CHORD 13-14=193/340, 12-13=-948/1867, 12-27=753/1613, 11-27=753/1613, 10-11=933/1746
WEBS 3-13=155/254, 3-12=293/225, 4-12=-27/384, 5-11=30/374, 6-11=-305/226,
6-10=155/254,2-13=1083/1707,2-14=-1281/1005,7-10=-1082/1708,7-9=1281/1004
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) nd: ASCE 1GCpi=O BExteao
J1111111/ 11.
'�' 0���
I�Exp C Encl., 18; MWFRS (directional) and C-1C Exterior(2) 0-0-0 of3 9- 01, Inte or(1) 3 9-10 to 15-0-0, (2)ft15-0-0
•' �9
to 20-4-8, Interior(1) 20-4-8 to 23-0-0, Exterior(2) 23-0-0 to 28-4-8, Interior(1) 28-4-8 to 38-0-0 zone; cantilever left and right exposed
for forces & MWFRS for Lumber DOL=1.60 DOL=1.60
��%,•r\\ :•' G E N j
Q : •\ SF••.� %/ �0
;C-C members and reactions shown; plate grip
��
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for 10.0 bottom chord live load with any other live loads.
No 59126
a psf nonconcurrent
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
-D ;
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 724 lb uplift at joint 14 and 628 lb uplift at
joint 9.
�j : F 411
••
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
i�,T • . Q P : ��,��
0
111
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Gert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE IMI.7473 rev. 1010312015 BEFORE USE
'
Design valid for use only with MTekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall'
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Well(
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP1I Quality Made, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge courtyard
T15924362
506926
B8
Hip
1
1
Job Reference (optional)
Lumber Go, raim Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:28:54 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-g6ji_WiOd7DydYOFTCIOlg6VspH?fEgH??y8AzzM?d
2.3-13 7-7-14 13-0.0 19.0-0 25-0.0 30-4-2 31-2- 35.8-3 38-0-0
2-3-13 5-0-1 6-0.0 6.0.0 5.4.1 0-10- 4-6.1 2-3-13
Scale: 3/16"=l'
5x8 = 2x4 II 5x8
I$.
3x8 = 3x6 11 4x4 = 5x6 = 3x8 = 5xe = 4x4 = NOM STP =
3x6 11 3x8 =
NOP2X STP =
2-0-0 2- -13 7-7-14 13-0-0 19-0-0 25A-0 30-0-2 35-e-3 36 A 38-0-0
2-0-0 0.0. - 3 54-1 5415a-1
Plate Offsets (X,Y)—
[1:0-0-14,0-0-2],[4:0-5-12,0-2-8],[6:0-5-12,0-2-8],[12:0-3-0,0-3-0],[14:0-3-0,0-3-0]
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL) -0.12 13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.48
Vert(CT) -0.22 12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.56
Horz(CT) 0.06 10 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.16 13 >999 240
Weight: 206 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 BOT CHORD
REACTIONS. (lb/size) 16=1406/0-7-10, 10=1406/0-7-10
Max Horz 16=-201(LC 10)
Max Uplift 16=-724(LC 12), 10=628(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-23=1898/1118, 3-23=-1842/1134, 3-4=-1826/1177, 4-24=1894/1299, 24-25=1894/1299,
5-25=1894/1299, 5-26=-1894/1299, 26-27=-1894/1299, 6-27=1894/1299,
6-7=1826/1177, 7-28=1842/1134, 8-28=-1898/1118
BOT CHORD 15-16=176/269, 14-15=-943/1721, 13-14=-821/1630, 12-13=807/1630, 11-12=-928/1700
WEBS 3-15=-228/285, 4-14=13/257, 4-13=-264/463, 5-13=-369/383, 6-13=264/463,
6-12=13/257, 7-11=228/285, 2-1 5=-1 110/1728, 2-16=-1287/980, 8-11=-1110/1728,
8-10=1287/980
Structural wood sheathing directly applied or 4-0-10 oc pudins, except
2-0-0 oc'purlins (3-10-10 max.): 4-6.
Rigid ceding directly applied or 6-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vesd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=38ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-9-10, Interior(1) 3-9-10 to 13-0-0, Exteri6r(2) 13-0-0
to 18-4-8, Interior(1) 18-4-8 to 25-0-0, Exterior(2) 25-0-0 to 30-4-2, Interior(1) 30-4-2 to 38-0-0 zone; cantilever left and right exposed
;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 724 lb uplift at joint 16 and 628 lb uplift at
joint 10.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord
A& WARNING - Ve ft design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERENCE PAGE 11,111-7473 rev. 101031201E BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall,.
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-e9 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
11111111//��
J. O'qF
No 58126
a
� � S OE : ��
0 w:
s,ON A� 0%���,
nl
Philip J. O'Regan PE No.58126
M[Tek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
M1
MOW
6904 Parke East Blvd.
Tampa,FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924363
506926
Be
Hip
1
1
Job Reference (optional)
iooens Lumber Coo, Palm Bay. FL Run: 8.240 s Dec 62018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:28:55 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-81H4BgWKnxF4an7bpBk xVDH3G5Yk49zVfKtgczzM?c
2-3-13 5-98-1.14 11-0.0 19.0.0 27.00-0 32-2-2 35.8.3 38-0-0
' 2-3-13 3.' 5-2-2 8-0-0 6--0 S-2-2 3-8-1 2-3-13
5x8 =
2x4 11
5x8 =
3x6 = 6x6 Sx6 = 3x8 = 5x6 =
NOP2X STP =
Scale: 3/16'=1'
NOP2X STP =
6x6 = 3x6 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.26
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TIC 0.55
BC 0.74
WB 0.64
Matrix -MS
DEFL, in (loc) I/deft L/d
Vert(LL) -0.13 12 >999 360
Vert(CT) -0.26 11-12 >999 240
Horz(CT) 0.09 10 n/a n/a
Wind(LL) 0.17 12 >999 240
PLATES GRIP
MT20 244/190
Weight: 193 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-114 oc purlins, except
4-6: 2x4 SP SS
2-0-0 oclpurlins (3-11-3 max.): 4-6.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 cc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 14=1406/0-7-10, 10=1406/0-7-10
!
Max Horz 14=170(LC 11)
Max Uplift 14=-724(LC 12), 10=628(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=321/45, 3-4=1915/1177, 4-22=-2279/1494, 22-23=-2279/1494, 5-23=2279/1494,
5-24=2279/1494, 24-25=-2279/1494, 6-25=-2279/1494, 6-7=1915/1178, 8-9=321/45
BOT CHORD 1-14=17/310, 13-14=886/1514, 12-13=-872/1719, 11-12=-858/1719, 10-11=872/1488,
9-10=17/310
WEBS 3-13=-76/362, 4-12=447/739, 5-12=-499/506, 6-12=-447/739, 7-11=76/362,
3-14=1842/1401, 2-14=-158/290, 7-10=-1842/1401, 8-10=-158/290
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=38ft; eave=5ft; Cat.
`,�1111111/1�
%%`, 0,
and C-C
to 16-4-8, ntelrion((1C)16-4-8 to 27 0-0 (directional)
dExte to (2))27 0 0 t 32-3-1 rinterior(1) 32-3-1 Otol38-0-0 zone; cantilever left and eright2 exposed
%,•r��\p .........
E /� 9��q'��j
;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
No 58126
4) All plates are MT20 plates unless otherwise indicated.
has been designed for 10.0 bottom live load live loads.
5) This truss a psf chord nonconcurrent with any other
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
'0
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 724 lb uplift atjoint 14 and 628 lb uplift at
:� F (V -
0
joint 10.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord:
00 0
Philip J. URegan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED WTER REFERENCE PAGE MI-7473 rev, 101=015 BEFORE USE
Design valid for use only with MiTek® connectors.. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Beforeuse, the building designer must verify the applicability of design parametersand properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
MiTek`
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TF1l Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924364
506926
810
Hip Girder
1
1
Job Reference (optional)
Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:00 2019 Page 1
I D:zNgPoPtcZM R2GpwOb QfmsEy71 ZM-VG4zEYaTcTtNhYOYbkJAeZw5VHgyP Mv'IfxSGLgzzM?X
9-0-0 15-8-9 22-3-7 29-0-0 38-0-0
9.0.0 6-8.9 6-6-13 6.8.9 9.0-0
6x6 =
5.00 12
2x4 11 7x8 =
5x8 =
3x6 II cu tr za zo zi zo zu au J1
3x6 = 4x6 = 5x8 = 2x4 11 7x8 NOP2X STP =
NOP2X STP =
Scale: 3/16"=l'
3x6 11 3x6 =
2-0-0 2-3-13 9-0-022-0-7 29-0-0 358.' 38,Or0 36-0-0
2-0-0 0.3-13 6-8-3 6-8-9 6-6-13 6-8-9
Plate Offsets (X,Y)—
[1:0-0-14,0-0-2] [3:0-3-0,0-2-9], [5:0-4-0,0-4-8], [10`.0-2-12,Edge]
[12:0-4-0 0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES. GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL) -0.20 11-12 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.59
Vert(CT) -0.43 11-12 >933 240
BCLL 0.0
Rep Stress Incr NO
WB 0.61
Horz(CT) 0.09 9 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Wind(LL) 0.25 11-12 1 >999 240
Weight: 206 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP N0.2 *Except*
3-5,5-6: 2x6 SP No.2
BOT CHORD
2x4 SP SS *Except'
8-10: 2x4 SP No.2
WEBS
2x4 SP No.2
REACTIONS.
(lb/size) 14=1816/0.7-10, 9=1814/0-7-10
Max Horz 14=-139(LC 6)
Max Uplift 14=-813(LC 8), 9=716(LC 8)
Max Grav 14=1822(LC 29). 9=1819(LC 30)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins, except
2-0-0 oclpurlins (3-6-13 Max.): 3-6.
BOT CHORD Rigid ceiling directly applied or 6-4-6 oc bracing.
WEBS 1 Row at midpt 5-10
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2855/1016, 3-21=3734/1303, 4-21=-3736/1302, 4-5=-3734/1301, 5-22=2603/1017,
6-22=2602/1018, 6-7=2862/1040
BOT CHORD 13-14=-133/311, 13-23=-799/2642, 23-24=-799/2642, 24-25=799/2642, 12-25=799/2642,
12-26=1111/3745, 26-27=-1111/3745, 27-28=-1111/3745, 11-28=1111/3745,
11-29=1111/3745, 29-30=-1111/3745, 30-31=-1111/3745, 10-31=1111/3745
WEBS 2-13=810/2439, 3-13=1291405, 3-12=-349/1477, 4-12=-424/322, 5-11=0/503,
5-1 0=1 455/335, 6-10=77/808, 7-10=-749/2453, 2-14=-17641857, 7-9=1755/807
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=38ft; eaye=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 813 lb uplift at joint 14 and 716 lb uplift at
joint 9.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.,
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 72 lb down and 146 Ib up at
9-0-0, and 72 lb down and 146 lb up at 29-0-0 on top chord, and 331 lb down and 144 lb up at 9-0-0, 69 lb down at 11-0-12. 69 lb
down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 19-0-0, 69 lb down at 20-11-4, 69 lb down at
22-11-4, 69 lb down at 24-11-4, and 69 lb down at 26-11-4, and 331 lb down and 144 lb up at 28-11-4 on bottom chordi The
design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
,& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED mrrEK REFERENCE PAGE mi-7477 rev. 101=015 BEFORE -USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parametersand property Incorporate this design into the overall,
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TP/1 QuaW Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
�II111111/1I
0 �Q J. O'fj
i.0
No 58126
• '0 : : it
OF
OR
10
S/O N A1. E��`>`�
1811111111s
Philip J. O'Regarf PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTek°
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
i
T15924364
506926
B10
Hip Girder
1
1'
Job Reference (optional)
ID:zNgPoPtcZMR2GpwObQfr isEy71ZM-VG4zEYaTcTtNhYOYbkJAeZw5VHgyPMvifxSGLgzzM7X
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=54, 3-6=54, 6-8=-54, 15-18=-20
Concentrated Loads (lb)
Vert: 3=-44(F) 6=-44(F) 13=-172(F) 10=172(F) 23=-43(F) 24=-43(F) 25=-43(F) 26=43(F) 27=-43(F) 28=43(F) 29=43(F) 30= 43(F) 31=43(F)
A WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED M TEK REFERENCE PAGEMI-7473 rev. 101=016 BEFORE�USE
Design valid for use only with MTekG connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
e truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rP11 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
�Cil
T15924365
506926
]CtY
Corner Jack
12
1
'
Job Reference (optional)
ar Co. Palm Bay. FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:02 2019 Page 1
ID:zNgPoPtcZMR2GpwOb,QfmsEy7lZM-ReCjfEbj8485wsAxj9Mej2Y15axtOo?6FxNQi7zM?V
3-0-0
3-0-0
Scale = 1:10.7
5
NOP2X STP =
2-7-10 3x6 II g�0
2-7-10 D-0�
Plate Offsets (X,Y)—
[1:0-1-14,0-0-101
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) i I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.31
Vert(LL)
0.00
5 1 >999
360
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.37
Vert(CT)
0.00
5 >999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.07
Horz(CT)
0.03
3 n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
-0.00
5 >999
240
Weight: 11 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x6 SP No.2
REACTIONS. (lb/size) 3=-139/Mechanical, 4=-159/Mechanical, 5=515/0-7-10
Max Horz 5=66(LC 12)
Max Uplift 3=-139(LC1), 4=-159(LC 1), 5=420(LC 12)
Max Grav 3=103(LC 12), 4=130(LC 12), 5=515(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-5=267/562
BRACING -
TOP CHORD Structuralwood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=151t; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 139 lb uplift at joint 3, 159 lb uplift at joint
4 and 420 lb uplift at joint 5.
,&WARNING • Verify design parameter; and READ NOTES ON THIS AND INCLUDED MIIEK REFERENCE PAGE M11.7473 rev. 1010=015 BEFORE USE
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual tmss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. !
��unurrr,
J. O'qF
�. tC• •, �i
No 58126 10
oo Al
Philip J. O'Regan PE No.56126
MIT& USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTek'
6904 Parke East Blvd.
Tampa,FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
508926
CJ1P
Corner Jack
4
1
T15924366
i
Job Reference (optional)
palm Say, rL stun: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 Mrrek Industries, Inc. Wed Jan 2 16:29:02 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-ReCjfEbj8485wsAxj9Mej ?YO5aLtOu?6FxNQizzM?V
3-0-0
3-0-0
Scale = 1:10.7
2-6-0
2-6.0
0�-0
LOADING (psf)
SPACING-
2-0-0
CSI,
DEFL.
in
(loc) Vdefl
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.29
Vert(LL)
0.00
5 >999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.34
Vert(CT)
0.00
5 >999
240
BCLL 0.0
Rep Stress Incr
YES
WE 0.06
Horz(CT)
0.03
3 n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Wind(LL)
-0.00
4-5 >999
240
Weight: 11 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x6 SP No.2
REACTIONS. (lb/size) 3=-114/Mechanical, 4=133/Mechanical, 5=464/0-6-0
Max Horz 5=66(LC 12)
Max Uplift 3=-114(LC 1), 4=-133(LC 1), 5=389(LC 12)
Max Gram 3=81(LC 12), 4=97(LC 12), 5=464(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-5=243/508
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extericr(2) zone; cantilever left and right exposed ; porch left exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 114 lb uplift at joint 3, 133 Ibluplift at joint
4 and 389 lb uplift at joint 5.
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MiTEK REFERENCE PAGE M I-7473 rev. 10/03/2015 BEFORE USE
Design valid for use only with MrrekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
�IIIIIIIIIII�
NV \G ENS' ��Z 0i
N0 58126
nl
Phillp J. O'ReganPE No.58126
III USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTeW
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924367
506926
CJ3
Comer Jack
12
1
Job Reference (optional)
iooers Lumeef Co, Palm tray, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industdes, Inc. Wed Jan 2 16:29:03 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-vrrn5tacLvOGyYOk7HsttFBYlyVyocrZBLvhwy9zzM?U
5-0-0
5-0-0
Scale = 1:16.4
NOP2X STP =
2x4 11
i
2-0-0 2-3-13, 4-M 5-0-0
2-0-0 3-13 1.8-3
Plate Offsets X,Y —
1:0-1-14,0-0-10
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) ; Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.17
Vert(LL) 0.00 5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.20
Vert(CT) 0.00 5 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT) 0.01 3 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MP
Wind(LL) -0.01 5 >999 240
Weight: 19 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied
or 6-0-0 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=51/Mechanical, 4=30/Mechanical, 6=344/0-7-10
Max Horz 6=11O(LC 12)
Max Uplift 3=-52(LC 12), 4=-30(LC 1), 6=239(LC 12)
Max Grav 3=57(LC 17), 4=37(LC 12), 6=344(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=415/179
BOT CHORD 1-6=135/414
WEBS 2-6=312/578, 2-5=269/157
NOTES-
1) Wind: ASCE 7-10: Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 070-0 to 3-0-0, Interior(1) 3-0-0 to 4-114 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.6011
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This has been designed for live load 20.Opsf the bottom in 3-6-0 tall by 2-0-0
♦♦����{
truss a of on chord all areas where a rectangle wide
♦�♦ \\; ...... I
will fit between the bottom chord and any other members.
5) Refer for truss to truss
,♦♦QXN •* G E IV S '.
V F �'.�
to girder(s) connections.
♦ i
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 3, 30 lb uplift at joint 4
v
NO 58126
and 239 lb uplift at joint 6.
'O
Fdo
%%%♦♦
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
A WARNING - Ve ft design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERENCE PAGE M11-7473 rev. 10/03/Y015 BEFORE USE
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
��
at russsystem. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall;
building design. Bracing indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTeiC'
prevent
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlt Quality Criteria, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314.
Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
Gopher Ridge Courtyard
I
T15924369
506926
CJ5
Corner Jack
12
1'
Job Reference (optional)
wucu• wumo� raw oey , r� Run: mzqu s uec o zuiu Ynm: o.L4u s uec lu Zulu mi I eK mausmes, Inc. vvea Jan Z lu:Z9:u4 Zul9 rage 1
ID:zNgPoPtcZMR2GpwObQfmsEy7lZM-N1 KU4vd_fiOo9AJJgaO6oP5tjuJdLlslaZ000bzzM?T
7-0-0
7-0-0
Scale=1:20.8
6 4
NOP2X STP =
2x4 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.36
Vert(LL)
-0.03
4-5 >999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.16
Vert(CT)
-0.03
4-5 >999
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.10
Horz(CT)
0.02
3 n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 26 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Struc
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=1 01 /Mechanical, 4=27/Mechanical, 6=385/0-7-10
Max Horz 6=155(LC 12)
Max Uplift 3=-101(LC 12), 6=235(LC 12)
Max Grav 3=109(LC 17), 4=64(LC 3), 6=385(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=340/135
BOT CHORD 1-6=102/318
WEBS 2-6=354/559
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft;
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-11-4 zone;
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall I
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 3 and
joint 6.
41 wood sheathing directly applied or 6-0-0 oc purlins.
iling directly applied or 6-0.0 oc bracing.
Cat.
left
2-0-0 wide
lb uplift at
�IIIIIIIIII�
�� 1`�\: ' •(•� ESN g :''q ����
`%��
0
No 58126
411 •
Philip J. O'Regan PE No.58126
MITek USA, Inc. FLBert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473rev. 10103/201S BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall!
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPi1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924369
606926
D1
Roof Special
1
1
Job Reference (optional)
ioo-5 Lumoer co, ralm Day, VL Itun: 6.240 a Uec 6 zuia Print 6.240 s Uec 16 2015 MITeK Industnes, Inc. wed Jan 2 16:29:06 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-sDuslFecQ?WfnJuWOHvLLcdzllNff4fCRpDA101 zzM?S
7-4-12 14.6-0 16-7-14 21-7-14 26-10-6 2&11-2
7-4-12 7-1-4 2-1-14 5 0-0 5-2-8 2-0-12
Scale = 1:53.0
5x6 =
3x4
6x6 =
3x4 =
4x4 = 4:A
5x8 = 3x4 =
3x8 =
2x4 11
8 5-11 16-7-14 21-7-14 26-10.6 28 11-2
r A-5-11 A-2 3 5-0-0 2-0-12
Plate Offsets (X,Y)—
15:0-540-2-0] [7:0-3-4,0-3-0] [11:0-4-0,0-3-0] 1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL) -0.19 11-12 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.75
Vert(CT) -0.33 11-12 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.48
Horz(CT) 0.07 15 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Wind(LL) 0.11 11-12 >999 240
Weight: 190 lb FT = 20%
LUMBER- BRACING- I
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing
directly applied or 3-7-5 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals, and 2-0-0 oc purlins (4-10-1 max.): 4-5, 6-7.
WEBS 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied
or 5-11-10 oc bracing.
1-13: 2x6 SP No.2 WEBS 1 Row at midpt
2-13
OTHERS 2x8 SP No.2
I
REACTIONS. (lb/size) 13=1051/Mechanical, 15=1017/0-6-12
Max Horz 13=157(LC 11)
Max Uplift 13=-459(LC 12), 15=470(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=298/253, 2-16=241/267, 2-17=-1663/1036, 3-17=-1592/1046, 34=1349/936,
4-18=1221/824, 18-19=-1221/824, 5-19=-12211824, 5-20=-1025/669, 6-20=1077/660,
8-14=659/1065, 7-14=659/1065, 1-13=-266/299
BOT CHORD 12-13=947/1598, 12-21=-643/1113, 21-22=-643/1113, 11-22=643/1113, 10-11=537/941,
9-10=281/474, 8-9=277/474
WEBS 2-12=268/363, 3-12=317/628, 3-11=-284/561, 4-11=-659/522, 5-11=261/555,
5-10=273/247, 6-1O=338/582, 6-8=-1058/618, 2-13=-1477/753, 7-15=1044/615
/1111111/II/
NOTES-
1) Unbalanced live loads have been for this design.
roof considered
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; eave=4ft; Cat.
��� ��` :•' G E N �q
Q '�� `SF•'.? �i
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1) 3-2-12 to 14-6-0, Exterior(2) 14-6-0
��
to 16-7-14, Interior(1) 16-7-14 to 21-7-14, Exterior(2) 21-7-14 to 24-7-14, Interior(1) 24-7-14 to 28-2-2 zone; cantilever left and right
No 58126
•:
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
* .
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
1 to formula. Building designer
1
7) Bearing atjoint(s) 15 considers parallel to grain value using ANSUTPI angle grain should!verify�
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 459 lb uplift at joint 13 and 470 to uplift at
��`S1'•..•••••,.• `�
joint 15.
,,,���/ N P►' 1�`,,,
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord:
Phillp J. O'Regan PE No.58126
MlTek USA, Inc. FL Bert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 59TEK REFERENCE PAGE M I-7473 rev. 10/02,2015 BEFORE USE. OF
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overalls
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek°
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS1/TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
'
Gopher Ridge Courtyard
T75924370
506926
D2
Roof Special
�Qty
1
1
Job Reference (optional)
ibbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Pdnt: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:07 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-ocOcixfsydmNOd2uWixpQljKU6F?YXkkGXf85wzzM?Q
24.11.6
24-10-6
i 6-5-12 12-8-0 14-&0 18-7-14 23-7-14 24-9-0 i 26.4-0 28-11-2
6-5.12 8-2-4 1-10.0 4-1.14 5.0.0 1-1-8 1-4-10 2-7-2 Scale = 1:53.7
0-1-0
5x6 = 0-1-0
9vA II
46
3x4 = 3x8 =
18 17 16
3x6 II 48 = 2x4 II
11 10
2x4 II 4x4 =
20 4
19 4 I a 14
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL) -0.09 14-15 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.50
Vert(CT) -0.21 14-15 >999 240
BCLL 0.0
Rep Stress Incr YES
WE 0.60
Horz(CT) 0.08 20 file n/a
BCDL 10.0
Code FBC2017lfP12014
Matrix -MS
Wind(LL) 0.13 14-15 >999 240
Weight: 209 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals, and 2-0-0 oc purlins (5-2-5 max.): 5-6, 7-9.
WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-11-2 oc bracing.
OTHERS 2x8 SP No.2
REACTIONS. (lb/size) 18=1054/Mechanical, 20=1020/0-6-12
Max Horz 18=201(LC 12)
Max Uplift 18=-453(LC 12), 20=-478(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-21=1713/901, 2-21 =1 651/913, 2-22=-1659/975, 3-22=-1547/993, 3-4=-1622/1091,
4-23=1815/1178, 5-23=-1859/1169, 5-24=-1073/674, 6-24=1073/674, 6-7=1142/690,
7-8=579/346, 8-9=571/341, 1-18=-991/624
BOT CHORD 17-18=330/266, 3-15=248/288, 14-15=-769/1268, 13-14=-990/1662, 12-13=560/929
WEBS 2-17=314/340, 15-17=936/1476, 4-15=-425/681, 4-14=-425/696, 5-14=438/417,
5-13=777/454, 6-13=43/251, 7-13=-246/397, 7-12=-873/535, 9-12=659/1101,
1-17=643/1372, 9-20=1034/616
NOTES-
,,�11111181,1
1) Unbalanced roof live loads have been considered for this design.
Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; Cat.
,��� J Q, 1IJ*
\Q A� �j
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) eave=4ft;
%
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-6-0, Exterior(2) 14-6-0
an
24-10-6, Interior(1) 24-10-6 to 28-2-2 left d
`%� .r�\ :r' G E J�
Q '•�,\
to 17-6-0, Interior(1) 17-6-0 to 23-7-14, Exterior(2) 23-7-14 to zone; cantilever right
��
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
No 58126 o
•:
3) Provide adequate drainage to prevent water ponding.
live loads.
* .• * "
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
formula. Building designer
�O F 441/�
7) Bearing atjoint(s) 20 considers parallel to grain value using ANSI/TPI 1 angle to grain shouldl verify
�j T• Q;••
capacity of bearing surface.
18 478 lb
��
••'
R •' ��
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 453 lb uplift at joint and
uplift atjoint
•.
20.
�ss'O N AL
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord;
It%
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERENCE PAGE Ml1.7473 rev. 1010312015 BEFORE USE.
°
Design valid for. use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly, incorporate this design Into the overalll
Indicated is to buckling Individual truss web and/or chord members only. Add ltional temporary and permanent bracing
MiTek`
building design. Bracing prevent of
Isalways required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPN Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher
Gopher Ridge Courtyard
T15924371
606926
D3
Roof Special
1
1
Job (optional)
iuuaaa a.umaer C., raim Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:08 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy,71ZM-GoZ wHgUjwuEend43PT2yFFWrWYYHwQtVBOhdMzzM?P
6 5 12 12-8-0 V3 _Q 20-8-6 264-0 28-11-2
' 6-5-12 ' 6-2-4 -10 7-2-6 ?1 7-10 2-7-2
2x4 11
3x4 = 3x4 = 5x6 =
5.00 112
Scale = 1:53.9
4x12 = =
15 23 14 13 3x10 9 8
3x6 II 4x8 = 2x4 II 2x4 II 4x4 =
26-4-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress ]nor YES
Code FBC2017/TPI2014
CSI.
TC 0.48
BC 0.68
WB 0.83
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) -0.16 11-12 >999 360
Vert(CT) -0.36 11-12 >948 240
Horz(CT) 0.07 17 n/a n/a
Wind(LL) 0.13 11-12 >999 240
PLATES GRIP
MT20 244/190
Weight: 216 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins,
4-5: 2x4 SP SS except end verticals, and 2-0-0 oc purlins (4-0-6 max.): 1-4, 5-7.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0.0 oc bracing.
WEBS 2x4 SP No.2 WEBS 1 Row at midpt 1-15, 1-14
OTHERS 2x8 SP No.2
REACTIONS. (lb/size) 15=1054/Mechanical, 17=102010-6-12
Max Horz 15=-161(LC 12)
Max Uplift 15=-506(LC 12), 17=-425(LC 12)
Max Grav 15=1092(LC 18), 17=1020(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-15=1000/699, 1-18=-737/461, 2-18=-737/461, 2-19=-1209/738, 19-20=-1209/738,
3-20=1209/738, 3-21=1215/736, 4-21=-1215/736, 4-22=-2050/1151, 5-22=2121/1140,
5-6=1842/931, 6-7=667/359
BOT CHORD 12-24=579/1202, 24-25=-579/1202, 11-25=-579/1202, 10-11=376/694, 6-10=981/604
WEBS 1-14=700/1122, 2-14=837/665, 12-14=-256/763, 2-12=-390/674, 4-12=-106/252,
5-11 =1 127/770, 6-11=646/1369, 7-10=-652/1200, 4-11=-509/910, 7-17=10371544
,��111111/II/
NOTES-
1) ASCE 1GCpi I0
��� �11
J O R��,,'♦♦
nd:
13-6-0,
•
I�Exp C; Encl., 18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, ntterior(1)13-1-12 to Exterior(2) 13-6-0
%�,
'�` G E N3'• 'y ♦i
�'�
to 16-6-0, Interior(1) 16-6-0 to 28-2-2 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
�'1 Q : F�'.?oo
shown; Lumber DOL=1.60 plate grip DOL=1.60
No 56126. •
2) Provide adequate drainage to prevent water ponding.
S
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
;
5) Refer to girder(s) for truss to truss connections.
:� OF .7141J
6) Bearing atjoint(s) 17 Considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer shouldlverify
00.
Capacity of bearing surface.
♦♦ T,c� Q' .' w�
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 506 lb uplift atjoint 15 and 425 lb uplift atjoint
♦♦��•s '•. fi �G•'•`G\ `��
17.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord;
Philip J. O'Regan PE No.58126
MiTek USA, Inc. R. Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING-Veriffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 101031201E BEFORE USE.��
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ,
a truss system. Befo re use, the building designer must verify the applicability of design parameters andproperly incorporate this design Into the overall,
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/1TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924372
506926
04
Roof Special Girder
1
1
Job Reference (optional)
lbbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:09 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-k-7N7dh6UE05GxCHd7—HVSobtvuZONiljr8F9ozzM?O
6-512 12-M 19-1-3 2248-6 26-0 0 28-11-2
6-5-12 6-2-4 2-10-0 3-7-3 3-7-3 - 3-7-10 2-7-2
Scale = 1:51.1
44 =
3x4 =
2x4 11 4x8 =
19
d,
A
0
N19
24 3x4 = 3x4 =
17 16 15 10 9
3x6 II 4x8 = 2x4 II 2x4 II 4x4 =
6-512 12-M 11112 19-1-3
22-8-6 26-4-0 28-11-2
6 512 6-2� 2-10-0 3.7-3
3-7 3 3 7-10 2-7-2
Plate Offsets (X,1)—[4:0-5-4,0-2-01,18:0-3-12,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in ([cc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.85
Vert(LL) -0.11 12-13 j >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.69
Vert(CT) -0.26 12-13 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.83
Horz(CT)
0.08 19 n/a n/a
BCDL 10.0
Code FBC2017ffP12014
Matrix -MS
Wind(LL)
0.14 12-13 >999 240
Weight: 209 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 3-8-4 cc purlins, except
BOT CHORD 2x4 SP No.2
end verticals, and 2-0-0 cc puffins (4-7-10 max.): 1-4, 6-8.
WEBS 2x4 SP No.2 BOT CHORD
Rigid ceiling directly applied or 6-0-0 cc bracing.
OTHERS 2x8 SP No.2
REACTIONS. (lb/size) 17=1074/Mechanical, 19=1232/0-6-12
Max Horz 17=-161(LC 8)
Max Uplift 17=-515(LC 8), 19=549(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-17=1020/543, 1-2=850/411, 2-20=-1395/680, 3-20=-1395/680, 3-21=1396/678,
21-22=13961678, 4-22=-1396/678, 4-5=-1583f710, 5-6=-2423/1060, 6-23=1063/489,
7-23=1063/489, 7-8=1035/471
BOT CHORD 13-14=529/1434, 12-13=-758/1772, 11-12=-923/2191, 7-11=476/306
WEBS 1-16=585/1210, 2-16=862/555, 14-16=-261/778, 2-14=-352/719, 4-13=176/527,
5-13=514/342, 5-12=265/642, 6-12=-349/280, 6-11 =-1 3521521, 8-11=711/1552,
8-19=1276/568
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS left Lumber DOL=1.60 DOL=1.60
%%J111111111j
`%%% J 0, 1I��
(directional); cantilever and right exposed ; plate grip
2) Provide adequate drainage to water
�%
• G,9 ,�ji
�\� •� E /�
prevent ponding.
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Ci •
�Q tS'
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
No 58126 0
•:
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) for truss to truss
=
* .
Refer to girder(s) connections.
6) Bearing at joint(s) 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
VO
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 515 lb uplift at joint 17 and 549 lb uplift at
S (V
joint 19.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
0
is T,e• ,
�s�`,`
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 54 lb down and 106 lb up at
•••`GN
• • • •
24-7-4, and 197 lb down and 89 lb up at 26-6-14 on top chord. The design/selection of such connection device(s) is thel.....
�` ���
��11�0 N A1j11�1,%
responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Philip J. URegan PE No.58126
LOAD CASE(S) Standard
MITek USA, Inc. FL Cert 6634
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
69M Parke East Blvd. Tampa FL 33610
Uniform Loads (plf)
Date:
Vert: 1-4=-54, 4-6=-54, 6-8=-54, 15-17=-20, 11-14=-20, 9-10=-20
January 3,2019
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE IWI.7473 rev. 10/02/2015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not ,
a truss system. Before use, the building designer must verify the applicability of design parametersand properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporaryend permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T75924372
506926
04
Roof Special Girder
1
1
�
Job Reference (optional)
muuus Lumoar co, raim nay. M
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 7=-194(B) 23=-39(B)
Run: 8.240 s Dec 5 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:09 2019 Page 2
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-k_7N7dh6UE05GxCHd7_HVSobtvuZONiljr8F9ozzM70
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGENI-7473 rev. 101=015 BEFORE USE
Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPN Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924373
506926
05
Roof Special
1
1
Job Reference (optional)
ibbens Lumber uo, vaim nay, FL Run: 8.240 a Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:10 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-CBhlLzilFY8yt5nTBgV W2gLrIJCIIoDAyUtoiFzzM7N
6-5 12 12-8-0 15 8-0 6.7- 215-8 26-4-0 28$ 3 31-0-0
6-5-12 6-2.4 3-0-0 - -11- 4-10-8 4-10-8 21 2-3-13
Scale = 1:54.1
5.00 12
4x6 =
4x4 = 3x4 = 2x4 II 5x8 =
]-I9
3x6 II 48 = 2x4 II I 4x4=NOP2XSTP = 3x4 =
2x4
6-5 12 12-8-0 15 8-0
16 7 q
21-5 6 261-0 28 83 29 O 031-0-0
6-5 12 6-2-4
3-0-0
11
4-10 8 410-8 2� 3 0- 3 2� 0
Plate Offsets (X,Y)— [4:0.5-4,0-3-0], [8:0-4-0,0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL)
-0.16 15-16 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.82
Vert(CT)
-0.30 15-16 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.94
Horz(CT)
0.13 10 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Wind(LL)
0.20 15-16 >999 240
Weight: 200 lb FT = 20%
LUMBER-
TOP CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-9-0 oc purlins, except
BOT CHORD 2x4 SP No.2
end verticals, and 2-0-0 oc purlins (4-0-13 max.): 1-4.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 19=1049/Meclianiral, 10=1234/0.7-10
Max Horz 19=-302(LC 12)
Max Uplift 19=-501(LC 12), 10=524(1-13 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-19=994/680, 1-23=944/572, 23-24=-944/572, 2-24=-944/572, 2-3=1589/927,
3-25=16021930. 4-25=1602/930, 4-5=-1502/897, 5-26=-15861922, 6-26=1677/912,
6-7=2082/1039, 7-27=2075/893, 8-27=-2115/886, 8-9=-267/153
BOT CHORD 18-1 9=1 42/332, 3-16=332/293, 15-16=-548/1492, 14-15=-555/1506, 13-14=793/1877,
12-13=866/2204, 10-11 =-281/381, 9-1 0=-1 14/272
WEBS 1-18=760/1256, 2-18=856/643, 16-18=-248/912, 2-16=-433/794, 4-16=-128/318,
4-15=444/264, 5-14=311/717, 6-14=-491/279, 7-13=-402/215, 8-1 0=1 1841748,
8-11=-469/520, 8-12=666/1715
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE.7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; save=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-2-15, Interior(1) 3-2-15 to 16-7-0, Exterior(2) 16-7-0
to 19-8-3, Interior(1) 19-8-3 to 31-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for'reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to.girder(s) for truss to truss Connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 501 lb uplift at joint 19 and 524 lb uplift at
joint 10.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
® WARNING - Verffy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE It9/-7473 n:v. 1010&2015 BEFOREI USE
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the I
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/7 Quality Criteda, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314.
'till 111111/oo,
`00
% V F �.0 No 58126.11
•
�%�`,,
��/1111111
Philip J. O'Regan PE No.58126
MRek USA, Inc. FL Gert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
Nil
MITek°
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
P
T15924374
506926
IDS
Roof Special
1
1
Job Reference (optional)
ibbens Lumber Go, vaim Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:12 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfms.Ey71 ZM-8ZpVmej7n9Og7OwslFXJ5QBF7xQDjjTQoMvm7zZM7L
L _ 641,12 12-8-0 13 8 0 16-7-0 2105-8 26.4-0 28$3 31-0-0
65-12 6-2.4 -0A 2-11-0 4-10-8 4-10.8 2-0-3 2-3-13
Scale = 1:54.1
5.00 12 4x4 =
2x4 II
18 17 16 'x'' — 11 10
3x6 11 48 = 2x4 11 4x4 =NOP2X STP = 3x4 =
3x4 = 2x4 II
20-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL) -0.13
14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(CT) -0.25
13-14 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.87
Horz(CT) 0.13
10 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Wind(LL) 0.17
3 >999 240
Weight: 195 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-6-11 oc purlins,
BOT CHORD 2x4 SP No.2
except end verticals, and 2-0-0 oc purlins (3-11-7 max.): 1-4.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 18=1049/Mechanical, 10=1234/0-7-10
Max Horz 18=-258(LC 12)
Max Uplift 18=-493(LC 12). 10=532(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-18=993/666, 1-22=11051651, 22-23=-1105/651. 2-23=11051651, 2-3=1899/1080,
3-4=1903/1078, 4-5=2152/1218, 5-24=-1887/1066, 6-24=1944/1051, 6-7=2378/1073,
7-25=2051/885, 8-25=2094/879, 8-9=265/151
BOT CHORD 17-18=116/283, 3-15=272/250, 14-15=-791/1950, 13-14=-543/1440, 12-13=823/1885,
10-11=278/383, 9-10=112/270
WEBS 1-17=809/1376, 2-17=866/643, 15-17=339/962, 2-15=489/915, 4-14=649/497,
5-14=550/1029, 5-13=250/575, 6-13=364/322, 6-12=-169/401, 8-10=1185/779,
8-12=653/1699, 8-11=485/510
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2). Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; eave=oft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-2-15, Interior(1) 3-2-15 to 16-7-0, ExtePior(2) 16-7-0
to 19-8-3, Interior(1) 19-8-3 to 31-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 493 lb uplift at joint 18 and 532 lb uplift at
joint 10.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M I-7473 rev. 101031201E BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Ind Mdual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for slablifty and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/1 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
.�`%%�P 1J- 0GAF oe
`QV '� G E N 8 �qif,'♦
� V F ♦♦
No 58126 So
•
♦ Si• OR1•
-B ONA` S %%'
Philip J. O'Regan PE No.58126
MITek USA, Inc. R. Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MR
MITek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
T15924375
506926
D7
Roof Special
�Qty
i
1
Job Reference (optional)
ibbetts Lumber cc, Palm Say, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:13 2019 Page 1
ID:zNgPoPtcZMR2Gpw0bQfmsEy71ZM-dmNtz kdYTWXkYV2sz2DffyNGXECyDjdeS6SJazzM7K
5-10-0 11-8-0 16-7-0 215-8 26�-0 28.8-3 31-0-0
5-10-0 5-10-0 4-11-0 4-101 4-10 8 2 4-3 2 3-13
5.00 12
4x8 =
Scale = 1:54.1
3x6 11 4x8 = 2x4 11 4x4 =NOP2X STP = 3x4 =
4x12 = 2x4 II
2x4 II
5-10-0 12-M
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL)
-0.19 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.71
Vert(CT)
-0.38 12-13 >892 240
BCLL 0.0
Rep Stress [nor YES
WB 0.70
Horz(CT)
0.14 9 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.25 12-13 1 >999 240
Weight: 182 lb FT = 20%
LUMBER-
BRACING-
1
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-1-14 oc purlins,
BOT CHORD 2x4 SP No.2
except end verticals, and 2-0-0 oc purlins (3-5-1 max.): 1-3.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 18=1049/Mechanical, 9=1234/0-7-10
Max Horz 18=-213(LC 12)
Max Uplift 18=-486(LC 12), 9=539(1_C 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-18=996/650, 1-22=1224/707, 22-23=-1224707, 2-23=-1224/707, 2-3=-2374/1251,
3-24=2722/1467, 4-24=-2673/1477, 4-25=-1847/1038, 5-25=1902/1023, 5-6=2380/1079,
6-26=2052/889, 7-26=2094/882, 7-8=-265/151
BOT CHORD 13-14=468/1412, 12-13=-549/1440, 11-12=-833/1884, 9-10=278/384, 8-9=112/270,
14-16=01254, 3-14=1294/838
WEBS 1-17=855/1485, 2-17=949/639, 14-17=-350/1136, 4-14=-749/1451, 4-12=218/563,
5-12=369/320, 5-11=161/405, 7-9=-1185/783, 2-14=-595/1265, 7-11=653/1699,
7-10=-490/511
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-2-15, Intedor(1) 3-2-15 to 16-7-0, Exterior(2) 16-7-0
to 19-8-3, Interior(1) 19-8-3 to 31-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for'reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed fora live load of 20.00sf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 486 lb uplift at joint 18 and 539 lb uplift at
joint 9.
9) Graphical purlin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord.!
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED 89TEK REFERENCE PAGE MI-7473 rev. 1010312015 BEFORE, USE
Design valid for use only with MiTek® connectors.. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rF11 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
T
v
111111111111
J. O'qF
♦•`Q�Z\\: E '�G NS
No 58126
S F�411�
i,��ss,10 N A;
111
Philip J. O'Regan PE No.58126
MI7ek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MR
MiTek°
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
GopherRidge CourtyardT15924376
Tty
506926
DSRoof
Special
1
Job Reference (optional)
ibbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:14 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-5yxGBKIFJmeOMi4EQgZSCVWZNwYUhcgmt6rOrOzzM7J
4-11-12 9-8-0 12 8 0 16 7-0 21-5 8 26 4-0 28 8 3 31-0-0
411-12 4-8 4 3-0-0 3-11-0 4-10 8 4-10-8 2-4-3 2-3-13
4x4 =
5.00 12
Scale = 1:53.9
6x6 = 6x8 = 2x4 II 4x4=NOP2XSTP = 3x4 =
2x4 11
9-8-0 1210 19-6-0
26.4-0 268-3 29r 030 1-0-0
9-8-0 3-0-0 6-10-0
6-10-0 2 4 3 0.- 3�2-0 0�
Plate Offsets (X,Y)— [8:0-4-0,0-2-0], [12:0-2-4,0-2-4], [14:0-2-0,0-2-12]
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.41
Vert(LL)
-0.22 16-17 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Vert(CT)
-0.47 16-17 ! >723 240
BCLL 0.0
Rep Stress Incr YES
WB 0.91
Horz(CT)
0.15 10 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL)
0.20 13-14 >999 240
Weight: 175 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-6-10 oc purlins,
BOT CHORD 2x4 SP No.2
except end verticals, and 2-0-0 oc purlins (3-10-6 max.): 1-3.
WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 17=1049/Mechanical, 10=1234/0-7-10
Max Horz 17=-168(LC 12)
Max Uplift 17=-480(LC 12), 10=545(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2=3=2099/1117, 3-4=-2385/1276, 4-23=-2426/1372, 5-23=-2384/1382, 5-24=-1841/1039,
6-24=189811025, 6-7=2383/1094, 7-25=-2053/901, 8-25=-2095/895, 8-9=265/151
BOT CHORD 16-17=611/1329, 4-14=-229/257, 13-14=-552/1438, 12-13=836/1882, 10-11=-278/384,
9-10=112/270
WEBS 2-17=1547/965, 2-16=-379/948, 3-16=-1071/628, 14-16=-926/2234, 5-14=683/1215,
5-13=211/556, 6-13=372/325, 6-12=-163/412, 8-10=-11851785, 8-12=658/1702,
8-11=489/509
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; eave=4ft; Cat.
gust)
lonal) and C-C Exterior(2)0
�,
R��q,��j
to 19 8 3, ntelriGC)19-8 3 to 0-0 zone cantileverr left and posed ;C-C for members s and forces & MWFRS or reach ns7
Lumber DOL=1.60 DOL=1.60
���,•r\P r E N SF�' �i�
shown; plate grip
:2
3) Provide adequate drainage to prevent water ponding.
No 58126 •
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
=
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 480 lb uplift at joint 17 and 545 lb uplift at
• I3 S 411 Z.
joint 10.
9) Graphical does depict the size or the orientation of the along the top and/or bottom chordj
i�` R `O Q;; \�,�Z
G
purlin representation not purlin
'
s
�S'0
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,&WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED mrrEK REFERENCE PAGE MI-7473 rev. 10/02,2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the ovemlll
indicated Is to buckling individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
building design. Bracing prevent of
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rP/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss Type
Ply
Gopher Ridge Courtyard
Puss
JQt`y
T75924377
506926
Roof Special
1
1
Job Reference (optional)
ibbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:15 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-Z8UeOgmt44mF sfR_OShlj2fvKyNQ97v6mbZNSzzM?I
7-8-0 12-1-8 16-7-0 1 23-5.10 31-0-0
7-8-0 4-5 8 4-5 8 6-10-10 7.65
5x6 =
5.00 12
Scale = 1:53.2
12 11 .- -. -- - 8
3x6 I I 6x8 = 5x6 = 3x4 = NOP2X STP = 3x4 =
4x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in (loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.75
Vert(LL) -0.17 10-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(CT)-0.32IG-11 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.58
Horz(CT) 0.05 8 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.22 10-11 >999 240
Weight: 163 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-4-2 oc purlins, except
1-2: 2x4 SP SS end verticals, and 2-0-0 oc purlins (3-2-15 max.): 1-2.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.2 WEBS 1 Row at midpt
1-11, 5-8
REACTIONS. (lb/size) 12=1049/Mechanical, 8=123410-7-10
Max Horz 12=-171(LC 10)
Max Uplift 12=-476(LC 12), 8=549(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-12=972/632, 1-16=2530/1346, 16-17=-2530/1346, 2-17=-2530/1346, 2-3=-2806/1536,
3-18=1590/938, 4-18=1507/951, 4-19=-1492/892, 5-19=-1573/882, 6-7=288/61
BOT CHORD 10-11=799/1745, 10-21=-471/1213, 21-22=-471/1213, 9-22=471/1213, 8-9=-662/1420,
7-8=24/280
WEBS 1 -11 =1 342/2548, 2-11 =-I 370/896, 3-11=-571/1099, 3-10=-616/457, 4-10=335/764,
4-9=134/360, 5-8=1675/1050, 6-8=-213/303
NOTES-
1) Unbalanced roof live loads have been considered for this design.
,,I(,11111//��
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; ea've=4ft; Cat.
�� , 0, �'r
FRS O
nal) and C-C right(exposed:C-C reach
E9 31-0-0 cantileverr
to 8 3, ntelriD (1)19-8 3 to zone; left and for members s and forces & MWFRS or ns7
Lumber DOL=1.60 DOL=1.60
�%%',X\ -A G E N
Q : V� SF•••? �i
shown; plate grip
��
3) Provide adequate drainage to prevent water ponding.
NO 58126
•;
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
* ,
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Refer to girder(s) for truss to truss connections.
8) truss to bearing 476 lb 12 549 lb
Provide mechanical connection (by others) of plate capable of withstanding uplift at joint and uplift at
8.
joint
depict
�i�F • ':
9) Graphical purlin representation does not the size or the orientation of the purlin along the top and/or bottom chord;
•' �\
•,�S'S�0
N AL
nl
Philip J. O'Regan PE N0.58126
MITak USA, Inc. FL Cert 6534
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,&WARNING - Verify design parameter: and READ NOTES ON THIS AND INCLUDED MTTEK REFERENCE PAGE Ml1.7473 rev. 101=015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not •
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall)
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/11"P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa,FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924378
506926
D10
Roof Special Girder
1
1
Job Reference (optional)
moans Lumoer co, vaim may, rL' Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:17 2019 Page 1
ID:zN9PoPtcZMR2Gpw0bQfmsEy71ZM-VXcOpMn8bhlyD9pp5o79g873V8ZKu?vCZ44gSLzzM?G
5 8-0 11-1-8 16-7-0 21-2-1 25-9-2 31-0-0
5-8-0 M-6 5-5 8 4-7-1 47-1 5-2-14
Scale = 1:53.2
4x4 =
3x6 11 5x6 = 4x4 = 5x8 = 3x4 = NOP2X STP = 3x4 =
4x4 =
5-8-0 11-1-8 16-7-0 22-11-2 28-8-3 29 O 0 31 0 0
5 8-0 5-5-8 5-5-8 6-4-2 - 5 9-1 0- - 3-
Plate Offsets (X,Y)—
[11:0-4-0,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL) -0.19 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT) -0.35 12-13 >981 240
BCLL 0.0
Rep Stress Incr NO
WB 0.81
Horz(CT) 0.07 9 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL) 0.25 12-13 >999 240
Weight: 169 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP No.2 "Except'
1-2: 2x6 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.2
REACTIONS. (lb/size) 14=874/Mechanical, 9=121610-7-10
Max Horz 14=-184(LC 6)
Max Uplift 14=-631(LC 8), 9=569(LC 8)
Max Grav 14=1039(LC 36), 9=1216(LC 1)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-8-12 oc purlins,
except end verticals, and 2-0-0 oc purlins (4-2-14 max.): 1-2.
BOT CHORD Rigid ceiling directly applied or 4-8-1 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-14=918/571, 1-18=2939/1647, 18-19=-2938/1647, 19-20=2937/1648, 2-20=2936/1648,
2-3=2039/1068, 3-4=-1346/748, 4-5=-1332/751, 5-6=-1510/759
BOT CHORD 14-21=180/298, 21-22=-180/298, 13-22=-180/298, 12-13=-1611/3132, 11-12=847/1899,
10-11=567/1369, 9-10=-516/1137
WEBS 1-13=1595/2891, 2-13=-755/436, 2-12=-1278f791, 3-12=-138/448, 3-11=-901/527,
4-11=367/740, 5-11=-324/217, 6-1 0=-1 9/289, 6-9=-15351760
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=31ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6), ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 631 lb uplift at joint 14 and 569 lb uplift at
joint 9.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 58 lb down and 30 lb up at
1-10-12, and 58 lb down and 30 lb up at 3-10-12 on top chord, and 99 lb down and 165 lb up at 1-10-12, and 99 lb down and 165 lb
up at 3-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (p[Q
Vert: 1-2=54, 2-4=-54, 4-8=-54, 14-15=-20
Q, WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERENCE PAGE 01.7473 rev. 1010312015 BEFORE USE
Design valid for use only with MrekO con rectors., This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and pro pedy Incorporate this design Into the overall;
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
NV
E IV
No 58126
� r
S F :�Z
i
OR1 �
,0 N A' S�C? '�
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6M Parke East Blvd. Tampa FL M610
Date:
January 3,2019
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
} 9
Job
Truss
Truss Type -
My
Ply
Ridge Courtyard
506926
D10
Roof Special Girder
1
FGobher
Reference (optional)
ID:zNgPoPtcZMR2GpwObQfmsEy7lZM-VXcOpMn8bhlyD9pp5o79g873V8ZKu?vCZ44gSLzzM?G
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 19=15(B) 20=15(B) 21=82(B) 22=82(B)
ter.
AWARNING • Ve ft design paternal and READ N07ES ON THIS AND INCLUDED WTEK REFERENCE PAGE MI.7473 rev. 10/03,2015 BEFORE USE. ME
building Design valid for use only with Mn`ek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall'
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek°
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the i
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T75924379
506926
D11
Common
1
1,
Job Reference (optional)
iooeus Lumoer uo, vaim bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:17 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-VXcOpMn8bhlyD9pp5o79g872LBdnuylCZ44gSLzzM?G
6-0-0 125-0 19-3-10 26-10-0
6-4-4 6-0-12 6-10-10 75-6
4x6 =
3x4
Scale = 1:45.7
6
l
Iv
r
9 18
19
8
o
e
10
NOP2X STP =
3x4 =
5x6 =
7
NOP2X STP = 3x4 =
6x6 =
3x4 =
84-6
16-55
24-6-3
241q-026-10-0
84-6
8-0-14
8-0-14
- 3 2-0-0
Plate Offsets (X,Y)—
[8:0-3 0,0-3-01
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TIC 0.56
Vert(LL)
-0.16
8-9
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.67
Vert(CT)
-0;24
8-9 !
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.98
Horz(CT)
0.04
7
n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Wtnd(LL)
0.08
8-9
>999
240
Weight: 137 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 *Except* BOT CHORD
1-10: 2x6 SP No.2
REACTIONS. (lb/size) 10=890/0-7-10, 7=1078/0-7-10
Max Horz 10=-184(LC 10)
Max Uplift 10=-401(LC 12), 7=483(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-14=250/199, 2-15=1272/764, 3-15=-1204/782, 3-16=-1150/700, 4-16=1232/690,
5-6=328/48, 1-10=223/257
BOT CHORD 9-10=569/1274, 9-18=319/897, 18-19=-319/897, 8-19=-319/897, 7-8=541/1158,
6-7=19/314
WEBS 2-9=220/296, 3-9=180/479, 3-8=-104/408, 4-8=-180/256, 2-10=-1184/634,
4-7=1362/943, 5-7=202/310
Structural wood sheathing directly applied or 4-2-6 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=27ft; ea,ve=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-2-12 to 3-2-12, Interior(1)3-2-12 to 12-5-0, Exterior(2) 12-5-0
to 15-5-0, Interior(1) 15-5-0 to 26-10-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 401 lb uplift at joint 10 and 483 lb uplift at
joint 7.
AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED Ng7EK REFERENCE PAGE M I-7473 rev. 1010312016 BEFORE USE
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall;
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
,�Iflllll//II
,,`%\.. OrgF��,��
GENS
No 58126
�-10 ;��
13O ST F :��[/� .
,'�,��`S,' c4 O R \ � P' GN��,
i,`S/O N A S�w��
Phlllp J. O'Regan PE No.58126
MITek USA,Inc. FL Cart 6634
6904 Parke EW Blvd. Tampa FL 33610
Date:
January 3,2019
Iff
MiTek'
6904 Parke East Blvd.
Tampa, FL 36810
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15824380
506926
D12
Common
1
1�
Job Reference (optional)
> w,nb., C.. raim Say. FL Run: B.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:18 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-zjAmOiomM?9prJO?fWeOMMgDUY_2dRgMokgD_rizzM?F
2-313 7-6-6 1450 21-310 26-fr3 2NOT
2-313 5.2-9 6-10-10 B-10.10 5-2-9 2-313
Scale = 1:47.3
4x6 =
Iq
0
3x4 = NOP2X STP = bXtJ = 5x6 = NOP2X STP = 3x4 =
3x4 = 3x4 =
r 2-00.0 2-3.13
10-4-10
18-5-6
26-6-3
260; 0 2B•10.0
' 0 0.3.13
8-0-13 '
B-0-13
8-0-13
0.}13 2-0_0
Plate Offsets (X,Y)—
[1:0-1-14,0-0-2],[9:0-3-0,0-3-0],[10:0-3-0,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(LL)
-0.15
9-10
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(CT)
-0.25
9-10
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.84
Horz(CT)
0.04
8
file
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.08
9-10
>999
240
Weight: 142 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-3-14 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 11=1067/0.7-10, 8=1067/0-7-10
Max Horz 11=202(LC 11)
Max Uplift 11=-573(LC 12), 8=475(1_C 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=320/49, 3-19=12101654, 4-19=1128/665, 4-20=-1128/665, 5-20=1210/654,
6-7=320/49
BOT CHORD 1-11=20/306, 10-11=507/1241, 10-22=-283/888, 22-23=-283/888, 9-23=283/888,
8-9=507/1138, 7-8=20/306
WEBS 4-9=102/413, 5-9=180/254, 4-10=-96/413, 3-10=180/250, 3-11=-1339/908,
2-11=204/311, 5-8=1339/908, 6-8=204/311
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; ea've=4ft; Cat.
�1111111/
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-5-0, Exterior(2) 14-5-0 to
17-5-0, Interior(1) 17-5-0 to 28-10-0 left for members forces & MWFRS for reactions
0,
\Q RF �j
zone; cantilever and right exposed ;C-C and
shown; Lumber DOL=1.60 plate grip DOL=1.60 �
%
��
•�,\ S•'.?
3) All plates are MT20 plates unless otherwise indicated.
�� Q : �i
F
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
No 58126
•;
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
fit between the bottom BCDL = 10.Opsf.
:
* ;
will chord and any other members, with
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb uplift at joint 11 and 475 lb uplift at
joint 8.
�p •
S
OPO N A11
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cent 6634.
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,A, WARNING - Verify design parameters and READ NOTES oN TNIS AND INCLUDED mTTEK REFERENCE PAGE 89I.7473 rev. IOM312015 BEFORE USE
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an Ind Mdual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TP/1 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924381
506926
D13
Hip
1
1'
Job Reference (optional)
wum,n u,mva, w, Faun Bay, FL Run: 8.240 s Dee 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:19 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy7lZM-Rwk9E2pO7JHgSTzCDD9dvZCQoxLeMO6V1OZnWDzzM7E
2-3-13 7-7-15 13-0-0 15-10-0 21.2.2 26.8.3 28-10.0
2.3-13 5-4-2 5-4.2 2-10-0 5.4-2 5-4-12 2-3-13
4�
0
Scale: 1/4"=1'
4x4 =
4x4 =
3x4 =
NOP2X STP = 4x4 = 5x6 = 3x4 = 4x4 = NOP2X STP = 3x4 =
2x4 11
5.4.2
2x4 11
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017ffP12014
CSI.
TC 0.43
BC 0.45
WB 0.38
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl L/d
-0.11 10-11 >999 360
-0.17 10-11 >999 240
0.02 9 n/a n/a
0.09 12-13 >999 240
PLATES GRIP
MT20 244/190
Weight: 149 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD Structural wood sheathing directly applied or 5-0-15 cc purlins, except
BOT CHORD 2x4 SP No.2
2-0-0 cc purlins (5-11-12 max.): 4-5.
WEBS 2x4 SP No.2
BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing.
REACTIONS. (lb/size) 14=1067/0-7-10, 9=1067/0-7-10
Max Horz 14=-182(LC 10)
Max Uplift 14=-573(LC 12), 9=475(1_10 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-21 =1 2971707, 3-21 =1 243/723, 3-22=1100/699, 4-22=-1038/715, 4-23=958/710,
23-24=958/710, 5-24=958/710, 5-25=-10331714, 6-25=1095/698, 6.26=11981722,
7-26=12981707
BOT CHORD 13-14=157/250, 12-13=-561/1240, 11-12=-379/978, 10-11=549/1148
WEBS 3-12=306/213, 6-11=311/212, 2-13=-766/1190, 2-14=959/766, 7-10=765/1192,
7-9=9601765
NOTES-
1) Unbalanced roof live loads have been considered for this design
($.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-0-0, Exterior(2) 13-0-0 to
% t%J1111111111
,I��
20-0-15. Interior(1) 20-0-15 to 28-10-0 left exposed for members and forces & MWFRS for reactions
Q,
So! \Q AF
zone; cantilever and right ;C-C
shown; Lumber DOL=1.60 DOL=1.60
�`N • G E N •• �'9 ��•
plate grip
3) Provide adequate drainage to prevent water ponding.
��� -*
�� Q : •�� SF•' �2 •i
4) All plates are MT20 plates unless otherwise indicated.
%
iv O 58126
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
• designed for live load 20.Opsf the bottom in 3-6-0 tall by 2-0-0
•
*
6) This truss has been a of on chord all areas where a rectangle wide
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
,•
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb upl'rft at joint 14 and 475 Ib uplift atir
joint 9.
8) Graphical representation does not depict the size or the orientation of the along the top and/or bottom chord.
i ', F 4/
purlin purlin
••••O,�••;��
\�%
o R,0P;
AL E�C�,.
n1
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Bert 6634.
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED A97EK REFERENCE PAGE h91-7473 rev. 10103/2015 BEFORE USE '
Design valid for use only with MTek® connectors.. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated (s to prevent buckling of Individual truss web andlor chord members only. Additional temporary antl permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI11"P/1 quality Criteria, DSB-89 andBCS/ Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
T15924382
506926
D14
Hip
�Qty
7
1
Job Reference (optional)
Timms LUrnber co, Palm Bay. FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:20 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-v61XROpOucPX4dYOmxgsSnlWBLeX5SBeF2JK2gzzM7D
2-3-13 5-9-14 11-0.0 17-10.0 23-0.2 26-6-3 28.10-0
2-3-13 3-8.1 5-2-2 610-0 5.2-2 3.6-1 2-3.13
4x8 =
4x6 =
Scale: 1/4"=l'
3x4 — NOP2X STP — 5x6 = 3x8 = NOP2X STP = 3x4 =
—
3x4 =
3x4 =
2-0.0 2- - 3 11.0.0
17-10.0
26-6.3 26 1 0 26-10-0
2-0-0 8-8-3
6-10-0
8-8-3 0. 3 2-0.0
Plate Offsets (X,Y)—
[1:0-1-14,0-0-2), [4:0-5-4,0-2-0), [11:0-3-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.71
Vert(LL) -0.13
9-10 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.66
Vert(CT) -0.26
9-10 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.39
Horz(CT) 0.04
9 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.07
10-11 >999 240
Weight: 144 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-1-14 oc purlins, except
BOT CHORD 2x4 SP No.2
2-0-0 oc purlins (4-1-0 max.): 4-5.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-D-0 oc bracing.
REACTIONS. (lb/size) 12=1067/0-7-10, 9=1067/0-7-10
Max Horz 12=154(LC 11)
Max Uplift 12=-573(LC 12), 9=475(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=367/49, 2-19=259/3, 3-20=1222/742, 4-20=1169/758, 4-21=1081/774,
21-22=10811774, 5-22=10811774, 5-23=1168/758, 6-23=1221/742, 6-24=251/64,
7-24=261/0, 7-8=369/45
BOT CHORD 1-12=25/354, 11-12=566/1045, 10-11=-493/1078, 9-10=-554/1010, 8-9=22/356
WEBS 3-12=1266/1053, 2-12=-140/267, 6-9=-1262/1056, 7-9=-139/268
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=29ft; eave=oft; Cat
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0.0 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Exterior(2) 11-0-0 to
15-2-15, Interior(1) 15-2-15 to 17-10-0, Exterior(2) 17-10-0 to 22-0-15, Interior(1) 22-0-15 to 28-10-0 zone; cantilever left'and right
, Q, �4.
exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to water
�� \Q
E ••
prevent ponding.
4) All plates are MT20 plates unless otherwise indicated.
\ 0 N,9
Q V IS i
5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
No 58126
•:
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
fit between bottom
* ;�
will the chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb uplift at joint 12 and 475 lb uplift at
joint 9.
'p
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord!
F
%%
Philip J. Q'Regan PE No.56126
MITek USA, Inc. FL Gert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING- Verify design parameters end READ NOTES ON THIS AND INCLUDED AVTEK REFERENCE PAGE 01-7473 rev. 10103 2015 BEFORE USE
"
Design valid for use only with WOO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MITOW
prevent
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITP11 Qualify Criteria, DS8-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924383
508926
D15
Hip Girder
1
1
Job Reference (optional)
s Lunioar C.. Faun Bay, FL Run: 8.240 s Dec 62018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:22 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfr isEy71ZM-sVQHs3rGQEfFJxhnuMjKXCqux9JYZLPxjMoR7YzzM7B
2-3-13 9.0-0 14-6.0 19.10.0 26.6-3 28.10.0
2.3-13 6-8-3 5-5-0 5-5.0 6-8-3 2.3-13
6x6 =
2x4 11
6x6 =
Scale: 1/4'=l'
12 -i-i lu e 8
3x4 —
NOP2X STP = 4x4 = 5x8 = 4x4 = NOP2X STP = 3x4 =
2x4 11 2x4 11
6.8.3
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017lrP12014
CSI.
TC 0.57
BC 0.76
WB 0.48
Matrix -MS
DEFL, in
Vert(LL) -0.08
Vert(CT) -0.17
Horz(CT) 0.03
Wind(LL) 0.10
(loc) Vdefl Ud
9-10 >999 360
9-10 >999 240
8 n/a n/a
10 >999 240
PLATES GRIP
MT20 244/190
Weight: 152 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-7-2 oc purlins, except
3-5: 2x6 SP No.2
2-0-0 oc purlins (4-10-9 max.): 3-5.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 7-5-6 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 12=1390/0-7-10, 8=1390/0-7-10
Max Horz 12=-126(LC 6)
Max Uplift 12=-704(LC 8), 8=606(LC 8)
Max Grav 12=1401(LC 32). 8=1401(LC 31)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2044/813, 3-19=2248/908, 4-19=-2249/908, 4-20=-2249/908, 5-20=2248/908,
5-6=2044/828
BOT CHORD 11-12=126/282, 11-21=-610/1888, 21-22=-610/1888, 10-22=610/1888,
10-23=624/1809,
23-24=624/1809,9-24=-624/1809
WEBS 2-11=635/1731, 3-11=59/365, 3-1 0=-1 20/611, 4-10=-368/267, 5-10=104/611.
5-9=59/352, 6-9=560/1734, 2-12=1322/760, 6-8=1321/704
NOTES -I
,11111111/II/
) Unbalanced roof live
Wind:4ft; Cat.
loads(directional);
���F�2)
grip OL=1.60
Exp CEncl.,Gp08; MWFRS cailevereft d right a exposed DOL=160
Ptl;
,,%
d`.• 1
pate
3) Provide adequate drainage to water
CEN .
SF••.?
prevent ponding.�
4) All plates are MT20 plates unless otherwise indicated.
ft No 581215
•;
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
• bottom in 3-6-0 tall by 2-0-0
*
6) This truss has been designed for a live load of 20.Opsf on the chord all areas where a rectangle wide
'
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 704 lb uplift at joint 12 and 606 lb uplift at
�p ;
joint 8.
i O F �
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) device(s) be to support concentrated load(s) 72 lb down and 144 lb up at
�•
or other connection shall provided sufficient
9-0-0, and 72 lbdown and 144 lb up at 19-10-0 on top chard, and 331 lb down and 144 lbup at 9-0-0, 69 lbdown at 11-0-12, 69 lbdown
��j�` S ••. I� \ ••�`��
13-0-12, 69 lb down lb 17-9.4, and 331 lb down and 144 lb up at 19 9 4
���
.......
�js
at at wn at
onnect
on bottom chord. The design/selection0of such c9 on device(s) is the responsibility ponsibil� f others,
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
Philip J. O'Regan PE No.58126
LOAD CASE(S) Standard
MITek USA, Inc. R. Gert 6634
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
69M Parke East Blvd. Tampa FL 33610
Uniform Loads (plf)
Date:
Vert: 1-3=54, 3-5=54, 5-7=54, 13-16=-20
January 3,2019
®WARNING - Ve ft design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGENet-7473 rev. 10/03/2015 BEFORE USE
Design valid for use only with MiTekO connectors.. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into tha overall
building design. Bracing Indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
WOW
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rFI1 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA22314.
Tampa,. FL 36610
t
Job
Truss
Truss Type -
Qty
Ply
Gopher Ridge Courtyard
�
T15924363
506926
D15
Hip Girder
1
1
Job Reference (optional)
mun: c. u s uec o zu io rnm: o.zqu s uec is zula mi i eK mcusmes, mc. vvec dan z lo:za:zz zuia rage z
ID:zNgPOPtcZMR2GpwObQfmsEy71 ZM-sVQHs3rGQEfFJxhnuMjlO(Cqux9JYZLPxjMoR7YzzM7B
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 3=-44(B) 5=-44(B) 11=-172(B) 10=-43(B) 9=172(B) 21=-43(B) 22=-43(B) 23=-43(B) 24=-43(B)
r.�
A, WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED AMEK REFERENCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual build Ing component, not,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSh TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. i Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
copharRidgacourtyard
T15924384
506926
E1
Hip Giber
1
1
Job Reference (optional)
ribbetts Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:23 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfnisEy71ZM-Khzf3PsuBXn6x5GzS3EZ3PN3WLkglvD5xOX_f zzM7A
2-3-13 5-0-0 9.0-0 10-11-13 14-0-0
23-13 2-83 4-M 1-11-13 3-03
Scale = 1:23.0
44 =
4x8 =
NOM STP = NOP2X STP =
2x4 11
2-0-0
2x4 II
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.51
BC 0.44
WB 0.06
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) Vdefl Ud
0.13 8-9 >819 240
0.14 8-9 >718 180
0.01 7 rile n/a
PLATES GRIP
MT20 244/190
Weight: 57 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2
2-0-0 oc purlins (6-0-0 max.): 3-4.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (Ib/size) 10=336/0-7-10, 7=395/0-7-10
Max Horz 10=66(LC 7)
Max Uplift 10=-593(LC 8), 7=537(LC 8)
Max Grav 10=488(LC 39), 7=488(LC 37)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=301/352, 2-3=308/393, 3-17=249/353, 17-18=249/353, 18-19=249/353,
4-19=249/353, 4-5=315/391, 5-6=311/353
BOT CHORD 1-10=349/313, 9-10=360/296, 9-20=-332/318, 8-20=332/318, 7-8=327/312,
6-7=327/312
WEBS 2-10=261/323, 5-7=286/315
NOTES-
1) Unbalanced roof live loads have been considered for this design
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
Encl., GCpi=0.18; MWFRS left and right exposed left exposed; Lumber DOL=1,60
�1111111/
DOL 1 ; (directional); cantilever ; porch plate grip
p'S
�
3) Provide adequate drainage to prevent water ponding.
Indicated.
�%%,,`j`\�'• E IV • •• �'9 ���
,Q �.� S4S 41 L �.0
4) All plates are MT20 plates unless otherwise
��
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
No 58126 y
•:
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
*
will fit between the bottom chord and any other members.
:•
7) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 593 lb uplift at joint 10 and 537 lb uplift at
joint 7.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
device(s) be to concentrated load(s) 196 lb down and 175 lb up at
F (V
9) Hanger(s) or other connection shall provided sufficient support
5-0-0, and 79 lb down and 65lb up at 7-0-12, and 196lb down and 175lb up at 9-0-0 on top chord, and 169 lb down and 242 lb up
�j T• .� Q` ' _ ��
at 5-0-0, and 77 lb up at 7-0-12, and 169 lb down and 242 lb up at 8-11-4 on bottom chord. The design/selection of such
�i�, s ' 0 R •'•`Cj\
connection device(s) is the
���
10) In the LOAD CASE(S)sect on, loads)applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Philip J. O'Regan PE No.58126
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
MITek USA, Inc. FL Cert 6634
Uniform Loads (plf)
6904 Parke East Blvd. Tampa FL 33610
Vert: 1-3=-54, 3-4=-54, 4-6=-54, 11-14=-20
Date:
January 3,2019
WARNING —Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MI.7473 rev. 10/0/2015 BEFORE USE
Design valid for use only with MiTeM connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
is buckling individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
building design. Bracing indicated to prevent of
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rP/1 quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss -
Truss Type
Ply
Gopher Ridge Courtyard
T15924384
506926
E1
Hip Girder
�Qty
1
1
Job Reference (optional)
_,..... _,.,... ...... ..r ,
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 3=27(B)4=27(B)9=114(B)8=114(B)18=-0(B)20=24(B)
zu is mi 1— mausrnes, .— vvea — z io:za:zn zuiw rage z
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-otX2H ItXyrvzZEr9?mlocdwEGy4vl MTEAgHYBRzzM?9
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED NBrEK REFERENCE PAGE MI-7473 rev. I0IM015 BEFORE USE.
Design valid for use only with MITek® connectors.. This design is based only upon parameters shown, and is for an individual building component, not;
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTele
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrP/I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T75924385
506926
F2
Common
1
1
Job Reference (optional)
Kun: a.z4u s uec o zura vnm: a.z4u s uec is zuia mu eK atausines, Inc. wea aan Z t15:z9:Z0 Zulu Page t
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-G35QU5t9j91 gAOQMZUG19gSSvMH2mojOPK05ktzzm?B
7.0-0 1113-10
7-0-0 4-3-10
4x4 =
NOP2X STP = NOP2X STP =
2-0-0 2rs413 11-3-10 4x8 =
r 2-0-0 -1 8-11-13
Scale = 1:21.5
Plate Offsets (X,Y)—
[1:0-1-14,0-0-2)
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vdefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL)
0.43
5-6
>242
240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.90
Vert(CT)
-0.27
5-6
>396
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.12
Horz(CT)
-0.00
5
file
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 64 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 *Except* BOT CHORD
4-5: 2x6 SP No.2
REACTIONS. (lb/size) 6=518/0-7-10, 5=301/0-7-10
Max Horz 6=77(LC 11)
Max Uplift 6=-498(LC 12), 5=297(1-C 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=150/314, 2-10=138/391, 10-11=-131/395, 3-11=-129/405, 3-12=124/393,
12-13=130/386, 4-13=149/384, 4-5=-155/304
BOT CHORD 5-6=310/195
WEBS 2-6=278/206
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 2-3.13 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0.0 to 3-0-0, Interior(1) 3-0-0 to 7-0-0, Exterior(2) 7-0-0 to
10-0-0, Interior(1) 10-0-0 to 11-0-14 zone; cantilever left and right exposed ; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 498 lb uplift at joint 6 and 297 lb uplift at
joint 5.
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED IWTEK REFERENCE PAGE M I-7473 rev. 10/03/2015 BEFORE USE
Design valid for use only with Mi rek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlf Quality Criteda, DSB-99 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
1111111111111.,
��Q�
J. O'qF
J�Q'rN '� G E N S
No 58126
�O OF
40
O R Epp' N
ON
Al
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MF
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924386
506926
E3
Jack -Open Supported Gable
1
1
Job Reference (optional)
r . nun: 6.z4u s uec 6 zuta vnni: 6.z4u s uec 18 zuiu MfTek Industries, Inc. Wed Jan 2 16:29:26 2019 Pagel
ID:zNgPoPtcZMR2GpwObQfm'sEy71 ZM-kGfoiRunUSghoY7Y7BnGh27UimrYVGgXe_meGJzzM77
-24)-0 i 1-"
2-M 1-M
3
3x6 II 2x4 II
Scale: 1"=l'
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.90
Vert(LL) 0.01
1 n/r 120
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.05
Vert(CT) -0.01
1 n/r 120
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-R
Weight: 11 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 1-6-0 cc purlins, except
BOT CHORD 2x4 SP No.2
end verticals.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. (lb/size) 5=263/1-6-0, 4=-58/1-6-0
Max Horz 5=100(LC 12)
Max Uplift 5=-263(LC 12), 4=58(LC 1)
Max Grav 5=263(LC 1), 4=65(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-5=233/782
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) -2-0-0 to 1-0-0, Exterior(2) 1-0-0 to 1-4-4 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSIrrPI 1.
3) Gable requires continuous bottom chord bearing.
4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 263 lb uplift at joint 5 and 58 lb uplift at
joint 4.
,& WARNING -Verify design parameters and READ NOTES ON 77iIS AND INCLUDED mrrEK REFERENCE PAGE iwi-7473 rev. 10102/2015 BEFORE USE
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not,
a truss system. Before use, the building designer must verify the applicabilky of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteda, DSB-89 and BCSI Bulldirig Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
,�11111111//ICI
,%%%!
i
No 58126
r •
:p0: OF �
-Ss ONA 'E %%%
nn
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
Id!
MfTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qly
er Ridge courtyard
T15924387
506926
E4
Jack -Open
1
r7Jb
Reference (optional)
Go, raim nay, FL ;8.240 s Dec 18 2018 MTek Industries, Inc. Wed Jan 2 16:36:36 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-8_eMyT5VDaKgOdtBJW56jpl x6aPFkggWtwPMOzzLuP
-21-0 1 6 0
2-0-0 1 6 0
5.00
N m
m
2x4 I PROVIDE ANCHORAGE, DESIGNEDBYOTHERS,
4 AT BEARINGS TO RESIST MAX. UPLIFT
2x4 k1 AND MAX HORZ. REACTIONS
SPECIFIED BELOW.
Scale = 1:22.2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL) 0.01
5 n/r 120
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.16
Vert(CT) -0.01
5 n/r 120
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB 0.03
Horz(CT) 0.00
n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Weight: 19 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 1-6-0 oc purlins, except
BOT CHORD 2x4 SP No.2
end verticals.
WEBS 2x6 SP No.2 !Except*
BOT CHORD
Rigid ceiling directly applied or 6-0.0 cc bracing.
2-5: 2x4 SP No.2
REACTIONS. (lb/size) 3=213/Mechanical, 4=0/Mechanical
Max Horz 3=99(LC 1), 4=227(LC 12)
Max Uplift 3=-254(LC 12)
Max Grav 3=213(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-7=322/150, 3-7=319/171
BOT CHORD 5-6=219/282
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-0-0 to 1-0-0, Interior(1) 1-0-0 to 1-5-14 zone; cantilever left
exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) The Fabrication Tolerance at joint 2 = 12%
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb)
3=254.
, & WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE MI.7473 rev. 101031201E BEFORE USE.
Design valid for use only with IV7ek0 connectors. This design Is based only upon parameters shown, and is for an Individual building component, not;
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
��II/111111j1
J, O'/�
.......
�. • �. F ..0
No 58126
� r
OF •: J
��i FS • . O R \
A' ,%
Philip J. D'Regan PE No.58126
Welt USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MR
MiTek'
6904 Parke East Blvd.
Tampa, FL 36510
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924388
506926
E5
Jack -Open
1
1
Job Reference (optional)
Tibbetts Lumber Co, Palm Bay, FL
Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:27 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfms,Ey71ZM-CSDAvnvPFmHYQiakhvlVEFYpoABgEipgseVComzzM76
1.6.0
1�-6�
5.00 12
Scale = 1:22.2
2x4 II 3 PROVIDE ANCHORAGE, DESIGNED BY OTHERS,
AT BEARINGS TO RESIST MAX.
2x4 tt
UPLIFT
AND MAX HORZ. REACTIONS
SPECIFIED BELOW.
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.30
Vert(LL) -0.00 4 n/r 120
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.05
Vert(CT) -0.01 4 n/r 120
BCLL 0.0
Rep Stress Incr YES
WB 0.02
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 16 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-6-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x6 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
1-4: 2x4 SP No.2
REACTIONS. (Ib/size) 2=93/Mechanical, 3=0/Mechanical
Max Horz 2=18(LC 18). 3=18(LC 12)
Max Uplift 2=-90(LC 12)
Max Grav 2=93(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=oft Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
t%1111111111�
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 90 lb uplift at joint 2.
� \p J O,R�
No 58126
: � • F 41J
it
Philip J. O.Regan PE No.58126
Mlrek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,&WARNING - Verily design parametersand READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE M11-7473 rev. 1010=015 BEFORE USE
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not,•
a truss system. Before use, the building designer must verifythe applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
prevent
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge courtyard
T15924389
506926
EJ1
Jack -Closed
29
1
Job Reference (optional)
Tibbetts Lumber Co, Palm Bay. FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:28 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy7lZM-genY77wl04PP2s9wEcpkmT4swaS1z8wg51FIKCzzM?5
4-0-0 9-0-0
' 4-0-0 5-0-0
3
NOP2XSTP =
2x4 11
Scale = 1:25.4
2-0-0 2,3-1$ 4-M
9-0.0
2-0-0 0-3-1 1-8 3
5-0-0
Plate Offsets (X,Y)— [1:0-0-2,Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl Lid
PLATES, GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.79
Vert(LL) -0.06
4-5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.14
4-5 >571 240
BCLL 0.0
Rep Stress Incr YES
WB 0.09
Horz(CT) 0.06
3 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Wind(LL) 0.09
4-5 >858 240
Weight: 32 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 54-11 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 cc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=152/Mechanical, 4=63/Mechanical, 6=446/0-7-10
Max Horz 6=200(LC 12)
Max Uplift 3=-149(LC 12), 6=248(LC 12)
Max Grav 3=161(LC 17), 4=109(LC 3), 6=446(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-6=382/512, 2-5=145/284
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-11-4 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by�2-0-0 widewill fit
to tween the ord other
forotruss toom
Vu snd.any
5) Refer connections.members.
\P , , 0.....
girder(s)
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 149 lb uplift atjoint 3 and 248 lb uplift at
6.
`,,��
�%% ��\ :�' G E N •' �'� ��j
Q : •�,\ S�`••. 2
joint
��
No 58126
�0 OF
ON
Philip J. O'Regan PE No.58126
MRek USA, Inc. FL Cert 6634.
6904 Parke fast Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERENCE PAGE IWI-7473 rev. 10M7/2015 BEFORE USE
'
Design valid for use ontywith M7ek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chard members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPl1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
T15924390
506926
EJ2
Jack -Open
�Qty
2
1
Job Reference (optional)
tooetts Lumber co, Palm tray, FL
Run: 8.240 s Dee 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:29 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-grLwKTwfnNXFfOk7oKLzJgdCfzrUibfzKy_ltezzM?4
3-6-0
3x6 11 6 NOP2X STP =
Scale = 1:11.7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) 1/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.09
Vert(LL)
0.00
6 >999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.16
Vert(CT)
0.00
6 >999
240
BCLL 0.0
Rep Stress ]nor
YES
WB 0.12
Horz(CT)
0.00
3 n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Wind(LL)
-0.00
5 >999
240
Weight: 15 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2
WEDGE
Left: 2x4 SP SS
REACTIONS. (lb/size) 3=9/Mechanical, 4=145/Mechanical, 6=390/0-7-10
Max Horz 6=77(LC 12)
Max Uplift 3=-14(LC 9), 4=-145(LC 1), 6=306(1-C 12)
Max Grav 3=16(LC 17), 4=111(LC 12), 6=390(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-416/189
BOT CHORD 1-6=154/433, 5-6=154/288
WEBS 2-6=347/702, 2-5=433/231
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-6-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0.0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; e6ve=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0.0 to 3-0-0, Interior(1) 3-0-0 to 3-5-4 zone; cantilever left and
right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3, 145 lb uplift at joint 4
and 306 lb uplift at joint 6.
\P �J.iorR����,,
�.
`Q�\• •� C E N S' �92 �i
No 58126
•
OF •:��C/�
Philip J. O'Regan PE No.58126
Mtrek USA, Inc. FL Cert 6634
699 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,& WARNING • Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M I.7473 rev. 10/0=015 BEFORE USE
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, note,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rFI1 Quality Criteria, DSO-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T16924391
506926
EJ3
Jack -Open
1
1
Job Reference (optional)
ibbetts Lumber Co, Palm Bay, FL
3x6 11
Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:30 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-d1uJXoxHYhf6H9JJM1sCruAJiNBAR127YcksP5zzM73
54-15
5-4-15
Scale = 1:15.3
2-1-13 2 515 ,
2-1-13 0L-2
45-15
2-0-0
5-0-15
0-11-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.32
Vert(LL) -0.02
5-6 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(CT) 0.00
5 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.18
Horz(CT) 0.01
3 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 21 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-4-15 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=57/Mechanical, 4=32/Mechanical, 6=371/0-8-4
Max Horz 6=11 O(LC 12)
Max Uplift 3=-55(LC 12), 4=-32(LC 1), 6=264(1_13 12)
Max Grav 3=59(LC 17), 4=45(LC 12), 6=371(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=751/202
BOT CHORD 1-6=158/739, 5-6=158/438
WEBS 2-6=327/1010, 2-5=-489/176
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-0-0 to 4-2-15, Exterior(2) 4-2-15 to 5-4-3 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by'2-0-0 wide
will fit between the bottom chord and any other members.
,%%J1111111811,
4) Refer to for truss to truss
\ F�
girder(s) connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift atjoint 3, 32 Ito uplift at joint 4
264 Ito 6.
! ♦,
�` •rN\ ':�' G E N
�\ tS'�•../!j
and uplift at joint
No 58126
� r
� r
r �
��SS,O
N AL ���``•
�nnll
Philip J. O'Regan PE No.58126
MITek USA,' Inc, FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
,,WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED 64TEK REFERENCE PAGE MI.7473 rev. 10/03,2015 BEFORE USE
'
Design valid for use only with Mrrek® connectors. This design is based only upon parameters shown, and Is far an Individual building component, not
e trUss-system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quality Criteda, DSB-99 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Ply
Ridge courtyard
T15924392
TGoobpher
506926
EJ4
Jack -Open
�Qty
1
Reference (optional)
Wells Lumber co, F91m Bay, FL
6
3x6 11
Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:30 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-dl uJXoxHYhf6H9JJM1 sCruAKiN9gR147YcksP5zzM73
4
I�
0
Scale = 1:14.7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.26
Vert(LL)
0.00
5
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.28
Vert(CT)
0.00
5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.18
Horz(CT)
0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
-0.01
5-6
>999
240
Weight: 20lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=49/Mechanical, 4= 47/Mechanical, 6=369/0-8-4
Max Horz 6=103(LC 12)
Max Uplift 3=-47(LC 12), 4=-47(LC 1), 6=269(1_C 12)
Max Grav 3=51(LC 17), 4=53(LC 12), 6=369(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=771/206
BOT CHORD 1-6=164/765, 5-6=164/476
WEBS 2-6=316/1001, 2-5=532/184
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-0-0 to 4-2-15, Exterior(2) 4-2-15 to 5-0-2 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by'2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 3, 47 lb uplift at joint 4
and 269 lb uplift at joint 6.
,&WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI.7473 rev. 1010312015 BEFORE USE
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabdcallon, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
�11111111//�
,V�Q J. O'qF
No 58126
� r
ST F :,�/�
O; N
nnl
Philip J. O'Regan PE No.58126
MRek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
Well(
6904 Parke East Blvd.
Tampa,. FL 36610
Job
Truss
Truss Type
Ply
Gopher Ridge Courtyard
�Qty
T15924393
506926
EJ5
Jack -Open
3
1
Job Reference (optional)
IDeeaa Lumber co, Falm Bay. FL Run: 8.240 s Dec 6 2018 Print: 8:240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:31 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-5DShl8ywl?nzvJtVwINR05ixOnXZAVnGnGTPxXzzM?2
5-0-0
5-M 1
Scale = 1:16.4
NOP2X STP =
2x4 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc) I/deft
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.14
Vert(LL)
0.00
5-6 >999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(CT)
0.00
5-6 >999
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.08
Horz(CT)
0.00
3 n/a
n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix -MP
Weight: 20 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=54/Mechanical, 4=33/Mechanical, 6=344/0-7-10
Max Horz 6=11O(LC 12)
Max Uplift 3=-55(LC 12), 4=-62(LC 20), 6=289(1_10 12)
Max Grav 3=57(LC 17), 4=3(LC 3), 6=344(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=376/174
BOT CHORD 1-6=133/389
WEBS 2-6=277/475
BRACING-
TOP CHORD
'
Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
i
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-11-4 zone; cantilever left
and right exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 3, 62 lb uplift at joint 4
and 289 lb uplift at joint 6.
,& WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED mr EK REFERENCE PAGE MII-7473 rev. 1010=15 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not'',
a truss system. Before use, the building designer must verify the applicability of design parameters and pro pedy Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIoTP/f Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
1111/11111/II�
O'qF ,'.i0i
♦ V F • `o
No 89126
ss'O N A' 00,C? �.
Philip J. VRegan PE No.58126
MiTek USA, Inc. FL Cert 6634.
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924394
506926
Hit
Diagonal Hip Girder
6
1
Job Reference (optional)
i ..,, ro„„ oa .24u s Uec 16 2u19 MITeK industries, Inc. Wed Jan 2 16:29:32 2019 Pagel
ID;zNgPoPtcZMR2GpwObQfmsEy71 ZM-ZQ03yUzY3lvq WfSiTSugxJ Fb2BmwvwfpcwDzTzzzM?1
3-2-0 8-0-0 12-8-0 Scale = 1:22.2
3-2-0 4-10-0 4-8-0
JX9 --
2X4 II
2.8-10 3 2-0 8-0-0
12-8-0
2 8 10 0-5-7 4-10-0
4.8-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL) 0.08
7-8 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) 0.07
7-8 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.23
Horz(CT) -0.01
4 I n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 57 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 4=120/Mechanical, 5=157/Mechanical, 8=273/0-10-13
Max Horz 8=199(LC 24)
Max Uplift 4=-112(LC 8), 5=-141(LC 5), 8=594(LC 8)
Max Grav 4=120(LC 1), 5=286(LC 28), 8=762(LC 31)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=516/602, 2-12=679/354, 12-13=-582/303, 3-13=-519/283
BOT CHORD 1-8=564/524, 8-15=564/325, 15-16=-564/325, 7-16=-564/325, 7-17=-333/469,
6-17=333/469
WEBS 2-8=565/372, 2-7=342/610, 3-6=-535/379
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. '
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
,`�11111111��
will fit between the bottom chord and any other members.
4) Refer to for truss to truss
\Q �'
girder(s) connections.
5 bProvide mchanical
594eion b others of truss to beariri capable able of withstanding112 lb uplift at joint 4, 141 lb uplift at joint
b g
%��
NV
E N �� �00,
and uplift at joint
��,,Q���
,�
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 167 lb down and 215 lb up at
No 58126
4-2-15, 167 lb down and 215 lb up at 4-2-15, 97 lb down and 64 lb up at 7-0-14, 97 lb down and 64 lb up at 7-0-14, and 127lb down
and 122 lb up at 9-10-13, and 127 lb down and 122 lb up at 9-10-13 on top chord, and 119 lb down and 187 lb up at 42-15, 119 lb
* ,• ;
down and 187 lb up at 4-2-15, 20 lb down and 58 lb up at 7-0-14, 20 lb down and 58 lb up at 7-0-14, and 36 lb down at 9-10-13,
and 36 lb down at 9-10-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
-p ;
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
.� F [V
LOADCASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
��OT,[��.� ,
�� ` •; (3 •' N �%
Uniform
%%
,���s`S�� N A� ���
Vert 1(4I�54, 5 9=-zo
Concentrated Loads (lb)
111
Vert: 12=168(F=84, B=84) 14=49(F=24, B=24) 15=202(F=101, B=101) 16=62(F=31, B=31) 17=0(F=-0, B=-0)
Philip J. O'Regan PE No.58126
MITek USA, Inc.'FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED mTEK REFERENCE PAGE mr-7473 rev. 10/032015 BEFORE USE
M
Design valid for use only with 7ek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not!
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the I
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTF11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924395
506926
HJ2
Diagonal Hip Girder
1
1
Job Reference (optional)
I Means Lumber Co, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:32 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-ZQ03yUzY31vgWTSiTSugxJFc3BntvyXPOwDzTzzzM?1
3-9-9 7-0-2
3-9-9 3-2-8
Scale = 1:15.2
m
6
2x4 11
2-8-14 3 1-2
7-0-2
2-8-14 O-4 4
3-11-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
1
(loc) Wen Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.53
Vert(LL) -0.05
5-6 >881 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.50
Vert(CT) 0.05
5-6 >950 240
BCLL 0.0
Rep Stress Incr NO
WB 0.11
Horz(CT) -0.01
3 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 28 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=49/Mechanical, 4=95/Mechanical, 6=237/0-8-8
Max Harz 6=11 O(LC 24)
Max Uplift 3=-75(LC 8), 4=-161(LC 17), 6=-468(LC 8)
Max Grav 3=87(LC 28). 4=146(LC 24), 6=506(LC 31)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=443/525
BOT CHORD 1-6=490/451, 6-11=490/341, 5-11=-490/341
WEBS 2-6=349/269, 2-5=352/506
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=�1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
for
/1111111/ rrr�j,
4) Refer to girder(s) truss to truss connections.
75 lb 3, 161 lb 4
J 0r
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding uplift at joint uplift at joint
lb 6.
%%
% ���'� E ••' �'9 ��i
and 468 uplift at joint
load(s) 145 lb down 190 lb up at
��G
Q '•�,\ SF•'.? �i�
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated and
`��
4-2-15, and 145 lb down and 190 lb up at 4-2-15 on top chord, and 85 lb down and 161 lb up at 4-2-15, and 85 lb down and 161 lb
N O 58126
up at 4-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
"0
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
13 S F 41J
Q•
Vert: 1-3=-54, 4-7=-20
Concentrated
���T'•�� QQ;� ���
Vert: 10a147(F=73, B=73) 11=176(F=88, B=88)
��iis�ONA1.� %%
rune
Philip J. O'Regan PE No.58126
Mffek USA, Inc. FL Cert 6634
6904 Parkafast Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M TEK REFERENCE PAGE MI-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an. individual building component, notl
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 216 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924396
506926
HJ3
Diagonal Hip Girder
1
1
Job Reference (optional)
Ibbetts Lumber Cc, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:33 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfnisEy71 ZMA caRAgzAgc2h8dl u19PvTWnnpb76ePnZFZyV4OPzzM7D
-0 Q,12 3-9-9 7-0-2
0 - 2 3-9-9 3-2-8
Scale = 1:15.2
2x4 11
2-8-14
0-"
! 3-11-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.53
Vert(LL) -0.05
5-6' >881 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.50
Vert(CT) 0.05
5-6; >950 240
BCLL 0.0
Rep Stress Incr
NO
WB 0.11
Horz(CT) -0.01
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 28 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 6-0-0 cc bracing.
WEBS 2x4 SP No.2
REACTIONS. (lb/size) 3=49/Mechanical, 4=95/Mechanical, 6=237/0-8-8
Max Horz 6=11 O(LC 8)
Max Uplift 3=-75(LC 8), 4=-161(LC 17), 6=468(LC 8)
Max Grav 3=87(LC 28), 4=146(LC 24), 6=506(LC 31)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-443/525
BOT CHORD 1-6=490/451, 6-11=490/341, 5-11=-490/341
WEBS 2-6=349/269, 2-5=352/506
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL 41.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by'2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 75 lb uplift at joint 3, 161 lb uplift at joint 4
and 468 lb uplift at joint 6.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 145 lb down and 190 lb up at
4-2-15, and 145 lb down and 190 lb up at 4-2-15 on top chord, and 85 lb down and 161 lb up at 4-2-15, and 85 lb down and 161 lb
up at 4-2-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 4-7=-20
Concentrated Loads (lb)
Vert: 10=147(F=73, B=73) 11=176(F=88, B=88)
I
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mg-7473 rev. 1010=015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not/
a truss system. Before use, the building designer must verify the applicability of design parameters and properlyincorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/1 Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
J.
O�A�,',',
♦ NV
No 58126
OF �/�
.�,,\•,.o•0R`OP \�♦�.
ON A
11111
.Philip J. O'Regan PE No.58126
MITek USP, Inc. FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MF
MiTek'
6904 Parke East Blvd.
Tampa,FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924397
506926
V1
Valley
1
Job Reference (optional)
1 IDDetts Lumber Go, Palm Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dee 18 2018 MiTek Industries, Inc. Wed Jan 2 16:29:33 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-1 caRAgzAgc2hBdl ul gPvTWntnbCmePJZFZyWDPzzM7D
14-M 155-0
14-" 0-10-8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD
2x4 SP No.2
BOT CHORD
2x4 SP No.2
WEBS
2x4 SP No.2
OTHERS
2x4 SP No.2
3x4
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
1/defl
L/d
Plate Grip DOL 1.25
TC 0.14
Vert(LL)
n/a
n/a
999
Lumber DOL 1.25
BC 0.14
Vert(CT)
n/a
n/a
999
.Rep Stress Incr YES
WB 0.08
Horz(CT)
0.00 7
n/a
n/a
Code FBC2017/rP12014
Matrix-S
3x4 = Scale = 1:34.8
5 6
PLATES GRIP
MT20 244/190
Weight: 66 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 15-5-0.
(lb) - Max Horz 1=292(LC 12)
Max Uplift All uplift 100lb or less atjoint(s) 7 except 9=173(LC 12), 10=165(LC 12), 8=-166(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 9=299(LC 21). 10=293(LC 17), 8=367(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=324/159
WEBS 2-1O=211/267, 4-8=222/289
NOTES-
1) Unbalanced roof live loads have been Considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (&second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; e6ve=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-9-1 to 3-8-8, Interior(1) 3-8-8 to 14-6-8, Exterior,(2) 14-6-8 to
15-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are 2x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb)
9=173, 10=165, 8=166.
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED N9TEK REFERENCE PAGE MI.7473 rev. 10MI2015 BEFORE USE -
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Seto re use, the building design or must verify the applicability of design parameters and propedy incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSMI1 Quality Criteria, DS8-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
�1111111/f��
E N
No 58126
13 : OF �;��Z
-Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
W1,
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610.
Job
Truss
Truss Type
Qty,
Ply i
Gopher Ridge Courtyard
5013926
V2
Valley
1
t
T75924398
Job Reference (optional)
Ibbetts Lumber Co, Palm Bay, FL
4
0
3x4 � 10
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL 20.0
Plate Grip DOL
1.25
TC 0.16
TCDL 7.0
Lumber DOL
1.25
BC 0.12
BCLL 0.0
Rep Stress Incr
YES
WB 0.06
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
LUMBER.
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2
OTHERS 2x4 Slb No.2
Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:34 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71ZM-Vo8pNA obwAYrnnc4btw80kK2E_ZLNtviTDi3YszzM??
12-6-8 13-5.0
12-M 0-10-8
3x4 = Scale = 1:30.3
5 6
13-5-0
DEFL. in (loc) i Vdefl L/d PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(CT) n/a n/a 999
Horz(CT) 0.00 7 n/a n/a
Weight: 57 lb FT = 20%
BRACING -
TOP CHORD Structural'wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 13-5-0.
(lb) - Max Horz 1=248(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 9=181(LC 12), 10=-144(LC 12). 8=-144(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 9=315(LC 17), 10=256(LC 17), 8=307(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=299/149
WEBS 2-10=187/268, 4-8=193/283
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuk=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 12-6-8, Exterior(2) 12-6-8 to
13-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are 2x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf. j
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except fit=lb)
9=181,10=144,8=144.
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERENCE PAGE M11.7473 rev. 1"3/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not!
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the !
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSS-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. . i
11111111111�
%` �P J. O'qF�,�
E Ns
No 58126
01�s`S�O N A� E���`•
In
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MITek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T15924399
506926
V3
Valley
i
1
Job Reference (optional)
Co, raim Bay, FL Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:35 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-z7iCbWtQMDIPNxBH9aSNYxtB4OuS6K5sitRd4lzzM7_
10-" 11-5 0
10-6-8 010 B
v
4
0
3x4 =
Scale = 1:26.6
2x4 II
2x4 11 4 5
3x4 � 8 7 62x4 II
LOADING (psi)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/rP12014
2x4 11 2x4 11
11-5-0
CSI.
DEFL.
in (loc) Udefl
Ud
TC 0.28
Vert(LL)
n/a n/a
999
BC 0.19
Vert(CT)
n/a n/a
999
WB 0.06
Horz(CT)
-0.00 6 n/a
n/a
Matrix-S
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 BOT CHORD
OTHERS 2x4 SP No.2
REACTIONS. All bearings 11-5-0.
(lb) - Max Horz 1=203(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 6 except 8=232(1_C 12), 7=107(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 6, 7 except 8=410(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-8=293/355, 3-7=151/267
PLATES GRIP
MT20 244/190
Weight: 47 lb FT = 20%
Structuial wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-0.0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9.1 to 3-9-1, Interior(1) 3-9-1 to 10-6-8, Exterior(2) 10-6-8 to
11-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb)
8=232, 7=107.
,A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M TEK REFERENCE PAGE AVI-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
��II11111111��
,��•��Q J. O'qF
No 58126
S F
Ak-���`
�111nn11
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTeW
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
T75924400
506926
V4
Valley
1
1
Job Reference (optional)
Tibbetts Lumber Co, Palm Bay, FL
Run: 8.240 s Dec 6 2018 Print: 8240 s Dec 18 2018 MIT Industries, Inc. Wed Jan 2 16:29:35 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-z7iCbWlQMDIPNxBH9aSNYxtCPOuM6K8sitRd4lzzM7_
95-0
0-10-8
4x6 II Scale= 1:22.7
2x4 11
3 4 5
8 7 6
2x4 :7- 2x4 II 2x4 II 2x4 II
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.20
TCDL
7.0
Lumber DOL
1.25
BC 0.13
BCLL
0.0 '
Rep Stress ]nor
YES
WB 0.06
BCDL
10.0
Code FBC2017/TPI2014
Matrix-S
9-5-0
9-5-0
DEFL. in (loc) Vdefl Ud PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(CT) Tile n/a 999
Horz(CT) -0.00 6 n/a n/a
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 BOT CHORD
OTHERS 2x4 SP No.2
REACTIONS. All bearings 9-5-0.
(lb) - Max Horz 1=158(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) 6, 7 except 8=203(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 6, 7 except 8=354(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-8=257/335, 4-7=163/299
Weight: 39 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 8-6-8, Exterior(2) 8-6-8 to
9-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7 except (jt=lb)
8=203.
,&WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE AVI.7473 rev. 10/03,2018 BEFORE USE
Design valid for use only with Mrrek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a trusssystem. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
`,111111111/J. Or 4
. •404*
.,
0i
No 58126
Philip J. O'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Gopher Ridge Courtyard
15924401 T
506926
V5
Valley
1
1
Job Reference (optional)
Marla Lumber Co, Palm Bay, FL
v
O
O
Run: 8.240 s Dec 6 2018 Print: 8.240 s Dec 18 2018 MITek Industries, Inc. Wed Jan 2 16:29:36 2019 Page 1
ID:zNgPoPtcZMR2GpwObQfmsEy71 ZM-RBGaos027XQG?4mTllzc59POzoF4mS?xXBACkzzM_Z
6-6-8 7-"
0-10-8
3x4 =
2x4 II
6 5
2x4 7.'-' 2x4 II 2x4 II
Scale = 1:18.2
7-5-0
7-5-0
Plate Offsets (X,Y)— [3:0-2-0,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.15
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.10
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WE 0.06
Horz(CT) -0.00
5 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 26 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2
end verticals.
WEBS 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.2
REACTIONS. (lb/size) 1=88/7-5-0, 5=11517-5-0, 6=279/7-5-0
Max Horz 1=114(LC 12)
Max Uplift 1=6(LC 12), 5=-57(LC 12), 6=154(LC 12)
Max Grav 1=88(LC 1). 5=115(LC 1), 6=284(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-6=205/316
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=2411; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-8-8, Interior(1) 3-8-8 to 6-6-8, Exterior(2) 6-6-8 to
7-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This has been designed for 10.0 bottom live load live loads.
`,111111111++��
, I�
.%%! \Q J' AF ��j
truss a psf chord nonconcurrent with any other
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
%
�S' �,9 ..00
�� �N :•' G E
fit between the bottom
N
Q : • V� F�'.? 40�i
will chord and any other members.
��,
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
No 58126
6=154.
_•
•
•
G
++111111111
Philip J. Q'Regan PE No.58126
MITek USA, Inc. FL Cert 6634
69M Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M117TEK REFERENCE PAGE MI.7473 rev. 1010312015 BEFORE USE
Design valid for use only with WWI) connectors. This design Is based only upon parameters shown, and is for an individual building component, not I
�1•
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI?PH Quality, Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36010
Job
Truss
Truss Type
Qty,
Ply
Gopher Ridge Courtyard
T15924402
506926
V6
Valley
1
Job Reference (optional)
iooems Lumoer c0, Palm Way. rL
2x4
2x4 11
tiun: u.z4u s uec b zut6 Print: B.Z4u s uec 16 Zut6 MI7 ex iroustnes, Inc. Wea Jan 2 16:Z9:36 2u19 Pagel
ID:zNgPoPtcZMR2GpwObQ.fmsEy71ZM-RBGaosO27XQG?4mTilzc59PPvoGtmZ?xXBAckzzM—z
5-5-0
0-10-8
5-5-0
3x4 =
2x4 II
Scale = 1:13.7
Plate Offsets (X,Y)—
[3:0-2-0,Edge]
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.09
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.05
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.05
Horz(CT) -0.00 5 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix-S
Weight: 18 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.2 BOT CHORD
OTHERS 2x4 SP No.2
REACTIONS. (lb/size) 1=60/5-5-0, 5=85/5.5-0, 6=189/5-5-0
Max Horz 1=69(LC 12)
Max Uplift 1=-8(LC 12), 5=41(LC 12). 6=101(LC 12)
Max Grav 1=60(LC 1), 5=85(LC 1), 6=192(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-6=145/274
Structural wood sheathing directly applied or 5-5-0 oc purling, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-6-8, Exterior(2) 4-6-8 to
5-3-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
6=101.
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED AI TEK REFERENCE PAGE M11-7473 rev. 1010312016 BEFORE USE.
Design valid far use only with MTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overell
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11 P/1 Quality Criteria, DSB.89 and BCSI Building Component
Satefyinformation available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
/1111111/►II
No 58126
:irZ
F : 41J�
A� E?C�,.
1
Philip J. O'Regan PE No.58126
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
January 3,2019
M!Tek'
6904 Parke East Blvd.
Tampa, FL 36610
Symbols
Numbering System
General Safety Notes
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
4 offsets are indicated.
64-8 dimensions shown In ft-in-sixteenths
(Drawings not to scale)
Failure to Follow Could Cause Property
Damage or Personal Injury
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
1 2 3
1. Additional stability bracing for truss system, e.g.
and fully embed teeth.
TOP CHORDS
diagonal or X-bracing, is always required. See BCSI.
D�y16��
—C� 2 — —•-- �=3 —
2. Truss bracing must be designed by an engineer. For
T
I
WEBS 4
y
� p
O _ 1
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor 1
bracing should be considered.
O
3. Never exceed the design loading shown and never
d U
stack materials on inadequately braced trusses.
o'er cs� cs s 0
4. Provide copies of this truss design to the building
For 4 x 2 orientation, locate
plates 0- tiis' from outside
F—
BOTTOM CHORDS
designer, erection supervisor, property owner and
all other interested parties.
edge of truss.
8 7 6 5
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
..«.. This symbol indicates the
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
joint and embed fully. Knots and wane at joint
required direction of slots in
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
locations are regulated by ANSI/TPI 1.
connector plates.
THE LEFT.
7. Design assumes trusses will be suitably protected from
Plate location details available In MITek 20/20
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
the environment in accord with ANSI/TP1 1.
software or upon request.
NUMBERS/LETTERS.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
PLATE SIZE
PRODUCT CODE APPROVALS
9. Unless expressly noted, this design is not applicable for
ICC-ES Reports:
use with fire retardant, preservative treated, or green lumber.
The first dimension is the plate
10. Camber is a non-structural consideration and is the
4 x 4 width measured perpendicular
ESR-1311, ESR-1352, ESR1988
responsibility of truss fabricator. General practice is to
to slots. Second dimension is
ER-3907, ESR-2362, ESR-1397, ESR-3282
camber for dead load deflection.
the length parallel to slots.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
LATERAL BRACING LOCATION
12. Lumber used shall be of the species and size, and
Indicated by symbol shown and/or
>_ --by-text in -the bracing section -of the—
Trusses are designed for wind loads in the plane of the
truss -unless otherwise -shown.— - -
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or puffins provided at
output. Use T or I bracing
spacing indicated on design.
if indicated.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
g y
14. Bottom chords require lateral bracing at h r spacing,
or less, if no ceiling is installed, unless otherwise noted.
BEARING
established by others.
15. Connections not shown are the responsibility of others.
Indicates location where bearings
(supports) occur. Icons vary but
16. Do not cut or alter truss member or plate without prior
© 2012 MiTekB All Rights Reserved
approval of an engineer.
reaction section indicates joint
number where bearings occur.
17. Install and load vertically unless indicated otherwise.
Min size shown is for crushing only.
__
18. Use of green or treated.lumber may pose unacceptable
environmental, health or performance risks. Consult with
Industry Standards:
W1
project engineer before use.
ANSI/TPI1: National Design Specification for Metal
19. Review all portions of this design (front, back, words
.Plate Connected Wood Truss Construction.
and pictures) before use. Reviewing pictures alone
DSB-89: Design Standard for Bracing.
®
is not sufficient.
BCSI: Building Component Safety Information,
M!Tek
20. Design assumes manufacture in accordance with
Guide to Good Practice for Handling,
ANSI/rPI 1 Quality Criteria.
Installing & Bracing of Metal Plate
Connected Wood Trusses.
MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015