HomeMy WebLinkAboutEnergy Codeeu
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
. Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 33 Block 2 Waterstone 2265 AGL
Builder Name: ADAMS HOMES
Street: 8501 Waterstone Boulevard
Permit Office:
City, State, Zip: Port Saint Lucie, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1994.2 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ft2
b. Frame - Wood, Exterior
R=13.0 407.83 ftz
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5. Is this a worst case? No
11. Ceiling Types (2357.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2277.00 ftz
6. Conditioned floor area above grade (ftz) 2277
b. Knee Wall (Vented)
R=19.0 80.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(273.9 sqft.) Description Area
12. Ducts
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
a. U-Factor: Dbl, U=0.33 154.00 ftz
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 66.00 ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 35.56 ftz
0
SHGC: SHang
Area Weighted Average Overhang Depth: 5.043 ft.
.
14Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.292
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2277.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
Pstat
Glass/Floor Area: 0.120 Total Proposed Modified Loads: 63.69
PASS
Total Baseline Loads: 66.97
I hereby certify that the plans fications covered.Jay�^"'°
Rev w of the plans and
,O�� E ST.gp
this calculation are in comp n e Flo ' nergy
specifications covered by this
.
Code.
calculation indicates compliance
with the Florida Energy Code.'
PREPARED BY:
Before construction is completed
O
DATE: 02-04-9021 Winn KPnman y
this building will be inspected for
9 P
compliance with Section 553.908
t9. .` --
,�,; e'•`
I herebycertify that this building, as designed, is in compliance
fY 9, 9 P
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT -
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.1.2).
4
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 33 Block 2 Waterstone 22 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 33-2
Block/Subdivision: Waterstone
PlatBook:
Street: 8501 Waterstone Boule
County: St. Lucie
City, State, Zip: Port Saint Lucie ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft2 ---- 0.35 0 0.65
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ft2 570 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown 2277 ft2 0.11 Wood
Main 19 Double Batt 80 ft2 0.11 Wood
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar Below
Space
1 NE
Exterior
Frame - Wood
Main
13
10
2
8
0
81.3 ft2
0
0.23 0.6
0
2 NE
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10
0
385.8 ft2
0
0 0.6
0
3 NW
Exterior
Frame - Wood
Main
13
4
6
10
0
45.0 ft2
0
0.23 0.6
0
4 NW
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10
0
285.0 ft2
0
0 0.6
0
5 SW
Exterior
Frame - Wood
Main
13
6
9
8
0
54.0 ft2
0
0.23 0.6
0
6 SW
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8
0
402.0 ft2
0
0 0.6
0
7 S
Exterior
Frame - Wood
Main
13
3
10
10
0
38.3 ft2
0
0.23 0.6
0
8 S
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10
0
4.2 ft2
0
0 0.6
0
9 SE
Exterior
Frame - Wood
Main
13
18
11
10
0
189.2 ft2
0
0.23 0.6
0
10 SE
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8
0
301.3 ft2
0
0 0.6
0
11 -
Garage
Frame - Wood
Main
13
26
0
8
0
208.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated
Main
None
.25
3
6 8
20 ft2
2
Wood
Main
None
.25
2
8
6 8
17.8 ft2
3
SW
Insulated
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
NE 2
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
NW 3
Vinyl Low-E Double
Yes
0.33
0.31
N
5.0 ft2
7 ft 8 in
0 ft 6 in
None
None
4
NW 4
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
NW 4
Vinyl Low-E Double
Yes
0.33
0.21
N
30.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
NW 4
Vinyl Low-E Double
Yes
0.33
0.21
N
36.0 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
SW 6
Vinyl Low-E Double
Yes
0.33
0.23
N
9.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
SW 6
Vinyl Low-E Double
Yes
0.33
0.23
N
15.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
S 7
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
SE 9
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
SE 9
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
SE 9
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
SE 10
Vinyl Low-E Double
Yes
0.33
0.23
N
45.0 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617ft2
617ft2
64ft 9ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ftZ
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingH Jan
HeatinJan
Feb
Feb
H
Mar
Mar
HX
A r
APr
[
[
] Ma
]May
X Jun
Jun
i
Jul
Jul
rj
AuSeP
rj Aug
Se
ri
[ ] Oct
[ ]Oct
Nov
Nov
Dec
Dec
Ventin Jan
Feb
Mar
[
Apr
[
] May
Jun
Jul
Aug
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
8501 Waterstone Boulevard, Port Saint Lucie, FL, 34951
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.70
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Exterior
1
c. Frame - Wood, Adjacent
4
d. N/A
11. Ceiling Type and insulation level
No
a. Under Attic (Vented)
2277
b. Knee Wall (Vented)
Area
c. N/A
154.00 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
66.00 ft2
13. Cooling systems
35.56 ft2
a. Central Unit
18.33 ft2
5.043 ft.
0.292
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
Insulation
Area
R=4.1
1378.30 ft2
R=13.0
407.83 ft2
R=13.0
208.00 ft2
R=
ft2
Insulation
Area
R=30.0
2277.00 ft2
R=19.0
80.00 ft2
R=
ft2
R ft2
6 456.2
kBtu/hr
Efficiency
35.0 SEER:16.00
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/4/2021 3:26 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1