HomeMy WebLinkAboutBuilding Plans.pdfSTRAPPING SCHEDULE
Additional
45 bare
•;;,;�}';; i COVER
Precast Lintel
8F8-OBAT
Additional
C R ... .. u5 bare
COVER
jr• ,
One Row of Beam
-•;:• Block Above
BFIL-BAT BFIL-I15/2T
NOTES:
I. MIN, COVERAGE OF STEEL = 1.5"
2. MIN. BEARING REQUIRED ® EA. END = 4"
S. STANDARD FOR R£INF. STEEL = ASTM A415 GRADE
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
Lintel
Length
Bar
Length
Clear
Span
I "A"
113ars
"B"
Bars
2'-10"
2'-8"
-6"
2,#3
none
3'-6"
3'-4"
2'-2"
2,43
none
4'-0"
3'-10"
2'-8"
2,43
none
4'-6"
4'-4"
3'-2"
2,93
none
51-4"
5'-2"
4'-0"
2,43
none
5'-8"
-4'- 6
1 2,44
none
6'-4"
5'-4"
2,#4
none
T-0"
6'-2"
2,99
none
1'-10"
1'-0"
2,#5
none
ALL reinforcing steel is grade 60
LINTEL SCHEDULE
Window
P fe_
Rows of
Max
Max.
Max.
Mark
DomStressed
Uni
Lintel
Cast -Crete
BMBlock
Bottom
Top
Load ity
Looafd
Lateral
o ai
Width
Size
S ecification
Steel
Sire
Steel
size
(PLF)
(PLF)
(PLF)
L22
2 _2•
2'-10'
8F8-OD/IT
NO
—
1
#5
30L9
IBL9
IL42
L31
T-L'
3'-9'
8F8-OBAT
NO
—
I
#S
25LI
13L3
163
3,_l'
L45
4'-6'
I 6'-I"
8F8-OBAT
I NO
—
I
1 #5
1 1349
1 1016
411
L60
5'-O'
S'-8'
8F8-OBAT
I NO
—
1
#6
1 1106
1 9041
1 339
LLO
L'-8'
L'-e"
81"8-OBAT
50
—
1
#6
1 1011
1 92-1
1 534
LSO
T'-O'
-'-O"
or8-OBAT
I NO
—
1
#6
1 1011
1 127
1 534
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS
SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE
CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD
REQ.
REQUIREMENTS
- LINTELS
OVER
13'-11" LONG ARE TO BE PRESTRESSED.
- CONTRACTOR
TO VERIFY ALL LINTEL SIZES BASED ON FINAL
MASONRY
OPENING
SIZES AND ADJUST LINTELS ACCORDINGLY PRIOR TO ORDERING
ANY/ALL
LINTELS
ROOF: SHEETING
ATTACH>1ENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws bas d on pressure for roof stated
in permit info box on these plans for zone 3
Keu
Area
Ede
Field
Fastener
Pressure
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
4"
6"
8d ring shank
% psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
6"
6"
#8 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Prov
(a) 3,
of W
N
W
L60 BI
L31
Q
in
BI
per product approval FL# 111-T5.1
roofing underlagment over 19/32'
over PoIyglass self adhered
CDX plywood attached
6 SLOPE
Ln
SLOPE 6
',
W
24"
O.H.
AT 24"o.c.
YPICAL
—
SEE SECTION FOR BO
TOM CHORD SLOPE
====P
(8)
ovide Simpson
3/14" dia. x I
Wall and (10)
(V
�
B2 '1
II
24"
[Q IIII
O
11174
Q
III
II
H
= TT
SLOPE 3 III
_
M
L31 BI L31
LGO BI
IIII
24"
_N.
m IIII
�16" dia. x 1 34' Tapcons ino Fa
all and (10) IOd nails Into Beam
I I
B
—
o
N
cn
HT
B2
(o
at
B2
IIII
II
IIII
2
ROOF PLAN
HETA
SIMPSON HETA 20 hurricai
anchor at each truss supportir
Max. 1,810 lbs. uplift. Strap
have (9) IOd x 11/2" nails.
STRAPPING SCHEDULE
HTS 2
Simpson HTS 20 hurricane
anchor at each truss (24" o.c.)
supporting Max. 1,450 lbs.
uplift w/ (24) IOd x 1.5" nails
(2) 2" x 12" Wood Beam w/ 1/2" plywd
( see Roof Plan for location& )
1
HU212-2 (Max) with/ (2) 5/8° Dia Bolts
3/" Tapcons ino Face
IOd nails into Beam 31/6" x 31h" x 'A"t
6 1/4"W x 9 1/2"D x 9"H x 1/4"T Steel Column
column cap prewelded to steel column 16
w/ (2) predrilled 5/8" Die. holes
for 5/8" bolts bg manufacturer
COLUMN TO BEAM CONNECTION
I I NTS
TYPICAL ROOF NOTES: Scale 1/4" = 1'-0"
— Overhangs shall be 2'-0" unless otherwise noted on this sheet (2) 2" X 12" Wood Beam
— Roof pitch shall be L12 unless otherwise noted on this sheet w/ 1/2" plywood plate
— Truss shop drawings to be provided by manufacturer
— Any changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
— ALL TRUSS TO TRUSS CONNECTIONS BY
L" x 6" PT Wood post
Simpson ABU 66 Post base
with 5/8" dia. A.B. embedded 8" min.
into concrete footing. Use (12) IGd
nails into post - OR - (2) 1/2" dia.
thrubolts.
110
9
a
LL -Q
v �
N
v
N
30 x 36" x 12" concrete footing v
3 with #5 bars at L" o.c. each way. n/
Min. side and bottom clearance to tK
steel shall be 3" all sides
DETAIL AT 6"x6" POST CONNECTION
Scale: 3/4" = 1`0"
- . UO
ro,
Two Rows of Beam Block filled
with concrete and one #5 bar
i continuous in each row
a
TRUSS MANUFACTURER Provide Simpson HU212-2 (Max) With
— Architect to review Truss Shop Drawings Prior (8) 3/16" dia, x 1 3/6" Tapcons ino Face I
to construction for layout and uplift verification of Wall and (10) IOd nails into Beam
— Contractor to provide for Form Board Survey and to provide Wood Beam to CBS Wall D & t a l l
Form Board Survey to Truss Company prior to truss construction
— Contractor to provide the Architect with truss shop drawings Including
ALL truss cut sheets showing ALL truss reactions prior to START
OF FOUNDATION WORK for Strap and footing size verification.
— TRUSS DEFLECTION SHALL NOT EXCEED 0.5" ON ANY TRUSS.
NTS
0
4J
(n
Q N
c =0
L > C�1
00
6Qinm m
c NN uU
q ' CjD OD EE Q
ONN R
L-
m
4-� r r u
oui LIJ
4'
sli
L
� 0 E LL.
W 41
�
41
N
rr1,
Sheet
Comm #
18-23�
Attach window to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 4" PT Buck
Exterior face
of wall --\
Detall at windows
Exterior face
Of wall —
I"x4" P.T. Buck
2 sides d header
NTS
Attach door to block wall with
1/4" dia. x 3" tap —cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 8" PT Buck
P.T. Buck
2 sides d header
Detail at Exterior Doors
NTS
Southeastern Metals 24 ga 5v Crimp Metal Roofing installed
per product approval FL# 11116.1 over Polyglass self adhered
roofing underlayment over 19/32" CDX plywood attached
to trusses per sheeting attachment diagram on roof plan
Simpson HETA 20 or
11dxat with10) 0l/2"
( 24" o.c.) supporting
1810lbs. uplift
Gaiv-Alum Metal drip on
I" x 4" Drip on
1" x 8" Fascia on
2" x 6" Sub -Fascia
James Hardie Products Hardi—Soffit FL# 13245.1 /
Install hardi soffit nailed to 2" x 4" soffit framing at max.
24" o.c. with 1.5" long x 0.083" shank dia. x 0.18-1" HD
ring shank nails at 8' o.c. field and edges IAW product
approval and manufacturers req.
5/8" thick light textured
stucco on typical concrete
block construction
#5 bar vert. w/
SO" overlap —
at each filled cell
12
6
M
6" min. of Icynene LD-C-50 spray foam insulation on
bottom of roof sheathing in compliance with ICC-ESR-182L
dated Feb. I, 2012. Install DC 315 Intumescent coating
per section 4.3.2 of [CC test noted above to comply
with 15 min. thermal barrier requirements.
PRE-ENGINEERED SCISSOR TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer )
5/8" drywall with smooth finish
1/2" drgwall over I" x furring
strips at 16" o.c. with R4.2 iyfoil
insulation on typical 8" Block walls
All drywall is per FBC 102.3.1 and
shall meet all pertaining ASTM codes.
Mortar to be Type "M" onlg
Provide Dur-O-Rock at all" wet
areas (ex. showers, tubs etc...)
o-
Fill cell with concrete and
(U 45 bar vert. (typical).
Max. spacing shall not exceed
32" unless otherwise noted
see foundation plan notes for
spacing at openings
V0aerd 4" concrete slab with fibermesh OR 6"x6 111:10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade
!I IIII—ill) 11�1�
�!il ,,llll����lllli111ll11��„IIII, I!''
16"w x i6"d concrete stem wall
footing with (2) #5 bars cont.
and tt5 transverse bars at 32" o.c.
TYFICAL SECTION
Scale : 1/2" = 1'-0"
24'-C
Thicken ed4e
to 8"x8"
with concrrte
and
none #5 bar 1
ontinuous
------------------
MI I 1 8O 1 11—O O D O ©O
— — — — — — — — ---- — a
-
©I
Fill cell with concrete and w 'do a v o
IT
1
(l) tt5 bar vert. (typical). o g
Max. spacing shall not exceed 1
I
32" unless otherwise noted
1 see foundation plan notes for m I C
O
spacing at openings m
r
I
1 16"w x 16"d concrete stem wall I I v W
footingg with (2) tt5 bars coat.
and 45 transverse bars at 32" o.c. I N
°1:1a�-----
I 00 o i)o
"
I
I•I
�I
,I
I
---
�
I � I
I
I `Ir
I
I
1
I 6" X 6"
PT
I 4" concrete slab with fibermesh OR I
r I
bood
1 6"x6" 410/10 WWM on 6 mil Visqueen over I
I L—
U"x36"A2"
concrete
clean compacted termite treated fill I
I I
with (5)
#5 bars
I"
I
I
ilep I
l
o
l I
Thicken)Edge
to 8"x8'
I I
I with c6
crete and
I I
I one 45 (ar
continuous
I I
Fill cell with concrete and
(1)45 bar Vert. (typical). I
I
I
Max apacing shall not exceed O
32" unless otherwise noted 16'w x I6"d concrete stem wall I
I L -
I
i
y
see foundation plan notes for footing with (2) tt5 bare cont.
and tt5 transverse bars at 32" o.c. I
I
I spacing at openings
— — —
--- --©O-i
I I
Q—_-------
O O i i i i i i i 0 0E)
QQ—
--------- —I---�— — — — — — — — — — — — —
I
O_
_ I Thicken edge to 8"x8"
o I with concrete and
0
one #5 bar continuous
1
I I -� I--------�
117 F—
f---
—i
1T—
L___ X 6" PT Wood Posh -OM
36"x36"x12" concrete column footing
with (5) U5 bars each way
23'-10"
30'-C
FOUNDATION
FLAN
Filled Cell Masonry Column With One
#5 From Footing To Beam.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled
Post on
olumn footing
ach way
ell Column
NTS
I
I
li
II
II
II
II
I
II
I I
II
II
II
II
L�—
�
E
O
m
— — — — —
— —
LL—
— — — — — — — — —
30 min.
Corner Steel La
FOUNDATION NOTES: SCALE: 1/4"
= 1'-0"
I.
Any changes to plans must be submitted to the architect
4j
Epox Mr.
for approval before proceeding with construction.
2.
Contractor shall be responsible for verification of all notation and
dimensions
prior to start of construction.
M
I SSe C�
3.
ALL Concrete used for slabs shall be 3,000 PSI concrete min., and
ALL Concrete used for vertical filled cells, continuous. tie beams etc..
to
shall be 3,000 F.B.I. concrete and/or 4,000 P.S.I. grout mix min.
4.
Soil conditions assumed to be 2900 psf and stable. This shall be
confirmed
Contractor shall remove
by 95% dry soil density test which shall be provided in writing to
this firm by
owner/contitudbteopeeded for new lintel
prior to start of any construction.
5.
Verify all recess thickness at shower floors, all floor finishes as selected
by
Provide Cast -Crete
owner, door sills t thresholds etc.... an slabs,
prior to placing
P P g y
8U9-IB/IT precast
lintel set in mortar
6.
Contractor to provide filled cell with concrete and I #5 bar vert.
at 32"
Min. 4" Bearing
o.c, max. Provide (1) filled cell on each side of openings up to 5'-11"
wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-II"
CBS WALL
;
and Provide (3) filled cells on each side of openings from 10'-0"
and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section) VERT. tt5 bar
1. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-l6 and
A-35 specifications. ALL Anchors to be A-30"I steel. Pour sill blocks
solid for window
9. Provide a minimum of 3" concrete protection at footings and attachment
1-1/2" concrete protection at beams for ALL reinforcing bars.
10. Contractor to provide the Architect with truss shop drawings including
Extend filled cell
up into beam \
Provide New PT
Bucks attached I
jamb details into
existing filled call
See plan
for size
nts
Dowel (1) #5 bar
w/ 25" min lap
and 6" embed
ete Footing
nts
Now Lintel shall
have min. 4" bearing
on each side of new
opening
Provide new filled call
on each aide of opening
ALL truss cut sheets showing ALL truss reactions prior to START See foundation plan I I
OF FOUNDATION WORK for strap and footing size verification. DETAIL AT WINDOW OPENINGS
11. Concrete stoops shall slope away from house Scale. 1/2"-
R�
Sheet
3
Comm #
18-234
Window Schedule
Mark
Size
Window Description
I.
3'—I" x 5'-3"
SINGLE HUNG
2.
4'-5" x 3'-2"
SINGLE HUNG
- ALL Windows to be white ESP aluminum windows with tint.
Provide muntin's and structural mullions per elevations. See
product approval chart for window manufacturer information.
- ALL windows to withstand Pressures stated in Permit
Information Box on these plans.
- ALL windows in bathrooms to be tempered
- ALL windows within 18" of finished floor to be tempered
unless impact rated.
- verify afl masonry/rough opening sizes prior to ordering
windows.
Door Schedule
Mark
Size
Door Description
A
3'—O" X C-8"
SOLID CORE — FIBERGLASS
B
2'-8" X C-8"
MDF 2 PANEL
C
X—L" x C-8"
MDF 2 PANEL POCKET
D
4'-0" x C-8"
LOUVERED BI—FOLD
E
5'-0" X 6'-8"
LOUVERED BI—PASS
F
3'—O" x L'-8"
SLIDING BARN DOOR
G
2 3'-0" X L'-8"
IMPACT GLASS SLIDING DOORS
H
L'—O" X 6'-8"
LOUVERED BI—PASS
- ALL exterior doors including garage doors to withstand
pressures stated in permit information box on these plans.
- verify all masonry/rough opening sizes prior to ordering
windows.
- See product approval chart on these plans for exterior
door manufacturer information (including garage door)
- Provide one exit door (swing type) that is 3'-0" wide
minimum and one emergency escape door (not shuttered).
If escape door has gglazing then it must be impact resistant
and shall NOT be thrU garage. This may be the same door
if it meets both criteria listed above.
FLOOR PLAN
TYPICAL NOTES:
L Contractor to verify ALL notes and dimensions prior to
proceeding with work.
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
S. ALL Concrete used for slabs shall be 2500 PSI concrete, and
ALL Concrete used for vertical filled cells, continuous. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws.
1. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Pan t Drain at water heater in accordance
with the Florida Plumbing Code current edition.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12. Lowest finished floor to be set bg Governing Building Department
surveyor to set in field.
13. Wall and Ceiling shall have a flame —spread classification of not greater than 200
14. Wall and ceiling finishes shall have a smoke —developed index of not greater than 450
ood Post on
to column footing
irs each way
bUALt 1/9" = I'-
15. All exposed attic insulation materials installed on attic floors shall have a critical radiant
Flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. Residential Section R314 — see ermit info box of code edition
I6. Csgpsum board material shall conform to ASTr C36, C19, C415, C514 C630, C931
C960, C1002, C1041,0111, C1118, C1218, C1395, or C1396 and shall be installed
according to the following:
Drgwall
Thickness
Location
Orientation
Framing
Member
spacing
Mawmum
Max, spacing
of fasteners
Nail wing options for
installation ggof drggwall into
2. x Minm�throkne ears
Neils
Screws
Ceiling
Perpendicular
24'
1"
12"
13ga 1 3/8" long with 19/G4" head
�2 „
0.098' diameter x 1 1/4" [an
annular -ringed or 5d cooler U
R
0.080" dmax 1 5/8" long with
15/44' head
Walls
Either
Direction
14,
a.
10
OR
Ggpsum board nail 0.084" dia.
x 15/8" with 9/32' head.
Ceiling
Perpendicular
24"
9'
12"
139a 1 5/8' long with 19/11 head
„
0.098" diameter x 1 3/8" long
annular —ringed or Gd coder ria
OR
0.092' dia. x 11/8" long with
1/4" head
Walls
Either
Detection
IG'
g•
IG•
OR
Gy1psum board nail 0.0915" dia.
x 1/8' with 19/44• head.
11. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
18. Cement, fiber —cement or glass mat ggypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
to
m
Ron
0
L�;
N
m
<toO
> OD M
QdLnOD
N �
a,O
c Cl C4
>` 0000
u U
E
OQ
I 1
Q"
a -
Or0 Oro
oC4N
F#
1p
to N N
q) 19
L
m
++ rr
�Ir
`a
ouiwr�
N
dl
t!
1�1
cV
E IL
1L
-0
0
N
5-f
Sheet
2
OF
Comm #
18-236
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 4TH Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Speed: 140 mph ultimate
Mean Roof Height. 15'-0" Roof Pitch: 4:2
Internal Pressure Coif is ent: ±O_I8
Subjectabilitg to damage from: Weathering: Negligible Termites: Vera Heav4
Width of Roof End Zone: 5'-4"
Wind Exposure Classification. B
Adjustment factor for Exposure Height Using Allowable Stress Design and
Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+O.bWL; 0.4DL+O.4WL
Exp Height Ad j Factor: 1.00 x Load Combo Factor 0.4 = 0.4 applied below
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +I1.0/-21.0 psf
Roof Zone. 2. +I1.0/-48.0 psf
Roof Zone: 3. +I1.0/-10.0 psf
Components
t Cladding Wall End Zone Width:
5'-V
Components
t Cladding Wind Pressure (NET)
Wall Zone:
4. +30.0/-32.0 psf
Wall Zone:
S. +30.O/-40.0 psf
Components
t Cladding Wind Pressure (NET)
on Garage
Door. N/A psf
Shear Walls
Considered for Structure? Yes
Continuous Load Path Provided? e
Are Components
an Cladding Det� Provided?
Yes
Minimum Soil
Bearing Pressure. 2,500 psi, Presumptive:
X By Test: psi
This Building
Shall Have the Following:
APPROVED
SHUTTERS. IMPACT GLASS:
X BOTH:
NEITHER:
IF
GABLE ROOF Ll88
THAN 2.12 PITCH
a - Roof Zone 1 - Roof Zone 2
Walls Zone 4 Walls Zone 5
END ZONE
GABLE ROOF FROM
2.12 TO 12:12 PITCH
- Corner Zones
Root Zone 3
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
NNUAM/BER
Product
Model
#
Manufacturer
Glass
Attachment method
TEST
Date
Maximum
Design Pressure
of Approved Tests
1.
FL# 5823.1
Single Hung
CWS
Impact
custom window
systems
5116"
1/4" dia. tapcons w/ min. 1 3/e" penetration to be
spaced per product approval. Contractor shall adhere to
min. edge distances specified in Product approval
+ 80.0 PSF
—
2.
FLU 11103.1
Sliding Glass
Door
8900 PVC
SGD
custom window
systems
I" nom
Type "GSA'
Is/4" dia.tap oduct /min. 1 approval. penetration
ctor iohalloadhere to
min. 2 I/2" edge distances specified in Product approval
± 60.0 PSF
3.
FLU 14011.5
InswingFlberLast
Impact French Jeld-Wen
P
3/16" dia. x 3" Topcons w/ min. 1 1/2" penetration spaced
per product approval. Contractor shall adhere to edge
distances stated in approval.
+ 45.0 PSF
—
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
mgriTEST
xpu•ation
Date
DesMaxign Pre n
Des n Pressure
of Approved Tests
Mullions
Roof
FLU 11115J
5V 24rimgp Metal
a.
Southeastern Metals
Southeastern Metals Sv Crimp Roofing installed per approval
over Polyglass peel and stick underlayment over 19/32" CD
sheeting nailed to trusses per nailing pattern detail on roof pl
n
-11.0 psf Field an
perimeter.
-93.5 psf corner
Siding
STUCCO
ON BLOCK
5/8" Thick light textured stucco on typical
Concrete block construction
Soffit
FLU 13265.1
Hardi-Soffit
James Hardie Products
Install hardi soffit nailed to 2" x 4" soffit framing at max.
24" o.c. with 1.5" lonp x 0.083" shank dia. x 0.181" HD
ring shank nails at 8 o.c. field and edges IAW product
approval and manufacturers req.
- 83.0 PSF
ALL Product
Testing by: Miami -Dade County Building Code Compliance Office / Product Control Division
I have reviewed
the above and
approved it by my seal below. ( Architect or Engineer of Record )
Diagonal bracing to be
2" x 4" to span
8'-0" from gable end
nailed to each truss
2" x 4" PT Brace
Expansion Anchors
G�4SLE
19/32" COX plywood sheeting
nailed per roof sheeting attachment
detail on roof plan sheet
Soffit and fascia - see
typical section for exact details
FRONT ELEVATION 1/.41'
RIGHT SIDE ELEVATION 1/411
S
p
ro
to
ithet
prouct
fing
trus
tern
nderlagme
s p
Met
ppro
r sh
Is 21
al F
t ov
et",
ga
# III
r 19
att
v
5.1
32"
hme
imp
ver
co)ply
die
etal
ofgglass
ram
Roo
ood
n r
no i
If a
ttac
f pl
tall
here
ed
n
2" x 4" top plate I I 5/8" drywall ceiling on
truss bottom cord LEFT SIDE ELEVATION
2" x 4" sub -fascia o
F
1/8" thick light textured stucco
on plastic lath over 2 Layers of 151b felt
on P9/32" CDX plywood nailed 6" on edge c 1/2" drpwall on
and 12" in field w/ IOd gale. nails u 2" x 4 studs at 16" o.c.
Finish to match existing
w
w
Concrete beam - see schedule on roof plan
r2" x 4" P.T. bottom plate
4" concrete slab with fibermesh OR
Typical baseboard Vx6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
ENE)UJ,4LL DETAIL (1211)
NTS
Interior Non -Bearing Partftlon
Scale: 1/2" = 1'-0"
12
3 1 SLOPE
5/8" thick light textured
stucco on typical concrete
block construction
5/8" thick light textur
stucco on typical concre
block construction
12
SLOPE 14
I�'lll'�I
12
SLOPE 13
��
C
3
�rl1�y�
�
0 00
q N
Q
U
U
01
IL
N
m
III
4- Q
�o
�
<
�>00M
L,
20
C NN
q =4DOD
u0
EOQ
AIL
or- r-
�#
8NN
2
R
1
NuNN-ucr
cuiWrr(Q,Cr,r.
N
4J
th
ysF
�Q
fu
U-
E ll
I
r,
Sheet
REAR ELEVATION
OF
Comm #
18-236