HomeMy WebLinkAbouthealth department approvalAPPLICATION #:AP1454065
STATE OF FLORIDA
PERMIT #:56-SF-2017788
- DEPARTMENT OF HEALTH
#:F11587477
y
SYSTEM
DOCUMENT
ONSITE SEWAGE TREATMENT AND DISPOSAL
PAID:11/20/2019
`y CONSTRUCTION INSPECTION AND FINAL APPROVAL
DATE
FEE PAID:545.00
RECEIPT #:56-PID-4235313
APPLICANT: Marius Bradescu
AGENT: Bruce Mc Cullers (Reliable Treasure Coast Services)
PROPERTY ADDRESS: 7605 Roberts Rd Fort Pierce, FL 34951
LOT: 2 BLOCK: 14
SUBDIVISION: Lakewood Park ID#: 1301-602-0072-000-0
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01] TANK SIZE [1] 900.00 [21 [
] [271
SURFACE WATER FT
[ ] [021 TANK MATERIAL Concrete [
] [281
DITCHES FT
[ ] [031 OUTLET DEVICE [
] [291
PRIVATE WELLS 80 FT
[ ] [041 MULTI -CHAMBERED [Ey N ] [
1 [301
PUBLIC WELLS FT
[ ] [051 OUTLET FILTER Polylok PL-68 [
] [311
IRRIGATION WELLS FT
[ ] [061 LEGEND 1. 28-015-04DC3 2. [
] [321
POTABLE WATER 5 FT
[ 1 [071 WATERTIGHT [
1 [331
BUILDING FOUNDATIONS 6 FT
[ ] [081 LEVEL [
1 [34]
PROPERTY LINES 11 FT
[ ] [091 DEPTH TO LID [
] (351
OTHER FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ 1 [101 AREA [1] 375 [21 SQFT [
] (361
DRAINFIELD COVER
[ ] [111 DISTRIBUTION BOX HEADER X [
] [371
SHOULDERS
[ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [
] [381
SLOPES
[ 1 [131 DRAINLINE SEPARATION [
] [391
STABILIZATION 03/08/2021
[ ] [141 DRAINLINE SLOPE
[ ] [151 DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [161 ELEVATION [ ABOVE / BELOW ]BM 4.00 [
] [401
UNOBSTRUCTED AREA
[ 1 [171 SYSTEM LOCATION [
1 (41)
STORMWATER RUNOFF
[ ] [181 DOSING PUMPS [
] [421
ALARMS
[ 1 [191 AGGREGATE SIZE [
] [431
MAINTENANCE AGREEMENT
[ ] [201 AGGREGATE EXCESSIVE FINES [
] [441
BUILDING AREA
[ ] [211 AGGREGATE DEPTH [
] [451
LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL [
] [461
FINAL SITE GRADING
[ ] [221 FILL AMOUNT [
1 [471
CONTRACTOR Bruce T Mc Cullers (Reliable T
[ ] [231 FILL TEXTURE [
] (481
OTHER ADS MPS-9 (9 pipes - 2 tier)
[ ] [241 EXCAVATION DEPTH
ABANDONMENT
[ ] [251 AREA REPLACED [
] [491
TANK PUMPED
[ ] [261 REPLACEMENT MATERIAL [
] [501
TANK CRUSHED & FILLED
Comments: Comments are on page 2.
/
St. Lucie CHD DATE: 05/28/2020
CONSTRUCTION I APPROVED
DISAPPROVED ] ' nviro ental Specialis II
J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED ] :
St. Lucie CHD DATE: 03/08/2021
Environmental Specialist
Brian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1 AP1454065
EID2017788
�IE
K
a 4" STATE OF FLORIDA
} DEPARTMENT OF HEALTH
c '�+ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
�y CONSTRUCTION INSPECTION AND FINAL APPROVAL
w W, s
Violation Number Comment
Comments
APPLICATION # : AP 1454065
PERMIT #:56-SF-2017788
DOCUMENT #:F11587477
DATE PAID:11/20/2019
FEE PAID:545.00
RECEIPT #:56-PID-4235313
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
New ST, filter, and 3x31+1x32 long TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs
final inspection for well inspection/setback, mound system, gutters, and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1454065 EID2017788