Loading...
HomeMy WebLinkAboutEnergy Codey. FORM R405-2014 l 4 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation = Residential Performance Method Project Name: Standard Pacific RB Wentworth Lot 10 Builder Name: Standard Pacific Homes Street: 3034.NW Radcliffe Way Permit Office: Port St Lucie City, State, Zip: Port St Lucie , FL , Permit Number: Owner: Standard Pacific Homes Jurisdiction: 461100 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (6556.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 6023.40 ft2 b. Frame - Wood, Adjacent R=11.0 373.45 ft2 3. Number of units, if multiple family 1 c. Concrete Block - Int Insul, Adjacent R=4.1 160.05 ft2 4. Number of Bedrooms 7 d. N/A R= ft2 10. Ceiling Types (3300.0 sqft.) Insulation Area 5. Is this a worst case? No 1 a. Cathedral/Single Assembly (Unvented) R=20.0 3300.00 ft2 6. Conditioned floor area above grade (ft2) 5879 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. VUndows(931.2 sqft.) Description Area a. Sup: AC 1 Club Room Living Room Bed, Ret: AC 6 175 a. U-Factoir: Sgl, U=1.07 414.07 ft2 b. Sup: AC 2 Family Kitchen Dining Foy, Ret: AC 2 6 150 SHGC: SHGC=6.30 i c. Sup: AC 3 Second Floor, Ret: AC 3 Second Floor, 6 275 b. U-Factor: Sgl, U=1.00 258.99 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 30.0 SEER:14.00 b. Central Unit 44.5 SEER:14.00 c. U-Factor: Sgl, U=1.05 240.00 ft2 c. Central Unit 41.0 SEER:14.00 SHGC: SHGC=0.28 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.18 ft2 a. Electric Heat Pump 29.6 HSPF:8.20 SHGC: other (see details) b. Electric Heat Pump 45.0 HSPF:8.20 Area Weighted Average Overhang Depth: 7.566 ft. c. Electric Heat Pump 38.5 HSPF:8.20 Area Weighted Average SHGC: 0.301 14. Hot water systems a. Electric Cap: 80 gallons 8. Floor Types (3300.0 sqft.) Insulation Area EF: 3.100 a. Slab -On -Grade Edge Insulation R=0.0 3300.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.158 Total Proposed Modified Loads: 150.36 PASS Total Baseline Loads: 159.17 I hereby certify that the plans and specifications covered by Review of the plans and fla ST,gZ� this calculation are in compliance with the Florida Energy Digitally specifications covered by this __ p �v�j Code. signed by Chds.Wildroudt ('� h DNi en=Chris Wildroudt, c=US, rI S Chris calculation indicates compliance 'c •�. o=Erigineered Air, LLC, ou=Sales with the Florida Energy Code. F /m, n.. •.;;; ; ;,.�, „ O , PREPARED BY: and Engineering email-Christy@engineeredairilc. DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 4. d *. Date: 2016.10.2615:30:24-04'00' I herebycertify that this building, as designed, 'is in com compliance fY 9,I P the Florida Energy Code. Florida Statutes. OA with OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 10/26/2016 3:28 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant are Page 1 of 6 FC9RM R405-2014 PROJECT Title: Standard Pacific RB Wentwor Bedrooms: 7 Address Type: Street Address Building Type: User Conditioned Area: 5879 Lot # 10 Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: 3034 NW Radcliffe Way Permit Office: Port St Lucie Cross Ventilation: County: St. Lucie Jurisdiction: 461100 Whole House Fan: City, State, Zip: Port St Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1465 15631.5 2 Block2 2011 28649.7 3 Block3 2403 22420 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 Club Room Li 1465 15631.5 No 3 1 1 Yes Yes Yes 2 AC 2 Family Kitche 2011 28649.7 Yes 3 0 1 Yes Yes Yes 3 AC 3 Second Floor 2403 22420 No 4 6 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1. Club Room 173 ft 0 1465 ftZ _-__ 0 0 1 2Slab-On-Grade Edge Insulatio AC 2 Family Kitch 183 ft 0 1835 ftZ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 3574 ftZ 0 ftZ Light 0.5 No 0.5 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic invented 0 3300 ftZ N N 10/26/2016 3:28 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 W FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (UnvAQERiFamily Kitch 20 697 ft2 0.11 Wood 2 Cathedral/Single Assembly (UnvekTaa Second Flo 20 2603 ft2 0.11 . Wood WALLS Ornt Adjacent S# Space To IALgIl Typepace CavR_Vaity Width Height Sheathing Framing Solar . Belo w 1 E Exterior Concrete Block - Int 1 Club Ro 4.1 9 0 10,67 0 96.0 ft2 0.3 0 0.3 0 2 S Exterior Concrete Block - Int Ins= 1 Club Ro 4.1 56 0 10.67 0 597.5 ft2 0.3 0 0.3 0 3 W Exterior Concrete Block - Int'nsAC 1 Club Ro 4.1 22 0 10.67 0 234.7 ft2 0.3 0 0.3 0 4 W Exterior Concrete Block - Int InsAC 1 Club Ro 4.1 29.5 0 10.67 0 314.8 ft2 0.3 0 0.3 0 5 N Exterior Concrete Block Int InsAC 1 Club Ro 4.1 14.5 0 10.67 0 154.7 ft2 0.3 0 0.3 0 6 N Exterior Concrete Block - Int InsAC 1 Club Ro 4.1 14 0 10.67 0 149.4 ft2 0.3 0 0.3 0 7. E Garage Frame -.Wood AC 1 Club Ro 11 16 0 10.67 0 170.7 ft2 0.3 0 0.3 0 8 E Garage Concrete Block - Int InsAC 1 Club Ro 4.1 6 0 10.67 0 64.0 ft2 0.3 0 0.3 0 _ 9 S Garage Frame - Wood AC 1 Club Ro 11 6 0 10.67 0 64.0 ft2 0.3 0 0.3 0 -10 E Exterior Concrete Block - Int InstAC 2 Family 4.1 12 0 10.67 0 128.0 ft2 0.3 0 0.3 0 _ 11 E Exterior Concrete Block - Int InstAC 2 Family 4.1 12 r 0 10.67 0 128.0 ft2 0.3 0 0.3 0 12 E Exterior Concrete Block - Int InsiAtC 2 Family 4.1 9 0 10.67 0 96.0 ft2 0.3 0 0.3 0 _ 13 S Exterior Concrete Block - Int InsiAgC 2 Family 4.1 18 0 21.67 0 390.1 ft2 0.3 0 0.3 0 _ 14 W Exterior Concrete Block - Int InstAC 2 Family 4.1 30 0 10.67 0 320.1 ft2 0.3 0 0.3 0 15 W Exterior Concrete Block - Int InsiAC 2 Family 4.1 22.5 0 21.67 0 487.6 ft2 0.3 0 0.3 0 _ 16 N Exterior " Concrete Block - Int InSrAC 2 Family 4.1 19 0 21.67 0 411.7 ft2 0.3 0 0.3 0 17 N Exterior Concrete Block - Int InsrAiC 2 Family 4.1 38.5 0 10.67 0 410.8 ft2 0.3 0 0.3 0 18 E Garage Concrete Block - Int InstAC 2 Family 4.1 9 0 10.67 0 96.0 ft2 0.3 0 0.3 0 19 E Garage Frame - Wood AC 2 Family 11 13 0 10.67 0 138.7 ft2 0.3 0 0.3 0 20 E Exterior Concrete Block - Int InsAC 3 Second 4.1 70 0 9.33 0 653.1 ft2 0.3 0 0.3 0 21 S Exterior Concrete Block - Int InsAC 3 Second 4.1 59 0 9.33 0 550.5 ft2 0.3 0 0.3 0 22 W Exterior Concrete Block - Int InsAC 3 Second 4.1 22 0 9.33 0 205.3 ft2 0.3 0 0.3 0 23 W Exterior Concrete Block - Int InsAC 3 Second 4.1 29.5 0 9.33 0 275.2 ft2 0.3 0 0.3 0 24 N Exterior Concrete Block - Int InsAC 3 Second 4.1 45 0 9.33 0 419.9 ft2 0.3 0 0.3 0 DOORS - # Ornt Door -Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated iAC 1 Club Ro None .4 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1' E 1 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 10 ft 0 in 2.67 ft 0 i None None 2 E. 1 Metal Low-E Single Yes 1 0.32 9.0 ft2 7 ft 0 in 1 ft 0 in None None 3 S 2 Metal Low-E Single Yes 1 0.32 13.3 ft2 1 ft0 in .14.5 ft 0 i None None 4 S 2 Metal Low-E Single Yes 1.07 0.3 61.6 ft2 10 ft0 in 14.5 ft 0 i None None 5 S 2 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft0 in 14.5 ft 0 i None None 10/26/2016 3:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 " �QMA radnr,-,)nle WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth. Separation - Int Shade Screening 6 W 4 Metal Low-E Single .! Yes 1.07 0.3 18.4 ft2 13.5 ft 0 i 2 ft 0 in None None 7 W 4 Metal Low-E Single Yes 1.05 0.28. 30.0 ft2 13.5 ft 0 i 2 ft 0 in None None 8 W 4 Metal Low-E Single Yes 1 0.32 35:0 ft2 13.5 ft 0 i 2 ft 0 in None None 9 N 5 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 0 in 14.5 ft 0 i None None 10 N 6 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 29.5 ft 0 i 2 ft 0 in None None 11 E 10 Metal Low-E Single Yes 1 0.32 9.0 ft2 12 ft 0 in 1 ft 0 in None None 12 E 10 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 12 ft 0 in 2.67 ft 0 i None None 13 E 11 Metal Low-E Single Yes 1 0.3 9.2 ft2 1 ft 0 in 1.33 ft 0 i None None 14 E 12 Metal Low-E Single Yes 1.05 0.32 9.0 ft2 7 ft 0 in 1 ft 0 in None None 15 E 12 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 7 ft 0 in 2.33 ft 0 i None None 16 S 13 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 29.5 ft 0 i 2 ft 0 in None None 17 W 14 Metal Low-E Single C Yes 1.07 0.3 18.4 ft2 13.5 ft 0 i 2 ft 0 in None None 18 W 14 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 13.5 ft 0 i 2 ft 0 in :. None None 19 W 14 Metal Low-E Single Yes 1 0.32 35.0 ft2 13.5 ft 0 i 2 ft 0 in None None 20 W 15 Metal Low-E Single f Yes 1.07 0.3 61.6 ft2 1 ft 0 in 14.5 ft 0 i None None 21 W 15 Metal Low-E Single Yes 1. 0.32 61.6 ft2 1 ft 0 in 8 ft 0 in None None 22 W 15 Metal Low-E Single Yes 1 0.32 61.6 ft2 1 ft 0 in 1.5 ft 0 in None None 23 N 16 Metal Low-E Single Yes 1.07 0.3 18.4 ft2. 1 ft 0 in 14.5 ft 0 i None None 24 N 16 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 1 ft 0 in 1.5 ft 0 in None None 25 N 17 Metal Low-E Single Yes 1.07 0.3 30.8 ft2 1 ft 0 in 14.5 ft 0 i None None 26 N 17 Metal Low-E Single Yes 1.07 0.3 18.4 ft2 1 ft 0 in 14.5 ft 0 i None None 27 E 20 Metal Low-E Single f Yes 1.07 0.3 32.3 ft2 1 ft 0 in 1.5 ft 0 in None None 28 S 21 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft Orin 1.5 ft 0 in None None 29 S 21 Metal Low-E Single Yes 1.07 0.3 27.5 ft2 1 ft 0 in 1.5 ft 0 in None None 30 S 21 Metal Low-E Single Yes 1 0.32 25.0 ft2 1 ft 0 in 1.5 ft 0 in None None 31 S 21 Metal Low-E Single Yes 1. 0.32 9.5 ft2 1 ft 0 in 1.5 ft 0 in None None 32 W 22 Metal Low-E Single Yes 1.07 0.3 48.5 ft2 1 ft 0 in 1.5 ft 0 in None None 33 W 23 Metal Low-E Single ; Yes 1.07 0.3 32.3 ft2 13.5 ft 0 i 1.5 ft 0 in None None 34 W 23 Metal Low-E Single Yes 1.05 0.28 30.0 ft2 13.5 ft 0 i 1.33 ft 0 i None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1005.984 ft2 1006 ft2 i 125 ft 10.67 ft 1 ! INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00036 5558.4 305.15 573.88 .324 5 10/26/2016 3:28 PM Energj Gauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 ',I FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 3 Electric Heat Pump Electric Heat Pump Electric Heat Pump Split Split Split HSPF:8.2 29.6 kBtu/hr HSPF:8.2 45 kBtu/hr HSPF:8.2 38.5 kBtu/hr 1 2 3 sys#1 sys#2 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit Central Unit Central Unit Split Split Split SEER: 14 30 kBtu/hr 1000 cfm 0.75 SEER: 14 44.5 kBtu/hr 1600 cfm 0.75 SEER: 14 41 kBtu/hr 1400 cfm 0.75 1 2 3 sys#1 sys#2 sys#3 HOT WATER SYSTEM # System Type SubType ;Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump. (Garage 3.1 80 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 3 AC 1 Club Ro 6 175 ft2 AC 2 Family 6 150 ft2 AC 3 Second 6 275 ft2 AC 1 Club Ro 45 ft2 Default Leakage AC 1 Club (Default) (Default) AC 2 Family 15 ft2 Default Leakage AC 2 Famil (Default) (Default) AC 3 Second 60 ft2 Default Leakage AC 3 Secon (Default) (Default) 1 1 2 2 3 3 TEMPERATURES Programable Thermostat: Y Coolin Jan Feb Mar Heating Jan . Feb Mar Venting Jan Feb X Mar Ceiling Fans: A r Ma X Jun X Jul Au X Se Oct Apr May Jun Jul Aug Sep Oct Apr May Jun Jul Aug Sep Oct Nov Nov X Nov Dec Dec Dec 10/26/2016 3:28 PM EnergyGau'ge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 - 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/26/2016 3:28 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL.) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 3034 NW Radcliffe Way, Port St Lucie, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2). 7. Windows** Description a. U-Factor: Sgl, U=1.07 (SHGC: SHGC=0.30 b. U-Factor: Sgl, U=1.00 SHGC: SHGC=0.32 c. U-Factor: Sgl, U=1.05 SHGC: SHGC=0.28 d. U-Factor: other (see details) SHGC: other (see details). Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) Single-family No 5879 Insulation R=0.0 R= R= Area 414.07 ft2 258.99 ft2 240.00 ft2 18.18 ft2 7.566 ft. 0.301 Area 3300.00 ft2 ft2 ft2 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 6023.40 ft2 b. Frame - Wood, Adjacent R=11.0 373.45 ft2 c. Concrete Block - Int Insul, Adjacent R=4.1 160.05 ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Cathedral/Single Assembly (Unvented) R=20.0 3300.00-ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: AC 1 Club Room Living Room Bed, Ret: AC 6 175 b. Sup: AC 2 Family Kitchen Dining Foy, Ret: AC 2 6 150 c. Sup: AC 3 Second Floor, Ret: AC 3 Second Floor, 6 275 12. Cooling systems kBtu/hr Efficiency a. Central Unit 30.0 SEER:14.00 b. Central Unit 44.5 SEER:14.00 c. Central Unit 41..0 SEER:14.00 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 29.6 HSPF:8.20 b. Electric Heat Pump 45.0 HSPF:8.20 c. Electric Heat Pump 38.5 HSPF:8.20 14. Hot water systems a. Electric Cap: 80 gallons EF: 3.1 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card. will be completed based on installed Code compliant features.' Builder Signature: Date: Address of New Home: � O 5ci NL,) 20,\pe11W-f- ity/FL Zip:P�¢�- St I.-uu*G *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified. Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/26/2016 3:29 PM EnergyGauge@ USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1