Loading...
HomeMy WebLinkAboutEnergy Codew, i FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: MW-168 Builder Name: GHO BUILDERS RECEIVED Street: 9406 PINEBARK CT. Permit Office: St.Lucie County City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: FEB 12 2020 Owner. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Clir ta e Zone 2 ) ST. Luciecounty, 1. New construction or existing New (From Plans) 10. Wall Type$2378.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Exl Insul, Exterior R=4.1 2068.30 ft2 b. Frame - Wood, Adjacent R=11.0 309.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Types (2284.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 2284.00 ft2 6. Conditioned floor area above grade (ft2) 2284 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(441.2 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 630 a. U-Factor: Dbl, U=0.62 441.15 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 13. Cooling systems kStu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 6.640 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.260 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2284.0 sgft.) Insulation Area EF:0.940 a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 70.94 Glass/Floor Area: 0.193 c C PASS Total Baseline Loads: 72.19 f�1�7�7 I hereby certify that the plans and specifications covered by Review of the plans and STATE this calculation are in compliance with the Florida Enerqy specifications covered by this 0V%E IV p Code.0 calculation indicates compliance � °�,� �O with the Florida Energy Code. ti rnn''� r PREPARED BY: Before construction is completed DATE: 1/15/2021 this building will be inspected for -till,11 a compliance with Section 553.908 * . I hereby certify that this building, as designed, is in compliance Florida Statutes. 6'0D with the Florida Energy Code. WTE OWNER/AGENT: BUILDING OFFICIAL: DATE: 1.I-A ZQ2�� DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1, envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). qualifies as and this project requires an 1/11/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software I Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-168 User 1 GHO BUILDERS StLucie County Detached New (From Plans) Bedrooms: 3 Conditioned Area: 2284 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/Subdi PlatBook: Street: County: City, State, Street Address Ision: 9406 PINEBARK CT. St. Lucie Zip: FORT PIERCE, FL. 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Winter Summer DoIgree Heating Design DallyTemp Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2284 23068.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2284 23068.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 241.1 ft 2284 ft2 _.-- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Barr Absor. Tested I Emilt Emilt Deck Pitch Tested Insul. (deg) 1 Hip Flat tile/slate 2664 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.57 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS I CC 1 Full attic Vented 150 2284 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2284 ft2 0.1 Wood 1/11/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software I Page 2 of 5 GnRnn PAni_gngn INPI IT SUMMARY CHFCKI IAT RFPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space -4.1 Et In Et In Area- P-lialue Fraction Absor Grade% 1 N Exterior Concrete Block - Ext Insul Main 58 2 9 4 542.9 ft' ;0 0 0.3 0 _ 2 NE Exterior Concrete Block - Ext Insul Main 4.1 8 9 11 4 99.2 ft' i0 0 0.3 0 _ 3 E Exterior Concrete Block - Ext Insul Main 4.1 55 7 9 4 518.8 ft' i0 0 0.3 0 4 SE Exterior Concrete Block - Ext Insul Main 4.1 2 11 11 4 33.1 ft' O 0 0.3 0 5 S Exterior Concrete Block - Ext Insul Main 4.1 32 0 11 4 362.7 ft' 0 0 0.3 0 6 W Exterior Concrete Block - Ext Insul Main 4.1 54 10 9 4 511.8 ft' O 0 0.3 0 7 - Garage Frame - Wood Main 11 27 4 11 4 309.8 ft' 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 3 8 24 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 2 ft 0 in 1 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.3 tt' 2 ft 0 in 1 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 31.6 ft' 4 ft 0 in 2 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 111.6 ft' 12 ft 0 in 2 ft 0 in None None 5 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 22.5 ft' 5 ft 0 in 2 ft 0 in None None 6 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 18.7 ft' 10 ft 0 in 2 ft 0 in None None 7 e 3 Metal Double (Clear) Yes 0.62 0.26 N 11.8 ft' 2 ft 0 in 1 ft 0 in None None 8 e 3 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 2 ft 0 in 1 ft 0 in None None 9 e 3 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft' 15 ft 0 in 3 ft 0 in None None 10 se 4 Metal Double (Clear) Yes 0.62 0.26 N 14.0 ft' 2 ft 0 in 1 ft0 in None None 11 s 5 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft' 8 It 0 in 2 ft 0 in None None 12 s 5 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft' 2 it 0 in 1 ft 0 Iin None None 13 s 5 Metal Double (Clear) Yes 0.62 0.26 N 48.0 ft' 2 ft 0 in 1 ft 0 in None None 14 S 5 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft' 8 ft 0 in 4 ft 0 None None 15. w 6 Metal Double (Clear) Yes 0.62 0.26 N 9.0 ft' 2 ft 0 in iin 1 ft 0 in None None 16 w 6 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft' 2 ft 0 in 1 ft 0 in None None 17 w 6 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 2 ft 0 in 1 ft0 �n None None 18 W 6 Metal Double (Clear) Yes 0.62 0.26 N 21.3 ft' 15 ft 0 in 2 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 686 ft' 686 ft' 64 ft 9.3 ft 1 1/1 W021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software I Page 3 of 5 FOPM Pans;-7n7n INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000"9 2691.3 147.65 277.2 .1387 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow, SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtuRu cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Mein 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / — Supply — # Location R-Value Area — Retum — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 630 ft' Attic 320 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar HeatinHJan Feb Mar Ventin Jan Feb Mar Ceiling Fans: A r Ma Jun Jul Au Se E Apr f May Jun Jul E Aug Sep [X] A r [ Ma Jun Jul [ Au Se ct ct wct Nov WNov Nov Dec Dec Dec 1/11/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software I Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule; HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 66 66 68 68 68 68 68 66 PM 68 68 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/sci.ft. 0 ft2 0 ft 0.3 Main 1/11/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software I Page 6 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 98 The lower the EnergyPerformance Index, the more efficient the home. 9406 PINEBARK CT., FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 2068.30 ft2 b. Frame - Wood, Adjacent R=11.0 309.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 2284.00 ft' 6. Conditioned floor area (ft2) 2284 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.62 441.15 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.26 a. Sup: Attic, Ret: Attic, AH: Main 6 630 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 46.5 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.640 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15. Hot water systems : a. Electric Cap: 50 gallons a. U-Factor(AVG): N/A ft EF:0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building THE S7, Construction through the above energy saving features which will be installed (or exceeded) tiok = ATFo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant atures. .��* :`�:,;:,��„ �o Builder Signature: Date: I a - ` 'I ° rr Address of New Home: qL�u(� � C . City/FL Zip: - �t J a� t goo WF *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Floida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/11/2021 1:16 PM EnergyGaugeO'USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7t� Edition Jurisdiction: Permit #: Job�lfocmaion - n� 3� Builder: GHO BUILDERS Community: Lot: NA Address: 9406 PINEBARK CT. I City: FORT PIERCE State: FL Zip: 34951 u Rtl4fekJtod c x :+2a�Etti�iSRt[tS Psssrf .,�ctlis,ttt�i�inee�eiiher the Petfrrttartc,'rexsro�e;o R E M PRE3CRIPTIIIE'Mk'THCMLl The btComg or ce dw>3lintj units(tall beestad°arid venfledsas havirig anarleakege rate of not exeding 7 aiF r Y changes per hour at a pressp otA 2 tticfi mi-77 g {60 F'asGats} in C tmate Pik',! ai►d 2 , , r r. QEF+fiRt1AANCE or�gRt F oEtiThe bui{ding or ci ellfrjgurt`� I be'testedand verified est avin an,ir teaks a rate of root e�xaes�in�= i�f Uon,�sui�-sectlonACH50 -the setected�lGFi(50j�valu`e', as�sh�on fiorn� R4£?5-2020�{Pezf imarce) or R406-2020 {ERI);sa�cUonrtabetetl�as ": ACH(50)spe,t�et�arrFotmR�Fl15:202�E�ner}7Y'(atc{F'eriorrrrar;tce�:drR4082020(Ef�lj 7.000 _..���-e; ._ Ring x 60 + 23068 — Method for calcul building volume: CFM(50) Building Volume ACH(50) Retrieved from O architectural plans FIPASS Code • software) calculated When ACH(50) is less than 3; Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI1RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed as set forth In Section 489.105(3)(0(g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyontl intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recoveryventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, If installed at the time of the test, shall be fully open. Testing MOO , - zN Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. r Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #' Issuing Authority: 1111/2021 1:15:37 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoft9 Load Short Form Entire House For. MW-168' 9406 PINEBARK CT., FORT PIERCE, FL 34951 Htg Clg Outside db (°F) 43 90 Inside db (°F) 70 72 Design TD (°F) 27 18 Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 0 68 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 10.0 kW 34035 Btuh 20 OF 1567 cfm 0.048 dmA3tuh 0 in H2O Job: Date: Jan 11, 2021 By. Method Simplified Construction quality Tight Fireplaces 0 COOLING E Make Lennox Trade LENNOX Cond ML14XC1-047=2 Coil CBA27UHE-048 AHRI ref 10259428 Efficiency 13.0 Sensible cooling Latent000ling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 16 SEER 32900 Btuh 14100 Btuh 47000 Btuh 1567 cim 0.048 Cfm/Btuh 0 in H2O 0.74 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (fie) (Btuh) (Btuh) (cim) (cfm) MASTER SUITE 385 5759 5259 277 251 HER WIC 45 39 230 2 11 HIS WIC 86 1214 724 58, 35 GREAT ROOM 435 5282 5631 254. 269 DINING 159 2946 2680 142 128 FOYER 57 1254 995 60 48 NOOK 95 2522 2604 121 124 KIT 210 178 1670 9 80 BED 3 147 1562 2862 75 137 BED3WIC 33 1051 620 51 30 CABANA 76 2098 1293 101 62 BATH 2 60 1446 1129 70 54 UTILITY 49 197 694 9 33 MECH 36 860 631 41 30 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. * wreghtsfta ti+-i^-ltt.- aft— Right-Sute®Uriversal202121.0.02RSU29964 •.•rsWyUserUcLsnerblWdgttsoRHVACWIW-168np Cala=W8 FrordDoorboewS 2021-Jan-1214:41:04 Page 1 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsotii- 2021-JorF1214:41A4 ►, •�-�w-. ..�. RighMfe®Uriverw1202121A.02RSU29964 �A1sAryUseADoamarts%WrigNsoRHVAOMW-16anp Cale -We FwtDooriaaas: S Paget f�F wrightsoft° Project Summary Entire House For: Notes: MW-168 9406 PINEBARK CT., FORT PIERCE, FL 34951 Weather: Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 26886 Btuh Central 5660 BBttuuh vent (0 crm) (none) Humidification 0 Btuh Piping Btuh Equipmentload 32554 Infiltration Vero Beach, FL, US Method Simplified Construction quality Fireplaces Tight 0 He228q Coo228g Area (�) Volume (fl') 23185 23185 Air changes/hour 0.11 0.06 Equiv. AVF (cfm) 43 23 Heating Equipment Summary Make Trade MHRIAref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 10.0 kW 34035 Btuh 20 OF 1567 cfrn 0.048 cfrn/Btuh 0 in H2O Calculations approved Summer Design Outside db Inside db Design TD Daily range Relative humidity Moisture difference Sensible Cooling Equipr Structure Ducts Central vent (0 cfm) (none) Blower Use manufacturer's data Rate/swingg multiplier Equipment sensible load Latent Cooling Equipm Structure Duds Central vent (0 cfm) (none) Equipment latent load Equipment Total Load (Sen+Lat) Req. total capacity at 0.70 SHR Cooling Equipmen Make Lennox Trade LENNOX Cond ML14XCl-047-230M Coil CBA27UHE 048-230* AHRI ref 10259428 Effciency 13.0 EE Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio to meet all requirements of Manual J 8th Ed. Job: Date: Jan 11, 2021 BY 90 OF 72 OF 18 OF 50 % 68 grAb Load Sizing 25789 Btuh 7000 BBtuh 0 Btuh n 0.95 31152 Btuh Load Sizing 9319 Btuh 2280 BBWh 11604 Btuh 42757 Btuh 3.7 ton t Summary TDR 16 SEER 32900 Btuh 14100 Btuh 47000 Btuh 1567 cfm 0.048 cim/Btuh 0 in H2O 0.74 -FO- wrtghtsoft- Z021Jer►1214:4104 •�� RighESLit*Uriwrsa1202121.0A2RSU29964 ACM ..rfA rVOMEf fAWri9tsoftWACUW-168Ap Ca1c=MJ8 FrortDoorlaces: S Page I 9406 PINEBARK CT FORT PIERCE, FL 34951