HomeMy WebLinkAboutMullion Connection AnalysisNATIONAL CERTIFIED TESTING LABORATORIES FIVE LEIGH DRIVE • YORK, PENNSYLVANIA 17406 • TELEPHONE (717) 846-1200 FAX (717) 767-4100 www.nctlinc.com RECEIVED FEB 12 2020 ST. Lucie county, Permitting MULLION CONNECTION ANALYSIS REPORT TO: MANNING BUILDING SUPPLY 3315 OLEANDER AVENUE FORT PIERCE, FLORIDA 34982 REPORT NUMBER: NCTL-110-23899-1 REPORT DATE: 12/19/20 oS�pH A. * . No. 58920 STATE OF A, s '4 ORVD �ONIA`,��,,,,. Joseph A. Reed, PE FL PE 58920 FL REG 33474 2020.12.21 07:12:20-05'00' Professionals In The Science of Testing Manning Building Supply f� NCTL-110-23899-1 Mullion Connection Analyses Page 1 of 11 S National Certified Testing Laboratories (NCTL) was contracted by Manning Building Supply to perform an engineering analysis connections between intersecting vertical and horizontal mullions. Specifically, MI Windows and Doors CM-18531 and CM-18532 mullions used on various GRBK GHO Homes, LLC projects. This report presents the calculation of mullion reactions for various size windows and design pressures as supplied by Manning Building Supply. Connection methods between the horizontal and vertical intersecting mullions are proposed and validated for the calculated mullion reactions. Referenced standards utilized for this project include: Florida Building Code, Building, 6rh Edition (2017). International Code Council, 2017. ADM 1-2015 2015Aluminum Design Manual. The Aluminum Association, Inc., 2015. AAMA TIR A9-14 Design Guide for Metal Cladding Fasteners. American Architectural Manufacturers Association, 2014. The analyses presented herein consider only the structural capacities of the mullion connections. The ability of the proposed connection methods to resist air infiltration, water infiltration, water penetration, windborne debris impact, thermal effects or fire is not within the scope of the analyses. This report does not evaluate the windows, window installations, mullions or mullion installation to the building substrate. Manning Building Supply NCTL-110-23899-1 (� Mullion Connection Analyses Page 2 of 11 Analyses Mullion Reactions The evaluated window elevations are presented on page 4 to page 8. Mullion reactions for the design pressures supplied by Manning Building Supply are calculated on page 9. A summary of the calculated mullion reactions is presented in Table 1. Table 1 Mullion Reactions Window Design Pressure Mullion San Panel Widths Mullion Reaction Type A 34.3 psf Bottom Vertical 72" 37" 236 lb Type B 34.2 psf Bottom Vertical 63" 53" 230 lb Top Vertical 24" 53" 34lb Type C 33.5 psf Bottom Vertical 72" 37" 230 lb Top Vertical 20" 37" 23lb Type D 32.7 psf Bottom Vertical 63" 37" 187 lb -Type E 33.7 psf Bottom Vertical 72" 53" 282 lb Top Vertical 24" 53" 34lb The maximum mullion reaction for the bottom vertical mullion is 282 lb. The connection between the horizontal mullion and the bottom vertical mullion shall be designed for this load. The maximum mullion reaction for the top vertical mullion is 34 lb. The connection between the horizontal mullion and the top vertical mullion shall be designed for this load. Mullion Connection Analysis The proposed connections between the intersecting mullions are evaluated for fastener shear capacity and allowable bearing stress between the fasteners and the components of the connection. Calculations are presented on page 10 to page 11 and summarized in Table 2. Table 2 Summary of Mullion Connection Analysis Connection I Components Capacity Horizontal Mullion to MI Windows CM-18531 or CM-18532 mullions Bottom Vertical Mullion (2) #10 x 2 screws 432 lb see page 10 MI Windows CM-18531 or CM-18532 mullions (2) 1-1/2" x 1-1/2" x 0.093" thick aluminum Top Vertical Mullion to angles; 1-1/4" long; 6063-T5 aluminum. Horizontal Mullion (2) #10 x 5/8" screws each angle; one screw in 260 lb each leg of each angle; screws may be countersunk in angle. see page 11 The capacities of the connections evaluated in Table 2 exceed the mullion end reactions thereby validating the connections for the window sizes and design pressures evaluated in this report. Manning Building Supply NCTL-110-23899-1 Mullion Connection Analyses Page 3 of 11 Attachments Appendix A — Revision Log (1 page) Manning Building Supply NCTL-110-23899-1 Mullion Connection Analyses Page 4 of 11 Window Elevations WINDOW TYPE A NN N N i 74' Manning Building Supply �I��j NCTL-110-23899-1 Mullion Connection Analyses Page 5 of 11 WINDOW TYPE 8 N I I { 1os• Manning Building Supply NCTL-110-23899-1 .% Mullion Connection Analyses Page 6 of 11 WINDOW TYPE C 74 Manning Building Supply lcrl�j NCTL-110-23899-1 Mullion Connection Analyses Page 7 of 11 WINDOW TYPE D Manning Building Supply,( NCTL-110-23899-1 Mullion Connection Analyses Page 8 of 11 WINDOW TYPE E N N n 1os• Manning Building Supply Tv Mullion Connection Analyses Mullion End Reactions Design Pressure Mark (PSF) h (inch A 34.3 72.0 B - Bottom 34.2 63.0 B - Top 34.2 24.0 C - Bottom 33.5 72.0 C-Top 33.5 20.0 D 32.7 63.0 E - Bottom 33.7 72.0 E - Top 33.7 24.0 i- a h NCTL-110-23899-1 Page 9 of 11 a (inches) b (inches) Al (ft2) A2 (ft2) R (lb 37.0 37.0 6.87 6.87 236 53.0 53.0 6.72 6.72 230 53.0 53.0 1.00 1.00 34 37.0 37.0 6.87 6.87 230 37.0 37.0 0.69 0.69 23 37.0 37.0 5.72 5.72 187 53.0 53.0 8.37 8.37 282 53.0 53.0 1.00 1.00 34 Al A2 b -� Manning Building Supply ,j�,J Mullion Connection Analyses Connection of Horizontal to Bottom Vertical #10 X 2- INTO VERTICAL MULL NCTL-110-23899-1 Page 10 of 11 CM-16532 ANCHOR BRACKET 5766 �/ I �CM-16531 ANCHOR BRACKET 5766 Secure horizontal mullion to vertical mullion with two (2) #10 x 2" screws through horizontal mullion to screw, race of vertical mullion. #10 x 2" Grade 2 Screws CM-18531 Aluminum Mullion with 0.125" wall thickness CM-18532 Aluminum Mullion with 0.125" wall thickness 6063-T5 Aluminum (Fy = 16,000 psi, Fu = 22,000 psi) Shear Capacity of #10 x 2" Grade 2 Screw Va = 216 lb (AAMA TIR A9-14) Bearinq Capacity of #10 x 2" Grade 2 Screw at Horizontal Mullion Va = 2(D)tFuA2 Va = (2)(0.190")(0.125")(22,000 psi)/3.0 = 348 lb Capacity of one screw is 216 lb Capacity for Connection with Two Screws is 432 lb Manning Building Supply Ocrlj� NCTL-110-23899-1 Mullion Connection Analyses Page 11 of 11 Connection of Top Vertical to Horizontal 2 x 1-1/2 x .093 by 1-1/4" Long -ium Angle (Each Side of Vertical) - #10 screw securing Ingle to mull Horizontal Mull CM-18531 or CM-18532 Secure top vertical mullion to horizontal mullion with two (2) 3/32" thick aluminum angles (one each side of mullion). #10 x 5/8" Grade 2 Screws CM-18531 Aluminum Mullion with 0.125" wall thickness CM-18532 Aluminum Mullion with 0.125" wall thickness 3/32" (0.093") thick Aluminum Angle 6063-T5 Aluminum (Fy = 16,000 psi, Fu = 22,000 psi) Shear Capacity of #10 x 5/8" Grade 2 Screw Va = 216 lb (AAMA TIR A9-14) Bearing Capacity of #10 x 5/8" Grade 2 Screw at Aluminum Angle Va = 2(D)tFu/i2 Va = (2)(0.190")(0.093"/2)(22,000 psi)/3.0 = 130 lb (t/2 for countersunk) Bearing Capacity of #10 x 5/8" Grade 2 Screw at Horizontal and Vertical Mullion Va = 2(D)tFu/n Va = (2)(0.190")(0.125")(22,000 psi)/3.0 = 348 lb Capacity of one screw is 130 lb Capacity for Connection with Two Angles is 260 lb Appendix A Revision Log Identification Date Page & Revision Original Issue 12/19/20 Not Applicable