HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance'Method
Project Name: WYNNE THE GRAND CARLTON IMPACT
Builder Name: WYNNE BUILDING COPR.
Street: %5 '��� Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction.or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description ! Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: ! 0.2S4
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1 1445.50 ft2
b. Conservation features
EF: 0.970
b. N/A R= 1 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.47
Glass/Floor Area: 0:098
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and,A
.,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY;
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
--
Lhereby certify.that this building, as designed,, is in compliance
Florida Statutes.
with the Florida Energy Code.
''S➢yr
OWNER/AGJI - ��
BUILDING OFFICIAL:
`
DATE: dd
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified -factory -sealed in accordance with 111403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and,this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
EV'EFOR
[,,F�C� ��--"�
ODCOMPLIA
NCE
TB LUCIE COUNTY
4/211202010:27 AM EnergyGauge® USA! 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)&rriAJ5tSoftware
Page 1 of 5
FORM R405-2017 INPUT SUMMARY' CHF:GKL15T REPORT
PROJECT
i
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: ' 1446
Lot #
Owner Name: WYNNE BUILDING CROP i Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
i Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
i
/
V Design Location
Design Temp
Int Design Temp Heating Design Daily Temp
TMY Site 97.5 % 2.5 %
Winter /Summer
Degree Days
Moisture
Range
FL, Fort Pierce FL VERO_BEACH _MUNI 39 90
70
75 299'
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1446: 1156E
SPACES.
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM
301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2
I,
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No 0
i
1 Yes
.Yes
Yes .
FLOORS
# Floor Type
Space Perimeter. Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
____
0 1
0
2Slab-On-Grade Edge Insulatio
WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
_—_
0, 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
_:__
0 1
0
5 Slab -On -Grade Edge Insulatio
I
'BATH 5 ft 0
45 ft2
_—_
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
___
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
0 1
0
4/21/2020 10:27 AM EnergyGauge® USA'6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT. SUMMARY GHEGKLI5T REPUKI
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area .
Joist R-Value
Tile
Wood Carpet
i
8 Slab -On -Grade Edge Insulatio 'LAUNDRY 6 ft
0
42 ft2
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
/ Roof
Gable
Roof
Rad.
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC.
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
J.
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) W. BATH
30
Blown
56 ft2
0.1
Wood'
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood.
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall,(Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
Space
-
-
1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
j
_ 2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4,
0
3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM
I
4.1 14
0 8
0
112.0 ft2
0.
0
0.4
0
4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
I
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block - Int InsSEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBIEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int InsBIEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9 SW=>NE Exterior Concrete Block - Int'nsINEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
_ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
_ 11 SW=>NE Exterior Concrete Block - Int IInsul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
-12 SW=>NE Exterior Concrete Block - Int lnsuLAUNDRY
4.1 6
0 8
0
48.0 ft2.
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Int ns8REAT/DINT
4.1 26
0. 8
0
208.0 ft2
0
0
0.4
0
=14 NW=>SE Exterior Concrete Block- Int InsL6REAT/DINT
4.1 20.
0 8
0
160.0 ft2
0
0
0.4
0
4/21/2020 10:27 AM EnergyGauge® USA'6'.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing Solar Below
15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2.
i
0.23 0.4
0
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated i ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation. => changed to Worst Case..
Wall
V/ # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area - Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
1.04 0.29 Y 32.9 ft2 1 ft 0 in 1 ft 5 in
1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in
1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in
1.04 0.29 Y 37.5 ft2 1 ft 0 in 1 ft 5 in
1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 815ft2
31�ft2
24ft 8ft
11
i
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
i
1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
SI plit
Singi SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
#. System Type
SubType Location
EF Cap Use SetPnt
Conservation
1 Electric .
None Garage
0.97 50 gal 60:9 gal 120 deg
None
4/21/202010:27 AM EnergyGauge® USA !6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
I
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
!
System
Model #. Collector Model #
Area Volume
FEF
None None
I
ft2
f
DUCTS
/ — supply---
---- Return---
Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
i Location
Area
Leakage Type
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 175 W.
Attic
65 ft2
Default Leakage _
Attic
(Default) (Default)
1 1
I
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan f X� Feb
Mar
Mar
A r
f Apr
May
May
Jun Jul
f Jun' 4 Jul
Auge
4 Au4
Oct
Sep E Oct f X�
Nov.
Nov
Dec
f X� Dec
Ventin Jan . [ l Feb
Mar
[X] Apr
Me
[ Jun [ Jul
[ Aug
[
Se [X] Oct [X]
Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
i
Hours
Schedule Type
1
2 1
3
4
5 6
7
8
9, 10
11
12
Cooling (WD) AM
78
78 !
78
78
78 78.
78
78
80 80
80
80
PM
80
801
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
781
78
78
78 78
78
78
78 78
78
78
PM
78
78.
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM.
66
66,
66
66
:66 68
68
68
68 88
68
68
PM
68
681
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66'
66
66
66 68
68
68
68 68
68
68
PM
68
68�
68
68
68 68
68
68
68 68
66
66
a
MASS.
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
j 0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft?
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
'Defauit(8lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/s .ft.
•ft2
ft
0.3
BEDROOM 3
4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software, Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I TABLE 402.4.1.1
I
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, ' Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
C9
COMPONENT
i
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air.barrier,shall be sealed.
The insulation in any dropped ceiling/soffit
Access openings, drop' down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners -and headers of frame walls
The junction of the top'plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be linstalled at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing cavity
g insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
i
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that.on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
r
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed; in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
fire sprinkler cover latias and�m'm'lls or cellina
a. In addition, inspection of log we shall be in accordance with the provisions of [CC-400.
4/21/2020 10:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017'FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy, Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
r
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number 'of bedrooms
4. 2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case?. (yes/no)
5. Yes
b) Single:package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.. 1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor.(weighted average) 7a'. 1.060
b) Solar Heat Gain Coefficient(SHGC) 7b. 0.284
c) Area i 7c. 141:3
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9.'Floortype, insulation level:
a) Slab -on -grade (R-value)
b) Wood,. raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value),
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly j
c) Knee walls/skylight walls
d) Radiant barrier installed
8a. NA
8b. NA
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
14. Heating system:
Capacity34.8
a) Split system heat pump
HSPF . 8.5.
b) Single package heat pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas
. AFUE
e) Gas furnace, LPG
AFUE
f) Other
1.5. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
-10131.
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
- 19.0
d) Multizone cooling credit .
11d.
No
e) Multizone heating credit
f) Programmable thermostat Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving.features which.will'be installed (or exceeded).in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant -features.
Builder Signature: Date:
�i
Address of New Home:CV S Ql-q-,\�--\. \ City/FL Zip: FT. PIERCE. FL
4/21/2020 10:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1