Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance'Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: %5 '��� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL , Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction.or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description ! Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: ! 0.2S4 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1 1445.50 ft2 b. Conservation features EF: 0.970 b. N/A R= 1 ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 47.47 Glass/Floor Area: 0:098 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and,A ., this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY; Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 -- Lhereby certify.that this building, as designed,, is in compliance Florida Statutes. with the Florida Energy Code. ''S➢yr OWNER/AGJI - �� BUILDING OFFICIAL: ` DATE: dd DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified -factory -sealed in accordance with 111403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and,this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). EV'EFOR [,,F�C� ��--"� ODCOMPLIA NCE TB LUCIE COUNTY 4/211202010:27 AM EnergyGauge® USA! 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017)&rriAJ5tSoftware Page 1 of 5 FORM R405-2017 INPUT SUMMARY' CHF:GKL15T REPORT PROJECT i Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: ' 1446 Lot # Owner Name: WYNNE BUILDING CROP i Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY i Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE i / V Design Location Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5 % 2.5 % Winter /Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH _MUNI 39 90 70 75 299' 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446: 1156E SPACES. Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 I, 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 i 1 Yes .Yes Yes . FLOORS # Floor Type Space Perimeter. Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ____ 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 _—_ 0, 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 _:__ 0 1 0 5 Slab -On -Grade Edge Insulatio I 'BATH 5 ft 0 45 ft2 _—_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ___ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 0 1 0 4/21/2020 10:27 AM EnergyGauge® USA'6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT. SUMMARY GHEGKLI5T REPUKI FLOORS # Floor Type Space Perimeter Perimeter R-Value Area . Joist R-Value Tile Wood Carpet i 8 Slab -On -Grade Edge Insulatio 'LAUNDRY 6 ft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad. Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC. V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented J. 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) W. BATH 30 Blown 56 ft2 0.1 Wood' 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood. 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall,(Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space - - 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 j _ 2 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4, 0 3 NW=>SE Exterior Concrete Block - Int InsuBEDROOM I 4.1 14 0 8 0 112.0 ft2 0. 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH I 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block - Int InsSEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block - Int InsBIEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int InsBIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block - Int'nsINEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 11 SW=>NE Exterior Concrete Block - Int IInsul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 -12 SW=>NE Exterior Concrete Block - Int lnsuLAUNDRY 4.1 6 0 8 0 48.0 ft2. 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int ns8REAT/DINT 4.1 26 0. 8 0 208.0 ft2 0 0 0.4 0 =14 NW=>SE Exterior Concrete Block- Int InsL6REAT/DINT 4.1 20. 0 8 0 160.0 ft2 0 0 0.4 0 4/21/2020 10:27 AM EnergyGauge® USA'6'.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2. i 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated i ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation. => changed to Worst Case.. Wall V/ # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area - Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 Y 32.9 ft2 1 ft 0 in 1 ft 5 in 1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in 1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in 1.04 0.29 Y 37.5 ft2 1 ft 0 in 1 ft 5 in 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 815ft2 31�ft2 24ft 8ft 11 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 i 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ SI plit Singi SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM #. System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric . None Garage 0.97 50 gal 60:9 gal 120 deg None 4/21/202010:27 AM EnergyGauge® USA !6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name ! System Model #. Collector Model # Area Volume FEF None None I ft2 f DUCTS / — supply--- ---- Return--- Air CFM 25 CFM25 HVAC # V # Location R-Value Area i Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 W. Attic 65 ft2 Default Leakage _ Attic (Default) (Default) 1 1 I TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan f X� Feb Mar Mar A r f Apr May May Jun Jul f Jun' 4 Jul Auge 4 Au4 Oct Sep E Oct f X� Nov. Nov Dec f X� Dec Ventin Jan . [ l Feb Mar [X] Apr Me [ Jun [ Jul [ Aug [ Se [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference i Hours Schedule Type 1 2 1 3 4 5 6 7 8 9, 10 11 12 Cooling (WD) AM 78 78 ! 78 78 78 78. 78 78 80 80 80 80 PM 80 801 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 781 78 78 78 78 78 78 78 78 78 78 PM 78 78. 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM. 66 66, 66 66 :66 68 68 68 68 88 68 68 PM 68 681 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66' 66 66 66 68 68 68 68 68 68 68 PM 68 68� 68 68 68 68 68 68 68 68 66 66 a MASS. Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. j 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft? ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 'Defauit(8lbs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/s .ft. •ft2 ft 0.3 BEDROOM 3 4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software, Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I TABLE 402.4.1.1 I AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ' Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce C9 COMPONENT i AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air.barrier,shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop' down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners -and headers of frame walls The junction of the top'plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be linstalled at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing i members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that.on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac r as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed; in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids fire sprinkler cover latias and�m'm'lls or cellina a. In addition, inspection of log we shall be in accordance with the provisions of [CC-400. 4/21/2020 10:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017'FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy, Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level r a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number 'of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case?. (yes/no) 5. Yes b) Single:package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6.. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a'. 1.060 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.284 c) Area i 7c. 141:3 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9.'Floortype, insulation level: a) Slab -on -grade (R-value) b) Wood,. raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value), 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly j c) Knee walls/skylight walls d) Radiant barrier installed 8a. NA 8b. NA 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity34.8 a) Split system heat pump HSPF . 8.5. b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas . AFUE e) Gas furnace, LPG AFUE f) Other 1.5. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other -10131. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. - 19.0 d) Multizone cooling credit . 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving.features which.will'be installed (or exceeded).in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant -features. Builder Signature: Date: �i Address of New Home:CV S Ql-q-,\�--\. \ City/FL Zip: FT. PIERCE. FL 4/21/2020 10:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1