Loading...
HomeMy WebLinkAboutProject Information„ Wrights� Project Siimlinaly Job: : Entire House By - QUICK CALLS, INC. 317 ST. LUCIE LN., Fr..PIERCE, FL 34946 PFore.772-466-6799 Fax 772. 466 6795 Email: QUICKCALCS@AOL.COM For: THE GRAND:CARLTON IMPACT . WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db. 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 . Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heat Coolieg Area (ftz) 1446 1446 Volume (fl3) 12511 12511 Air changes/hour 0.45 0.23 Equiv AVF (cfm) 94 48 Heating -Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A O30 AHRI ref 7914585 Efficiency 8.5 HSPF Heating input Heating output 34600 Btuh @ 47°F Temperature rise 27 OF Actual airflow 1160 cfm Airflowfactor 0.049 Cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh,100 AFUE Summer Design Conditions Outside db 90 OF Inside.db 75 OF Design TD 15 OF Daily range L Relative humidity 50 Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central: vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data In Rate/swin multipplier EquipmeNsensible load 0.95 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none). Equipment latent load 5521 Btuh Equipment Total Load (See+Lat) 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A O30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER cecooling Sen 24360 Btuh Latentcooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Airflowfactor 0.045 cfrn/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 0q//'1�7et8�71F�� 2020-Jan-08162047 RigltSLite@)Urive�sal20l9l9.0.07 RSU08101 r Page 1 iglUoftFNAC1MEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 Frontboorfaces: N -F- wirightww Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name Entire House BEDROOM 2 . E)rosedwall 1562 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/000l 4 5 Room dimensions Room area 1445.5 ft2 ID. x 297.0 It 297.0 tt= Ty Construction number U-value (BtuW-value Or HTM (Btuh/iF) Area or perimeter r (ft) Load (Btuh) Area or perimeter eter (ft) (Btuh) (Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 G 13AAocs 0.143 n 4.00 2.55 563 465 1862 72 72 286 183 =05-2om " " 13A-4ocs 0.770 0.143 n a 21156: 4.00 '19.31 2.55 38 128 0 83 815 333 .1184 730 212 0 0 0 0 0 0 . 0 0 V+l 11 IA-clom 11 DO 1270 0.390 a a 35.56 10.92 8729 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 II_-G D W . Y--G .13A-4ocs 13AAocs 0.143 0.143 . se s -4.00 4.00 -2.55 2.55 34 360 34 353 136. 1414 86 899 0 216 0 216 ..0. 865 0 550 1A-c1om 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 G 13AAocs 1A-b1onn 0.143 1270 " W w 4.00 35.56 2.55 '5521 310 32 237 2 949 1140 603 1770 104 32 : 72 2 288 1140: 183 1770 4A5-2om 12C-0sw 16A-30md 22A fil 0.770 0.091 0.032 0.989 w - - 21.56 2.55 .0.90. 27.69 a i i 19.31 128 2.32 0.00 41. 192 1446 1446 41 192 1446 156 880 489 1295 4325 788 246 3354 0 0 0 .297 297 0 0 297 49 0 0 266 1357 1 0 0 689 0 P C F 6 c) AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 6 1380 3 690 Appliances/other 2000 0 • i Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Lessfransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Ductloads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required (dm) 1160 1160 328 326 Calculations approved WACCAto meet'all requirements of Manual'J 8th Ed. ' �s9>ti 2020-Jan-081620:47 A ""^"^ Right-Sute®Urrversal201919.0.07RSU08101. Pagel ightsoft WAOTHE GRAND CARLTON-1446-IMPACT.rLp Calc=MJB Front Door faces., N I - 1- wrightsoft. Right-J® Work -sheet Job: Entire House Date: QUICK CALLS, INC. By 317 ST. LUCIE LN., Fr.. PIERCE. FL 34946 Phom:772466-679I9 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC KrrCHEN 2 F)posed wall O ft 0 It 3 Room height 8D -ft heat/000l 8D ft heat/000l 4 5 Room dimensions Room area 6D x 9D It 54D T ID x 172.0 It 172.0 ft2 Ty Construction number U-value (Btuh/ft _9 Or HTM (Btuh/IF) Area (ft2) . or perimeter (ft) Load (Bluh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 G ,13A�40cs :4A5 rn, 13A4ocs 0143 0.770 0.143 n .h '. a 4:00 `21.56 4.00 2,55 . 19.31 2.55 0 0, 0 0 .' -.0 0 0 0 0 0 0 0 ,: 0 0 0 0 '0 0 0 0 0, 0. .:' 0. 0 11 1Aclom 11DO 13A4ocs. - 13A4ocs 1270 0.390 0.143 0.143 a a . 'se s 35.56 10.92 .. 4.00 4.00 8729 11.31 2.55 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W. Ud/ 1A-clam 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 —C G 13A4ocs' jXcI60 • 0.143- 1270 w w 4.00 35.56, 2.55 '55.21, 0 -0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 P C ... 4A5-2am . q 12C-09w ;•18 36md .6.7.70 0.091 0.032. w. - - 21.56 2.55 .-0,90. 19.31 128 - -2.32 0. 0 54 0' 0 54 . 0 0 . 48 0 0 125 0 64 172 0 64 172 0 163 154 . 0 82 399 F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 . 0 0 6 c) AED excursion -9 -170 Envelope loselgain 48 117 317 311 12 a) IInfiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants.@ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Lessextemalload 0 0 0 0 14 Lesstansfer Redistribution Subtotal 0 0 48 0 0 117 0 0 317 6 0 2311 15 Dud loads 32% 49% 15 57 32% 49% 100 1126 Total room load Air:required (dm) 64 3 174 8 418 21 3437 153 Wr% Sot11r"' I. .. .. —Q - ► """'!M "^ 'Mgft-Sute®Unversai 201919.0.07 RSU08101 igNsoftHVAMTHEGRAND CARLTON-1446-IMPA IT.np Calc=MJ8 Front boor faces: N 2020-Jan•0816:20:47 Page 2 + wrightsoft- Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phory 772466-6799 Fa)c M 466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BATH BEDROOM2 2 Exposed wall 5.0 It 342 ft 3 Room height 8.0 it heat/cool 8.0 It heaV000l 4 5 Room dimensions Room area 9.0 x 5.0 It 45.0 ft2 1.0 x 203.5 ft 203.5 ftT Ty Construction number U-value (Btuh/fl= °F) Or HTM (Btuhlftz) Area (ft-) or perimeter (ft) Load (Btuh) Area (" or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-40cs 4A5-tom 13AAocs 1Aclom 11DO -13A-4ocs 13AAocs IA-clom 13A4ocs 1Aclom 4A5-2om . 12C-Osv 16A-80md 0.143 0.770 0.143. 1270 0.390 0.143 0.143 1270 0.143. 1270 0.770: 0.091 0.032 n " n .. a a a se s s w w w - 4.00 21:5.6: 4.00 35.56 10.92 4.00 4.00 35.56 4:00 35.86 21.56 2.55 0.90 2.55 19.31 2.55 8729 11.31 2.55 2.55 34.77 2.55 5521 19.31 128 2.32 40 0 0 0 0 0 0 0 0 0 0 0 45 40 0 0 0 0 0 0 0 0 0 0 0 45 160 0 0 0 0 .0 0 0 0 0 0 0 40 102 0 0 0 0 0 0 0 0 0 0 0 104 128 U 80 24 0 34. 32 0 0 0' 0 0 204 128 0 56 2 0 34 32 0 0 0 0 0 204 513 0. 225 848 0 136 128 0 0 0 0 0 182 " 326. -0 143 2082 0 86 81 0 0 0 0 0 472 D W 1I� �--G G P C . F 22A tpl 0.989 27.69 I i i I 0.00 45 5 138 0 204 34 946 0 6 c) AED excursion -16 -85 Envelope losstgain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 1 0 0 13 Internal gains: Oocupants@ 230 0 0 1 230 Applianoss/other 0 0 Subtotal (lines 6 to 13) 425 214 3571. 3498 Lem exemalload 0 0 0 0 Lesstransfer Redistribution 0 0 0 0 0. 0 0 0 14 Subtotal 425 214 3571 3498 15 Ductloads 132% 49% 135 104 32% 49%1 1131 1704 Total room load 560 318 4702 5203 Air required (dm) 28 14 232 232 Calculations approved bvACCA to meet all reauirernents of Manual J 8th Ed. A C Right-Sute®U,ri2020-Jan-081620A7 versal 201919.0.07 RSU08101 Page 3 ightsoftWAC)THEGRAND CARLTON-1446-IMPACInp Calc=MJ8 Front Doorfaoes: N unightsoft" RighWO Worksheet Job. Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr., PIERCE, FL 34946 Phone:772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ' LAUNDRY GREATlDINING 2 Exposed wall 6.0 ft 47D ft 3 Room height 8D It heat/000l 9.8 ft heat/cool 4 Room dimensions 7D x 6D ft 1D x 526.0 It 5 Room area 42D ft' 526D iF Ty Construction U-value Or HTM Area Load number (Btuhdl--°F) (Btuhlft2) or perimeter (ft) (B1uh) oorperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6 VL/G 13A-4ocs " 0.143 n .-4.00 ` 2.55 .0 0 0 - 0 255 - . 217 869 - 552 4A5.2om :" _0.770 -. n- 21'.56: 19.31 0 : 0 0 0 .38 0 ' 815 " "730 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 _ 0 -G IA-c1om 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 1022 11.31 0 0 0 0 0 0 0 0 W,- 93A4ocs 0.143 'se 4.00 '2.55 0 0 0 0 0 0 0 0 VI/ 13A4acs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 �C 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-46m 0.143 w 4.00 2.55 0 0 0 0 206 165 661 420 G IA-c1om 1270 w 35.66 5521 -0 0 0 0 0 0 0 0 4A5.2om . 0.770 w 21.56 19.31 .0. 0 0 .0 41 41 : 880 788 P 12C-Osw 0.091, 2.55 128 56 56 143 72 0 0 0 D C - 16A-30md - OD32 - 0.90 2.32 .42 42 38 - 97 526 - - 526 471 . 1220 F 22A-tpl 0.989 - 27.69 I I 0.00 42 6 166 0 526 47 1302 0 6 c) AED exmrsion -22 668 Envelope lose/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 internal gains: Occupants@ 230 0 0 2 460 Applianceelother 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 LesseMemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 151 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required 42 20 390 338 I. Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -fid- viwrigft cw m 2020-Jan-081620.47 'A °"° ^' .� "' Right Stite®Uriversal 201919.0.07 RSU08101 Page 4 'ZM..igt6soffWAC1THEGRAND CARLTON-1446-IMPACT.4 Calc=MJ8 Front Door faces: N -- wnghtsw Right-J® Worksheet Job:. Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466.6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER M BATH 3 Rheight I7.0 ft 8.0 It heaUcool 8.0 ft 8.0 ft heatt000l 4. 5 Room dimensions Room area. 1.0 x 50.0 It 50.0 ft2 7.0 x 8.0 it 56.0 ft2 Ty Construction number U-value (Bluhl2--°F) Or HTM (BtuhV) Area (112) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Coal Gross NIPS Heat Cool Gross NIPS Heat Cool 6 y! L- G IL-_G 13A flocs .4A5-2om 13A4ocs 0.143 0.770 0.143 . n n a 4.00 21'.56' 4.00 2.55 . - 19:31 2.55 8 0 48 8 0 27 32 0 108 20 :0 69 0 0' 0 0 '0 0 0 .0 0 0. 0 0 11 IA-c1om 11DO 1270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 D W W �G 13A-4ocs 13A-4ocs 0.143 0.143 se . s 4.00 4.00 2.55 2.55 0 0 0 0 0 0 0 0 0 64 0 57 0 228 0 145 IA-c1om 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 G: 13A46cs 1A�1'om 0.143 1270 w, w 4.00 35.56 2.55 65.21 0 0 0 0 0 0 0 0 0 0 0 0 .0. 0 0 0 4A5-2om' 12C-0sN 16A30md 22A tpl 0.770 0.091 0.032 0.989 w 21.56 2.55 0.90 27.69 19.31 1.28 '2.32 0.00 0. 72 50 50 0 72 50 7 0 183 45 194 0 92 116 0 0 0 56 56 0 0 56 8 0 0 50 222 0 0 130 0 P c . F 6 c) AED excursion -39 -38 Envelope losscgaln 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants@ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less ekernal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Ducticada 32% 49% 289 258 32% 49%1 280 251 Total room load 1202 787 1166 768 Air required ckn) 59 35 58 34 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. '* vwrighiSoll�t- 2020-Jan•081620.47 ACCA Right-Sulte® Uriversal 201919.0.07 RSU08101 Page 5 ightsoftWAMTHEGRAND CARLTON-1446-IMPACT.rtp Calc=MJ8 Frontboorfaces: N } vur- tso . Duct System -Summary Date: Entire House BY QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 PhorB: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a AOLCOM For: THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE., FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses _ 0 in H2O 0 in H2O Available static pressure 0.50. in H2O 0.50 in H2O Supply/return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowestf fiction rate 0.285 ih1100ft 0.285 in/100ft Actual airflow 1.160 cfm 1160 cfm Total effective length (TEL) 176 ft SupplyDetail Table Name Design (Btuh) Htg (cim) Clg (dm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (A) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 1t 4 163. 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KrrCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATH'A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Trunk Htg ' Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 0.285 918 12.0 0 x 0 VinIFIX st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinIFIX 2020-Jarl-081620:48 ^' •W�,�9� w � Rigk-Sute®Uriversal 201919.0.07RSU08101 Page 1 ...(gtisoftHVAC1THEGRAND CARLTON-1446-IMPAdT.np CaIc=MJB FrontDoor faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR Veloc (fprh). Diam (in) H x W (in) Stud/Joist _ Opening (in) Duct Mat. Trunk rb1 Ox0 1160 1160 0 0 0 0. Ox 0 VIFx wrightsof - 2020-Jao-0816.0.48 ^'�; aw a•re�emh.« m�rmmnmr Right-StiteO Uriversal 201919.0.07 RSU08101. Page 2 ...IgMsoftWAC1THEGRAND CARLTON-144&IMPACT.np Calc=MJ8 FrontDooriaces: N