HomeMy WebLinkAboutConstruction PlansGround Anchor Installation Instructions 1. Confirm soil classification using standard torque probe at required depth below ground surface, make certain readings meet or exceed required soil class for anchor being installed. 2. Install anchor to its approximate half depth. Install stabilizer plate vertically to its full depth before installing ground anchor to its fullest depth. 3. Pull strap past anchor head and cut strap so that there is 15" of strap. 4. Insert strap into anchor bolt flush with opposite side of bolt. Wrap strap onto tension bolt a minimum of 4-5 turns continuing until anchor shaft is pulled snug against stabilizer plate before tightening hex nut onto tension bolt. NOTE: 60°maximum (Tangle exceeds 60°attach Turn additional strap tie to O LF opposite frame) r'-'t.ss kwise 0 ue probe Install Anchor Wrap strap onto tension Oe h In ordervertically bolt (minimum 4-5 turns) minimum .2 thru 48) WARNING: Do not use torque probe or install anchors until you are certain there are no power lines, phone lines, cable lines, etc. beneath surface or installation area. WARNING: Anchors will not provide adequate wind storm protection unless installed as per installation instructions. NOTE: Local codes, state laws, and federal regulation may vary. Installer is responsible for compliance with all ordinances, codes, laws and other requirements. Frame tie anchor must be stabilized in one of the following ways in order to prevent the anchor from slicing through the soil. Vertical (uplift) anchorage does not require stabilizer plates. Anchors must be installed to their full depth, making certain the ground anchor tension head is flush with ground surface and ground anchor shaft is pulled snug against the stabilizer plate. ATTACHED W/ (4) 8" EXP BOLT ANCHORS TO POST FOOTINGS TYP. Home Approved Stabilizer Plate, shown pre -tensioned PROPER STRAP TENSIONING Step 1 Insert slotted bolt into anchor head, attach loosely. Pull strap past bolt head and cut strap so that 12-15 inches of strap are available to wrap onto the slotted bolt. Step 2 Insert the strap end into the slot in bolt until flush with opposite side of bolt. Step 3 Using 15/16" wrench or socket, turn the bolt, winding the strap so that a minimum of four to five complete turns are made, and the strap is adequately tensioned. Step 4 Hold the bolt under tension while tightening the nut, drawing the head of the bolt into the recess. After the bolt is within the recess, continue to tighten the nut until securely fastened. CERTIFIED GALVANIZED STRAPPING Description Length Part ID: G60 Strap 35 ft. 59150 G60 Strap 37 ft. 59155 G60 Strap 60 ft. 59165 G60 Strap 600 ft. 59170 G120 Strap 37 ft. 59218 G120 Strap 600 ft. 59219 p 12-15 inches Cut step 1 step 3 ' I j(� I step 2 step 4 lax i►\ W LE THICK G-W TIE DOWN ENGINEERING CERTIFIED TO ED PROTECTION ANSI A225.1 ASTM D3953-97 The steel strapping by Tie Down for the manufactured housing industry has been tested to, and conforms to, the HUD Code as referenced in Part 3280 of the Manufactured Home Construction and Safety Standards and Part 3285 of the installation standards; Final Rule. 3280.306(f), 3285.402(b2) Anchoring Equipment - Load Resistance. Anchoring equipment shall be capable of resisting an allowable working load equal to or exceeding 3,150 pounds and shall be capable of withstanding a 50 percent overload (4,725 pounds total) without failure of either the anchoring equipment or the attachment point on the manufactured home. 3280.306(g), 3285.402(b2) Anchoring Equipment - Weatherize Anchoring equipment exposed to weathering shall have a resistance to weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 ounces per square foot of surface coated, and in accordance with the following: (1) Slit or cut edges of zinc -coated steel strapping do not need to be zinc coated. (2) Type 1, Finish B, Grade 1 steel strapping, 1-1/4 inches wide and 0.035 inches in thickness, certified by a registered professional engineer or architect as conforming with ASTM Standard Specification D3953-97, Standard Specification for Strapping, Flat Steel, and Seals. The above specification of a minimum coating of 0.30 ounces per square foot equates to a designation of "G30" Tie Down strapping exceeds this minimum requirement with a coating of 0.60 (G60) or 1.20 (G120) ounces as per above. Similarly, Tie Down strapping exceeds, in testing, the minimum load requirements of 3,150 pounds design (working) load and 4,725 pounds (ultimate) overload. Tie Down Engineering 59155 Certified Galvanized Strapping I G 41tr .[ r-f footings assumed 2500 psi Note 1: See 24 CFR Part 3285 Model Manufactured Home Installation Standards, section 202: Soil Classification and Bearing Capacity & Table 3285.202 for an explanation of soil classification numbers. Please note that anchors approved for use in soil class 4 may be used in soil classes 3 or 2, and anchors approved for use in soil class 3 may be used in soil class 2. In 0 r SET BACK PLAN 4 DEERPARK AVE 72� " �- in Ln 155' PROJECT DESIGN DATA 2/4/2021 JURISDICTION City Fort Pierce CODE FBC 2020 7th Edition Sunjoy Cedar Framed Gazebo PROJECT NAME Steel 2-Tier Hip Roof Hardtop PROJECT ADDRESS 5807 Eastwood Dr Fort Pierce, FL 34951 l WV v I "IN Through metal roof panels into roof frame @12" o.c. ARCHITECT/ENGINEER RISK CATEGORY WIND SPEED ASCE 7-16 (3 Sec Gust) EXPOSURE MEAN BUILDING HEIGHT' 11 160 MPH 130 MPH B <15'-0" Scope of Work: Install Pre -Manufactured 12'x14' Sunjoy Cedar Framed Gazebo Steel 2-Tier Hip Roof Hardtop W/(4) Hurricane Straps @ each corner or Steel Roof ADD#8 TEK screws Through metal roof panels into roof frame @1211 O.C. W/ (4) 12"dia x 24" footings assumed 2500 psi IY For general assembly and connections refer to Manufacturers ASSEMBLY W INSTRUCTION ITEM#: Al02008700 PROPERTY LINE (4) #8 TEK screws into main roof frame (4) Tie Down Engineering 59155 Certified Galvanized Strapping (4) Tie Down Engineering 59135N Slotted Bolt and Nut (4) Tie Down Engineering 5909ON Helix Earth Anchor 5/8" D x 30" L x (1) 4" Helix, Class 2 o(�bs 21 o� " NGE � ��G®MGoe 80GO REVISIONS BY S 17 • Q- Ell EJ In W r In Z 4t Z - D) (r D* V In NW H�� IT I >N�N �+ u J 0 1- -J l� IJ -1 is X FUmvli W E9 U��, m Ww��:l'0 aWa) M I- J o J§oL, �QNa� QI.t. Z M ^ to N a U�LIN W ' O u7 N a M o u_ CU C O CDC a- CU 0 1= U_ ° u 2 L 0 a) N O U 5 y 0 fn LU C � O U) � UJ a L D ZW EqU U in Z Qr- -> W W 17 7r Eli �j W Ul I N W a '�O0 z OZ a U U W U _ 0 0 Li- Q w� U0� U t1 In W U aih J w �� I \�` �2 TP Z DATE 09-21-2020 SCALE DRAWN 09-21-2020 JOB 540SunriseDr SHEET 01 OF SHEETS