Loading...
HomeMy WebLinkAboutBuilding Permit Package All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date : Permit Number: ° w ._ �� Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential xx 2300 Virginia Avenue, Fort Pierce FL 34982 Phone : ( 772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR : Plumbing - water heater change out PROPOSED IMPROVEMENT LOCATION : Address : 113 NE Charleston Oaks DR Property Tax I D #: 3409-601 -0005-000-4 Lot No. 2 Site Plan Name : Block No, Project Name : Wojick DETAILED DESCRIPTION OF WORK: water heater change out New Electrical Meter Second Electrical Meter CONSTRUCTION INFORMATION : Additional work to be performed under this permit — check all that apply: _Mechanical _ Gas Tank Gas Piping _ Shutters _ Windows/Doors _ Pond _ Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq . Ft of Construction : Sq , Ft, of First Floor: Cost of Construction : $ 881 , Utilities : _ Sewer _ Septic Building Height: OWNERAESSEE; CONTRACTOR: NameJoseph W Wojick (TR)Debra A Wojick (TR) Name : Paul Cloutier Address : 113 NE Charleston Oaks DR Company: FPL Home Services City: Port St Lucie State : _ Address: 6001 Village Blvd Zip Code : 34983 Fax: City : west palm beach State : fl Phone No. Zip Code : 33407 Fax: E-Mail : Phone N05615298955 Fill in fee simple Title Holder on next page ( if different E-Mail Desiree. Pacheco@fplhs ,com from the Owner listed above) State or County LicenseCF41430331 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required, If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTA. hCONSTRUCTIONiLIEN LAW INFORMATION ; DESIGNER/ENGINEER : _ Not Applicable MORTGAGE COMPANY : Not Applicable Name : Name : Address : Address : City: State : City : State : _ Zip: Phone Zip : Phone : FEE SIMPLE TITLE HOLDER : _ Not Applicable BONDING COMPANY : _ Not Applicable Name : Name : i Address : Address : City: Clty: ZIP : Phone : Zip: Phone : OWNER/ CONTRACTOR AFFIDVIT: Application Is hereby made to obtain a permit to do the work and Installation as Indicated. I certify that no work or Installation has commenced prior to the Issuance of a permit. St. Lucie County makes no representation that Is granting a permit will authorize the permit holde� to build the subject structure which Is in conflict with any applicable Home Owners Association rules, bylaws or and covenants t mat may resulct or prohibit such structure. Please consult with your Hone Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Not Building Codes and St, Lucie County Amendments, The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessary uses to another non-residential use WARNING TO OWNER : Your failure to Record a Notice of Commencement may result In paying twice for Improvements to your property. A Notice of Commencement must be recorded in the public records of St . Lucle County and posted on the jobsite before the first inspection , If you Intend to obtain financing, consult with lender or a att me before commencingworl< or recordin our Notice of Commencement, Signature o wner/ Lessee contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLOR A r� STATE OF FLORI COUNTY OFcltnn ':1, c(� COUNTYOFE �vno � ea Sworn to (or affirmed) and subscribed before me of Sworn to (or affirmed) and subscribed before me of hysical Presence or Online Notarization Physical Presence or Onllne Notarization this . day of . �AD ,fC�/� 2021l) by �thlfliii day of " Msn 202f by ' Name of person Making statement. Name of person making statement. P otrnQy Known OR Pr duced Identification Pell pe of Id ntlflcation P yKwo_n ._ OR Produced Identification I roduced � (S gnature of Notary Public- State of Florida ) Signature of Notary Public- State o r VZOZt00M.0 s!lldx3 UM ComnnisslonNo, @tca�s� g� eatl �i�rRB,S38S S�Cggge� o°!e°IWuwOgW y. Nolery Public Sla Itgt4fF'slo NO. lie<(y�0g08d V 0811800 +� Desiree A Pach co MY Commla W G 005006 ap!plj Jo 91e1S olWad NetoN OIP xpir I REVIEWS FRONT ZO EGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED i Rev, Michelle Franklin , CFA -- Saint Lucie County Property Appraiser -- All rights reserved . Property Identification Site Address: 113 HE Charleston Oaks DR Use Type: 0100 Sec/Town/Range: 09/36S/40E Account 11: 138605 Parcel ID: 3409-601 -0005-000-4 Map ID: 34/09N Jurisdiction: Saint Lucie County Zoning: RS-2 - Cou Ownership Joseph W Wojick JR) Debra A Wojick (TR) 113 NE Charleston Oaks Or Port St Lucie, FL 34983 i Legal Description CHARLESTON OAKS PHASE TWO LOT 2 (OR 3317- 1750) I Current Values Just/Market Value: $4345600 Assessed Value: $4345600 Exemptions: $50,000 Taxable Value: $384,600 Total Areas Property taxes are subject to change upon change of ownership . Finistred UnderA;r (SF): 3,904 Goss Sketched Area (SF): 7,303 • Past taxes are not a reliable projection of future taxes. Land Size (acres) : 0.93 • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Land Size (SF): 40,510.8 Taxes for this parcel: SLC Tax Collectors Office © Building Design Wind Download TRIM for Ibis parcel: Download PDT p Speed Occupancy Category I 11 III & IV Speed ',. 140 160 ''., 160 Sources/links: All information is believed to be correct at this time, but is subject to change and is provided without any warranty. Copyright 2021 Saint Lucie County Property Appraiser. All rights reserved. n b fPL Home Services Estimate 187245987le 7830 Byron Drive #7 Job 96608139 ( q �"' Riviera Beach, FL 33404 Estimate Date 3/16/2021 Il..,II V l l_.� Customer PO40 ',., Ise I' VlC: GS '.. Billing Address Job . Address Joseph Wojcik Joseph Wojcik 113 Northeast Charleston Oaks Drive 113 Northeast Charleston Port St, Lucie, FL 34983 USA Oaks Drive Port St. Lucie, FL 34983 USA Estimate Details Heater: 50 tall 4500 watt Expansion tank New ball valve Task # Description Quantity Your Price Your Total H010-0001 Callout charge - Includes trip to thejob and diagnostic and is additional to any other 1 .00 $0,00 $0,00 service fee, H057-0063 50 gallon - electric - 50 gallon - electric 1 ,00 $0,00 $0,00 P014- 3/4" BALL VALVE- SWEAT 1 ,00 $ 203,00 $203,00 2245NM P013- EXPANSION TANK 2 GALLON 1 ,00 $ 185,00 $185,00 3170NM Member Savings $36.00 Sub-Total $388,088.00 Tax $0,00 Total $388900 Est. Financing $5.90 Please mail all payments to FPL Home Services 7830 Byron Drive #7 Riviera Beach, FL 33404 By signing this authorization, I also agree to be bound by the governing Terms and Conditions. Credit Card Payment Authorization Please pay total due amount. Thank you. Print Name below as it appears on credit card Payment Type Credit Card # EXP CVC Name on card Signature Remit to: Amount Due: $388,00 7830 Byron Drive 47 Riviera Beach, FL 33404 S m t ® RESIDENTIAL ELECTRIC WATER HEATERS PROLINE ® STANDARD COMMERCIAL- GRADE RESIDENTIAL i ENHANCED HEATING ELEMENTS CODE COMPLIANCE • Dual 4500 watt elements for fast recovery ® Meets UPC and ICC National Codes and and reliable operation ' listed with CEC le � ; • Incoloy stainless steel lower element lasts • Complies with the Federal Energy , �•smnl longer than a standard copper element Conservation Standards effective DYNACLEAN'" DIFFUSER DIP TUBE April 161 2015, in accordance with the Energy Policy and Conservation Act • Helps reduce lime and sediment buildup (EPCA), as amended and maximizes hot water output. Made APPROVED FOR MANUFACTURED from long-lasting PEX cross-linked HOUSING polymer (diffuser design is not used on lowboy models.) • All residential electric water heaters are HIGHER EFFICIENCY compliant with HUD Standards for mobile homes/manufactured housing • Eco-friend) non-CFC foam insulation, heat traps and other features combine to CERTIFIED TO UL FOR HOUSEHOLD HE yield a higher Uniform Energy Factor that ELECTRIC WATER HEATERS maximizes savings on operating costs. CSA CERTIFIED AND ASME RATED T&P COREGARD'" ANODE ROD RELIEFVALVE • Our anode rods have a stainless steel DESIGN-LISTED BY UNDERWRITERS core that extends the life of the anode LABORATORIES - rod allowing superior tank protection far • Certified at 300 psi test pressure and 150 longer than standard anode rods psi working pressure BLUE DIAMOND® GLASS COATING • Listed according to ILL 174 standards • Provides superior corrosion resistance governing storage tank-type electric water compared to industry standard glass heaters lining &YEAR LIMITED TANK AND PARTS ENHANCED-FLOW BRASS DRAIN VALVE WARRANTY • Our residential water heaters have a solid , For complete Information, consult written f brass, tamper resistant, enhanced-flow, warranty or go to hotwateccom ball type, drain valve • Uses a standard female hose fitting that allows for fast and easy draining during maintenance • Designed for easy operation, this valve Includes an integral screwdriver slot that o features a Y4 turn (open/close) radius, which not only permits full straight- — y through water flow but also a quick and positive shut off o GO (YOU Lo e.�dwu © October 2020 A, 0. Smith Corporation. Ail rights reserved. Page 1 of 2 www.hotwater.mm 1800-527-1953 Toll-Free USA I A. 0. Smith Corporation 500 Tennessee Waltz Parkway Ashland City, IN 37015 AOSRE50608 OCO S m hill t ® RESIDENTIAL ELECTRIC WATER HEATERS I Rated First Hour Recovery ® Element Wattage 240V Dimensions in Inches Made" Nominal 90°F Rise Approx. Number Capacity Storaye Rating UEF Gallon Per Shg�pl�lgg ) Volume (Gallons) Hour Standard Minimum Max"Inurn A B C Wel 1t Ibs Tall Models ENT-301- 30 27 48 0,89 21 4500 1000 6000 46-1 /2 39-1/2 79 95 ENT-40t 40 36 53 0,92 21 4500 3500 6000 61 -1 /4 53-114 18 118 ENT-50t 50 46 1 62 0,92 21 4500 3000 6000 59 1 51 -1/4 20- i (2 125 ENT-55t 55 55 72 1 0,93 21 4500 2500 6000 56-1 /2 48-1/2 24 145 Short Models jENS-40uAt SB-30* 30 27 50 0.90 21 4500 1000 6000 39 30-1/2 20 95 S-30t 30 27 47 0.89 21 4500 1000 6000 39-3/4 30-1/2 22 94 S-40t 40 37 55 0,92 21 4500 (4 4500 6000 49-3/4 40-3/4 20- 1/2 109 40 37 41 0,88 ISS-50t 50 46 57 0,92 21 4500 2500 6000 49- 114 40-318 23 161 Lowboy Top Connect Models ENLB-30*t 1 28 1 26 43 0.89 21 4500 1000 6000 30 21 -3/4 20 90 ENL-30t 28 26 44 0.90 21 4500 1000 6000 311 /4 21 -3/4 24 115 ENL-36t 36 33 51 0.92 21 4500 (T500 6000 32 24 24 118 ENL-36Wt 36 33 37 0189 18 1000 4000 32 24 24 118 ENL-4Ot 38 35 50 0.89 21 4500 1000 6000 33 1/2 24 26 118 ENLB-40*t 38 35 51 0,92 21 4500 (8 4500 6000 32 24 23 118 �', ENLB-40W*t 38 35 38 0,90 18 - 1000 4000 32 24 23 118 ENLB-50*t 48 44 60 0,93 21 4500 on 4000 6000 34 25 26- 1 /2 172 ENLB-SOW*t 48 44 40 0.91 16 - 10") 3500 34 25 26-112 172 ENL-SOt 51 48 51 0.92 21 4500 4000 1 6000 1 26- 1/2 172 Male 3/4" water connections on 8" center, *Models ship with supplied Insulation blanket. thor 10 year tank and 10-year parts warranty, change T' to "P" In the model number (example: ENT-30 becomes PNT-30). Models requiring a lower wattage than what Is listed In the minimum wattage column and shoving the ® symbol will change to a "W" suffix model number. "W" suffix models are available down to 110, (example: ENS-40 using 4,000 watt elements or less will become "ENS 40W"), Tap T&P is not available on the 10 year lowboy models and the ENL40. Dimensions and speciiNatlons subject: to change without notice in accordance with our policy of continuous product improvement, j Minimum wattage for ENT-50 Is 3000 watts. T&P VALVE ANODE ACCESS SECOND ANODE ROD FOR LOWBOYS PANEL OR OPTIONAL TOP T&P (All Other Models) 0 0 i i ® C � B A C OO OO JUNCTION BOX ACCESS ° T&P VALVE PANEL DRAIN VALVE i : rt r i October 2020 A. 0. Smith Corporation. All rights reserved. Page 2 of 2 wnvwholwater.com 1800.527-1953 Toll-Free USA I A, 0, Smith Corporation 500 Tennessee Waltz Parkway ( Ashland City, TN 37015 AOSRE50608