HomeMy WebLinkAboutJerryDuckworthShingleA.
�f. �•�
Business & Professional Regulation
r'
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Prodbor
/—,�,�_ if I;' USER:
Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application L > Application Detail
FL # FL30310-R1
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer IKO Industries Ltd
Address/Phone/Email 40 Hansen Road South ,
Brampton, NON -US L6W 3H4 '
(905) 457-2880 Ext4581 '
william.liu@iko.com
Authorized Signature
William Liu
william.liu@iko.com
Technical Representative
William Liu
Address/Phone/Email
40
Hansen Road South
Brampton, FL L6W 3H4
(416) 525-3740
william.liu@iko.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Asphalt Shingles
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
! Validation Checklist - Hardcopy Received
Certificate of Independence FL30310 RI COI IK01900 2 020 FBC Eval hingles final.WE ,
r.. • t .
Referenced Standard and Year (of Standard) Standard
Year
ASTM D 3018 1990 ,
ASTM D 3161 2016
ASTM D 3462 2010
ASTM E 108 2016 A
TAS 100 1995
TAS 107 2020
Equivalence of Product Standards ,
Certified By
s '
A
Sections from the Code
Product Approval Method Method 1 Option D
r.
Date Submitted 10/16/2019 ' !
Date Validated 10/23/2020
Date Pending FBC Approval 10/28/2020
Date Approved 12/16/2020
Summary of Products
FL #
Model, Number or Name
Description
30310.1
IKO Shingles
ASTM D 3161, Class F asphalt shingles, hip and ridge shingles,'
starter strip & shingle strip
Installation Instructions
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL30310 R1 II IKO19002.2 2020 FBC Eval Shingles final.pdf
Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See evaluation report for limits of use.
EL30310 R1 AE IKO19002 2 2020 FBC Eval Shingles final.pLP
Created by Independent Third Party: Yes
r .•'•
0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement -
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The email)s provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please ! provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® Cl
Credit Card
Safe
w.
M lAM "d)E
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NO
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3H4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION. .
11805 SW 26 Street, Room 208,
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599 .
www.miamidade.2ov/economV.
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section '.
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product ,
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Cambridge, Cambridge HD, and Biltmore AR Asphalt Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following '
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change;
in the applicable building code negatively affecting the performance of this product. ;
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for'
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed -
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then'
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.14-0603.02 and consists of pages 1 through 4
The submitted documentation was reviewed by Gaspar J Rodriguez.
4YA-
MLAMI-DADE COUNTY
,,.f
NOA No.: 16-0329.13•.
Expiration Date: 05/05/21
Approval Date: 04/2-1/16 .' ,
Page 1 of 4,
0 . .
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub -Category: Asphalt Shingles
Materials' Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Cambridge AR, Cambridge HD, and Biltmore AR asphalt shingles
manufactured by IKO Industries Ltd. as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions
Test Specifications Product Description
Cambridge 13 3/4" x 40'/8"
TAS 110 A heavy weight, fiberglass reinforced_
Manufacturing Location 41, 2, 3
laminate asphalt shingle. '
Cambridge HD 13 3/4" x 40'/8"
TAS 110 A heavy weight, fiberglass reinforced.4 '
Manufacturing Location 41, 2, 3
laminate asphalt shingle.
Biltmore AR 13 3/4" x 40'/8"
TAS 110 A heavy weight, fiberglass reinforced, '
Manufacturing Location #1, 2
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
2. Wilmington, DE
"
3. Sylacuaga, AL
. .
EVIDENCE SUBMITTED
Test Agency Test Identifier
Test Name/Report Date
PRI Construction Materials Inc. IKO-050-02-01
TAS 100 12/21/09 .
IKO-076-02-01
TAS 100 02/21/12 .
IKO-114-02-01
TAS 100 09/25/14
IKO-099-02-01
TAS 100 05/12/14
IKO-096-02-01
ASTM D 3462 09/27/13
IKO-095-02-01
ASTM D 3462 09/27/13 -
IKO-121-02-01
ASTM D 3462 09/25/14
IKO-100-02-01
ASTM D 3161 (TAS-107) 05/21/14
IKO-115-02-01
ASTM D 3161 (TAS-107) 09/25/14 •
FM Approvals 3041689
ASTM D 3462 02/23/11 r'
•
3036971
ASTM D 3161 (TAS-107) 01/04/09 . " '
3042673
ASTM E 108 04/12/11
•DADE COUNTY
C
NOA No.: 16-0329.13 '
ME ,
Expiration Date: 05/05/21 .
Approval Date: 04/21/16 .
Page 2 of 4 ' '
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft. `
,3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code. i
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached. ,
LABELING roll'
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI•DADE COUNTY I
7#1714 IS
BUILDING PERMIT REQUIREMENTS i
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system. .
MIAMFDADE COUNTY
.�
NOA No.: 16-0329.13 '
Expiration Date: 05/05/11
Approval Date: 04/2iAC
Page 3 of 4
DETAIL A
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR COURSE LAYOUT
—EDGE OF ROOF
-----------------------
24 Note: Roofing Cement not shown in this layout.
_____ This drawing is for course layout only. See Detail B
----- for nailing and cement placement details.
THIRD COURSE
SECOND COURSE
� 4" _T_
i
L -----
9RST COURSE
DETAIL B
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR
40 8"
13 4„
i
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
•
1"
5g7" EXPOSU �
-1 �'*
.. s
NOA No.: 16-0329.13.
Expiration Date: 05/06/21
Approval Date: 04/21/10, .
Page 4 of 4,