HomeMy WebLinkAboutMiami-Dade NOA - 19-0904.01 - RhinoRoof U20MIAMI DA►D .
MIAMI DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RQM) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) w"y.miamidade.gov/econonix
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium® UDL25, Titanium® UDL30, Titanium® UDL50, Titanium® PSU30, RhinoRoor
U10, RhinoRoof U20, RhinoRoof Granulated, RhinoRoofl Metal, TriBuilt, ABC Pro
Guard 20, and SRS TopShield TS20 Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in
its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 19-0305.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Han -ley Pacheco, P.E.
NOA No.: 19-0904.01
Expiration Date: 08/08/23
Approval Date: 01/16/20
Page I of 6
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for Titanium® UDL25, Titanium® UDL30, Titanium® UDL50, Titanium® PSU30,
RhinoRooe U10, RhinoRoof' U20, RhinoRoof® Granulated, RhinoRoof® Metal, TriBuilt, ABC Pro Guard
20, and SRS TopShield TS20 Underlayments as described in this Notice of Acceptance, for use with approved
prepared roof assemblies where ASTM D226 Type II (Titanium® UDL30, Titanium® UDL50, RhinoRoof U10,
RhinoRoof® U20, Titanium® UDL25, ABC Pro Guard 20, SRS TopShield TS20) or ASTM D1970 (RhinoRoof°
Granulated, RhinoRoof�' Metal, and Titanium® PSU30 only) underlayment is specked and installed with prescribed
approved fasteners and fastener densities. Designed to comply with the Florida Building Code including the High
Velocity Hurricane Zone of the Florida. Building Code
PRODUCT DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Titanium UDL25
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
Titanium® UDL-30
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
Titanium® UDL-50
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
RhinoRoof U20
42" x 286' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I and II
sides coated with UV protected and slip resistant
Location 91,2
polymer stabilized polypropylene on both sides.
RhinoRoof U10
42" x 286' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and slip resistant
Location #1,2
polymer stabilized polypropylene on both sides.
RhinoRoof Granulated
36"x65' rolls
ASTM D1970
SBS self -adhering modified asphalt underlayment
Manufacturing
sheet material with a surfacing of opaque
Location #4
granules; for use as an underlayment in sloped
roof assemblies.
NOA No.:19-0904.01
Expiration Date: 08/08/23
Approval Date: 01/16/20
Page 2 of 6
PRODUCT DESCRIPTION:
Test Product
Product Dimensions Specification Description
RhinoRoof Metal 36"x71.3" rolls ASTM D1970 SBS self -adhering asphalt sheet material with a
Manufacturing film facer; for use as an underlayment in sloped
Location #3 roof assemblies
ABC Pro Guard 20
Manufacturing
Location #l,#2
Trilluilt
Manufacturing
Location #1,#2
SRS TopShield TS20
Manufacturing
Location #1,#2
Titanium PSU30
Manufacturing
Location #3
42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I & II sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I & II sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
42" x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I & II sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
36"x72' rolls ASTM D 1970 Unreinforced polymer modified bitumen material
adhered to the underside of a reinforced, polymer -
coated, synthetic woven sheet. The underside is
backed with a release film.
MANUFACTURING LOCATIONS:
1. ML 1
2. ML2
3. ML3
4. ML4
NOA No.:19-0904.01
&piration Date: 08/08/23
Approval Date: 01/16/20
Page 3 of 6
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Intertek Testing Services
311801000Q-003
ASTM D226
02/20/09
3130639COQ-002A
ASTM D226
02/20/08
3146738COQ-003A
ASTM D226
06/20/11
3146739COQ-003B
ASTM D 1876/ TAS 117
03/29/09
100539395COQ-006
ASTM D226
06/02/14
101863861COQ-OOIA
ASTM D226
10/28/14
101823107COQ-011
ASTM D226
12/09/14
PRI Construction Materials
OCF-332-02-01
ASTM D226
05/07/19
Technologies, LLC
OCF-334-02-01
ASTM D226
05/07/19
OCF-331-02-01
ASTM D226
05/07/19
OCF-341-02-01
ASTM D1970
11/28/17
OCF-392-02-02
ASTM D226
08/28/18
OCF-393-02-02
ASTM D226
08/28/18
OCF-394-02-02
ASTM D226
04/15/19
OCF-395-02-02
ASTM D226
04/15/19
OCF-282-02-03
ASTM D 1970
02/19/18
OCF-293-02-02
ASTM D1970
12/28/17
OCF-394-02-07
ASTM D226
04/15/19
OCF-394-02-02.2
ASTM D226
07/29/19
OCF-464-02-02
ASTM D226/TAS 110
12/10/19
APPROVED ASSEMBLIES:
Deck Type 1: Wood
Deck Description: 19/32" or greater plywood or wood plank
System E (1): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
All General and System Limitations shall apply.
Base sheet: One or more plies of ASTM D226, Type R or ASTM D2626 applied with minimum 4" side
laps and minimum 6" vertical laps and mechanically fastened as noted below.
Fastening: Miami -Dade approved nails & metal/tin caps spaced 6"o.c. at the 4" side laps and two
staggered rows 12"o.c. in the field of the sheet.
Membrane: One or more plies of Titanium® PSU-30, self -adhered, with 3" horizontal laps and minimum
6" vertical laps. Place the first course of Titanium® PSU-30 parallel to the eave, using a
heavy pressure roller under safe conditions to further secure the membrane.
Surfacing: Approved for asphalt shingles, metal roofing, wood shakes & shingles, and quarry slate roof
assemblies.
NOA No.: 19-0904.01
Expiration Date: 08/08/23
Approval Date: 01/16/20
Page 4 of 6
INSTALLATION SPECIFICATIONS:
1. Titanium@ UDL30, Tita.nium0 UDL50, RhinoRoof U10, RhinoRoof@ U20, RhirioRoof@ Granulated,
RhinoRoof@ Metal, Titanium@ UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and TitaniumO
PSU30 Underlayments shall be installed in strict compliance with applicable Building Code.
2. Titanium@ UDL30, Titanium@ UDL50, RhinoRoof@ U10, RhinoRoof® U20, RhinoRoof@ Granulated,
RhinoRoof@ Metal, Titanium® UDL25, TriBuih, ABC Pro Guard 20, and SRS TopShield TS20 underlayments
shall be installed with a minimum 4-inch side lap in a shingle layer fashion. Titanium@ PSU30 shall be installed
with a 3-inch side lap in a shingle layer fashion.
3. Titanium@ UDL30, Titanium@ UDL50, RhinoRoofO U10, RhinoRoof@ U20, RhinoRoof@ Granulated,
RhinoRoof@ Metal, Titanium@ UDL25, TriBuilt, ABC Pro Guard 20, and SRS TopShield TS20 underlayments
shall be fastened with Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 1/4" annular ring -shank
nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll.
4. Titanium(g) UDL30, Titamum0 UDL50, RhinoRoof@ U10, RhinoRoof@ U20, RhinoRoof® Granulated,
RhinoRoof@ Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, and SRS TopShield TS20 underlayments
may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing, and quarry slate.
TitaniumO UDL30, Titanium@ UDL50, RhinoRoof@ U10, RhinoRoof@ U20, RhinoRoof@ Granulated,
RhinoRoof@ Metal, Titanium* UDL25, TriBuilt, ABC Pro Guard 20, and SRS TopShield TS20 Synthetic
Underlayments shall not be used as roof file underlayments.
5. For fire classification of specific roof assemblies using Titanium@ UDL30, TitaniumO UDL50, RhinoRoof@
U10, RhinoRoof@ U20, RhinoRoof@ Granulated, RhinoRoof@ Metal, Titanium@ UDL25, TriBuilt, ABC Pro
Guard 20, SRS TopShield TS20 and Titanium@ PSU30 Underlayments, refer to a current Approved Roofing
Materials Directory for fire ratings of this product.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium@ UDL30, Titanium@ UDL50, RhinoRoof@ U10, RhinoRoof@ U20, RhinoRoof@ Granulated,
RhinoRoof@ Metal, Titanium@ UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and TitaniumO
PSU30 underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All
nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
4. Titanium@ UDL30, TitaniumO UDL50, RhinoRoof@ U10, RhinoRoof@ U20, RhinoRoof@ Granulated,
RhinoRooM Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and Titanium@
PSU30 underlayments shall not be hot mopped. Refer to manufacturer's published literature for product
compatibility.
5. Titanium® UDL30, Titanium® UDL50, RhinoRoof@ U10, RhinoRoof@ U20, RhinoRoof® Granulated,
NOA No.: 19-0904.01
Expiration Date: 08/08/23
Approval Date: 01/1.6/20
Page 5 of 6
LIMITATIONS:
RhinoRoof® Metal, Titanium® UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and Titanium®
PSU30 underlayments shall not be applied over an existing roof membrane as a recover system.
6. RhinoRoof® U 10, RhinoRoof® U20, ABC Pro Guard 20, and SRS TopShield TS20 underlayments shall not be
left exposed as a temporary roof for longer than 60 days after application. Titanium® UDL25, Titanium®
UDL30, Titanium® UDL50, and Titanium® PSU30 self -adhering underlayment shall not be left exposed as a
temporary roof for longer than 180 days after application. RhinoRoof® Metal self -adhering underlayment shall
not be left exposed as a temporary roof for longer than 90 days after application. TriBuih and RhinoRoof®
Granulated self -adhering underlayment shall not be left exposed as a temporary roof for longer than 30 days
after application.
7. Titanium® UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titaniumg UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and Titanium®
PSU30 underlayments are components used in roof system assemblies. Roof system assemblies are approved
under a specific Notice of Acceptance. Refer to Prepared Roofing System Product Control Notice of
Acceptance for listed approval of this product with specific prepared roofing products.
8. TitaniumO UDL30, Titanium® UDL50, RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated,
RhinoRoof® Metal, Titanium® UDL25, TriBiult, ABC Pro Guard 20, SRS TopShield TS20 and Titanium®
PSU30 underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium®
UDL30, Titanium® UDL50, RhinoRoofg U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal,
Titanium® UDL25, TriBuilt, ABC Pro Guard 20, SRS TopShield TS20 and Titanium® PSU30 underlayments
as a component part of an assembly in the Notice of Acceptance. If Titanium® UDL30, Titanium® UDL50,
RhinoRoof® U10, RhinoRoof® U20, RhinoRoof® Granulated, RhinoRoof® Metal, TriBuilt, ABC Pro Guard
20, SRS TopShield TS20, Titanium® UDL25, and Titanium® PSU30 underlayments are not listed, a request
may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control
Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
9. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
alt =NT
w_
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 19-0904.01
Expiration Date: 08/08/23
Approval Date: 01/16/20
Page 6 of 6