Loading...
HomeMy WebLinkAboutbldg planFEIC APPROVED PRODUCTS L, , PRODUCT CATEGORY I SUBCATEGORY STRUCTURAL COMPONENTS I ROOF DECK STRUCTURAL COMPONENTS I STRUCTURALWALL LEFT SIDE ELEVATION SCALE: 1/8'=T RIGHT SIDE ELEVATION SCALE: 118' =1' DRILL 5/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH VT DIAMETER THROUGH -BOLT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE EYEANCHOR U 518' ROD 48' LONG WITH 6' HELIX BASE RAIL BASE RAIL ANCHORAGE / Not To Scale MANUFACTURER UNION CORRUGATING COMPANY 26 Gauge MasterRib Panel UNION CORRUGATING COMPANY 26 Gauge MasterRib Panel GENERAL NOTES: RECEIVED SE-1y 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OT14ER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, APPROVAL PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. No. & DATE 2. THESE STRUCTURES ARE DESIGNED AS UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS, IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BEAT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE FL9555.2 RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 06/23/15 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL, ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. FL9555.2 4. FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14x314' SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @6' 06/23/15 O.C.AVERAGE 5. ALL FIELD FRAMING CONNECTIONS SHALL BE#12-14x 314' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALLSHOP FRAMING CONNECTIONS SHALL BE WELDED. 6. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN VOF EVERY POST LOCATION. SEE GROUNDANCHOR DETAIL, DETAIL I, THIS SHEET, FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. Z POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION. 26 GA. GALVANIZED METAL WALL PANELS FASTENED TO POSTS WITH #12A4 x 3/4' SDF's WITH CONTROL SEAL WASHER @ AVERAGE 6.O.C. SPACING 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS WITH #12-14 x 3/4' SDPs WITH CONTROL SEAL WASHER @ AVERAGE 6- O.C. SPACING 2 NIPPLETO RAFTER 24' 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 314' SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) TYPICAL INTERIOR POST/RAFTER SECTION SCALE: 118' =1' 24' 16 GA U-CHANNEL BRACE BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60- FROM HORIZONTAL SECURE POST TO NIPPLE WITH (4) #12-14 x SIT SOPS TS RAFTER POST BOX EAVE RAFTERIPOST DETAIL L Not To Scab IM ` 4171 ST. LUM.. C -? . "T2` BT. II ^T[Kf 1!I EiYe . R.EVIER'EDFOR C A IC'. REVIE ]REVIEWED R DATE 4�__ PLANS AND PERNPT ATUST BE KEPT ON JOB OR NO INSPECTION WI.LL BE MADE. 5' Maximum a , SIDE POST/RAFTER FRAMING PLAN SCALE: 118'=T NIPPLETO BASE RAIL MINIMUM 6' LONG TS NIPPLE SECURE WITH (4) #12-14x 314- SELF-DRILLING FASTENERS POST RAFTER POST/ BASE RAIL CONNECTION DETAIL Not To Scale 2-11T FOR 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14x 31C SELF'DRILLING SCREWS AT EACH END (4 PER BRACE) BRACE SECTION Not TOS.Is OCCUPANCY GROUP: CONSTRUCTION TYPE: RISKCATEGORY: BUILDING ENCLOSURE TYPE: ULTIMATE WIND SPEED (MPH): NOMINAL DESIGN WIND SPEED )MPH): MEAN ROOF HEIGHT (FEET): ROOF ANGLE (DEGREES): DESIGN PRESSURES(PSR: ROOF: WALL: OPEN C 150 116 B.33 14.0 -31.8 -28.6 NOTE: 14 GA FRAMING IS 2-1/2" x 2-1/2" TUBE STEEL ITS). NIPPLES ARE 2-1/4" x 2-1/4" TS FOR 14 GA FRAMING. METAL FRAMING AND SIDING PREFABRICATED BY CARPORTS ANYWHERE P.O. BOX 776 STARKE,FL 32091 THESE ENGINEERING DRAWINGS ARE THE PROPERTY OF BECHTOL ENGINEERING & TE =U1ff1w1ffX9N6, I����A�II INC. THESE DRAWING M HE WRITTEN CONSENT OF INC., AND J&B BUILDING SERVICEMBACTOR OF RECORD THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDt�y��WITH THE REQUIREMENTS OF SECTION 7809 OF THE FLORIDA BOIL�MbliNIBMOIAUEOPROPOSED WORK THE PLANS ARE VALID UNTIL THFRIE SU6d=TMF4WtORRECTIONS• BUILDING CODE. REQUIRED BY FIELD INSPECTORS THAT M ff pA M€gp¢SARY IN ORDER TO BECHTOL Thomas B6chtc Ronda License Y�®NAG v PROPOSED UTILITY STRUCTURE - BUILDING 1 2 1 KEEN ROAD FOIE IBR, # IDA 8nn7 BECHTOL ENGINEERING r RR TS AND TES77MG, I= c NnNa OmrtcNNM a swWaaa. Mn VAn .. M.N.. TB N0i G17002 °xi°'mO1X0'°00m'@ TB SHEET 1 OF 1