HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FORBUILDING CONSTRUCTION
Florida Department of Business.and Professional Regulation - Residential Performance. Method
ProjectName: WYNNE THE WINDSOR IMPACT
BuilderName: WYNNE. DEVELOPMENT
Street: 3`0
PermitOffce: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Newj(From Plans)
9. Wall Types (1432.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208,00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1783.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floorarea above grade (ft2) 1753
b. Knee Wall (Vented)
R=i 9.0 30.00 ft2
Conditioned floor area'belowgrade(ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 6.285
14. Hotwatersystems
a. Electric
Cap:50gal
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970.970
a. Slab -On -Grade Edge Insulation R=0.0 1 1753.00 ft2
b. Conservation features
b. N/A R= 1 ft2
None
c. N/A R= ft2
15..Credits
Pstat
Glass/Floor Area: 0.086 Total, Proposed Modified Loads: 52.17
'PASS
Total Baseline Loads: 53.92
i
Thereby certify that.the plans and specifications covered by
Review of the plans and
"i►
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED 13Y: -
Before construction is completed.
DATE:
this building will be inspected for^
compliance with Section 553.908
_ aA
I hereby certify that this building, as desi ned, is in compliance
Florida Statutes.
'
with the Florida Energy Cody,
OWNER/AGEt4l
BUILDING OFFICIAL:
DATE: XZ�
DATE:
- Compliance requires certification by the air handler unit manufacturer that the is r I'figs as
certified factory -sealed in accordance with R403.3.2.1.�� ai
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in ac a i fQ21 1q%f j ee t requires
an envelope leakage test report wi op kag to 5 01"S &b2� .
Ta LOCI CUI�``
�C
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
' '1
FORM R405-2017 INPUT SUMMARY 'CFIECKLI:ST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
I Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation:' No'
County:
St. Lucie
Jurisdiction:
Whole:House Fan: No
City, State,
Zip:.
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
f CLIMATE
i Design Temp
Site
Int Design Temp Heating Design DailyTemp
DesignL:ocation
TMY 97.5 %
2.5 %
Winter
Summer Degree
Days
Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
- 70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
I
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infif ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 f 288 No
0
1
No .
Yes
Yes
6 BEDROOM 2
180 1440 No
0-
1
1
Yes
Yes
Yes
7 DINING/GREAT.RO
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3.
169 1352 No '
0
1
1
Yes
Yes
Yes
FLOORS
I.
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
-Carpet
1Slab-On-Grade Edge Insulation
MASTER BEDRO 37ft 0
224ft2
____
0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0
3 Slab -On -Grade Edge Insulation
MAST IER BATH 8 ft 0
56 ft2
____
0 1
0
4Slab-On-Grade Edge Insulation
M.LBATH 7ft 0
61ft2
____
0 1
0
5Slab-On-Grade Edge Insulation
LAUDRY 1 ft 0
r
36ft2
____
0 1
0
4/21/2020 10:04 AM
I
f
EnergyGaugeO USA 6:0.02 (Rev.
I
1) - FlaRes2017 FBCBth Edition (2017) Compliant Software Page 2 of 6
FORMR405-2017 INPUT SUMMARY ICHFGKLIST RFPnRT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value Tile Wood
Carpet
0 Slab -On -Grade Edge Insulation
BEDROOM 2 12 ft
0
180 ft2
____
0 1
0
7Slab-On-Grade Edge Insulation
DINING/GREAT 50ft
0
588ft2
--__
0 1
0.
8Slab-On-Grade Edge Insulation
KITCHEN 11 ft
0
209ft2
____
0 1
0
9Slab-On-Grade Edge Insulation
i
BATH 5ft
0
50ft2
_---
0 1
0
10SIab-On-Grade Edge Insulation
i
HALL 1 ft
i
0
25 ft2
--__
0 1
0
11SIab-On-Grade Edge Insulation
FOYER 9 ft
0
92 ft2
____
0 1
0
12SIab-On-Grade Edge Insulation
BEDROOM 3 14 ft
0
169 ft2
'
-___
0 1
0
ROOF
/
Roof
Gable
Roof.
Red
Solar
SA Emitt
Emitt Deck Pitch
�/
# Type Materials i Area
Area
Color .
Barr
Absor.
Tested
Tested Insul. (deg)
1 Hip Metal 1847 ftz
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing-Frac
Truss Type
1 UnderAttic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 UnderAttic(Vented)
WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic(Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic
M. BATH
30
Blown
61 ft2
0.1
Wood
5 UnderAttic(Vented)
LAUDRY
30
Blown
36ft2"
0.1
Wood
6 UnderAttic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 UnderAttic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 UnderAftic(Vented)
BATH
30
Blown
50ft2
0.1
Wood
10 UnderAttic(Vented)
HALL
30
Blown
25ft2
0.1
Wood
11 UnderAttic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 UnderAttic (Vented)
i BEDROOM 3
30
Blown
169 ft2.
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
i
19
Blown
30 ft2
0.11
Wood
C
WALLS
Adjacent
Cavity Width
Space . _
Height
Sheathing Framing Solar
Below
_ 1
f
E Exterior Concrete Block- Int InsuMASTER BE 4.1 16
0 8
0
128.0 ft2
0 0
0.3
0
2
W Exterior Concrete Block- Int InsuMASTER BE 4.1 7
0 8
0
56.0 ft2
0 0
0.3
0
3
. S Exterior Concrete Block- Int InsuMASTEk BE 4.1 14
i
0 8
0
112.0 ft2
0 0
0.3
0
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#
Ornt
,Adjacent Space
To 1AWIT44pp
Cavity Width.
Height
Sheathing Framing
Solar
Below
4
E
Exterior
Concrete Block- Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1 . 12
0
8 0
96.0 ft2
0
0
0.3
'0
7
S
Exterior
Concrete Block- Int InsuDINiNG/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 20
0.
8 0
160.0 ft2
0
0
0.3
0
_ 9
W
Exterior
Concrete Block- Int Insul KITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
'Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_ 11
N
•
Exterior
Concrete Block- Int Insul FOYER
i
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_12
N
Exterior
Concrete Block- Int lnsul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block- Int IrisuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block- Int ln6uBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
N
Garage
Frame - Wood I BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Ornt
DoorType. Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
-WINDOWS
Orientation shown is the entered orientation => chap ed to Worst Case.
/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
'S 3
Metal Low-ESingle Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low -ESingle Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes
1.11 0.27
N
40.0 ft2
8 It 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeillhbArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
i
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 CentralUnit/
Split
Single SEER:15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# . System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
—Supply--
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic
55 ft2 DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan HFeb
HJan
Mar
Mar
Apr
f Apr
Ma Jun Jul
MaYJun Jul
I
Auge
Au
nAug
Sep
Oct Nov
Oct Nov
MNov
Dec
HDec;
Ventin Feb
X Mar
[X] A r
May Jun Jul
Se
[XJ Oct
Dec:
ThermostatSchedule: HERS 2006
Reference
Hours
ScheduleType
1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 78
78 78 78
78
78
78 78 78
78
Cooling(WEH) AM
78
78 78
78 78 78
78
78
78 78 78
78
PM
78
78 78
78 78 78
78
78
78 78 78
78
Heating(WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 .
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68, 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3.
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2 '
Defa ult(8 lbs/sq.ft.
W
ft
0.3
DINING/GREAT RO .
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
4121 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
t-UKM K4U5-1U1 t
INVU I ,UMIVIAKY t;Hr—t:KLIb I
Kl:t UK I
MASS
Mass Type
Area Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2 ft
0.3
BATH
Default(8lbs/sq.ft.
ft2 ft
0.3
HALL
Default(8lbs/sq.ft.
ft2 ft
0.3
FOYER
Default 81bs/s .ft.
ft2 ft
0.3
BEDROOM.3
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
W
Design Location: FL, Fort Pierce
z
y
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous. air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
Y PP 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to,
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the -cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with, the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to. fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind puping and w*r5na-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or,drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in.a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be.used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400:
4/21/2020 10:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
i
2017 EPL DISPLAY CARD
ENERGY PERFORMANCEIEVEL (EPL) DISPLAY.CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient, the home.
1. New home or, addition .
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if-multiple-family)3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no) .
j
5.
Yes
b) Single package . SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC EER
e) Other
7: Windows, type and area
a) U-factor:(weighted average) !
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area j
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single.package heat pump HSPF
8.. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water -heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF.
A. Exterior:
d) Solar system with tank EF
1. Wood •frame (insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value) ;
10131.
11.0
2. Masonry (Insulation R-value) i
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type. and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b). Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier. installed
11d.
No
ej Multizone heating credit
f) Programmable thermostat
Yes
*Label required :by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy
saving features which -will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL
display card will be completed based'on installed code compliant features.
Builder Signature: Date:
Address:of New Home�� ✓� 2.\ City/FL Zip: FT. PIERCE, FL3�� 1
4/21/202010:05:25 AM Ene.rgyGauge® USA 6.0.04 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1