Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FORBUILDING CONSTRUCTION Florida Department of Business.and Professional Regulation - Residential Performance. Method ProjectName: WYNNE THE WINDSOR IMPACT BuilderName: WYNNE. DEVELOPMENT Street: 3`0 PermitOffce: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Newj(From Plans) 9. Wall Types (1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208,00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1783.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floorarea above grade (ft2) 1753 b. Knee Wall (Vented) R=i 9.0 30.00 ft2 Conditioned floor area'belowgrade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 6.285 14. Hotwatersystems a. Electric Cap:50gal 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970.970 a. Slab -On -Grade Edge Insulation R=0.0 1 1753.00 ft2 b. Conservation features b. N/A R= 1 ft2 None c. N/A R= ft2 15..Credits Pstat Glass/Floor Area: 0.086 Total, Proposed Modified Loads: 52.17 'PASS Total Baseline Loads: 53.92 i Thereby certify that.the plans and specifications covered by Review of the plans and "i► this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED 13Y: - Before construction is completed. DATE: this building will be inspected for^ compliance with Section 553.908 _ aA I hereby certify that this building, as desi ned, is in compliance Florida Statutes. ' with the Florida Energy Cody, OWNER/AGEt4l BUILDING OFFICIAL: DATE: XZ� DATE: - Compliance requires certification by the air handler unit manufacturer that the is r I'figs as certified factory -sealed in accordance with R403.3.2.1.�� ai - Compliance requires an Air Barrier and Insulation Inspection. Checklist in ac a i fQ21 1q%f j ee t requires an envelope leakage test report wi op kag to 5 01"S &b2� . Ta LOCI CUI�`` �C 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 ' '1 FORM R405-2017 INPUT SUMMARY 'CFIECKLI:ST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User ConditionedArea: 1753 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 I Worst Case: Yes PlatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 0 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation:' No' County: St. Lucie Jurisdiction: Whole:House Fan: No City, State, Zip:. FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: f CLIMATE i Design Temp Site Int Design Temp Heating Design DailyTemp DesignL:ocation TMY 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 - 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infif ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 f 288 No 0 1 No . Yes Yes 6 BEDROOM 2 180 1440 No 0- 1 1 Yes Yes Yes 7 DINING/GREAT.RO 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3. 169 1352 No ' 0 1 1 Yes Yes Yes FLOORS I. # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood -Carpet 1Slab-On-Grade Edge Insulation MASTER BEDRO 37ft 0 224ft2 ____ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulation MAST IER BATH 8 ft 0 56 ft2 ____ 0 1 0 4Slab-On-Grade Edge Insulation M.LBATH 7ft 0 61ft2 ____ 0 1 0 5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0 r 36ft2 ____ 0 1 0 4/21/2020 10:04 AM I f EnergyGaugeO USA 6:0.02 (Rev. I 1) - FlaRes2017 FBCBth Edition (2017) Compliant Software Page 2 of 6 FORMR405-2017 INPUT SUMMARY ICHFGKLIST RFPnRT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 0 Slab -On -Grade Edge Insulation BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7Slab-On-Grade Edge Insulation DINING/GREAT 50ft 0 588ft2 --__ 0 1 0. 8Slab-On-Grade Edge Insulation KITCHEN 11 ft 0 209ft2 ____ 0 1 0 9Slab-On-Grade Edge Insulation i BATH 5ft 0 50ft2 _--- 0 1 0 10SIab-On-Grade Edge Insulation i HALL 1 ft i 0 25 ft2 --__ 0 1 0 11SIab-On-Grade Edge Insulation FOYER 9 ft 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulation BEDROOM 3 14 ft 0 169 ft2 ' -___ 0 1 0 ROOF / Roof Gable Roof. Red Solar SA Emitt Emitt Deck Pitch �/ # Type Materials i Area Area Color . Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ftz 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing-Frac Truss Type 1 UnderAttic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic M. BATH 30 Blown 61 ft2 0.1 Wood 5 UnderAttic(Vented) LAUDRY 30 Blown 36ft2" 0.1 Wood 6 UnderAttic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 UnderAttic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 UnderAttic(Vented) KITCHEN 30 Blown 209ft2 0.1 Wood 9 UnderAftic(Vented) BATH 30 Blown 50ft2 0.1 Wood 10 UnderAttic(Vented) HALL 30 Blown 25ft2 0.1 Wood 11 UnderAttic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 UnderAttic (Vented) i BEDROOM 3 30 Blown 169 ft2. 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT i 19 Blown 30 ft2 0.11 Wood C WALLS Adjacent Cavity Width Space . _ Height Sheathing Framing Solar Below _ 1 f E Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 2 W Exterior Concrete Block- Int InsuMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 . S Exterior Concrete Block- Int InsuMASTEk BE 4.1 14 i 0 8 0 112.0 ft2 0 0 0.3 0 4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition.(2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Ornt ,Adjacent Space To 1AWIT44pp Cavity Width. Height Sheathing Framing Solar Below 4 E Exterior Concrete Block- Int InsuMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 . 12 0 8 0 96.0 ft2 0 0 0.3 '0 7 S Exterior Concrete Block- Int InsuDINiNG/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 _ 8 W Exterior Concrete Block- Int InsuDINING/GRE 4.1 20 0. 8 0 160.0 ft2 0 0 0.3 0 _ 9 W Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior 'Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 11 N • Exterior Concrete Block- Int Insul FOYER i 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _12 N Exterior Concrete Block- Int lnsul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block- Int IrisuBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block- Int ln6uBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N Garage Frame - Wood I BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Ornt DoorType. Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 -WINDOWS Orientation shown is the entered orientation => chap ed to Worst Case. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 'S 3 Metal Low-ESingle Yes 1.04 0.29 N 32.4 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 2 E 5 Metal Low -ESingle Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 5 in None None 3 E 6 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in None None 4 S 7 Metal Low-ESingle Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-ESingle Yes 1.11 0.27 N 40.0 ft2 8 It 0 in 1 ft 5 in None None 6 W 13 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 GARAGE # FloorArea CeillhbArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 i INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1168.7 64.16 120.66 .0881 5 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # . System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS —Supply-- --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 55 ft2 DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan HFeb HJan Mar Mar Apr f Apr Ma Jun Jul MaYJun Jul I Auge Au nAug Sep Oct Nov Oct Nov MNov Dec HDec; Ventin Feb X Mar [X] A r May Jun Jul Se [XJ Oct Dec: ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 . 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68, 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3. MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 ' Defa ult(8 lbs/sq.ft. W ft 0.3 DINING/GREAT RO . Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN 4121 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 t-UKM K4U5-1U1 t INVU I ,UMIVIAKY t;Hr—t:KLIb I Kl:t UK I MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ft2 ft 0.3 HALL Default(8lbs/sq.ft. ft2 ft 0.3 FOYER Default 81bs/s .ft. ft2 ft 0.3 BEDROOM.3 4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: W Design Location: FL, Fort Pierce z y COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous. air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y PP 9 /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to, unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the -cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with, the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to. fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind puping and w*r5na- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or,drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in.a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be.used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400: 4/21/2020 10:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 i 2017 EPL DISPLAY CARD ENERGY PERFORMANCEIEVEL (EPL) DISPLAY.CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient, the home. 1. New home or, addition . 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if-multiple-family)3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) . j 5. Yes b) Single package . SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7: Windows, type and area a) U-factor:(weighted average) ! 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area j 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single.package heat pump HSPF 8.. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water -heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF. A. Exterior: d) Solar system with tank EF 1. Wood •frame (insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) ; 10131. 11.0 2. Masonry (Insulation R-value) i 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type. and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b). Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier. installed 11d. No ej Multizone heating credit f) Programmable thermostat Yes *Label required :by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy saving features which -will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL display card will be completed based'on installed code compliant features. Builder Signature: Date: Address:of New Home�� ✓� 2.\ City/FL Zip: FT. PIERCE, FL3�� 1 4/21/202010:05:25 AM Ene.rgyGauge® USA 6.0.04 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1