This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2.-0; ON GENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
® IF MULTIPLE PLY. All
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Spanlor less 30' to 60' Span A
so degrees Spree er Bar
1\or 'ess
z _ og �_ Approx 2/3 to ---►
Id/9 Line span approx. Line 1/2 of Span.
REFER TO SCSI REFER TO BCSI
Truss roust be set in's way if crane used. Truss must be set this way if crone used.
cuss is on ekample. ya.r Voss may not Tatch This is an example, truss may not match.
Insist .crane operator sets truss this way. Insist crone operator sets truss this way.
r SEAT PLATES BY CHAMBERS
12
4.00
to
8
cr)
1'
upset=l/4" heel 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
12
4.00 r--
m 0 B�
12—
�4 2 z.00
w
The Architeat's or Architect's repraeent4*iva'b
TRUSSES` FOR TEE FIRST MODEL HCJLD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR T-IAT MODEL. ak®�actorshallromaIi�W� �
"double cheek" of the contraill
The contractor sltaii romalh rocpaRsielo
ARRAN3NE WITH CRANE OPERATOR I ADVANCE FOR A SPREADER BA OF 1 ' 24' IN LENGTH - and
fa► roalcoveiduaeasa►too#sape,
i other construction criteria, A►chilest a
A I approvaloarvur• pan•rairaoP shape,
review of truss strapping, and leading an
® Do not Viand on trusses until they are braced per BCSI properly nailed to straps & hangers structure from gravity ��"p;'®tn�gedaand
— _ — — -- — -- -- 19'-9" 15'-3" I C L l7 4"redcit ° !r dEp I.A.,P.A.
AT
�
O
e
14'-4"
upset=114" heel 15/16" INDICATES LOAD BEARING
PLUMB CUT END REQUIRED BY TRUSSES
SUPPLIED BY BUILDER O
2 x 4 Top Chord AT A HEIGHT OF 8'-0"
WALL HEIGHT 8' ABOVE FINISHED FLOOR
END DETAIL: TYPICAL VAULT
+V1
�_II II�_ III 11" 11 11 11 11�
i I
I
®�®I®I®I®I®I®I11�I�111�®�®�®III®®I®I®►'
_
�rlata►
—_
It
is
COMEMal
INN
assails is
IPA I qk,
is
SIR
`v
1�MIN1
1so1001
®
B.C. INVERTED CENTER x\r WEBS AT
50# POINT LOADS PER TRUSS FOR AIHIU
_�
1®
®
ON
\\\\\,\\\1�10`I�\\`\\i`i\��1\\,��t`la\\\�1`�`\`I
®'®I1I�ItI1I1I�I.I�I�I®I�I®I®I®�®I
I
i' CLOUZSED AIR ARE OF
/ SPECIAL COI`CERN & MUST BE I
CHECKED CAREFULLY & MAY i
t INDICATE DE'IATION FROMPLANS
14'-4"
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Installed Is;
The undersigned acknowledges and agrees:
1; Trusses will be made In strict accordance with this truss placement diagram layout,
which is the sole authority for determiningsuccessful fabrication of the trusses.
2, All dimensions In this layout have been verified by the undersigned,
.3. Unless written notice is provided by certified mall to Chambers Two within tan (10)
days of delivery the undersigned agrees that no baekcharges will be allowed. In the event
such written notice Is furnished Chambers Truss shall have three (3) business days in which
to begin repairs required, or to substitute other trusses, at Chambers optl n.'
4. The undersigned acknowledges receipt of 'BCSI 1-03' summery sheet by 7PI & WTCA,
6. Delivery Is to Job site. It Is the buyeee'responsibility, to make the job alto suitable for
delivery. Chambers Two has the sole authority to determine the suitability of the job site or a
potion of the Job site for delivery. Chambers Truss will be responsible for dump delivery only.
The buyer Is responsible for additlonal delivery expenses If Chambers Truss has to redeliver
because job she Is not prepared for delivery or buyer is not prepared for delivery of trusses,
Buyer Is responsible to Chambers Truss for towing costs duo to site conditions,
e. Price as shown In paragraph 7 below Is subject to change If any changes are. made Ili this layout A $60 per hour fee for revisions may be charged by Chambers Truss. ' ,
7: This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If ntg
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net'
on delivery. Invoice may. be made at scheduled date of delivery it buyer cannot accept
delivery of fabricated trusses. The undersigned agrees to pay Chambom.Truss reasonable
attomey's fee for collectibns in event of payment not timely made. 1.12 %. per month servJee
charge will be added for all sums not paidwithinterms.
8. Signature or Initials anywhere on this sheet constitutes agreement to all terns herein.
- pr In consideration of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and all Indebtedness owed to .
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including attorneys fees, If default In payment for material be made by the
recipient. 1.
10. In the event of any litigation concerning this agreement the Items furnished hereunder
or payments referred to herein, the, parties agree that the sole venue for any such action will
be Saint Lucia County, Florida.
11, Design responsibilities are per "Nallonal Standard And Recommended Guidelines On
Raspondbllitles For Construction Using Metal Plate Connected Wood Trusses
ANSIlIPIM?CA 4 - 2002
DATEp.. _..�
SIGNED
FOR TITLE - ..
Asgeaderbar May beregtitredper"BCSI1.03"t0Milli Nulty &damage.
Multiple ply trusses must be fastened togethor per engineering
before they are set, failure to do so can result In roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the responsibllity of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Tnzstrs must be setand braced per design to proviont injury & damage.
Trusses must be set plumb and square
Do not tat bunks or stack of plywood, roofing material or any
other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
n
3106 Oleander Avenue
FortPlerce, Florida 34982-6423
800-551-5932
Fort Pierce 772 46b-2012 Fax 772 465 6711
Vero Beach 772-569-2012 Stuart 772-2863302 "
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
r Roofing Material Shingle or Shake
>1 Ord. I Loading in PSF Roof R.D.L.
a Top Chord Live 20
C Top Chord Dead 7 4.2
v Bottom Chord Live 10 Non -Concurrent
o c Bottom Chord Dead 10 3
r�l o I TOTAL Load 37 7.2
Duration Factor 115
Wind Speed 165mph
y rn Top Chord C.B. Sheeting by builder.
_ Bottom Chord C.B. Sheeting by builder.
Cj Highest Mean Height 15'-0"
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island NogEVIEWED FOR
Conforms to FBC 2017 �� 2`(IVIpL�ANCE
R.D.L.=Restrainin Dead Load C.B.=Continuous B
Verify DESIGN CRITERIA shown above 1--
building department and your engineer?
Design Criteria is the responsibility of the
Building Desi ner and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: M11392
Scale: 1 /4 = 1'
82 total trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:10/07/15 Revised:03/21/18
v) FOR Revised: 3/05/2020
jigf WYNNE BUILDING CORP.
PORCH1111 DESCRIPTION:
LEFT WINDSOR -7-7d)o IT
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
15 TRUSS DRAWINGS ARE ATTACHED 10 LAYOUT M 11392
3 4, Sly//e� /V i�l
W1 0
MiTek 0
RE: M11392
THE WINDSOR
Site Information:
Customer: Wynne Dev Corp
Lot/Block:
Address: unknown
City: St. Lucie County
r
Project Name: M11392
Model: THE WINDSOR
Subdivision:
State: FL
n
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1 T19781803 A 12/17/2020
2 T19781804 Al 12/17/2020
3 T19781805 A2 12/17/2020
4 T19781806 A3 12/17/2020
5 T19781807 A4 12/17/2020 FILE
6 T19781808 A5 12/17/2020
7 T19781809 ATA 12/17/2020 Copy
8 T19781810 B 12/17/2020
9 T19781811 BHA 12/17/2020
10 T19781812 GRA 12/17/2020
11 T19781813 J1 12/17/2020
12 T19781814 J3 12/17/2020 EEVIEED FOR CC
14 T19781816 J7 12/17/2020 �ODE®INIPLIC1NOG
15 T19781817 KJ7 12/17/2020 ST. L ®CIE COUNTY
This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision ,%011111111111�,,
based on the parameters provided by Chambers Truss. �% p,S A. q i�
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2021. EN
IV
Florida COA: 6634 No 39380
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSlrrPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSIfrPI 1, Chapter 2.
�:• STATE OF •:�Q/
i,4Ss,O N A, 1�0,�
111
Thomas A. Albanl PE No.39380
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 December 17, 2020
1 of 1 Albani, Thomas
Job
Truss
Truss Type
Qly
Ply
THE WINDSOR
T19781603
M11392
A
HIP
1
1
Job Reference o tional
L.namoers I russ, Inc., ron rlerce, rL tf.z4U s mar `J zUZU mi I eK moustnes, Inc. I ue mar z4 l z:o4:Ut euzu rage 7
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXjH_
T1-0 q 6_-10-14 9-0 0 14-111 20-2-13 26-0-0 28-1-2 35-0-0
4-0-0i 6-10-14 2-1-2 5-11-0 5-3 13 5-9-3 2-1-2 6-10-14 -0-0
48 = 2x3 11
4.00 F12
2x3 \\ 4 26 5
3x6 = 4x4 =
6 7.27
4x8 = 2x3
8 g
Scale = 1:60.5
N
A
1 �
d
17 16 15 14 13 12
3x4 — 3x4 =. 3x6 _ 6x8 = 3x4 = 3x6 — 3x4 3x5 —
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.57
BC 0.47
WB 0.94
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/defl L/d
0.42 12-23 >572 240
0.37 12-23 >659 180
0.03 10 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 161 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-5-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0
Max Horz 2=-97(LC 10)
Max Uplift 2=-235(LC 12), 15=1439(LC 12), 10=799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-639/108, 3-4=396/0, 4-5=-9671776, 5-7=967/776, 7-8=-454/938,
8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-15861938, 10-12=-1971/1174
WEBS 3-17=-372/461, 4-17=-272/451, 4-15=1087/1002, 5-15=336/386, 7-14=-766/399,
6-14=-580/997,8-12=-958/447,9-12=358/600, 7-15=-1329/2190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to
13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
This item
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
has been
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Albani, Thomas, PE
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Digital a using DiSi
ususi Di Si
Signature.
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at
Printed copies
this
joint 15 and 799 lb uplift at joint 10.
document are not Considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 14II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Nat
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP11 Quality Criteria, OSS-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781804
M11392
Al
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:08 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of?iF3blfgtYOgDv7Us9cGoCh5CAjz5KiVwkOzzXjGz
1-0- B-6-0 11-0-0 14-9-0 19-8A 24-0-0 27-4-7 35-0-0 6-0-
-0-0 B-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-4-7 7-7-9 -0-0
4.00 12
3x6 =
9ra A
5x6 =
2x3 11
21 5
3x4 =
6 22
13 12
3x5 = 5x8 MT18HS =
2.00 12
5x8 MT18HS =
Scale = 1:61.3
3x12 =
N
Ic?
Ioa
0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in ([cc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL) 0.75 11-12 >563 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
Be 0.91
Vert(CT) -1.21 11-12 >348 180
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.77
Horz(CT) 0.35 9 n/a n/a
BCDL 10.0
Cade FBC2017/rP12014
Matrix -MS
Weight: 155 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 cc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 cc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=3022/2080, 5-6=3022/2080, 6-7=-4643/2994,
7-8=-5324/3364, 8-9=-5751/3700
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=-425/410, 4-13=-354/571, 4-12=362/617, 5-12=-269/279, 6-12=-1034/712,
6-11=-373/892, 7-11=-897/1523, 8-11=404/435
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and'C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This item has been
4) All plates are MT20 plates unless otherwise indicated.
electronically signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Albani, Thomas, PE
6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
Printed copies of this
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface,
document are not considered
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signed and sealed and the
joint 9.
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 8634
8964 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall ee''
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M O ITeRa
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Satety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781805
M11392
A2
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1
ID:_kftGCA6bx7j2Sy1HDXFw7ye3KX-HsZ4SPcOQ8?P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy
r1-0.0 8-6-0 13-0.0 , 14-9-0 22-0-0 27-4-7 35-0-0 3 0- 0
i-0-0' 8-6-0 ' 4-6-0 ' 1-9-0 7-3-0 5-4-7 7-7-9 -0-0
aI1
6
3x6 =
4.00 12
10-0-0
3x4 =
LOADING (psf) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 7.0 Lumber DOL 1.25
BCLL 0.0 Rep Stress Incr YES
BCDL 10.0 Code FBC2017/rP12014
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=825(LC 12)
Max Grav 2=1349(LC 1), 8=1349(LC 1)
5x6 = 3x4 =
4 21 5
12
5x8 =
2.00 12
22
5x8 =
Scale = 1:61.3
3x12 =
CSI. •
DEFL.
in (loc) I/deft L/d
PLATES
GRIP
TC 0.66
Vert(LL)
0.72 10 >585 240
MT20
244/190
BC 0.95
Vert(CT)-0.9410-19 >447 180
MT18HS
244/190
WB 0.86
Horz(CT)
0.34 8 n/a n/a
Matrix -MS
Weight: 160 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=2580/1800, 5-6=-3379/2225, 6-7=5242/3250,
7-8=-5759/3665
BOTCHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441,
8-10=-3410/5485
WEBS 3-13=-420/418,4-13=-427/688,4-12=337/551, 5-12=-777/605, 5-11=-465/925,
6-11=-391/277, 6-1 0=-1 318/2268, 7-10=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and' C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live toads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 8.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 8634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall MiTek'
�L qq�°
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV I� 1T�i k°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSI11nP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Type
Qty
Ply
THE WINDSORT19781806
TSPECIAL
M11392
A3
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:10 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgIdOBS7Gd7NIFvvehhuYXvu2Bsnd9pPr4Rz)gGx
1-0 8-6-0 15-0-0 20-0-0 24 6-8 27 4-7 35-0-0 6-0
8-6-0 6.6-0 5-0-0 4-0-8 2-9-15 7-7-9 -0-0
d
4.00 12
5x6 =
4x5 =
14 13
3x5 = 2x3 II
LOADING (psf)
SPACING-
2-0-0'
TCLL
20.0
Plate Grip DOL
1.25'
TCDL
7.0
Lumber DOL
1.25'
BCLL
0.0
Rep Stress Incr
YES'
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
REACTIONS.
(size) 2=0-8-0, 9=0-8-0
Max Harz 2=-155(LC 10)
Max Uplift 2=-825(LC 12), 9=825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
5x6 =
2.00 12
24-6-8
35-0-0
Scale = 1:62.3
3x12 =
CSI.
DEFL.
in (loc) I/defl Ud
PLATES
GRIP
TC 0.60
Vert(LL)
0.73 11 >572 240
MT20
244/190
BC 0.95
Vert(CT)-0.9711-20
>432 180
MT18HS
244/190
WB 0.83
Horz(CT)
0.36 9 n/a n/a
Matrix -MS
Weight: 160 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 cc purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 cc bracing.
WEBS
1 Row at midpt 7-12
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=2829/1832, 7-8=5320/3257,
8-9=-5720/3554
BOT CHORD 2-14=-1817/3048,13-14=-1817/3048,12-13=-1258/2274,11-12=-2935/5103,
9-11=3302/5445
WEBS 4-14=0/329, 4-13=-897/636, 5-12=316/661, 6-12=-317/616, 7-12=-2727/1643,
7-11 =-1 072/1939, 8-11 =-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VUIt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces S MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
V
A
m
d
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban PE No.39360
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
- - — ---
--
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing �y� iTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 2D601 Tampa, FL 36610
Job
Truss
Type
City
Ply
THE WINDSORT19781807
FSPECIAL
M11392
A4
1
1
Job Reference o lional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:112020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-DEhgt5eexIF7FHyUpcQtEvQjTIDGwGhnOT90duzXjGw
1-0- 8-6-0 14-9-0 17-0-0 8-0- 24-0 8 27-4-7 35-0-0 6-0-
-0 B-6-0 6-3 0 2-3-0 -0- 6 6 8 2-9-15 7-7-9 -0-0
Scale = 1:62.3
�1
6
4.00 12 5x6 = 4x6 =
2x3 11 6 7
16 15 6x10
3x5 = 2X3 II 5x8 = 3x12 zZ
2.00 F12
8-6-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25,
Lumber DOL 1.25
Rep Stress Incr YES
Cade FBC2017/TP12014
CSI.
TC 0.59
BC 0.95
WB 0.98
Matrix -MS
DEFL. in
Vert(LL) 0.80
Vert(CT) -1.05
Horz(CT) 0.39
(loc) I/defl L/d
13 >528 240
13 >400 180
11 n/a n/a
PLATES
MT20
MT18HS
Weight: 172 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP ND.3
WEBS
1 Row at midpt 8-14
REACTIONS. (size) 2=0-8-0, 11=0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=825(LC 12)
Max Grav 2=1349(LC 1). 11=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=2399/1639, 6-7=-2217/1501, 7-8=2380/1519,
8-10=-5361/3228, 10-11=-5716/3480
BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-1 5=-1 117/2168, 13-14=-2920/5154,
11 -1 3=-3232/5441
WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-1631427, 6-14=-309/604,
6-15=-315/409, 8-14=-3146/1901, 8-13=-1034/1946, 10-13=-343/333
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) All plates are MT20 plates unless otherwise indicated.
sealed by Albani, Thomas, PE
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads,
'
using a Digital Signature.
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies Of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 11.
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6034
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall pp��•
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THE WINDSOR
T19781808
M11392
A5
SPECIAL
16
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:13 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6twl SLJKWOV6vFOEp3meVhmzXjGu
Tt-O-Q 8-6.0 14-9-0 17-6-0 24-6-8 27-4-7 35-0-0 _ 36-0-
-0-0 8-6-0 6-3.0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0
Scale = 1:60.3
3x5 =
4.00 12
14 13
2x3 II 5x10 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.81
TCDL
7.0
Lumber DOL
1.25
BC 0.92
BCLL
0.0
Rep Stress Incr
YES
WB 0.74
BCDL
10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD
2x4 SP M 31 'Except•
1-4,8-11:2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS
2x4 SP No.3
REACTIONS.
(size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=825(LC 12)
Max Grav 2=1349(LC 1), 10=1349(LC 1,)
5x8 MT18HS 11
2.00 12
3x12 zz
dm1In
d
DEFL.
in (loc) I/defl Ud
PLATES
GRIP
Vert(LL)
0.8012-13 >526 240
MT20
244/190
Vert(CT) -1.28 12-13 >329 180
MT18HS
244/190
Horz(CT)
0.36 10 n/a n/a
Weight: 160 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS
1 Row at midpt 6-12
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-324712112, 3-5=-244911679, 5-6=2397/1763, 6-7=-5452/3624, 7-9=-5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, i2-13=-1223/2137, 10-12=343115459
WEBS 3-14=0/303, 3-13=861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/388,9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
This item has been
electronically signed and "
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
WARNING - Vedy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5l19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall g�� //:�r
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 'y' iTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/i Duality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781809
M11392
ATA
COMMON
5
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MTek Industries, Inc. Tue Mar 2412:54:14 2020 Page 1
1D:_kfiGCA6bx7j2Syl HDXFw7ye3KK-dpMzW7gWEgdi6lg3UkzarX2EkWJA7jTD4RN3DCzXjGt
r1-0-0 8-4-0 12-11-0 17-0-0 22-10 26.8-0 35-0-0 36-0-0
i-O-O' 84-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0
�1
d
4.00 12
45 =
Scale = 1:59.5
17 '- 15 -- -' 14 '" 12
3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 =
3x8 =
46 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.59
BC 0.68
WB 0.59
Matrix -MS
DEFL. in (loc) Vdefl Lid
Vert(LL) 0.33 14-15 >999 240
Vert(CT) -0.64 14-15 >652 180
Horz(CT) 0.13 10 nla n/a
PLATES GRIP
MT20 244/190
Weight: 166 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-1-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 5-2-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=775(LC 12)
Max Grav 2=1399(LC 1), 10=1399(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=2801/1739, 7-9=2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968, 9-14=-681/524, 6-15=560/968, 3-15=-681/524
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interlor(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
This item has been
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
electronically signed and
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Albani, Thomas, PE
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a DiDial Signature.
Digital
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide
Printed of this
mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift atcopies
joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MI7ek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall MAE
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek`
I
s always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteria, DSS-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
1 N
Icy
d
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781810
M11392
B
COMMON
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:15 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-5OwLjShB?_IZjuFF2SVpOlbSRwk4sA4MJ57cmfzXjGs
r1-0 q 8-3-5 140-0 17 6-0 21-0-0 26 8-11 35-0-0 36 0-0
001 8-3-5 5-8-11 3-6-0 3-6-0 5-8-11 8-3-5
4.00 12
3x6 =
Scale = 1:59.3
1 N
d
3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) -0.11 14-15 >766 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.38
Vert(CT) -0.24 17-20 >715 180
BCLL 0.0
Rep Stress Incr YES
WB 0.63
Hort(CT) 0.03 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 149 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=371(1_C 12), 15=-453(LC 12), 14=-453(LC 12), 10=371(LC
12)
Max Grav All reactions 250lb or less atjoint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 i(lb) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=-1811256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=393/858
WEBS 3-17=-5/301, 3-15=819/591, 5-15=277/325, 7-14=-277/326, 9-14=-819/592,
9-12=-5/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=70ft; L=35ft; eave=5ft; Cat.
11; Exp C: Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Extedor(2) 17-6-0 to
This item has been
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
electronically signed and
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads,
sealed by Albani, Thomas, PE
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Provide
Printed copies of this
mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at
joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10.
document are not Considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33010
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
i
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Duality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601
Tampa, FL 36610
Job
Truss
Type
Qty
Ply
THE WINDSORT19781811
TBOSTON
M11392
BHA
HIP
1
1
Job Reference o tional
o.z4U 5 Mar `d ZUZU MI1 eK Inausines, mc. I ue Mar z4 lz:114:1 t zuzu Page 1
ID_kfiGCA6bx7j2Syl H DXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
15-6-0 21-6-0
r1.0-q 7-a0 , 9-&0 11-6.0 13-aD 1¢0,0 17.6.0 1s-s-o 21-ao 23.6-o z8-6-a 26-0-0 35-0-0 36-o-q
'1-a0' 7-a0 ' 2.6-0 2-0-0 2.0.0 -6- 1�-0 z-a0 2.0.0 1-6-0 2-a0 2-a0 2-6.0 7-0-0 1•a0
Scale = 1:62.4
TOP CHORD MUST BE BRACED BY END JACKS,
ROOF DIAPHRAGM, OR PROPERLY CONNEC 4.00 12 4x4 =
PURLINS AS SPECIFIED.
57 15 58 17
56 12 59
:3x6 2 5 9 20
548 60 22 3x6
5x12 =53 4 6 x6 = 3x4 2,P1 26 5x12
3 11 18 19 1 23 �7
63
14
52
rr
,n 1 2 28 29 N
d Io
35 42 43 34 44 33 45 46 47 48 32 49 31 50 51 30 d
3x6 = 6x8 = 6x8 = 3x6 = 3x4 =
3x4 =
7-0-0 14-0-0 212-0 28-0-0 35-0-0
7-0-6 7-0-0 7-0-0 7-0-0 7-0-0
Plate Offsets (X,Y)— 13:0-6-4,0-1-121,[32:0-3-8 0-3-01
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 2441190
TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a
BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 208 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=179(LC 7)
Max Uplift All uplift 100 lb or less at joints) except 2=565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8),
28=434(LC 8)
Max Grav All reactions 250 lb or less at joint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1),
28=626(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103, 3-4=-1051259, 27-28=1129/710, 3-5=-441/520, 5-7=-436/514,
7-10=-436/514, 10-11=-436/514, 11-13=-436/514, 13-16=436/514,16.18=436/514,
18-19=-436/514, 19-21=382/412, 21-23=-382/412, 23-25=-382/412, 25-27=387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=575/1004, 28-30=-568/1039
WEBS 3-35=1911649, 27-30=0/451, 3-33=-2090/1523, 11-33=810/782, 19-32=-772/745,
27-32=-1484/1044, 9-10=-463/453, 20-21=-462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb
down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-11-4, and 158 lb down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69
lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4. 69 lb down at 21-114. 69 lb down at 23-11-4. and 69 lb down at 25-11-4. and 69 lb down at 27-11-4 nn hnttnm nhnrd
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 60M
8904 Parke East Blvd. Tampa FL 33610
Date:
T1f—e ciesign/selection of sucn connection ewce s Is the respond I I y o o ers.
® d�xk eVe9Pd3sCA�E(ts)�emtiorffAaac�repptied to kue�faca t6leitr saB�t9 �mmb(Fi� mn.tfattl2ABEFORE USE.
DEi19fffly MTek®connectors. This tlesign is based ony upon parameters shown, antl is for an individual building component, not
a,"
trp�r sB7bltyj(dylg designer must verify the applicability of design parameters and properly incorporate this design into the overall
bui dditional temporary and permanent bracingMiTek
lwairr general guidance regarding thefabrage, delivery, erection and bracing of trusses and truss systems, see ANSI/fPl1 Duality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Sude 203 Waldod, MD 20601 Tampa, FL 36610
March 24,2020
Job
Truss
TypeQty
Ply
THEWINDSORT19781811
FBOSTON
M11392
BHA
HIP
1
1
Job Reference (optional)
unamoers i russ, Inc., Fort tierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:17 2020 Page 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb7HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 36-39=20, 1-3=54, 3-15=-54, 15-27=-54, 27-29=54
Concentrated Loads (lb)
Vert: 35=-373(F) 30=23(F) 42=-23(F) 43=-23(F) 44=-23(F) 45=23(F) 46=-23(F) 47=-23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F)
54=-118(F) 55=118(F) 56=118(F) 57=-118(F) 58=-118(F) 59=118(F) 60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F)
--- - --- — --............... -
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTekD connectors. This design Is based only upon parameters shown, and is for an individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall `•��a
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUfP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty .
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX=nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvQzxjGo
T1-0-q 14-11-0 21-5-2 28 0-0 35-0-0 36 0-Q
i-0-0' 7-0-0 ' 7-11-0 6-6-2 6V; 7-0-0 -0-0
Scale = 1:60.3
5x12 MT18HS =
4.00 12
3 22 , 23 24 25
�1
d
3x4 = 2x3 II
3x5 II 3x6 = 4x8 =
4 26 27
4x8 =
28 629 30 31 32 7
JJ J4 1Y JJ JO J/ JO Jy -11 9u 41
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3 `Except'
4-13: 2x6 SP No.2
3x6 =
5x14 =
3x4 = 4x6 = 2x3 11
3x5 =
CSI.
DEFL.
in floc) Udefl L/d
PLATES
GRIP
TC 0.94
Vert(LL)
0.3010-21 >792 240
MT20
244/190
BC 0.67
Vert(CT) -0.30 10-12 >B12 180
MT18HS
244/190
WB 1.00
Horz(CT)
0.09 8 n/a n/a
Matrix -MS
Weight: 153 lb
FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 4-6-8 oc bracing.
WEBS
1 Row at midpt 6-13
2 Rows at 113 pts 3-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-448(LC 8), 13=2442(1_13 8), 8=1159(LC 8)
Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3-4=-1052/1347, 4-6=-1'05211347, 6-7=-1946/1834, 7-8=-2978/2565
BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=489/690
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
joint 13 and 1159 Ito uplift at joint 8.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
7-0-0. 90 Ito down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 Ito down and 155 lb up at 13-0-12, 90 lb down
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 Ito down and 155 lb up at 17-11-4, 90 Ito down and 155 lb up at
19-11-4. 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and
203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 Ito down and 3 lb up at 9-0-12, 63 lb
down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4. 63 lb down and 3 lb up at 21-11-4, 63 lb down and
3 Ito up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 Ito down and 263 lb up at 27-11-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
tt
N
Ic
d
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature:
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
Walk USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8).
® IcrSA&CASEJ%sl�taerdardrs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Dis(9ftffAVVUrgVd _dLw MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a Wss system. of re se, he building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�e
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSb7PI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
March 94 7n9n
Job
Truss
Truss Type
Ply
THE WINDSOR
T19781812
M11392
GRA
]Qty
HIP
1
1
Job Reference o tional
Cnamoers I russ, Inc., t-ort v erce, I-L
6.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX=nAsZgkf3CG_CWZOHIZIYbI7yXOVouLyEj5gvQzXjGo
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25„Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=54, 3-7=54, 7-9=54, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-147(B) 7=147(131) 15=-452(B) 13=-40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=90(B) 27=90(1]1) 28=-90(B) 30=-90(B) 31=90(13)
32=-90(B) 33=-40(B) 34=-40(B) 35=40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-40(B) 40=-40(B) 41=-40(B)
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. '
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ISE
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek`
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP/1 Duality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781813
M11392
J1
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX_nAsZgkf3CG_CWZOHIZIYblBwXAho7vyEj5gvQzXjGo
-1-0-0 1-0-0
1-0-0 1-0-0
3x4 =
Scale = 1:6.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
5 >999 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=-140(LC 12)
Max Grav 3=11(LC 17).2=118(LC 1),4=17(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall,
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
uss Type
City
Ply
THE WINDSOR
]MONO
T19781814
M11392
J3
TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:20 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq?4_5olMZxUHXa95SNgNRszXjGn
1-0 0 3-0-0
3-0-0
3x4 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25,
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017n-PI2014
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=147(LC 12), 4=-4(LC 12)
Max Grav 3=64(LC 1). 2=173(LC 1), 4=50(LC 3)
Scale = 1:9.4
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TC 0.18
Vert(LL) 0.01
4-7 >999 240
MT20 2441190
BC 0.19
Vert(CT) -0.01
4-7 >999 180
WB 0.00
Horz(CT) -0.00
3 n/a n/a
Matrix -MP
Weight: 11 lb FT = 0%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use anly wfth MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�®
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall'
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781815
M11392
J5
MONO TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
-1-0-0
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:212020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYG1 PFh1 awzlzXjGm
5-0-0
5-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Vdefl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.73
Vert(LL)
0.07
4-7
>863
240
TCDL 7.0
Lumber DOL
1.25
BC 0.70
Vert(CT)
-0.06
4-7
>964
180
BCLL 0.0
Rep Stress Incr
YES,
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014 '
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=177(LC 12). 4=-9(LC 12)
Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250'(Ib) or less except when shown.
Scale = 1:12.7
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39360
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33910
Data:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. --
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall INV @'
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, 6904 Parke Blvd.
East East
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781816
M11392
J7
MONO TRUSS
24
1
Job Reference (optional)
Chambers.Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:21 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WivbgWiRpjPOibDeOrSnKmPG1 PFh1 awzlzXjGm
1 0 0 7-0.0
1-0-0 7-0-0
Scale: 3/4"=l'
3x4 =
700
7-M
Plate Offsets (X,Y)— 12:0-1-14,Edgej
LOADING (psi)
SPACING- 2-0-0
CS].
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) 0.17
4-7 >494 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.19
4-7 >447 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=161(LC 12)
Max Uplift 3=-153(LC 12). 2=-211(LC 12), 4=-12(LC 12)
Max Gram 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE N0938d
MiTek USA, Inc. FL Cert'6034
6904 Parke East Blvd, Tampa FL 33610
Date:
March 24,2020
WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with Mffek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design into the overall t
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing.of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
THEWINDSOR
T19781817
M11392
KJ7
MONO TRUSS
4
1
Job Reference (optional)
unamoers I russ, Inc., Hon Hlerce, hL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-OMr_BsmXM7eZ3zlbyQ7SADNhnk9g?RvOwhJUWIZXjGI
1 5 0 6-8-12 9-10-1
1-5-0 6-8-12 i 3-1-5
Scale = 1:20.6
3x4 = zxa n 5
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.20
Vert(LL)
-0.04
7-10
>999
240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.26
Vert(CT)
-0.08
7-10
>999
180
BCLL 0.0
Rep Stress Incr NO
WB 0.24
Horz(CT)
0.01
5
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014 -
Matrix -MS
Weight: 38 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical
Max Horz 2=192(LC 8)
Max Uplift 4=131(LC 8), 2=262(LC 8), 5=-238(LC 8)
Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250, (lb) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=-487/798, 6-7=-487/798
WEBS 3-7=0/307, 3-6=920/561
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, 6=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)40-5=49(F=15, B=-15)
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.89380
MiTek USA, Inc. FL Cart 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/1912020 BEFORE USE. °
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPlf quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-11fi r
am
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
`Plate location details available in MiTek 20/20
software or upon request
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2 3
TOP CHORDS
0
of
O
2
U
IL
O
I-_
8 7 6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise "shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
III )♦
M!Tek S
MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSIrrPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSlrrPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or puriins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSIrrPI 1 Quality Criteria.
21.The design does not take into account any dynamic
or other loads other than those expressly stated.