Loading...
HomeMy WebLinkAboutAPPROVED FL5259 TU PLUS 1120/2021 Florida Building Code Online NNLW Professional Regulation r r ! BCIs Home f Log In I User Registration I Hot Topics ! Submit surcharge { Stats&Facts Publications I Contact Us BCIS Site Map E Links i Search � 'da �, r Product Approval r USER;Public User Product Approval Menu>Product or.Application 5earcb>Application List>Application Detaif FL# FL5259-R31 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 maIpert@j)c)lyglass.com Authorized Signature Maury Alpert malpert@polyglass com Technical Representative TECH REP Jl Address/Phone/Email illl West Newport Center Drive r� Deerfield Beach, FL 33442 tlspolyglasstechnical@polyglass.com { ray Quality Assurance Representative QA REP • Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical@polyglass.corn Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By ]ohn W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL5259 R31 COI 2020 01 COI NIEMINEN lLdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM Db222 2011 ASTM D6509 2015 https:/Iflorida build"ing.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegDlip3cPzPSPEkchxoaj6Vjg 1%2bg%3d%3d 1/2 1/2012021 Florida Building Code Online FM 4474 2011 FRSA/TRI,Sixth Edition 2018 UL1897 2015 Equivalence of Product Standards Certified By Sections from the Cade Product Approval Method Method 1 Option D Date Submitted 10/22/2020 Date Validated 10/26/2020 Date Pending FBC Approval 11/01/2020 Date Approved 12/15/2020 Date Revised 12/21/2020 Summary of Products FL# Model,Number or Description Name 5259.1 Polygiass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R31 II 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS F1_5259- Approved for use outside HVHZ:Yes 931.pdf Impact Resistant:NIA Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party:Yes Other; 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R31 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- underlayment system for use in tile roof R31.pdf systems. Refer to ER Section 5.8.3 for other Created by Independent Third Party:Yes systems and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Nest Contact US::2601 Blair Stone Road,Tallahassee Ft 32399 Phone:850-487-1824 The State of Florida is an AA/EEo employer.Cop ririighr 2007-2013 SYBte of Florida.::Privacy Statement::Accessibilitm5,tatement::Refund Statement under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F,S.,please dick here. Product Approval Accepts: ®® ® R Credit Card Safe https:lifloridebuilding.orgiprlpr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg0iip3cPzPSPEkchxoaj6Vjgl%2bg%n3d%3d 212 NEM01 etc. Certificate of Authorization 432455 353 Christian Street, Unit#13 04 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION Polyglass USA,Inc. Evaluation Report P12060.02.09-R27 1111 West Newport Center Drive FL5259-R31 Deerfield Beach, FL 33442 Date of Issuance:02/24/2009 (954)233-133D Revision 27:09/30/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7"Edition (2020)Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 17. Prepared by: 4.•�PS.F„4 ate:fi:4 :z Robert J.M.Nieminen,P.E. Florida Registration No.59166,Florida DCA ANE1983 The facsimile seal appearing was authorized 6y Robert Nieminen,P.E.on 09/30/20ZO.This does not serve as an eiectronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issues- 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5, This is a building code evaluation, Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC ONEMOJetc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underiayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 711 Edition (2020) Florida Building Code through testing in accordance with the fallowing Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3A Wind resistance UL 1897 2015 1507.1.1/R905.1.1 Material standard ASTM D226 2009 1507.1.1,1507.2.4,1507.2.9.2 J Material standard ASTM D1970 2015 R905.1.1,R905.2.8.2 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2028 1507.11.2/R905.11.2 Material standard ASTM D6163 2015 1507.11.2/R905.11.2 Material standard ASTM D6164 2011 1507.11.2/R905.11.2 Material standard ASTM D6222 2011 1507.11.2/R905.11.2 Material standard ASTM D6509 201-S TAS 110 Accelerated Weathering ASTM D4798 2011 gntilt Examination Reference Date Enti Examination Reference bate ERD(TST 60491 Wind Uplift 11757.09.01-1 08/13/2001 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 PLYG-SC12115,08.17 08/08/2017 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) TAS 103 PLYG-SC13035,08.17 10/31/2017 ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 FM(TST 1867) Wind Uplift 3004091 D1/12/2000 ERD(TST 60491 Wind Uplift P9260.03.08 03/21/2008 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019 ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 M-D(CER 1592) HVHZ Compliance NOA 17-0614,22 07/06/2017 ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 MT!(TST 2508) ASTM D4798 JX20H7A 04/01/2008 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 NEMO(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018 ERD(TST 6049) ASTM D4977 P11030,11.09-3 11/30/2009 NEMO(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 ERD(TST 6049) ASTM D1970 P33360,06.10 06/25/2010 NEMO(TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019 ERD{TST 6049) TAS 103 P33370.03.11 03/02/2011 NEMO(TST 6049) ASTM D6222 4S-P1_YG-18-D02.05.19-C 6S/20/2019 ERD(TST 6049) Tensile Adhesion P33370.04.11 a4/26/2011 NEMO(TST 6049) ASTM 01970 4j-PLYG-19-55UDL-00.A 09/10/2019 ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 NEMO(TST 6049) TA5103 45-PLYG-18-004.10.19-G 10/08/2019 ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 NEMO(TST 6049) TA5103 4S-PLYG-18-004.10.19-1 10/09/2019 ERD(TST 6049) Tensile Adhesion P40390.08.12 2 08/07/2017 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/09/2019 ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-01.A 10/10/2019 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-D04.12.19-F 12/18/2019 ERD(TST 6049) ASTM D197G P45370.04.13 04/26/2013 NEMO(TST 6049) TAS 103 4j-PLYG-19-55UDL-02.A 01/02/2020 ERD{TST 6049) Wind Uplift P1738.02.07-R2 04/29J2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20,H 01/14/2020 ERD(TST 6049) Wind Upiift 11757.04.01-1-Ri 04/30/2013 NEMO(TST 6049) ASTM D1970 45-PLYG-18-004.01.20.K 01/14/2020 ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/7013 NEMO(TST 6049) TA5 103 4S-PLYG-18-004.01.20.A 01/16/2920 ERD(TST 6049) ASTM D6509 P37590.03.13-1-R1 06/26/2013 NEMO(TST 6049) ASTM D6164 45-PLYG-18-004.01.20.8 01/16/2020 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO(TST 6049) ASTM 06222 45-PLYG-18-002.12.19-K-Rl 01/07/2020 ERD(TST 6049) ASTM D46D1 P45940.09,13 09/04/7013 NEMO(TST 6049) TAS 103 PLYG-SC15855.05.20.A 05/29/2020 ERD(TST 6049) Wind Uplift P11751.05.03-131 11/26/2013 NEMO(TST 6049) TAS 103 4j-PLYG-20 SSUDL-01 07/06/2020 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/25/2013 NEMO(TST 6049) ASTM D6222 4q-PLYG-I9-SSMBR-05.A 07/23/2020 ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 MEMO(TST 6049) ASTM D4798/D1623 4j-PLYG-I9-SSUDL-05.A 09/10/2020 ERD(TST 5049) Tensile adhesion 6020.09.14-5 09/08/2014 N E M 0(TST 6049) ASTM D1970 4j-PLYG-20-SSU0L-05.A 09/30/2020 ERD(T5T 6049) Tensile adhesion 6020.09.14-6 09/08/2014 NEMO(TST 6D491 TA5103 4j-PLYG-20-55UDL-05.0 09/30/2020 ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 NEM0(TST 6049) TAS 103 4j-PLYG-20-SSUDL-11 09/30/2020 NEMO ETC,LLC. Evaluation Report P12060.02.09-R27 Certificate of Authorizotlon#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 2 of 17 ONEMOjetc. Entity Examination Reference Date gntint Examination Reference Date ERD(TST 6049) ASTM D1970/D4798 P43290.1014 10/17/2014 PRI(TST 5878) Tensile Adhesion PR101111 04/08/2002 ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 PRI`(TST 5878) TAS 103 PUSA-018-02-01 07/14/2003 ERD(TST 6049) Tensile adhesion 1340390.04A5 04/031201S PRI(TST 5878) TAS 103 PUSA-035-02-01 09/29/2006 ERD(TST 6049) TAS 103 P44360.10A4-R1 05/18/2015 PRI(TST 5878) TAS 103 PUSA-055-02-02 12/10/2007 ERD(T5T 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 PRI ITST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008 ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16 1 06/271201.6 PRI(TST 5878) ASTM D6164 PUSA-088-02-01 07/29/2009 ERD{TST 6049) Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 ERA(T5T 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016 Polyglass USA Materials Affidavit Polystick Compound 08/18/2021 ERD{TST 6049) ASTM 1)1970/04798 PLYG-SC8080.07.16 07/16/2016 UL(QUA9625) Quality Control Service Confirmation(FL) 09/13/2018 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 UL(QUA9625) Quality Control Service Confirmation(Tx) 11/07/2019 ERD(TST 6049) TAS 103 PLYG-SC13040.12.16 12/27/2016 UL(QUA96251 Quality Control Florida BCIS Current PRODUCT4. i • Product Material Standard Plant(s) Description 4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet 4.3 Elastoflex S6 G ASTM D6164 FL,PA Po)yester-reinforced,SBS modified bitumen cap sheet FRSA/TRI09-18 4-4 Eiastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TR109-18 4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.7 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSAITRI09-18 4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet (FR) FRSA/TR109-18 4.9 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the "Two Ply System"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition beneath mechanically fastened or adhered tile roof systems 4.10 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the "Two Ply System"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition beneath mechanical€y fastened the roof systems 4,11 Polyflex SA P ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI 09-18 4.12 Polyflex SA P FR ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet FRSA/TR109-18 4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet 4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet NEW ETC,LLC. Evaluation Report 1712060,02.09-1127 Certifrcate of Authorization#32455 7F EDiTION(2020)f8C NON-HVH2 EVALUATION f1.5259-1131 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 3 of 17 ON EMO I etc. 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.15 Polystick IR-Xe ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface 4,16 Polystick MTS Plus ASTM D1970 FL,NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with poiyolefinic film surface 4.17 Polystick MU-X ASTM D19701 FL,NV,PA Nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polypropylene film surface 4.18 Polystick TU Max ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/mz polyester fabric surface 4.19 Polystick TU P FRSA/TRI 09-18 FL,PA,TX Nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced,with a granular surface 4.20 Polystick TU Plus ASTM D1970 FL,PA,TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane,glass fiber reinforced,with a polyester fabric surface 4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with a textured film surface 5.1 This is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 55 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 1 Polystick MU X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM 01970-I5,shouid be established as to slip resistance. NEMO ETC,LLC, Evaluation Report P12060.02.09-1127 Certificate of Authorization#32455 7T"EDITION(7-020)FBC NON-HVHZ EVALUATION FL5259-1131 Polyglass Roof Underiayments Revision 27.1 09/30/2020 Page 4 of 17 ONEMOjetc. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt Clay and Concrete Tile Metal Slate or P Woad Underlayment Shingles (1507.3) Slate-Type (1507.2) Mechanical Adhesive- Panels Shingles Shingles Shingles Attach Set (150Z4) (1507.5) (150Z7) (1507.8) Shakes(I507.9) Yes Yes Yes Yes Yes Yes Yes Yes Elastobase (Aiternateto (as Base sheet, {as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to D226, (Alternate to 0226, D228,Type Ti) See 5.8.3) See 5.8.3) D226,Type I I) 0226,Type II) ❑226,Type ItJ Type II) Type 11) Yes Yes Yes Yes Yes Yes Yes Yes Elastobase P (Mernateto {as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to p226, (Alternate to 0226, D226,Type II) See 5.8.3) See 5.8.3) D226,Type EI) D226,Type 11) D226,Type fl) Type II) Type Il) Yes Yes Pol lass B No y� Base {as Base Sheet, (as Base Sheet, No NO No NO NO See 5.8.3) See 5.8.3) Yes Yes Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No No No See 5.8.3) See 5.8.3) Elastoflex 56 G No Yes Yes No No No No No (See 5.6.11 Elasto€lex 56 G FR No Yes No No No No No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes u8int strips,1507.1.1.3 Goint strips,1507.1.1.3 (R905.1.1,33 /R905.1.1.3) Yes Yes Yes HydraGuard Tile Pro Yes Yes yes Yes Yes (See 5.6.1) (joint strips,1507,1.1.3 (joint strips,2507.1.1.3 /R9a5..1.L3) /R905.1.1.31 Mule-Hide SA-APP Cap Sheet No Yes Yes No No No No No {see s.s.1} Mule-Hide SA-APP Cap Sheet(FR) No Yes Yes(See 5 6.1) No No No No No Polyflex G No Yes Yes No No No No No (See 5.6.1) Polyflex G FR No Yes No No No No No No Polyflex SA P No Yes Yes No No No No No (See 5.6.1) Polyflex SA P FR No Yes Yes No No No No No {See 5.51) Yes Yes PolysticklR-Xe Yes No No No No Yes Qoint strips,1507.1.1.3 [joint str;ps,1507.i.1.3 /R905.1.1.3) f R905.1.1.3J Yes Yes Polystick MTS Plus Yes Yes No Yes Yes Yes (joint strips,1507.1.1.3 (jaintstrips,1507.1.1.3 /R905.1.1.3) /R905.1.1.3) Yes Yes Polystick MU-X Yes No No Yes Yes Yes (joint strips,1507,1.13 (joint strips,1507.1.1.3 /11905.1.1.3) /R905.1.1.3) Yes Yes Yes Polystick TU Max No Yes Yes Yes No (See 5.6.1) {joint strips,1507.1.1.3 (joint strips,1507.1.1.3 /R905.1.1.3) /R905.1.1.3) Polystick TU P No yes Yes No No No Yes Yes (See 5.6.1) (joint steps,1507.1.1.3 [joint strips,I507.1.1.3 /R905.1.1.3) /R905.Z_1,31 Yes Yes Yes Polystick TU Plus Yes Yes Yes Yes Yes (See 5.6.1) (joint strips,1507.1.L3 [joint strips,1507.1.1.3 R905.U.3) /R905.1.13) Polystick XFR Yes Yes No Yes Yes Yes Yes Yes (joint strips,1507.1.1.3 {joint striRs,1507.1.1.3 /R905.1.L3) /R905.1.1.3j NEMO ETC,LLC. Evaluation Report P12060.02.09-1127 Certificate of Authoriwtion#32455 7r"EDITION(202D)FBC PION-HVHZ EVALUATION F1.5259-1131 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 5 of 17 ONEMOjetc. 5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations. TABLE IA:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE GOMBINATIONS2 Llnderlayment Adhesive Florida Product Approval Polystick TU Max or Polystick TU Plus DAP Foam"Touch'n Seal FL14506 StormSond Roof Tile Adhesive" HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Polystick Dupont"Tile Bond'"Roof Tile FL22525 TU Plus Adhesive" Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Polyset®AH-160" FL6332 Polystick TU P or Polystick TU Plus Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, FL6276 Polystick TU P or Polystick TU Plus "Polyset®RTA-1" 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTs Underlayment Application Substrates(designed to meet wind loads for project) Type Primer Material(s) HydraGuard Dual Pro, (Optional)ASTM plywood,OSB,Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro,Polystick 1R- Deck/ D41 Woods"ZIP System"Panels Xe,Polystick MTS Plus,Polystick sheathing ASTM D41 structural concrete MU-X,Polystick TU Max, Polystick TU P,Polystick TU Plus, self- (Optional}ASTM ASTM C1289 Type 11 Class 1 polyisocyanurate,ASTM Y Y adhering Insulation C1289 Type V polyisocyanurate-composite,DensDeck Cap Sheett,,Mule-Hide SA-APP Polystick Mule-Hide SA-APP D41 or W6 3000 Prime or SECUROCK Gypsum-Fiber Roof Board M Cap Sheet(FR),Polyflex SA P or Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P or Mule- Polyflex SA P FR Hide Nail Base Deck ASTM D41 structural concrete Elastoflex S6 G or Elastoflex S6 G Insulation (Optional)ASTM DensDeck Prime or5ECUROCK Gypsum-Fiber Roof Board FR hot asphalt D41 Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P,Mule- Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete torch- Insulation (Optional)ASTM DensDeck Prime or SECU ROCK Gypsum-Fiber Roof Board Polyflex G or Polyflex G FR applied D41 Base Sheet N/A Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass Base 2 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida ProductApproval for Overturning Moment Resistance Performance. NEMO ETC,LLC. Evaluation Report P32060.02.09-R27 Certificate of Autharization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 6 of 17 ONEMOletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1,1. 5.8.2 For use under the roof systems,attachment shall be in accordance with the manufacturer's installation instructions, but— for mechanically attached base sheets-not less than: • FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1(for Two- Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-52.5 psf: Deck: APA rated,7/16 CAT,0.418 in_,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min.4-inch wide strips of Eiastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #2 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #3 Maximum Design Pressure 97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Gap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x IN" ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch D.C. #4 Maximum Design Pressure=-105 psf; Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Primer: WB-3000 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y4'ring shank nails through 32 ga.,1-518"diameter tin caps spaced 12-inch D.C. NEMO ETC,LLC. Evaluation Report P12060.02.09-R27 Certificate ofAuthorimtion#32455 7-EDITION(2020)FSC NON-MVHZ EVALUATION FL5259-1131 Polyglass Roof Underlayrnents Revision 27,09/30/2020 Page 7 of 17 ONEMOletc. #5 Maximum Design Pressure=-135 psf: Deck- Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #6 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction, Primer: PG100 or A5TM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet(FR), Polyflex 5A P, Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #7 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #8 All other direct-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/Till Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements. #9 Maximum Design Pressure=-30.0 psf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch song x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows_ Base Ply: (optional)Polystick MTS Pius,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #10 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners. 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows_ Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #11 Maximum Design Pressure=-37.5 psf": Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. NEW ETC,LLC. Evaluation Report P12060.02.09-RZ7 Certificate of Authorization#31455 7Te EDITION(20ZO)FBC NON-HVHZ EVALUATION FL5259-1131 Polygiass Roof Underlayments Revision 27:09/30/2020 Page 9 of 17 ONEMOletc. #12 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch ox.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering Underlayment only)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered, #13 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type Il felt Fasteners: 11 ga_x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/9-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment:Mule--Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered or Elastoflex 56 G,applied in full mopping of hot asphalt. #14 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #15 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c,at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #16 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o,c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #17 _Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Poiyglass Base Fasteners: 12 ga.annular ring shank nails with 1-5/9"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #18 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. NEW ETC,LLC. Evaluation Report P12060.02.09-R27 Certifcateof Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVACUATION FL5259-1131 Polyglass Roof Underlayments Revision 27.0913012020 Page 9 of 17 ONEMOletc. #19 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide bail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c_at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self- adhered-Underlayment:Muie-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick TV P or Polystick TU Plus,self-adhered. #20 Maximum Design Pressure=-52.5psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied tap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-60psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt ortorch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25--inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-60psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OlV[G#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #23 Maximum Design Pressure=-60.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Clastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick TV P or Polystick TU Plus,self-adhered. #24 _Maximum Design Pressure=-60.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OS8 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows_ Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #25 Maximum Design Pressure=-60.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied, NEW ETC,LLC. Evaluation Report P12060.02.09-R27 Certificate of Authorization#32455 7-EDITION(2020)FHC NON-HVH2 EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 10 of 27 ONEMOletc. #26 Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #27 Maximum Design Pressure=-67.5 psf: Deck: APA rated, 19/32 CAT,0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180*into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates_ Base Ply: f Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex5A P FIR,Polystick TU Max,Polystick TU P or Polystick TU Plus,sef€-adhered. #28 Maximum Design Pressure=-67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c_at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #29 Maximum Design Pressure=-67.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners. TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #30 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underloyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvaiume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing. 10-inch o-c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #31 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #32 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. NEMO ETC,LLC. Evaluation Report P1206a.02.09-R27 Certifkate of Authorization#32455 7'"EDITION(2020)F8C NON-HVHZ EVALUATION FL5259-R31 Polygfass Roof Underlayments Revision Z7:09/30/2020 Page 11 of 17 ON EMO I etc. #33 Maximum Design Pressure=-90 psf: Deck: Min.15/32 inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c,at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows, Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. 434 Maximum Design Pressure=-90 psi: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG##14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underiayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #35 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underiayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TLJ Plus,self-adhered. #36 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.419 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 94nch o.c.at the 2-inch wide side laps and 12-inch o.c,at two(2)equally spaced staggered center rows. Underiayment:Elastoflex S6 G,applied in full mopping of hot asphalt. #37 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o-c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underiayment: Polyflex G,torch-applied. #38 _Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),PoiyfiexSA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. NEMO ETC,LLC. Evaluation Report P12060.02.09-1127 certificate of Authorization#32455 7"EDITION(2Q20)FBC NON-HVH2 EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 12 of 17 ON EMO I etc. #39 Maximum Design Pressure=-97,5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows, Primer: PG100 or ASTM B41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #40 Maximum Design Pressure=-97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. #41 Maximum Design Pressure=-97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #42 Maximum Design Pressure=-105 psf: Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #43 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Muie-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c_at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. #44 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. NEMO ETC,LLC. Evaluation Report P12060,02.09-RZ7 Certiffcare of Authorization#32455 7—EDITION(2020)FP,C NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 13 of 17 ONEMOletc. #45 Maximum Design Pressure=-105 0 psf.- Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #46 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch O.C.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS Plus,self-adhered Underlayment:Mule-Hide SA--APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,PolystickTU Max,Polystick TU P or Polystick TU Plus,self-adhered. 447 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o_c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #48 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underiayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #49 Maximum Design Pressure=-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Fxposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply; (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TO P or Polystick TU Plus,self-adhered. #50 Maximum Design Pressure=-127.5 psf; Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #51 _Maximum Design Pressure=-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. MEMO ETC,LLC. Evaluation Report P12060.02.09-R27 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-1131 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 14 of 27 OMEMO I etc. 5.9 Exposure Limitations: TABLE 3: ExPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure(days) Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick IR-Xe or Polystick MU-X Mechanically attached 90 HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus or Polystick XFR Any type(per Table 1) 180 Elastoflex 56 G,Elastoflex 56 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Adhesive-set the roof system 180 Sheet(FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) Prohibited without battens HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polystick MT5 Plus Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack(4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack(4 over 21 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC,LLC. Evaluation Report P12060,02.09-1127 Certificate of Authorization 932455 7-EDITION 12020)FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 15 of 17 0 NE o I etc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Muie-Hide Nail Base: 6.3.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM 0226,Type II) in FBC Table 1507.1.1.1 or FBC Residential Table 11905.1.1.1 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X,Polystick TU Max,Polystick TU P, Polystick TU Plus,Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1 Elastobase(poly-film top), Elastobase P(poly-film top)and Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the`TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,followed by Polystick MTS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick XFR, Polyflex SAP,Poiyflex SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered or Polyflex G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for attachment requirements. 6.3.2.2 Elastobase(sanded-top)and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the"TWO- PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380),asphalt-applied or Polyflex G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Gap Sheet,as set forth in Table 1. • When Elastobase (sanded-top) or Elastobase P (sanded-top)is followed by asphalt-applied Elastoflex S6 G,Elastoflex S6 G FR or FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380), refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1 or Section 5.8.3.2 herein for attachment requirements. • When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by torch-applied Polyflex G or Polyflex G FR,refer to Section 5.8.3.2 herein for attachment requirements. 6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P, Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X,Polystick TU Max,Polystick TU P,Polystick TU Plus or Polystick XFR: 6.4.1 General: All seal-lap seams (selvage laps) must be firmly rolled with a _ in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to thei end of the glue pattern(the sheet will overlap the fabric). View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro NEMO ETC,LLC. Evaluation Report P12060.02.09-1127 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27.09/30/2020 Page 16 of 17 ONEM10jetc. 6.4.2 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt, Elastobase,Elastobase P or Mule-Hide Nail Base,the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile Applications(excludes HydraGuard Dual Pro Polystick IR-Xe and Polystick M(LA: Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi-Ply Underlayment Systems: Polystick MTS Plus or PolystickXFR followed by HydraGuard Tile Pro,Polyflex SA P,Polystick MTS Plus,Polystick MU-X,Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive-set Mile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex S6 G or Elasto#lex S6 G FIR: 6.5.1 Shall be installed in compliance with requirements as an alternate to the 'Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Shall be installed in compliance with requirements as an alternate to the"Heat Applied Cap Sheet"in the"Two Ply System"in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 7. Buil-C)ING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. L S. MANUFACTURING PLANTS; Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY AssURANCE ENTITY: UL LLC—QUA9625; (414)248-6409;Karen.buchmann@ul.com -END OF EVALUATION REPORT- NEW ETC,LLC. Evaluation Report P12060.02.09-1127 Certificate of Authorization#32455 71"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 27 of 17