HomeMy WebLinkAbout402.4 32CHAPTER 4 GAS PIPING INSTALLATIONS TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST) Gas Undiluted Propane Inlet Pressure 11.0 in. w.c. Pressure Drop 0.5 in. w.c. Specific Gravity 1.50 2020 Florida Building Code, Fuel Gas, 7th Edition First Printing: Jul 2020 Copyright © ICC All Rights Reserved. Accessed by Energized Electric on 02/18/2021 pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Any Unauthorized reproduction or distribution is a violation of the federal copyright, and subject to civil and criminal penalties thereunder. INTENDED USE: SIZING BETWEEN SINGLE OR SECOND STAGE (Low Pressure) REGULATOR AND THE APPLIANCE SHUTOFF VALVE TUBE SIZE (EHD) Flow Designation 13 15 18 19 23 25 30 31 37 39 46 48 60 62 Length (ft)Capacity in Thousands of Btu per Hour 5 72 99 181 211 355 426 744 863 1,420 1,638 2,830 3,270 5,780 6,550 10 50 69 129 150 254 303 521 605 971 1,179 1,990 2,320 4,110 4,640 15 39 55 104 121 208 248 422 490 775 972 1,620 1,900 3,370 3,790 20 34 49 91 106 183 216 365 425 661 847 1,400 1,650 2,930 3,290 25 30 42 82 94 164 192 325 379 583 762 1,250 1,480 2,630 2,940 30 28 39 74 87 151 177 297 344 528 698 1,140 1,350 2,400 2,680 40 23 33 64 74 131 153 256 297 449 610 988 1,170 2,090 2,330 50 20 30 58 66 118 137 227 265 397 548 884 1,050 1,870 2,080 60 19 26 53 60 107 126 207 241 359 502 805 961 1,710 1,900 70 17 25 49 57 99 117 191 222 330 466 745 890 1,590 1,760 80 15 23 45 52 94 109 178 208 307 438 696 833 1,490 1,650 90 15 22 44 50 90 102 169 197 286 414 656 787 1,400 1,550 100 14 20 41 47 85 98 159 186 270 393 621 746 1,330 1,480 150 11 15 31 36 66 75 123 143 217 324 506 611 1,090 1,210 200 9 14 28 33 60 69 112 129 183 283 438 531 948 1,050 250 8 12 25 30 53 61 99 117 163 254 390 476 850 934 300 8 11 23 26 50 57 90 107 147 234 357 434 777 854 2020 Florida Building Code, Fuel Gas, 7th Edition First Printing: Jul 2020 Copyright © ICC All Rights Reserved. Accessed by Energized Electric on 02/18/2021 pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Any Unauthorized reproduction or distribution is a violation of the federal copyright, and subject to civil and criminal penalties thereunder. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m /h, 1 degree = 0.01745 rad. Notes: 1.Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length (feet) of tubing and n is the number of additional fittings or bends. 2.EHD—Equivalent Hydraulic Diameter, which is a measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing. 3.All table entries have been rounded to three significant digits. 3 2020 Florida Building Code, Fuel Gas, 7th Edition First Printing: Jul 2020 Copyright © ICC All Rights Reserved. Accessed by Energized Electric on 02/18/2021 pursuant to License Agreement with ICC. No further reproduction or distribution authorized. Any Unauthorized reproduction or distribution is a violation of the federal copyright, and subject to civil and criminal penalties thereunder.