Loading...
HomeMy WebLinkAboutSite planMotor / Light (Separate Circuit) NOTES: Panel Ground Fault Circuit Breaker (For Pump) - Water Proof Ground Fault Circuit Breaker (located 10' - 20' from water) ♦ Pump Motor Time Clock Integral with pump (_ /Transformer ,/Niche less Single Pole PAL Color TREO light 9 (No Junction Box Required) Single Throw Toggle Switch Pool Light NOTES: -Ground all metal boxes. -LED Niche -less light requires no ground. -Light fixture does not require GFCI or junction box Electric Diagram Not To Scale Pump Surface Water Level \ #8 Solid bare cooper bond wire w/ approved Clamps = One on each side of the pool TOTAL: 4 Screwed down with 1.5" Long 1/8 or larger approved concrete anchors N I \11 Filter \ Screwed down with 1.5" Long 1/8 or larger approved concrete anchors Pump & Filter Tie Top view / Not To Scale IS- min-24" max from Inside wall of pool �----� Bonded Ground Wire at 4 Points of Pool. 1 at Skimmer 1 Ground Rod at Equipment Pad (1) #8 Bare copper wire bonded to pool steel Equipotential Bonding Detail Per Florida Building Code Adaptation of N.E.C. 2008 sec680.26 Not To Scale Skimmer Vent Through Lid Water Level /Deck Surface 2" PVC Pipe / Schedule 40 Pump Suction Si e Minimum distance 3 feet apart (pipe centerlines) Pump Discharge (To Filter) Skimmer Detail Not To Scale Minimum distance 3 feet apart (pipe centerlines) r__ SINGLE Pump DUAL Pump VGB 2008 Compliant Main Drain Plumbing Detail Not To Scale e \ 2" Socket VGB 2008 Compliant 175 gpm Main Drain Plumbing Detail Not To Scale Pol Water Level 3/4" watertight, underground PVC conduit back to 120V AC/12V AC transformer location. All fittings should be glued and watertight inimum of 3 112" of straight, 1 1/2" PVC e behind wall fitting required prior to tduit reducer or bend. No -Niche LED Light Detail Not To Scale 1. PLANS AND ENG IN EER ING ACCOR DANCE WITH THE FLORIDABUILDING CODE RESIDENTIAL 2014, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 2. ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2014, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7. 3. ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL BE COMPLY WITH FBC PLUMBING 2014. 4. ALL POOL AND SPA SHALL BE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM. 5. ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH 48 GROUND WIRE PER NEC 680. 6. POOLAND SPASHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE, HOUSE SAFETY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4502.17.1 7. ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2014 (SEPARATE CONTRACTOR). 8. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH NEC 2011 EDITION. 9. POOLAND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD. 10. AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LICENSED LEGEND: POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED. 11. HEATING EQUIPMENT SHALL COMPLY WITH FBC R 2014. 12. POOL BY VIKING POOLS, DONALD R. POINDEXTER P.E. L-nioui:y "xGavaleu vval Specifications: Pool Model: Surface Area: Light: No -Niche LED Pool Returns: VAC Stubout: Approved VAC Lock Fitting Interior Finish: FIBERGLASS WITH GELCOAT Pump #1: Filter: in. pipe Pool Main Drain connecting pipe in. pipe Spa Main Drain connecting pipe in. pipe Spa Therapy Suction in. pipe Suction Cleaner Line in. pipe Pool Skimmer Line in. pipe Pool Return Line in. pipe Spa Return Line in. pipe Pool Therapy Return Line in. pipe Spa Therapy Return Line SITE PLAN SCALE:1 "=40'-0" Dimensions: Perimeter: Total Watts: Capacity (gals): Turnover rate (minutes): Pump #2: Filter Square Footage: ENGINEER CERTIFICATION LEGAL DESCRIPTION: OLMSTEAD PLACE S/D THAT PART OF LOT 1 MPDAF: FROM INT OF S LI LOT1 AND WLY R/W IND RVR DR, TH WLYALG S LI OF SD LOT 1 45 FT Pool Return Spa Return Skimmer Vent Line Suction Cleaner Pool Therapy Return Spa Therapy Return Spa Main Drain Pool Main Drain CF) EQUIPMENT PAD OWNER: Forest and Kathryn Blanton 6905 S Indian River Dr Fort Pierce FL 34982 POOL CONTRACTOR: GEOFFROY (GEOFF) P HILAIRE All America Pools, Inc 257 SW Port Saint Lucie Blvd Port Saint Lucie FL 34984 Office:(772) DIG -POOL (344-7665) Florida Certified Pool Contractor CPC-057355 Parcel # 3412-502-0002-000-9 6905 S INDIAN RIVER DR FORT PIERCE, FL 34f AREA=81,457 SF (1.87 ACRES)