HomeMy WebLinkAboutSite planMotor / Light
(Separate Circuit)
NOTES:
Panel
Ground Fault
Circuit Breaker
(For Pump) -
Water Proof
Ground Fault Circuit Breaker
(located 10' - 20' from water)
♦ Pump Motor
Time Clock
Integral with pump
(_ /Transformer
,/Niche less
Single Pole PAL Color TREO light
9 (No Junction Box Required)
Single Throw
Toggle Switch
Pool Light
NOTES: -Ground all metal boxes.
-LED Niche -less light requires no ground.
-Light fixture does not require GFCI or junction box
Electric Diagram
Not To Scale
Pump
Surface
Water Level \
#8 Solid bare
cooper bond
wire w/ approved
Clamps = One on each
side of the pool
TOTAL: 4
Screwed down with 1.5"
Long 1/8 or larger approved
concrete anchors
N
I \11
Filter
\ Screwed down with 1.5"
Long 1/8 or larger approved
concrete anchors
Pump & Filter Tie
Top view / Not To Scale
IS- min-24" max
from Inside wall of pool
�----� Bonded Ground Wire
at 4 Points of Pool.
1 at Skimmer
1 Ground Rod at Equipment Pad
(1) #8 Bare copper wire
bonded to pool steel
Equipotential Bonding Detail
Per Florida Building Code Adaptation of
N.E.C. 2008 sec680.26
Not To Scale
Skimmer
Vent Through Lid
Water Level
/Deck Surface
2" PVC Pipe /
Schedule 40
Pump Suction Si e
Minimum distance 3 feet apart
(pipe centerlines)
Pump Discharge
(To Filter)
Skimmer Detail
Not To Scale
Minimum distance 3 feet apart
(pipe centerlines) r__
SINGLE Pump DUAL Pump
VGB 2008 Compliant
Main Drain Plumbing Detail
Not To Scale
e
\ 2" Socket
VGB 2008 Compliant
175 gpm Main Drain Plumbing Detail
Not To Scale
Pol
Water Level
3/4" watertight, underground PVC
conduit back to 120V AC/12V AC
transformer location.
All fittings should be glued and
watertight
inimum of 3 112" of straight, 1 1/2" PVC
e behind wall fitting required prior to
tduit reducer or bend.
No -Niche LED
Light Detail
Not To Scale
1. PLANS AND ENG IN EER ING ACCOR DANCE WITH THE FLORIDABUILDING CODE RESIDENTIAL
2014, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7.
2. ALL CONSTRUCTION AND INSTALLATIONS TO COMPLY WITH THE FLORIDA BUILDING CODE
RESIDENTIAL 2014, ANSI/NSPI 3, ANSI/NSPI 4, ANSI/NSPA 5, ANSI/NSPI 6, and ANSI/APSP 7.
3. ALL PIPING SHALL BE SCH 40 OR SCH 80 PVC, AND INSTALLATIONS SHALL BE COMPLY WITH FBC PLUMBING 2014.
4. ALL POOL AND SPA SHALL BE CONTINUOUS SOIL BEARING ON CLEAN COMPACTED SOIL WITH 2O00 PSF MINIMUM.
5. ALL HANDRAILS, LADDERS, LIGHTS SHALL BE BONDED WITH 48 GROUND WIRE PER NEC 680.
6. POOLAND SPASHALL BE PROVIDED WITH APPROVED CHILD BARRIER OR SCREEN ENCLOSURE,
HOUSE SAFETY BARRIER OR ALARM SYSTEM ALL IN ACCORDANCE WITH FBCR 4502.17.1
7. ALL GAS AND FUEL PIPING SHALL BE PER FBC FUEL AND GAS 2014 (SEPARATE CONTRACTOR).
8. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH NEC 2011 EDITION.
9. POOLAND SPA EQUIPMENT SHALL BE SECURED TO CONCRETE PAD.
10. AFTER COMPLETION OF POOL CONSTRUCTION, HOMEOWNER SHALL CONSULT LICENSED LEGEND:
POOL CONTRACTOR IN ORDER TO DRAIN POOL IF SO DESIRED.
11. HEATING EQUIPMENT SHALL COMPLY WITH FBC R 2014.
12. POOL BY VIKING POOLS, DONALD R. POINDEXTER P.E.
L-nioui:y "xGavaleu vval
Specifications:
Pool Model:
Surface Area:
Light: No -Niche LED
Pool Returns:
VAC Stubout: Approved VAC Lock Fitting
Interior Finish: FIBERGLASS WITH GELCOAT
Pump #1:
Filter:
in. pipe Pool Main Drain connecting pipe
in. pipe Spa Main Drain connecting pipe
in. pipe Spa Therapy Suction
in. pipe Suction Cleaner Line
in. pipe Pool Skimmer Line
in. pipe Pool Return Line
in. pipe Spa Return Line
in. pipe Pool Therapy Return Line
in. pipe Spa Therapy Return Line
SITE PLAN
SCALE:1 "=40'-0"
Dimensions:
Perimeter:
Total Watts:
Capacity (gals):
Turnover rate (minutes):
Pump #2:
Filter Square Footage:
ENGINEER CERTIFICATION
LEGAL DESCRIPTION:
OLMSTEAD PLACE S/D THAT PART OF LOT 1
MPDAF: FROM INT OF S LI LOT1 AND WLY R/W IND RVR DR,
TH WLYALG S LI OF SD LOT 1 45 FT
Pool Return
Spa Return
Skimmer
Vent Line
Suction Cleaner
Pool Therapy Return
Spa Therapy Return
Spa Main Drain
Pool Main Drain
CF)
EQUIPMENT PAD
OWNER:
Forest and Kathryn Blanton
6905 S Indian River Dr Fort Pierce FL 34982
POOL CONTRACTOR:
GEOFFROY (GEOFF) P HILAIRE
All America Pools, Inc
257 SW Port Saint Lucie Blvd
Port Saint Lucie FL 34984
Office:(772) DIG -POOL (344-7665)
Florida Certified Pool Contractor CPC-057355
Parcel # 3412-502-0002-000-9
6905 S INDIAN RIVER DR FORT PIERCE, FL 34f
AREA=81,457 SF (1.87 ACRES)