HomeMy WebLinkAboutProduct Approval 11� ,
9/29/2017 �i� — Florida Building Code Online
t�
BCIS Home Log In User Registration Hot Topics t Submit Surcharge Stats&Facts i Publications FBC Staff ; BCIS Site Map Links S ~Search ;
Florida
Product Approval
d.I..... I;p
r USER:Public User
i Product Approval Menu>Product or Application Search>Application List>Application Detail
#� FL# FL21383 b
Application Type New OD
Code Version 2014 ST. LUCIE COUNTY
Application Status Approved BUILDING DIVISION
.REVIEWS:D.
Comments P I y �����'�� 111 � r1 REVIEWED 1(ED BY
Archived !. , . IIII=.QF.) () iioiE)jjj DATE P AND
PE 1fiIT
MUST dE KEPT ON JOB OR
z
Product Manufacturer �: "' J Sunlast Metal NO INSPE-CTIOM WILL EC MADE
Address/Phone/Email 2120 SW Poma Drive --
Palm City,FL 34990
(772)223-4055
fIva lidation@yahoo.com
j Authorized Signature Terry Kapron
fivalidation@yahoo.com
I
Technical Representative
Address/Phone/Email THESE PLANS AND ALL PROPOSFD WORK
ARE SU€MECT TO AN;'-I CN-PIP I:CTIONS
Quality Assurance Representative Rl QIREL�CRr*FIELD IFIaC7 . TM�T
Address/Phone/Email MAY BE NECESSARY IN=—ER TO
COMPLY WITH All A."PUCACiLF;000E6,
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who developed James Biagi
the Evaluation Report
Florida License PE-37467
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 03/02/2026
Validated By Locke Bowden
d.i Validation Checklist-Hardcopy Received
Certificate of Independence FL21383 RO COI James Biaoi P E Certificate of Independence odf
i
Referenced Standard and Year(of Standard) Standard Year
UL 580 2006
Equivalence of Product Standards
Certified By
17
Sections from the Code FILE C IV"
Product Approval Method Method 1 Option D
https://www.floddabuilding.org/pr/pr app dU.asp)?param=wGEVXQwtDgveOD7nSKOaGOtHldp/p2bwQOEnpeBiKF3uZJQkWyizvE°/p2bvrgp/o3d%3d 1/2
9/29/2017 Florida Building Code Online •
� e
Date Submitted 12/16/2016
Date Validated 12/16/2016
Date Pending FBC Approval 12/22/2016
Date Approved 02/07/2017
Summary of Products
FL# Model,Number or Name Description
21383.1 ECONO LINE 1.0 CLIPLESS NAIL 26GA STEEL OVER 15/32"4 PLY COX PLYWOOD
STRIP
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL21383 RO II ECONO LINE SERIES CLIPLESS NAIL STRIP
Approved for use outside HVHZ:Yes 26GA ss-Fnal.pdf
Impact Resistant: N/A Verified By: Architectural Testing,Inc.-Florida
Design Pressure: +n/a/-71PSF Created by Independent Third Party:Yes
Other: -71PSF @6"O.C.INSTALL PER MANUFACTURER'S Evaluation Reports
i DETAILS AND IN COMPLIANCE WITH FBC 2014. FL21383 RO AE ECONO LINE SERIES CLIPLESS NAIL STRIP
26GA ss-Final.pdf
Created by Independent Third Party:Yes
21383.2 ECONO LINE 1.0 NAIL STRIP ALUM .032 ALUM OVER 15/32"4-PLY CDX PLYWOOD
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL21383 RO II ECONO LINES SERIES CLIPLESS NAIL STRIP
Approved for use outside HVHZ:Yes ALUM ss.FINAL.Ddf
Impact Resistant: N/A Verified By: Architectural Testing,Inc. -Florida
Design Pressure: +N/A/-78PSF Created by Independent Third Party: Yes
Other: -78PSF @6"O.C.INSTALL PER MANUFACTURER'S Evaluation Reports
DETAILS AND IN COMPLIANCE WITH FBC 2014. FL21383 RO AE ECONO LINES SERIES CLIPLESS NAIL STRIP
ALUM ss.FINAL.pdf
Created by Independent Third Party:Yes
21383.3 ECONO LINE PBR 26GA STEEL OVER 15/32"4-PLY CDX PLYWOOD
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL21383 RO II ECONO LINE SERIES-PBR ss-1FINAL.Ddf
Approved for use outside HVHZ:Yes Verified By: Architectural Testing,Inc.-West Palm Beach,FL
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-76.75 Evaluation Reports
Other: -76.75PSF @ 24"O.C.Additional fastening for panel FL21383 RO AE ECONO LINE SERIES-PBR ss-1FINAL.Ddf
overlaps @4"O.C.spacing Install per FBC 2014 and Created by Independent Third Party: Yes
manufacturer's details.
$aGk C4eXt
i
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mall address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
Credit Card"
Sc'i�e:` .:
https://www.floddabuilding.org/pr/pr app_df.aspx?param=wGEVXQwtDgve007nSKOaGOtHld°/p2bwOOEnpeB!KF3uZJQkWyizvEp/o2bvrg%3d%3d 2/2
1
E
f
S un/ast Meta/
Value Engineered Meta/Roofing
S • , PRODUCT APPROVAL
0 bk)
26 GA. 6♦" 0
VERGE, WIDTH R®®,F PANEL ��/ER 95/32" PLY410P �®
F RICA PR®®UCT-APPROVAL 1VO 21383 1
-SERIES
Product Evaivation Report
1"CLIPLESS NAIL.STRIP 26GA Roof Panel over 15/32"Plywood
Florida_Product.Approval# 21383.1
Florida Building Code 2014 Per Rule 61G20-3
Method:I—D
Category:Roofing Subcategory:Metal Roofing Compliance Method:
Rule 61G20.3
NON-HVHZ
Product Manufacturer:
Sunlast Metal
2120 SW Poma Drive Palm City,Florida 34990
Eneineer Evaluator
James Biagi, P.E.FL#37467
1915 NE W ST.#107
Fort Lauderdale,FL 33308
954-776-8004
Vali ator•
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place „��'t.c►.rrti.�� "
Montgomery,AL 36117 i'�' .gyp�j F.
Evaluation Report 1-4
James Bia .E.
FL# 46`j Lr
TAT EO 4i
eal J R �t:•'r��,
Page 1 of 4
Compliance Statement:The product as described in this report has demonstrated compliance with the
Florida Building Code 2014,Sections 1504.3.2,1507.4.3,
Product Description:26GA Nail Strip/Snap Lock Metal Panel,16"Coverage Width, Roof panels,1.0"Rib height
i Panel restrained with#10 x 1" Pancake Head fasteners into 15/32"4 ply CDX Plywood decking.
Non-structural Application.
FOR USE IN NON-HVHZ.
Material:26GA metal conforming to Florida Building Code 2014 Section 1507.4.3 Yield Strength:40KSI
Corrosion Resistance:Panel Material shall comply with Florida Building Code 2014,Section 1506.6,1507.4.3,1507.4.4
Panel Dimensions:Panel Width:16"coverage width
Fastener:#10 X 1" Pancake-Head wood fasteners or equivalent. Corrosion Resistant per Florida Building Code 2014 Section
1506.7. 3/16"minimum penetration through plywood
Corrosion Resistance:Per Florida Building Code 2014,Section 1506.6,1507.4.4
15/32"4ply CDX plywood,plywood supports at maximum 24'O.C.Design of plywood and plywood supports are outside the
scope of this evaluation.Must be designed in accordance w/Florida Building Code 2014.
Design Uplift Pressures:Uplift Design Pressure:with Safety Factor of 2
TABLE A
i
Max Design Pressure -71psf
Field Fastener Spacing 6"from panel ends and 6"o.c.
Fastener Size #10 Female leg of panel snap fit to the male leg of the adjacent panel.
Quality Assurance:In accordance with FBC 2014 and Rule#61620-3:Keystone Certification,
Inc.QUA 1824
I
Test References:
Architectural Testing Inc(TST 1527)#F8542.01-450-44 UL 580-06
Code Compliance:The product described herein demonstrated compliance with The Florida Building Code(FBC)2014 Section
1504.3.2.The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2014,as relates
to Rule 61G20-3.
Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2014,and in accordance with Manufacturers
recommendations.
Installation:Install per manufacturer's recommended details in compliance with FBC 2014.
Underlayment:Per Manufacturer's installation guidelines per Florida Building Code 2014
Roof Panel Fire Classification:No classification.
Shear Diaphragm:values are outside the scope of this report.
F! i .
ff
Design Procedure:Based on the dimensions of the structure,applicable wind loads are demi_tern,ed:using Chapter 16 of the
Florida Building Code 2014 for roof cladding wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the applicable erection details to reference in drawings for
correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover.Support framing must be
Page 2 of 4
compliant with Florida Building Code 2014 Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
Required wind loads shall be determined per project per FBC 2014 and any rational analysis computation shall be prepared by a
licensed design professional.
Certificate of Independence:James Biagi,P.E.does not have nor will acquire financial interest in any company manufacturing or
distributing products under this evaluation.James Biagi, P.E.is not owned or operated or controlled by any company
manufacturing or distributing product under this report.
I
I
I
i
I
i
I
I
I
I
(PRODUCT EVALUATION REPORT
Page 3 of 4
J.:
.S_ uh/ast Mega/
Value Engineered Meta/Roofing r"'
ECONO LINE (26GA CLIPLESS 1 .0 NAIL STRIP/SNAP LOCK)
INSTALL DETAILS
Fastener:#10 Pancake Head Wood Fastener
Sunlast Econo 1" Clipless �`" �
PANEL PROFILE
o
o
r
Striations Optional 26GAWE T� EW SPACING
(Flat Shown)
Sunlast Econo 1" Clipless
PANEL PROFILE
-F
J-0\—�
Striations Optional 26GAUGE
(Flat Shown)
IW&Y
Page 4 of 4