Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department * Building & Code Regulations Division - -_ - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: HAB - 3BRHC - 7803 James Street Project Address: 7803 James Street, Fort Pierce, FL 34951 Permit #: Occupancy Type: VB Construction Type: R-3 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit'(2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residence's (single or multi -.family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B x C D 4. Design Wind Velocity 170 mph ASD x LRFD End Zone Width: ft 5. Mean Roof Height 10,111, ft Roof Pitch: 4 :12 Parapet: 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on aff:P Zone 1: -57.65 Zone 2: -100.36 Zone 3: -148.41 Zone 4: -68.33 Zone 5: -84.35 G 7. Design Loads: Floor: PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcon Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? .X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes i DESIGN PROFESSIONAL CERTIFICATION STATEMENT: . I certify that, to the best o ji.,yltinyledge and belief, the attached plans & specifications have been designed to fir.. comply with>.th`e _appli l :tMct7!9Ap,.- y �,ons of the building codes currently adopted and enforced by St. Lucie o County. I also ce s:s�tilt15(rg'1eg'eftdepicted on these plans provide adequate resistance to the design forces specified , :.- - ,�� �• °�'_ �„ i*16ony Tombo FL. 80083 31615 �j�fiffain�e Cert # & Co. Cert Auth. e House Engineering, L.L.C. Ab 1Signature, Date, and••°''��'a�451 St. Lucie Blvd. Fort Pierce, FL 34946 tiros Company Name & Address I L �- 'Pile COON' Revised 07/25/2014 3BBCA22100 0000004C1287DIF i NOTICE OF PRODUC A CERTIFICATION Company: JELD-WEN Doors Certification No.: _ NI011233-R2 3737 Lalcesport Drive Certification Date: 08/14/2012 Klamath Falls, OR 97601 Expiration Date: 08/31/2020 Revision Date: 05/16/2016 Product: Contours Steel Opaque Steel Edged Door (w/Wood Frame) Specification: PA 201-94/202-94/203-94 The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Naniieertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI). Inswing Glazed Design Water Missile Test Report her Configuration or or Maximum Pressure 'rest Impact Drawing N er & outswing Opaque Size Pos/Neg, Pressure Rated Com►nf � X 1/S Opaque 3'2" x 6' 10" +80/-80 2.86 psf Yes CTLA6560 �C�" � Single g Max Panel Size 6'8" w/ Kwiksct 700 Latch & DcVXlt� ADA Threshold Qualifies Conri Mur ti" ns: X X O/S Opaque 3'2" x 6' 10" +80/-80 12.0 psf Yes CTLA650W Single Max Panel Size: 3'0" x 6'8" w/ Kwikset 700 Latch & Deadbolt & Endura 4566A Threshold Qualifies Configurations: X X I/S Opaque, 3'2" x 6' 10" 1 80/-80 2.86 psf Yes CTLA650W Single Max Panel Size: 3'0" x 6'8" w/ Kwikset 700 Latch & Deadbolt & ADA Threshold Qualifies Configurations: X X O/S Opaque 37' x 6' 10" +80/-80 12.0 psf Yes CTLA650W pit." Single `Itircj8�t k@Wj jgc Latch & Dcadb[lll V' I James Street 38RHCIlI`s�l"I`I aw' l 1i; 111t1Eti \,oflfiI-tilations: ' .�• - ............._..---...._.._...-..'. ........._.._........ ..._..-...z.-..- -- ' X O/S Opaque 3 7' x 6' 10" -180/-80 12.0 psf Yes .,. 0 APPRO\�jb\ 1 find Sizc:.IQ l 666TED Single :00 Lall'h &k Dea(lb[)II{k llnherial High Dam tJ REVISE NOT REVIEWED Thresh011 l f�lyy,lilil:•ti 1i:ulJ tz rui-my BY atombo DATE 12/11/2017 SUBMITTAL# SPEC i National Accreditation & Management Institute, Inc./4794 George Washington Memorial Hi ►)tt''�V �y•{{���1['",yy��, ±;"r `Jr' "" fj�}% �IU:ep:ojectandllerlual •.O:�u,f;.",rL,.,Z [jf 1j: rl,{,Tfl,'nt c orl these d:'nwings duting this Tel: (804) 684-5124/Fax: (804) 684-5122 rt7 liolai:; : <: ,::f a;;lo:: S.:Uconlr�cte: from c,)rnp1ign.a7 wilt) the u•qui; [;:l;a: d•:.;I thr: ;:6Zr� •.uid ,j rtn;;h;.Zli�::t;.. i:onh atlr:r c; : es;ponsible IRr all thmensv::': ar ir.7Lri ,nZr: p ba Conli:sled and cnnelaled it the job vita 1'1 NAMI AUTHORIZED SIGNATURE: FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: 7803 James Street BuilderName: Habitat for Humanity Street: 7803James Street Permit Office: 5 L C City, State, Zip: Ft. Pierce, FL, PermitNumber: 1710-0531 Owner: Habitat for Humanity Jurisdiction: Saint Lucie County DesignLocation: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New(FromPlans) 9. Wall Types (1424.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1182.00 ft2 b. Concrete Block- Int Insul, Adjacent R=4.1 242.00 ft2 3. Number of units, if multiple family 1 c. N/A R=, ft2 4. Number of Bedrooms 4 d. N/ _ ft2 5. Is this a worst case? No . eiling Types (1536.0 sqft.) Insula ion r a. Under Attic (Vented) 2 R=30.0 1536.00� 6. Conditioned floor area above grade (ft� 1536 b. N/A R= ftZ Conditionedfloorareabelo 0 c N/A R= ft2 11. Ducts 2 7. Windows(160.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 307 a. U-Factor: Dbl, U=0.33 160.17 ft2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.220 14. Hot water systems a. Electric Cap:40 gallons 8. Floor Types (1535.7 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1535.70ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.104 Total Proposed Modified Loads: 50.95 PASS Total Baseline Loads: 50.80 I hereby certify that the plans and specifications covered by Review of the plans and�HE 41, . this calculation are in compliance wit he Florida Energy specifications covered by this 0 c�ik: Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. Before construction is completed f+n,,' DATE: 12P_C2n. 6f.f ? , Zo I this building will be inspected for compliance with Section 553.908 I hereby certify that this building as designed, is in compliance Florida Statutes. with the Florida Ener Code. COD 1qf 1 OWNER/AGENT: BUILDING OFFICIAL: DATE: 2- DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. g,�° �0' - Compliance requires an Air Barrier and Insulation Inspection Checklist in al'cild'ance witfi 402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 12/6/2017 2:58 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: 7803 James Street Bedrooms: 4 Address Type: StreetAddress Building Type: User ConditionedArea: 1536 Lot# Owner: Habitat for Humanity Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: Habitatfor Humanity RotateAngle: 0 Street: 7803 James Street Permit Office: CrossVentilation: No County: St. Lucie Jurisdiction: Saint Lucie County Whole House Fan: No City, State, Zip: Ft. Pierce, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: Parcel#1301-603-0021-000/1 CLIMATE j IECC Design Temp Int Design Temp Heating Design DailyTemp v DesignLocation TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1536 12288 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bed 195 1560 No 1 1 1 Yes Yes Yes 2 cist 2 19 149 No 0 1 Yes Yes Yes 3 Bath 2 112 896 No 0 1 Yes Yes Yes 4 be 16 130 No 0 1 No Yes Yes 5 cist 3 17 136 No 0 1 Yes Yes Yes 6 Bed 3 197 1576 No 1 1 1 Yes Yes Yes 7 Living Rm 336 2685 No 0 1 Yes Yes Yes 8 Kitchen 169 1352 Yes 0 1 1 Yes Yes Yes 9 Dining Rm 126 1011 No 0 1 Yes Yes Yes 10 Ldry 26 210 No 0 1 Yes Yes Yes 11 Bed 207 1656 No 2 1 1 Yes Yes Yes 12 cist 1 16 126 No 0 1 Yes Yes Yes 13 Bath 1 100 802 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood I Carpet 1 Slab -On -Grade Edge Insulation Bed 2 32.3 ft 0 195.2 ftz ---- 1 0 0 2 Slab -On -Grade Edge Insulation clst 2 2.8 ft 0 18.6 ftZ ---- 1 0 0 3 Slab -On -Grade Edge Ins ulation Bath 2 9 ft 0 112 ftZ ---- 1 0 0 4Slab-On-Grade Edge Insulation be 1 ft 0 16.3ft2 ---- 1 0 0 12/6/2017 2:58 PM EnergyGauge®USA -FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation clst 3 2.5 ft 0 16.9 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation Bed 3 26.8 ft 0 196.9 ft2 ---- 1 0 0 7 Slab -On -Grade Edgelnsulation Living Rm 16.5 ft 0 335.6 ft2 ---- 1 0 ' 0 8Slab-On-Grade Edge Insulation Kitchen 11.3ft 0 168.8ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation Dining Rm 6.5 ft 0 126.4 ft2 _--- 1 0 0 10SIab-0n-Grade Edge Insulation Ldry 3.5 It 0 26.3 ftz ____ 1 0 0 11SIab-On-Grade Edge Insulation Bed 1 14.3 ft 0 206.6 ft2 _--- 1 0 0 12SIab-On-Grade Edge Insulation clst 1 2.3 ft 0 15.8 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation Bath 20.3ft 0 100.3ft2 ---- 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck; Pitch �/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Compositionshingles 1618 ft2 256 ft2 Medium 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1535 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic (Vented) Bed 2 30 Blown 195 ft2 0.1 Wood 2 UnderAttic (Vented) clst 2 30 Blown 19 ft2 0.1 Wood 3 UnderAttic (Vented) Bath 2 30 Blown 112 ft2 0.1 Wood 4 UnderAttic(Vented) be 30 Blown 16ft2 0.1 Wood 5 UnderAttic (Vented) clst 3 30 Blown 17 ft2 0.1 Wood ! 6 UnderAttic (Vented) Bed 3 30 Blown 197 ft2 0.1 Wood 7 UnderAttic (Vented) Living Rm 30 Blown 336 ft2 0.1 Wood 8 UnderAttic (Vented) Kitchen 30 Blown 169 ft2 0.1 Wood 9 UnderAttic (Vented) Dining Rm 30 Blown 126 ft2 0.1 Wood 10 UnderAttic (Vented) Ldry 30 Blown 26ft2 0.1 Wood 11 UnderAttic (Vented) Bed 30 Blown 207ft2 0.1 Wood 12 UnderAttic (Vented) clst 1 30 Blown 16 ft2 0.1 Wood 13 UnderAttic(Vented) Bath 30 Blown 100ft2 0.1 Wood 12/6/2017 2:58 PM EnergyGauge® USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 10 WWII\=Space hle Fraction Ahsn 1 N Exterior Concrete Block- Int Insul Bed 2 4.1 14 3 8 0 114.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block- Int Insul Bed 2 4.1 5 9 8 0 46.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Bed 2 4.1 12 3 8 0 98.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Int Insul clst 2 4.1 2 9 8 0 22.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block- Int Insul Bath 2 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 6 W Exterior Concrete Block- Int Insul cast 3 4.1 2 6 8 0 20.0 ft2 0 0 0.6 0 7 S Exterior Concrete Block- Int Insul Bed 3 4.1 14 3 8 0 114.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Int Insul Bed 3 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 9 N Exterior Concrete Block- Int Insul Living Rm 4.1 16 6 8 0 132.0 ft2 0 0 0.6 0 10 E Garage Concrete Block - Int Insul Living Rm 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _ 11 N Garage Concrete Block- Int Insul Living Rm 4.1 4 9 8 0 38.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block- Int Insul Kitchen 4.1 11 3 8 0 90.0 ft2 0 0 0.6 0 13 S Exterior Concrete Block- Int Insul Dining Rm 4.1 6 6 8 0 52.0 ft2 0 0 0.6 0 14 S Exterior Concrete Block- Int Insul Ldry 4.1 3 6 8 0 28.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block- Int Insul Bed 1 4.1 14 3 8 0 114.0 ft2 0 0 0.6 0 16 N Garage Concrete Block- Int Insul Bed 1 4.1 14 6 8 0 116.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block- Int Insul clst 1 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block- Int Insul Bath 1 4.1 5 9 8 0 46.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Int Insul Bath 1 4.1 14 6 8 0 116.0 ft2 0 0 0.6 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Living Rm None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation IntShade Screening 1 N 1 None Low-EDouble Yes 0.33 0.22 17.5 ft2 1 ft 6 in 1 ft 0 in None None 2 W 3 None Low-EDouble Yes 0.33 0.22 17.5 ft2 1 ft 6 in 1 ft 0 in None None 3 W 5 None Low-EDouble Yes 0.33 0.22 7.5 ft2 1 ft 6 in 1 ft 0 in None None 4 S 7 None Low-EDouble Yes 0.33 0.22 17.5 ft2 1 ft 6 in 1 ft 0 in None None 5 W 8 None Low-EDouble Yes 0.33 0.22 17.5 ft2 1 ft 6 in 1 ft 0 in None None 6 N 9 None Low-EDouble Yes 0.33 0.22 26.7 ft2 1 ft 6 in 1 ft 0 in None None 7 S 12 None Low-EDouble Yes 0.33 0.22 10.5 ft2 1 ft 6 in 1 ft 0 in None None 8 S 13 None Low-EDouble Yes 0.33 0.22 20.5 ft2 1 ft 6 in 1 ft 0 in None None 9 E 15 None Low-EDouble Yes 0.33 0.22 17.5 ft2 1 ft 6 in 1 ft 0 in None None 10 S 19 None Low-EDouble Yes 0.33 0.22 7.5 ft2 1 ft 6 in 1 ft 0 in Drapes/Winds Exterior5 12/6/2017 2:58 PM EnergyGauge®USA- FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 GARAGE # FloorArea CeilingArea ExposedWall Perimeter Avg.WallHeight Exposed Wall Insulation 1 382.8 ft' 384 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1024.1 56.22 105.73 .1906 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 35 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40gal 60.9gal 120deg None SOLAR HOT WATER SYSTEM FSEC Cert # CompanyName Collector Storage System Model# CollectorModel# Area Volume FEF None None ftz DUCTS # — Supply— Location R-Value Area — Return — Air CFM 25 CFM25 Location Area LeakageType Handier TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 307 ftZ Attic 77 ftZ DefaultLeakage Attic (Default) c(Default) c 1 1 12/6/2017 2:58 PM EnergyGauge® USA -FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 i FnRnn Rangy-gnlA TEMPERATURES ProgramableThermostat: N Ceiling Fans: CoolingHJan HeatinJan Feb HFeb Mar MMar �Apr Ar I Ma May Jun Jun Jul Jul u u Mug Se Sep Oct Oct MNOV Nov Dec Dec Ventin Jan Feb Mar A r May Jun Jul Se [X] Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM .65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 l 12/6/2017 2:58 PM EnergyGauge®USA- FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 I FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 7803 James Street, Ft. Pierce, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1182.00 ftz b. Concrete Block - Int Insul, Adjacent R=4.1 242.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 1536.00 ftz 6. Conditioned floor area (ftz) 1536 b. N/A R= ftz 7. Windows- Description . N/Aucts R_ Area z a. U-Factor: Dbl, U=0.33 11. 160.17 ftz a. Sup: Attic, Ret: Attic, AH: Attic R ftz 6 307 SHGC: SHGC=0.22 b. U-Factor: N/A ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.3 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1535.70 ftz a. Electric Cap: 40 gallonsEF: 0.92 b. N/A R= ftz c. N/A R= ftz b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see, the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT 12/6/2017 2:58 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 - wrightsoft® Load Short Form Entire House WebREPS, LLC Job: 7803 James Street Date: June 28, 2017 By: Josh Putman Plan: 7803 James Street 1892 Commerce Averue, Vero Beads, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepdwaccom Web: vwaw.webrepswholesale.com License: CAC054709 For. Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft Pierce, FL 34947 Phone: 772-460-6336 'Design In• • Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gdlb) 0 59 HEATING EQUIPMENT Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 21 °F 1167 cfm 0.066 cfmBtuh 0.60 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160361F Coil ASPT42D14A AHRI ref 5756175 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Airflowfactor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 24500 Btuh 10500 Btuh 35000 Btuh 1167 cfm 0.053 cfmBtuh 0.60 in H2O 0.74 ROOM NAME Area M Htg load (Btuh) Clg load (tuh) Htg AVF (cfirn) CIgAVF (ulli) Bed 2 195 3477 3000 231 158 cast 2 19 0 0 0 0 Bath 2 112 1196 1085 79 57 be 16 0 0 0 10 clst 3 17 0 0 0 10 Bed 3 197 2968 2933 197 155 Living Rm 336 3019 5040 200 266 Kitchen 169 1259 3741 84 197 Dining Rm 126 1207 2258 80 119 Ldry 26 0 0 0 1 0 Bed 1 207 2290 2999 152 158 clst 1 16 0 0 0 0 Bath 1 100 2157 1071 Vjje C 56 I Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Deo-0614:27:04 AM,,..• wte w« gym, Right Sute® Uriversal 201818.0.04 RSU16998 .bitaMr Hunarity PSL%7803 James Street#2np Calc= MJB FrortDoorfaces: S Page 1 L_ Entire House 1535 17574 22126 1167 i 1167 Other equip loads 0 1707 Equip. @ 1.00 RSM 23832 Latent cooling 8426 Tl1TA1 C 4G4G -1•797A '277io 11927 11R7 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .: -*- wrigghtsoft® 2017-Dec-0614:27,04 I.>a . • N -• Right SL te®Uriversal201818.0.04 RSU16998 .bitatfor Hunan PSL\7803 James Street#2 Page 2 ty .nlp CaIc=MJ8 FrartDoorfaces: S -�- wrightsofts Project Summary Entire House WebREPS, LLC Job: 7803 James Street Date: June 28, 2017 By. Josh Putrnan Plan: 7803 James Street 1892 Commerce Avenue, Vero Beach. FL 32960 Phone: 800-810-3280 Fax 886-971-2999 Emait: sales@webrepshveccom Web: wwwwebrepswholesale.com License: CAC054709 Project Information For. Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft Pierce, FL 34947 Phone: 772-460-6336 Notes: 7803 James Street Ft Pierce FL Design Information Weather. Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 13553 Btuh Ducts 4021 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 17574 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Coolingg Area (ft2) 1535 1535 Volume (ft3) 12283 12283 Air changesthour 0.26 0.14 Equiv. AVF (cfm) 53 29 Heating Equipment Summary Make Goodman Trade Heat Strip Model AHRI ref Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 grAb Sensible Cooling Equipment Load Sizing Structure 15162 Btuh Ducts 6964 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 1707 Btuh Use manufacturer's data y Rate/swin multiplier 1.00 Equipmensensible load 23832 Btuh Latent Cooling Equipment Load Sizing Structure 6556 Btuh Ducts 1870 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 8426 Btuh Equipment Total Load (Sen+Lat) 32259 Btuh Req. total capacity at 0.70 SHR 2.8 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160361F Coil ASPT42D14A AHRI ref 5756175 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 8.0 kW Sensible cooling 24500 Btuh Heating output 27297 Btuh Latentcooling 10500 Btuh Temperature rise 21 OF Total cooling 35000 Btuh Actual airflow 1167 cfm Actual airflow 1167 cfrn Air flow factor 0.066 cfmA3tuh Air flow factor 0.053 tfmA3tuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.74 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Of&- wrightsoft- 2017-Dec0614:27:04 ^� •• �m-� Right-Suite@Uriversal20l8l8.0.04RSU16998 Page 1 ACCK..bitatforHunarityPSL\7803James Street#2np Ca1c=MJ8 FrortDoorfaoes: S Job M 7803 James Street WebREPS, LLC Scale: 1 :73 Performed by Josh Putman for: Page 1 Joe Gonna 1892 CommeroeAvenue RghtSufte®Universal 2018 2904 Okeechobee Road Vero Beach, FL 32960 18.0.04 RSU16998 R. Pierce, FL34947 Phone: 800-810-3280 Fax: 888-971-2999 20174)ec-0615:46:04. Phone:772-460-6336 wwwwebrepswholesale.00m sales@webrepshvaccorn •••kyPSL%7803Jams Street #2.rup - - wrightsofte Duct System Summary Entire House WebREPS, LLC Job: 7803 James Street Date: June 28, 2017 By. Josh Putman Plan: 7803 James Street 1892 Commerce Avenue, Vero Beads, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac oom Web: www.webrepsvAulesale.com Ucerne: CAC054709 Project• • For. Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft. Pierce, FL 34947 Phone: 772-460-6336 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.24 in H2O 0.24 in H2O Available static pressure 0.36 in H2O 0.36 in H2O Supply / return available pressure 0.225 / 0.135 in H2O 0.225 / 0.135 in H2O Lowest friction rate 0.082 in/100ft 0.082 in/100ft Actual airflow 1167 cfm 1167 cfm Total effective length (TEL) 439 ft SupplyDetail Table Name Design (Btuh) Htg (cfrn) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 2157 143 56 0.091 6.0 Ox0 VIFx 18.2 230.0 st3 Bath h 1196 79 57 0.082 5.0 Ox0 VIFx 34.9 240.0 s12 Bed 1 c 2999 152 158 0.091 7.0 Ox 0 VIFx 18.1 230.0 st3 Bed 2 h 3477 231 158 0.086 8.0 Ox 0 VIFx 31.1 230.0 st4 Bed 3 h 2968 197 155 0.085 8.0 Ox 0 VIFx 31.6 235.0 st2 Uring Rm c 2258 80 119 0.085 6.0 Ox 0 VIFx 25.7 240.0 st3 Kitchen c 3741 84 197 0.084 7.0 Ox 0 VIFx 32.7 235.0 W Ling Rm c 2520 100 133 0.086 6.0 Ox 0 VIFx 26.6 235.0 st4 Living wTMA c 2520 100 133 0.088 6.0 Ox 0 VI Fx 25.5 230.0 st4 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 1167 1167 0.082 700 16.0 12 x 20 RectFbg It1 st2 PeakAVF 360 409 0.082 521 12.0 0 x 0 VinIFIX st4 PeakAVF 431 424 0.086 549 12.0 0 x 0 VinIFIX st1 st3 PeakAVF 375 334 0.085 688 10.0 0 x 0 VinIFIX 41 i -�- wrightsoft ° ��•������wm.-.,�w�, Right Sute®Uriversa1201818.0.04 RSU16998 bitatfbrHunarityPSL17803JamesStreet#2rup Calc=MJ8 FrordDoor faces: S 2017-Dec-0614:27:04 Page 1 Name Grille Size (in) Htg (dim) Clg (cfm) TEL M Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 1167 1167 164.1 0.082 660 18.0 Ox 0 MR rt1 Name Trunk Type Htg (tfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 1167 1167 0.082 525 16.0 16 x 20 RectFbg -� wrightsoft- zon-Dea061427:04 CA •.•, Rigtt-Sate®Uriversal201B18.0.04RSU16998 Paget bitatforRimarityPSLX7803Jam esStreet#2.np Calc=MJB Frort Door faoes: S www.pgtindustries.com NFRC Report Quote # PO Num Job Nan Job Add Line # Item Description Quantity 0001 SH5400 VINYL SINGLE HUNG 5400 Ordered: (1.00) . 36.X37.375X.,23,STD,518" FL,W,EQUAL,IG,CL,ES Max,NQ 1.00 GRID,DBL,SWEEP,1816K,CMFRT LIFT HNDL,x. O Number: Certification Type: MIAMI '.k Frame Type:.625FLANGE Window Style: STD _. ._ Size Code: 23.0000 Actual Size: 36 X 37 3/8 Wood Frame: 36114 X 37 5/8 Frame Color. White Glass Family: Insulating -- Argon Gas: NONE Low E: ENERGY SHIELD MAX Grid Type: NO Grid Screen Frame Type: ROLLFORM Boxing Options: None Comfort Lift: Y WOCD: N Reinf. Upgrade: None Upgrade Hardware Finish: N CAR#: 16-0714.04 Neg ativeDesig nPressure: 100.0000 EnergyStar.1.0000 7803 JAMES ST NON IMPACT PPG_L�OiTIMP1 AQT--1 Location WINDOW # 1 NOA Selection: 16-0714.04 Vent Configuration: EQUAL Size Selection: COMMODITY Size Ref: ACTUAL Rough Masonry: 37 3M X 38 3/8 Egress: 31 314 X 14 b11 (3.094 SQFT) Does unit need to meet Turtle Code: NO Glass: 3/4' IG (118 AN-1/2 AIR -1/8 AN) Glass Color. CLEAR Privacy Glass: NONE Screen Type: 1816 Charcoal Anchor Group: A.SH5400 Vent Latch: N Lift Rail: N Lock Type: Sweep Latch Acc.Glass Breakage: N Vent Ht 18.3300 PositiveDesignPressure: 50.0000 PANumber. FL-239 rGondensationResistance: 56.0000 `t,Solad-1 atGain'Coet'0�200 VTC6G:0.6400 i-. - 0002 SH5400 VINYL SINGLE HUNG 5400 Ordered: WINDOW # 2 (2.00) ,.,36.X62.X.,25,STD,5/8" FL,W,EQUAL,IG,CL,ES Max,NO 5.00 GRID,DBL,SWEEP,.1816K,CMFRT LFT HNDL,.x. Print Date 12/412017 Page 1 of 3 Certification Type: MIAMI NOA Selection: 16-0714.04 Frame Type:.625FLANGE Vent Configuration: EQUAL r s Window'Style: STD Size Selection: COMMODITY Size Cotle: 25.0000 Size Ref. ACTUAL Actual Size: 36 X 62 Rough Masonry: 37 3/4 X 63 Wood Frame: 36 1/4 X 62 1/4 Egress: 31 3/4 X 26 318 (5.808 SQFT) Frame Color. White Does unit need to meet Turtle Code: NO Glass Family: Insulating Glass: X' IG (118 AN-1/2 AIR -1/8 AN) •- _ Argon Gas: NONE Glass Color. CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type; NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: A-SH5400 Boxing Options: None Vent Latch: N Comfort Lift: Y U& Rail: N WOCD: N Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent Ht: 30.6430 CAR#: 16-0714.04 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 96.7000 PANumber FL-239 EnermyStar- 1.0000 CondensationResistance: 56.0000 �TF _0 3300 `Vi:-0-4500 SolarHeatGainCoe 0 001 VTCOG_ 66400 0003 SH5400 VINYL SINGLE HUNG 5400 Ordered: WINDOW # 3 (3.00) .,52.125X62.X.,35,STD,5/8" FL,W;EQUAL,IG,CL,ES Max,NO 1.00 GRID,DBL,SWEEP,1816K,CMFRT LFT HNDL,.x" r Certification Type: MIAMI NOA Selection: 16-0714.04 Frame Type.625FLANGE Vent Configuration: EQUAL f Window Style: STD Size Selection: COMMODITY t4 Size Code: 35.0000 Size Ref ACTUAL Actual Size: 521/8 X 62 I ' Wood Frame: 52 3/8 X 62 1/4 b. Rough Masonry: 53 718 X 63 Egress: 47 7/8 X 26 3/8 (8.758 SQ Frame Color. White Does unit need to meet Turtle Code: NO _ I Glass Family: Insulating Glass: 314" IG (1/8 AN-1/2 AIR -118 AN) — - — Argon Gas: NONE Glass Color: CLEAR Low E: ENERGY SHIELD MAX Privacy Glass: NONE Grid Type: NO Grid Screen Type: 1816 Charcoal Screen Frame Type: ROLLFORM Anchor Group: A.SH5400 Boxing Options: None Vent Latch: N Comfort Lift: Y Lift Rail: N WOOD: N Lock Type: Sweep Latch Reinf. Upgrade: None Acc Glass Breakage: N Upgrade Hardware Finish: N Vent tit: 30.6430 CAR#: 16-0714.04 PositiveDesignPressure: 50.0000 NegativeDesignPressure: 56.3000 PANumber. FL-239 Er3ergySta(--A.0000 CondensationBesistance_56 0000 OF D_3300TJSolarHeatGainCoeff<D 22001 VT: 0,4900 VTCOG` 0.6400�V—' 0004 SH5400 VINYL SINGLE HUNG 5400 Ordered: WINDOW # 4 (4.00) ',.,25.5X37.375X.,H33,STD,5/8" FL,W,EQUAL,TIG,CL,ES 2.00 Max,OB,NO GRID;DBL,SWEEP,1816K,CMFRT LFT HNDL,.x. Print Date 12/4/2017 Page 2 of 3 k Certification Type: MIAMI Frame Type:.625FLANGE E Window Style: STD Size Code: H33 E ` Actual Size: 25 112 X 37 3/8 . Wood Frame: 25 314 X 37 5/8 ' t Frame Color White __ 4- Glass Family: Insulating .• _` Tempered Location: UNIT Glass Color: CLEAR Privacy Glass: OBSCURE Grid Type: NO Grid Screen Frame Type: ROLLFORM Boxing Options: None Comfort Lift: Y WOCD: N Reinf. Upgrade: None Upgrade Hardware Finish: N CAR#:16-0714.04 NegativeDesignPressure: 100:0000 Energy,Star. 1.0000 UE 0 3�E1'0. Vr: 0.4900 NOA Selection: 16-0714.04 Vent Configuration: EQUAL Size Selection: COMMODITY Size Ref: ACTUAL Rough Masonry: 27 114 X 38 3/8 Egress: 21 114 X 14 011 (2.071 SQFT) Does unit need to meet Turtle Code: NO Glass: 3X' IG.(118 TMP -112 AIR-1/8 TMP) Argon Gas: NONE Low E: ENERGY SHIELD MAX Privacy Glass Location: UNIT Screen Type: 1816 Charcoal Anchor Group: A-SH5400 Vent Latch: N Lift Rail: N Lock Type-- Sweep. Latch Acc Glass Breakage: N Vent HL• 18.3300 PositiveDesignPressure: 50,0000 PANumber. FL-239 CondensaUonResistance: 56.0000 �o8'Tai}ieat�nCo 00 COG�"OF400 Print Date 12/4/2017 Page 3 of 3