HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
* Building & Code Regulations Division
- -_ - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: HAB - 3BRHC - 7803 James Street
Project Address: 7803 James Street, Fort Pierce, FL 34951
Permit #: Occupancy Type: VB Construction Type: R-3
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit'(2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residence's (single or multi -.family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Residential Code Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): x Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B x C D
4. Design Wind Velocity 170 mph ASD x LRFD End Zone Width: ft
5. Mean Roof Height 10,111, ft Roof Pitch: 4 :12 Parapet:
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on aff:P
Zone 1: -57.65 Zone 2: -100.36 Zone 3: -148.41 Zone 4: -68.33 Zone 5: -84.35 G
7. Design Loads: Floor: PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcon
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? .X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes i
DESIGN PROFESSIONAL CERTIFICATION STATEMENT: .
I certify that, to the best o ji.,yltinyledge and belief, the attached plans & specifications have been designed to
fir..
comply with>.th`e _appli l :tMct7!9Ap,.-
y �,ons of the building codes currently adopted and enforced by St. Lucie
o
County. I also ce s:s�tilt15(rg'1eg'eftdepicted on these plans provide adequate resistance to the design
forces specified , :.- - ,�� �• °�'_ �„
i*16ony Tombo FL. 80083 31615
�j�fiffain�e Cert # & Co. Cert Auth.
e House Engineering, L.L.C.
Ab
1Signature, Date, and••°''��'a�451 St. Lucie Blvd. Fort Pierce, FL 34946
tiros Company Name & Address
I L �- 'Pile COON'
Revised 07/25/2014
3BBCA22100 0000004C1287DIF
i
NOTICE OF PRODUC A CERTIFICATION
Company: JELD-WEN Doors Certification No.: _ NI011233-R2
3737 Lalcesport Drive Certification Date: 08/14/2012
Klamath Falls, OR 97601 Expiration Date: 08/31/2020
Revision Date: 05/16/2016
Product: Contours Steel Opaque Steel Edged Door (w/Wood Frame)
Specification: PA 201-94/202-94/203-94
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification
label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within
NAMI's Certified Product Listing at www.Naniieertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI).
Inswing
Glazed
Design
Water
Missile
Test Report her
Configuration
or
or
Maximum
Pressure
'rest
Impact
Drawing N er &
outswing
Opaque
Size
Pos/Neg,
Pressure
Rated
Com►nf �
X
1/S
Opaque
3'2" x 6' 10"
+80/-80
2.86 psf
Yes
CTLA6560
�C�" �
Single
g
Max Panel Size 6'8"
w/ Kwiksct 700 Latch & DcVXlt� ADA Threshold
Qualifies Conri Mur ti" ns: X
X
O/S
Opaque
3'2" x 6' 10"
+80/-80
12.0 psf
Yes
CTLA650W
Single
Max Panel Size: 3'0" x 6'8"
w/ Kwikset 700 Latch & Deadbolt & Endura 4566A
Threshold
Qualifies Configurations: X
X
I/S
Opaque,
3'2" x 6' 10"
1 80/-80
2.86 psf
Yes
CTLA650W
Single
Max Panel Size: 3'0" x 6'8"
w/ Kwikset 700 Latch & Deadbolt & ADA Threshold
Qualifies Configurations: X
X
O/S
Opaque
37' x 6' 10"
+80/-80
12.0 psf
Yes
CTLA650W
pit."
Single
`Itircj8�t k@Wj jgc Latch & Dcadb[lll V' I
James Street 38RHCIlI`s�l"I`I aw'
l 1i; 111t1Eti \,oflfiI-tilations: '
.�•
- ............._..---...._.._...-..'. ........._.._........ ..._..-...z.-..- -- '
X
O/S
Opaque
3 7' x 6' 10"
-180/-80
12.0 psf
Yes
.,.
0 APPRO\�jb\ 1 find Sizc:.IQ l 666TED
Single
:00 Lall'h &k Dea(lb[)II{k llnherial High Dam
tJ REVISE NOT REVIEWED
Thresh011 l
f�lyy,lilil:•ti 1i:ulJ tz rui-my
BY atombo DATE 12/11/2017
SUBMITTAL# SPEC i
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Hi ►)tt''�V �y•{{���1['",yy��, ±;"r `Jr' "" fj�}% �IU:ep:ojectandllerlual
•.O:�u,f;.",rL,.,Z [jf 1j: rl,{,Tfl,'nt c orl these d:'nwings duting this
Tel: (804) 684-5124/Fax: (804) 684-5122 rt7 liolai:; : <: ,::f a;;lo:: S.:Uconlr�cte: from c,)rnp1ign.a7 wilt) the
u•qui; [;:l;a: d•:.;I thr: ;:6Zr� •.uid ,j rtn;;h;.Zli�::t;.. i:onh atlr:r c; : es;ponsible IRr all
thmensv::': ar ir.7Lri ,nZr: p ba Conli:sled and cnnelaled it the job vita
1'1 NAMI AUTHORIZED SIGNATURE:
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: 7803 James Street
BuilderName: Habitat for Humanity
Street: 7803James Street
Permit Office: 5 L C
City, State, Zip: Ft. Pierce, FL,
PermitNumber: 1710-0531
Owner: Habitat for Humanity
Jurisdiction: Saint Lucie County
DesignLocation: FL, ST LUCIE_CO_INTL
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New(FromPlans)
9. Wall Types (1424.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1182.00 ft2
b. Concrete Block- Int Insul, Adjacent
R=4.1 242.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=, ft2
4. Number of Bedrooms
4
d. N/
_ ft2
5. Is this a worst case?
No
. eiling Types (1536.0 sqft.)
Insula ion r
a. Under Attic (Vented)
2
R=30.0 1536.00�
6. Conditioned floor area above grade (ft�
1536
b. N/A
R= ftZ
Conditionedfloorareabelo
0
c N/A
R= ft2
11. Ducts
2
7. Windows(160.2 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 307
a. U-Factor: Dbl, U=0.33
160.17 ft2
SHGC: SHGC=0.22
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.3 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
1.500 ft.
Area Weighted Average SHGC:
0.220
14. Hot water systems
a. Electric
Cap:40 gallons
8. Floor Types (1535.7 sqft.)
Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation
R=0.0 1535.70ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.104
Total Proposed Modified Loads: 50.95
PASS
Total Baseline Loads: 50.80
I hereby certify that the plans and specifications covered by
Review of the plans and�HE
41, .
this calculation are in compliance wit
he Florida Energy
specifications covered by this
0 c�ik:
Code.
calculation indicates compliance
PREPARED BY:
with the Florida Energy Code.
Before construction is completed
f+n,,'
DATE: 12P_C2n. 6f.f ? ,
Zo I
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building as designed, is in compliance
Florida Statutes.
with the Florida Ener Code.
COD 1qf 1
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 2-
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1. g,�° �0'
- Compliance requires an Air Barrier and Insulation Inspection Checklist in al'cild'ance witfi 402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
12/6/2017 2:58 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title:
7803 James Street
Bedrooms:
4
Address Type:
StreetAddress
Building Type:
User
ConditionedArea:
1536
Lot#
Owner:
Habitat for Humanity
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
BuilderName:
Habitatfor Humanity
RotateAngle:
0
Street:
7803 James Street
Permit Office:
CrossVentilation:
No
County:
St. Lucie
Jurisdiction:
Saint Lucie County
Whole House Fan:
No
City, State, Zip:
Ft. Pierce,
FamilyType:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
Parcel#1301-603-0021-000/1
CLIMATE
j
IECC Design Temp
Int Design Temp
Heating
Design
DailyTemp
v
DesignLocation
TMY Site
Zone 97.5 %
2.5 %
Winter
Summer
Degree Days
Moisture
Range
FL, ST LUCIE CO_INTL FL VERO_BEACH_MUNI
2 39
90
70
75
299
58
Medium
BLOCKS
Number Name
Area
Volume
1
Entire House
1536
12288
SPACES
Number Name
Area
Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled Heated
1
Bed
195
1560
No
1
1
1
Yes
Yes
Yes
2
cist 2
19
149
No
0
1
Yes
Yes
Yes
3
Bath 2
112
896
No
0
1
Yes
Yes
Yes
4
be
16
130
No
0
1
No
Yes
Yes
5
cist 3
17
136
No
0
1
Yes
Yes
Yes
6
Bed 3
197
1576
No
1
1
1
Yes
Yes
Yes
7
Living Rm
336
2685
No
0
1
Yes
Yes
Yes
8
Kitchen
169
1352
Yes
0
1
1
Yes
Yes
Yes
9
Dining Rm
126
1011
No
0
1
Yes
Yes
Yes
10
Ldry
26
210
No
0
1
Yes
Yes
Yes
11
Bed
207
1656
No
2
1
1
Yes
Yes
Yes
12
cist 1
16
126
No
0
1
Yes
Yes
Yes
13
Bath 1
100
802
No
0
1
Yes
Yes
Yes
FLOORS
# FloorType
Space
Perimeter PerimeterR-Value
Area
JoistR-Value Tile Wood I Carpet
1 Slab -On -Grade Edge Insulation
Bed 2
32.3 ft 0
195.2 ftz
----
1 0
0
2 Slab -On -Grade Edge Insulation
clst 2
2.8 ft 0
18.6 ftZ
----
1 0
0
3 Slab -On -Grade Edge Ins ulation
Bath 2
9 ft 0
112 ftZ
----
1 0
0
4Slab-On-Grade Edge Insulation
be
1 ft 0
16.3ft2
----
1 0
0
12/6/2017 2:58 PM EnergyGauge®USA -FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
clst 3 2.5 ft
0
16.9 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulation
Bed 3 26.8 ft
0
196.9 ft2
----
1
0
0
7 Slab -On -Grade Edgelnsulation
Living Rm 16.5 ft
0
335.6 ft2
----
1
0 '
0
8Slab-On-Grade Edge Insulation
Kitchen 11.3ft
0
168.8ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
Dining Rm 6.5 ft
0
126.4 ft2
_---
1
0
0
10SIab-0n-Grade Edge Insulation
Ldry 3.5 It
0
26.3 ftz
____
1
0
0
11SIab-On-Grade Edge Insulation
Bed 1 14.3 ft
0
206.6 ft2
_---
1
0
0
12SIab-On-Grade Edge Insulation
clst 1 2.3 ft
0
15.8 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
Bath 20.3ft
0
100.3ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck;
Pitch
�/ # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Compositionshingles 1618 ft2
256 ft2
Medium
0.9
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
300
1535 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 UnderAttic (Vented)
Bed 2
30
Blown
195 ft2
0.1
Wood
2 UnderAttic (Vented)
clst 2
30
Blown
19 ft2
0.1
Wood
3 UnderAttic (Vented)
Bath 2
30
Blown
112 ft2
0.1
Wood
4 UnderAttic(Vented)
be
30
Blown
16ft2
0.1
Wood
5 UnderAttic (Vented)
clst 3
30
Blown
17 ft2
0.1
Wood !
6 UnderAttic (Vented)
Bed 3
30
Blown
197 ft2
0.1
Wood
7 UnderAttic (Vented)
Living Rm
30
Blown
336 ft2
0.1
Wood
8 UnderAttic (Vented)
Kitchen
30
Blown
169 ft2
0.1
Wood
9 UnderAttic (Vented)
Dining Rm
30
Blown
126 ft2
0.1
Wood
10 UnderAttic (Vented)
Ldry
30
Blown
26ft2
0.1
Wood
11 UnderAttic (Vented)
Bed
30
Blown
207ft2
0.1
Wood
12 UnderAttic (Vented)
clst 1
30
Blown
16 ft2
0.1
Wood
13 UnderAttic(Vented)
Bath
30
Blown
100ft2
0.1
Wood
12/6/2017 2:58 PM EnergyGauge® USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Below
10
WWII\=Space
hle
Fraction
Ahsn
1
N
Exterior
Concrete Block- Int Insul
Bed 2
4.1
14
3
8 0
114.0 ft2
0
0
0.6
0
2
E
Exterior
Concrete Block- Int Insul
Bed 2
4.1
5
9
8 0
46.0 ft2
0
0
0.6
0
3
W
Exterior
Concrete Block - Int Insul
Bed 2
4.1
12
3
8 0
98.0 ft2
0
0
0.6
0
4
W
Exterior
Concrete Block - Int Insul
clst 2
4.1
2
9
8 0
22.0 ft2
0
0
0.6
0
5
W
Exterior
Concrete Block- Int Insul
Bath 2
4.1
9
0
8 0
72.0 ft2
0
0
0.6
0
6
W
Exterior
Concrete Block- Int Insul
cast 3
4.1
2
6
8 0
20.0 ft2
0
0
0.6
0
7
S
Exterior
Concrete Block- Int Insul
Bed 3
4.1
14
3
8 0
114.0 ft2
0
0
0.6
0
8
W
Exterior
Concrete Block - Int Insul
Bed 3
4.1
12
6
8 0
100.0 ft2
0
0
0.6
0
9
N
Exterior
Concrete Block- Int Insul
Living Rm
4.1
16
6
8 0
132.0 ft2
0
0
0.6
0
10
E
Garage
Concrete Block - Int Insul
Living Rm
4.1
11
0
8 0
88.0 ft2
0
0
0.6
0
_ 11
N
Garage
Concrete Block- Int Insul
Living Rm
4.1
4
9
8 0
38.0 ft2
0
0
0.6
0
12
S
Exterior
Concrete Block- Int Insul
Kitchen
4.1
11
3
8 0
90.0 ft2
0
0
0.6
0
13
S
Exterior
Concrete Block- Int Insul
Dining Rm
4.1
6
6
8 0
52.0 ft2
0
0
0.6
0
14
S
Exterior
Concrete Block- Int Insul
Ldry
4.1
3
6
8 0
28.0 ft2
0
0
0.6
0
15
E
Exterior
Concrete Block- Int Insul
Bed 1
4.1
14
3
8 0
114.0 ft2
0
0
0.6
0
16
N
Garage
Concrete Block- Int Insul
Bed 1
4.1
14
6
8 0
116.0 ft2
0
0
0.6
0
17
E
Exterior
Concrete Block- Int Insul
clst 1
4.1
2
3
8 0
18.0 ft2
0
0
0.6
0
18
E
Exterior
Concrete Block- Int Insul
Bath 1
4.1
5
9
8 0
46.0 ft2
0
0
0.6
0
19
S
Exterior
Concrete Block - Int Insul
Bath 1
4.1
14
6
8 0
116.0 ft2
0
0
0.6
0
DOORS
#
Ornt
DoorType
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Living Rm
None
.39
3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes
NFRC
U-Factor
SHGC
Area
Depth
Separation
IntShade
Screening
1
N 1
None Low-EDouble
Yes
0.33
0.22
17.5 ft2
1 ft 6 in
1 ft 0 in
None
None
2
W 3
None Low-EDouble
Yes
0.33
0.22
17.5 ft2
1 ft 6 in
1 ft 0 in
None
None
3
W 5
None Low-EDouble
Yes
0.33
0.22
7.5 ft2
1 ft 6 in
1 ft 0 in
None
None
4
S 7
None Low-EDouble
Yes
0.33
0.22
17.5 ft2
1 ft 6 in
1 ft 0 in
None
None
5
W 8
None Low-EDouble
Yes
0.33
0.22
17.5 ft2
1 ft 6 in
1 ft 0 in
None
None
6
N 9
None Low-EDouble
Yes
0.33
0.22
26.7 ft2
1 ft 6 in
1 ft 0 in
None
None
7
S 12
None Low-EDouble
Yes
0.33
0.22
10.5 ft2
1 ft 6 in
1 ft 0 in
None
None
8
S 13
None Low-EDouble
Yes
0.33
0.22
20.5 ft2
1 ft 6 in
1 ft 0 in
None
None
9
E 15
None Low-EDouble
Yes
0.33
0.22
17.5 ft2
1 ft 6 in
1 ft 0 in
None
None
10
S 19
None Low-EDouble
Yes
0.33
0.22
7.5 ft2
1 ft 6 in
1 ft 0 in
Drapes/Winds
Exterior5
12/6/2017 2:58 PM EnergyGauge®USA- FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
GARAGE
#
FloorArea CeilingArea
ExposedWall Perimeter Avg.WallHeight Exposed Wall Insulation
1
382.8 ft'
384 ft2
64 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
ProposedACH(50)
.000254
1024.1 56.22 105.73 .1906 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None
COPA 27.3 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split
SEER: 16 35 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.92 40gal 60.9gal 120deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # CompanyName
Collector Storage
System Model# CollectorModel# Area Volume
FEF
None
None
ftz
DUCTS
#
— Supply—
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area LeakageType Handier TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 307 ftZ
Attic
77 ftZ DefaultLeakage Attic (Default) c(Default) c
1 1
12/6/2017 2:58 PM EnergyGauge® USA -FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
i
FnRnn Rangy-gnlA
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans:
CoolingHJan
HeatinJan
Feb
HFeb
Mar
MMar
�Apr
Ar
I
Ma
May
Jun
Jun
Jul
Jul
u
u
Mug
Se
Sep
Oct
Oct
MNOV
Nov
Dec
Dec
Ventin Jan
Feb
Mar
A r
May
Jun
Jul
Se
[X] Oct
Nov
Dec
ThermostatSchedule:
HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
.65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
l
12/6/2017 2:58 PM EnergyGauge®USA- FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
I
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
7803 James Street, Ft. Pierce, FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.1
1182.00 ftz
b. Concrete Block - Int Insul, Adjacent R=4.1
242.00 ftz
3. Number of units, if multiple family
1 c. N/A R=
ftz
4. Number of Bedrooms
4 d. N/A R=
ftz
5. Is this a worst case?
No 10. Ceiling Types Insulation
Area
a. Under Attic (Vented) R=30.0
1536.00 ftz
6. Conditioned floor area (ftz)
1536 b. N/A R=
ftz
7. Windows- Description
. N/Aucts R_
Area
z
a. U-Factor: Dbl, U=0.33
11.
160.17 ftz a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 307
SHGC: SHGC=0.22
b. U-Factor: N/A
ftz
SHGC:
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: N/A
ftz a. Central Unit 35.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ftz
SHGC:
13. Heating systems kBtu/hr
Efficiency
a. Electric Strip Heat 27.3
COP:1.00
Area Weighted Average Overhang Depth:
1.500 ft.
Area Weighted Average SHGC:
0.220
8. Floor Types Insulation
Area 14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0 1535.70 ftz a. Electric Cap: 40 gallonsEF:
0.92
b. N/A R=
ftz
c. N/A R=
ftz b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see, the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
12/6/2017 2:58 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
- wrightsoft®
Load Short Form
Entire House
WebREPS, LLC
Job:
7803 James Street
Date:
June 28, 2017
By:
Josh Putman
Plan:
7803 James Street
1892 Commerce Averue, Vero Beads, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepdwaccom Web: vwaw.webrepswholesale.com License: CAC054709
For. Joe Gianna, Habitat for Humanity
2904 Okeechobee Road, Ft Pierce, FL 34947
Phone: 772-460-6336
'Design In• •
Htg Clg Infiltration
Outside db (°F) 43 91 Method Simplified
Inside db (°F) 70 75 Construction quality Semi -tight
Design TD (°F) 27 16 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gdlb) 0 59
HEATING EQUIPMENT
Make Goodman
Trade Heat Strip
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.0
kW
27297
Btuh
21
°F
1167
cfm
0.066
cfmBtuh
0.60
in H2O
COOLING EQUIPMENT
Make
Goodman Mfg.
Trade
GOODMAN
Cond
GSX160361F
Coil
ASPT42D14A
AHRI ref
5756175
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual airflow
Airflowfactor
Static pressure
Load sensible heat ratio
13.0 EER, 16 SEER
24500
Btuh
10500
Btuh
35000
Btuh
1167
cfm
0.053
cfmBtuh
0.60
in H2O
0.74
ROOM NAME
Area
M
Htg load
(Btuh)
Clg load
(tuh)
Htg AVF
(cfirn)
CIgAVF
(ulli)
Bed 2
195
3477
3000
231
158
cast 2
19
0
0
0
0
Bath 2
112
1196
1085
79
57
be
16
0
0
0
10
clst 3
17
0
0
0
10
Bed 3
197
2968
2933
197
155
Living Rm
336
3019
5040
200
266
Kitchen
169
1259
3741
84
197
Dining Rm
126
1207
2258
80
119
Ldry
26
0
0
0
1 0
Bed 1
207
2290
2999
152
158
clst 1
16
0
0
0
0
Bath 1
100
2157
1071 Vjje C
56
I
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft-
2017-Deo-0614:27:04
AM,,..• wte w« gym, Right Sute® Uriversal 201818.0.04 RSU16998
.bitaMr Hunarity PSL%7803 James Street#2np Calc= MJB FrortDoorfaces: S
Page 1
L_
Entire House
1535
17574
22126
1167
i
1167
Other equip loads
0
1707
Equip. @ 1.00 RSM
23832
Latent cooling
8426
Tl1TA1 C
4G4G
-1•797A
'277io
11927
11R7
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.: -*- wrigghtsoft® 2017-Dec-0614:27,04
I.>a . • N -• Right SL te®Uriversal201818.0.04 RSU16998
.bitatfor Hunan PSL\7803 James Street#2 Page 2
ty .nlp CaIc=MJ8 FrartDoorfaces: S
-�- wrightsofts Project Summary
Entire House
WebREPS, LLC
Job:
7803 James Street
Date:
June 28, 2017
By.
Josh Putrnan
Plan:
7803 James Street
1892 Commerce Avenue, Vero Beach. FL 32960 Phone: 800-810-3280 Fax 886-971-2999 Emait: sales@webrepshveccom Web: wwwwebrepswholesale.com License: CAC054709
Project Information
For. Joe Gianna, Habitat for Humanity
2904 Okeechobee Road, Ft Pierce, FL 34947
Phone: 772-460-6336
Notes: 7803 James Street Ft Pierce FL
Design Information
Weather. Vero Beach Muni, FL, US
Winter Design Conditions
Outside db 43 OF
Inside db 70 OF
Design TD 27 OF
Heating Summary
Structure
13553 Btuh
Ducts
4021 Btuh
Central vent (0 cfm)
0 Btuh
(none)
Humidification
0 Btuh
Piping
0 Btuh
Equipment load
17574 Btuh
Infiltration
Method
Simplified
Construction quality
Semi -tight
Fireplaces
0
Heating Coolingg
Area (ft2)
1535
1535
Volume (ft3)
12283
12283
Air changesthour
0.26
0.14
Equiv. AVF (cfm)
53
29
Heating Equipment Summary
Make Goodman
Trade Heat Strip
Model
AHRI ref
Summer Design Conditions
Outside db
91
OF
Inside db
75
OF
Design TD
16
OF
Daily range
L
Relative humidity
50
%
Moisture difference
59
grAb
Sensible Cooling Equipment Load
Sizing
Structure
15162
Btuh
Ducts
6964
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
1707
Btuh
Use manufacturer's data y
Rate/swin multiplier 1.00
Equipmensensible load 23832 Btuh
Latent Cooling Equipment Load Sizing
Structure
6556
Btuh
Ducts
1870
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
8426
Btuh
Equipment Total Load (Sen+Lat)
32259
Btuh
Req. total capacity at 0.70 SHR
2.8
ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN
Cond GSX160361F
Coil ASPT42D14A
AHRI ref 5756175
Efficiency
100 EFF
Efficiency
13.0 EER,16 SEER
Heating Input
8.0
kW
Sensible cooling
24500
Btuh
Heating output
27297
Btuh
Latentcooling
10500
Btuh
Temperature rise
21
OF
Total cooling
35000
Btuh
Actual airflow
1167
cfm
Actual airflow
1167
cfrn
Air flow factor
0.066
cfmA3tuh
Air flow factor
0.053
tfmA3tuh
Static pressure
0.60
in H2O
Static pressure
0.60
in H2O
Space thermostat
Load sensible heat ratio
0.74
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Of&- wrightsoft- 2017-Dec0614:27:04
^� •• �m-� Right-Suite@Uriversal20l8l8.0.04RSU16998 Page 1
ACCK..bitatforHunarityPSL\7803James Street#2np Ca1c=MJ8 FrortDoorfaoes: S
Job M 7803 James Street WebREPS, LLC Scale: 1 :73
Performed by Josh Putman for: Page 1
Joe Gonna 1892 CommeroeAvenue RghtSufte®Universal 2018
2904 Okeechobee Road Vero Beach, FL 32960 18.0.04 RSU16998
R. Pierce, FL34947 Phone: 800-810-3280 Fax: 888-971-2999 20174)ec-0615:46:04.
Phone:772-460-6336 wwwwebrepswholesale.00m sales@webrepshvaccorn •••kyPSL%7803Jams Street #2.rup
- - wrightsofte Duct System Summary
Entire House
WebREPS, LLC
Job:
7803 James Street
Date:
June 28, 2017
By.
Josh Putman
Plan:
7803 James Street
1892 Commerce Avenue, Vero Beads, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac oom Web: www.webrepsvAulesale.com Ucerne: CAC054709
Project• •
For. Joe Gianna, Habitat for Humanity
2904 Okeechobee Road, Ft. Pierce, FL 34947
Phone: 772-460-6336
Heating
Cooling
External static pressure
0.60
in H2O
0.60 in H2O
Pressure losses
0.24
in H2O
0.24 in H2O
Available static pressure
0.36
in H2O
0.36 in H2O
Supply / return available pressure
0.225 / 0.135
in H2O
0.225 / 0.135 in H2O
Lowest friction rate
0.082
in/100ft
0.082 in/100ft
Actual airflow
1167
cfm
1167 cfm
Total effective length (TEL)
439 ft
SupplyDetail
Table
Name
Design
(Btuh)
Htg
(cfrn)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath
h 2157
143
56
0.091
6.0
Ox0
VIFx
18.2
230.0
st3
Bath
h 1196
79
57
0.082
5.0
Ox0
VIFx
34.9
240.0
s12
Bed 1
c 2999
152
158
0.091
7.0
Ox 0
VIFx
18.1
230.0
st3
Bed 2
h 3477
231
158
0.086
8.0
Ox 0
VIFx
31.1
230.0
st4
Bed 3
h 2968
197
155
0.085
8.0
Ox 0
VIFx
31.6
235.0
st2
Uring Rm
c 2258
80
119
0.085
6.0
Ox 0
VIFx
25.7
240.0
st3
Kitchen
c 3741
84
197
0.084
7.0
Ox 0
VIFx
32.7
235.0
W
Ling Rm
c 2520
100
133
0.086
6.0
Ox 0
VIFx
26.6
235.0
st4
Living wTMA
c 2520
100
133
0.088
6.0
Ox 0
VI Fx
25.5
230.0
st4
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st1
PeakAVF
1167
1167
0.082
700
16.0
12 x 20
RectFbg
It1
st2
PeakAVF
360
409
0.082
521
12.0
0 x 0
VinIFIX
st4
PeakAVF
431
424
0.086
549
12.0
0 x 0
VinIFIX
st1
st3
PeakAVF
375
334
0.085
688
10.0
0 x 0
VinIFIX
41
i
-�- wrightsoft °
��•������wm.-.,�w�, Right Sute®Uriversa1201818.0.04 RSU16998
bitatfbrHunarityPSL17803JamesStreet#2rup Calc=MJ8 FrordDoor faces: S
2017-Dec-0614:27:04
Page 1
Name
Grille
Size (in)
Htg
(dim)
Clg
(cfm)
TEL
M
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb2
Ox 0
1167
1167
164.1
0.082
660
18.0
Ox 0
MR
rt1
Name
Trunk
Type
Htg
(tfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
rt1
PeakAVF
1167
1167
0.082
525
16.0
16 x 20
RectFbg
-� wrightsoft- zon-Dea061427:04
CA •.•, Rigtt-Sate®Uriversal201B18.0.04RSU16998 Paget
bitatforRimarityPSLX7803Jam esStreet#2.np Calc=MJB Frort Door faoes: S
www.pgtindustries.com
NFRC Report
Quote #
PO Num
Job Nan
Job Add
Line # Item Description Quantity
0001 SH5400 VINYL SINGLE HUNG 5400 Ordered:
(1.00) . 36.X37.375X.,23,STD,518" FL,W,EQUAL,IG,CL,ES Max,NQ 1.00
GRID,DBL,SWEEP,1816K,CMFRT LIFT HNDL,x. O Number:
Certification Type: MIAMI
'.k Frame Type:.625FLANGE
Window Style: STD
_. ._ Size Code: 23.0000
Actual Size: 36 X 37 3/8
Wood Frame: 36114 X 37 5/8
Frame Color. White
Glass Family: Insulating
-- Argon Gas: NONE
Low E: ENERGY SHIELD MAX
Grid Type: NO Grid
Screen Frame Type: ROLLFORM
Boxing Options: None
Comfort Lift: Y
WOCD: N
Reinf. Upgrade: None
Upgrade Hardware Finish: N
CAR#: 16-0714.04
Neg ativeDesig nPressure: 100.0000
EnergyStar.1.0000
7803 JAMES ST NON IMPACT
PPG_L�OiTIMP1 AQT--1
Location
WINDOW # 1
NOA Selection: 16-0714.04
Vent Configuration: EQUAL
Size Selection: COMMODITY
Size Ref: ACTUAL
Rough Masonry: 37 3M X 38 3/8
Egress: 31 314 X 14 b11 (3.094 SQFT)
Does unit need to meet Turtle Code: NO
Glass: 3/4' IG (118 AN-1/2 AIR -1/8 AN)
Glass Color. CLEAR
Privacy Glass: NONE
Screen Type: 1816 Charcoal
Anchor Group: A.SH5400
Vent Latch: N
Lift Rail: N
Lock Type: Sweep Latch
Acc.Glass Breakage: N
Vent Ht 18.3300
PositiveDesignPressure: 50.0000
PANumber. FL-239
rGondensationResistance: 56.0000
`t,Solad-1 atGain'Coet'0�200
VTC6G:0.6400 i-. -
0002 SH5400 VINYL SINGLE HUNG 5400 Ordered: WINDOW # 2
(2.00) ,.,36.X62.X.,25,STD,5/8" FL,W,EQUAL,IG,CL,ES Max,NO 5.00
GRID,DBL,SWEEP,.1816K,CMFRT LFT HNDL,.x.
Print Date 12/412017
Page 1 of 3
Certification Type: MIAMI
NOA Selection: 16-0714.04
Frame Type:.625FLANGE
Vent Configuration: EQUAL
r s Window'Style: STD
Size Selection: COMMODITY
Size Cotle: 25.0000
Size Ref. ACTUAL
Actual Size: 36 X 62
Rough Masonry: 37 3/4 X 63
Wood Frame: 36 1/4 X 62 1/4
Egress: 31 3/4 X 26 318 (5.808 SQFT)
Frame Color. White
Does unit need to meet Turtle Code: NO
Glass Family: Insulating
Glass: X' IG (118 AN-1/2 AIR -1/8 AN)
•- _ Argon Gas: NONE
Glass Color. CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Grid Type; NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: A-SH5400
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
U& Rail: N
WOCD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Upgrade Hardware Finish: N
Vent Ht: 30.6430
CAR#: 16-0714.04
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 96.7000
PANumber FL-239
EnermyStar- 1.0000
CondensationResistance: 56.0000
�TF _0 3300
`Vi:-0-4500
SolarHeatGainCoe 0 001
VTCOG_ 66400
0003 SH5400 VINYL SINGLE HUNG 5400
Ordered: WINDOW # 3
(3.00) .,52.125X62.X.,35,STD,5/8" FL,W;EQUAL,IG,CL,ES Max,NO
1.00
GRID,DBL,SWEEP,1816K,CMFRT LFT HNDL,.x"
r Certification Type: MIAMI
NOA Selection: 16-0714.04
Frame Type.625FLANGE
Vent Configuration: EQUAL
f Window Style: STD
Size Selection: COMMODITY
t4 Size Code: 35.0000
Size Ref ACTUAL
Actual Size: 521/8 X 62
I ' Wood Frame: 52 3/8 X 62 1/4
b.
Rough Masonry: 53 718 X 63
Egress: 47 7/8 X 26 3/8 (8.758 SQ
Frame Color. White
Does unit need to meet Turtle Code: NO
_ I Glass Family: Insulating
Glass: 314" IG (1/8 AN-1/2 AIR -118 AN)
— - — Argon Gas: NONE
Glass Color: CLEAR
Low E: ENERGY SHIELD MAX
Privacy Glass: NONE
Grid Type: NO Grid
Screen Type: 1816 Charcoal
Screen Frame Type: ROLLFORM
Anchor Group: A.SH5400
Boxing Options: None
Vent Latch: N
Comfort Lift: Y
Lift Rail: N
WOOD: N
Lock Type: Sweep Latch
Reinf. Upgrade: None
Acc Glass Breakage: N
Upgrade Hardware Finish: N
Vent tit: 30.6430
CAR#: 16-0714.04
PositiveDesignPressure: 50.0000
NegativeDesignPressure: 56.3000
PANumber. FL-239
Er3ergySta(--A.0000
CondensationBesistance_56 0000
OF D_3300TJSolarHeatGainCoeff<D
22001
VT: 0,4900
VTCOG` 0.6400�V—'
0004 SH5400 VINYL SINGLE HUNG 5400
Ordered: WINDOW # 4
(4.00) ',.,25.5X37.375X.,H33,STD,5/8" FL,W,EQUAL,TIG,CL,ES
2.00
Max,OB,NO GRID;DBL,SWEEP,1816K,CMFRT LFT HNDL,.x.
Print Date 12/4/2017
Page 2 of 3
k
Certification Type: MIAMI
Frame Type:.625FLANGE
E
Window Style: STD
Size Code: H33
E `
Actual Size: 25 112 X 37 3/8
.
Wood Frame: 25 314 X 37 5/8
' t
Frame Color White
__ 4-
Glass Family: Insulating
.• _`
Tempered Location: UNIT
Glass Color: CLEAR
Privacy Glass: OBSCURE
Grid Type: NO Grid
Screen Frame Type: ROLLFORM
Boxing Options: None
Comfort Lift: Y
WOCD: N
Reinf. Upgrade: None
Upgrade Hardware Finish: N
CAR#:16-0714.04
NegativeDesignPressure: 100:0000
Energy,Star. 1.0000
UE 0 3�E1'0.
Vr: 0.4900
NOA Selection: 16-0714.04
Vent Configuration: EQUAL
Size Selection: COMMODITY
Size Ref: ACTUAL
Rough Masonry: 27 114 X 38 3/8
Egress: 21 114 X 14 011 (2.071 SQFT)
Does unit need to meet Turtle Code: NO
Glass: 3X' IG.(118 TMP -112 AIR-1/8 TMP)
Argon Gas: NONE
Low E: ENERGY SHIELD MAX
Privacy Glass Location: UNIT
Screen Type: 1816 Charcoal
Anchor Group: A-SH5400
Vent Latch: N
Lift Rail: N
Lock Type-- Sweep. Latch
Acc Glass Breakage: N
Vent HL• 18.3300
PositiveDesignPressure: 50,0000
PANumber. FL-239
CondensaUonResistance: 56.0000
�o8'Tai}ieat�nCo 00
COG�"OF400
Print Date 12/4/2017
Page 3 of 3