HomeMy WebLinkAboutInspection Docs Q _
Planning &Development Services FLujcUie
IVED
Building &Code Regulation Division
* e 2300 Virginia Ave 0 2019
• Fort Pierce,FL 34982
772-462-2172 Fax 772-462-6443 nty, Permitting
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
PERMIT #: I?/() - OS57 JOB ADDRESS: SZOZ P:,► e--ree
BUILDER/CONTRACTOR: 6 LALDI k -.1 1j6Tr
PEST CONTROL CONTRACTOR: f
PEST CONTROL LICENSE #: 183 1,0
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 1i 20© Chemicals used: GroSS «I eC-r
Percentage of solution: 010-6°o Total gallons used: 5'fo
Date of Treatment: '7 Time of Tr ent: ( Q'j S 6R
Footing Slab
1st Treatment ijTreatment
Re jrreat Re--Treat
Driveway Pools
1st Treatment -1st Treatment
Re-Treat Re-Treat
Other y Perimeter for Final In on
1�Treatment _
Re Treat /7-0/
Signature of Exterminator D to
Note.- There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re inspection
fee charged.
FBC104.2.6 Certificate ofProtecdve Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment Is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment,
Certificate shall provide the product used,identity of the applicator, time and date of the treatment,site location,area
treated, chemical used,percent concentration and number ofgallons used, to establish a ven able record of
protective treatment If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO,a Permanent Sticker to be placed on .
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
I
' I I
_- Planning &Development Services
Building &Code Regulation Division
MON0. 2300 Virginia Ave
wmt Fort Pierce, FL 34982
- - -- --- - 772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT j
CONSTRUCTION SOIL TREATMENT
PERMIT # 0 5-J"I JOB ADDRESS: 5202 Pinetree Dr,
Fort Pierce,FL 34982 BUILDER/CONTRACTOR:
6-1_Pau4v- s 56?-7 ,lawUr PL- PEST CONTROL
CONTRACTOR: Trusty's Pest control PEST CONTROL!
LICENSE #: JB183203
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 1,200 Chemicals used: upstar Gold
Percentage of solution: 0.06% Total gallons used: 120
Date of Treatment: 02/09/2018 Time of Treatment: 2:45 pm
Footing Slab
X" 1s*Treatment XXX 1st Treatment
Re-Treat Re Treat
Driveway Pools
1st Treatment 15t Treatment
Re-Treat Re-Treat
Other Perimeter for Final Inspection
1st Treatment ^ram
Re Treat `
Signature of Exterminator
Note. There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re inspection
fee charged.
FBC104.2.6 CerVflcate of Protective Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used,percent concentration and number ofgallons used, to establish a verifiable record of
protective treatment. Ifffi&soil chemical barrier method for termite prevention is used, final exterior treatmentshail
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on'
the electrical panel box cover, listing all the treatments and dates of applications.
i
Soil Nuclear Gauge Client: Project:
Report Date:2/972018 Kurt Jett- -- -- --- — ----- 18-4096.00---- -- - - - - -
Test Method:ASTM D 6938 _ 5202 Pinetree Drive 5202_Pi netree Drive, Fort Pierce
��a"^Lucie
Port St.Lucie Fort Pierce, FL 34982
FBPE CA#4930
607 NW Commodity cove
Port St.Lucie,FL 34986 A
Phone:772-924-3575 1 Fax:772-924-3580 Q
Test Results
Optimum Maximum In Place In Place Probe Min/Max
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp.
Test# Of Date Proctor ID Method Classification M (pcf) M (pcf) (in) Compaction M Remark
1 2/7/18 P-1 N/A 10.0 112.0 9.4 109.8 12 98 951105 Pass
2 2/7/18 P-1 N/A 10.0 112.0 9.1 110.6 12 99 95/105 Pass
3 2/7118 P-1 N/A 10.0 112.0 9.3 110.2 12 98 95/105 Pass
Test Information
Gauge
Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician
1 Below Slab Grade:Garage Addition,Southeast Section 0-1 Troxler/3440/27976/ Smith,Johnnie
2 Below Slab Grade:Garage Addition,Northwest Section 0-1 Troxler/3440/27976/ Smith,Johnnie
3 Below Slab Grade:Garage Addition,Center section 0-1 Troxler 13440/27976/ Smith,Johnnie
Remarks I Comments
Pass:Tests results comply with specifications Tests are"Direct Transmission"(Method A)unless probe depth is noted as
"Backscatter".Gauge calibration data on file with the testing agency.
---- RECEIVED
FED 12 2018
ST. Lucie County, Permitting
%%%`%So"N KFNT��i
- No
02/09/2018
Joh K:ent E.
' O �'
STATE �rofe g9$� l Engineer#63218
'����'•.< O R t p t'�ielorida
1111iII11011 A I.)C? o P O
VED
Test Reports shall not be reproduced, except in full,without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.