HomeMy WebLinkAboutNotice of Acceptance MIAMI•DADE MIAMI-DADS COINTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33 t75-2474 130ARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 r(786)315-2599 NOTICE OF ACCEPTANCE (NOA) wivw.minmidade.gov/economy James Hardie Building Product,Inc. 10901 Elm Avenue Fontana,CA 92337 SCOPE: This NOA is being issued under the applicable riles and regulations governing the use of construction materials.The j documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: "Hardie", "Cem" and "Prevail"Planks and Panels Fiber Cement Siding and Soffit APPROVAL DOCUMENT:Drawing No.PNL,PLK&SOFF,titled"HardiePanel,CemPanel,Prevail Panel;HardiePlank,CemPlank Prevail Lap Siding;HardieSoffit,CetnSoffit Panel;Installation Details Wood/Metal Stud Construction",sheets 1 through 12 of 12,dated 04/24/2013,prepared by the manufacturer,signed and sealed by Ronald I.Ogawa,P.E.,bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING:A permanent label with the manufacturer's name or logo,Plant City,Florida,and the following statements:"ASTM C h 186 Type A compliant"and"Miami-Dade County Product Control Approved"is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit panels. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal ofNOA. ADVERTISEMENT:The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided-to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#13-0311.07 and consists of this page 1 and evidence page E-1,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.15-0122.04 MIAMMADECOUNTY Expiration Date:May 1,2017 Approval Date:April 9,2615 WAL1L I$NG7H -- ----_--- -_ f Stud Spacing at 16"O.C. -- --- — SEE DETAILA HardiePanel�.-Cempaneo,& - B'F" � Prevail®Panel Siding materials are .___.--.--r,..___�.._.;,,_. �.,:...�:._._:_,^{itr.__._..• .��• . ! ~� 518")hick/5 ply APA rated nonasbestos fiber-cement products i =t!r t•QGA r plyvveod sheatfiing;n tested in accordance with ASTM i.! i ,1i `,•••' �•rt''•� ` accaxlanoe with Florida C1186 Grade It,Type A and meeting �,+ .`�• ;' the requirements ofthe Florida pst�tsy-r»`�►LSj �, \,� ��� � n9 Code Section Building Code. WALL. it 23223 �O� �Vl PANEL�DIM IONS NEIGH ,�� i7 � I ,�` Water-resist►ve Width length Thickness ��` fl� barrier per Florida 4' 8 910' Sl16" Building Code , t+tia�i ft Aaek�i !! F`•• 'ii �r��: Section 1404.2 QES_f:GN PRES_S_I! E RAT7NG ; '' ij Z X 4r S-P-Ir Installation �Design Pressure i Wood Studs Wood Studs •76 psf _W. `r�!i' ...' B*- HardiePanel, Impact Resistant— Nails at 16"O.C.(typ.) CTJ4N 6�B 0empane1, Planks installed over 5/8"thick/5 ply 318"Minimum Edge Distance Prevail Panel APA rated plywood sheathing , Siding .QF-T"& Sheathing fastener,as described inA — PANEL,PREV¢�L�ANE SIDMG 1NS11q'�IO�i�ETAl1�,S Note 1 All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's installation recommendations,and the applicable sections of the Florida Building Code. �+ • Wood studs where HardiePanel, Cempanel,Prevail Panel Siding will be installer)shall be Panel fastener,as described in designed by an Engineer or Architect per the Florida Building.Code and the requirements of this Note 2 N.OA [Note 1]518"thidc/5 ply APA rated plywood sheathing shall be attached to the studs in Iflo" t accordance with Florida Building Coale Section 2322.3 The siding panels shalf be installed over 6/8'thick 15 ply APA rated plywood sheathing supported 7 r HardiePanel,Cempanel, by a minimum of 2W'S-P-F wood studs spaced a maximum of 16"Q.C. Prevail Panel Siding - [Note zj The siding panel fastener shall be a 2'long,0.223"head diameter,0.092"shank diameter,corrosion resistant siding nail;the fastener;shall be spaced at 6"O.C.at panel edges Card ,� and intermediate studs;the fasteners shall be driven through the 61W thick/5 ply APA rated j plywood sheathing into wood studs located at 18"Q.C. Water-resistive barrier per Fasteners shall have a minimum edge dtstance of 30'and a minimum clearance of 2"from Florida Building Code Section comers. 14042 +\ / MARDIEPANEL,CEMPANEL„PREVAIL PANEL 518"thick/5 ply APA rated INSTALLATION DETAILS WOOL)STUD CONSTRUCTION plywood sheathing fastened in accordance with Florida Building James Hardie Building Products,Inc. Code Section 23223 a 10901 Elm Avenue 2"X 4"S-P_F Wood Studs Fontana,CA 92337 The wall and soffit frames are to be designed Phone:909356-6300 size r-sw NO o- NO �y by the Architect or Engineer of Record in Fax 909-427-0634 A PNL-PLK-SOFF- T7- t compliance 'h the Florida Building Code. Creator.I_Gonzales SCALE 112"_1•-0" Date:4/24/2013 sr,wr 1 OF 12 -- - ---- -- - -------------- ----------- - - -- --- - -- Fastener Spacing per Florida - - - -- ---- Cladding Building Code Section 2322.3� 16.00in. . • I Framing � I .Rtlk'7UCt�vISEO Fastener Spacing per Florida Sheathing �+�•F�. Building Code Sect(on 2322.3 PRODE=2EVLSEID •I `1��� � IDgWiSbdfeda J � I 1 5� I • � � -o� STA�E 0 �� �` I� ProdcaCentsa3 •• F � � ERgNI1NG ■ NOMINAL 2"X 4"S-P-F WOOD STUDS 16"O.C.FASTENED FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE BOTTOM CONNECTION)TH 3 COMMON NAILS(2 PER TOP AND NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) B C ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE _ SHF�4TIillNG � ■ NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD " HARDIEPANEL,CEMPANEL,PREVAIL PANEL SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA INSTALLATION DETAILS WOOD STUD CONSTRUCTION BUILDNG CODE SECTION 2322.3 _C_LAD40!�G ■ THE PANEL IS FASTENED NrH 2"LONG,0.223"HEAD ,lames Hardie Building A Products,Inc. DIAMETER,0.092"SHANK DIAMETER,CORROSION !C ! f0901 E!m Avenue RESISTANT SIDING NAILS, PLACE NAILS 6"O.C.AT Fontana,CA 92337 PANEL EDGES AND INTERMEDIATE STUDS -366-6300 SME FSCM No Dwc rw Rev 27-0634 A PNL-PLK-SOFFr. E.Gonzales - scatF 1 —1'-0" Date:4/24/2013 SHEET 2 OF 12 t WALL LENGTH PRO_D_LiC_T_DESCItlPTiO�j( Stud Spacing at 16"O.C. DETA L A HardtePane!S,CempaneW,&PPevaile _ Panel Siding materials are nonasbestos _..__---- ...._;_._;T�_—.r.1---♦I --_..... ._...... :-- � —518"thick/5 ply APA rated fiber-cement products tested in i --� - -i ~T— `�"-- ��� plywood sheathing fastened accordance wM ASTM C1186 Grade It, ,w. OGA' + , to metal studs as described Type A and meeting the requirements of i I i ��tt i.f in Note 1 the Florida Building Code. me) eida `�e j � PAS Q[itl!!~1_�LQN_S. i f i !" r3i l•v/ �� i Water-resistive Width Length Thickness WALL i �N No. 1 : barrier per Florida 4' 8 g 10' 5116" HEIGHT i is ' : i i : Building Code ' 'i "i i• Section 14042 a -o'•i' STATE Q _ AE;;1�laS �43a1�G I' I � •�O°�� ;` -;�,i ,� �f Installation Design Pressure LQRI 20ga,3-5/8"X 1$18" Metal Studs -104 psi Metal Cstud - -- --r•- — C-- i,� — -���crS'/O r n irrl rr,t HardlePanel, EC Impact Resistant— Panel installed over 5/8"thick/5 ply ,S. �JA,bl�6- Cemparrei, APA rated plywood Nails at S"O.C.(typ.) Prevail Panel sheathing 3/8"Minimum Edge Distance Siding AIkA ■ ' All installation shall be done in conformance with this Notice of Acceptance,the manufacturer's Installation recommendations,and the applicable sections of the Florida Building Code. Metal studs where HardlePanel,Cempanel,Prevail Panel Siding will be installed shall be Sheathing fastener,as designed by an Engineer or Architect per the Florida Building Code and the requirements of this \ described in Note 1. N.O.A. - �e Fhxis (Note 1]5/8"thick/5 ply APA rated plywood sheathing shall be attached to metal studs at 6"00 cede Parfet fastener,as described in at panel edges and all intermediate supports using a No.8-18,0.315"head diameter X 1-114"long Note 2 bugle head screw ■ The siding panels shall be installed over 5/8"Ne k 15 ply APA rated plywood sheathing supported by a minimum 20ga,Nominal 3-51W X 1-5/8"Metal C•studs spaced a matamum of 16" Camel ! O,C. HardiePanel®Siding ■ jNote 2]The siding panel fastener shall be a minimum No.8-18,0.315"head diameter X 1-5/8" long ribbed bugle head screw("or screwshall have at least 3 full threads penetrating.metal + , framing);the fasteners shall be spaced at 5'O.C.at panel edges and intermediate studs;the \ J fasteners shall be driven through the 5/8"thick/5 ply APA rated plywood sheathing Into metal Water-resistive barrier per studs located at 16"O.C. �+ Florida Building Code Section Fasteners shall have a minimum edge distance of 3/8"and a minimum clearance of 2"from 1404.2 comers. HARDIEPANEL,CEMPANEL,PREVAIL PANEL 518"thick 5 ply APA rated INSTALLATION DETAILS METAL STUD CONSTRUCTION i / 1 plywood sheathing fastened James Hardie Building Products,Inc. i to metal studs as described 10901 Elm Avenue -LLin Note 1. e Fontana CA 92337 209a,3-8/8"X 1-5/8'.Metal C-stud The wall and soffit frames are to be designed Phone:909-356-6300 ssze FSc�,NO Owc No REV • by the Architect or Engineer of Record in Fax 909-�327-0634 A PNL-PLK-SOFF 1 compliance with the Florida Building Code. Creator.E.Gonzales SCALE' t 2^=1'-0- Date:4/2412013 SHEET 3 OF 12 6.00in. �- ------- -- -- - -- - --- - -- --- - ----— -16.00in. Gadding - - - --- 1 6.0dni •� f ' J .I I f �'I •! •I Framing • .' l.i I•i . �■I 6.00in.! I I Sheathing II II 6.00in. i I I • PRdbllCSbiFy prREVIS® ! ; I I I �� f .QGQ pj�, =beFiosida *eFloeira i ���511`� "5�..• ,quep0odeo No f'-G�31!G� Ao�.ra�e Nu���� I � I 1 � gr �' I • 1"waaee e�eaa * * I I ' : -o STATE OF F40R1�P:I I = S/ONAI� , �+iiiirrrl/�l ■ NOMINAL 20 GAUGE 3-518"X 1-$/8"STEEL STUDS IV,O.C. FASTENED WITH 5/8"WAFER HEAD SCREWS(2 PER TOP j AND BOTTOM CONNECTION) FOR METAL AND WOOD STUDS,PROVISIONS FOR DIAPHRAGM ACTION AND GRAVCI'Y LOAD ARE ■ THE WALL AND FRAMES ARE 70 BE DESIGNED NOT PART OF THIS APPROVAL(MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS BY THE ARCHITEECTCT O OR ENGINEER OF RECORD 1N ) COMPLIANCE WITH THE FLORIDA BUILDING CODE SiiEA'fHJIVG_ = NOMINAL 5/8"THICK/5 PLY APA RATED PLYWOOD SHEATHING TO METAL STUDS AT V'OC AT PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL,CEMPANEL,PREVAIL PANEL N0.8-18,0.315"HEAD DIAMETER 1-1/4"LONG BUGLE HEAD SCREW INSTALLATION DETAILS METAL STUD CONSTRUCTION Ci_AODING r THE PANEL IS FASTENED WITH NO,8-18,0.315"HEAD James Hardie Building Products,Inc. DIAMETER X 1-5/8'LONG CORROSION RESISTANT 10901 Ei n Avenue RIBBED BUGLE HEAD SCREWS(SCREW SHALL KAVE A, Fontana,CA 92337 LEAST 3 FULL THREADS PENEi RATING THE METAL Phone:909-35e- 300 Sty rscu No DM NO REv FRAMING),PLACE SCREWS 6"O.C.AT PANEL EDGES p�g09-427-0634 A PNL-PLK-SOFF 1 AND INTERMEDIATE STUDS Creator.E Gonzales SME V=1'-0" Date:4/24/2013 SHEET 4 OF 12 m N1At,L LENGTH SEE �RODt}GT bir LC P_71_QN Stud Spaang at 16"O.C. DETAJL A HardiePlankA Cemplank®,& B 4---i ---- Prevail®Plank Lap Sitting materials _..�.-. . .....,�...� .--.-----,...__ ,� �` 51 thick!5 Ply APA are nonasbestas fiber-cement ..__._ ;' l;— ;r i,It rated plyvvaod products tested in accordance with sheathin in ASTM C1186 Grade If.,Type A and' t� ��irrtiii,,y� accordance with meeting the requirements of the as wii�1' ]rTosiQa ;i 601 _ ( Florida BuUding Code Florida Building Code. ( i t i -LIP SO ►ti .. Se0on 2322.3 WALLHEIGHT i ! (i ., ,i �` Watrrr4"ttnr vridth Length Thickness barrier per Florida 12' 5/16" f Building Code Section 1aQa2 pESGPRES_5_UA rM ER 2°X 4 S-P F installation Design Pressure Wood Studs Wood Studs -92 psi '� Lap Siding Impact Resistant— B ' 3!4"Minimum Edge Distances at 16"O.C�(typ.) �'�SlO N, , >5 0 Piania installed over 6/8"thick 15 ply g-g 1A14'taU x 5116" APA rated plywood sheathing '. thick starter strip -Sheathing fastener,as Hg � �,pNi(,,C�'iNPLA�1y_C,rp�g/ ttiLq�S�DJNGJSJ,LU-i-A' oN�. CAJ[4S described in Note 1 • All installation shag be done in conformance with this Notice of Acceptance,the manufacturer's . instalation recommendations,and the applicable sections of the Florida,Bulding Code. �01 `� Wood studs where Hardiepiank,Cemplank,Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA (Note 115/8"thick 15 ply APA rated plywood sheathing shall be attached to the studs in accordance \ Siding fastener,as with Florida Building Code Section 2322.& p� described in Note 2 . Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4"wide 0 + ', laps at the top of the plank such that the exposure area of each plank Is:5 8-1/4"vertically. Ns S , HardiePlank, (?dote 21 The siding fastener shall be a 2AW long,0.22V'head diameter,0.092"shank diameter, 1-19 Cemplank,Prevail corrosion-resistant siding nail;The siding is fastened S 8-1/4"O.C.vertically and 16"O.C.horizontally; i fasteners are driven into wood studs through 6/8"thick/5 ply APA rated plywood sheathing,fasteners �!' r, Lap Siding are placed in the overlapping area approximately 3/4'from the bottom edge of the overlapping plank s•Ziw , Vertical joints shall be placed over studs. + / Water-resistive barrier The planks shall be installed over 518"thick/6 ply APA rated plywood sheathing supported by a per Florida Building minimum of 2")(4"S-P-F wood studs spaced a maximum of 16"O.C. Code Section 1404.2 Fasteners shall have a minimum edge distance of318". 5/8"thick/5 ply APA rated HARDIEPLANK,CEMPLANK,PREVAIL LAP SIDING ---'�' plywood sheathing fastened iNSTALLATiON MAILS WOOD STUD CONSTRUCTION ----.in accordancewiYn Florida • JamesSection Hardie BurTdi e ng Products,th 2322.3 � 0 _ •1Q901 Elm Avenue Fontana,CA 92337 2"X 4"S-P-F Wood Studs Phone;909.386-830a sin PscM No OM No REV _ The wag and soffit frames are to be designed Fax 909-427-0534 A PNL-PLKvOF1= 1 'by the A.chitect or Engineer of Record in cornpriance Florida Building Code. Creator.S.Gonzales SCALE 1/2"-1'-0" Date:4/24/2t113 ;ft7 5 OF 12