GENERAL NOTES:
9'-4"
PRE-ENGINEERED TRUSSES
7/16" APA RATED SHEATHING
W/ 8d RINGED NAILS @ 4" O.C. EDGE
AND 6" O.C. FIELD
25-YR. ASPHALT SHINGLES
ON (2) LAYERS OF 30# FELT
SEE CONNECTOR
SCHEDULE TYP.
DOUBLE TOP PLATE
DOOR AND WINDOW HEADERS
TO BE 2.0E 5 4'x11 4" PARALLAM;
(1) STUD FOR OPENINGS <6'
(2) STUDS FOR OPENINGS 6' TO 10'
(3) STUDS FOR OPENINGS 10' TO 16'
SEE NOTES FOR OPENINGS >16'
LSTA24 @ EACH JAMB STUD
TO HEADER TYP.
SIMPSON HTT5 CONNECTOR
W/ 5/8" ANCHOR BOLT
EA. SIDE OF JAMBS
AND WHERE SHOWN
6" 3,000 PSI CONCRETE
ON 6 MIL VAPOR BARRIER
W/ TERMITICIDE TREATMENT
6X6-10/10 WWM
TESTED AND COMPACTED SOIL
BEARING CAPACITY 2,500 PSF
2 - NO. 5 BARS CONT.
4 - NO. 5 BARS SHORT WAY IN
OPENINGS GREATER THAN 8'- 0"
1. WEATHERING AREA IS NEGLIGIBLE
2. TERMITE AREA IS VERY HEAVY
3. THE FLOOR OF THE GARAGE OR CARPORT SHALL BE SLOPED W/ NATURAL CONCRETE OR PAINTED WITH A NONCOMBUSTIBLE MATERIAL.
4. ALL EXIT DOORS SHALL HAVE A LIGHT W/ A FLAT 48" X 48" LANDING.
5. ALL WOOD -FRAMING MEMBERS RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH FASTENERS OF HOT -DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. PROTECTION FROM DECAY SHALL BE REQUIRED PER FBC R-319.1,
6. ACCESSIBILITY DOORS SHALL HAVE A 29" MIN. CLEARANCE,
7. THE SITE ADDRESS OR NUMBERS SHALL BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
S. ALL STRUCTURE FOOTERS SHALL BE A MINIMUM OF 12" BELOW GRADE.
9. FOUNDATION STEEL (#5 BARS) SHALL HAVE A MINIMUM OF 3" OF COVER.
10. A CONTINUOUS PATH FROM FOUNDATION TO ROOF SHALL BE PROVIDED PER DETAILS AND CONNECTIONS SPECIFIED.
11. ROOF AND WALL COMPONENT AND CLADDING LOADS ARE SHOWN IN THE DESIGN CRITERIA.
12. SHUTTERS OR IMPACT GLASS IS REQUIRED FOR PROTECTION OF OPENINGS FOR THIS RESIDENCE PER SECTION R301.2.1.2 OF THE FLORIDA RESIDENTIAL BUILDING CODE.
13. INTERIOR AND BEARING AND NON -BEARING FRAMED WALLS SHALL USE STUD GRADE LUMBER SPACED AT 16" O.C..
14. FRAMED BEARING WALLS SHALL BE BRACED WITH 2X4S ® A MAXIMUM OF 8' O.C.
15. FRAMED WALLS HIGHER THAN 8'0" SHALL HAVE A ROW OF FIREBLOCKING AT MID -HEIGHT OF WALLS.
16. ROOF SHEATHING SHALL BE I" COX AND HAVE A SPAN RATING OF 16/24 AND NAILED WITH 8D RING OR SCREW TYPE NAILS (2 11h" X .131") AT 4" O.C. ON THE SEAMS AND 6" O.C. IN THE FIELD.
17. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C36, C79, C 475, C514, C630, C931, C960, C10D2, C1047, C1177, C1178, C1278, C1395 OR C1396 AND SHALL BE IN INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SECTION
702.3 OF THE CURRENT FLORIDA RESIDENTIAL BUILDING CODE. ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C557.
18. ACCESS OPENING SHALL BE A MINUMUN OF 16" X 24" AND SHALL NOT BE UNDER AN EXTERIOR DOOR OR LOCATED BEHIND AN EXTERIOR FIXTURE.
19. ALL NAILS SHALL BE HOT DIPPED GALVANIZED OR BETTER.
20. ALL SIMPSON FASTENERS SHALL BE Z-MAX WITH HOT -DIPPED GALVANIZED COMMON NAILS OR BETTER.
21. ALL BEARING WALLS SHALL HAVE A SIMPSON SPH4/6 PLACED TOP AND BOTTOM OF FRAMED WALL AT 16" O.C.. HEADERS OVER 4' SHALL BE STRAPPED TO JACKS W/ SIMPSON MSTA24 AT ENDS W/ 8-10d NAILS PER SIDE. HEADERS UNDER 4' SHALL BE
STRAPPED W/ SIMPSON LSTA18 W/ 7-10d NAILS PER END. EACH JACK SHALL HAVE A H2.5A ® THE BOTTOM PLATE.
22. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ROOF PITCH.
23. NO SCREWS SHALL BE USED IN THE PLYWOOD SHEATHING OR WOOD MEMBERS OR ANY SIMPSON PRODUCTS UNLESS SPECIFIED IN THESE PLANS OR FROM THE MANUFACTURER,
24. ROOF RAIN WATER SHALL BE DIVERTED FROM SEPTIC FIELD.
25. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL.
26. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12" AWAY FROM BUILDING WALLS.
27, IRRIGATION/SPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 12" OF THE BUILDING WALLS.
28. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" BELOW FINAL WALL COVERING.
29. INITIAL TERMITE TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE..
30. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED.
31, BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC. SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANC OF
SOIL AFTER THE INITIAL TREATMENT.
32. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED.
33, CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT.
34. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12" OF THE STRUCTURE WALLS.
35. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED.
36, ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT.
37. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING
HAS REEVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
38. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING, OR OTHER CELLULOSE CONTAINING MATERIAL.
39. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15' OF ANY BUILDING OR PROPOSED BUILDING.
17
20"
FRAME EXTERIOR WALL SECTION
12 2X4 NAILER FOR SOFFIT
3 ATTACH W/ 3-16d NAILS
@ EA. STUD
1X6 FASCIA BOARD
ON 2X4 SUBFASCIA
VENTED PLYWOOD SOFFIT
W/ 12" OVERHANG
2X4 NAILER @ 24" O.C.
W/4-16d EA. TRUSS TAIL
AND 2-16d TOENAILS @
WALL NAILER TYP.
HARDIE SIDING APPLIED PER
MANUF. REQUIRMENTS OVER
30# FELT TYP.
2X6 WALLS W/ STUDS @ 16" O.C.
W/ SP6 TOP AND BOTTOM AND
Y2" CDX W/ 8d RINGSHANK NAILS
@ 6" O.C. ON EDGES AND
6" O.C. IN FIELD TYP.
5/8" ANCHOR BOLTS
@ 24" O.C.
P.T. BOTTOM PLATE
AND MONOLITH/C SLAB FOOTING
SCALE: N.T.S.
TABLE R302.6
DWELLING/GARAGE SEPARATION
SEPARATION MATERIAL
From the residence and attics Not less than
1/2-inch gypsum board or equivalent applied
to the garage side
From all habitable rooms above the garage
Not less than 5/8-inch Type X gypsum board
or equivalent
Structure(s) supporting floor/ceiling
assemblies used for separation required by
this section Not less than 1/2-inch gypsum
board or equivalent
Garages located less than 3 feet from a
dwelling unit on the same lot Not less than
1/2-inch gypsum board or equivalent applied
to the interior side of exterior walls that are
within this area
DEPT. COMMENTS 12/11/17
GRADE
1/4" X 3" WOOD SCREW
NO MORE THAN 6"
FROM END @ 12" O.C.
2" X 4" BUCK
BUCKA TTACHMENT
SCALE: N.T.S.
30"
FOOTING CORNER REINFORCING BARS
SCALE: N.T.S.
DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE
1. BUILDING CATEGORY II
2. FLORIDA BUILDING CODE RESIDENTIAL 2014
3. BUILDING DESIGN IS ENCLOSED
4. MEAN ROOF HEIGHT IS < 15'
5. ROOF PITCH 3/12
6. INTERNAL PRESSURE COEFFICIENT +/- 0.18
7. WIDTH OF END ZONE A = 4.8'
8. WIND SPEED: (Vult) 170 MPH 3-SECOND GUST
(Vasd) 132 MPH 3-SECOND GUST
9. WIND EXPOSURE CLASSIFICATION: D
10. ADJUSTMENT FACTOR FOR EXPOSURE & HEIGHT = 1.21
11. COMPONENT & CLADDING WIND PRESSURE ON ROOF:
ZONE 1 = NA
ZONE 2 = NA
ZONE 3 = NA
12. COMPONENT & CLADDING WIND PRESSURE ON WALL:
ZONE 4 = SEE TABLE
ZONE 5 = SEE TABLE
13. COMPONENT & CLADDING WIND PRESSURE ON SOFFITS (FULLY CLOSED):
ZONE 2 = +/- 59.8 PSF
ZONE 3 = +/- 59.8 PSF
14, LOADS:
FLOOR 40 PSF
ROOF/DEAD 20 PSF
ROOF/LIVE 20 PSF
WALL 18 PSF
15. SHEAR WALLS WERE CONSIDERED
16. A CONTINUOUS LOAD PATH WAS PROVIDED
17. COMPONENT & CLADDING DETAILED
18. MINIMUM SOIL BEARING PRESSURE IS 2000 PSF
FIBERMESH OR
WELDED WIRE MESH
SEE FOUN. NOTES
#5 CONTINUOUS
FOOTING REBAR
(2) #5 BARS
-ac-�
(2)#5 BARS CONTIN.
_
FIBERMESH
-+
20
/j
OR W.W.M.
_ 20 i
TYP. EXTERIOR CONT.
F1 MONOLITHIC FOOTING
TYP. EXTERIOR CONT.
F2
CURB MONO -FOOTING
145 BARS CONT.
14" F;-FIBERMESH OR
FIBERMESH
WELDED WIRE MESH
OR W.W.M. I
Q (2)#5 BARS CONTIN.
(V
,8"
20
X
OSTEPPED INTERIOR
F3 MONOLITHIC
"I
O TYP. GARAGE RECESS
F4
FOOTING
MONOLITHIC FOOTING
4"
SP,
-7io-OW")
GOUTY 9C�'�NG pp! -Slog
FIBERMESH
.['f'tQ,
p,r;(1FltEDFORCOW11C
OR W1-#MCONT. h}
Il:01 GD BY
g
3" MIN. COVER /-" r
C ➢ PERNUT JOB
tDINSPECTION WILLBEMADE.
TYP. THICKENED EDGE
F5
MONOLITHIC FOOTING
FOUNDATION NOTES
+. SOILS SIALL BE TREATED.
2 SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM - 1557 (MODIFIED PROCTOR).
FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2500 PSF.
FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS.
CONCRE-E NOTES
ALL
UI
t. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR STRUCTURAL
CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. STRUCTURAL
CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN
28 DAYFCF 3000 PSF. UNLESS NOTED OTHERWISE. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4INCHES PLUS OR
MINUS CJE INCH.
2 PROVIDRA MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES s GARAGES. HOLES IN VAPOR BARRIER ARE
NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS.
ALL REIFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEEL/WELDED WIRE MESH TO CONFORM TO ASTM A-185.
PROVIDICHAIRS & BOLSTERS. BOLSTERS TO HAVE PLASTIC COATED LEGS & FEET (IF EXPOSED TO EXTERIOR ELEMENTS)
ENSURFIAESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE.
WELDEWRE FABRIC SHALL BF IN ACCORDANCE WITH ASTM A185 AND SHALL BE ADEQUATELY SUPPORTED a 3'-0" O.C.
EACH V4¢!
THE MIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: CAST AGAINST EARTH. 3", EXPOSED TO EXTERIOR ELEMENTS.
1", FORIFD SURFACES: 1"
CONSTRICTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND
SPECIFI TIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY
THE ENIEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED.
- CHECK CL DRAWINGS AND APPLICABLE MANUFACTURE'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH
AS PIPEILEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE.
REINFOrEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 30 INCH LAP. PROVIDE
CORNE33ARS
CONCRFE SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IS NOT PERMITTED FOR SLABS.
ALL COrRETE THAT IS ALTERED (WATER, ADDITIVES, ETC.) SHALL BE TESTED TO ENSURE STRENGTH REQUIREMENTS ARE
MET.
TERMINTE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS.
Scott R. Sanders, P.E.
FL P.E. No. 64781
}
m
LU
r
H-
C]
N
F
z
z
w
0
v�
Lu
0
w
H
Ld
w
0
U
0
J
m
W
> 00
O
M
W W U.
W
Z U
� a a
N
O LL
W Z
0_
4 F-
Q �
� a
FACTURES LABLES SHOWING
RS AND SHGC COMPLIANCE
FSC ENERGY CODE MUST
ALL DOORS AND WINDOWS
ISPECTIONS
CO FAST�NEr"iS Q nr iCH'"ENT S
Tf!E RE�PONs1911.�TY 0= Ti�C
CONTRACTOR OFRkORO
IITETIIEATI ENTf ew
PLANAR ANn ALL PnoT+g9ED WOp
1,16JECT M ANY CORFERTION8
HIED BY FIELD INaD'oTr.S THAT
E NNCIECAAV Ii` ,,P03 TO
W WITH A66 0*619hhk 00096,
DATE: 7/14/17
SCALE: NTS
JOB NO.: NA
DRAWN BY: SRS
CHECKED BY SRS
SHEET NO.
1 of
File Copy
12" OVERHANG TYP.
12" Ob
ROOF SHEATHING PER SPECS.
PRE-ENGINEERED
TRUSSES @ 24" O.C.
j;
VALLEY SET FRAMING
PER TRUSS MANUF.
1
OVERFRAMING DETAIL
SCALE: N.T.S.
WEST EL/A TION
SCALE:1/4"=l'
NORTH ELEVA TION
SCALE: 1/4"=l'
FASTEN EA. VALLEY TRUSSES
THROUGH SHEATI NG TO TRUSSES
BENATH W/ LSTA18 OR MTS16 TYP.
2x6 W/2-fX4" LAG SCREWS
SPACED 24" O.C. TO TOP CHORD
OF EXISTING TRUSSES
PROVIDE ONE AT VALLEYS AND
EVERY 8'-0" MAX.
EX. TRUSS TAILS
TO BE REMOVED
EXISTING WALL TO REMAIN
F.
12 12 w
5
5 o N
12
w I�
Z
ZW
o
EX. STUCCO HOUSE
O
in
\ U
TO REMAIN TYP. \ w
12" OVERHANG TYP. W
\\\ \\\ U
m
&BLDG. DEPT. COMMENTS 12/11/17
EX. FRAMED OPENING
TO REMAIN TYP.
WINDOWINFILL
Z�BLDG. DEPT, COMMENTS 121l1/17
EX. 73" WIDE x 38" HIGH
WINDOW TO BE REMOVED
ADD 2X's AS SHOWN WHEN WINDOWS
ARE REMOVED; ATTACH TO EX. FRAMING
W/ 16d NAILS @ 12" O.C. MAX. NO MORE
THAN 6" FROM ENDS; SPACE INTERMEDIATE
STUDS AT 16" O.C. MAX TYP.
Z)UALt: IN I J
EX. 73" WIDE x 38" HIGH_
- WINDOW TO BE REMOVED
EX. GAR4GE WALL
SCALE:1/4"=l'
I I I
EAST EL/A TION
SCALE:1/4"=l'
PRODUCT
MODEL NO.
MANUFACTUER
EVALUATION
AGENCY
PRODUCT
APPROVAL NO.
EXPIRATION
DATE
WINDOWS
SILVERLINE
ANDERSON
FL#14911 R7
8/3/2021
EXTERIOR DOORS
PLASTPRO
FL#15213.1
12/31/2018
GARAGE DOORS
DAB
FL#12698.7RO
7/21/2020
OFF RIDGE VENT / RIDGE VENT
SOFFIT
JAMES HARDIE
FL#13265
1/l/2018
SKYLIGHTS
SHUTTERS
ROOF COVERING
OWENS CORNING
FL#10674 R12
8/20/2017
STRUCTURAL CLADDING
JAMES HARDIE
FL#13223 R1
1/l/2018
EX. 16' WIDE x THIGH OVERHEAD
GARAGE DOOR TO BE REMOVED
CONNECTOR LEGEND
86 UPLIFT
2 CONNECTOR TYPE
NUMBER OF CONNECTORS
CONNECTOR SCHEDULE
07-14-17
I.D.
MFG'R.
CONNECTOR
LATERAL
UPLIFT
FASTENERS
FLORIDA
Fl/F2
STRUCTURE
TRUSS
APPROVAL
#
A
SIMPSON
HTS20
1,007 1,007
1,450
12
10d xl-1
2"
12
10d
A-1
2"
10456
13872
Al
SIMPSON
HTS20
1,007 1,007
1,450
12
10d x1-1
2"
12
10d
xi-1
2"
10456
13872
A2
SIMPSON
HTS20
1,007 1,007
1,450
12
10d xl-1
2"
12
10d
xl-1
2"
10456
13872
A3
SIMPSON
HTS20
1,007 1,007
1,450
12
10d xl-1
2"
12
10d
xl-1
2"
10456
13872
A4
SIMPSON
HTS20
1,007/1,007
1.450
12
10d xl-1
2"
12
10d
xl-1
2"
10456
13879
A5
SIMPSON
HTS20
1,007/1,007
1,450
12)
10d x1-1
2"
(12)
10d
A-1/2"
10456 /
13872
A6
HTS20
1,007 1,007
1,450
12
10d xt-1
2°
12
10d
x1-1
2'
10456
13872
GRA
SIMPSON
(2)HTS20
2.253 2 253
2,900
24
10d xl-1
2"
24
10d
xl-1
2"
10456
13872
Ji
SIMPSON
I LTS12
250
720
6
10d xl—1
2"
10456
13872
J3
SIMPSON
LTS12
161
x —
10456
13872
J5
SIMPSON
LTS12
197
720
6
10d xl-1
2"
10456
13872
J7
SIMPSON I
LTS12
237
720
6
10d xl-1
2"
10456
13872
KJ7
SIMPSON I
LTS12
437
720
6
10d xl-1
2"
10456
13872
V20
SEE DETAIL
FOR STRAPPING
VA
SEE DETAIL
FOR STRAPPING
VB
SEE DETAIL
FOR STRAPPING
VC
SEE DETAIL
FOR STRAPPING
I
&C Vasd Wa[i .,Vind Pressures
170 C Msk C
<15 Et.
Zone 4 InterioJIG)
Zone 5 Exterior
!�) 10 SF =+37.9 -4)
10 SF=+37J%-50.8
B) 20 SF=+36.2/-3)
20 SIF =-36.2/-47.3
C) 50 SF _ +33.9 -3
�0 SF = +33.9/-42.8
D) 100 SF=+32.2/-3)
100 Sl = 132.2i-39.4
Garage Door aii
from corners
J) 9'x7'=+33.4 -37.8
) 16'x7'=+31.9/-35.6
Scott R. Sanders, P.E.
FL P.E. No. 64781
W
00
N>
I.L.
�
0
M
I—'
W
J
W
LL
^W
+
N
w
LLJ
Z
U
Y
a
a
N
CD
LC�
U.
0 9
DATE: 7/14/17
SCALE: NTS
JOB NO.: NA
DRAWN BY: SRS
CHECKED BY SRS
SHEET NO
of 4
File, Copy
DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE
40' 0"
11101,
GENERAL NOTES:
0' 0"
110 20' 0"
30' 0"
9'-4"
DOUBLE TOP PLATE
DOOR AND WINDOW HEADERS
TO BE 2.0E 5 4" X11 4' PARALLAM;
(1) STUD FOR OPENINGS <6'
(2) STUDS FOR OPENINGS 6' TO 10'
(3) STUDS FOR OPENINGS 10' TO 16'
SEE NOTES FOR OPENINGS >16'
LSTA24 @ EACH JAMB STUD
TO HEADER TYP.
SIMPSON HTT5 CONNECTOR
W/ 5/8" ANCHOR BOLT
EA. SIDE OF JAMBS
AND WHERE SHOWN
6" 3,000 PSI CONCRETE
ON 6 MIL VAPOR BARRIER
W/ TERMITICIDE TREATMENT
6X6-10/10 WWM
TESTED AND COMPACTED SOIL
BEARING CAPACITY 2,500 PSF
2 - NO. 5 BARS CONT.
4 - NO. 5 BARS SHORT WAY IN
OPENINGS GREATER THAN 8'- 0"
1. WEATHERING AREA IS NEGLIGIBLE
2. TERMITE AREA IS VERY HEAVY
3. THE FLOOR OF THE GARAGE OR CARPORT SHALL BE SLOPED W/ NATURAL CONCRETE OR PAINTED WITH A NONCOMBUSTIBLE MATERIAL.
4. ALL EXIT DOORS SHALL HAVE A LIGHT W/ A FLAT 48" X 48" LANDING.
5. ALL WOOD -FRAMING MEMBERS RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH FASTENERS OF HOT -DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. PROTECTION FROM DECAY SHALL BE REQUIRED PER FBC R-319.1.
6. ACCESSIBILITY DOORS SHALL HAVE A 29" MIN. CLEARANCE.
7. THE SITE ADDRESS OR NUMBERS SHALL BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY,
8. ALL STRUCTURE FOOTERS SHALL BE A MINIMUM OF 12" BELOW GRADE.
9. FOUNDATION STEEL (#5 BARS) SHALL HAVE A MINIMUM OF 3" OF COVER.
10. A CONTINUOUS PATH FROM FOUNDATION TO ROOF SHALL BE PROVIDED PER DETAILS AND CONNECTIONS SPECIFIED.
11. ROOF AND WALL COMPONENT AND CLADDING LOADS ARE SHOWN IN THE DESIGN CRITERIA.
12. SHUTTERS OR IMPACT GLASS IS REQUIRED FOR PROTECTION OF OPENINGS FOR THIS RESIDENCE PER SECTION R301.2.1,2 OF THE FLORIDA RESIDENTIAL BUILDING CODE.
13. INTERIOR AND BEARING AND NON -BEARING FRAMED WALLS SHALL USE STUD GRADE LUMBER SPACED AT 16" O.C..
14. FRAMED BEARING WALLS SHALL BE BRACED WITH 2X4S @ A MAXIMUM OF 8' O.C.
15. FRAMED WALLS HIGHER THAN 8'0" SHALL HAVE A ROW OF FIREBLOCKING AT MID -HEIGHT OF WALLS.
16. ROOF SHEATHING SHALL BE J" COX AND HAVE A SPAN RATING OF 16/24 AND NAILED WITH 8D RING OR SCREW TYPE NAILS (2 11h" X .131") AT 4" O.C. ON THE SEAMS AND 6" O.C. IN THE FIELD.
17. ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C36, C79, C 475, C514, C630, C931, C960, C1002, C1047, C1177, C1178, C1278, C1395 OR C1396 AND SHALL BE IN INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SECTION
702.3 OF THE CURRENT FLORIDA RESIDENTIAL BUILDING CODE. ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C557.
18. ACCESS OPENING SHALL BE A MINUMUN OF 16" X 24" AND SHALL NOT BE UNDER AN EXTERIOR DOOR OR LOCATED BEHIND AN EXTERIOR FIXTURE.
19. ALL NAILS SHALL BE HOT DIPPED GALVANIZED OR BETTER.
20. ALL SIMPSON FASTENERS SHALL BE Z-MAX WITH HOT -DIPPED GALVANIZED COMMON NAILS OR BETTER.
21. ALL BEARING WALLS SHALL HAVE A SIMPSON SPH4/6 PLACED TOP AND BOTTOM OF FRAMED WALL AT 16" O.C.. HEADERS OVER 4' SHALL BE STRAPPED TO JACKS W/ SIMPSON MSTA24 AT ENDS W/ 8-10d NAILS PER SIDE. HEADERS UNDER 4' SHALL BE
STRAPPED W/ SIMPSON LSTA18 W/ 7-10d NAILS PER END. EACH JACK SHALL HAVE A H2.5A ® THE BOTTOM PLATE.
22. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ROOF PITCH.
23. NO SCREWS SHALL BE USED IN THE PLYWOOD SHEATHING OR WOOD MEMBERS OR ANY SIMPSON PRODUCTS UNLESS SPECIFIED IN THESE PLANS OR FROM THE MANUFACTURER.
24. ROOF RAIN WATER SHALL BE DIVERTED FROM SEPTIC FIELD.
25. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRIC PANEL.
26. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12" AWAY FROM BUILDING WALLS.
27. IRRIGATION/SPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 12" OF THE BUILDING WALLS.
28. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" BELOW FINAL WALL COVERING.
29. INITIAL TERMITE TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE..
30. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED.
31. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC. SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANC OF
SOIL AFTER THE INITIAL TREATMENT.
32, MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED.
33. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT.
34. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12" OF THE STRUCTURE WALLS.
35. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED.
36. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT.
37. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING
HAS REEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
38. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING, OR OTHER CELLULOSE CONTAINING MATERIAL.
39. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 16 OF ANY BUILDING OR PROPOSED BUILDING.
PRE-ENGINEERED TRUSSES
7/16" APA RATED SHEATHING
W/ 8d RINGED NAILS @ 4" O.C. EDGE
AND 6" O.C. FIELD
25-YR. ASPHALT SHINGLES
ON (2) LAYERS OF 30# FELT
SEE CONNECTOR
SCHEDULE TYP.
12 2X4 NAILER FOR SOFFIT
3 ATTACH W/ 3-16d NAILS
@ EA. STUD
1X6 FASCIA BOARD
ON 2X4 SUBFASCIA
VENTED PLYWOOD SOFFIT
W/ 12" OVERHANG
2X4 NAILER @ 24" O.C.
W/ 4-16d EA. TRUSS TAIL
AND 2-16d TOENAILS @
WALL NAILER TYP.
HARDIE SIDING APPLIED PER
MANUF. REQUIRMENTS OVER
30# FELT TYP.
2X6 WALLS W/ STUDS @ 16" O.C.
W/ SP6 TOP AND BOTTOM AND
%2" CDX W/ 8d RINGSHANK NAILS
@ 6" O.C. ON EDGES AND
6" O.C. IN FIELD TYP.
5/8" ANCHOR BOLTS
@ 24" O.C.
P.T. BOTTOM PLATE
FRAME EXTERIOR WALL SECT/ON
AND MONOL/TH/C SLAB FOOTING
SCALE: N.T.S.
1/4" X 3" WOOD SCREW
NO MORE THAN 6"
FROM END @ 12" O.C.
2" X 4" BUCK
BUCKA TTACHMENT
SCALE: N.T.S.
30"
GRADE
FOOTING CORNER REINFORCINGBARS
SCALE: N.T.S.
1. BUILDING CATEGORY II
2. FLORIDA BUILDING CODE RESIDENTIAL 2014
3. BUILDING DESIGN IS ENCLOSED
4. MEAN ROOF HEIGHT IS < 15'
5. ROOF PITCH 3/12
6. INTERNAL PRESSURE COEFFICIENT +/- 0.18
7. WIDTH OF END ZONE A = 4.8'
8. WIND SPEED: (Vult) 170 MPH 3-SECOND GUST
(Vasd) 132 MPH 3-SECOND GUST
9. WIND EXPOSURE CLASSIFICATION: D
10. ADJUSTMENT FACTOR FOR EXPOSURE & HEIGHT = 1.21
11. COMPONENT & CLADDING WIND PRESSURE ON ROOF:
ZONE 1 = NA
ZONE 2 = NA
ZONE 3 = NA
12. COMPONENT & CLADDING WIND PRESSURE ON WALL:
ZONE 4 = SEE TABLE
ZONE 5 = SEE TABLE
13. COMPONENT & CLADDING WIND PRESSURE ON SOFFITS (FULLY CLOSED):
ZONE 2 = +/- 59.8 PSF
ZONE 3 = +/- 59.8 PSF
14. LOADS:
FLOOR 40 PSF
ROOF/DEAD 20 PSF
ROOF/LIVE 20 PSF
WALL 18 PSF
15. SHEAR WALLS WERE CONSIDERED
16. A CONTINUOUS LOAD PATH WAS PROVIDED
17. COMPONENT & CLADDING DETAILED
18. MINIMUM SOIL BEARING PRESSURE IS 2000 PSF
FIBERMESH OR
WELDED WIRE MESH
SEE FOUN. NOTES
#5 CONTINUOUS
FOOTING REBAR
(2) #5 BARS
(2)#5 BARS CONTI N.
FIBERMESH
OR W.W.M.
_ 20"�20
-I
TYP. EXTERIOR CONT.
F1 MONOLITHIC
TYP. EXTERIOR CONT.
F2
FOOTING
CURB MONO -FOOTING
145 BARS CONT.
14" FIBERMESH OR
FIBERMESH
WELDED WIRE MESH
OR W.W.M. I
(2)#5 BARS CONTIN.
t
(r t/7
_.-._
20"
OSTEPPED INTERIOR
F3 MONOLITHIC FOOTING
O TYP. GARAGE RECESS
F4
MONOLITHIC FOOTING
4"
.o
FIBERMESH t
OR W.W.M. --
145CONT. I Ell
3" MIN. COVER /---
F5 TYP. THICKENED EDGE
MONOLITHIC FOOTING
FOUNDATION NOTES
1. SOILS SHALL BE TREATED.
2, SOILTO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM - 1557 (MODIFIED PROCTOR).
3. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2500 PSF.
4. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS.
CONCRETE NOTES
1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR STRUCTURAL
CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. STRUCTURAL
CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN
28 DAYS OF 3000 PSF. UNLESS NOTED OTHERWISE. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR
MINUS ONE INCH.
2. PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & GARAGES. HOLES IN VAPOR BARRIER ARE
NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS.
3_ ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEELANELDED WIRE MESH TO CONFORM TO ASTM A-185.
PROVIDE CHAIRS & BOLSTERS. BOLSTERS TO HAVE PLASTIC COATED LEGS & FEET (IF EXPOSED TO EXTERIOR ELEMENTS)
ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE.
4. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185 AND SHALL BE ADEQUATELY SUPPORTED @ 3-0" O.C.
EACH WAY
5. THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: CAST AGAINST EARTH: 3', EXPOSED TO EXTERIOR ELEMENTS'.
1", FORMED SURFACES: V
6, CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND
SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY
THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED.
7, CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURE'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH
AS PIPE SLEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE.
8. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 30 INCH LAP. PROVIDE
CORNER BARS
9. CONCRETE SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IS NOT PERMITTED FOR SLABS.
10. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC) SHALL BE TESTED TO ENSURE STRENGTH REQUIREMENTS ARE
MET.
11. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS.
A-l"'l-
Scott R. Sanders, P.E.
FL P.E. No. 64781
m
W
Q
Z
O
N
w
w
w
W CM
> 00
0)
� � M
W W U.
W
Z U
W
a a
N
CD �
L0 LL
W Z
C7 O
a �
� a
DATE: 7/14/17
SCALE: NTS
JOB NO.: NA
DRAWN BY: SRS
CHECKED BY SRS
SHEET NO.
1 of 4
Fine COP7A
12" OVERHANG TYP.
12" O�
ROOF SHEATHING PER SPECS.
VALLEY SET FRAMING
PER TRUSS MANUF.
0VERFRA114/NG DETAIL
SCALE: N.T.S.
PRE-ENGINEERED
TRUSSES @ 24" O.C.
WEST ELEVA TION
SCALE:1l4"=l'
NORTH EL/A TION
SCALE: 114"=l'
FASTEN EA. VALLEY TRUSSES
THROUGH SHEATING TO TRUSSES
BENATH W/ LSTA18 OR MTS16 TYP.
2x6 W/ 2 -4.
"X4" LAG SCREWS
SPACED 24" O.C. TO TOP CHORD
OF EXISTING TRUSSES
PROVIDE ONE AT VALLEYS AND
EVERY 8'-0" MAX.
EX. TRUSS TAILS
TO BE REMOVED
_ EXISTING WALL TO REMAIN
ry Ms. '
19
IPA
EAST ELEVATION
SCALE: 1/4"=l'
CONNECTOR LEGEND
86 UPLIFT
2 CONNECTOR TYPE
NUMBER OF CONNECTORS
CONNECTOR SCHEDULE
07-14-17
D.
I.F1/F2
MFG'R.
CONNECTOR
LATERAL
UPLIFT
FASTENERS
FLORIDA
APPROVAL
#
STRUCTURE
TRUSS
A
SIMPSON
HTS20
1,007 1,007
1,450
12
10d
x1-1
2"
12
10d
xl-1
2"
10456
13872
Al
SIMPSON
HTS20
1,007 1,007
1,450
12
10d
xl-1
2"
12
10d
A-1
2"
10456
13872
A2
SIMPSON
HTS20
1,007 1,007
1,450
12
10d
xl-1
2"
12
10d
xl-1
2"
10456
13872
A3
SIMPSON
HTS20
1,007 1 007
1,450
12
10d
xl-1
2"
12
10d
x1-1
2"
10456
13872
A4
SIMPSON
HTS20
1,007 1 007
1,450
12
10d
A-1
2"(12
10d
x1-1
2"
10456
13872
A5
SIMPSON
HTS20
1,007/1,007
1,450
12)
tOd
x1-1/2"(12)
10d
x1-1/2"
10456
13872
A6
HTS20
1,007 1,007
1,450
12
10d
xl-1
2"
12
tOd
x1-1
2'
10456
13872
GRA
SIMPSON
(2)HTS20
2.253 2,253
2,900
24
10d
xl-1
2"
24
10d
xl-1
2"
10456 /
13872
J1
SIMPSON
LTS12
250
720
6
10d
xl-1
2"
10456
13872
J3
SIMPSON
LTS12
161
x —
10456
13872
J5
SIMPSON
LTS12
197
720
6
1od
1-1/2:
1D456
13872
J7
SIMPSON
LTS12
237
720
6
1od
xl-1
2"
10456
13872
KJ7
SIMPSON
LTS12
437
720
6
1Od
A — 1
2"
10456
13872
V20
SEE DETAIL
FOR STRAPPING
VA
1 SEE DETAIL
FOR STRAPPING
VB
I SEE DETAIL
FOR STRAPPING
VC
I SEE DETAIL
FOR STRAPPING
PRODUCT
MODEL NO.
MANUFACTUER
EVALUATION
AGENCY
PRODUCT
APPROVAL NO.
EXPIRATION
DATE
WINDOWS
SILVERLINE
ANDERSON
FL#14911 R7
8/3/2021
EXTERIOR DOORS
PLASTPRO
FL#15213.1
12/31/2018
GARAGE DOORS
DAB
FL#12698.7RO
7/21/2020
OFF RIDGE VENT / RIDGE VENT
SOFFIT
JAMES HARDIE
FL#13265
1/1/2018
SKYLIGHTS
SHUTTERS
ROOF COVERING
OWENS CORNING
FL#10674 R12
8/20/2017
STRUCTURAL CLADDING
JAMES HARDIE
FL#13223 R1
1/1/2018
C&C Va,d Wall Wind Pressures
170 C Risk Cat. It H<15 Ft.
Zone 4 Interior
Zone 5 Exterior
A) 1.0 SF +37Y-41.1
F) 10 ` l; °= +37:9/-50.5
13) 20 SF = 136.2/-39.4
1°) 20 SF=+36.2/-47.3
-(') 50 SF °-+33.9/-37A
( ) 50 SF _ +33.9/-42.8
D) 100 Sl,' = 1312/-35.5
11) 100 SF = 132.2/-39'.14
Garage Door thin 2' from corners
1) 9'k7' = +33.4/-37.1 K) lUx = +3Z.9/-35.6
12" OVERHANG TYP
1
Scott R. Sanders, P.E.
FL P.E. No. 64781
Pin,
Z
O
U)
w
w
`W
/
00
W
J
W
Uj
LL
Nw
ii
LU
Z
U
�AA
Y
_
W
N
0
W Z
0 O
NO
DATE: 7/14/17
SCALE: NTS
JOB NO.: NA
DRAWN BY: SRS
CHECKED BY SRS
SHEET NO.
aKt CaARACfE -ptit 2 of bb"
q,rjzr.LIt
-1 1 n,-4tt
(Ili v CL4 rrvauo) �7
77ut�tEx bLcf (1i+7V� DOUBLE TOP PLATE
7" .Lev f-laC-ftwf
(rt�wTA- ,�rlv • � rnQ�
GENERAL NOTES: ,
1. WEATHERING AREA IS NEGLIGIBLE
2, TERMITE AREA IS VERY HEAVY
3. THE FLOOR OF THE GARAGE OR CARPORT SHALL BE SLOPED W/ NATURAL CONCRETE OR PAINTED WTH A NONCOMBUSTIBLE MATERIAL.
4, ALL EXIT DOORS SHALL HAVE A LIGHT W/ A FLAT 48" X 48" LANDING:
5. ALL WOOD -FRAMING MEMBERS RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH FASTENERS OF HOT -DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. PROTECTION FROM DECAY SHALL BE
6. ACCESSIBILITY DOORS SHALL HAVE A 29" MIN. CLEARANCE.
7, THE SITE ADDRESS OR NUMBERS SHALL BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
8. ALL STRUCTURE FOOTERS SHALL BE A MINIMUM OF 12" BELOW GRADE,
9. FOUNDATION STEEL (#5 BARS) SHALL HAVE A MINIMUM OF 3" OF COVER,
10. A CONTINUOUS
11 UOUS PATH FROM FOUNDATION
U 1TON TO ROOF SHALL BE PROVIDED PER DETAILS AND CONNECTIONS SPECIFIED,
11. ROOF AND WALL COMPONENT AND CLADDING LOADS ARE SHOWN IN THE DESIGN CRITERIA,
12. SHUTTERS OR IMPACT GLASS IS REQUIRED FOR PROTECTION OF OPENINGS FOR THIS RESIDENCE PER SECTION R301.2.1.2 OF THE FLORIDA RESIDENTIAL BUILDING CODE.
13. INTERIOR AND BEARING AND NON -BEARING FRAMED; WALLS SHALL USE STUD GRADE LUMBER SPACED AT 16" O.C_
14, FRAMED BEARING WALLS SHALL BE BRACED WITH 2X4S 0 A MAXIMUM OF 8' O.C.
15. FRAMED WALLS HIGHER THAN B'O" SHALL HAVE A ROW OF FIREBLOCKING AT MID -HEIGHT OF WALLS.
16. R 1 ROOF SHEATHING
HEA HiNG SHALL BE "CDX AN
17. ALL GYPSUMA � D HAVE A SPAN RATING OF 16/24 AND NAILED WITH 8D RING OR SCREW TYPE NAILS (2 /� X .131") AT 4" O.C. ON THE SEAMS AND 6" O.C. IN THE FIELD:
BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO ASTM C36, C79, C 475, C514, C630, C931, C960, C1002, C1047, C1177, C1178, C1278, C1395 OR C1396 AND SHALL BE IN INSTALLED IN ACCORDANCE 1
702.3 OF THE CURRENT FLORIDA RESIDENTIAL BUILDING CODE, ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C557.
18. ACCESS OPENING SHALL BE A MINUMUN OF 16" X 24" AND SHALL NOT BE UNDER AN EXTERIOR DOOR OR LOCATED BEHIND AN EXTERIOR FIXTURE.
19. ALL NAILS SHALL BE HOT DIPPED GALVANIZED OR BETTER.
20, ALL SIMPSON FASTENERS SHALL BE Z-MAX WITH HOT -DIPPED GALVANIZED COMMON NAILS OR BETTER.
21. ALL BEARING WALLS SHALL HAVE A SIMPSON SPH4/6 PLACED TOP AND BOTTOM OF FRAMED WALL AT 16° O.C.. HEADERS OVER 4' SHALL BE STRAPPED TO JACKS W/ SIMPSON MSTA24 AT ENDS W/ 8-10d NAILS PER SIDE. H
STRAPPED W/ SIMPSON LSTA18 W/ 7-10d NAILS PER ENO, EACH JACK SHALL HAVE A H2.5A 0 THE BOTTOM PLATE.
22. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ROOF PITCH,
23, NO SCREWS SHALL BE USED IN THE PLYWOOD SHEATHING OR WOOD MEMBERS OR ANY SIMPSON PRODUCTS UNLESS SPECIFIED IN THESE PLANS OR FROM THE MANUFACTURER.
24. ROOF RAIN WATER SHALL BE DIVERTED FROM SEPTIC FIELD.
25, A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATEI
26, CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12" AWAY FROM BUILDING WALLS.
27, IRRIGATIONISPRINKLER SYSTEM INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 12" OF THE BUILDING WALLS.
28, TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" BELOW FINAL WALL COVERING.
29. INITIAL TERMITE TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE..
30, SOIL DISTURBED AFTER THE INITIAL. TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED OR FORMED.
31, BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC. SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL E
SOIL AFTER THE INITIAL TREATMENT,
32. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED.
33. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT.
34, SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 12" OF THE STRUCTURE WALLS,
35, AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SW
36, ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT,
37. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE OF COMPLIANC
HAS REEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT OF AGRICULTURE AND C
38, AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW AND WITHIN 12" OF THE BUILDING, THIS INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, FORMS, SHORING, OR OTHER CELL
39. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED WITHIN 15OFANY BUILDING OR PROPOSED BUILDING.
DOOR AND WINDOW HEADERS
TO BE 2.0E 5 4'x11 T" PARALLAM;
(1) STUD FOR OPENINGS <6'
(2) STUDS FOR OPENINGS 6' TO 10' -
(3) STUDS FOR OPENINGS 10' TO 16'
SEE NOTES FOR OPENINGS >16'
LSTA24 @ EACH JAMB STUD
TO HEADER TYP.
SIMPSON HTT5 CONNECTOR
W/ 518" ANCHOR BOLT
EA. SIDE OF JAMBS
AND WHERE SHOWN
6" 3,000 PSI CONCRETE
ON 6 MIL VAPOR BARRIER
W/ TERMITICIDE TREATMENT
6X6-10/10 WWM
TESTED AND COMPACTED SOIL
BEARING CAPACITY 2,500 PSF
n ,,
P� PaS��J E,( L_r-j4tCA_�_ 56R-Ulz& u,�CC�2�rpb
Ae%D CAko&i 6td?uIG.t ZU 10 57A&&l_
2
r
*-J Q
fof: �twi1
n
If 1
At 0)1/' O z/b
�p6+IMl>
C3 1
SL:8 �.ru l �thli
wis
�G
F.OQ
PRE-ENGINEERED TRUSSES
7/16" APA RATED SHEATHING
W/ 8d RINGED NAILS @ 4" O,C, EDGE
AND 6" O.C. FIELD
25-YR. ASPHALT SHINGLES
ON (2) LAYERS OF 30# FELT
SEE CONNECTOR
SCHEDULE TYP.
12 2X4 NAILER FOR SOFFIT
3 ATTACH W13-16d NAILS
@ EA. STUD
1X6 FASCIA BOARD
> -�- ON 2X4 SUBFASCIA
VENTED PLYWOOD SOFFIT
W/ 12" OVERHANG
2X4 NAILER @ 24" O.G.
W/ 4-16d EA. TRUSS TAIL
AND 2-16d TOENAILS @
WALL NAILER TYP.
HARDIE SIDING APPLIED PER
MANUF. REQUIRMENTS OVER
30# FELT TYP.
/- 2X6 WALLS W/ STUDS @ 16" O.C.
W/ SP6 TOP AND BOTTOM AND
%2' CDX W/ 8d RINGSHANK NAILS
@ 6" O.C. ON EDGES AND'
6" O.C. IN FIELD TYP.
5/8" ANCHOR BOLTS
@ 24" O.C.
- P.T. BOTTOM PLATE
IN
RS
: N.T.S.
DESIGN PARAMETERS FOR WIND LOAD_ COMPLIANCE
1, BUILDING CATEGORY II
2. FLORIDA BUILDING CODE RESIDENTIAL 2014
3. BUILDING DESIGN IS ENCLOSED
4. MEAN ROOF HEIGHT IS < 15'
5. ROOF PITCH 3/12
6. INTERNAL PRESSURE COEFFICIENT +/- 0.18
7. WIDTH OF END ZONE A = 4.8'
8. WIND SPEED: (Vuit) 170 MPH 3-SECOND GUST
(VQsd) 132 MPH 3-SECOND GUST
9. WIND EXPOSURE CLASSIFICATION: D
10. ADJUSTMENT FACTOR FOR EXPOSURE & HEIGHT = 1.21
11. COMPONENT & CLADDING WIND PRESSURE ON ROOF:
ZONE 1 = NA
ZONE 2 = NA
ZONE 3 = NA
12. COMPONENT & CLADDING WIND PRESSURE ON WALL:
ZONE 4 = SEE TABLE
ZONE 5 = SEE TABLE
13. COMPONENT & CLADDING WIND PRESSURE ON SOFFITS (FULLY CLOSED):
ZONE 2 = +/- 59.8 PSF
ZONE 3 = +/- 59.8 PSF
14. LOADS:
FLOOR 44 PSF
ROOF/DEAD 20 PSF
ROOF/LIVE 20 PSF
WALL 18 PSF
15. SHEAR WALLS WERE CONSIDERED
16. A CONTINUOUS LOAD PATH WAS PROVIDED
17. COMPONENT & CLADDING DETAILED
18, MINIMUM SOIL BEARING PRESSURE IS 2000 PSF
FIBERMESH OR
WELDED WIRE MESH
SEE FOUN, NOTES
#5 CONTINUOUS
FOOTING REBAR
(2) #5 BARS
�
(2j#5 BARS CONTIN.
6? T
• IF.
rpl 1 1 R
-
`"C",,'���-5:`-_I�FIBERMESH
OR W.W.M.
29'
TYP. EXTERIOR CONT.
F1 MONOLITHIC
TYP. EXTERIOR CONT
F2
FOOTING
CURB MONO -FOOTING
145 BARS CONT.
14" FIBERMESH OR
FIBERMESH
WELDED WIRE MESH
OR W.W.M.
c
(2) #5 BARS CONTIN.
I
20"
F3 STEPPED INTERIOR
MONOLITHIC FOOTING
F4
TYP, GARAGE RECESS
MONOLITHIC FOOTING
4" I
FIBERMESH
OR W.W.M.
145 CONT.
3" MIN. COVER
F5 TYP. THICKENED EDGE
MONOLITHIC FOOTING
FOUNDATION NOTES
1. SOILS SHALL BE TREATED.
2. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM -1557 (MODIFIED PROCTOR).
3, FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2500 PSF.
4. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS.
CONCRETE NOTES
1, CONCRETE WORK SHALL BE
IN ACCORDANCE WITH THE LATEST EDIT{ F 30 P EDITIONS CI O A 1 "SPECIFICATION FOR STRUCTURA
L
CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE STRUCTURAL
CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN
28 DAYS OF 3000 PSF. UNLESS NOTED OTHERWISE. CONCRETE. WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR
MINUS ONE INCH.
2. PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AR CONDITIONED SPACES & GARAGES.HOLES IN VAPOR BARRIER ARE
NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS.
3, ALL REINFORCING SHALLCONFORM TO ASTM A615 FOR GRADE 60 STEELWELDED WIRE MESH TO CONFORM TO ASTM AA-185.
PROVIDE CHAIRS & BOLSTERS. BOLSTERS TO HAVE PLASTIC COATED LEGS & FEET OF EXPOSED TO EXTERIOR ELEMENTS)
ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB, LAP JOINTS AT 8" & TIE.
4 WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A185 AND SHALL BE ADEQUATELY SUPPORTED @ 3'-0" O.C.
EACH WAY
5. THE MINIMUM CONCRETE COVERAGE SHALL. BE AS FOLLOWS: CAST AGAINST EARTH'. 3", EXPOSED TO EXTERIOR ELEMENTS:
V, FORMED SURFACES:V
6. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND
SPECIFICATIONS ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY
THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED.
7. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURE'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH
AS PIPE SLEEVES, ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE.
S. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 30 INCH LAP, PROVIDE
CORNER BARS
9. CONCRETE SHAH HAVE 314" LARGE AGGREGATE. "PEAROCK" IS NOT PERMITTED FOR SLABS.
10. ALL. CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC.) SHALL BE TESTED TO ENSURE STRENGTH REQUIREMENTS ARE
MET.
11. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS.
c R. Sanders, P.E.
FL P.E. No. 64781
•
r
a
r
r
r
•
•
•
DATE: 7/14/17
SCALE: NTS
JOB NO.: NA
DRAWN BY: SRS
CHECKED BY SRS
SHEET NO.
of
Scanned by CamScanner
FiW Cg :A
30' Sp n or less
'
50,
to pan
SpreE der Bar '
60 degrees
or less
Tag line aie� 1/2 span
Tag line �� .,pprox 2/3 ta,I�'
approx.
1/2 of Span.
REFER TO BCSI
REFER TO BCSI
Truss must be set this way if crane is used.
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Insist crane operator sets truss this way.
' MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
• SETTING. REFER TO ENGINEERING DRAWING
A TO DETERMINE IF MULTIPLE PLY.
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
Ai are installed. A
•
Q Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
TYPICAL END DETAIL
3 rr—
!! IMPORTANT SAFETY NOTE H
1) Building Component Safety Information (BCSI) guide recommends that trusses 60' span and over should be
sheathed as they are installed. They may require complex temporary bracing. Consult a Professional
Engineer. Consult BCSI documents.
2) Truss of this size can be extremely dangerous during installation.
3) Extra care must be taken by the truss installer.
4) BCSI should be studied by truss installers before truss installation.
CORNER DETAIL FM I
oVEIUUNCS rat s,pm, CAMny
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
FABRICATION AGREEMENT'
TRUSSES CANNOT SE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Installed Is:
t; Trusses will be made In strict accordance with this truss placement diagram layout,
which is the sole sutho(Ity, for determiningsuccessful fabrication of the trusses,
2, All dimensions In this layout have been verged by the undersigned.
.3. Unless written notice Is provided by csdhled mall to Chambers Truss within ten (10)
days of delivery the undersigned agrees that no backchargas will be allowed. In the event
such written notice is furnished Chambers Truss shall have three (3) business days In which
to begin repairs required, or to substitute othectrusses, at Chambers optin,
4. The undersigned acknowledges receipt of "BCSI 1.03'summary sheet by'IPI & WTCA.
5. Delivery Is to job site. It Is the buyer's'responslbigry to make the job alto suitable for
delivery. chambers Truss has the sole authority to determine the suitability of the job site or a
portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only.
The buyer is responsible for additional delivery expenses If Chambers Truss has to redeliver
because job sea Is not prepared for delivery or buyer Is not prepared for delivery of trusses,
auger" responsible to Chambers Truss for towing costs due to she conditions.
8. pike as shown 11 paragraph 7 below Is subject to change If any changes are, made Iq
thls IeyouL A $50 per hour fee for revisions may be charged by Chambers Truss.
.7: This is a PURCHASE ORDER to Chambers,Tntss of the sum agreed to, or If nq;
agreement a reasonable price. Invoice will be made on delivery and paid within torms of neeii
on delivery. Invoice may. be made at scheduled date bf delivery If buyer cannot accept
delivery of fabricated trusses. The undersigned agrees to pay Chambere.Truss reasonable
atom -eye fee for collectlans In event of payment not timely made. 1.12 %per month servjce
change will be added for all sums not paid within terms. '
8. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein,
g, to consideration of Chambers Truss extending credit for this material the undersigned
unconcit8onally guarantees payment when due of any and all Indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned' agrees to pay such
Indebtedness Including attorneys fees, if default In payment for material be made by the
recipient.
'10. In the event of any stlgatlon condammg this agreement, me Items furnished hereunder
or payments referred to herein, tire. parties agree that vie sole venue for any such action will
be Saint butte County, Florida.
77. Design responslbllNes are par "National Stand' And Rocommended Guidelines On
Ra'spona blll0 For Conswctlon Using Metal Plate Connected Wood Trusses
ANSI/fPIMfTCA4-20o2"'
DATED �.
Aspwderbarmaybersg"per''BC I.Wlbpmverdkiwy&damgO..
Multiple ply trusses must be fastened togither per engineering
before they are set, failure to do so can result -in roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the responslblllty of the truss erector,
Study the contents of the Information packet included on delivery
before setting trusses.
Trusses mustbesetand braced perdeslgn tp prsverdiluN& daima9m
Trusses must be set plumb and square
Do not"set bunks or stack of plywoodroofing acause material
or any
se
,'other ofmcentrated loads on trusses, c
DO NOT SET TRUSSES USING THIS LA
1119E LAYOUT DELIVERED WITH TRUSSES TO SET TI
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Plerce; Florida 34982-6423
800-551-5932
Fort Pierce 772-466-2012 Fax 7714665.8711
Vero Beach 772-569.2012 Stuart 772-286-3302
DESIGN CRITERIA
LOADINGMESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
County
St Lucie
Building Department
St Lucie County
Wind Design Criteria
ASCE 7-2010
Wind Design Method
Main Wind Force Resisting
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L.
Floor
Top Chord Live
20
0
Top Chord Dead
7 4.2
0
Bottom Chord Live
'10 Non Concurrent
0
Bottom Chord Dead
5 3
0
Total Load
47 7.2
0
Duration Factor
1.25
0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
24'-3"
Building Type
Enclosed
Building Category
It: Non Restrictive
Exposure Category
C: Open Terrain With Scattered Obstructions
Miles from Ocean
5
Conforms to Florida Building Code 2001
R.D.L.=Restraining Dead Load
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 74507
SCALE: 1/4" = 1'-0"
46 total trusses, 19 unique designs