HomeMy WebLinkAboutFlorida energy effeciency code PP
PO!RM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City,State,Zip: FT. PIERCE,FL, Permit Number:
Owner: q . Jurisdiction:
Design Location: FL, ort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1432.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2
b.Frame-Wood,Adjacent R=11.0 208.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1753.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1753.00 ft2
6. Conditioned floor area above grade(ft2) 1753 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(151.4 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325
a. U-Factor: Sgl, U=0.54 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.250 14. Hot water systems
8. Floor Types (1753.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.970 ,
a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features
b. N/A R= ft2 None
c. N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 53.74
Glass/Floor Area: 0.086 PASS
Total Baseline Loads: 53.87
I hereby certify that the plans and specifications covered by Review of the plans and O1T$E STgT�
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance � �,,, ;. �.� V.
with the Florida Energy Code. O
PREPAR Y: Before construction is completed t"
DATE: this building will be inspected for 0 -iJ a
compliance with Section 553.908 -n
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. COD WE
OWNER/A N - BUILDING OFFICIAL:
DATE: ` DATE: I
1
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope',,leakage
test report in accordance with R402.4.1.2.
F`VC "� � �
7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
i
405 22014 1
PROJECT
Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1753 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1753 14024
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooledi Heated
1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes "Yes
2 WIC 63 504 No 0 1 No Yes Yes
3 MASTER BATH 56 448 No 0 1 Yes Yes Yes
4 M.BATH 61 488 No 0 1 Yes Yes Yes
5 LAUDRY 36 288 No 0 1 No Yes Yes
6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes
7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes
8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes
9 BATH 50 400 No 0 1 Yes Yes Yes
10 HALL 25 200 No 0 1 No Yes Yes
11 FOYER 92 736 No 0 1 Yes Yes Yes
12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood 1 Carpet
1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 _-__ 0 1
I I
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 _--_ 0 1 0
4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft2 --__ 0 1 0
5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 _-__ 0 1 0
I
7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
I
I
I
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insu i latio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0
8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0
11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0
12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1753 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type'
1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood
• i
4 Under Attic(Vented) M. BATH 30 Blown 61 ft2 0.1 Wood
5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood
6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood
7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood
8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood
9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood
10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood
11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood
12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
Ornt In Wall Type Space abe Ft_ n Et In Area o
Ahs
1 NE=>W Exterior Concrete Block-Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 ! 0
2 SW=>E Exterior Concrete Block-Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0
3 NW=>S Exterior Concrete Block-Ext IndMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
4 NE=>W Exterior Concrete Block-Ext InqMWSTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software (Page 3 of 5
I
i
FCARM R405-2014
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Belo w
Ornt 10Wall Typ Spacele Et In Et In Area
R-Valle_ 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0
6 NE=>W Exterior Concrete Block-Ext ImMDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0
7 SW=>E Exterior Concrete Block-Ext IndaINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0
8 NW=>S Exterior Concrete Block-Ext IndDINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0
9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0
10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
_13 NE=>W Exterior Concrete Block-Ext InEREDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
14 SW=>E Exterior Concrete Block-Ext InEEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None
4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in 1 ft 4 in None None
5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None
6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 806 ft2 806 ft2 26 ft 8 ft 11
INFILTRATION
i
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 l
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7
a
,
I
I
I
I i
I
I
t
7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
I
FARM R405-2014 j
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency. Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
/ --Supply— ---Return— Air CFM 25 CFM25 HVAC#
�/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ftz Attic 95 ftz Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan [ ]Feb Mar Apr Ma rj Jun X Jul X AugX]Se Oct Nov ]Dec
Heatin HJan [X]Feb Mar f Apr f May Jun Jul 4 Au [ ]SeP Oct Nov f X]Dec
Ventin Jan [ ]Feb X Mar [X]A r [ Ma Jun [ Jul [ Aug [ ]Se [X]Oct X Nov [�]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
i
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66•' 66
I
i
7/6/2017 2:44 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page'5 of 5
I
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City,State,Zip: FT.PIERCE;FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
7/6/2017 2:45 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
1