Loading...
HomeMy WebLinkAboutEngineering I PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 - 9888 E-mail pwelchinc@aol.com September 26,2017 Re: Randolph Re-Roof 698 Nettles Blvd. Jensen Beach, FL 34957 SCOPE OF WORK: Install new Metal Roof(Extreme Metal Fabricators,LLC "5-V Crimp"FL#17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE7-10 PROJECT DATA: BUILDING HIEGHT= 10'-0" A=3' MEAN ROOF HIEGHT=<25' ROOF ANGLE=4:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 IMPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 165MPH WIND VELOCITY V asd= 128 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE 1 (Field)=-40.3 ZONE 2(Perimeter/Ridge)_-68.0 _ ZONE 3 (Corners) _-99.8 ,Paid-Weeh Inc. Paul-Welch P.F. Reg.No.29945 September_26,2017 698 Nettles Blvd.Jensen Beach,FL 41f I METAL ROOFING ATTACHMENT REOUIREMENTS: Metal roofing to be attached with corrosion resistant Hex-Head wood screws#10 x 1 minimum with weather sealing washers(minimum.3/16"penetration through deck). Fasteners shall be placed through the panel ribs at 12"on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING= 16" O.C. ZONE 2 e :FASTENER SPACING= 16 O.C. (Perimeter/Ridge): ZONE 3 (Comers): FASTENER SPACING= 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT. :12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 &2: -93.5PSF/Zone 3: -101PSF Therefore O.K. UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1,and FBC 15074.5.2.Underlayment shall be Approved 30#Roofing Felt. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6"O.C. field for all zones. All work to be in compliance with product approval (FL# 17022.1),manufacturer's specifications, and the Florida Building Code 2014. Paul-Welch�lnc:. Paul Welch-P_-E;'Reg.No.29945 September-26,2017- 698 Nettles Blvd.Jensen Beach,FL 2 of 3 Tfp 2 I : iYP } -G R 0 2 (T-(P) S ROOF ZONE PLAN A=3' 010,02 ,03 ='ZONE DESIGNATION(TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF . SLOPES UNDER 3 VERT. :12 HORZ. r_ - P-�ul'Welch-Inc. Paul Welch P.-E. Reg._IvTo.--29945 Sep�emb 26,2017 = _ 698 Nettles Blvd.Jensen Beach,FL 3 of 3-