Loading...
HomeMy WebLinkAboutInspection Docs RECEIVED O AUG 14 tote professional Insulators of South Florida Permitting'Department St. Luciea County FTC Insulation Installation Certificate County To: St Lucie County Date: August 3,2018 Re: Lot/Block: Address: I Isabella Project: The undersi ned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R-Value: R 4.1 Rigid Board Polystyrene Other 2. Ceilings(level)have been insulated with: Spray-on Cellulose Thickness in inches: 11.1" X Fiberglass Blown Manufacturer. Chmatepro IRock Wool Blankets Density: Aluminum Foil R-Value: R-30 Polyurethane 10pen Cell SPF Ceilings(Inaccessible)insulated with: Spray-on Cellulose Thickness in inches: 9.51, X Fiberglass Blankets Manufacturer: Johns Manville Ignition Barrier Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Open Cell SPF I Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: Cellulose Loose Fill Open Cell SPF 4. Garage partition walls of A/C living area have X Fiberglass Blankets been insulated with: lRock Wool Thickness in inches: 3.5" Polyurethane Manufacturer: Johns Manville Spray-on Cellulose Density: ]Open Cell SPF R-Value: R-11 5. The following have been insulated: 1NYNNE BUILDING CORP. , ��- re General Contract/Builder Z zoos :o CBC1254041 •�VICompetency# +� hoitd. Professional Insulators of South Florida,Inc. lot% �slogs�i Insulation Contractor By: By: 1 11 �I i _ Planning &Development Services RECEIVED -� Building &Code Regulation Division 2300 Virginia Ave AUG L'5 7n18 Fort Pierce, FL 34982 Permitting De 772-462-2172 Fax 772-462-6443 st. Lucre county CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: 1710-0496 JOB ADDRESS: 1 ISABELLA LN PORT SAINT LUCIE,FL 34952-2849 BUILDER/CONTRACTOR: MNNE DEVELOPMENT PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #:JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 225LF Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: 100 Date of Treatment: 05-02-2018 Time of Treatment: 2:30 Footing Slab 1't Treatment 1st Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1't Treatment Re-Treat Re-Treat Other xx erime' ter for n nspection 1st Treatment Re-Treat !3itinature of Ext inator Date Note: There must be a completed form for each require treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each ins ection or the scheduled inspection will fail and a re inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Cert/ficates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment j Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 � 1 „«emu..Y•�i s R i�ti�ta Wc�i���I�Ji��tiWi-' .. Planning&Development Services Building&Code Regulation Division 2300 Virginia Ave,Rm 201 • R • A Fort Pierce,FL 34982 RECEIVED Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM AUG 0 3 2018 House Infiltration Test Certification ST. Lucie County, Permitting Prescriptive and Performance Method Date: — �� Permit#: / -71 c O y9[S Contractor: C)•.i d eo- I Job Address: J- Construction: New Construction—Complete ( ) Existing—After Addition House Infiltration Test Results SLC Climate Zone 2 CFM(50)= 19 Test Date: r f J Volume= (- 0 ACH(50)=CFM(50)x 60/Volume= y , Me anical Ventilation required less than 5 ACH Passing results must be&ACH(50)or less )Pass ( )Fail FBC,Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1,2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code,Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro Duct Services Address: 1915 Rio Vista dr., Fort Pierce, fl. I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Faurot License/Certification#: 5050122 %I I I Rl C11O1> �19$' i4•Allar�a7 RECEIVED ,. •..: ; iiir r a JUL 1 Z 200 11 � . 2 Permitting mlttin county Lucie f bf,3(Y- ;TeMj�-br&Y'PdVnr P.0te-aSe , Q it m0m.b& PA&-CA-dr : THE UN)ERSIGNED HEREBY REQUEST RELi:XtSE OF E.LEG"f C:AL POWER TO THE ABOVE DESCMED PROPERTY,FOP,A,PMOD.NaT:TQ pC+rE U T ixRTY E} f Al!S, F6RTHE PUi POSE OFTBTING SYSTEMS .ANC?EQUIPMENT IN PREPARAITON.FOR A FINAL.INSP.ECMN. -Rq CONSTDp RATION OF APPROVAL OF THE U �iE l i l '�A 90 .ffi�aE ANb A: -AS FD1I_flws- 1. T Ws twgibray pom release is.regesbed for the abevg stated pt o�ody,a€�d there WM be ft occupan4 of any Wpp ,o6ier than'that OrMit ted by roPistru�cd'on during this erne pendd. Z. AS witness by our sigrtat ohs,we he 0y agree 1b abfde by all i ei=amd-conditions of tins agr�emerit, lncht09 Suilding Divisioh,Pblicy,which is incorporated hox,&'by. reference. g. All candit7ons:and iulremefsts listed in the el�ed doojmeM eTId"ReqLfiMentry For 30 Day Power for'T,9tifg"Mve-been'futhfied*arid.tiro premise is ready for compliance,inspection. 4. All requests for aft adensiori beyopd 30 days must burl*made in wri€lhg to.the.Building Of ial st ffdng the r n'for the reg Est Aoiiver may be r m6Ved'fcocn the site.and/br a stop W.o*.Order issued if the Flnai'frispedzor nas riot beer►approved wabin 36 days. A fee df$100.00 will lie regi�red tD iift _ the Stop Wbrk Order. WE HEREBY RELEASE-AND AGREI=TO HOLD HARMLF,% ST. LUCIE COUl�1 Y,AND THEIR EMPLOYEES FROM ALL LISILI TIES ANO t- AIMs AN•OF Y TY- PE.OF NATU3I~WHICH.MAY ARISE NOW OR IN THE FUTURE OUT Ot=T TRANSACTION, INCLUDINO-AfalY'60 AG,1= I MAY SE INCURREDIDUF TO THE D NNECWN C�E1M RIC'AL POWEk IN Ti iF 50q-T OF VIOLARION 01xT I P OWNER`SIi;itr ITRE DATE rr c DA1 EL�CTRYCAL CONTRAMA MGNA'WAE DATE i L99-A Z000/ 000d LL L Il 999LSL8ZLL -WM A Zti=80 8 L Z L-LO Planning &Development Services J P ° Building &Code Regulation Division M411111 110 1 2300!Virginia Ave • Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: � 2 M 6 JOB A DDRESS: -sC l �► J L �''���L i BUILDER/CONTRACTOR: l ion. PEST CONTROL CONTRACTOR: EVICT-A- UG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #:JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for j subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: �� DOMINION 2L q � Chemicals used: Percentage of solution: •05% Total gallons used: C� -- Date of Treatment: - -�- _-Time of Treatment: Footing Slab 15t Treatment 15t Treatment Re-Treat Re-Treat D ' wa ryy R Pools Treatment 15t Treatment Re rest Re Treat T 7 Other st Perimeter for Fi Inspection 1 Treatment r Re-Treat Signature of Ext ins r Date Note: There must be a completed form for each required treatment or re-treatment and this form must be on the site to be picked up by the Inspector at time of each inspection or the scheduled Inspection w111 fall and a re- fee charged. IFBC104.2.6 Certificate of Protective Treatmentforprevention of termites A weatherresistantjobsItepo shall be provided to receive duplicate Treatment Certificates as each required protective treatment is corf providing a copy for the person the permit is issued to and another copy for the building permit fi/es gall Certificate shall pro vide the product used, Identity of the appllcator, time and date of the treatment, treated, chemical used,percent concentration and number of gallons used, to establish a verifiab/ on protective treatment. If the soll chemical barrier method for termlte prevention is used, final be completed prior to final building approval, St Lucie County requires for the final inspection for CC, a permanent 5tilclk the electrical passel box cover,, Visiting all the treatments and dates of app' Rariscd 7/24/2014 1 I I cm, . Avg IKELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, 'INC. MARTIN(772)337-7755 .-.P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561) 845 7445 www.ksMengineering.net - MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LU A (772) 229=9093. C.A.:5693 FAX '(772)589=6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 6, 2017 KSM JOB# : 173680-1d/S8/6t , PERMIT# 1710-0496 CONTRACTOR Wynne Development JOB LOCATION 1. Isabella.Lane Spanish Lakes'1 Port St Lucie, Florida ITEWTESTED Compacted Foundation Fill TEST LOCATION * PEN DRY MAX_. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE COMPACTION 1. S.E. 0" 12's 39 106.2 109.4 97.1 2. S.W. 42 107.8 " 98.5 3. Center 38 105.7 96.6 4. N.W. 36 104.7 95.7 5. N.E. 41 107.2 98.0 Soil Description: Tan & Brown Sand with 110.0 Traces.of Clay and Shell Fragments w In Place Moisture: E I I I I I I 8.8 Percent I I I I I ! G 109.0 Optimum Moisture: H 12.0 Percent T Max. Dry Density: p I I I I I I 109.4 P.C.F. 108.0 i--.._.. _..j_.._..j_..._..�. j_.._,. C @.Test Locations The Density & Penetrometer F Readings Indicate the - 107..0 9 Degree of Compaction Meets p Minimum eEteAef buo""i R for StqR Y 1, I I t Natural Grade. 9 10 11 12 13 14 15 . pe kfu Submitted: 11/7/1• 68366 • e Moisture-°o ei p • ! a ,,;'� -ram el i�► EQF r r t,• CO g- .'. . R10P. `, Fax i l^�a ',Le t�,�ounty Building Department JAN 0 9 2013 Email t".4 1 tsiilakes.com d� �oe�a��4 Permittin St. g t'�'i��rtrp Lucre C t oua I Rona6.G. Keller, RE.:37293!S1 Lie. No.:860 ! Julie E. Keller, RE.:683 y� I ' 12/07/2017 17:31 _772589640 KSM ENGINEERING PAGE '03/05 KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MAR71N (772)337-7755 pQ, �QX 7$-1377, SEBASTIAN, FL 32978-1377 MELR"CRNE(321)789-8488 PALM F35ACH (561)$45�-7445 www.ksmengineering.net _8 URNLUCIE(772)768-8488 FAX(561)845-8876 E-Mail: KSMC??KSMENCINEERiNG_NET FAX(772)589-64-69 O.A.: 5693 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 6, 2017 KSM JOB#: 173680-1d/SS/ct PERMIT# : 1710-0496 CONTRACTOR Wynne Development � JOB LOCATION 1 Isabella Lane A .Spanish Lakes 1 DEC 07 Port St Lucie, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAK DRY PERCENT ' OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.E. 0" - 12" 39 106.2 109A 97.1 2. S.W. if 42 107.8 98.5 3. Center ti38 105.7 96.6 4. N.W. 36 104.7 95.7 S. N.E. 41 107.2 98.0 Soil Description: Tan & Brown Sand with 110.01 Traces of Clay and Shell Fragments W I I I I i I In Place Moisture: E I I 1 I ! 8.8 Percent I I I I I I H 109.0 L.._..� Optimum Moisture: I I I I I 12.0 Percent T Max. Dry Density: 109.4 P.C.F. 108.0 C Qa Test Locations The I I I I 1 I Density&Penetrometer F I I I I i Readings indicate the . 107.0 _.._.. .._..�.._..�.._..I_.._..I_.._.. Degree of Compaction Meets D li�tir>Iirn�j� $ R .,,� R I�! �'• for 'F •,. !V t&,NaturatGrade. Y 106.0 4--.._..� .._..�..�..�.._..�.._.�_.._.., r 9 10 11 12 13 14 35� tfu Sa tteV: 2 1 8 • Moisture-%of Dry Weight F ttr County Building Department Ema�% we shlakes.cor►'1 1, I Rr,�nalr7 CR. Keller.P.E.: 37293/Sl Lic. No.:860 / Julie E. Keller. RE.:68366 Planning &Development Services Building &Code Regulation Division • 2300 Virginia Ave Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: 10 l5 OB ADDRESS: F/- BUILDER/CONTRACTOR: dfle PEST CONTROL CONTRACTOR: EVICT-A- G TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: Date of Treatment: IZ Time of Treatment: W O O U-"'Footing _— - Slab - 1 Treatment -Ist Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-T t Other Peri er for Fi i-a-q pection 1st Treatment Re-Treat 1Z 2/ 17 nature of Exterminator Date Note: There must be a completed form for eac quired treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection fee charged, FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 I i 9 rJ -a. A KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377, jEBASTIAN, FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksniengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST.LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 $OIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 6, 2017 KSM JOB# : 173680-1 d/SS/ct PERMIT# 1710-0496 CONTRACTOR Wynne Development JOB LOCATION 1 Isabella Lane Spanish Lakes 1 Port St Lucie, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION * PEN DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE COMPACTION 1., S.E. 0" - 12" 39 106.2 109.4 97.1 2. S.W. 42 107.8 98.5 3. Center 38 105.7 96.6 4. N.W. 36 104.7 95.7 5. N.E. 41 1.07.2 98.0 Soil Description: Tan & Brown Sand with- 110.0 Traces of Clay and Shell Fragments W In Place Moisture: E I I I I I I 8.8 Percent G 109.0 Optimum Moisture: H 12.0 Percent T { Max. Dry Density: p 109.4 P.C.F. 108.0 -.._..� _..�.._..�.._..�. 1—. — - C @ Test Locations The Density& Penetrometer F Readings Indicate the 107.0 _..�.._..�. _..�.._..j_.._ .j_.._.. Degree of Compaction Meets p for�ma' � �'•, { { I { I 1 R 1660,?td►,latural Grade. 106.0 �-- 10" 9 10 11 12 13 14 15 s j'ctfu S ti:gu 'tte . 2/7�1 'ED. Moisture-% ECIEIV • • i v . LORD®. '';+ DEC 11 2017 Fax' Pt2f ' q0b County Building Department Emailta� tlpeh'i'shlakes.com Permitting Department St. Lucie County; FL Ronald G. Keller, P.E.:37293/St Lic.No.:860 / Julie E. Keller; P.E.:68366