HomeMy WebLinkAboutBuilding plansGulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 F. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick light textured
12
stucco on typical concrete
4 1SLOPE
block construction
Plnlsh Columns with 5/8" thick x 8"w cut
5/8" thick cut coral coral finished stucco bands
finished stucco bands
LEFT ELE\/ATION
IIEGRESSI
U
RIG. T ELEVATION
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411151.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
SLOPE 4
EGRES PER D
3
0'0" = Finished Floor
5/81' thick light textured
stucco on typical concrete
block construction
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
P g
Type
NOA FL
/
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
TEST
Expiration
Date
Design Pressure
of Approved Tests
1.2.3
#4
FLU I1499.2
Single Hung
Series 185
MI Windows
and doors
x 3 llPcane mi p n ton at meJc
om eac� corner and G o.e. therea�'ter througq �uck into solid
filled eMu wall maintaining min 2.5" edge distance m strict adherence
to the product approval.
± 60 sf
p
A
16-0330.02
Overhead
Garage Door
Model 824/811
T-4" max. width
IG'-o" max height
DAB
rota x ac to aorL eta ac of i coilwith
a a6 bar wrt. LF4 3/e' x C Win HLC alnve anchors at s' oc.
h 126'6iK x°0w 6ie*t�Wimeh.�eed°° di.tmx'. lint°° track to, buck
leg screws in each bracket mnteimne
inn d 1.6' edee distance - GC to strictly adhere to product approval
reside VIL' nut dasher on filler shafts.
10-9-21
+ 50.0/-60.0 sf
p
FLU 16614.1
Fiberglass
DesB
smooth Pro
Jeld-Wen
Elco 1/4" die. tapcon with min 1.25" embedment at 3" max
from co ners and m.5" o.c. max thereafter in head and Jambs.
+ 50.0 PSF
C
FLU 15332.2
Sliding Glass
Door
Series 420
MI Windows
and doors
L i4 x 3 cone w 1na uanatration at ` max.
rom each corner end -1' o.c. all aouDla row thereafter through
f T Buck into adid filled CMU wall maintaining min 2.5" edge distance
in strict adherence to the product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
ST
Ex iration
Date
Design Pressure
of Approved Tests
Mullions
FLU 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4" x 2 3/4" tapcons with min 1 1/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 PSF
-
Roof
FL# 11451.12
5V Crimp
Metal Roofing
Gulf Coast Supply
and manufacturing
2G ga. Sy crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with eaif sealing washer at 12" o.c. max skating over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and G" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" ox. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kagcan
Install using 2" x 2" battens at t" o.c. screwed to soffit framing using
# x 3" woodSsclews at each trusas. ils Install soffittwith 3/8"l a. to battens using
+55.0/-35.0 PSF
Hurricane
Panels
Flit 15014.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
12"
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL 411451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.26" ring shank nails
spaced 6' o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
4 1 SLOPE,
L■J�
5/8" thick light textured
5/8" thick x 8"w cut stucco on typical concrete
coral finished stucco bands block construction
R=AR
12
4 1 SLOPE
COVERED
PORCH
ELEVATION
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. In field. Attach
deck to trusses using attachment detail on this sheet \
ST. LliCTp rr/O'�vii:P�C
RF,VIENVE O
R NIYL 410E
REVI£tN'E Y
DATE J
PLAN'S PERMIT " ; BE KEPT ON JOB
OR NO INSPECTION WILL BE 11ADE.
l2„
.H.
O'-O" =Finis ed Floor
S OR ATTACHMENTS
E THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
THESE PLANS AND ALL PROPOSED WQhk
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE COOK
TERMITE TREATMENT REQUIRED
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
Q
2" x 4" top plate 1I 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" o.c.
base -board 11 [ / 2 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6"x6" 910/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
nterlor Non-Bearinq Partition
Braden It
Braden AIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
B
: (112) 281-8258
Fax
: (112) 281-8283
E-mall:
bradenaias'comcast.net
Stuart. PL
349% #AACOO0032
nits
W(gnne Building Corp.
Spanish Lakes
St. Lucie County Florida
SCALE: 1/4" = I'-O"
Z
ALL MANUFACTURES LABLES SHOVAi,G
U FACTORS AND SHGC COMpLiANC
WITH FBC ENERGY CODE MUST
REMAIN
INN ALL DOORS AND WINDOW
ONSARE AP
ni-n" = Finimhcrl Flnnr
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 165 mph ultimate
Mean Roof Height: 11'- 'r Roof Pitch: 4:12
Internal Pressure Coe Icient. ±O_I8
TOW0TCH
Subjectability to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3'-4" Wind Speed: I45 mph ultimate
Wind Exposure Classification: C
Adjustment factor for Exposure Height: 1.21 x 0.6 = 0.124 ASO design
Load Combination: ASCE 1-10 Section 2A DL+LL; DL+O.LWL; O.6DL+O.4WIL
Components E Cladding Wind Pressure (NET) Roof Zone: I. +20.L/-32.4 par
Roof Zone: 2. +20A/-51.0 psf
Roof Zone: 3. +20.6/-84.0 par
Components i Cladding Wall End Zone Width: 3'-4"
Components i Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 par
0 Roof Zone I
Wall Zone: S. +35.8/-41.8 psf
Walls
Components i Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3par
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
EM = Roof Zone 2
yes
Walls Zone 5
Are Components an Cladding Deter Provided? Yes
END ZONE
Minimum Sod Bearing Pressure:2,500 psi, Presumptive: X By Test: psi
This Building Shall Have the Following:
M = Corner Zones
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: --1-5 par FLOOR DEAD LOAD: 10 oaf
JOB ADDRESS
Model:
Date Drawn
REAR
5-9-I1
Drawn by:
PORCH
c.c.u.
LEFT
Checked by:
D.R.B.
Revisions
Sheet Comm #
I. 11S-IS8
OF 5
I /\ j� I
L O O R FLAN 4"
�FLOOR
Recess top plate
for steel support
Viax 3/8"d
angle
f- f� I �
C R A S P O SJ T D E T A I
see detail on this
ahset
\
TYPICAL NOTES: SCALE I/4" = I'-O"
N.T.S.
I. Contractor to verify ALL notes and dimensions prior to
36" high by 4" diameter
pproceeding with Work.
g
steel crash post, Floor
Flange with 4 - 3/8"
Steel countertop support angle
Install 6" from each end and
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
expansion bolts Into
one in center of
see angle detail
counter.
3. ALL Lumber to be used as Beam, Rafters, etc... to have
slab (3/8"t SO ksi steel plate)
a minimum 1,400 P.S.I. fiber stress.
6"
1/2" drywall
4. No dissimilar metals to touch.
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, Cont. tie beams etc., to ° -
Shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix-
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses With screws per FBC R102.3.5.
1. ALL wood in contact with concrete shall be pressure treated. ° 0-
S. ALL wall dimensions are nominal and not finished Wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12. Lowest finished floor to be set by Governing Building Department 6"
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
I6. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2
I-1. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R316 - see permit info box of code edition
18. Gyypsum board material shall conform to ASTM C36, C19, C4i5, C514, C630, C931
C960, C1002, C104-1,C1111, C1118, C1278, C1395, or C139b and shall be installed
according to
the following: (FBC R
Masonry Beam
Drywall
Location
Orientation
Framing
Max. spacing
I" x 6" P.T. Buck nailed to /
block with case hardened Halls
block
options for
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A13L.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C11-18 and Installed LA.W, manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members Installed
within floor -ceiling assemblies, roof -ceiling assemblies, Wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accomparliging smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" a.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Simpson HETA 20 or equal
hurricane
c(10) IOd x la 1/2 nailsuea 12
( 24" o.c.) supporting Max 4 I
Islolbs. uplift i
Aluminum Drip -
Edge d Fascia
2" x 6" Sub -Fascia
Kagcan full o vent vinyl soffit installec
using 1/8" die shank x 15" long galv.
roofing nails with 3/8" dia, head per
product approval -see chart sheet #1
5/8" thick light textured
stucco on typical concrete \
block constructionHA
°D
#5 bar vert. w/
30" overlap -
at each filled cell
d
TYFICAL SECTION
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
_and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (l) #5
bar cont. for bottom row over openings
1/2" drywall over I" x furringg
strips at IL" o.c. with R4.1 (i-foil
-insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R4011
and Mortar Jonts shall comply with FBC R60�.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(l) #5 bar vert. (typical).
`Max, spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
_I ..
14" x 14" Concrete footing
with (2) 45 bars cont. and #5
transverse bars at 48" o.c,
tom
Counter top - verifu type
with contractor
Base cabinet
2" x 8" wood studs
at 16" o.c.
2" x 8" PT wood plate
KITCHEN ISLAND FRAMING DETAIL
Attach buck to block wall with
1/4" die. Elco conic screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 6" PT Buck
or wall
B cries
#8 Wood screws thru jamb into buck
at each hinge and 15" o.c. max and
n P_ t_ n i l n t_ M CX)r prior to door attachment
NITS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
Install windows thru buck into
block with 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at ambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall ---\ \ Buck to be I" x 4" PT
P.T. Buck nailed to
block with case hardened nails
D e t a l l at W i n d OW S prior to window attachment
NTS
Install SGD thru buck into
block with 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
0 O Use 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment \
fixed door
sliding door
1 1/2"
Sllding Door Detail
At Masonry Wall NTS
Masonry Wall
cal Flooring
Install SGD thru buck into
block with 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
Window Schedule
Mark
Size
Rou h O en.
Window Description
PRE55URE ZONE
I.
4'-S'/e"x 4'-6 %a"
54%"x 54V'
Single Hung
ZONE 4
2.
6'-24'x 5'-3 %s"
15" x 63 4,
Single Hung
ZONE 4
3.
2'-2" x 3'-2%'
2lk2"x 38%"
Single Hung
ZONE 4
x 5'-3%'
38" x 63'/4'
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
nd mullions per elevations.
LL windows to withstand pressures in permit info box on sheet I
LL windows in bathrooms to be tempered
A I rough opening dimensions to be verified by contractor
wl h manufacturers specs prior to construction
Door Schedule
M
rk
Size
Rough Opening
Door Description
PRESSURE ZONE
9'-0" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
3'-0" X 6'-8"
41"%," x 83%"
Fiberglass Panel - Inswing
ZONE 4
6'-0" X 6'-8"
14" x 81 %;' .7% tin
Sliding Glass Door
ZONE 4
2'-0" X 4'-8"
Solid Core - Wood - 6-Panel -BI-Fold Finished 24" x 81 %2"
T-0 X C-8"
Solid Core - Wood - 6-Panel
5'-0" X 6'-8"
Solid Core - Wood - 6-Panel - BI-Fold
2'-8" x C-8" x 1 %,"
Solid Core Wood, Steel, or Masonite Door
2'-8" X 6'-8"
Solid Core - Wood - 6-Panel
2'-6" X V-8"
Solid Core - Wood - 6-Panel - Bi-Fold
ALL
b
GARAGE
WITHSTAND
All
wi
Exterior doors to Withstand pressures stated in permit info
x on sheet #1
DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
rough opening dimensions to be verified by contractor
h manufacturer s specs prior to construction
Verify attachment
hole location with GC
prior to fabrication
3/8"
steel
COUNTER TOP BRACKET DETAIL
3S'-O"
Total Cubic Ft = 14,02-'
Square Footage Breakdown
Total A/C Space = I,153 sq, ft.
Covered Porch Total = 212 sq. ft.
Garage - 459 sq. ft.
Under Roof Total = 2,484 sq. ft.
Scale : 1/2" = 1'-0"
12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied 1
,..4.. i + it ni....m
�$.S
STRLU(
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL 9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
IC
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II.
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
13
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
BUILDING CONSTRUCTION
6
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15
ATTENTION OF THE ARCHITECT.
16
8.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
11
FOLAD/4TION FL/4N
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, 8
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for veriflcation of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect Shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and I #5 bar vert. at 4811
o.c. max. Provide (1) filled cell on each side of openings up to 5'-11" wide.
Provide (2) filled cells on each side of openings from _Cu to 91-111,
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24' o.c. unless otherwise noted (see section)
L Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of Soil test to architect for review prior to construction
8. ALL Reinforcing Steel Shall be grade (0, meeting ASTM A—l6 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
U5 bar vert. w/
30" overlap SEE TYPICAL
at each filled cell �ECTIONS
_21
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
1 =I 14% x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
I / TYPICAL FOOTING DETAIL
J SCALE 1/2"
4" concrete slab with fibermesh OR
6 x6 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
10" __�(2) #5 bars cont, bottom steel
12"
DETAIL AT 6" GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bars Vert. tied
into lintels above
Top of footer
19" below finished floor
1I"
Verify house slab
height in field
Thicken edge to 8"x8"
with concrete and
one U5 bar continuous
GRADE
#5 bar Vert. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
45 bar in curb \
— 30"x30"xl6" concrete
III
column footing With (4)
III 45 bars each way
3' 30'
.... All
COLUMN FOOTING DETAIL
SCALE: 114" = 1'-0"
FOOTING
SCHEDULE
MarkI
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 14"D
MONOLITHIC FOOTING
- 6" STEP DETAIL ON THIS SHEET
SO"
x 30" x 16"D
COLUMN FOOTING WITH (4) 45 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
FS
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB ® 0'-0"
F6
12"W
X 18"D
MONOLITHIC FOOTING
- 6" STEP DETAIL ON THIS SHEET
4" concrete slab with fibermesh OR
6"x6" 410/10 WWM on 10 and Visqueen over
clean compacted termite treated fill
E DETAIL
SCALE 1/2" = I'-0"
TYPICAL
rIONS
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
_n„ 9 F F gil
" I1
lii
lii'
14% x
footing
14"d
with
concrete monolithic
(2) 45 bars cont.
14"
GARAGE CURB DETAIL
��
4" concrete slab with fibermesh OR
611x6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
2" x 6" PT wood secured with \
3/8"dia. x 6" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
PERMIT INFO BOX ON SHEET 41. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
1*5 From Footing To Beam Each. Filled Cell Masonry Column With One
Conc. Fill To Be 3000 PSI
See Floor Plan For Location 45 From Footing To Tie Beam
r Double Filled Cell Column
a-
NTS
N17-
�n Bri
10" (2) U5 bars cont. bottom steel
12"
DETAIL AT 9" GARAGE STEPDOWN N R
Conic. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell C DIUmn
NTS
i
12"
T_10Y2" 12" 8'-10%2"
N
°
E El 1100 ._�
__i_i.
601 1 1 100
°T
_
_ _ _ _ — — —
_
_
FI
�� Filled cell
under
I
girder above
o
I FI
�
I
0
I
- p Rear Porch Slab to
FI
❑
L
W - be poured separately
from House Slab.
I
N
,
O I
Thicken footing to
E
24"w x 14"d x 24"1-
under felled cell
-
❑❑
° ❑ E❑�
EE
under girder bearing.
m
r --
I
---
FI
`�
— —
mtoo
qova
Rear Patio/Slab to
be flush with bottom ofsliding
door recess.
Slope I"
Vnp
❑
4" concrete slab
with flberms
�m
I
601x6" #10/10 WWM
on 6 mil
Visqueen over
H.B.
U U
I
clean compacted
termite
treated fill
�I
E
iL
WASHER DRYER
FI I
F_
I
IE
�I
I
1
—i
1
I
1
—i
_
—i
I
O
Q:J IE
Ll
°
❑
�
I
FI
p
I
E
r
I
EI
IE
o
Dw
TFRMITF TRFPATMFIl1T RF0UIRFD
o
o o
_
EI
\
IE
4 concrete slab with
fibermesh OR
FI
6 xC #10/10 WWM on 6
mil Visqueen over
clean compacted termite
treated fill
1
E
MNON-VENT
❑°
O
I
REF.
H.B.
I
O SIB" CLEAR
� OPENING
OO
r---
---
A/C
FW.H.�5
n11ths sheet
a detail Ballard
I
>
1=i
CD
�I
W
CL I
1Q
O I
FI
❑
Meter
and panel
m
J
either side of
ouse field verify
I
I E
E UDL
BE
N
service location
1
E—
-- --a-
--
E
IQ
W
E
I
—
4" std
101-
O
I
01
ILLN
E
-
❑
L
Q I
a I
5
❑o
— —
— — — — — — —1
t — —
—
❑
E
1.5" Recess for O 1 1 EE
— EO O 1.5"
Recess for
E 119
DE
Garage Door
;a
Garage Door
9'-0" 2'-8"
C-4"
-8"
91_01,
2'-8"
3]
35'-0"
1/2" = 1`0"
SCALE 1/2" = I'-C)"
Simpson HETA 20
hurricane anchor at each truss
ROOF SHEETING
ATTACHMENT DE7AIL
I. Minimum Nall Size =
8d ring
shank (min. 2.5"
long)
2. Minimum Screw Size
= #8 x
2"
3. Minimum Sheathing Thickness
19/32" COX
PI wood
4. Use nails or screws
based on pressure for
for
roof stated
3
in permit info box
on these
plans zone
Keg
Area
Edge
Field
Fastener
Max.
Pressure
Zone I
6"
6"
Sd ring shank
45 psf
Zone 2
4"
6"
8d ring shank
i6 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
6"
6"
#8 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Provide #5 bare with min. 48 bar
diameters overlap Into beam. Tie
filled cell steel into continuous
beam block steel. \-�
Provide Cast -Crete
SUB-OB/OT precast -- -
lintel set in mortar _ I
Min. B" Bearing -- - -L - - -
Verify with Plan
12"x 12"
1 Column Block
v#'I
� Rebar
Rebar 78Br Dla.
Min. Overlap
to Lintel Attachm&nt
BEAM
SCE-IEDULE
Mark
I Size and
Descrl tion
BI
Two rows of beam
continuous in each
45 900 bend bar
block filled with concrete and 1 45 bar
row. Hook vert, bar over top bar with
with a 10" min. lap at top bar.
NTS
Provide #5 bar set in pre -cast ROOF F T,4N Scale
lintel into beam where length of
the opening calls for it. — Overhan S At I '—OII Unless Otherwise noted On t
e PT Buck
ed per jamb
into filled a
4" Pre -cast
Sill �
— Roof pitch at 4:12 unless otherwise noted on thl
_-- — Truss shop drawings to be provided by manufactL
—;� — Any changes to this plan shall be submitted to 1
` architect for approval in writing prior to startln(
— ALL TRUSS TO TRUSS CONNECTIONS BY
I TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prior
to construction for layout and uplift verification
Poured Filled Cell — Contractor to provide for Form Board Survey
Form Board Survey to Truss Company prior to
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
Tooter steel.
.T 4 Co Crete Anchors Per
Me ufecturera Space
F Poured Concrete or
II concrete block wall I/4"Mae
Concrete Footing
J L (see footer schedule
for exact sizes)
I
DETAIL AT WINDOW OPENING IN Aluminum Panel
Saes per manufacturer
I
Scale: 1/2" = 1'-0° See 7uwcal Stud Detail
CBS WALL
I
I
i v SINGLE PLY REAR GIRDER TRUSS l/8" x 3/32" Wing Nut w/appropriate washer and spacing
per manuFacturer's Details
mm Beu u
Nail 2" x 4" blocking to vert. leg of I m O94
truss with IOd x 1.5 nails at 4" o.c. I _
m m
y Install Simpson MGT into wall usingg d
\ dia. threaded rod set min. 12" m
into wet beam and (22) IOd nails into trues n I e
into
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
AT CENTER BEARING POINT
'1/8" thick light textured stucco installed per
ASTM C 92L over ASTM D tgpe 2 paper backed
wire lath nailed to substrate through one lager of
ASTM D Tggpe 2 felt paper using Sd nails. Substrate
to be 19/32' COX Plywood nailed at 6" o.c. in field
and edges with lod ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Additional Precast Lintel
#5 bars
Lintel
Length
Bar
Length
Clear
Span
u
AuB
Bars
u u
Bars
I'-6"
2
i `�:!` %i i i �•
1 1 •' 1
T-10"
2'-8"
#3
none
1 I 1� 1 1 I
's.---- ---- y I`----J'
3'-4"
2'-2"
2,tt3
none
SFS-OB/IT BP8-IB/IT 8F8-IB/2T
4'-O"
3-10"
2'-8"
2,43
none
Additional
4'-4"
3'-2"
2,#3
none
.... �#5 bars.,
`
CLEAR- .^ .I:
• me Row of "H" O
'•,`:{;': Block Above
5'-2"
4'-O"
2 #3
none
5'-101,
5'-81,
4'-6"
2 44
none
r : 7 Precast Lintel r
�' Additional
-4"
5'-4"
2,#4
none
1•
#5 bars '
�'-6"
�'-O
6'-2"
2 u5
none
BFIL-IB/IT BFIL-IS/2T
�'-10"
T-O"
2,#5
none
NOTES:
ALL reinforcing steel is grade 60.
I. min. coverage of steel=1.5"
2. min. bearing required a ea. end=8"
3. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
11
LINTEL SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Caat-Crete
S ecification
Rows of
"H" Block
Above
" ,r
Bottom
Steel
S1Z°
Top
steel
S1iQ
Max.
Gravitg
Load
(PLF)
Max.
Uplift
Load
(PLF)
Max
Lateral
Load
(PLF)
L22
2'-2"
3'-4"
8F8-OB/IT
I
#5
3049
1 1569
1024
L31
2'-4"
2'-8"
3'-11.
4'-0"
8F8-OB/IT
I
#5
2541
1343
143
L45
4'-5"
V-10"
SFB-OBAT
I
#5
1105
909
339
L50
5'-O..
L'-G"
BP8-OB/IT
I
#5
1238
835
121
1-60
4'-8"
T-V
8F8-OB/IT
I
#5
1011
121
534
LBO
1 8'-0"
1 9'-4"
SF8-IB/2T
I
#5
2
#5
152
591
512
L90
9'-0"
lo'-4"
BF8-IB/2T
I
#5
2
#5
443
1 530
401
L90B
9'-0"
10'-6"
BFI4-IB/2T
ONE
1
#5
2
#5
1533
1 1183
401
LI00
10'-0"
ll'-4"
8F8-IB/2T
I
#5
2
#5
582
1 494
452
LIOOB
10'-0"
II'-4"
8FIL-IB/2T
ONE
I
tt5
2
#5
1344
1028
452
LI20
12'-0"
13'-if"
8F8-IB/2T
I
tt5
2
#5
411
428
324
L120B
12'-O"
13'-if"
SF16-6/2T
ONE
I
tt5
2
#5
1015
110
324
LHO
14'-0"
is,-v
BFIL-I15/2T
ONE
I
tt5
2
45
1250
609
259
L140
IL'-O"
1'I'-4"
8F8-IB/2T
2
#5300
192
144
LILOB
III
IT'-4"
BFI6-IB/2T
ONE
E
#5
;2
#5
950
Soo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATIOIN, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
With (10) IOd x 1 1/2" nails -
( 24" o.c.) supporting Max.
1810lbs. uplift
Aluminum Drip _
Edge t Fascia
12"
2" x C Sub-F
Kagcan full o vent vtngl soffit installed
using 1/8" dia shank x 15" long gale.
rooting nails with 3/8" dia. heed per
product approval - see chart sheet #1
12" x 12" concrete column
block filled with concrete
and (2) #"I bare vert. tied'
into lintels above
thicken edge to 8"x8"
with concrete and
one tt5 bar continuous
BEYOND
Top of Tooter
14" below finished floor
1 1=IIII=III
4
12
�—
1/2" thick stun
attached to hl
framing with me
me less than (-
horizontal wood
into vertical w
Aluminum Drip -
Edge t Fascia
Poured Concrete \
concrete block wall
Concrete Anchors F
Manufacturers Specs
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) 10d is
at each web
hi -rib lath
vertical wood
n to provide
.ration into
3/4" penetration
members
Stud Detail
Stud w/ Die Cast Zinc NTe
Nickel Plated Wing Nut
IH°
Flush Mounted Shutter Detail
nts
5/8" thick light textured
stucco on tgpical concrete
block construction _
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess. Wood
Base
Step
Slope
per
per
foundation
foundation
plan -
plan
a
1�
(III till III( till
14"
�IcaI Section
Brace Gable end
with 2" x 4" SYP #2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WC
9 24"o.c. TYPIC
( shop drawings bg manuf
R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
.and (1) #5 bar Cont. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar Cont. for bottom row over openings
1/2" drywall over 1" x furringg
strips at 14" o.c. with R4.1 frfoil
-insulation on tgpical 8" Block walls
All drywall to be installed per FBC RIO'
and shall meet all pertaining ASTM codes.
Mortar to be Type 'M" only proportioned
and Mortar joints shall comply with FBC P
Provide Our-O-Rock at all wet areas (er
Fill cell with concrete and
(1) #5 bar vert. (tgpical).
'Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
FI
at Front forc
Scale : 1/2" = 1'-0"
Strap truss to wall using Simpson MGT with
5/8" dia. threaded rod with min 12" embedment
. _ .. .. _ .. rota II altlpr IIIRt. opt er In enoxu with
Provide downspout hurricane anchor at each truss rroviae aownspouL
( 24" o.c.) suppporting Max.
1810 Ibs, uplift
in
to
3 X
93
r
OL rn
N Ql
<10 O CL
a
L
=to
s � ui
U
in O Q
E_�_
�uN
PANEL
"A"
Poles
BR
Load
Wire
Description
circ#
circ#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
#10
40 gal. water HTR
5
Range
#6
12.0 kw
50
2
l
8
1
20
1.8 kw
#12
Pump
9
10
Dr er
#10
5.0 kw
30
2
II
12
1
20
LS kw
#12
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
15
It.
Refrigerator
#12
1.2 kw
20
1
I
20
L5 kw
#12
Kitchen S.A.C.
Il
18
Recepts
#12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
-
20
1
1
20
1.2 kw
1 #12
Clothes Washer
21
22
Recepts
#12
-
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
-
20
1
1
20
L4 kw
#12
25
26
Recepts
#12
20
I
1
20
1.92 kw
#12
271
28
Recepts
412
20
1
1
15
#14
General Lighting
29
$0
Recepts
#12
20
1
-
1
15
-
#14
General Lighting
31
32
Recepts
$12
20
1
I
I5
-
414
General Lighting
33
1 34
Exterior GFCI
#12
20
1
1
IS
#14
General Lighting
35
34
Bathroom GFI
#12
20
1
I
20
412
Smoke Detectors
31
38
General Lighting
#14
IS
1
I
20
#12
Bathroom GFI
39
40
General Lighting
#14
15
I
sriare
41
42
1 spare
PANEL "A" LOAD CALCULATION SHEET
Load Description Qty. Watts Total(Watts)
General Llghting (3 watts sq. ft.)
S,maIL,A.ppliance. C,Ircwt(s). ......... ......... .............
Rang.e............ ........... ....... ......... .............
Refrigerator
Microwave.....................................................
Dish Washer
.................................................................
Clothes ...............................................
Clothes,.Dryer............. ......... ......... ..............
Water Heater
.................................................................
Water Pump ...................................................
Garage, Poor. Opener . . . ........... . ................. . . . ...
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
1.200
1,200
1
5 000
5,000
1
4,500
4,500
1
1,800
1.800
1
810
810
Total Watts 31,415
First 10000 Watts 9100% 1 10,000 10,000
Remainder 21,415 e40% 1 O 10,966
Electric Heat or A/C 10,000 8,65%
1
10,000
10,000
Calculated Load Watts 30,964
Voltage 240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical 5 mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
FB
Push Button Switch
�AA
Exhaust Fan
Duplex Outlet
Y
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
Waterproof, ground fault interrupts
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
oM
Carbon Monoxide Detector
4c:?
Flood Light
TQ
Thermostat
m
Electrical Panel
®
Central Vac
rc`:�
Electrical Meter
(9)
Smoke Detector
Ceiling fan
©
Television Jack
❑1
Telephone Jack
nc osc
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
xR
Speaker Hook -Up
I❑
Intercom
= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = Balanced Air
Electric Notes:
I. Use copper wire only, no aluminum.
2_ Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
5. ALL bath and kitchen receptacles to be GFI protected.
L. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RM1402
10. A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be fully operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
14. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
gear from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
i,,, and telephone company.
#2/0 Aluminum feed
1'/2' Conduit _�
2" PVC (
A/C disc.
150
MCB
PANEL
2" rigid service FPL Ber#a5#cont�rpe6awire r tor in slab
ELECTRICAL RISER
124 CFM
IOxlOXL
PORCH
MASTER
BEDROOM
I
12x12x10
B/A 124 CFM
ld2sl IOXIOxG
L-J
14,11 CFM 141 CFM
IOXIOxl IOXIOxl �.
I
r Ixlxlxlo
B/A
8x4x4
9 CFM
GREAT I ROO xng
a I LOSE
I
o 8x4x4
- - - 50 CFM
WASHER DRYER
I
LAUNDRY
141 CFM Bx4x4M F1
IOXIOxl
12
°
DINING I
ROOM IL CFM
-* eX4X4
I,�I
L T
r 1 2XI2X8
B/A
PANTRY
- - - - - - - -
-
I DW I °
° Ill CFM
I2xbxl
SECOND
IOXIOX6 I BEDROOM
KITCHEN 1L"
3 TON I MICROWAVE I 20X20
SEE MANUAL I NON -VENT
"J" and Energy 38" CLEAR T) rfr'/*A
I
Calculation L - - - O - OPENING i= It) i
for Unit info i
I
r- 12xl2x8
W.H. 114"
4 C 4" (0 Steel Ballard I THIRD
See detail on this sheet I
W BEDROOM _ __
22" x 54" i a / 1 100 CFM
Attic lightAccess I I = I I lox6xg
- Contractor shall use AL-CU Landing
- Contractor shall torque lugs I.A.W.
lugs. NTS
manufacturers recommendations which
shall be verified prior to construction
19. The electrical system shall be
completely and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and
shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes
shall be verified before
ordering. The contractor shall
provide circuit routings to
suit the Job conditions.
22. Furnish and install all fixtures
as called for on the plans
or as selected by others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum
of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1"
shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed
per FBC RM1502
GARAGE I I / II I I 11
r----------------- 1
I I
I I
I I
I I
I I
I I
I I
I i
I I
I 1
I i
I I
150 Amp
Panel
GOLF CART
GARAGE
I
I
I
I
I
I
I
I
c
IF
Vent thru
riflll Soffit
Install oulet
under disc.
not shown for
clarity
WP GFCI
N
O
U
Q
AiC
Wire For ,
Front Post
Light
i r
1
/ WP GFCI
I
I
I M O
I
I
MASTER
BEDROOM
I I �--
I I /
GREATI ROOM EA
LOSET
I \
I \
\ g
\ WASHER DRYER
I \
I \ LAUNDRY
DINING I \&=
\I
ROOM I ,
I �
GF
CAB \ - - - - - - S
I cl° 4GI:C1
1 I ITCIHE� _
53
,FCI VENT ®MICROJI �4
iNON-VENT
O 38' CLEAR
L M_ OPENIN \
- \ I
GFCI GFCI - 4- -
W.H. GFc \
4" (0 Steel Ballard / -
�See detail on this sheet
_ ifF
r 22" x
Attic Access.. - r'.2 2 1
L _With)Iglif - I m
-0- _
OPTIONAL PANEL /
LOCATION
GARAGE /� \\ -
/ GFCI 1
R \ \
/ tight\ 1
GFCI / to caner\ ,1
/ t`lJT{r
r----- ---r= -------1 \
Garage \
I Door I
I Opener I \
I I \
I I 1
I I
I I I
I I to garage (lights
I I
ff--I--�-
MEC�/4NIC/4L L/4YOUT
i
O= THERMOSTAT LOCATION SCALE: 1/4" = 1'- O "
/
Post Light with
Photo cell
Center Post Light
between driveways
11\ SECOND
I `1�EDROOM
1
1
THIRD
---BEDROOM
\
WP GFCI
GFCQ r
150 Amp C
GFCI Panel C
r T--_ =Jt2--------1
Garage
Door
Opener
GOLF CART
GARAGE
I GFCI
GFCI I I
I I
ELECTRICAL FL;4N
SCALE: 1/4" = 1'-0"
Attic Ventina Calculations
Total Attic Space = 2101 sq. ft.FBC 2309.1
Venting Ratio 1/150 = 18.00 sq. ft. required
Provide A Continuous Vented Soffit
*=LIFE SAFETY WARNING
Thi$',symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
SPAGING NOTE
Al L TF'USSES ARE TO BE SET
Al 2'-0: ON CENTER
XCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
STENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY. A
I
r/DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
�nnici u T mr(ZI
' Span,or less ®
30' to 60' Span
I degree:-
�f�o'�
Sprea er Bar
\�c or less
TT, g �_Appro. 2/3 tom
4— 1/2 1 /2 ___� I
Tag
j.. •. i- OpprOX.
tine 1/2 of Span
REFER TO BCSI
IO SCSI
rev
user I! creme used.
Truss must be set this way if crane used.
Ior- ay.
This is on example, truss may not match.
I Insist crane operator sets truss this way.
�s st
r ..3
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. AL I
HAIV F::DpILF=F= IVCsiI=
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
Carrying Girder
For Truss to Truss _ -
Connections see
hanger/connector Nails mur t be as
shown. Guide tabs o
Schedule in engineering Domeanijisnails.
package.
Carried Truss
EAT PLATES BY CHAMBERS
h+,7777.poru•ai. t'/1
I:
I
C RNER DETAIL
-ivc RIUWOSNOTSn. NFORGL RITY
12
4.00 F..
12 2.00
M
upset=1/4" hee1=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL VAULT
upset=1/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
TRUSSES FOR THE FIRST MODEL SHOULC) BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR THAT MODEL.
A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' IN LENGTH %� A
I 1
A Do not Stand on trusses until they are braced per BCSI & properly nailed to straps & hangers L 1
I
79
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'1
ABOVE FINISHED FLOOR
PORCH RIGHT
T5•_s-
I 1 I
imimiminimimimim
I\\\\\I`\\\`I\\\\i\\\\\I`\\\`I\\\\`I\`\i
\\\,
®I�
V
INVERTED "V" WEBS AT CENTER
W/9' B.C. PANNEI LOAD W/ (2)
4�
IsI
I'
imimimimimlm
�1
GRA
.-..lI - -- -- --
he Architect's or Architoct's repre
shop drawing approval is No
7"double check" of the control
'a contractor shall remain reap
for checking field measurement
other construction criteria. Arch aPproval covers general roof
rovlew of truss stra sh
structure fro pPrng' and lost
m gravity and uplift I.,
their rasp/e/�/�iv�e locations.
Approved Rv. / �� . /
_.. ,. oranen A.I.A. p,q- ____
. .
FABRiCAT10N AGREEMENT
TIaJe8FACANNOTeESTARMUMTtt"TrodAeRl&3nWtSalOMara U Tliskpeldasalhtlondfisp�op.,gtwnell.n»ww.wlte.nwr.al�
Th. rTh in" Wd and SPas�
whidrb 0is sole a roads M wlae aocadence with fils atw pplatrrelS
2A1 d4nanekn. h100 br* w, "M',a' bee, vied '
.A lkYeis wrNen rh000s la prMided by �aanad and b r;7haebat, Ttws
days wdiMlah aotoe delivery Is liu W P"d'P°°' tut mo E.cktlh.g,s wa bee a wssd�'r'6h tlr
to bells tepsbs req A64 orb a Othe[puanes. eY Cthvhhbas)opl6n- days In
4 The vdebn �hSd adugrledtes teeelpt d"Boo 140' air a lrysMet t' TP13 W
O"I lob sI a Is fie ft"e#'rwppyl, b mate Oe lei aft al"
delivery. C of nb s Tna ho the ad' aAhNIIII delemiwa an adab� dtmlob tl
The buysls reavorablefor d�'didan 7naa win bs hemarrappa dirnp dateay
beau"job sae b riot pspasd par ds orwhlse o Crhrr6ae TM" has b red
Buys ls tespanetbp b Charebers T y s buyer Y rwl prepaed par "My d tru
a Pace as Chown badp Calls due b aoe oorrdoma•
Ohli.te*i Asm Perk p ls+bb /ary as ma
7: TM*. k a PURCHASE oFtDER Do Chambara a aPasd br s igrssaad ■ re"aiebp pdha. kraolce sIa be made en "y amd Paid hdfib taftr c 6n career. Ineoke rpsy, be rinds d sdrodhled dap d
deMry d Mdested.eases. The underalpud amen to thaa6am"Very I ba Try m
. d 61-i addedfor rAna not p Idate'Ot am� wade' 1'1/t %psmuytr "1
• & SlPabas slhaai arryslhara m fib aheN cahhaWaas aPsarrher. b d tarrrw hareu
• 91 oaoNantlon of Chanbas Tnaa wdendlrp asrdt for of matedd do v dank
wabas Tn+s+� � mo"V ,,,,U ,e oY01"A when dw Of �ha ha and all bd0bpdrh"a was
ldabpdrusa 1*19 140"" leas, o derma In daabrhad apses b pry' r
�,t. PaYoasnt far hrr/OW be roads by
10. In eMhet refeevedrred
ed all R,, eoaebm4q fife apsanNhl, me uma Ankhed hate.
bbee 8a1it L0ap'� , P41 .Pas oat am apla w.aw bx any wdh Scum
11. D"bn easpahsmmas are per-NanorW StandardAnd Wdma handed CWdaih" f
. Mr4 r 200 ucft Uaile Melsd Plsp Ceraharled Wood Tnhlh"s
ti
DATED^•+
XONED
FOR
Multiple ply trusses must be fastened togetlher per enghwerliq
before they are set; failure to do so can re'suitin roof conapsfe,
Temporary and Psrmas wnt bracing are required and can save ff
and property and Is the rr sponsilbigtyy or the truss erector.
'Study the contents of the information packet included on defter
before setting tnus8s .
7itmees mustbesetand braeod perdeslgn b parent il�tayL danslpe,
Trusses must be a=t plumb and square
Do notUd bunks or stack of plywood, roofing material or any
_ofhei whit errbraisd loads on trusses, fhb can cause cofap"
DO-NOTSET TRUSSES USING THIS LAYOUT
uSE LAYOUT DELIVERED YYITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3106 Oleander Avenue
Fort Plerde; Floitda 3OR4423
800-551.5932
Fort Puna rr"1136"2012 Fax 7714668711
Vero Beach ' M-66g"2012 Stuart - 77Y 2S6,i302
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
—
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2014
Wind Design Method Main Wind Force Resistir
,.
Roofing Material Shingle or Shake
0
Loading in PSF Roof R.D.L.
A ,
r
a
Top Chord Live 20
°j
w
Top Chord Dead 7 4.2
j
Bottom Chord Live 10 Non -Concurrent
c c
Bottom Chord Dead 10 3
TOTAL Load 37 7.2
m
c I
Duration Factor 1.25
2
Wind Speed 165mph
Top Chord C.B. Sheeting by builder.
t m
Bottom Chord C.B. Sheeting by builder.
ci
Highest Mean Height 15"1
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2014
R.D.L. Restrains Dead Load C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer. ,
Design Criteria is the responsibility of the
Buildin Desi ner and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: Ml1392
Scale: 1 /4 =1'
W
82 total trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:-�%O> 1SI
W
Date:10/07/15 Revised:10/15/15
I I 1 1 �^ FOR
61 1 14'�' vJ WYNNE BUILDING CORP.
i' CLOUZSED AREAS ARE 0F v �� DESCRIPTION:
/ SPECIAL C AFFU & MUST BE f PORCH LEFT
71 CARLTON 3BED REAR PORC
r CHECKED CAFFULLY & MAY �
t 2 INDICATE DEVOTION FROM PAGE 1of1CUSTOMER INnWSEACH PAGE
—
15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11392 7y1
PLANS.,. i��_�--