FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ftz
b.Frame-Wood, Exterior R=11.0 187.33 ftz
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 2 d. N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1446.6o ftZ
6. Conditioned floor area(ftz) 1446 b.N/A R= ft2
7. Windows** Description Area c. A R= ft
z
a. U-Factor: Dbl,U=0.54 99.23 ftz 11.Ducts R ftz
SHGC: SHGC=0.25 a.Sup:Attic,Ret:Attic,AH:Attic 6 320
b. U-Factor: Dbl, U=0.55 40.00 ftz
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft. a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems
z a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft EF:0.97
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) yO�TKESpATAo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed k�,�'��%' r =
based on installed Code compliant features.
li
Builder Signature: Date:
Address of New Home:�'\\ S City/FL Zip:3� pD WE
���
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. Fo
information about the Florida'Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/6/2017 9:01 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
I
- wrightsoft- Project -ummally : Jo
Entire House By:
QUICK CALLS, INC.
317 ST.LUCIE LN,FT.PIERCE,FL 34946 Phone:772466 6799 Fax 772-466-6796 .Emaili QUICKCALCS°AoL.COM; .
Project Information
For: THE GRAND CARLTON
�WYNNE DEVELOPMENT, FT.`PIEERC , FL
Notes: `_k\
Design In • •
Weather. Fort Pierce, FL, US
Winter Design Conditions. Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db. 70. OF Inside db 75 °F
Design TD 28 OF Design TD- 15 OF
Daily range L
Relative humidity 50
Moisture differen
ce 61 gr/lb/b
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh Structure. 17520 Btuh
Ducts 5654 Btuh Ducts 8536' Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none .
Hu'(none).
idification 0 .Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh' Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipmenf sensible load 24753 Btuh j
Method Simplified Latent Cooling Equipme-nttoad Sizing
Construction quality Average
Fireplaces 0 Structure 3203 Btuh
Ducts 2318 Btuh
Central vent(0 cfm) 0 Btuh j
Heat ingg . Coolingg_ (none).
Area(ft2) 1446 1446 Equipment latent load 5521 Btuh
Volume(ft3) 12511 12511
Air changes/hour 0.45 0:23 Equipment total load 30274 Btuh
Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton
i
Heating.Equipment Summary Cooling:Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING
Model 25HBC536A"030 Cond 25HBC536A*030
AHRI ref 7914585 Coil FX4DN(B;F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heat
ing.input Sensible cooling 24360 Btuh _
Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 27-OF Total cooling 34800 Btuh
Actual'air.flow . 1160 cfm Actual air flow 1160 cfm
Air flow factor 0:049 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 6.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.83 li
Capacity balance point 32 OF
Backup:
Input=7 kW, Output-23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
„ wrightsoft` 2017-Apr-11 09:29:38
�CCA Right-Suits®Universal 201717.0.14 RSU08101 . Page 1
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calo=MJ8 Front Door faces: N
i
I
-wrightsoft° Right-M Worksheet Job:
Entire House Date:
QUICK CALLS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946•Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House BEDROOM
2 _F�cised wall 156.2 ft B49.0 EDROOM
ft
3 Room height 8.7 ft d 8.0 ft heat/cool
4 Room dimensions 1.0 x 297.0 ft
5 Room area 1445.5 ft2 297.0 ft2
Ty Construction LI-value Or HTM Area (ft2) Load Area
number (BtutVft2-.OF) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool. Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-0ocs :0:143 n 4.00 2 55 `509 , 465 1862 1184 72 72: 288 183.
.4A5 tom 0:770. .V, 21:56 19:31 38 0 815 Z30 0: -0 0 0
13A-4ocs 0.143 a 4.00 Z55 128 83 333 212 0 0 0 0
IA-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
19 13A-4ocs 0.143''se 4.00 Z55 .34 34 136 66 0 0 0.- U
V�/ 13A4ocs 0.143 s 4.00 Z55 360 353 1414 .899 216 216 865 550
t-G IA-c1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0
13A-4ocs .0.143 w 4.00 2.55 310 237 949 603 104 .72 %288.. 183
1.A�1om; 1.270 ..w 35:56. 55.21 32 2 1140 1770 32- 2 1140 1770
4Ar2om ... 0 770" w- 21.56 19.31` 41 :. 41;. . 880 : . 788 0 0. ;- ;0 -0
P 12C-Osw 0.091, - 2.55,: 1.28 192 192 489 246 0 0 0 0
C 16A 30md 0:032 0:90; ..2.32 , - 1446;, 1446-: 1295.,:_ 3354'...:. 297-1 297 '266 689
F 22/ktPl 0.969 27.69 0.00 1446 156 4325 0 297 49 1357 0
I -
6 c)AED excursion 918 627
Envelope loss/gain 14961 133491 4204 4003
12 a). Infiltration 2887 791 848 1 232
b) Room ventilation 0 0 0 10
13 Internal gains: Occupants @ 230 6 1380 3 690
Appliances/other 2000 0
Subtotal Qines 6 to 13) 17M 17520 5053 4925
Less extemal load 0 0 '0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17848 17520 6053 4925
15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400
Total room load 23503 -26056 6653 7325
Air required(cfm) 1160 1160 328 326"
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -
- -�- wcightsoft- 2017-Apr-11 09:29:38
Rig ht•Suite®Universal 2017 17.0.14 RSU08101 Pagel
...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
II
- wrightscife ',Right-M Worksheet yob:
Entire House Date:
'QUICK CALCS, INC. By:
317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466.6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM.
1 Room name WIC KrrCHEN
2 Exposed wall O ft O ft
3 Room height 8.0 ft heat1cool 8.0 ft heat/cool
4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft
5 Room area 54.0 ft2 172.0 ft2
Ty Construction U-value Or HTM Area -) Load Load
number (BtutVft?T), (Btu ft2) or perimeter (ft) (Btuh) orb perimfeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool
6 13A-0ocs''; :.0143 :n 4s00 2.55' 0 0 0: 0 0 '0 0 p
4AS2om. ;9,770 .°ri: 21.56 19 31 0 0 0. 0 0' '0
13A-4ocs 0.143 a 4.00 2.55 0 . 0 0 0 0 0 0 0
1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13A-46cs 0143 se. 4.00 2:55 0 0. 0', 0 0 0 : -0 " <o
III V�/ 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
I G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
Md 13A-06cs 0143 . w= 4.00 '2.55 0 0 0 0 0, 0 0 A
1A-c1gm;' 11270 w 3556 55:21 0 0 0 0 0 0 0 0
4A5 2orrr;. 0.770 w _- .21.56 19.31:` 0, 0 0 0 0 0:-. A 0
P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82
C :.'16A�Omd , 0.032. 0.90': 2.32 54,:. 54'. 48. 125:; 172 172 154 399
F 22A tpl 0.989 27.69, 0.00 54 0 0 0 172. 0 0 0
6 c)AED excursion -9 -170
Envelope loss/gain 48 117 317 311
12 a) Infiltiation 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 !2000
Subtotal(lines 6 to 13) 48 117 317 . 12311
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 48 117 317 2311
15 Duct loads 32% 496% 15 57 32% 49% 100 1126
Total room load 64 174 418 3437
Air required(cfm) 3 8 21 153
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
A Fk'_wrrightsott-, Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N g
1
- -wrightsoft. Right4@ Worksheet Job:
Date:
Entire House
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS a1AOL.COM
1 Room name BATH BEDROOM 2
2 Exposed wall 5.0 ft 34.2 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft
5 Room area 45.0 ft2 203.5 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (f?) Load
number (Btuh/ft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool
6 V�/ 13A�oosj ="0143 ,.n 'W Z55. 40 40 160 102 128 - 128 513 ;326
G.r4f2om 0.770 n 2156-. ::19:31. 0 0 0 0 0 ;0 . . :0 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143
1Aclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
1 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
dN ':13A-iocs 0.143 se• 4.00 Z55 0 0 0 0 34 34 136 '86
13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
t-G 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A-0acs 0143 w 4;00 2.55 0 0. 0 0 0 0 0 0
1A clom :1 270 _w: 35.56 55.21 . p :: 0 0,. 0 0" 0 0 0.
4A5-2om 0 770 W. 21;56 . 19 31 0 0 ::• Q 0 0;. 0._ :0 . 0.
P 12C-0sw- 0.091 - 2.55 1.28. 0 0 0 0 0 0 0 0
C . 16.AOmd D.032 -;0:90 2.32 . 45. - q5 40_ 104-,.. :'204 2pq• 1t32 472
F 22A tpI 0.989 27.69 0.00 45 5 138 0 204 34 946 0
%:
b.
6 c)AED excursion -16 -85
Envelope loss/gain 339 190 2978 3106
12 a) Infiltration . 87 24 593 162
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 p
Subtotal(lines 6 to 13) 425 214 3571 1 3498
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 425 214 3571 3498
15 Duct loads 32% 49% 135 104 32% 49% 1131 1704
Total room load 560 318 4702 5203
Air required(cfm) 1 28 14 232 232
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-F[4- 2017-Apr-11 09:29:38
Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 3
...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
� I
'wrightsoft Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.cOM
1 Room name LAUNDRY GREAT/DINING
3 Room ed )height 8.0 ft 6.0 ft heat/cool 9.8 ft 47.0 ft heat/cool
4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft
5 Room area 42.0 ft2 526.0 ft2
Ty .Construction U-value, Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-`F) (Btuh/ftz) or perimeter (ft) (Btuh): or perimeter (ft) (Btuh
Heat Cool Gross N/P/S Heat Cool Gross N/P/S. Heat- Cool
6 y! 13A4or : 0143 n` 400 255 0 0 0 : 0';' 255;r 2'1:7 869 552
0.7Z0.-ri 2156, - 1931.. . 0 0 , 0 0:.. 38' 0.. 815 "•730.
13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 .0 0 0
1A-c1om 1.270 a 35,56 87.29 0 0 0 0 0 0 0 0
11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W, .13A-4ocs 6,143 'se - 4.00 . 255 0 0 0 0 0 0 ' :_0 0
VI/ 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0
L-G 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A4ocs .0143 w 4.00 2.55 0 0 0 0 .206 165 661 420
,1Ac1om ': . . 1270 .w 3556 55.21 0 0 0. :0 0: :0 0 0
4A5 2om:;. -.0 776 w 21.56 19.31 0 0 A. 0 41 41 ., 788
P 12C-0sw 0 091 -_ 2.65 1.28 56. 56 143- 72 0 0 0 0
C 16A-30md ,: "0 032 - 0.90 2.32 42:,. . ,..'42 38 :_ 97 .:.. -526::..... 526 471 1.220
F 22A tpl_ 0.9.89 - 27.69 0.00 42 6 166 0 526 47 9302 0
6 c)AED erxursion -22 668
Envelope loss/gain 539 270 4997 4379
12 a) Infiltration 104 28 997 273
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 2 460
Appliances/other 0 0
Subtotal(lines 6 to 13) 643 298 5994. 15112
Less erdemal'load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 643 298 5994 15112
1151 Duct loads 32% 49% 204 145 32%1 490/c1 1899 2490
Total room load 846 443 7892 7602
Air required(cfm) 42 20 390 338
Calculations approved bvACCA to meet all requirements of Manual J.8th Ed.
~A - - wrigF�tsoft' Right-Sulte®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4
...uick Calcs\DocumentslTHE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
- +wrightsbW Right-M Worksheet Job:
Entire House Date:
• QUICK CALCS, INC. By.
I317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772.46"M Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name FOYER M.BATH
2 E)posed wall 7.0 ft 8.0 ft
3 Room height. 8.0 ft heaticool 8.0 ft heat/cool
4 . Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft
5 Room area 50.0 ft2 56.0 ft2
Ty .Construction U-value Or HTM Area (ft2) (ft2) Load
number (Btuh/ft2-°F) (BtuWft2) or. perimeter (ft) (Btuh) oorperimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A�tocs ?0143 ,n.. 4.pp 2 8 8 32 20 >: 0. 0
;0 770 .6.n 21;56 19.31 < p p 0 0: 0:.: 0.
13A-4ocs 0.143 ' e 4.00 2.55 48 27 108 69 0 0 0 0
-G 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 r-D_ 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W- . A3A46cs 0.143 se 14.00 2.55 0 0 0 0 0 0 0 0
V►! 13A-4ocs 0.143 s 4.00 255 0 0 0 0 64 57 228 145
t-G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241
13A�ocs. 0143 w 4.00 2.55 0 . 0 0 0 0 0 0 0
1Ao1om 1.270 w- 35.56 65:21 -0 0 0 0 0` 0 0 0
4A5 2om'_. 0.770, w. 21;56. .1931 0 0. 0 0. . 0 0. 0 :;0.
P, 12C-0sw 0.091. - 2.55 1.28 .72 72 183 92 0 0 0 0
G.. . ..:16A-30md::.. 0 032 • - 0;90 . 2;32 50 50 45 116, . 56: 56 50 130
F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0
6 c)AED wcursion -39 -38
Envelope loss/gain 792 496 747 478
12 a) Infiltration 121 33 138 38
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other- 0 1 0
Subtotal(lines 6 to 13) 913 529 885 516
Less exiemal load 0 0 0 0
Less transfer 0. 0 0 0
Redistribution 0 0 0 0
14 Subtotal 913 529 885 516
151 Duct loads 32% 49%1 289 258 32% 49% 280 251
Total room.load 1202 787 1166 768
Air required(cfm) 59 35 58 34
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
A- wcightsOft' Right-Suite®Universal 2017 17.0.14 RSUG8101 2017-Apr-11 0 Page 5
uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=We Front Door faces: N 9
I
� I
wri htsoft eruct System Summary job:
9 Date:
Entire House By:
QUICK CALCS,INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
Project
• ' • •
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Heating. Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0,in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250' in H2O
Lowest friction rate 0.285 in/100Ft 0.285 in/100ft
Actual air flow 1160 cfm 1160 cfm
Total effective lehgth.(TEL) 176 ft
SupplyDetail Table
Design Htg Clg Design . Diam H x W Duct: Actual Ftg.Egv
Name (Btuh) (cfm) (Cfm) FR (in) (in) Mat Ln (ft) Ln(ft) Trunk
BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4_ 115.0 st1
BEDROOM 2 h 4702 232 232 0:360 7.0 OxO VIFx 23.9 115.0 st1
BEDROOM-A- h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2
BEDROOM-B h 3327 164 163 0.285 6.6 6x0 VIFx 40.6 135.0 st2
FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0
GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2
GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO -VIFx 31.8 135.0 st2
KITCHEN c 3437 21 153 0.379 .6.0 OxO VIFx 17.0 115.0 st1
LAUNDRY 'h 846 42 20 0.361 4.0 Ox0 VIFx' 23.3 115.0 st1
M.BATH-A h - 768 58 34 - 0 0 OxO VIFx 0 0
WIC C 174 3 8 1 0.309 4.0 Ox 0 1 VIFx 1 27.0 1 135.0 st2
i
i
Supply Trunk Detail . • -
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk
st2 Peak AVF 721 672- 0.285 918 12.0 0 x 0 VinlFlx st1
SO Peak AVF 1043 1691 0:285: 1020 14.0 0 x 0 VinlHx
-ram} Wrl htsoft` 2017-Apr-11 09.29:38
1� 9 Right-Suite®Universal 2017 17.0.14 RSU08101...uick CalcslDocumenWTHE GRAND CARLTON4446.rup Cale=MJ8 Front Door faces: N Page 1
i
I
i
Return Branch Detail Table
i
Grille Htg !. Clg . TEL Design Veloc Diam H x W StucUdist Duct
Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in), Matl Trunk
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx
II
I :
I
i
i
j
2017-Apr-11 09:29:38
.` "� wrightsoft° .Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
ti
•..uick CalcslDocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Doorfaces: N
i
I