Loading...
HomeMy WebLinkAboutRevisions; Truss Package Update�r- d5 OFFICE USE ONLY: DATE FILED: REVISION FEE: LOCATION/SITE ADDRESS: 3209 Trinity Cir PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 j (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION Creekside Plat # 4, Lot 68-- Permit # 2002-0099 DETAILED DESCRIPTION OF PROJECT REVISIONS: Original signed and sealed Truss package for change of Truss company. Permits were from 2017 building code, attached documents reflect 2017 building code CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC1327068 BUSINESS NAME: D R Horton Inc QUALIFIERS NAME: Brian w Davidson ADDRESS: 1430 Culver Dr NE, CITY: Palm Bay STATE: FL PHONE (DAYTIME): 321-953-3162 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 STATE: ST. LUCIE CO CERT. #: FAX: ivw.'w rAA: ZIP: 32907 ZIP: ZIP: Planning & Development Sendces Building & Code regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982. REVIEW COMMENTS PROPERTY INFORMATION Address: 3209 Trinity Cir Owner(s): D R Horton Inc City / State / Zip: Fort Pierce, FI 34945 Parcel #: 2327-502-0076-000/4 Jurisdiction: SAINT LUCIE COUNTY Zoning: PUD Lot#: 68 Block: APPLICATION INFORMATION Permit Number: 2002-0099 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Brian W Davidson Business Name: D R Horton Inc Business Addr: 1430 Culver Dr Ne City / State I Zip: Palm Bay, FI 32907 REVIEWS AND COMMENTS Review Type Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lori Bender Comment: DOCUMENTS MISSING APPROVED Audrey Humphrey Comment: ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey Comment: NOTIFIED FOR PICK UP COMPLETE Ellen Vaughn Comment: PE REVIEW COMMENTS (2) COMPLETE William Durden Comment: PLANS EXAMINER REVIEW COMPLETE William Durden Comment: REVISIONS INCOMPLETE William Durden 3/9/2021 Comment: CHANGE TO TRUSS MANUFACTURES. 1 Automatic Sprinkler System? No Fax Number: Email: Melbournepermitting@Drhor ton.Com; Bssmith@Drhorton.Com Date Started Date Completed Date Released 2/19/2020 2/20/2020 2/20/2020 2l5/2020 12/14/2020 12/14/2020 2/11/2020 2/12/2020 2/12/2020 2/5/2020 2/5/2020 215/2020 11 /20/2020 11/20/2020 11 /20/2020 5/22/2020 11 /20/2020 11 /20/2020 2/27/2020 5/22/2020 5/22/2020 3/9/2021 jV COP,, Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 REVIEW COMMENTS 2 3/9/2021 Comment: ENGINEERING PACKAGE DATED SEALS ARE NOT CURRENT. PLEASE SUBMIT CURRENT DATED DOCUMENTS. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: ENGINEERING PACKAGE CODE / MISC CRITERIA IS INCORRECT. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. Comment: SUBMITTED DOCUMENTS ARE COPIES. DOCUMENTS THAT REQUIRE A SEAL AND SIGNATURE MUST BE 3/9/2021 SUMMITTED IN ITS ORIGINAL FORM WITH ORIGINAL SIGNATURES. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: MANUFACTURERS TRUSS DRAWINGS DESIGNER DATE NEEDS TO BE UPDATED. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. 3/9/2021 Comment: MANUFACTURERS TRUSS DRAWINGS DESIGN CRITERIA IS INCORRECT. SEE SECTION 107 OF THE 2020 FLORIDA BUILDING CODE. ZONING REVIEW COMPLETE Lydia Galbraith 2/18/2020 2/18/2020 2/18/2020 Comment: 7,. 0 I N a co I I — 0 I N REFER TO EN L PAIX FOR CONNECTION. .I PLUM TYPICAL 7AL—�`' SETBACK CORNERSET LABELING AND SPACING SHINGLE ROOF lid 21'-4" 4'-4- 16 14'-0' F,�� 39'-8' !�' Labeled End Mark NOTE DO NOT CUT OR ALTER TRUSSES WITHOUT CONSENT OF THIS OFFlCE BACK CHARGES Total Truss Quantity = 72 DEPAR"OT BE TMMENT AACCEPTED CARP�QrtERR CONTRACTORS ORSSROFAAMEERRIICA,IINC. 8777-29 E9C7 THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. General Notes 1) bum= fat Irmo ow flat 9ideo bare tln top w PoAiely P*w van 2)::&ff" mbWemq nw=MAW 0110 e 3) N Tam opzN is 2r O.C. miy di rpis sated. 4) Per T. Ptle k.% BOS-BI rernron.detim Per a x-0.o6g atledd be piomd a M mmimn aporiiy 15' O.0 apoa O.e we% m �dm ' bel.oet aodl flame refer m B ' for oy od60o.w bra* deARL ROOF LOADING SCHEDULE TCDL = 70 PSF BCLL = • PSF BCDL = 10 PSF TOTAL = 37 PSF DURATION = 1.25 R WIND SPD/TYPF 160 ENCLOSED BLDG EXPOSURE = C USAGE = RESIDENTIAL CAT II WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 pSF DESIGN CRIfiERIA FBC 2020 TPI 2014 Tmm member desp� & wmectorpL•Mes are de ,p�MreAd for ASCE 7-16 and —amm foran'dt.-."dw%pooemsaadcladdfMgs and maiMwiMdferoe redstiog ry'�ems • Tb,,,— havebeen revirnxd w wry• an addmo.I 10#ps'm mbonom chmdlive FLOOR LOADING SCHEDUL TCLL = PSF TCDL = PSF BCDL = PSF TOTAL = PSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS AND UPLFTS ARE SHORN ON ENGINEERING WALL KEY O B'-8• s • � �s 0 CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE Q N. W. WINTER HAVEN FLORIDA 33880 PHONE.CBOW 959-8806 Fax. (e63) 294-2488 BUILDER D.R. HORTON STATEWIDE PROJECT CREEESIDE MODEL 1828/CALi/4EBB CCA PROJ/MODEL/ALT 7A5/ 182EC E/ 02 ALT DESC OTC OPT. Lo IR ./ tC ■ v COV. Lmm LOT 88 BLOCK DESIGNER PAGE RFS 1 3 TE 330 17 L'# 334501E 1 4 "=1 �r �- ENGINEERING PACKAGE C�6 Builder: DR HORTON /STATEWIDE _ b Project: [7A5�/3i�OC�REi�iSI�D� Model/Building: 182EC,E Lot Alt:�--- Lot: E8-----�-� Address: Block: CARPENTER CONTRACTORS OF AMERICA, INC 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 Unit: t 0 10 W6 t ALPINE March 1-3,20.19 Mr. 'Bob. MW61haalls, C.arO&ht6rZo.ntr6ct6r"s of Arn&riba, Ina:. -3900 Avenue G, Northwest. Winter Haveh,.-FL .33880-6201 Re: AlternatiV6 lh�tillationafor 4 single 019 carried truss with a width less than the .' hanger .,width,A.and Wood..bIorkingIQ:achieve fdll deslgo loadvalU6 for face- duhtedhangeratta6hnW,6n.aone ply - Supporting girder (Reference Mail WA3M2).`. Dear Bob, For "a single ply carried truss with a. width 108than'the hanger width -you'. '.. . can install gqll..a.prefabricated . jack' scab .truss (I for wQQd.fIllerbj6ckihgIThe chordsizes; -chord and Alpine bhhector.plate(s) to. be -the. same as the si6gle:ply'.carded truss. The prefabricated .jack :'.'scab 'truss ry,W.ilI li.4v6 a..minimu m_ length of 4Tand Will have a. minimum pitch .2 The single ply carried truss shall have..a reaction of 3, . .500,4 or le0s. Attach DrefEibricot6d.jack :tcab:tr.uss. wi . th. two. (2)rows� of 0.1 28"x3ff Gun C ." . in . Nails at O.C. stagger 6 d 1"{See 'Fl&tb I bdlbW). P16as6 -.f6f& to.the Sihipson ro ng-Tie,C.ata)o 9 C-C 201:9- - pqgP'?I 6. for more information:., Figure I Fora s'irl g1lep 1'y*'-'* ifde'* rthat requires wood blocking to, adhi0yeJUll desigri load valueforface-mounted hangers -attach one wood- block(*) to "the baqk face of s'i*ngle::pl' . ..... y girderwith the, same size and grade. as the bottom.- 6.hbtd.. Of the singlia. -ply girder. The: wood block length to.- be such that Ahe':wood blockihg- -extends to each adja'dent"pahol pQihts;(W6bs'--ah'd bott�6michord intersectionsI-A . ft . a h wood block rows. of 0.-1 -28', X3.01i dun Nails at- 01. 0.. perrow. staggered: 3.0 applied to the .1. 6766For.um Drive Suite 505., brin.d.o.- FL. 328.2-! -www.al*Pi'neitw.com � r ~ ALPINE single. ply -girder f�ce� with an ad.ditio-na.l.(.29) 0J.2.8,!x3,W'(3un Nails jqt..each- pan el point appjied to 'the, iri ,_g- -.-^ 'd,._ . _ -_-- '--...--_- ' _ --... ...... .... ... -____-___....... ... ..... _-___... ... _`---__-_____- ___-___'--_--__-'-____-____-----'_----_-'-_-' - T-he ----of '�--------'-ckscabttudwformood ------`±fvood '-' ---g tip, r-`-'� fUU design k»adva(kuaforhangers nust by the. - _d ~'-andbhd .eind .,' naU . must. be -��td ._'','-_=of If|can.beCfany further assistance,.or if yooheve anyquestionsi please7give -me o ' Orlando, FL �_72FML � Y90.`1.Am6y ^ � STATE OF �� 6750PorUnrOdve {�1abd6,. F432821- �9790-(863}422-8885 z6rh lil ALPINE AN"C(W-PANY April 26zI.:201W Mr. Bob MIC66611S Ca.rpehter Coritradtors -of.America, Inc. 390.0 Avenue G: Northwest Wint& HW6n, FL 33880-6201 Dear. Bob,. .R6'- Str6noba'ck bridging; on roof. 'of trusses. I understand -there is §oi-h6. concern -over our recommendations f6r.'strdhdback bridging on lo of trusses, '8frongbApk bridging for roof trusses is not.a requireMent of A.N.Sl=TPI 2-QI 4 nor Is it a req uirement:ofthe Building Component -Safety, information - .(BCS.). But strongback. bridging OrY roof-- :trusses is recomr6en-clied by Carpenter,_ Cdhtrabtdrs of. Ambfica:,.-Str6hgb40k, bfldOihg se rivie-s'' the:. following. two... functions:' - One, bridging aligns the bottom chords after-fhpy: pre- set -sa t.biev are uniform. along the teilibg line: Eind.hb Two; bridging reduces rielaitive" deiflecti6fi of. adjacent: tfUss6s:, Str7ongback bridg'in g.doe's. h'ot;pr6 ; Vent or reduce -overall indi'Vidual deflection, especially any r66f"VU69691 . dpflog(in ... ........ . ... .... ....... ............. . . ..... . .. .. ....... ........ ... _g_Mqu! than I��I"c.. an Sirongopck- bridging in roof. trusses does not serve as. I ry empora. o e permanent bracing . and is not irtend6d td.distributO or share design loads. b:etoeen irUts.e..s. Con.sequeIn.tly, no design load$ have' been accounted for With this detail and continuous strohgback'Mcigirig should; not :be :attachedbetweencommon. and girde.r trusses-. The. use Hof strongbacK . bridging` shall not. interfere w . ith other, d . e sjgn considerations as, specified the Engiheb.rbf Record or the BUilding: Designer. The outer ends ofthestroqgback, bridging shall be attoched.-Io a wall 11 or anothorzecure end._restraint; t, or as sppciffed:.by the e 56 ihe' g t of R66ofd orthd Building .Designer. Str6figback- bridging" shall. be a. minimum of 2j(6 horbihbf lUm.,ibet. oriented ihiith, th-0 depth. Vertical- Attach with each ) led PqMrPQn nails 0.1'621�x&5") pails at:. intersecting rhernbet. When -extending the- strdngbatk to bridging overlap by At'a .minimum of two frostes. The,.Joca iq . of.. strong6ack: bridging.,: - maybespecified. .by the Truss Mdnifjfiaaurer,. Ehgihe&r, of , R66ord,_ or Building De§idrlet., -Please B C-81 "StrangbAdking'Provisions" or to fidpin6.: MOROPI.04 debail for more information. The. grpipbidl shown (Figure_ 1) is:for generic :illustrative purpose only. P F: o 22 Forum Drjve:9uit6 305, OflMdo, FL 32821- (80Q)-521:-979Q--.(863) 4 -8685 Ll ALPINE IN NA.. U L_ i* f-% -L L. v . I Figured. If Vcain. bb of any further assistance' or -if you have any questions; ple.ape..'give..me a c.all.. No-70861 I STATE 0 Chief gpgkippev --ZORl Alphe an I-TW'Company o�" �Pi: **4 j'.-! Engineering Depai meet t Deldn.daV FL. 82821. 6760 - Forum Drive Suite'.305, Orlando; FL 22821' (800�. 521-9.790- - (863)422-�8685 www.b1pirijai .coa . i w 0 s S.TRONGBACK, .BRIDGING RECOMMENDATIONS o-All scab --on blocks thall:.be. (x .Minimum. 1&4 BRIDGING TOGETHER 'stress graded lumber;' so-All..-stngngback bridging .and bracing -shalt .be::a. minlrnum 2x6 'stressgrocie:d:IuHbel^:" 4' ►'.The pur ose, of strop 'back brld Iha,1 to' p. 9 9 "0-" ATTACH SCAB WITH'10d:BOVGUN.. develop load sharing between ladlvldual trusses,: :41 '_V 4i6. c0.128'x3A'> NAILS']N:2 RDLIS`AT D.C. re UtIno In -an-oVdrall .Ih&&6.se' In, -the ,SCAB' .64 NDTEr :IN LIEUA3F: SPLICING, AS' SHOWN, i Stlffne5s O 'the: f IOOr. S.yS tel+1 2XG LAP."STRDNGBACK-BRIBGING NEHBERS } FOR. AT' LEAST DNE .7RUSS:,SPACING r s'ti^on. back brld In dkItIoned• ,as ,Mown In 9 : 9 9% •P STRONGBACK ' BRIDGING' ;SPLICE DETAIL. details, .1srec:ommencled .at 10' =0' .o.c. (max;> Jw--The terms: 'bridging' and 'bracing' :are sorletimes NOTES Details J. and 2. are 'the ;gYtef.erred' attachrlee t Methods ATTACH STRDNGBACK TD wEs:ui cai 1ad:cDNMoN mistakenly 'used' Inter Changeably 'Bracing' Is, nn C0.148 x3') , .NAIL $ 'DR O Im octant structural r.e ulrernent bf :4n floor p. q,• .. Y c01M EOxlGUN O. a8 xU').. NAILS or. roo.f :sgs.tem. Refer to' the Truss. D'e51gn -Dr.q; Ing (TDD). for the; .,bracing re.quirerients -for each lndlvldu:M ,truss component, 'Bridging f o particularly 'strongba6k.' :bridging' .Is' ;a: ° recothrlendcttlon' for a truss system to. help a' contr..ol .vlbratloh. In: addition= to :aidlrtig.. In the: distrlbutlon of point' loads between adjacent truss, •strongback bridging. serves' to reduce ^- ° wi USpSTRDNGBACK 8R]DGING. 0 REMENTS , 'to IW None' re ulred , pounce. or r. eslauca vlgrq lion'. `i?Esurcing, from Mgving point loads; !such as footsteps-. W. ia•20 ra:(d carkr of hod caMMON.<o;14e!x3:o') art �,,.�, a �:"� VGUN (0128'x3A')'NAILS `AT 24. OUNIMUM STRCNGBACK,.'. to. 01*19 TnP•-AND.-.BElTtOK:nF 2x RESTRAINED.AT' EAnWEND. ` r10. faserl7aipdrh� The performance of nil floor �ysterls •are enhanced 'lay. the. Insiallat(oh of :strongback- bridging and •therefore :Is. s'trongty recommended 30d OR' AN DWMM %W 11723 Rlviipart Odva SWl@ 200 r. Malylaad HelpMs.MO6304p A - _ by Alpine, For additlon4l ,infdpma'tion regardiitig. str.ongbagk 3.` bridging, refer -t ;3CS1 Guilding Component ' Safety' Information). ° e I ATTACH STRDNGBACK -M BDTTO4 OM -WI W3 1O AID -.. t�iNdmtHiily7j \\1Nj 4CK $RIDGING ATTACNMENI ALTERNATIVES •.- • rN+r.. flllaaSH T4S:L�AY1NCTh A1L calrwl�ols DCIUL�( TE alshll.tM !•.• :• LL: PSF' REF •STRDNGBACK .. . rrs rwq,i t; ex*,ir Csre.N'fow-lc4*p, hiandlhp. h:taUyf�� onhl'bnee� ldifrr #o:Ord the latest etlltbn of 3LC51 OWdeq CaAporwn! Safet xnatbn. by T'1 ond.>:PCa for saietyf .s pkw- top rrfr�p.lMsr-fiiktkxs. L-atafters OcV t i .- .1 ; No. 7086'1. TG' M. ;PSF DATE 4U%01/,14 .. shall 1»r NISL ratty otMrdre, top lord shall hour properly dttadwrd xbvctr ahwo. "baiton:� rw p property atkched rtdd erliri Leeotbv::staen foie grrosrtn}:Iaterol:resiroht of'weld y,l - - . I s C xDL PSF DRWG STRBRI$R1U14: - IVbrnryq k.wul4d per, XSI'Sect 6v 9.3 ai' ar 310 of appllf,0ar. plates. t°; to h4act. rs and pe la tbn or ibom.abave end an the' JoKt Drtols, lil_ ell rated o rsbi.. . .• �. ?SF ta_dra .160! Z.for:stv,*rd & posWorim, - � QQrrpp�� par, .fon�;y tid".dMkbn'eFdTVtoriVarPtii -' ine. Lhau'nottie'res HoA�F.�6rnefedal o, i°'6rid. thw tneerin emforrw.ee,:l/lf war77P17. or forhel�alha. ,sh4pFq: 'd.t : .� ��:TA � F�:.•: .: •. ,'ALL- ... .1." D.PSF ... . d' aA.i. Nr :MNip ar •rovsr pope . aft iris droweO. YbcotM aaceptsnar of praessteriel ' safety far .tM efmn; -Tr ww use ef: *h * r` ' a` n `er '"a � •. �/ r • �i O r. +I(. • • FAC 1.00 . .perWrlb .r x A+w++r: Per . ,Iklri+a'dkalpner per N�YLPLS�seeE: sW Ilp ifearp i�• � ..yrb� ••ea:ii ' , �'S . .. . ALPDD ..rye >w�. TPit tin3pku' t4ry SDCNI'n�.as ustry,o'oii s�i.ime PACING: • � yI'Nlrihrilnn .It n . 'IF' PALLETS'OP -_a4N OU V dmf .0-161644 WFUHING MORE -`t000 - ZR. f TnPS�t§. SHOSINa tjAN O'BE PLAOEU 4 T - T, 4C C ON MX7t'-:R'XAL.- W[ NTRATE9 , 0 A-* 16 Mug L 0 ov Pl &NP -2,4, "LEA -Tr ROT. J5 I SZt -AJPPRQPRTA %R: AVP Mt �tA i L.0 BER LAM'S AND.: DA.-T-A -Q.THEfl N.Q 't-d IvE -M r :NOT 'No RAI- IAL -ANQ 90, M,116TALL. ld D.Tv. T-1,1H ovf;,.. x IS -W U Altff 'S PY Y-W - 6 :RA&T-01R. A i 2's 41k-Oac. Monk igg go'gir/ , p VT: S UFLGO 6810 . ... ... .... .. ... U. SSEI I.S. Ff U.-Tv"m PO 8T:S- SCALE. ri E.: •- - p 17 'Elm Hel 3007-4 c P. M., UP, f. to r Cracked or Broken Member Repair Detall Load Duration = 0% This drawing specifies repairs for a truss with broken chard Member forces may be Increased for Duration of Load or web member. This design Is valid onlyy for single ply trusses with 2x4 or 2x6 broken members, No more than one break per chord panel and no more than two breaks per truss are allowed, Contact the truss manufacturer for any repairs that do not comply with this detall. (B) = Damnged area, 12' max length of damaged section (L) = Mlnlmum malting distance on each side of damaged area CB) (S) = Two 2x4 or two 2x6 side members, same size, grade, and j species as damaged member, Applyy one scab per face, Minimum side member length(s) = (2)(L) + (B) Scab member length (S) must be within the broken panel, Nail Into 2x4 members using two (2) rows at 4' o.c., rows staggered, Nall Into 2x6 members using three (3) rows at 4' o.c., rows staggered. Nail using 10d box or gun malls (0,12814', men) Into each side member. The maximum permitted lumber grade for -use with this detail Is limited to Vlsuol grade 41 'and MSR grade 1650f. This . repair detail may be used for broken connector plate at mid -panel splices. This repair detail mayy not be used for damaged chord or web sections occurring within the connector plate area. Broken chord may not support any tie-in loads, S. L L a �Typicat + 0 + 0 + 0' + 0 O + O + O + O + Str agger + = Back Face 10d Box (0.128' x 3', min) Nallsl o = Front Face 2x4 Member, - Double Raw Staggered 2x6 Member - Triple Row Staggered r Maximum Member Axial Force . Memher� Size L SPF-C HF DF-L SYP Web Only ' 2x4 12' 6204 635# 730# 8000 Web Only 2x4 18' 975# 1055# 1295# 1415# Web or Chord 2x4 r 24 975# 1055# 1495# 1745# Web or Cord 2x6 1465# 15B5# 2245# 2620# Web or Chord 2x4 30r 1910# 1960# 2315# 2555# Web or Chord 2x6 2230# 2365# 3125# 3575# Web or Chord 2x4 36, 2470# 2530# 2930# 3210# Web or Chord 2x6 3535# 3635# 4295# 4745# Web or Chord 2x4 42 2975# 3045# 3505# 3835# Web or Chord 2x6 4395# 4500# 5225# 5725# Web or Chord 2x4 TSS 3460# 3540# 4070# 4445# Web or Cj ord 2x6 5165# 1 5280# 6095# 6660# Nail Spacing Detail MWARWNWcs READ AND f'OLI.W ALL NOTES ON THIS DRAVMQI W]WORTANTww rMSH THIS DRAVDA TO ALL CONTRACTORS INCLUDING THE INSTALLERS. muses rlallb•t ewtrrnt Cart h fabACMIna. handlhp, shlpo'rw. Ins/a10a and bradna. Refer to jAt�PONIF_ AN rrW 0DMPANY tSaeeLskafronladw Itar any Ea.lh ORy, MO 63045 tie60 fact ITV IURdIn Conpentnts Oroup Inc, shaU not be esralble forarry devlaVcn f rr to bW1 *� t truss 6+ con/prnancr with ANSIMI 1, r for i,■ndi�q, ahIPDNq, N irusses. np 7 COVar po Matte INs dra■txg, ldates acceptance of pre wEaland Ky solely for 1 desgn riarti Ths mAtabllty and USE of iNs Jdrawkv the r"ponsUtty of the ➢JL*4 Dssgner per ANSUTPI I Sect. I lefarnoikn set this Job'r penerM notts page _afld ihtst_web sltts._ i yJNnun D L L Dletanee Hlnlnun L DFsfnnee 8 L ACING L ear REF MEMBER REPAIR DATE 10/01/14 DRWG REPCHRD1014 24,0' MAX �S I 11- RIDGE BOARD (2xi) % Hdlgfiv- 01 Valley C Material COLLAR SEAWFVERY MRA FAIR -OF RAFTERS o ' r comm-on-gatip. p-,6ff'.Nca` eldife-bri ajumUerqfrnols are t�t,7: -hig& tirawinsawy pplies alioys wb.-tho: 1'n'a�li.bf@;Wng under i -Max[MuM MOA 'of�f height, 30-feet .. n 0)imon Wire. -12X 80 , p ...�AMqx ubfA$CE-7-1GX- . MP ... .�Tm- Sf Tlw4s- R VALLEY -FRAMING VALLEY RAFTER.OR RIDGE 1poleb-.41-Mlldr•.36 psf trij artd -26 pslf (.TDJ Wk. zwt(ia,cFiop,R�.:fgt eaph rows', m-66;itl n Kki Iremenf-kates . 16. ui ia.ilao i.-ur- mqiii,- 4 de,diradtly &TOPlildmie. 4-WIG&i)ls 3 cilpolo.tcfafio. '416due,nalli ch nsftaathlng 4. RiftiW 41dipbeoFfilbMilt. slgdtoe-nalfs MftdYt&.two-2x6 sleoeu;-* 4 2 Od t6e;aafri 4Y.6d td&AaIIA 3104 td6.(Iju$..e2.ch slaeper-A truss 6. ::pAdge:bohr4-;a-fpof bldck 4 16d toe-nliUs 'RF9DA0Rvrm!i .7. -Alidje-bo , SM iojr.Os- 4:Wd-t6p:ii4JJls 'Tr wtodt* 'AREUSED) .13. :c411irWafn tb-Talt& 4 l6dlot-naltS. NAILA aloWl bwWA*MP.WA AWMMI .30 40 54 Zt, nWMf rr= WAIdDIC M, MAMM.,fel N-6.70801 DL 1.0 ZO 7 DAM 101plY14 fbdow Ahjr oNPXwAl'- ;.rgty y Irl;!wd, S:pw, for_- an * * . !;W , ki i :kQ;Ptr.. t 0 -'top *-e�A*41VTAvi k."k�V0%r d NZ417=14, yid ovI&M DRW.G V, PW180101S prneticei,.prior. to �Jlc YL .0 ri 0 'tA ISTATE: OF 14 0 .0 a 0 ,d U.-i U, w L h *6 2. pos mONE &-;o. we- sh.0 rop-obta. ew de T6T. 60 47 61. M TtWCO 11 cwor, . h—. ,m Am. ". -L or for' tee OR% w hforhs*c* ir jws Figap m P, b il .. .. ... Construction Connectors ki Face -Mount Hangers - I -Joists, Glulam and SCL tS 6' These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. a"r 0 Carded j `� Dimensions Fasteners , Memberin. ) Allowable Loads Acfua! .., Joist :Model Code „Min / DF/SP `= SPF/Ii Sae - No a� Web' "? Max Species Header Species Header Ref.' {tn) y E5 Stiff Regd. W H B: Face Jast Uplift Floor - Snow. , Roof, y Floor � € Snow Roof (160) {.1Q0) (115) (125)1 (100)_ 1 (115) (125) j IUS2.56/16 - 2% 16 2 Min. (14) 0.148 x 3 - 70 1,660 1,805 1,805 1,425 1,555 1,555 Max. (16) 0.148 x 3 - 7( l unr 1,&.05 1,805 v 1,805 ; y„ :,5ES rrr 1,555 1 1,555 21/z x 16 MIU2.56/16 - 29A6 157AG 21/z - (24) 0.162 x 31/2 (2) 0.148 x 11h 230 3,455 3,920 4,045 2,970 3,370 3,480 U314 ✓ 29/16 101h 2 - (16) 0.162 x 31/z" (6) 0.148 x 11/z" 970 1,945 2,205 2,375 1,675 1,895 2,045 HU316 / HUC316 ✓ 29ti6 141/8 21/2 - (20) 0.162 x 31/z (8) 0.148 x 11/z 1,515 2,975 3,360 3,610 2,565 2,895 3,110 I8C, -n_" ya P MIU2.5fi/1$ -. 2�h6 i7?e=;: `2lz ' - 26 Q 162 x 31/za - ( ) 2 0,148 x 1 t/z - ( ) 230 . 3,745 4;045; 4;045"( 3�220"j 3,480 13,480 LA 21h x 20 MIU2.56/20 - 29/r61 193/6 121h - (28) 0.162 x 31h 1 (2) 0.148 x 11/z 1 230 14,030 4,060 4,060 3,465 13,49513,495 21ix22 MIU2.56I20 � ✓ 29/ie 197h6'' 21h (28) 6162.x 3M2 (2).0.748 X 11h 230 4,030 4 060 4;060, 3',465?(3,495 3,495 to 26 " 29ti6 x 91/4 29ti6" wide joists use the same hangers as 21/z" wide joists and have the same bads. to 26 /8, 0 "Yt� %� L'h.1 max. ' (It5) U.tbL x 3'h : , ou) U.14iS X 3 .:: -,et,. 4,t?UU IS,ULU� 3,LbU',G,3U5I Z,bUb `L,t1UU IBC, • - 31/8 111/a 2%. - (20) 0.162 x 31h (2) 0.148 x 11/z 230 2,880 3,135 3,135 2,475 2,695 2,695 FL, ✓ 31/8 109fie 21/z Max. (22) 0.162 x 31h (10) 0.148 x 3' 1,795 3;275' 3,695 3,970 2,820 j"3,180 3,425 LA ai/; °.ty a/' !'1) r9m r tn9 V a, 1ym AIAa Y R , : , �° a tm n nzn l d zzr"i i,m� l i a7n 1 � ���< FL IBC, FL W U3.G�- UJ = ._ • -'- ..3�1/41 .- (l b) '14. X L",/2 JUJ (iLJ. l4,,X'G vz JUyI' D,aOb b, GU" t,;;?,l U= , , 31;; 4ni54U "�,'t :3,4t)* HHUS46 - 3% 51/a 3 - (14) 0.162 x 31/2 (6) 0.162 x 31/z 1,320 2,785 3,155 3,405 2,395 2,715 2,930 31/z x 51/a HGUS46 • • - 35/8 06 4 - 20 0.162 x 31/z ( ) 1 (8) 0.162 x 3 /z 2,155 4,360 4,885 5,230 3,750 4,200 4,500 HUS48 •" - ' 3s�46 -"61616 2 ." = (6),0' 162x 31/ (6) 0.162 x 31/z 1,320 1,595 1,815 1,960 1,365 1,555 1,680 31h x 71/4 °HHUS48>. "°- • 3 /8 71/e ,,, " 3 : - , (2'2) C 162 x 3'%z , (8) 0.162 x 3"1/z"' ,78 }� .4;`210 '4,770{ 5;140 13;613 4,095 4,413 ;HGUS4$ •:. . '3$/s 7 4 "- (36) 4:162 x 31/2, , (12) 062 x 31h":', :3,235 T960 �460' 7,460 6415 J16,415 6,415a IUS3.56/9.5 - 35/6 91/z 2 - (10) 0.148 x 3 - 70 1,185 1,345 1,455 1.020 1,160 1,250 MIU3.56/9 • • - 39A6 813/16 21/2 - (16) 0.162 x 31/2 (2) 0.148 x 11/z 210 2,305 2,615 2,820 1,980 12,245 12,425 U410 ✓ 39/16 83/8 2 - (14) 0.162 x 31/z (6) 0.148 x 3 970 2,015 2,285 2,465 1,735 11,965 12,120 HUS410 - 39/is 87SAr 2 - (8) 0.162 x 31/z (8) 0.162 x 31/z 2,990 2,125 2,420 2,615 1.820 2,070 2,240 HHUS410 - 3% 9 3 - (30) 0.162 x 31/z (10) 0.162 x 31/z 3,565 5,635 6,380 6,445 4,845 5,486 5,545 31/z x 9Yz HU410/HUC410 • • • ✓ 39/is 8% 21/z - (36) 0.162 x 31/z (12) 0.162 x 31/z 3,235 7,460 7,460 7,460 6,415 6,415 6,415 HUC0410-SDS • • - 39As 9 3 - (12)114" x 21/z" SDS (6)114" x 21/z" SDS 21265 4,500 4,500 4,500 3,240 3,240 3,240 HGUS410 • • - 35/e 91/16 4 - (46) 0.162 x 31/z (16) 0.162 x 31/z 4,095 9,100 9,100 9,100 7,825 7,825 7,825 IBC, LGU3.63 SDS - 35/6 8 to 30 41/z - (16)1/4" x 21/z" SDS (12)1/4" x 21/z" SDS 5,555 6,720 6,720 6,720 4,840 14,840 4,840 LA MGU3.63-SDS • • - 35/a 91/4 to 30 1 41h I - (24)1/4" x 21h" SDS (16)1/4" x 21/z" SDS 7,260 9,450 97450 9,450 6,80516,805 6,805 1A %a:?. G /z % (GU) UJt3Z-X,3%z'" ; /) U.14?5 X 172 GIV 1z,tiou", I L,NJb U414 39f 6 j ' 10 2 _ "= " (16) 0.162 x 31/z'"' (6}.0.148 x3,' : 970 2,305 2,615' 2,820 1980" 2,24'5 2,425 3 9 3 .r - " (30) 0162 x 31/2 e (100.162 x 31h" 3 565 5,635 "6;380 6,445 4,895 { 5;486 5,545 0412 "` • • i gAd :101h 2" ._ (10),Q:162x31h`' (10)�0.162.x311iA31 5 2,660 3,025 3,2652,-27512,590 2,795' 117/e ; iHU412 J HUC412 ... � s 3 he 105/e'� , 2 /z Min Max (16);0.162 x 3?Jz (22);0;762x 31/z {6) 0198 x 3 " (10) 0;148 x 3 "; ' 1135 _?,r vy 2,380 3,�75 2,685 3;695 2 8'§ 3 970' 2;050 2,820 2,315 .3;180 2 490; 3,425' HUC0412-SDS = 39/te 11 , . `- (14)"1/V X 2?h". SDS {6)1/4" x HGUS412 35/8 107/�6 ` 4 ° - ° (56) 0:162 x 3?h ` (20)'0.162 x 31/2 5;040 9,400 9,400` 9,400 $085 } 8;085 8,085! =LGU3 63 SDS_ -", 35/a 8 t03Q 4?/z = (16)1/a",x 21/i' SDS (12)%4" x21h': SDS' 5,555' 6;720 6,720 6,720 4;840 4;840 14,840 ., .eAA('J I']G'-�:C(1C a•�i 5/ A All Nail 11.1- 1D, CNI /i L\'1Y.n „',jyLOl1R �1GA [1':fG» 11 nGIf AAGA�c'o,1 G'il one it nnG< 46 See footnotes on p.150. Simpson Strong-TieO Wood Construction Connectors Adjustable Truss Hangers This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower installed cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail,pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table Finish: Galvanized. Some products available in ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. The following installation methods may be used: • Top -Flange Installation — The straps must be'field formed over the header — see table for minimum top -flange requirements. Install top and face nails according to the table. Top nails shall not be within 1/4" from the edge of the top -flange members. For - the THA29; nails used for joist attachment must be driven at an - angle so that they penetrate through the corner of the joist and into the header. For all other top -flange installations, straighten the double -shear nailing tabs and install the nails straight into the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, with at least half of the required fasteners in the top half of the header. Not all nail holes in the straps.will be filled. Nails must have a minimum 1/2" edge distance. Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min.) installation option accommodates conditions where the supported member hangs either partially or entirely below the header. • Face -Mount (Max.) Installation — Install face nails according to the table. Not all nail holes in the straps will be filled except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift — Lowest face nails must be filled to achieve uplift loads. Options: • THA hangers available with the header flanges turned in for 3W (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart 13/a' for THAC422 for 122-2 126-2 THAC422 13/: typical 21h' for THA422-2 and THA426-2 THA418 Mir Face nails Top nails portable per table Double.42— 2face nails Use full table value (total) Single 42— 4 top nails See �:> (total) nailer table . • " %Y Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation. on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps may be installed straight or wrapped over with tabulated face nails installed into top and face of head ® Double -Shear ,�- Double- Nai6n s Dome Double -Shear Shear Side View; Nailing Side View Nailing Do not (Available on Top View I bend tab some models) Straighten the double shear nailing tabs and install nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation IYpjr ai I J lmcv Top Flange Installation -or to tnote 5 p.187 86 SIMPSON THA/THAC ..................................................................................................................................................................... ...,................... .................. ......................................................... _.......... _................................... _..... _....... Adjustable Truss Hangers (cont.) ID These products are available with additional corrosion protection. For more information, see p.15. KI 53 THA29 18 15/e 911A6 5y/s 11/2 - (2) 0.148 x 3 1 (6) 0.148 x 3 1 (4) 0.148 x 3 525 1 1,750 11,750 1 1,750 1 450 1,330 11,330 1 1,330 27%, - (4) 0.148 x 3 1 (6) 0.148 x 3 1 (4) 0.148 x 3 525 1 2:610.2.610 1 2,610 1 4561 11,985 11,985 1 1,985 THA218 18 1 % 17-46 51/z 1 2 - (4) 0148 x 3 (2)0.1480 (4) 0.148 x 11/z 11,460 1:4601 1,460 - 1; 10 1 11110 1,110 TNA2182 `. 6" 31/a 171146 (4}t%f62X3Yz'(2)0162x31h ,(6}0148X3 1,, 1 6„' 1,9 5.'~ IBC, FL, . ... __ .. LA THA222-2 16 3Ya 22Yts 8 2 - (4) 0.162 x 31h (2) 0.162 x 31h (6)0.148x3 1,960 1;995 1,895 - 1490 1,515 1,515 THA413-: 18. 3s/a 135A6 411z" 2 - (4)Q148x3 ''(2)0148X3 "(4)0148X3 i i.v3} 1,530 ` 1 30'° " - •. i,38o, 1,1k5 ' 1,1(�5 THA418 16 3% 171/z 77/a 2 - (4) 0.162 x 31/z (2) 0.162 x 31/z (6) 0.148 x 3 - 1.960 1;995 1,995 - 1490 1,515 1,515 THA426 14 3s/s 26 77/a 1 2 1 - (4) 0.162 x 3Yz (4) 0.162 x 3Yz (6) 0.162 x 31/zI 12,43512,4351 2,435 1 12,095_12,0951 2,095 THA422-2 71 7Ya 22t1tis 93/a`: 2 '' - -1(4)0.162x3'/21(4)0.162x3`/�1(6)0.162x3'hI (4� 0162 x 31h "(4) 0.162 x 31h (6) 0162 x 31h <' ,., * 3,330 3,330 '. 3;330 ' , - 2,865 2,865 2,865 FL THA426-2 14 7Ya 261/a 9a/a 2 - - 3,330 3,330 3,330 1 - 1 2,865 12,8651 2,865 THA29 18 1 % 911/s 51/a 1 9111is 13s '51h - THA213 18 THA218 18 11 s/a IMAJ 51/z 1 1 1 AA,, I- THA222-2 16 1 3Ya 22Y,s 8 1- 146 1- THA413 • 1$ 3s/a 13�s 41h 13g% THA418 16 1 35/a 1171h 1 77A6 1 - 141% 1- - THA426 1 14 1 3s/a 1 26 1 77/a I- 1 16% 1 - THA426-2 14 1 7% 261/s 9a/a 1 18 - (16) 0.148 x 3 1 (4) 0.148 x 3 1 525 12,26512.,2651 2,265 1 450 11950 11950 1 1950 (14) 0.148 x 3 °_(4) 0146 x 8°: 3` 2,u4a 2 340; ' ,450 . 73 - 6 2010 2108, (18) 0.148 x 3 (4) 0.148 x 3 855 2,450 2,450 2,450 735 2105 2105 2105 (22) 0162°x31h (6),0:1;62 X 31h _. t,855 �3�21 i 10 „ 1 , •;' -. 1595, 5'a 2,8 5 2,84 ' : IBC, (22) 0.162 x 31/z (6) 0.162 x 31h 1,855 3;310 3,310 3,310 1,595 2,845 2.845 2,845 FL LA (14)'0.148=x3. (4)0.148x8 `• ` 55 2,045 2;340 2,4"50 78 , 6G 2,0' 0 2,105 (22) 0.162 x 3Yz (6) 0.162 x 3Yz 1,855 3:310 3,310 3,310 1595 2:845 2,845 2,845 (30) 0.162 x 3Yz (6) 0.162 x 31h 1,855 4,415 4,480 4,480 1,595 3,795 3,855 3,855 (30) 0.1 62x31h (6) 0162 x 31h '1 855 5,170 5,520; ; , 5,520• ' -1 595 4,'445, 4,745' '4,745. ,, FL (38) 0.162 x 3Yz (6) 0.162 x 3Yz 1,855 5,520 5,520 5,520 1,595 4,745 4,745 4,745 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11/2" min. top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation loads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nails in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried Qoist) member. Based on the installation condition, nails will be installed either straight with straighted doubt -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. LUS/MUS/H US/H H US/H G US Face -Mount Joist Hangers This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost or a combination, of these features. The double -shear hanger series, ranging from the light -capacity LUS hangers to the highest -capacity HGUS hangers, feature nnovative double -shear nailing that distributes the load through iv�o poinls on each ;gist nail for greater strength, This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. • Not desidried fdF'welded or nailer applications. Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart Double -Shear Nairing Top View 1' for 2x' 1'fie"for4% o' m H �W B LUS28 HHUS210-2 HGUS28-2 MUS28 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) aba 19 0 WE �e LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers (cont.) d 1. See table below for allowable bads. = Model. No M1e, a Heel°' Ga Helga Dimerfs►ons (in j Fasteners B' Carrying �'-. Carried ;Member Member Single 2x Sizes LUS24 LUS26' .• �4?Is,-"r 18, 1% 31/a 131a1 (4) 0148 x 3•> > (2) 0.148 x 3 1s/ia . 43/a 1?7a. (4}40148x3�,� (4)'0.148x3 MUS26 4"/t6 18 1 9A 6 53A6 2 (6) 0.148 x 3 (6) 0.148 x 3 HUS26 45/ie 16 15/a 53/a 3 j (14) 0.162 x 31/2 (6) 0.162 x 31/2 HGUS26-_ 46Ae k' =12 e; ;:15%a 5a/e 5 ('Qto,162xW/z'. =(8)0,162x3l/2"' MUS28'. 4s ' 18"'�19/a° '-`651e '1?%a: "'(6)0.148X3") °(4)0:1�48X3, MUS28 6-A6 18 19A6 6'N6 2 (8) 0.148 x 3 (8) 0.148 x 3 HU 228 61/2 16 15/e 7 3 (22) 0.162 x 31/2 (8) 0.162 x 3'h HGUS28 69/ia 12 15/a 71/a 5 (36) 0.162 x 31/2 (12) 0.162 x 31h LUS210 " 411e ` 18' 19/a 7,1Y,a;, 13/a . ' ' {8) 014$ X 3 . (4) 0148 x 3 HUS210' '.;83/a`. ,1fi" 151a 79 - '-3,`-{30)0.162x,3'h,,.(10)0:162x3'h`° -HGUS210 8 f e_ 12� 15%, ;• ..T , .5 _(46) 0.1162 x 31h : "(16) 0.162 x.3'h' Uc These products are available with additional corrosion protection. For more information, see p.15. For stainless -steel fasteners, see p.21. Many of these products are approved for installation B with Strong-Drivee SD Connector screws. See pp. 335-337 for more information. LUS26 1 1,165 865 1 990 1,070 1 ;1,355 1,165 935 1,070 1.150 1,475 865 635 725 785 1,000 IBC, FL, °iVlUS26 3'u;,, , 1295..• 1,480='::1;560. ;i1,560, .° 1,405 ; °"1,560 ."1':8.,0' 1!;A�,^ , 810. 955.' 1,09,0; 1,180 _50:': LA HUS26 1,320 2,735 3,095 3,235 1 •3,235 1,320 2,960 31280 3:280 3,280 1,150 2,350 2,660 2,780 2,780 HGUS26 , ii - = 4;340' . •4,850._ �5,170 5390 " Ia �4,690 5,220' 5,346 , ""5390'" .780 "3,225' _3,610'< IBC, FL LUS28 1165 1100 1260 1350 1725 1165 1,195 1360 1,465 1,730 865 810 925 1,000 1,270 MUS28 a 1-. 1, 7 ill"., _,1 875 '... 212 , '', a255'"" € i 330 ; -i 1,87.5 " 1 2,135 >, a 2! 255 221 _ t. �a0 =1;2 0�: 1,455 '-1,575a _ 11 51 LA HUS28 1,760 4,095 4,095 4,095 4,095 1 1,760 4,095 4;095 4,095 4,095 1,480 1 3,520 3,520 3,520 3,520 HGUS28 .; ; 1,65G' 7,275' 7;275 " 7,2Z5 7,275,• 1,65� ' 7,275 /27� '; '7,275=' 2275 . 1;:825' ' 3 i f€ , 3,820 3,915"<,.4,250" IBC, FL LUS210 1,165 . 1,335 1,530 1,640 -2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,500 IBC, FL, HUS210; n�}5'. -15,450' S,, 95''' r4,830.' ... a,830 ,, � 53W 5,395, 5,780 ' �;830 . `,5,a3, 2 220 - ` 2;s'Q, ..2,..5 5 ., 2,535 . 2,82. LA HC-US210 2,09E 9:100 9,100 9:100 9,100 2,090 9,100 9100 9,100, 9.100 1,545 6,340 6,730 6,730 6 73 lIBC, FL 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp.98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45° and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 Ib. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are: HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table load 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load Acute -side bpeclly angle Top View HHUS Hanger Skewed Right Uoist must be bevel cut) All joist nails installed on the outside angle (non -acute side). 0 Z Q 0 0 O w H 0 Z O Cc Z m b N 0 m N U 0 94 Simpson Strong -Tie° Wood Construction Connectors tr+ng- These products are available with For stainless Many of these products are approved for installation Is additional corrosion protection. ® steel fasteners, E with Strong -Drive° SD Connector screws. For more information, see p.15. see p.21. See pp. 335-337 for more information. SS - a' Double 2x Sizes HHUS26-2 43'ia 14 35/ia 53/a 3 1 (14) 0.162 x 31/z (6) 0.162 x 31/z 1,320 2,830 13,190 3,415 14,25011,135 2,435 12,745 12,935 3,655 HGUS26-2 49tia 12 35/ie 57/ie 4 (20) 0.162 x 3'/z (8) 0.162 x 3'/z 2,155 4,340 4,850 5,170 5,575 1,855 3,730 4,170 4,445 4,795 LUS282ti --"' 4fia- 18 31/s "7 � "_,2. .{fi)0.162x3?/z' (4)0162x31h '.t 0 1315:< 1490 1610:.2,630 '6 ' 1,130" 1;280'1,385 1,745 IBC, FL UU1lcoo,O' I 'a4L. � Ie: osz_':..mr. - `; :roll n an-ov- ":.io) niao). 01� 1 7Pn a OaF": e.Qin-"a uC- G-loon. -v GAG-'o aten AVM n n r G 1nG'. LA LUS210-2 I 67t6 18 1 31/a 1 9 1 2 (8) 0.162 x 31/z 1 (6) 0.162 x 31/z 1,445 1,830 2,075 2,245 2,830 1;245 1,575 1,785 1,930 2,435 HHUS210-2 1 8N. 14 35/ia 1 87/a 3 (30) 0.162 x 31/z (10) 0.162 x 3'/z 3,550 5,705 6,435 6,485 6,485 1 3,335 1 4,905 5,340 5,060 5,190 HGUS210-2 8'ha 12 35/1a 1 9346 1 4 (46) 0.162 x 3'/z (16) 0.162 x 3'h 4,095 9,100 9,100 9,100 9,100 3,520 7,460 7,825 7,825 7,825 Triple 2x Sizes HGUS26 3 `^ 4��5"s -r12 4?is, , 5'h ,�,�4 ° (20).0.1fi2:x 3'!z "; {8) 0162: 31h • 2;156 ,4 34D;:: 4,850 5170 5 575 1,855? °3 730 4,70 , IBC, FL, HGUS28 3 ,' �. 613/a .. .. ;-12'' 4'Shc 7'fa , 4 (36) Q.162 x 3'%z "(12) 0:162 x 3'h 3,235 7-060" 7460 ;7;'460 7,460 2 78D.6 415 6,415 LA HHUS210-3 83/a 14 417/ia 87/a 3 (30) 0.162 x 31h (10) 0.162 x 3'/z 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 A7,8257,825 FL HGUS210-3 873/ia 12 415/i6 91/4 4 (46) 0.162 x 31/z (16) 0.162 x 3'h 20'0.162-X 3°!z 4,095 5,i 7 9,100 c ii4 9,100 0 9,100 L4 9,100 9G4 3,520 9t}0" 7,825 > t80 7,825 f;7iiU IBC FL Quadruple 2x Sizes HGU826 4 -->` - 51h"; 12 -(20)-UIU2 x 3'/z F'8) U.162 X 3'/z- . ;'L,T S, 4,340 4,tt5U ��l /U :5; I5: _7;iSbb, r3,I3U 1'4'1lu-4,4,',4b 4,/bO IBC, FL HGUS28-4 71A 12 6a/s 7%. 4 (36) 0.162 x 31h (12) 0.162 x 31h 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 LA HHUS210-4 83/e 1 14 6'/a 87/a 3 (30) 0.162 x 3'h (10) 0.162 x 31/z 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL 4x Sizes IBC, FL LA IBC, FL LUS48 4% 1 18 39/ia 63/4 1 2 1 (6) 0.162 x 3'h 1 (4) 0.162 x 31h 1'1'060 11,315 11,490 11,610 12,0301 910 11,130 11,280 11.38511,745 JIBC, FL, HUS48 6'A 14 39As 7 2 (6) 0.162 x 31h (6) 0.162 x 3'/z 1,320 1,580 1,790 1,930 2,415 i 135 1,360 1,540 1,660 2,075 LA HHUS48 6%. 14 35/a 71A 3 (22) 0.162 x 31/z (8) 0.162 x 31h 1,760 4,265 4,810 5,155 5,980 1,515 3,670 4,135 4,435 5,145 HGUS48 67k 12 35/a 71fa 4 (36) 0.162 x 31/z (12) 0.162 x 3'/z 3,235 17,460 17,460 7,460 7,460 2,780 16,415 16,415 6,415 6,415 HGUS412 10346 1 12 1 3% 1107isl 4 1 (56) 0.162 x 31/z (20) 0.162 x 3'/z 5,695 9:04519,045 19,045 9;045 14,900 17,780 17,780 17,780 17,780 HGUS414 111316 1 12 1 35/a 123i6 4 1 (66) 0.162 x 31/z (22) 0.162 x 3'/z 5,695 10,125 10,125 10,125 10,125 4,900 1 8,190 1 8,190 1 8,190 1 8,190 Double 4x Sizes I IBC, FL, LA FL 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govem. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSUTPI 1-2014. Simpson Strong -Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h" nails in the header and 0.162" x 31h" in the joist, with no load reduction. With single 2x carrying members, use 0.148" x 1'h" nails in the header and 0.148" x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 19 HTU Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/s". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is 1/e" per ASTM D1761 and D7147). See technical bulletin T C-HANGERGAP at strongtie.com for more information. Material: 16 gauge Finish: Galvanized Installation: • Use all specified fasteners; see General Notes • Can be installed filling round holes only, or filling round and triangle holes for maximum values • See alternate installation for applications using the HTU26 on a 2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity Options: • HTU may be skewed up to 671/2'. See Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong -Drive® SD fasteners. Codes: See p.12 for Code Reference Key Chart Min. heel height per table EUMany of these products are approved for installation with Strong -Drive' SD Connector screws. See pp. 335-337 for more information. Typical HTU26 Minimum Nailing Installation HTU26 �- /W max. gap between end of-- ---- truss and carrying member HTU Installation for Standard Allowable Loads (for 1/2" maximum gap, use Alternate Allowable Loads.) Standard Allowable Loads (1/8" Maximum Hanger Gap) HTU28 HTU28 2x Sizes 37/e 115/8 71/16 31/z 1 (26) 0.162 x 31/2 (14) 0.148 x 11/z 1 1,235 13,820 1 3,895 13,895 3,895 1,060 71/a 115/a 71tie 31/z 1 (26) 0.162 x 31/z (26) 0.148 x 11/z 12,020 13,820 1 4,315 - 4,655 5,435 1,7355 Double 2x Sizes 4 C Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HTU210 similar) 0,% IBC, 2,920 1 2,920 1 2,920 FL, 3,710 4,G05 4,675 LA HTU28-2 (Min.) 1 37/a l 35/i6 l 71A6 1 31/2 1 (26) 0.162 x 31/2 1 (14)0.148x3 11,530 13,820 14,310 14,310 14,310 1,315 12,865 13,235 3,235 13,235 HTU28-2 (Max.) 1 71/a 35/i6 71ti6' 31/2 1 (26) 0.162 x 31/z (26)0.1480 13,485 13,820 1 4,315 14,655 15,II25 2,995 13,285 30 .' 4_a05 1„55,010 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1/s' and 1h", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVFPl 1-2014. Simpson Strong -Tie Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. IBC, FL, LA 1*1 HTU Face -Mount Truss Hanger (cont.) II Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member Mm Fasteners (in } Model ' :Heel Minimum _ No ;Heightt Carrying 6arrymg Carved Uplifl Mem'ber, ads Sot Wind HTU26 (Min.) 37/a (2) 2x4 (10) 0.162 x 31/z 1 (14) 0.148 x 11h 1 925 1 1,470 1 1,660 1 1,790 1,875 795 1 1,265 1 1,430 1 1,540 1,615 HTU26 (Max.) 51/2 (2) 2x4 (10) 0.162 x 31h (20) 0.148 x 11/2 1,240 1 1,470 1,660 1 1,790 2,220 1065 1,265 1,430 1,540 1,910 IBC, HTU28 (Max.) - 71/4 (2} 2x6' (20) 0.162 x 31/ (26) 0.1148 x 11/2 '; 1 970' 2 y40 [_3,58'QQ 3,905 ' ,1,695; 2,530 '� 218855 . '3,080 3,360 ; FL, LA 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 1h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loads (1/2" Maximum Hanger Gap) Mm Dimensions fin.) 1 Fasteners (in) I OF/SP Allowable Loads SPF/HF Allowable.Loads Adel ueol .1 1-_`�[..,. ,.( 1 �'� Single 2x Sizes ``sq 2 85 2,88x1h25290wi,80HU2(Max) 57ti_2 1 IBC, HTU28 (Min.) 37/8 15/8 71/ie 31/2 (26)-0.162 x 31/2 (14) 0.148 x 11h 1,110 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL, LA HTU28 (Max.) 71/4 15/a 711A6 31/2 (26) 0.162 x 31/2 (26) 0.148 x 11/2 1,920 3,820 4,315 4,655 5,015 1,695 2,865 3,235 3,490 3,765 Double 2x Sizes HTU26=2 (Max:).' o a51/z 3Yie 5711e ' ..31h (20) 0162 x 3,Yz ;` (20)_0148 x $; = f;910 2 940 '3 , 34500 3,560 1;645 ;' 2,205 `Z205, 2,205 1 2;205 -' HTU28-2 (Min.) 37/8 35/ia 71/is 31/z 1 (26) 0.162 x 31/z (14) 0.148 x 3 1,490 3,820 3,980 3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC, HTU28-2 (Max.) 71/4 3-a I 7'Aii 1 31/2 (26) 0.162 x 31/2(26)0.148x3 3,035 3,820 4,315 4,655 5,520 2,610 2,865 3,235 3,490 4'LA' LA, 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1/a" and 1/2", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSUTPI 1-2014. Simpson Strong -Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11h" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 19 HU/HUC/HSUR/L got Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUC products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension is 25/16" or greater, at 100% of the table load. Specify HUC. • HU is available with one flange concealed when the W dimension is less than 25/16" at 100% of the table load. Specify as an `X' version and specify flange to conceal. • For any HU or HUC shown in this catalog, the user may substitute all face nails with 1/4" x 13/4" Titers® 2 screws (Model TTN2-25134H) for concrete and 'A" x 23/4'' Titer, 2 screws (Model TTN2-25234H) for GFCMU. Follow all installation instructions and use the loads from the sawn lumber or EWP sections. Material: 14 gauge Finish: Galvanized; ZMAX® and stainless steel available Installation: • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" — Model TTN2-25234H) and for concrete (1/4" x 13/4" — Model TTN2-25134H) are not provided with the hangers. • Drill the 3/1e"-diameter hole to the specified embedment depth plus'/2". • Alternatively, drill the 3/ie"-diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Titen Installation Tool lets are available. They include a Y11e" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/15" x 4'/2" drill bit is also available (Model, MDB18412). • A minimum edge distance of 11/2" and minimum end distance of 37/8" is required as shown in Figure 1 for,full uplift lad. • Where no uplift load is required, a minimum end distance of 11/2" is permitted. Codes: See p.12 for Code Reference Key Chart Concealed flanges �aILKIiL1• 1 HU214 Figure 1 — HUG410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 23 HU/HUC/HSUR/L .. . . ............. . ............ . ... . ........ . ................ . . . ....... . . . ............ . ............. . . . . . ....................................... ............. . .... ......... . ... ... .......................... . ....... . . . ........ . ......... Medium -Duty Face -Mount Hangers (cont.) 10 These products are available with additional corrosion protection. For more information, see p. 15. HU26 HU26X (4) 1/4 x 23/4 1 (4) 1/4 x 13/4 (2) 0.148 x 11/2 335 1,000 335 I 1,545 1 (4) Q,14§`?�! 14, 5 400 4/4 X 45, �_A,500�, �,-�760 H itl, x121�4 HU28X HU24-2 HUC24-2 (4) 1/4 x 23/4 (4) 1/4 x 13/4 (2) 0.148 x 3 380 -1,000 380 1,545 HU26-3 (Min.) HUC26-3 (Min.) (8) 1/4 x 23/4 (8) 1/4 x 13/4 1 (4) 0.148 x 3 760 2,000 760 1 3,200 H -3 (Max.) HUC26-3 (Max.) (12) IA x 2 -14 (12) 1A x 13/4 1 (6) 0.148 x 3 1,135 3,000 1,135 '950 U26 3,950 HU210 HU210X r (8)1/4 X 23/4 (8) 1/4 x 13/4 (4) 0.148 x 11/2 545 2,000 760 2.415 HU216 Min.),." IHIUC`216-� (Min)24 (14)4114x4 11 _P21Q, 210-2 (Max.) "/A *4'� ' , ' �1 , * - , , 614843 1 06'�' 18 , 4� 560, 100 i08,5 HU210-3 (Min.) HUG210-3 (Min.) (14) 1/4 x 2 3/4 (14) 114 x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210-3 (Max.) HUC2 10-3 (Max.) (18) 1/4 x 2 3/4 (18) 1/4 x 13/4 (10) 0.148 x 3 1,800 4,500 1,800 5,085 HU 21i� , 212X (10) IA i 2 '/I ' X 13/4 (6�,#A,4�_i� 1/2, 1,13 5" 2, 56o: 6 5- HU212-2 (Min.) HUC212-2 (Min.) (16) 1/4 x 2 3/4 (16) '14 X 13/4 (6) 0.148 x 3 1,135 4,000 1,135 4,920 HU212-2 (Max.) HUG212-2 (Max.) (2 2) 1/4 x 2 3/4 (2 2) 114 x 13/4 (10) 0.148 x 3 1,350 5,085 1,350 5,085 HU212-3 (Min .1 Ai HUC212,(Miin. 1/4 -(16), 1� W', 4,XT 0�148 I.i 135 4,920 H021273 "-'HUC212_ 3 2 '1�4 � i (22j (19) 9.148 X,',� lifloo 5' 085" ��J,Poor','�'_, -0 5 HU214 HU214X (12) 114 x 2% (12) IA x 13/4 (6) 0.148 x 11/2 1,135 2,665 1,135 2,665 HU214-3 (Min.) HUC214-3 (Min.) (18) 114 x 2 3/4 (18) 1/4 x 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 HU214-3 (Max.) HUC214-3 (Max.) (2 4) 1/4 x 2 3/4 (24) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 P216 21- (18)1/4 x 2 Y�, x 11/2: 2,920 -,,515, HU216-2 (Min.) HUC216-2 (Min.) (2 0) 114 x 2 3/4 (2 0) 114 x 13/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUC216-2 (Max.) (2 6) 114 x 2 -/4 (26) 114 x 13/4 (12) 0.148 x 3 1 2,015 5,085 2,01.5 5,085 HU7. (Min.) (Not available) (12) 114 x 2 3/4 (12) 1/4 x 13/4 (4) 0.148 x 11/2 545 2,980 760 2,980 HU7 (Max.) (Not available) (16) 1/4 x 2 3/4 (16) 1/4 x 13/4 (8) 0.148 x 1112 1,085 3,485 1,085 3,485 4 X 13/4 OA 773r236 (�4) ­k(-24) 1� 4 x VY4 4 45,� I HU11 (Min.) (Not available) (2 2) 1/4 x 2 3/4 (2 2) 1/4 x 13/4 (6) 0.148 x 11/2 1,135 3,230 1,135 3,230 HU11 (Max.) (Not available) (3 0) 114 x 2 3/4 (3 0) 114 x 13/4 (10) 0.148 x 11/2 1,445 3,735 1,445 3,735 Y4 ailabi ,,(2 8 i 44�, �4 3,4ig, HU 14, Y, (Max bi (Not available} �X � " 1, �(3 1/4 3/4 (3-6):/4,x44/f '0 148 *11/2, 04Y 2,01 5, 01 4,24 5 , , ­1 " 38 STAGGER JOINTS - TYP. UPLIFT/SHEAR ANGHOR-- I V�1 EACH TRUSS - SEE 5/SKI PLAN NOTE: ADDIL FRAMING NOT SHOWN FOR CLARITY RAISED HEEL TRUSS BEARING A SCALE. NTs SKI ,ED HEEL ROOF TRUSSES ROOF SHEATHING- SEE PLAN SOFFIT/FASCIA- SEE ARCI RAISED HEEL ROOF TRUSSES -SEE PLAN RIBBON BOARD- SEE SCHEDULE FOR SPACING a RIBBON BOARD- SEE FASTENING TO w N SCHEDULE FOR SPACING a TRUSSES FASTENING 70 TRUSSES WALL 5HEATHING-BEE PLAN - MIN. 15/32' CDX PLYWOOD OR F 1/16' OSB WITH 8d GUN NAILS MASONRY WALL- (0.131' X 2 1/2') ® 6' O.G. T UPLIFT/SHEAR CEILING - SEE PLAN RIBBON BOARDSS a SEE ANCHOR EACH SEE PLAN LAN4 TRUSS- 5EE PLAN SCHEDULE NOT FASTEN RIBBON.80ARD INTO END GRAIN OF ROOF TRUSS MASONRY WALL - BOTTOM CHORD SEE PLAN RAISED HEEL TRU55 BEARING B SCALE, NTS ^,7K1 RIBBON -SCHEDULE DESIGN CRITERIA RIBBON MATERIAL RIBBON SPACING RIBBON ATTACHMENT vult=165 MPH (2) 12d GUN (0.131' X 39 (vasd=128 MPH) 2X4 5PF02 24' TO EACH TRUSS, (4) EXP. B, NAILS AT JOINTS ENCLOSED vult=180 MPH (2) 12d GUN 10.131' X 3') (VasXP. MPH) 2X4 5PF"2 16, TO EACH TRUSS, (4) E EXP. G, ENCLOSED I I NAILS AT JOINTS SHEET TITLE waeoN onn ra �i aoovmuuc SHEET INFORMATION IOB No: blll D�iE 155�f4. I I.OB.I SK.1 M 1E I. .ALPI.N,-,E . .w'wAw' .001c6 January 1',Q),: 2,020', Carpenter penter Contractors of Affi6rlcd, lhc: 3 6" Avenue" W Winter,R' 4ven; Dear' if: as'comelb my attention, that -some questions were raised concerning d&fiice)qfsy54Zgable endirussest, al .lo wRor ffireaded tb& If t t&,gable,,ends:a.*reDver"cont,initQq$ sup '-,ort; �p 'A 4if with on ce fu d tlie-.lidlb� vide- y,'shedthed; n i 1'4p�,'o the, w farce no �Any i , u maging conned or plates' a, es':or vertiC_..ebg, 111E�q no'rep is required The only ' sup,port��21et ,Of loads'l-,dhdl")'nddddibonaI .,: If you Eve- 4n-y--, qu'- "e'stt'o'-ns',',,:"'pl-e-'as-e give me-a;call: Y, '6760:F.6rpm:bpVei 9blie 866, (dapd'q, FL 3"" 2.1 28 521 -;97,.90 422-,8685 This document teas been electronically signedusinga.Digital Signature . Printed evj copies ithout an original must jfi z be verified using the original electronic I 1 P GI C version. 1 L `_.ul4l tttiTA MRaa` ANITW OMPANY \ ....... .'t/ 08126/2020 .� �sC� ,�'�i'•.,�1 t�R���ff s�' N-Al. "lraw.aamTL Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone:(800)755-6001 www.alpineitw.com ftJ)nfornlatt�r . [Page 1. ustGmer; Carpenter Contractors of America Job Number. • N334501 Job Descri tion: 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Address: Job' En ineenn" Design Code: FBG 6th Edition (2017) lnteNVlEW Version: 17.02.02A through M02.01A JRef #: 1 WY589750042 Nind Standard ASCE 7-10 Wind Speed (mph): 160 Roof Load (pst) 20.00- 7.00- 0.00-1D:00 3uildin Type: Closed Floor Load s : None This package contains general notes pages, 33 truss drawing(s) and 5 detail(s). �ltem ` ; ttr�wing �4umber . `> Truss ' 1 239.20.1108.35758 Al 3 239.20.1108.35165 A2 5 239.20:1108.35352 A4 7 239.20.1108.35308 A6 9 239.20.1108.35367 A8 11 239.20.1108.35508 A10 13 239.20.11,08.35602 All 15 239.20.1108.34604 A14G 17 239.20.1108.35805 A16 19 239.20.1108,34526 C1GE 21 239.20.1108.36631 D2 23 239.20.1108,35897 V8 25 239.20.1108.35852 ER 27 239.20.1108.35945 EJ3 29 239.20.1108.35728 CJ3 31 239.20.1108.36054 CJ 1 A 33 239.20.1108.35975 HJ3 35 A18015ENC101014 37 GBLLETIN1014 Florida Certificate of Product Approval #FL1999 1#em, DratiNusg (+Luln6er . 7 t t►ss 2 239.20.1108.35710 A1A 4 23920.1108.34743 A3 6 239.20.1108.35601 A5 8 239.20. f 108.35164 A7 10 23920.1108.34790 A9 12 239.20.1108'.34821 Al2 14 239.20.1108.35133 A13 16 239.20.1108.34838' A15 18 239.20.1108.34509 B1GE 20 239..20.1108.36787 D1 22 239.20.1108.3664.7 D3G 24 239.20.1108.35867 V4 26 239.20:1108.35804 ERA 28 239.20.1418,53201 CJ5 30 239.20.,1108.35960 CJ1 32 239.20.1108.33979 HJ7 34 A16015ENC101014 36 GBLLETIN0118 38 VAL160101014 Printed 8/26/2020 2:21:08 PM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or 1310 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel. with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.ora. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. U# = user specified divisor for limiting span/deflection ratio for evaluation of actual Udefl value. Udefl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square .foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or.pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1 Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustiy.com. Page 3 of 3 Job Number: N334501 Ply: 1 SEQN: 7603 / T10 COMN Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 11 FROM: RWM DrwNo: 239.20.1108.35758 Truss Label: Al SSB / YK 08/26/2020 6'1"7 12'11"15 19'10' 26'8"1 33'6"9 39'8" 6'1'7 6'10"8 6'10'1 6'10'1 6'10"8 �1i 10 10' Loading Criteria (psQ Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 it Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/112013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. =5X5 E 39'8' 9'10" 9'10" 29'8" 10, 39'8"'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.222 K 999 360 B 1709 1308 / 961 / - / 445 / 8.0 Lu: NA Cs: NA VERT(TL): 0.547 K 999 240 H 1710 1308 / 961 / - /- / 8.0 Snow Duration: NA HORZ(LL): 0.081 J - - Wind reactions based on MWFRS HORZ(TL): 0.140 J B Min Brg Width Req = 2.0 Code / Misc Criteria Creep Factor: 2.0 H Min Brg Width Req = 2.0 Bldg Code: FBC 6th.ed 201 7Max TC CSI: 0.616 Bearings B & H are a rigid surface. TPI Std: 2014 Max BC CSI: 0.982 Bearings B & H require a seat plate. Rep Factors Used: Yes Max Web CSI: 0.527 Members not listed have forces less than 375# FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. WAVE VIEW Ver: 17.02.02A.1213.21 B - C 1488 - 3151 E - F 1102 - 2027 C - D 1387 - 2871 F - G 1387 -2872 D - E 1102 - 2027 G - H 1488 - 3153 4.,,. H...,,,,,,, 0 a° w1ki.°® COAb'1/01NAL. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2756 -1187 K -J 2276 - 889 L - K 2276 - 863 J- H 2757 -1187 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 539 - 206 K - F 485 - 745 D - K 485 - 744 F - J 540 - 206 E - K 1361 - 646 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlingshipping, installing.and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, byy TPI an SBCA) r sa shipping, practices prior to performing these functions. Installers shall provide temporarryY r BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a propperly ,lid ceilingq. Locations shown forpermanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, 67 or B10, fla. AooTv Dlates to each face of truss and position as shown above and on the JoinCDetails. unless noted otherwise. f�efer to a division of "I Hi 1, or for r acceptance any structure web sites: ALPINE: www.alpineitw.mm; TPI: his drawing,any failure to build the on this drawing or cover Le daqesign shown. The supiCaebdrty ALPINE .-Cw- 13723 Riverport Drive Suite 200 Maryland Heights, MO 630< Job Number: N334501 Ply: 1 SEQN: 7604 / T25 / COMN Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: ALS DrwNo: 239.20.1108.35710 Truss Label: A1A FV / WHK 08/26/2020 7'11'2 12' 17'112 19'10' 23'8' 31'8"14 398" 7'11"2 4'0'14 5'1'12 2'8'4 .1 8'0"14 7'11"2 =6x6 F E G g4X6 12 D (a) 6 n 'C3 a) H W9 T1 (a) W1 T w Q IV a 1 A zI 4X6(A2) -6X6 =___----_- =H0510(I) P 8X8(I) =8X10 K SECTION MAYBE REMOVE AFTER INSTALLATION. DO NOT CUT PLATES. 39'8" 3'10"15+ 5' 6'8' 8'0'11 1 + 12' + + 17' 23'8" 31'8"11 Loading Criteria (psf) Wind Criteria TOLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP. C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 8 GCp!: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N :Ti 2x4 SP #1: Bot chord 2x4 SP #2 N Webs 2x4 SP #3 :W3, W6, W9, W11 2x4 SP #2 N: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun naiis(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Plating Notes All plates are 2X4 except as noted. (1) - plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Wind Wind loads based on MWFRS with additional C&C member design. ro 0 J 39V 39'8' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.386 O 999 360 B 1556 / 308 / 961 / - / 445 / 8.0 Lu: NA Cs: NA VERT(TL): 1.101 O 706 240 1 1556 / 308 / 961 / - /- / 8.0 Snow Duration: NA HORZ(LL): 0.168 K - - Wind reactions based on MWFRS HORZ(TL): 0.314 K B Min Brg Width Req = 2.2 Code / Misc Criteria Creep Factor. 2.0 1 Min Brg Width Req = 2.2 Bldg Code: FBC 6th ed 201 Max TC CSI: 0.791 Bearings B & I are a rigid surface. TPI Std: 2014 Max BC CSI: 0.993 Bearings B & I require a seat plate. Rep Factors Used: Yes Max Web CSI: 0.958 Members not listed have forces less than 375# FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. WAVE, HS VIEW Ver: 17.02.02A.1213.21 B - C 1429 - 2745 F - G 1353 - 2068 C - D 2160 - 4245 G - H 1201 - 2103 D - E 1504 - 2794 H - I 1445 - 2777 E - F 1610 - 2771 M. rlk$p, Jj'r,,�Plbi. *NA9A9•i®• ipl� A F f M kT e �o •• s Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2371 -1106 L - K 2402 -1133 Q - M 3738 -1618 K - 1 2406 -1133 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - S 753 -1523 M - F 2007 -1002 C - Q 1476 - 556 M - L 1864 - 657 S - Q 2850 -1328 F - L 440 - 454 Q - D 1271 - 597 L - H 458 - 688 D - M 804 -1539 Including brace brae on BC dC above irectler ly abo24 ve both ends of fillas er COA #)(f'?� �A� � wsjA� 9 Y �p94ics0 (if no rigid diaphragm exists at that point). 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an c7 SBCA) fr safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 610, as applicable. Apply plates to each face of truss and position as shown above and on the Join[ Details, unless noted otherwise. kefer to drawings 16OA-Z for standard plate positions. Alpine, a division of • truss In conformanc listing this drawinc and use of this i For more information see I F'I 1, or for nanolln% snlppin9, mstl acceptance of pro essiona engi any structure is the responsibility ral notes page and these web sites: ALPINE: his drawing,any failure to build the on this drawing or cover page Le design shown. The suit -ability AL NE .—C m- 13723 Riverport Drive Suite 200 Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7605 / T9 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A51320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.36165 Truss Label: A2 SSB / WHK 08/26/2020 6'1"7 12'6"15 19, 6'1"7 6'S"8 6'5"1 10' 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 It GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5, W6 2x4 SP #2 N: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1 X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. :5X5? 5X5 E F 39'8" 9'10" 19'10" 2711 33'6"9 39'8" 1 6'1"7 9'10" 29'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.172 L 999 360 Lu: NA Cs: NA VERT(TL): 0.470 L 999 240 Snow Duration: NA HORZ(LL): 0.066 K - - HORZ(TL): 0.123 K Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th ed 201 Max TC CSI: 0.480 TPI Std: 2014 Max BC CSI: 0.856 Rep Factors Used: Yes Max Web CSI: 0.669 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 17.02.02A.1213.21 A 9 0 o ° r zk COA ON �1nt1r1t�t+ri�w 08/26/2020 10, 1' 39'8° r ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1556 / 309 / 964 / - / 428 / 8.0 1 1556 /309 /964 /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.8 1 Min Brg Width Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1511 - 2800 F - G 1123 -1779 C - D 1415 - 2521 G - H 1415 - 2521 D - E 1123 -1779 H - 1 1511 - 2800 E - F 1093 -1559 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2444 -1206 L - K 2030 - 941 M - L 2030 - 911 K -1 2444 -1216 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 508 -192 L - F 548 - 381 D - L 482 - 683 L - G 482 - 683 E - L 548 -381 G - K 508 -192 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for saiPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSt. Unless noted oyherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a properly attached rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracin Inslailed per BCSI sections B3, B7 or 910, as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE drawing s 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the u wc�,,,u,. truss in conformance with ANSI/l PI 1, or for handlingq,' shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , 13723 Rive ort Drive listing this drawing indicates acceptance of o) essionall engineering responsibility solely for the design shown. The suiE9ability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 200 For more information see this job's general notes page and these web sites: ALPINE: w .alpineitw.mm• TPI:—Apinst.org; SBCA: www.sbcindusirycom• ICC: www.Iccsafe.org Maryland Heights, MO 63042 1 Job Number: N334501 Ply: 1 SEQN: 7606 / T22 / HIPS Cust: R8975 JRef: 1WY689750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.34743 Truss Label: A3 FV / FV 08/26/2020 6'1"7 12'0"15 18'0"1 217"15 27'7"1 33'6"9 39'8" i 6'1'7 511"9 5'11"2 + 3'7"14 5'11"9 + 6'1"7 �1 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 10, 10, Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 5X5 =5X5 E F 9'10" 19,10" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N) Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed 201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/l0(0) Plate Type(s): WAVE 39'8" 9'10" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.171 L 999 360 VERT(TL): 0.467 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.124 K Creep Factor. 2.0 Max TC CSI: 0.415 Max BC CSI: 0.857 Max Web CSI: 0.541 VIEW Ver. 17.02.02A.1 213.21 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5, W6 2x4 SP #2 N: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR ptttautf12g1/1'41 restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab tiC tdtl4 t it reinforcement to be same size, species, grade, and 80% Ile gth of web member. Attach with 0.128x3" gun �e®a•p4•=,m i nails 6" oc. Wind s U.,Q8 I Wind loads based on MWFRS with additional C&C a member design. ` s �AT Oo Df�I qq yyyyqqqq 8 'gyp COA ff AU 2WHenl ° 08/26/2020 10' 1' 39'8" r ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1556 / 312 / 965 / - / 408 18.0 1 1556 1312 /965 /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.8 1 Min Brg Width Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - C 1540 - 2796 F - G 1154 -1794 C - D 1447 - 2523 G - H 1448 - 2523 D - E 1154 -1794 H - 1 1540 - 2796 E - F 1150 -1635 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2439 -1231 L - K 2064 -1000 M - L 2064 - 971 K - 1 2439 -1252 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 495 -180 L - F 523 - 335 D - L 470 - 674 L - G 470 - 674 E - L 523 - 335 G - K 495 -180 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI anc7 SBCA) for safely practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracingq installed per BCSI sections B3, 87 or 810, as applicable. Apply lates to each face oftrussand position as shown above and on the Join Details, unless noted otherwise. f7efer to ALPINE drawings 160A-Z far s�andard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be reN sible for any deviation from this drawing,any failure to build the AN wce,�,,,,,,. truss in conformance with ANSIl1 PI 1, or for handling shipping, installatnd bracing of trussesA seal on this drawing or cover pa e , , 73723 Rive ort Drive listing this drawing indicates acceptance of pro7essronat engineeresponsibility solely for the design shown. The suiE9abrlrty and use of this c7�awing for any structure is the responsibility of tuilding Designer per ANSI/TPI 1 Sec.2. Suite 200 Far more information see this'ob's eneral notes a e and these web sites: ALPINE: www.al ineitw.com: TPI: www.t inst.or : SBCA: www.sbcindust .cam; ICC: -iccsafe.ora Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SECiN: 7607 / T8 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E City: 1 FROM: RWM DrwNo: 239.20.1108.35352 Truss Label: A4 FV / WHK 08/2612020 7'10"14 17' 228" 31'9"2 39'8" -I r T10"14 9'1"2 5'8" i' 9'1"2 i' 7'10"14 .5X5 =5X5 D E 39'8" �1'+ 10' + 9110" 9110" 10 19,10" 29'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.149 J 999 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.408 J 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.060 1 - - EXP: C HORZ TL : 0.112 1 Des .00 Mean Height: 15.00 ft ( ) NCBCLL: 10.00 Code / Misc Criteria Creep Factor. 2.0 TCDL: 4.2 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.760 Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.863 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.629 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE VIEW Ver. 17.02.02A.1213.21 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N :T2, T4 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 Webs 2x4 SP #2 N :W1, W6 2x4 SP #3: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement nt may bscab for ( j 2 CLIR and used in lieu CLR ttttfltttllt gntt� { restraint. for (2) CLR'S where shown. Scab scabs reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun as°� si °•, �. r nails @ 6" oc. r °o Wind Wind loads based on MWFRS with additional C&C s sr o' /9 Q$ I member design. s , d m 44 ` COABONAL"+, 811114"1 08/26/2020 10, 39'8" ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1552 / 318 / 965 / - / 387 / 8.0 G 1552 /318 /965 /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.8 G Min Brg Width Req = 1.8 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - C 1532 - 2755 E - F 1559 - 2561 C - D 1559 - 2561 F - G 1532 - 2755 D - E 1205 -1728 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 2393 -1221 J - 1 1695 - 768 K - J 1695 - 738 I - G 2393 -1250 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 404 - 448 J - E 389 - 234 K - D 770 -462 E - 1 770 -462 D - J 388 - 234 I - F 403 - 448 **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing. and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byv TPI an SBCA) toy sa ety practices prior to performing these functions. Installers shall provide temporarryv bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracingq installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join f Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildino Components Group Inc. shall not be responsible for anv deviation from this drawing any failure to build the 11111 1, or for IF acceptance any sructure L seal on this drawing or cover page for the design shown. The suiFabddy ALPINE —COM — 13723 Riverport Drive Suite 200 Maryland Heights, MO 63043 Job Number: N334501 Ply: 1 SEON: 7608 / T24 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Oty: 1 FROM: RWM DrwNo: 239.20.1108.35601 Truss Label: A5 FV / WHK 08/26/2020 6'1"7 6'1"7 �1' + 10, 10, Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N :T2, T4 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 Webs 2x4 SP #2 N : W 1, W 6 2x4 SP #3: Lumber value set "l313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. listing and u For mou 16'0"1 237"T 9110"10 + 7714 6X6 ; 6X6 D E 39'8" 9110" i 1992 " 3379 39'8" 9110"10 + 6'1"7 10, 1' 39'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.156 J 999 360 B 1556 / 713 / 964 ! - / 367 / 8.0 Lu: NA Cs: NA VERT(TL): 0.427 J 999 240 G 1556 / 713 / 964 / - / - / 8.0 Snow Duration: NA HORZ(LL): 0.064 1 - - Wind reactions based on MWFRS HORZ(TL): 0.119 1 B Min Brg Width Req = 1.8 Code / Misc Criteria Creep Factor. 2.0 G Min Brg Width Req = 1.8 Bldg Code: FBC 6th ed 201 Max TC CSI: 0.799 Bearings B & G are a rigid surface. TPI Sid: 2014 Max BC CSI: 0.855 Bearings B & G require a seat plate. Rep Factors Used: Yes Max Web CSI: 0.614 Members not listed have forces less than 375# FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. WAVE VIEW Ver: 17.02.02A.1213.21 B - C 1622 -2852 E - F 1483 -2513 C - D 1483 - 2513 F - G 1621 - 2852 D - E 1254 -1829 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 2505 -1330 J - 1 1780 - 840 K - J 1780 - 810 I - G 2505 -1359 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 423 - 469 J - E 381 - 218 K-D 617 -314 E-I 617 -314 D - J 380 - 218 I - F 423 - 469 s ' 9 s 6 0 a. 708 1 ` s SAT 0 s o � COAL 0 AL e� �+retWmsrua;s'o- 08/26/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS > require extreme care in fabricating, handlin shi ping, installing.and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety. Information, by TPI and SBCA) for ME ty practices prior to performing these functions. Installers shall provide temporary per BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly d rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, icable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. (Refer to ALPINE Is 160A-Z for standard plate positions. �LPP �I NN a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the µ ,.,cgs,,,,,,, conformance with ANSI/TPI 1, or for handlin, shippintq, installation and bracing of trussesA seal on this drawing or cover page , , 13723 Riverport Drive this drawing, indicates acceptance of ppro essronar engineering responsibility solely for the design shown. The suitability ;e of this d►awing for any structure is fhe responsibility of the Building Designer per ANSIrrPI 1 Sec.2. Suite 200 information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinsl.org• SBCA: www.sbcindustryxom• ICC: wwwJccsafe.orq Maryland Heights, MO 6304 e Job Number: N334501 Ply: 1 SEQN: 7609 / T7 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.35308 Truss Label: A6 KD / FV 08/26/2020 710'14 15' 24'8" 31'9"2 39'8" 7' 10"14 + + + 7'1 "2 9'8" 7' 1 "2 7' 10"14 :6DX6 T3 =6E 12 6 C 5 SXS F in _o W 20 W1 B G t A H —I �_' I 4X6(A2) =5X5 =5X5 =5X5 =4X6(A2) 39'8" 10' 9'10" I_ 9110" 10' 1� �1'+ 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.159 J 999 360 B 1552 / 328 / 962 / - / 346 18.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.436 J 999 240 G 1552 / 328 / 962 / - /- 18.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.061 1 - - Wind reactions based on MWFRS EXP: C Des HORZ L 0.115 1 B Min Brg Width Req = 1.8 ) .00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 G Min Brg Width Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bearings B & G are a rigid surface. Bldg Code: FBC 6th ed 201 Max TC CSI: 0.913 9 9 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.867 Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 It Rep Factors Used: Yes Max Web CSI: 0.572 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver. 17.02.02A.1213.21 B - C 1547 -2729 E - F 1568 -2537 Lumber C - D 1568 - 2538 F - G 1547 - 2729 Value Set: 13B (Effective 6/1/2013) D - E 1287 -1910 Top chord 2x4 SP #2 N :T3 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #2 N :W1, W6 2x4 SP #3: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1/30/2013 by ALSC B - K 2363 -1228 J -1 1847 - 899 K - J 1847 - 870 I - G 2363 -1257 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. K - D 628 - 363 E - I 628 - 363 �1lultPlluJtJaJa Jf ff Ja�ar t � � `3i dg ® jt® s• 4 o.7Q� 9 ® s �I•+ +® o COAT ONAt� \ � a39af6Nf�tp`�1 08/26/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an8 SBCA) tpr safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSL Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracincl insTalled per BCSI sections B3, B7 or B10, _ as applicable. Apply totes to each face of truss and position drawings 160A-Z for sVandard plate positions. as shown above and on the JomflDetails, unless noted otherwise. kefer to � ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the m•ra, truss in ANSIJI PI 1, for handlin installation bracing trussesA this drawing conformance with or shipping, and of seal on or cover pae 13723 Riverport Drive Iisting this drawing indicates acceptance of pro esslona engineering responsibility solely for the design shown. The sui ability drawing, Suite 200 and use of this for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2, Far more information see this job's general notes page and these web sites: ALPINE: www.al ineilw.wrn; TPI: www.l insl.or ; SBCA: www.sbcindust .com; ICC: wwwAccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7610 / T23 / HIPS Cusl: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.35164 Truss Label: A7 FV / WHK 08/26/2020 6'1"7 14'0"1 19'10" 25'7"15 33'6"9 39'8" 6'1"7 7'10"10 5'9"15 5'9"15 7'10"l0 6'1"7 5X5 1112X4 .5X5 D E F T2 12 6 7- T4 5CX5 Z !;: \ 5G5 LO r` W 3 m B H A I 4X6(A2) =5X5 =5X8 =5X5=4X6(A2) 39'8" 10' 9'10" 9110" 10, 10' 19,10" 29'8" +1'� 3918" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.176 E 999 360 B 1556 / 715 / 958 / - / 326 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.482 E 999. 240 H 1556 / 715 /958 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.121 J - - Mean Height: 15.00 It B Min Brg Width Req = 1.8 NCBCLL: 10.00 Code / Misc Criteria Creep Factor: 2.0 TCDL: 4.2 psf H Min Brg Width Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.743 Bearings B & H are a rigid surface. g g Load Duration: 1.25 TPI Std: 2014 Max BC CSI: 0.859 MWFRS Parallel Dist: h/2 to h Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.322 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1632 -2822 E - F 1405 -2112 C-D 1510 -2515 F-G 1510 -2515 Value Set: 13B (Effective 6/1/2013) D - E 1405 -2112 G - H 1632 -2822 Top chord 2x4 SP #2 N :T2, T4 2x4 SP #1: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1/30/2013 by ALSC B - L 2470 -1332 K - J 1912 - 950 L - K 1912 - 920 J- H 2470 -1362 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. C - L 366 - 395 K - F 383 -177 L - D 556 - 253 F - J 556 - 253 D - K 382 -177 J - G 365 - 395 tcllufaanlaaarjara Y O 9D 8 9 a o. T. U O i Pi V ✓R { V e � ..q COA VV{{s0�U,te�4V»+� �eae�ae'a°� 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, bVv TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarryy bracing per BCSI. Unless noted oiherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigqid ceiling Locations shown forpermanent lateral restraint of webs shall have bracingQ installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. (Refer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the * ,,.,�o,,,,,,,,. truss in 1, for conformance with ANSI/TPI or handling, shipping, installation and bracing of trussesA seal on this drawing or listing this drawing indicates acceptance of pro) essionaf engineering responsibility solely for the design shown. this drawing for cover pa a .. 13723 Rive ort Drive The suit9ability Suite 200 and use of any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2., For more information see this job's general notes page and these web sites: ALPINE: —.al ineibv.mm; TPI: www.t inst.or ; SBCA: w .sbcindust .corn: ICC: w Jccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7611 / T6 1 HIPS Cusl: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qly: 1 FROM: RWM DrwNo: 239.20.1108.35367 Truss Label: A8 FV / WHK 08/26/2020 6'9"4 13' 19'10" 26'8" 32'10"12 39'8" + + 6'94 6'2"12 6'10" 6'10" + 6'2"12 674 5X5 1112X4 = 5X5 D E F 12 6 �2X4 W C 02X4 o_ G io W3i� t B H A !� 4X6(A2) =5X5 =5X8 =5X5 =4X6(A2) 39'8" �1'+ 10' 9110" 9110" 10, + + 10' 19,10" 297 +1'� + 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.191 E 999 360 B 1556 / 716 / 953 / - / 305 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.523 E 999. 240 H 1556 / 716 / 953 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.121 J - - Mean Height: 15.00 ft B Min Brg Width Req = 1.8 Code / Misc Criteria CreepFactor. 2.0 NCBCLL:10.00 TCDL:4.2 psf p H Min Br Width Re 1.8 g q Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.502 Bearings B & H are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI.Std: 2014 Max BC CSI: 0.864 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 it Rep Factors Used: Yes Max Web CSI: 0.431 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1617 -2780 E - F 1504 -2289 C - D 1545 - 2523 F - G 1544 - 2523 Value Set: 13B (Effective 6/1/2013) D - E 1504 -2289 G - H 1616 -2780 Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1/30/2013 by ALSC B - L 2421 -1306 K - J 1982 -1003 L - K 1982 - 973 J- H 2421 -1335 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. L - D 535 - 255 K - F 425 - 251 D - K 425 - 251 F - J 535 - 255 E - K 306 - 391 tgtttitiiittiN)1tJlllyt�fl{A 4. T08 9 a o i ! w SAT fl ��U 6•ifB*9a pA®•'� COA ( `r 101YA .t 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI for an� SBCA) saty practices prior to performing these functions. Installers shall provide bracing per BCSI. Unless noted olherwise,top chord shall have attached structural sheathing and bottom chord temporary have properly shall a properly attache tl riqid ceiling Locations shown for permanent lateral restraint of webs shall have bracinci ins ailed per BCSI sections B3, B7 or 810, _ as applicable. Apply lates to each face of truss and position as shown above and on the JoinCDetails, unless noted otherwise. kefer to drawings 160A-Z for s�andard plate positions. ALPINE^ Alpine, a division of ITW BuildingCcmponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the -CO-- truss in ANSIPI1, for conformance with or handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , 13723 Rive ort Drive listing this drawing indicates acceptance of pro) essionai engineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the the Building Designer ANSI/TPI Suite 200 responsibility of per 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or : SBCA: www.sbcindust xom; ICC: www.iccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEON: 7612 / T21 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Oty: 1 FROM: RWM DrwNo: 239.20.1108.34790 Truss Label: A9 FV / WHK 08/26/2020 6'3"4 12'0"1 19'10" 27'7"15 33'4"12 39'8" 6'34 5'8"12 7'9"15 7715 5'8"12 6'3"5 .5X5 1112X4 =5X5 D E F T12 T 6 � �2C4 W i2G M u2 V o W3 m B H A I � 4X6(A2) -5X5 =5X8 =5X5=4X6(A2) 39'8" 1' 10' 9110" 9110" 10, 1' i' T 10' 19110" T 29'8" 39,8" 'i Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.206 E 999 360 B 1556 / 717 / 947 / - / 285 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.564 E 999 240 H 1556 / 717 / 947 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.066 J - - Wind reactions based on MWFRS EXP: C HORZ TL 0.124 J Des Ld: 37.00 Mean Height: 15.00 It( ) B Min Br Width Re 1.8 q NCBCLL: 10.00 Code / Misc Criteria Creep Factor. 2.0 TCDL: 4.psf H Min Brg 9 Width Reg = 1.8 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.698 9 Bearings B 8 H are a rigid surface.Soffit: Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.865 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 It Rep Factors Used: Yes Max Web CSI: 0.610 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 It FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B-C 1642-2791 E-F 1617 -2492 C - D 1543 - 2524 F - G 1543 - 2524 Value Set: 13B (Effective 6/1/2013) D - E 1617 -2492 G - H 1642 -2791 Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1/30/2013 by ALSC B - L 2434 -1333 K - J 2065 -1064 L - K 2065 -1034 J- H 2434 -1362 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. L - D 498 -203 K - F 639 - 324 D - K 539 - 324 F - J 498 - 203 E - K 361 -462 �►itHr�tijla6ltltvhfrrr s�t� Ala ,��/fr �4idMtlW�q ail �T o e o. 7.0U q S ' -• ro • �+ p4 r � i m i y} pa� era�r ns•#� '� `ate ({ 'S OVAL COA '++uarrfeaaf� 08/26/2020 "WARNING"' READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI ani SBCA) for saly practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper y 910, attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. (Refer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure truss in ANSIIT PI 1, for handling, to build the ,,�.re,,,,,,n,. conformance with or shipping, installation and bracing of trussesA seal on this drawing or listing this drawing, indicates acceptance of o) essionat engineering responsibility solely for the design shown. and use this a►awing for is p the cover page , , 13723 Rive ort Drive The suitability Suite 200 of any structure e responsibility of Building Designer per ANSI(TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or ; SBCA: www.sbdndusl xom; ICC: www.Iccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7613 ! T5 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.35508 Truss Label: A10 FV ! WHK 08/26/2020 28'8" 33'10"12I 3 " r "5212 899'8" 94554 5'2"12 59'99 ;5DX5 =5X5 �5F5 T3 12 T 6 •2X4 W 2X4 C o G `o n W3 B 1 g A H 4X6(A2) =5X5 =5X8 =5X5 =4X6(A2) 11 39'8" 10' 9110" 9110" 10, 10' 19,10" 29'8" +1'� 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in Ioc Udell L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.213 E 999 360 B 1556 / 718 / 940 / - / 264 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.584 E 999 240 H 1556 / 718 / 940 ! - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP' C HORZ(TL): 0.127 J Mean Height: 15.00 ft B Min Big Width Req = 1.8 Code / Misc Criteria Creep Factor: 2.0 NCBCLL: 10.00 P TCDL: 4.2 psf H Min Big Width Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ad 201 Max TC CSI: 0.870 Bearings B & H are a rigid surface. 9 9 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.865 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.969 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCp!: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1669 -2804 E - F 1721 -2693 C - D 1547 - 2533 F - G 1552 - 2539 Value Set: 13B (Effective 6/1/2013) D - E 1783 -2773 G - H 1663 -2797 Top chord 2x4 SP #2 N :T3 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "13B" uses design values approved 1/30/2013 by ALSC B - L 2448 -1362 K - J 2163 -1134 L - K 2147 -1091 J - H 2440 -1384 Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply (Ibs) member design. Webs Tens.Comp. Webs Tens. Comp. L - D 470 -163 K - F 626 - 371 D - K 739 -462 F - J 466 -151 E-K 419 -534 ytnttttntuarrrrr rfrfri o w s o7,08 n r � S i py 0 v�� T11 ►��.'� i e �°6 d COA AL 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin'shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI and SBCA) for saty practices poor to performing these functions. Installers shall provide temposrrVy bracing per BCSI. Unless noted otherwise,top chord shall have property attached structural sheathing and bottom chord shall have a properly attachetl ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections 83, B7 or B10, as applicable. Applgy plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW BuildingqComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in ANSI 1, for conformance with or handlin shippin , installation and bracing of trussesA seal on this drawing or cover pa e , , 13723 Rive ort Drive listingthis drawing indicates acceptance of proessiona engmeerinq responsibility solely for the design shown. The suit9abtlity this drawing, for the Suite 200 and se of any structure is responsibility of the Building Designer per ANSI/TPI 1 Sec.2.' For more information see this job's general notes page and these web sites: ALPINE: www.al ineit..wm; TPI: www.t instxr ; SBCA: www.sbcindusl .com; ICQ www.iccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7614 / T4 / HIPS Cusl: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.34821 Truss Label: Al2 FV / WHK 08/26/2020 9' 17' 30'8" 39'8" 91 s5C5 T2 =5XD5 =4E4 T3 =5F5 T 12 6 T o (a) W (a) B W5 G I�I 1A H1 =4X6(A2) =-6X6 =6X6 =6X6 =4X6(A2) 39'8" 9110" 9110" 10, 1 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Deff/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.251 J 999 360 B 1556 / 720 / 921 / - / 223 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.687 J 999 240 G 1556 / 720 / 921 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 1 - - Wind reactions based on MWFRS EXP: C Des Ld: 37.00 Mean Height: 15.00 ft HORZ L 0.150 1 R )� B Min Br Width Re 1.8 9 q = NCBCLL: 00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 G Min Brg Width Req = 1.8 . Soffit: 000 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.939 Bearings B & G are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Sid: 2014 Max BC CSI: 0.897 Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.306 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1595 -2705 E - F 1607 -2478 C - D 1608 - 2478 F - G 1595 - 2704 Value Set: 13B (Effective 6/1/2013) D - E 2001 -3233 Top chord 2x4 SP #1 :T2, T3 2x4 SP #2 N: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W2, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC B - K 2330 -1246 J -1 3176 -1733 K - J 3174 -1732 I - G 2329 -1275 Bracing (a) 1X4 #3SR8 or better continuous lateral restraint Maximum Web Forces Per Ply (Ibs) to be equally spaced. Attach with (2) 8d Box or Gun Webs Tens.Comp. Webs Tens. Comp. nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable C - K 718 -313 E - 1 529 -834 support by erection contractor. K - D 527 -832 I - F 718 -314 (a) or scab reinforcement may be used in lieu of CLR 0111111101141101" Jt restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab ar�4 0 H. , H reinforcement to be same size, species, grade, and 1' \� "a®aaa,e.■° '✓,f 80% length of web member. Attach with 0.128x3" gun + . am°� F- S'■"* "\,r '% . nails @ 6" oc. 3a fie° Y Wind r' 017,08 1 Wind loads based on MWFRS with additional C&C ° member design. z ■ a u � � i*a � i1 i lJ a■ �W ONAL COA lti 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, Component Safety. installing and bracing. Refer to and follow the latest edition of BCSI (Building Information, by TPI anc� SBCA) for saty practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceilin Locations shown fortpermanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, as applicable. Apply prates to each face o truss and position as shown above and on the Joinf9Details, unless noted otherwise. kefer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW BuildingComponents Group Inc. truss in with ANSIPI1, for handlin% shall not be responsible for any deviation from this drawing,any failure installation bracing to build the conformance or shipping, and of trussesA seal on this drawing or listing this drawing indicates acceptance of proessfonat engineering responsibility solely for the design shown. this drawing for is the cover page , , 13723 Riverport Drive The suitabrltty Suite 200 and use of any structure a responsibility of building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.al ineltw.mm; TPI: www.t inst.or ; SBCA: www.sbcindust .com; ICC: w Jccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7616 / T2 / SPEC Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E City: 1 FROM: RWM DrwNo: 239.20.1108.35602 Truss Label: A11 FV / WHK 08/26/2020 5'7"4 10'8" 1 ('3"15 16'0"1 23'7"15 29'7"15 39'8" 7.4I 5'0"12 T 15 4'8"2 7'7"14 6' 10'0"1 =5X5 5E5 D=4F4 == 5X5 5X5 12 6 � •2X4P T TT C zo�, rn T5 v U) B I � l�A Jit 4X6(A2) = SS 1017 =5X5 = 5X10 =3X6(A1) 39'8" 10' 9110" 9110" 10, 1 10' 19110" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 L 999 360 B 1556 / 716 / 933 / - / 257 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.625 L 999 240 1 1556 / 718 / 930 / - /- / 8.0 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.076 K - - Wind reactions based on MWFRS Des Ld: 37.00 EXP' C HORZ(TL): 0.142 K B Min Brg Width Req = 1.8 NCBCLL: 10.00 Mean Height: 15.00 It Code / Misc Criteria Creep Factor: 2.0 1 Min Brg Width Req = 1.8 TCDL: 4.2 psf Bearings B & I are a rigid surface. Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.820 9 9 p Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Sid: 2014 Max BC CSI: 0.866 Bearings B & I require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.811 Members not listed have forces less than 375# Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE, 18SS VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1690 -2806 F - G 1810 -2878 C - D 1552 - 2521 G - H 1529 - 2305 Value Set: 13B (Effective 6/1/2013) D - E 1443 -2214 H - 1 1548 -2649 Top chord 2x4 SP #2 N :T5 2x4 SP 2400f-2.OE: E - F 1486 -2258 Bot chord 2x4 SP #1 Webs 2x4 SP #3 Maximum Bot Chord Forces Per Ply (Ibs) Lumber value set "13B" uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/3012013 by ALSC B - M 2452 -1376 L - K 2805 -1515 Wind M-L 2814-1517 K-1 2266 -1220 Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 1699 -1052 G - K 435 - 669 tltuyymtsarfaue M - E 597 -872 K- H 693 -314 IlrJp�t ' r+�i M - F 499 - 742 #' a o y o.708 q # • 4##a-a00Yn•aa a#sue®1` `ts tout 08/26/2020 -WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI an, SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted othenvise,top chord shall have properly attached structural sheathing and bottom chord shall have a properr y attached rigid ceilincl Locations shown for permanent lateral restraint of webs shall have bracing Installed per BCSI sections B3, B7 or 610, _ Apply face as applicable. lates to each of truss and position as shown above and on the JoingDeta'Is' unless noted otherwise. f�efer to drawings 160A-Z for s�andard plate positions. �LPP �I NN ALPINE Alpine, a division of ITW BuildinIComponents Group Inc. shall not be responsible for any deviation from this drawing,any taiture to build the a aro ,a truss in conformance with ANSII 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa e . , 13723 Rive ort Drive I this drawing indicatescceptance of proTesstonar engineering responsibility solely for the design shown. The suit9abtlttyand Suite 200 this yawing fory use of structure is the responsibility of the building Designer per ANSIITPI 1 Sec.2., For more information see this'ab's eneral notes a e and these web sites: ALPINE: www.al ineihv.wm; TPI: www.l inst.or ; SBCA: www.sbcindust .corn; ICC: w Accsafe_ara Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7636 ! T20 / COMN Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALIAEBB ELEV.C,E City: 1 FROM: RWM DrwNo: 239.20.1108.35133 Truss Label: A13 FV / WHK 08/26/2020 5'7"4 10'8" 13'3"15 2115 31'7"15 39'8" 5'74 5'0"12 2'7"1 8'4" 10, 810"1 D T 12 6 �2X4 E T3 =HOF10 T4 =6G6 T TT P 0o W bn B A (a) o v rD H I 1 =3X6(A1) B1 =3X8 L N — K J =3X6(A1) 20'8" 5'8" 13'4" 10'8" 5'4" 7'10" T10" 8' 1 + 10'8" + 16' 23"0" 31'8" 39'8" Loading Criteria (psq Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.043 M 999 360 B 840 / 395 / 549 / - / 257 18.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.128 M 999 240 N* 315 / 141 / 160 / - / - / 68.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.015 J - - H 585 / 240 / 435 / - / - / 8.0 Des Ld: 37.00 EXP' C HORZ(TL): 0.028 J Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 B Min Brg Width Req = 1.5 P , Soffit: 0.00 BCDL: 5.0 psi N Min Br Width Re Bldg Code: FBC 6th ed 201 Max TC CSI: 0.957 g q = - Load Duration: 1.25 MWFRS Parallel Dist: 0 to h!2 TPI Std: 2014 Max BC CSI: 0.693 H Min Brg Width Req = 1 d Bearings B, N, & H are a rigid surface. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.546 Bearings B, N, & H require a seat plate. Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) GCp!: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.02A.1213.21 Maximum Top Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Chords Tens. Comp. Value Set: 13B (Effective 6/1/2013) B - C 844 -1265 E - F 541 -628 Top chord 2x4 SP #2 N :T3 2x4 SP #1: C - D 676 -932 F - G 648 -274 :T4 2x4 SP 2400f-2.0E: D - E 709 -911 G - H 258 -611 Bot chord 2x4 SP #2 N :B1 2x4 SP #1: Webs 2x4 SP #3 :W7 2x4 SP #2 N: Maximum Bot Chord Forces Per Ply (Ibs) Lumber value set "13B" uses design values Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC B - M 1088 - 604 K - J 924 -159 Bracing M - L 931 -462 J - H 455 -78 (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun Maximum Web Forces Per Ply (Ibs) naiis(0.113"x2.5",min.). Restraint material to be Webs Tens.Comp. Webs Tens. Comp. supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR D - M 619 -431 F - K 876 -1254 tttlnnttsfjhr�rrj E - L 354 -564 K - G 655 -1043 restraint. substitute (1) scab for (1) CLR and (2) ,� ry R r`�i L - F 903 -493 scabs for (2) CLR'S where shown. Scab , ¢� +++°a+.a reinforcement to be same size, species, grade, andea�`(j� 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. ®° + e s� Plating Notes +° $ � Q, 70$ i All plates are 5X5 except as noted. a Wind ° ° Q Wind loads based on MWFRS with additional C&C member design. .r+ +a' C0A�1Hp�1�ro aarHeto+itK+�1'��` 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper y i _ attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, 87 or as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to , drawings 160A-Z for standard plate positions. ALPINE �LPP�I NN Alpine, a division of ITW Buildin Components Group Inc. truss in conformance with ANSI /l PI 1, for handling, shall not be responsible for any deviation from this drawing,any failure to build the ,wowcoWAW installation bracing trussesA this drawing or shipping, and of seal on or cover page , , 13723 Riverport Drive listing this drawing indicates acceptance of professional" engineering responsibility solely for the design shown. The suitability this drawing for is p the Designer ANSI/TPI 1 Sec.2; Suite 200 and use of any structure e responsibility of building per For more information see this mob's general notes page and these web sites: ALPINE: www.al ineitw.wm; TPI: www.t inst.or ; SBCA: www.sbcindusl .corn; ICC: —.i=afe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 2 SEON: 101772/ T12 / HIPS Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E City: 1 FROM: JRH DrwNo: 239.20.1108.34604 Truss Label: A14G FV / WHK 08/26/2020 2 Complete Trusses Required 7' 17' 22'8" 32,8" 39'8" r 7, 10, i + 10, + 7 =6X6 12 C =8X8 =8X8 T2 D T3 E =6X6 T4 F T 6 T U) 0 Z�) B %Z!t&Z G v 1 sa A H =4X6(A1) -8X8 =8X8 -8X8 =4X6(A1) 1 39'8" �1'+ 10' + 910" I 910" + 10 1 10' 19,10" 29'8" 3918" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.295 J 999 360 B 3135 / 1427 / - / - / - / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.816 J 850 240 G 3136 / 1428 / - / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - Wind reactions based on MWFRS EXP: C Des 00 HORZ TL 0.121 1 ( ) B Min Br Width Req = 1.8 g Mean Height: 15.00 ft NCBCLL: 00.0.00 TCDL: 4.2 psf p Code / Misc Criteria Creep Factor: 2.0 G Min Brg Width Req = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.676 Bearings B & G are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.507 Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 It Rep Factors Used: No Max Web CSI: 0.760 Members not listed have forces less than 375# Loc. from endwall: NA FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Camp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 B - C 1424 - 3094 E - F 1534 - 3602 Lumber C - D 1533 -3601 F - G 1425 -3094 Value Set: 13B (Effective 6/1/2013) D - E 2128 -4831 Top chord 2x4 SP #2 N :T2, T4 2x6 SP SS: :T3 2x6 SP #2 N: Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x6 SP SS Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP #3 Lumber value set "13B" uses design values B - K 2752 -1257 J -1 4769 -2187 approved 1/30/2013 by ALSO K - J 4768 -2187 I - G 2753 -1258 Nailnote Maximum Web Forces Per Ply (Ibs) Nail Schedule:0.128"x3" nails Webs Tens.Comp. Webs Tens. Comp. Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. C - K 1287 -417 E - I 727 -1297 Webs : 1 Row @ 4" o.c. K - D 727 -1298 I - F 1287 - 417 Use equal spacing between rows and stagger nails gtnlaittiakaaara arJrtrryrl in each row to avoid splitting. Ld1 Loading {Y ®r.®gigs{eae ,`' #1 hip supports 7-0-0 jacks with no webs. �w` _N +0 Wind Wind loads and reactions based on MWFRS. 0 a°�o.quan t`. COAr�tIIA1. „ 4:lti6a:i9H9&; 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shii ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices pnor to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted he et chord shall have properly attached structural sheathing and bottom chord shall have a progerr y attached ri id ceiling Locations shown for ermanent lateral restraint of webs shall have bracing ins alled per BCSI sections B3, B7 or 610, as applicable. Apply lates to each face ofPtruss and position as shown above and on the Join Details, unless noted otherwise. f�efer to drawings 160A-Z for sandard plate positions. ALPINE Alpine, a division of ITW BuildincLComponents Group Inc., shall not be responsible for any deviation from this drawing,bny failure to build the truss in conformance with ANSI/TPI 1, or for handlin shlppinq, installation and bracing of trussesA seal on this drawing or cover pa listing this drawing indicates acceptance of pro essionar engineering responsibility solely for the design shown, and use of this drawing, for any structure is the responsibility of the Building Designer ANSIITPI 1 Sec.2. , , 13723 Riverport Drive The sui ability Suite 200 per For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wm; TPI: www.t inst.or ; SBCA: www.sbdndust .cam; ICC: wwwJccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7618 / T19 ! COMN Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 ! 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.34838 Truss Label: A15 FV / WHK 08/26/2020 10'8" 15'3"15 23'3"15 3A'8"1 5'7"4 5'0"12 + + 4'7"15 8' 8'4"2 +322�88" 7- 11'15 7' =5X5 D 12 S) 6 2X4 E1F 5X10(S HT P C T3 T4 iZo n (a) MTTV o o B 1 v V) I "I "I T 'A fJ11 3X6(A1) -5X8 =5X5 =4X6 =4X4L =5X5=3X6(At) 21' 5' 13'8" -i �1 8 8 5 5 8' '} 16' 21' 26' 318" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,PI in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.038 0 999 360 B 745 / 341 / 498 / - / 277 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.117 0 999 240 M 1429 /650 /723 /- /- 18.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.017 K - - L 629 / 223 / 242 / - / - / 8.0 EXP: C Des HORZ TL : 0.031 K ( ) 1 534 / 244 / 399 / - / - / 8.0 .00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 Wind reactions based on MWFRS Soffit: 0.00 BCDL: 5.0 sf p Bldg Code: FBC 6th ad 201 Max TC CSI: 0.796 B Min Br Width Re 1.5 9 q = Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.774 M Min Brg Width Req = 1. L Min Brg Width Req = 1.55 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Factors Used: Yes Max Web CSI: 0.703 I Min Brg Width Req = 1.5 Loc. from endwall: Any FT/RT:20(0)/10(0) Bearings B, M. L, & I are a rigid surface. GCpi: 0.18 Plate Type(s): Bearings B, M, L, & I require a seat plate. Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.02A.1213.21 Lumber Members not listed have forces less than 375# Value Set: 13B (Effective 6/1/2013) Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP #2 N :T3, T4 2x4 SP #1: Bot chord 2x4 SP #2 N B - C 1173 -1100 E - F 800 - 686 Webs 2x4SP#3 C-D 1078 -901 G-H 703 -618 Lumber value set "1313" uses design values D - E 886 -674 H - 1 605 -577 approved 1/30/2013 by ALSC Bracing Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SR6 or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun B - O 936 -830 M - L 540 -410 nails(0.113"x2.5",min.). Restraint material to be O - N 570 -428 L - K 530 -366 supplied and attached at both ends to a suitable N - M 598 -426 K - 1 451 -354 support by erection contractor. used in d lieu ofCLR r scab reinforcement f b(1) CLR restra pmi' Forces Per (IbTens. Webs u restraint. substitute (1) scab ane scabs for (2) CLR'S where shown. Scab , yxgtt��utotill,e°: 1,f� (H Tens.Comp.eb Webs Comp. reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" guns �a 080°004W." �° '� o• C - O 458 -291 M - F 773 -732 nails @ 6" oc. i "1,� •, O - D 469 -432 L - G 886 898 ; ¢�• E - M 1630 -1574 £ + Wind nn Wind loads based on MWFRS with additional C&C o member design. S — y �4411ifi �y t ¢r ` � p � COA L �eaeAL 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin sh! Component Safety � ping, installingand bracing. Refer to and follow the latest edition of BCSI (Building Information, byy TPI an SBCA) for satPety practices prior to performing these functions. Installers shall provide temporarryY bracing per BCSI. Unless noted dtherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracingq ins ailed per BCSI sections B3, B7 or 810, Apply lates to face kefer as applicable. each of truss and position drawings 160A-Z for s�andard plate positions. as shown above and on the Join Details, unless noted otherwise. to ALPINE Alpine, a division of ITW Buildin$4Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the µ,,,�,ro,,,,�,„ truss in conformance with ANSI PI 1, or for handlin, shipping, installation and bracing of trussesA seal on this drawing or cover e listing this drawing indicates acceptance of pro essiona engineering responsibility solely for the design shown. and use this drawing for is the the Designer pa _ , 13723 Rive ort Drive The suit9ability rP Suite 200 of any structure responsibility of Building per ANSIITPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: w .al ineitw.wrn: TPI: www.t inst.or ; SBCA: w .sbcindust .cam; ICC: w Jccsafe.orq Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7619 / T18 / SPEC Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.35805 Truss Label: A16 FV / WHK 08/26/2020 { 25'3"15 1915 5'74 , 108 + 17'3"15 + 19'3 15213i15 23'61 273115 29-8' 32'8" 39'8" 5'7"4 5'0'12 6'7'15 2' 2' 2'2"1 2' 2'4"2 2'11"1 7' =5X5 D T6 �2 =5L5 c� C =8X8 =8X8 ;5X10(SRKS co E F G H I J n B Z AB AE M 22 A Y X W V I—lU T S R Q P O =3X6(A1) -5X5 =5X5 =4X4 1112)4(**1 =5X5 3X6(A7) =4XX4 21' 13'8" �1 8 8 13"15 H 1 8i1�T 2 "1s 2� 9 +1d 8' 16' 17' "152, 21 1�3'31525'31�85,1' 27'3"15�2,2"� 31'8 39'8" 9 3' 15 A'3"15 26' ' 29'6"5 Loading Criteria (psp Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psi Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "'I 3B" uses design values approved 1/30/2013 by ALSC Plating Notes All plates are 2X4 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Wind Wind loads based on MWFRS with additional C&C member design. Laterally brace chord above/below filler at 24" OC (or as designed) including a lateral brace on chord directly above/ below both ends of filler (if no rigid diaphragm exists at that point) Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed 201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.037 Y 999' 360 VERT(TL): 0.112 Y 999 240 HORZ(LL): 0.016 O - - HORZ(TL): 0.030 O Creep Factor: 2.0 Max TC CSI: 0.931 Max BC CSI: 0.771 Max Web CSI: 0.571 VIEW Ver: 17.02.02A.1213.21 }� 1 0/1 ��440 r M 0 � o •7 Pti 1 v e 08/26/2020 N T M �I ll w ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 774 / 354 / 508 / - / 317 / 8.0 U 1323 / 588 / 635 / - / - / 8.0 R 711 /237 /257 /- /- /8.0 M 531 /246 /381 /- /- 18.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 U Min Brg Width Req = 1.8 R Min Brg Width Req = 1.5 M Min Brg Width Req = 1.5 Bearings B, U, R, & M are a rigid surface. Bearings B, U, R, & M require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-C 1167-1151 F-G 823 -821 C - D 1085 - 960 G - H 834 - 831 D - E 849 - 722 K - L 728 - 548 E - F 823 - 821 L - M 667 - 571 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - Y 978 - 866 T - S 662 - 551 Y - X 627 - 443 S - R 661 - 551 X - W 462 - 353 R - Q 424 - 375 W - V 462 - 353 Q - P 424 - 375 V - U 462 - 353 P - O 424 - 377 U - T 663 - 550 O - M 445 - 407 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - Y 407 -257 U -AB 548 -605 Y - D 453 - 347 AB- H 472 - 522 E - Z 1577 -1447 R -AE 959 - 847 Z - U 1591 -1466 AE- K 943 - 826 -WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI anc7 SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSL Unless noted ovherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached riqid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face oftrussand position as shown above and on the Join Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI/? PI 1, or for handlin shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , 13723 Rive ort Drive listin this drawing indicates acceptance of pro essiona engineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is p e responsibility of the Building Designer per ANSI/TPI 1 Sec.2.. Suite 200 For more intonation see this job's general notes page and these web sites: ALPINE: www.al ineitw.wm; TPI: www.t inst.or ; SBCA: www.sbcindust xom; ICC: ­kCsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7620 / T3 / GABL Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: HMT DrwNo: 239.20.1108.34509 Truss Label: B1GE I FV / WHK 08/26/2020 1 d8" 214" 4,8" ^i-- 2' - i (TYP) =4F4 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP. C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Special Loads —(Lumber Dur.Fac=1.25 / Plate Dur.Fac =1.25) TC: From 96 pif at -1.00 to 96 plf at 22.33 BC: From 20 plf at 0.00 to 20 plf at 21.33 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See DWGS A16015ENC101014 & GBLLETIN1014 for gable wind bracing and other requirements. 21 '4" — 21,4" 21,4" Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (lbs), or *=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udetl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.005 R 999' 360 B* 125 • / 48 / 39 /- / 11 / 256 Lu: NA Cs: NA VERT(TL): 0.017 R 999' 240 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): 0.004 L - - B Min Brg Width Req = - HORZ(TL): 0.006 R Bearing B is a rigid surface. Code / Misc Criteria Creep Factor. 2.0 Bldg Code: FBC 6th ed 201 Max TC CSI: 0.323 Members not listed have forces less than 375# TPI Std: 2014 Max BC CSI: 0.211 Rep Factors Used: Yes Max Web CSI: 0.092 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 17.02.02A.1213.21 H* r S AMrose�a ama_ 1p — r L i a° �l o••aaaera„ �'°sue°°�'��;` � ABT1QlPi1;'� 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in.fabricat!ng, handling, shipping, installing and bracing. _ Refer to and follow the latest el Alpine, a division of truss in conformanc listing this drawinr and use of this 2 For more information see e rl NI 1; or for r acceptance any structure !ral notes oaoe an as on of iaii nave a progeny Ins 87 10, to erwise. efer ALPINE failure to build the 1 or cover pa e n. The suitability 13723 Riverport Drive Suite 200 ry.com; ICC: vrJccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN: 7621 / T1 / GABL Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 1 FROM: RWM DrwNo: 239.20.1108.34526 Truss Label: C1GE FV / WHK 08/26/2020 7' 7' 14' 7' 5. 2' —' (TYP) m04 D 14' t 12 ih a 14' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Deff/CSI Criteria ♦ Maximum Reactions (lbs), or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefi U# Loc R / U / Rw / Rh / RL / W B• 129 / 50 / 40 /- / 12 / 168 TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.007 J 999- 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.021 J 999- 240 Wind reactions based on MWFRS BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL):-0.004 H - - B Min Brg Width Req = - Des Ld: 37.00 EXP: C HORZ(TL): 0.009 H Bearing B is a rigid surface. Code / Misc Criteria NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.psf Creep Factor. 2.0 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.392 Members not listed have forces less than 375# Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.256 Maximum Gable Forces Per Ply (Ibs) Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.135 Gables Tens.Comp. Gables Tens. Comp. C - J 461 -403 H - E 461 -403 Loc. from endwall: Any FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): I VIEW Ver: 17.02.02A.1213.21 Wind Duration: 1.60 WAVE Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Special Loads --(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25) TC: From 96 pit at -1.00 to 96 plf at 15.00 BC: From 20 plf at 0.00 to 20 plf at 14.00 Plating Notes All plates are 2X4 except as noted. yttattntaaar tarar1 Wind,®a �J}7jry�td Wind loads based on MWFRS with additional C&C member design.t y0 Additional Notes �° e See DWGS A16015ENC101014 & GBLLETIN1014 for a° gable wind bracing and other requirements. a p�p .yo, ��7,�Qa��smar•n•m��°,85'�+(`.n `'4"V� COA G 7 ONAAL sattmioll"t 08/26/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, byy TPI ani SBCA) for saty practices pnor to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted ojherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached riqid ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, as applicable. Apply, plates to each face of truss and position as shown above and on the JoinfDetails, unless noted otherwise. kefer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Buildingg Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss In conformance with ANSIlfPI 1, or for handling, shipping, Installation and bracing of trussesA seal on this drawing or cover pa e , , s.,�a„,,,,,,. 13723 Rive ort Drive Ri listing this drawing indicates acceptance of o) essionar engineering responsibility solely for the design shown. The sui�abillty and use of this drawing for any structure is the responsibilityof the building Designer per ANSI/TPI 1 Sec.2. Suite For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.wrn; TPI: www.tpinst.org: SBCA: www.sbcindustry.com; ICC: www iccsafe ora Maryland Heights, MO 6304 SEQN: 1017781 COMN Ply: 1 Job Number: N334501 Cust: R8975 JReL 1WY589750042 T13 1 FROM: JRH Qty: 1 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.36787 Truss Label: DI / YK 08/26/2020 5' 5' =4X4 C 10, 5' 12 6 (�7 B D Cl' A E t—VF 2x4(Al) 1112x4=2X4(A1) 10, 5' 0, Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/detl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.007 F 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.013 F 999' 240 B 434 /- /- /287 /202 /134 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.003 F - - D 434 /- /- /287 /202 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.006 F - - Wind reactions based on MWFRS Mean Height: 15.00 ft 9 NCBCLL: 00 TCDL: 4.2 psf Code / Misc Criteria CreepFactor: 2.0 B Brg Width = 8.0 Min Req = 1.5 . Soffit: 000 BCDL: 5.0 psf Bldg Code: FBC 6th.ed 201 TC CSI: 0.250 Max D Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.264 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: No Max Web CSI: 0.081 Members not listed have forces less than 375# Loc. from endwall: not in 4.50 It FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 358 -494 C - D 359 -494 Value Set: 13B (Effective 6/1/2013) Maximum Bot Chord Forces Per Ply (Ibs) Top chord 2x4 SP #2 N Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP #2 N Webs 2x4 SP #3 B - F 396 -183 F - D 396 -183 Lumber value set "'I3B" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MW FRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 91f�''jf 3p H. a o Z08 9 d . 6 4 Vs, * A% � • t e ��\il {'p •�®m YtlA6so IVS COA 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byv TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI. Unless dtherwise,top have per noted chord shall properly attached structural sheathingg and bottom chord shall have a proLperly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinq ins ailedper BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the JoinCDetails, unless noted otherwise. kefer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Buildinq Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI/TPI 1, or for handlin, shippintq, installation and bracing of trussesA seal on this drawing or cover pa e. , listing this drawing indicates acceptance of pro essrona engineering responsibility solely for the design shown. The suit9abrlrty �a, e,. 6750 Forum Drive and use of this drawing for any structure is pro) responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see this mob's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or ; SBCA: www.sbcindusl .com; ICC: wwwAccsafe.org Orlando FL, 32821 SEQN: 101775 / COMN Ply: 1 Job Number: N334501 I Cust: R 8975 JRef:1 WY589750042 T14 % FROM: JRH Qty: 1 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.36631 Truss Label: D2 / YK 08/26/2020 5' 5' =4X4 C 10, 5' 12 6 u7 M B D A E8'8" F 2X4(A1) 1112X4 = 2X4(A1) t— 10, 6. , i 10. Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.007 F 9991 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.013 F 9991 240 B 434 /- /- /287 /202 1134 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.003 F - - D 434 /- P /287 /202 P EXP: C Kzt NA Des Ld: 37.00 HORZ(TL): 0.006 F - - Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 00 TCDL: 4.2 psf Code / Misc Criteria CreepFactor: 2.0 B Big Width = 8.0 Min Req = 1.5 0. Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.250 D Br Width = 8.0 Min Re 1.5 9 q= Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.264 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: No Max Web CSI: 0.081 Members not listed have forces less than 375# Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 358 - 494 C - D 359 - 494 Value Set: 13B (Effective 6/1/2013) Maximum Bet Chord Forces Per Ply (Ibs) Top chord 2x4 SP #2 N Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP #2 N Webs 2x4 SP #3 B - F 396 -183 F - D 396 -183 Lumber value set "l313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information tom`• a H' rrrr m o S 0summmolivix 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin sh! ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for saety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted dtherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proger/y attachetl ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracin ins jalled per BCSI sections B3, B7 or B10, _ as applicable. Apply lates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE� drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSIfTPI 1, or for handlingq,, shipping, Installation and bracing of trussesA seal on this drawing or cover pa e , , 6750 Forum Drive listing this drawing indicates acceptance of ro�fessional engineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.ai ineitw.wrn; TPI: www.l inst.or ; SBCA: www.sbcindusl .cam; ICC: —Accsafe.org Orlando FL, 32821 SEQN: 101787/ HIPS Ply: 1 Job Number: N334501 Cust: R8975 JRef:1WY589750042 T17 I FROM: JRH Qty: 1 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.36647 Truss Label: D3G / YK 08/26/2020 u M O 4' 3 3' 7' 10, 3' 4' 3' :4X6 =4X6 12 C D 6� T tO B E M ALiF �8'8" H G 1 2X4(A1) 1112X4 1112X4=2X4(A1) 1 3'1"12 3'1 "12 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Special Loads -(Lumber Dur.Fac. 1.25 / Plate Dur.Fac. 1.25) TC: From 56 plf at -1.00 to 56 plf at 3.00 TC: From 28 pif at 3.00 to 28 plf at 7.00 TC: From 56 plf at 7.00 to 56 plf at 11.00 BC: From 20 plf at 0.00 to 20 pif at 3.03 BC: From 10 pif at 3.03 to 10 plf at 6.97 BC: From 20 pif at 6.97 to 20 plf at 10.00 TC: 129 lb Conc. Load at 3.03, 6.97 TC: 65 lb Conc. Load at 5.00 BC: 80 lb Conc. Load at 3.03, 6.97 BC: 52 lb Conc. Load at 5.00 Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information 10, 3'8"8 3'1 "12 1 6'10"4 10, Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.022 H 999 360 Loc R+ / R- / Rh / Rw / U / RL B 625 P /- P /312 P Lu: NA Cs: NA VERT(CL): 0.044 H 999 240 Snow Duration: NA HORZ(LL): 0.008 C - - E 625 P /- P /312 P HORZ(TL): 0.016 C Creep Factor. 2.0 Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 Code / Misc Criteria Bldg Code: FBC 61h.ed 201 Max TC CSI: 0.288 E Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.379 Bearings B & E are a rigid surface. Rep Fac: No Max Web CSI: 0.059 Bearings B & E require a seat plate. FT/RT:20(0)/10(0) Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 18.02.01A.0205.19 B - C 456 - 963 D - E 456 - 963 WAVE C - D 381 -842 t14 o as i a Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 829 - 384 G - E 829 - 384 H - G 842 -381 �� qos+"•orrr�oiao•sso® ``�"iJ� COA 5 ®OVAL Aunewl 08/26/2020 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a pro erly attached rigid ceiling Locations shown fortpermanent lateral restraint of webs shall have bracingq !nslalled per BCSI sections B3, B7 or �10, as applicable. Apply, plates to each face, o truss and position as shown above and on the JoinCDetails, unless noted otherwise. Nefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSIII PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa e 6750 Forum Drive listing this drawing indicates acceptance of pro�fessionat engineering responsibility solely for the design shown. The suit9abtllty Suite For and use of this drawing, for any structure is p e responsibility of the Building Designer per ANSI/TPI 1 Sec.2.305 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wm; TPI_ www.tpinst.org; SBCA: www.sbcinduslry.com; ICC: w Jcmafe.org Orlando FL, 32821 4 4 SEON: 285011 VAL Ply: 1 Job Number: N334501 Cust: R8975 JRef; 1 WY589750042 T33 FROM: RWM Oty: 1 7A5/320 ,l82EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.35897 Truss Label: V8 �YK / WHK 08/26/2020 3'11"8 7-11" 3'11"8 13'11"8 =4X4 12 B T 6� N---A4X4(D1) �--4M(�Dl)C Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 It GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information See DWG VAL160101014 for valley details. Valley truss connection to truss below shall be designed and furnished by others . 7-11" 7-11" 7'11" Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): 0.028 999 360 Lu: NA Cs: NA VERT(CL): 0.051 999 240 Snow Duration: NA HORZ(LL): -0.010 - - HORZ(TL): 0.019 Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th.ed 2017 Max TC CSI: 0.312 TPI Std: 2014 Max BC CSI: 0.381 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 18.02.01A.0205.19 0 �9'6"3 ♦ Maximum Reactions (lbs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D* 75 /- /- /34 /28 /8 Wind reactions based on MWFRS D Brg Width = 95.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 399 - 366 B - C 399 - 366 o.7Q8 1 • a COA �y ON pe"r'°tw ON FRO 0111t41�4 (3/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an [7 SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a pro erly attached ri id ceiling Locations shown forermanent lateral restraint of webs shall have bracingg ins ailed per BCSI sections 63, B7 or �10, �� as applicabgle. Apply plates to each face o truss and position as shown above and on the Joint" Details, unless noted otherwise. f2efer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the *"m ee,,,,,", truss in conformance with ANSIl1 PI 1, or for handl% shipping, installation and bracing of trussesA seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of ppro essiona engineering responsibility solely for the design shown. The suit9ability and use of this drawing for any structure is go) responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.ai ineitw.com; TPI: www.t inst.or ; SBCA: www.sbcindust .cam; ICC: w Jccsafe.org Orlando FL, 32821 SEQN: 28502/ VAL Ply: 1 Job Number: N334501 Cust: R8975 JRef:1WY589750042 T16 % FROM: RWM Qty: 1 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.35867 Truss Label: V4 YK / WHK 08/26/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 It Loc. from endwall: not in 9.00 ft GCp!: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "13B" uses design values approved 1/30/2013 by ALSC 111"8 3'11" 111 "8 1111,18 12 6 =4X4 B A4X4(D1)=4X4(D1) C 10'6"3 D 1, 3'11" 3-11" 3'11" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell U# Pf: NA Ce: NA VERT(LL): 0.004 9991360 Lu: NA Cs: NA VERT(CL): 0.007 999 240 Snow Duration: NA HORZ(LL): -0.001 - - HORZ(TL): 0.003 Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th.ed 201 7Max TC CSI: 0.070 TPI Std: 2014 Max BC CSI: 0.104 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 18.02.01A.0205.19 WAVE Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information See DWG VAL160101014 for valley details. Valley truss connection to truss below shall be designed and furnished by others. ttUttettttaasatri,Fr +gip frfb� 'it' �yoiantaaa �r�°°r it a a a a a p� a Q. iJ43 m � b i t i 9 i — ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D* 75 /- /- /31 /22 /6 Wind reactions based on MWFRS D Brg Width = 47.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# 08/26/2020 -WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI an � SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporarryY BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly iiid ceilingq Locations shown for ermanent lateral restraint of webs shall have bracin ins�alled per BCSI sections B3, B7 or B10, -Z Apply plates to each face oftrussand position as shown above and on the Joint9Details, unless noted otherwise. f7efer to of I m 1, or Tor nanaiinqq' Snlpp acceptance of ro�fessior any structure is the respon ral notes aaae and these web sites: from this drawingany failure to build the seal on this drawing or cover pa e _for the design shown. The su!>9ability ALPINE .—C w­ 6750 Forum Drive Suite 305 Orlando FL, 32821 • Job Number: N334501 Ply: 1 SEQN: 101767/ T15 / EJAC Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E City: 8 FROM: JRH DrwNo: 239.20.1108.35852 Truss Label: EJ7 KD / WHK 08/26/2020 C 12'2"11 12 6 m o_ to � M d' B 3 A 8'8" D Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP. C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "13B" uses design values approved 1 /30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 7, i Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.017 D HORZ(TL): 0.031 D Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.713 TPI Std: 2014 Max BC CSI: 0.527 Rep Factors Used: No Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 17.02.02C.0211.16 WAVE ��9ffiffi. Wffi A@pp+ o. �',08 9 s .� a • i ffi COAsR�i1. a, 08/26/2020 "WARNING`" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS ♦ Maximum Reactions (lbs) Loc R /U /Rw /Rh /RL /W B 331 / 117 / 259 /- / 173 / 8.0 D 127 /20 /101 /- /- /1.5 C 171 /133 /91 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# quire extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro pperly id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10. i a. Apply plates to each face of truss and position as shown above and on the Joint -Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. a division of nice Wlm ANZ51/ 1 1`1 1, or Tor nanounq, s ing indicates acceptance of role: drawing for any structure is tphe re: see this job's general notes page and these web his drawing,any failure to build the on this drawing or cover page ie design shown. The suitability AL NE AN C­ 6750 Forum Drive Suite 305 Orlando FL, 32821 Job Number: N334501 Ply: 1 SEQN: 101770 / T11 / EJAC Cust: R8975 JRef. 1 WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 6 FROM: JRH DrwNo: 239.20.1108.35804 Truss Label: EJ7A KM / DF 08/26/2020 T. Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MW FRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 It Loc. from endwall: not in 4.50 ft GCp!: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MW FRS with additional C&C member design. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. B 7, 7' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.018 C HORZ(TL): 0.033 C Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th.ed 201 7Max TC CSI: 0.725 TPI Sid: 2014 Max BC CSI: 0.533 Rep Factors Used: No Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 17.02.02C.0211.16 H. frf�d Ak • o. 7,08 1 0 � 0 r r s r COA 08/26/2020 ♦ Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W A 270 / 79 / 188 / - / 151 / 8.0 C 128 /21 /104 /- /- /1.5 B 174 /135 /95 /- /- /1.5 Wind reactions based on MWFRS A Min Brg Width Req = 1.5 C Min Brg Width Req = - B Min Brg Width Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety. Information, byy TPI ant SBCA) fo'r saty practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathingq and bottom chord shall have a propperly attached timid ceilin Locations shown forpermanent lateral restraint of webs shall have bracmq inslalled per BCSI sections B3, B7 or 810, as applicable. Apply plates to each face of truss and position as shown above and on the Joinf9Deta,Is, unless noted otherwise. f7efer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ,.,,,,.�,.,,,,,„ truss in conformance with ANSI/l PI 1, or for handlingq,, shippin , installation and bracing of trussesA seal on this drawing or cover, e , , 6750 Forum Drive listing this drawing, indicates acceptance of pprofessional engineering responsibility solely for the design shown. The su!t9ability and use of this drawing for any structure is go), responsibility of the building Designer per ANSI/TPI 1 Sec.2. Suite 305 For more information see this job's general notes page and these web sites: ALPINE: www.alpineiha.com; TPI: www.tpinst.or : SBCA: www.sbclhdus".com; ICC: w Jccsafe.org Orlando FL, 32821 s SEQN: 101539/ EJAC Ply: 1 Job Number: N334501 Cust: R8975 JRef:1WY589750042 T28 I FROM: JRH Qty: 3 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E Dnallo: 239.20.1108.35945 Truss Label: EJ3 I / YK 08/26/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " V 2X4(A1) Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "136" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. I ce) 0 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(CL): NA Snow Duration: NA HORZ(LL): 0.001 D HORZ(TL): 0.002 D Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th.ed 2017 Max TC CSI: 0.216 TPI Std: 2014 Max BC CSI: 0.123 Rep Fac: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 18.02.01A.0205.19 .40 40 e° Q. 708 1 •04 9 � r,t V -°� COA Q7§1 "rtitAL 08/26/2020 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 188 P /- /162 /76 /86 D 52 /- /- /41 /6 !- C 65 /- /- 131 /51 !- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING'* READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI an SBCA) for saety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properly ,iid ceiling Locations shown for permanent lateral restraint of webs shall have bracing insalled per BCSI sections B3, B7 or 810, i e. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. Of 'im 1, or Torn acce tance any sFructure his drawing,any failure to build the on this drawing or cover page ie design shown. The sui gabdtty TPI: w Jpinst.org; SBCA: ALPINE u+mvC m _ 6750 Forum Drive Suite 305 Orlando FL, 32821 Job Number: N334501 Ply: 1 SEON: 7622 / T35 / JACK Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E City: 4 FROM: RWM DiwNo: 239.20.1418.53201 Truss Label: CJ5 KD / WHK 08/26/2020 C 12 6 M CV M B CM 1 A D 1, 4'11"4 I 4' 11 "4 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/# Loc R / U / Rw / Rh / RL / W B 256 195 / 207 / - / 128 / 8.0 TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): NA D 89 / 13 / 68 / - / - / 1.5 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.005 D C 118 / 92 / 61 / - / - / 1.5 Des Ld: 37.00 EXP: C HORZ( TL ) 0.010 D - Wind reactions based on MWFRS Code / Misc Criteria NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 B Min Brg Width Req = 1.5 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed 201 Max TC CSI: 0.411 � D Min Brg Width Req = - Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.254 i C Min Brg Width Req = - Bearing B is a rigid surface. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.000 i Bearing B requires a seat plate. Loc. from endwall: not in 4.50 it FT/RT:20(0)/10(0) GCp!: 0.18 Plate Type(s): Members not listed have forces less than 375# VIEW Ver: 17.02.02A.1213.21 Wind Duration: 1.60 WAVE Lumber Value Set: 13B (Effective 6/112013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. f�srf� g aqs ����samnse ,,aa o.7.08 1 win g S AST 0 @�awaftort9®y 4 r}\ COA ON AAL (9/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS; Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI anr7 $BCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathinp and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join�Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW BuiidingComponents Group Inc. shall not be responsible for any deviation from this drawing;any failure to build the truss in ANSI 1, for .n CMP",. conformance with or handlin), shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , listing this drawing indicates acceptance of to�fessionar engineering responsibility solely for the design shown. The suiFabtllty and use of this yawing for any structure is the responsibility the Building Designer ANSI/TPI 1 Sec.2. 13723 River ort Drive p Suite 200 of per For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.wm; TPI: www.t inst.or ; SBCA: www.sbcindust .com; ICC: www.iccsafe.org Maryland Heights, MO 6304 Job Number: N334501 Ply: 1 SEQN:7623 / T34 /JACK I Cust:R8975 JRef: 1WY589750042 ,7A5/320,182EC,E,02G,RH01 / 1828/CALI/4EBB ELEV.C,E Qty: 4 FROM:RWM DrwNo: 239.20.1108.35728 Truss Label: CJ3 FV ! WHK 08/26/2020 �— 1' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. C T 2' 11 "4 2' 11 "4 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W B 185 / 75 / 160 / - / 84 / 8.0 Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA D 50 16 / 41 / - / - / 1.5 Snow Duration: NA HORZ(LL): 0.001 D C 63 / 50 / 29 /- /- / 1.5 HORZ(TL): 0.001 D Creep Factor: 2.0 Wind reactions based on MWFRS B Min Bing Width Req = 1.5 Code / Misc Criteria Bldg Code: FBC 6th ed 2017 Max TC CSI: 0.206 D Min Brg Width Req = - TPI Std: 2014 Max BC CSI: 0.115 C Min Brg Width Req = - Rep Factors Used: Yes Max Web CSI: 0.000 Bearing B is a rigid surface. Bearing B requires a seat plate. FT/RT:20(0)/10(0) Plate Type(s): Members not listed have forces less than 375# VIEW Ver: 17.02.02A.1213.21 WAVE +9`m'�`��f• (l • ,ref r��r s g COA sun "I ' 08/26/,' **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing. and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI an SBCA) for sa ety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted dtherwise,top chord shall have properly attached structural sheathinq and bottom chord shall have a pro perr y attached ri id ceiling Locations shown forpermanent lateral restraint of webs shall have bracin insTalled per BCSI sections B3, B7 or B10, as appiicab�e. AppTy lates to each face ofptruss and position as shown above and on the Joint9Details, unless noted otherwise. kefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the u„ wco�,,,n,. truss in conformance with ANSIf PI 1, or for handlingq'' shippin , Installation and bracing of trussesA seal on this drawing or coverpa , 13723 Riverport Drive listing this drawing indicates acceptance of pro) essional engineering responsibility solely for the design shown. The s.1 bdtty, and use of this drawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. Suite 200 For more information see this job's general notes page and these web sites: ALPINE: www.al ineiiw.mm: TPI: www.t inst.or ; SBCA: www.sbcindust .corn; ICC: w Jccsafe.orq Maryland Heights, MO 6304 U SEQN: 101784/ JACK Ply: 1 Job Number: N334501 Cust:R8975 JRef:1WY589750042 T32 /I FROM: RWM Qty: 4 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.35960 Truss Label: CJ1 / YK 08/26/2020 4 3 i 12 6 C �— 1' Loading Criteria (psf) Wind Criteria TOLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA D Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 It Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. _F T /-� 9'2"5 11 "4 11 "4 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(CL): NA Snow Duration: NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Code / Misc Criteria Creep Factor. 2.0 Bldg Code: FBC 6th.ed 2017 Max TC CSI: 0.196 TPI Sid: 2014 Max BC CSI: 0.025 Rep Fac: No Max Web CSI: 0.000 FT/RT:20(0)/l0(0) Plate Type(s): WAVE VIEW Ver: 18.02.01A.0205.19 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /148 /79 /41 D 11 /-2 /- /18 /12 /- C - /-15 /- /27 132 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# COAly A ILL s� mens" 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI. Unless have bottom have per noted ovherwise,top chord shall properly attached structural sheathing and chord shall a properly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin Ins ailed per BCSI sections B3, B7 or 810, as applicable. Apply to face truss the Joinf Details, kefer to plates each of and position as shown above and on unless noted otherwise. drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in 1, for •um comvur conformance with ANSIrrPI or handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , Iisting this drawing indicates acceptance of pro esslona engineerin responslb!Itty solely for the design shown. The su! ability building 6750 Forum Drive Suite 305 and use of this drawing for any structure is [he responsibility of the Designer per ANSI/TPI 1 Sec.2: For more information see this job's general notes page and these web sites: ALPINE: www.al ineirtv.wm: TPI: www.tpinst.org; SBCA: www.sbcinduslgxom; ICC: w Jccsafe.org Orlando FL, 32821 SEQN: 101781 / JACK Ply: 1 Job Number: N334501 Cust: R8975 JRef: 1 WY589750042 T27 FROM: RWM City: 4 7A5/320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.36054 Truss Label: CAA / YK 08/26/2020 12 6 C 43 V T 3 9'2"5 M' 8rOn 11,114 1, 11 114 Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in Ioc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- 1148 /79 /41 BOLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): NA BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): -0.000 D D 11 /-2 A /18 /12 /- Des Ld: 37.00 EXP: C Kzt NA HORZ(TL): 0.000 D - - C - /-15 /- /27 /32 /- Code / Misc Criteria NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: Height: psi Creep Factor: 2.0 Wind reactions based on MWFRS Soffit: 0.00 BCDL: 5.0 sf p Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.196 i B Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 : TPI Std2014 Max BC CSI: 0.025 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Spacing: 24.0 " C&C Dist a: 3.00 it Rep Fac: No Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: Any FT/RT:20(0)/10(0) Bearing B requires a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. • truss it listing and u For morc v+• Hl r e m o,08 q ¢'y pp p• f ZAT W0`-,T f COALkONAL ttt 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS; s require extreme care in fabricating, handlin shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporarryy c�er BCSI. Unless noted oTherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly r! id ce!I!n Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, icab9e. Apply plates to each face oftrussand position as shown above and on the Joinf9Details, unless noted otherwise. kefer to ALPINE Is 160A-Z for standard plate positions. a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the nN wconw�rm conformance with ANSI fI PI 1, or for handlin shipping, installation and bracing of trussesA seal on this drawing or cover page , , 6750 Forum Drive this drawing indicates acceptance of pro esslona engineering responsibility solely for the design shown. The suitability Suite 305 ce of this yawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2: information see this lob's general notes page and these web sites: ALPINE: www.alpineitw.wrn; TPI: www.tpinsl.ora' sack www.sbcindustrycorn; ICC: www.iccsafe.org Orlando FL, 32821 v. ° Job Number: N334501 Ply: 1 SEQN: t626 / T26 / HIP_ Cust: R8975 JRef: 1WY589750042 ,7A5/320 ,182EC,E ,02G ,RH01 /1828/CALI/4EBB ELEV.C,E Qty: 2 FROM: RWM DrwNo: 239.20.1108.33979 Truss Label: HJ7 TCE / WHK 08/26/2020 5'3"5 9110"1 5'3"5 4'6"11 T 1 / [7 9'2„2 9'2"2 17„'1 1 9'1011 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.040 F 9991 360 B 326 / 154 / - /- /- / 10.6 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.111 F 999 240 E 364 / 84 / - / 0 / 0 / 1.5 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.010 C - - D 214 1177 /- /- /- / 1.5 Des Ld: 37.00 EXP: CMean HORZ(TL): 0.018 C - - Wind reactions based on MWFRS Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 B Min Brg Width Req = 1.5 Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.546 E Min Br Width Re g q = - Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Sid: 2014 Max BC CSI: 0.416 D Min Brg Width Req = Bearing B is a rigid surface.. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: No Max Web CSI: 0.260 Bearing B requires a seat plate. Loc. from endwall: NA FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1115.21 Maximum Top Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Value Set: 13B (Effective 6/1/2013) B - C 394 -562 Top chord 2x4 SP #2 N Bat chord 2x4 SP 2400f-2.OE Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 Chords Tens.Comp. Lumber value set "1313" uses design values approved 1/30/2013 by ALSC B - F 531 -358 Loading Maximum Web Forces Per Ply (Ibs) Hipjack supports 6-11-8 setback jacks with no webs. Webs Tens.Comp. Wind C - F 394 -593 Wind loads and reactions based on MWFRS. Provide (3) 0.162"x3.5", min toe -nails at top chord. gttttssrtltsgjf#lr Provide (3) 0.162"x3.5", min toe -nails at bottom chord. 5tv • ,�g7tprr�/P/.� v^ q° y ° ° 0NA1. COA ftefv, 08/26/2020 "WARNING•` READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT'• FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary) bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper y attached rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections 63, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE drawings 16OA-Z for standard plate positions. Alpine, a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the .N wCwwAn. truss in conformance with ANSI/TPI PI 1, or for handling{ shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , 2400 Lake Orange Dr. listing this drawing indicates acceptance of pro esslona engineerinq responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.mm; TPI: www.l inst.or ; SBCA: www.sbdndusl .com; ICC: -imsafe.org Orlando FL, 32837 t SEQN: 101537/ HIP_ Piy: 1 Job Number: N334501 Cust: R8975 JRef: 1WY589750042 129 FROM: JRH Qty: 2 7A51320 ,182EC,E ,02G ,RH01 / 1828/CALI/4EBB ELEV.C,E DrwNo: 239.20.1108.35975 Truss Label: HJ3 / WHK 08/26/2020 T Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " �--- VY Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/112013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "13B" uses design values approved 1/3012013 by ALSC Loading Hipjack supports 2-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Additional Notes Refer to General Notes for additional information Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 1i 4'2"3 4'2113 C Snow Criteria (Pg,Pf in PSF) Def /CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA 10'2"6 CM N 8'8n ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL Lu: NA Cs: NA VERT(CL): NA B 84 A A A /45 /- Snow Duration: NA HORZ(LL): 0.001 D D 28 /- A /7/- HORZ(TL): 0.002 D C 64 A /- /- /48 /- Code / Mist; Criteria Creep Factor: 2.0 Wind reactions based on MWFRS Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.120 B Brg Width = 10.6 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.074 D Brg Width = 1.5 Min Req = - Rep R Rep Fac: No Max Web CSI: 0.000 C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. 10(0) FT/Bearing B requires a seat plate. Plate Type(s): Members not listed have forces less than 375# WAVE VIEW Ver. 18.02.01A.0205.19 4 ,,ggyp'.p r • f': rI • a 1�, � p • �q py (� q v e • a v ••• �� 4•••"Sa{e�r�rj�ravrrsle {�,y.\�gy-;.4�^g" COA �t1&dlrygiiiN�p 08/26/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building quire Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly qid ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or 610, le._ AppTy plates to each face oftrussand position as shown above and on the JoinrDetails, unless noted otherwise. kefer to Alpine, a division of truss in conformanc listing this drawinc and use of this i For more information see rl F'I 1; or Tor n acceptance any structure ire to build the cover pa e The suitability ALPINE *vmvcomv*rn 6750 Forum Drive Suite 305 Orlando FL, 32821 r Gable Stud Reinforcement Detail ASCE 7-101 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Orr 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Orr 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Orr 120 mph Wind Speed, 15' Mean Heloht. Partially Enclosed, Exposure D. Kzt = 1.00 S 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) lx4 'L' Brace r (1) 2x4 'L' Brace ■ (2) 2x4 'L' Brace ww (1) 2x6 'L' Brace 1( (2) 2x6 'L' Brace No Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B f r #1 / #2 3' 10' 6' 7' 6' 10' 7' 9' e' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' U S P r E #3 3' 8' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' Stud 3' 8' 5' 9' 6' 1' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' O r Standard 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' 11' 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' #1 4' 0' 6' B. 6' 11' 7' 10' 8' 2' 9' 4' 9' 8' 12' 4' 12' 9' 14' 0' 14' 0' _j S P #2 3' 10, 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12' B' 14' 0' 14' 0' (U D P L #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, ill 11' 8' 14' 0' 14' 0' Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, ill Ill 8' 14' 0' 14' 0' d Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U #1 / #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' Ill 0' 13' 11' 14' 0' 14' 0' 14' 0' .- S P P #3 4' 2' 7' V 7' 9' 8' 9' 9' 1' 10' 5' 10, 10' 13' 9' 14' 0' 14' 0' 14' 0' U u P Stud 4' 2' 7' V 7' 6' 8' 9' 9' 1' 10' 5' 10' 10' 13' 9' 14' 0' 14' D' 14' 0' O Hl Standard 4' 2' 6' 1' 6' 5' 8' 1' 8' 8' 10' 5' 10, 10' 12' 8' 13' 7' 14' 0' 14' 0' #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10' 8' I1' 1' 14' 0' 14' 0' 14' 0' 14' 0' S P 42 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13, 11' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10, 6' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' a) D P L Stud 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10, 6' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' Standard 4' 2' 5' 8' 6' 0' 7' 6' 8' 0' 10' 2' 10, 10' 11' 10' 12' 7' 14' 0' 14' 0' #1 / #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 10' 7' 12' 1' 14' 0' 14' 0' Ill ' 14' 0' d S P P #3 4' 7' 8' 2' 8' 5' 9' e' 10' 0' 11' 6' 12' 0' 14' 0' 14' 0 14' 0' 14' 0' LJ U u P Stud 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' O fl Standard 4' 7' 7' 0' 7' 5' 9' 4' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 1' 8' 5' 8' 8' 9' 11' 10' 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3' 8' 7' 9' 9' 10, 2' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' .—i r D r L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 14' 0' 14' 0' 14' 0' Bracing Group Species and Grades, Group At S ruce-Pine-Fir Hen -Fir #1 / 02 ist2ndard 1 1 Studda #3 Stud 13 Stanrd Dou ins Fir -Larch Southern Plnewsm #3 #3 Stud Stud Standard Standard Group Ill Hem -Fir #1 L Btr #1 Douglas Fir-Lorch Southern Plneww■ #1 #1 #2 #2 lx4 Braces shall be SRB (Stress -Rated Board). wwFor lx4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group B values may be used with these nudes. Gable Truss Detail Notes, Wind Load deflection criterion Is L/240. Provide uplift connections for 75 pip over continuous bearing (5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Symm Aboutl Attach 'L' braces with 10d (0.12B'x3.0' min) nails. able Truss )K For (1) 'L' bracer space nalls at 2' o.c. In 18' end zones and 4' o.c, between zones. Diagonal brace option, vertical length may n, )K)KFor (2) 'L' braces, space nulls at 3' ox, In IS' end zones and 6' o,c, between zones. doubled when diagonal brace Is used, Connect 18' L A 'L' bracing must be a minimum of 80% of web member length. diagonal brace for 60011 at each end. Max web - 'L' Brace _� Gable Vertical Plate Sizes total length Is 14'. Vertical Length No Splice 2x6 DF-L #2 or Less than 4' 0' 2X3 Vertical length shown In table above, 41' better diagonal bracer single or double cut (as shown) at upper end, e L Ini X 1 li, q a++]na jr`f'r +' �� �i/ ® asn Greater than 4' 0', but 3X4 less than 11' 6' Greater than 11' 6' 4X4 + Refer to common truss design for I peak, splice, and heel plates, Connect diagonal at midpoint of vertical web, Refer to Sa •• � '� +� �P chart hloveo"for ax abl ye till a lei th, Refer to the Building Designer for conditions ALPINE AN ITW COMPANY 514 Earth City Expressway Suite 242 VARNINGI­ READ AND FOLLOW ALL N13TES ON THIS --IMPORTANT-- FURNISH THIS BRAVING TO ALL CONTRACTORS INCLUDIIG�THE INSTALLERSZ Trusses require extreme core In fabricating, handling, shipping, Installing end bracing. Refe�"4 tadpn$ follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fos tyw practices prior to performing these functlons. Installers shall provide temporary bracing pe BCSI. • Unless noted otherwise, top chord shall have property attached structural sheathing and ba n cho shalt have a properly attached rigid celling. Locations shown for pernanent lateral restraint f 5 shall have bracing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to eo of truss and 1pastmg,'1 n as shown above and on the Joint Dvta lc, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Bullding Components Group Inc. chaff not be responsible for any devlatlo r this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for hontlUnp, shippin Installotlon L bracing of trusses. A seal on this drawing or cover page listing this drawing, indicates acceptance of professional englneering responsibility solely for the design shorn The suitability and use of this drawing for any structure Is the responsibility of the Building Designer per ANSI/TPI 1 SecZ s - p g s C AT • rc! ®H � •� �r ea••s••�, w�••a®a \) 66 Et �!�>1V /'�i. t A' $/26/2020 MAX, TOT. LD, 60 PSF REF ASCE7-10-GAB16015 DATE 10/01/14 DRWG A16015ENC101014 MAX, SPACING 24.0° Earth City, MO 63045 For Fore Information see this ,Job's general notes page and these web sites, ALPINE, ow.alpinettr.comU TPB w..tpinst..rg, SBCAr wnw.sbcindustry,orgl ]CC, www1ccsofenrg 11 t r Gable Stud Reinforcement Detail ASCE 7-101 180 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Or, 160 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1,00 Orr 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 ❑r, 140 moh Wind Soped. 15' Mean Heloht. Partially Fnclnspd. Fxoosurp D. 1<7t = 1.00 S 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) Ix4 'L' Brace Il (1) 2x4 'L' Brace vi (2) 2x4 'L' Brace l[r (1) 2x6 'L' Brace r (2) 2x6 'L' Brace r Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B � #1 / #2 3' 6' 6' 0' 6' 3' 7' 1' 7' 4' B' S' B' 9' 11' 1' 11' 7' 13' 3' 13' 9' U S P F #3 3' 4' 5' 1' 5' 5' G' 9' 7' 3' 8' 4' e' e' 10' 7' 11' 4' 13' 1' 13' 7' l J F Stud 3' 4' 5' 0' 5' 4' 6' 9' 7' 2' B' 4' 8' 8' 10' 6' Ill 3' 13' 1' 13' 7' O Ill Standard 3' 4' 4' 4' 4' 7' 5' 9' 6' 2' 7' 10' 8' 5' 9' 1' 9' 8' 12' 4' 13' 2' #1 3' 8' 6' 1' 6' 4' 7' 2' 7' 5' B' 6' B' 10' 11' 3' I1' 8' 13' 4' 13' 11' J S P #2 3' 6' T 9' 6' 2' 7' 1' 74' 8' 5' 8' 9' 11' 1' 11' 7' 13' 3' 13' 9' #3 3' 5' 4' 7' 4' 10' 6' 1' 6' 6' 8' 2' 8' 9' 9' 6' 10' 2' 12' 11' 13' 8' F Stud 3' 5' 4' 7- 4' 10' 6' 1' 6' 6' 8' 2' 8' 9' 9' 6' 10, 2' 12, Ill 13' 8' d Standard 3' 1' 4' 0' 4' 3' 5' 4' 5' 9' 7' 3' 7' 9' 8' 5' 9' 0' 11' 5' 12, 3' U #1 / #2 4' 0' 6' 10' 7' 2' 8' 1' 8' 5' 9' 8' 10, 1' 12' 9' 1 13' 3' 14' 0' 14' 0' _ S P F #3 3' 10, 6' 2' 7' 2' 8' 0' 8' 4' 9' 7' 9' 11' 12' 7' 13' 1' 14' 0' 14' 0' 0) U o IJ F �I Stud 3' 10' 6' 2' 6' 7' 8' 0' 8' 4' 9' 7' 9' 11' 12' 7' 13' 1' 14' 0' 14' 0' Standard 3' 10' 5' 4' 5' 8' 7' 1' 7' 7' 9' 7' 9' 11' 11' 1' IS' 11' 14' 0' 14' 0' #1 4' 3' 7' 0' 7' 3' 8' 3' 8' 6' 9' 9' 10' 2' 12' 11' 13' 5' 14' 0' 14' 0' P #2 4' 0' 6' 10' 7' 2' 8' 1' 6' 5' 9' 8' 10' 1' 12' 9' 13' 3' 14' 0' 14' 0' #3 3' 11' 5' 7' 5' 11' 7' 5' 7' 11' 9' 7' 10, 0' I1' 8' 12' 6' 14' 0' 14' 0' I D F L Stud 3' 11' 5' 7' S' 11' 7' 5' 7' 11' 9' 7' 10, 0' Ill 8' 12' 6' 14' 0' 14' 0' Standard 3' 9- 4' 11' 5' 3' 6' 7' 7' 0' 8' 11' 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' #1 / #2 4' 5' 7' 7' 7' 10' 8' 11' 9' 3' 9' 8' 11, 1' 14' 0' 14' 0' 14' 0' 14' 0' d S P F #3 4' 3' 7' 2' 7' 7' B' 10' 9' 2' 10, 6' 10, Ill 13' 10' 14' 0' 14' 0' 14' 0' LD U IJ F Stud 4' 3' 7' 1' 7' 7' 8' 10' 9' 2' 10, 6' 10, I1' 13' 10' 14' 0' 14' 0' 14' 0' O Ill Standard 4' 3' 6' 2' 6' 6' B' 2' B' 9' 10' 6' 101 ill 12' 10' 13' 9' 14' 0' 14' 0' X #1 4' 8' 7' 8- 7' 11' 9' 0' 9' 5' 10, 9' 11' 2' 14' 0' 14' 0' 14' 0' 14' 0' d P #2 4' 5' 7' 7' 7' 10' 8' 11' 9' 3' 10, 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10' 8' 7' 9' 12, 10' 7' 11' 0' 13' 5' 14' 0' 14' 0' 14' 0' .--I I D F L Stud 4' 4' 6' S' 6' 10' 8' 7' 9' 12, 10' 7' 11' 0' 13' S' 14' 0' 14' 0' 14' 0' Standard 4' 3' 5' 8' 6' 1' 7' 7' 8' 1' 10' 3' 10' I1' 11' 11' 12' 9' 14' 0' 14' 0' Diagonal brace option, vertical length may be doubled when diagonal brace Is used, Connect diagonal brace for 775# at each end, Max web total length Is 14'. Vertical length shown In table above. Connect diagonal at midpoint of vertical web. ALPINNITWE MPANY 514 Earth City Expressway Suite 242 7 Earth City, MO 63045 2x6 DF-L #2 or better dla ).no, brace) single or double cut (as shown) at upper, end. .l 14N 1_4t Refer to chart --WARNING-- READ AND FOLLUV ALL NOTES ON THIS DRAWING! vI1P12RTANTrr FURNISH THIS DRAWING TO ALL CUNTRACTORS INCLUDING THE INSTALLER' :es require extreme core In fabricating, handling, shipping, Installing and bracing. Refr the latest edition of BCSI (Bulding Component Safety Information, by TPI and SBCA) fc as prior to performing these functions. Installers shall provide temporary bracing p noted otherwise, top chord shall have properly attached structural sheothino and bi nfer to drawings 16CA-Z for standard plate positions. Alpine, division of ITV Building Components Group Inc. shall not be responsible for any devlatk Js drawing, any falwe to build the truss In conformance with ANSI/TPI 1, or for handing, ship; stolloti— 6 bracing of trusses. A sent on this drawing or cover page listing this drawing, Indicates acceptance of professional gineeri g responsib y solely for the des,ggnn shown The suitability and use of tNs drawing Ir any structwe Is the respons6Nty of th r Building Designer per ANSI/TPI 1 Sec2. for more Information see this ,fob's general notes page and these web sites, ALPINE, www.alptneltw.com) TPI, wwwApinst.orgl SBCA, www.sbclndustry.orgJ ICC, wwwJccsmfearg Bracing Group Species and Grades, Group A, S ruce-Pine-Fir Hem -Fir #1 / #2 Istandard1 #2 1 Stud #3 1 1 #3 IStondard Dou Las Fir -Larch Southern Pinerrr #3 #3 Stud Stud Standard Standard Group BI Hem -Fir #1 b Btr #1 Douglas Fir -Larch Southern Pinerrr #11 #1 #2 i 1 #2 Ix4 Braces shall be SRB (Stress -Rated Board). ■rFor Ix4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group H values may be used with these grades. Gable Truss Detail Notes, Wind Load deflection criterion is L/240. Provide uplift connections for 100 plf over continuous bearing (5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang, Attach 'L' braces with 10d (0,128'x3,0' min) nails, )K For (1) 'L' brace, space nails at 2' o.c. In 18' end zones and 4' o.c. between zones. )K)KFor (2) 'L' braces, space nails at 3' ox. In 18' end zones and 6' o.c, between zones. 'L' bracing must be a minimum of 80% of web member length. Gable Vertical Plate Sizes Vertical Lennth I No Splice Less than 4' 0' 2X3 Greater than 4' 0', but I 4X4 less than 10' 0' + Refer to common truss design for peak, splice, and heel plates. Refer to the Building Designer for conditions not addressed by this detail. REF ASCE7-10-13018015 DATE 10/01/14 DRWG A18015ENC101014 MAX, TOT. LD, 60 PSF MAX. SPACING 24.0' 2 'T Relnfon Memb Go Tr Gable Detail Fnr I Pt -in VPrtirnl Gable Truss Plate pproprlate Alpine gable detall for �e sizes for vertical studs, Engineered truss design for peak, rb, and heel plates, vertical plates overlap, use a ite that covers the total area of lapped plates to span the web, e, 2X4 2X4 2XB vrovicie connections for uplift specified on the engineered truss design. Attach each 'T' reinforcing member with End Driven Nallsi IOd Common (0,148'x 3,',min) Nalls at 4' o,c. plus (4) nails In the top and bottom chords, Toenalled Nalls, IOd Common (0,148'x3',min) Toenails at 4' o.c, plus (4) toenails In the top and bottom chords. This detall to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detall. Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 6 ASCE 7-16 Gable Detall Drawings A11515ENC10011B, A12015ENC100118, A14015ENC100118; A16015ENC100118, A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118, A11530ENC100118, A12030ENC100118, A1403OENC100118, A16030ENC100118, A18030ENC100118, A20030ENC100118, A20030END100118, A2003OPED100118, S11515ENC100118, S12015ENC100118, S14015ENC100118, S16015ENC100118, S1BO15ENC100118, S20015ENCI00118, S20015END10011 1 / S11530ENC100118, S1203OENC100118, S14030ENC 30 1001 B�f�R SlB030ENC100118, S20030ENC100118, S20030E 01 wa��Qs I See appropriate Alpine gable detail for maxim yaFgrt2 w 1 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe -nail - Or - End -nail To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detall). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member, Web Length Increase w/ 'T' Brace Examples ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o,c, SP #3 'T' Reinforcing Member Size = "2x4- 'T' Brace Increase (From Above) = 307 = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' 'T' Relnf, Mbr, Size 'T' Increase 2x4 30 2x6 20 nDlPORTANTww FURNNIISHTHISSDDRAAND NG o ALL aV ALL NOTES CONTRACTORS INCIS DRAVINGILUDING THE INSTALLER&,2 ® 0' l V0 l z REF LET -IN VERT Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer ,pne w a follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) fokyAs t)s • °O DATE 01/02/2018 practices prior to performing these functions. Installers shall provide temporary ding peCSI. Untess noted otherwise, top chord shall have properly attached structural sheathing amd bon cha a''e Q w .. DRWG GBLLETIN0118 shall have a properly attached rigid ceiling. Locatlons shown for permanent lateral restrain v shall have bracing Installed per SCSI sections B3, 87 or BIO, as applicable. Apply plotes to ALPINE Re truss and Ipngs1 D as shown above and on the Joint DetnRs, unless noted otherwise. • A% o f Refer to drawings 160A-Z for standard plate positions. UO i e" Alpine, n dNlslon of ITV Building Components Group Inc, shall not be responsible for any devlatb r '�wpw • •�® this drawing, any failure to build the truss In conformance with ANSLTPI 1, or for hantlUng, shippin Oeei1•moa v� MAX, TOT, LD, 60 PSF AN ITW COMPANY Installation L broc f trusses. A seal on this drawing or cover page listing this drawing, Ywlcates acceptance of profassbnnl 514 Earth City Expressway engineering responsmlUty solely for the design shown. The suitability and use of this drawYp ���' • �'^ sunezaz for any =tractors Ic the responsibility of the BuIld1+g Designer per ANSI/TPI 1 Sec.B 9ZIIW ri� 8/2G/2020 DUR, FAC, ANY Earth City, MO 63045 For more Information see this Job's general notes page and these web sltesi MAX, SPACING 24,0' ALPINE, www.aiptneltw.conl TPI- www.tpinst.orgi SBCA, www,sbclndustry.org) ICG wwwJccsafearg e Gable Fnr I Pt -in IT Relnfoi Memb Ga Tr Detail VPrtirnlcz Gable Truss Plate Sizes ppropriate Alpine gable detall for e sizes for vertical studs. Engineered truss design for peak, ,b, and heel plates, vertical plates overlap, use a ate that covers the total area of lapped plates to span the web, el 2*2X4 2X8 rrovlae connections for uplltt specitlecl on the engineered truss design. Attach each 'T' reinforcing member with End Driven Nallsl IOd Common (0,148'x 3',min) Nails at 4' o.c, plus (4) nails In the top and bottom chords, Toenalled Nails, 10d Common (0,148'x3',min) Toenails at 4' o,c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 Gable Detail Drawings - A11515ENC101014, A12015ENC101014, A14015ENC101014, A16015ENC101014-1 A18015ENC161014, A20015ENC101014, A20015END101014, A20015PEDIO1014, A11530ENC101014, A12030ENC101014, A14030ENC101014, A16030ENC101014, A18030ENCI01014, A20030ENC101014, A20D30END101014, A20030PED101014 S11515ENCI00815, S12015ENC100815, S14015ENCI00815, S16015ENC100815, S18015ENC100815, S20015ENC100815, S20015END1008 IMNISr'�Y11Q1}g15, S11530ENC100815, S12030ENC100815, S1403DENC 03� C10�0 { S18030ENC100815, S20030ENC100815, S20030 00 �Qga1b:�D*ai8� See appropriate Alpine gable detall for mnxlr �aRq{2 ,,®qr 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe -nail X- Or - End-nall To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detall). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member, eb Length Increase w/ 'T' Brace Examples ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o,c. SP #3 'T' Reinforcing Member -Size = 2x4 'T' Brace Increase (From Above) = 30% = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' 'T' Relnf, Mbr. Size 'T' Increase 2x4 30 2x6 20 v➢lPORTANT wFWJISH TH S ➢DRAAD AND NG TTa ALL OLLOW coNTR�ACTORI =LLuDiNd THE INSTN_LERS ® AWM U. t uo K REF LET -IN VERT Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer n�, a DATE 10/Ol/14 follow the latest edition of SCSI (Buttding Component Safety Information, by TPI and SBCA) F. s t.4 - P 3 ppractices prior to performing these functions, Installers shall provide Unix, ryy bracing pe BCSI. Untess noted otherwise, top chord shall have properly attached structural sheathing antl bo m chak A� !t- . ZZ DRWG GBLLETI N1014 shall have a properly attached rigid telling. Locations shown for pernsnent lateral restraint f s �'1 V • /'L.. ALP i�.,� shall have bracing Installed per BCSI sections 'the J or Bet as unlessapplicable.no Apply plates to en ai -� /a I I I I L� IE Re truss and position as shown above and on the Joint ➢etatts, unless noted otherwise. •® �+d A L Refer to drawings 160A-Z for standard plate positions. • $$jj,, t • �� Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviotb r 'a••� ¢ o*• AN RWCOMPANY this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shp ®`•�rr`ea _`` MAX, T❑T, LD, 60 PSF Installation L bracing f trusses. / `y A seal on this drawing or cover page IIst4,g this drawing, bw/cates acceptance of professbnal f Suite RiverponDrive f y � responsibility te re paFor mttyy design �� �� pe'y�/TPI i s rra.►,g I �yyti�'0 /26/2020 DUR, FAC, ANY Suite 200 Maryland Heights, MO 63043 For more Information see this Job's general notes page and these web sites, MAX, SPACING 24,0' ALPINE, www,alpineltmooml TPI, www.tpinst,orgl SBCA, wwwsbclndustryarg/ ICG w.Iccsafearg IN r 4, Valley Detail - ASCE 7-101 160 mph, 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Dot Chord 2x4 SP #2N or SPF #1/#2 or better, Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, *3KAttach each valley to every supporting truss with) (2) 16d box (0,135' x 3,5'> nails toe -nailed for ASCE 7-10 160 mph, 30' Mean Height, Enclosed Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or ASCE 7-10 140 mph, 30' Mean Height, Enclosed Building, Exp, D, Wind TC DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown. Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are ITW BCG Wave Plates, 3X4 12 12 Max, I- 2X4 X4 �— 8-0-0 Max 4X4 12 12 Max, I 1X3 1X3 I (Max Spacing) 5X4/SPL 20-0-0 (++) Supporting trusses at 24' o.c, maximum spacing, Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% length of web, same species and grade or better, attached with 10d box (0.128' x 3.0') nails at 6' o.c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown In DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with: properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used In lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley Is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. Valle Spacing Pitched Cut Bottom Chord Valley � Le -nailed 2X4 Square Cut Bottom Chord Valeev `v, SQaGyypinunul •` j'a 2X4 4X4 -�5Tf Stubbed Valley ❑Ptional Hip End Detail Joint Detail ]4I �o�,�n 2''u0se� Partial Framing Plan .rINPtT2TANTn rWASH THIS DRAVING READ AND TD AALLL�CONTRACT�2S INCLUDINGA` L NUTES UN THIS THE INSTMIER P ®' {4'�6 .� LL 30 30 40PSF REF VALLEY DETAIL Trusses require extrene care In fabrlcating, handling, shipping, Instnlung and bracing. Re n I s TC DL 20 15 7 PSF DATE 10/Ol/2014 follow the latest edition of BCSI (Bulking Component Safety Infornatlon, by TPI and SBCA) f e n prnctices prior to performing these functions. Installers shall provide temporary bracing BCSIA w Unless noted otherwise, top chord shall have properly attached structural shwa hing and b am c*d Q ; BC DL 10 10 10 PSF DRWG VAL160101014 shall have n properly attached rigid telling. Locations shorn for permanent Intern: restratrn of b ® shall have bracing Installed per BCSI sections B3, B7 or BID, as applicable. Apply plates toe h efa s�1, _ ALPINE of truss and position as shorn above and n the bit Details, unless rated otherwise. • BC LL 0 0 0 PSF Refer to drawlnos Ton as for standard plate positions. • ,( 1 � AlPlne, division of ITV Building Co+ponents Group Inc. shall of be responsible for anyy devlatl o4r� 1 seer this dr..h any failure to build the truss In confornance with ANSI/TPI 1, or far handUng, Shipp : (� •rr�.orew (= � TOT. LD, 60 55 57PSF AN ITW COMPANY Instollatlon lS bracing of trusses. i A}4,% A seal on this drawing or cover page llsing this drawing, Indicates acceptance of professbnal a 9 514 Earth City Expressway engineering responsbitit solely for the design sham The suitabNty and use of this drorknp '$�/26/2020 DUR.FAC, 1.25/1.33 1.15 1.15 Suite 242 far any structure is the responsibility of the Bolding Designer per ANSI/TPI 1 Secz ;t1� Earth City, MO 63045 nor porerrw.Information see this Job's general notes page and these web sliest SPACING 24,0' ALPINE. alpinettw.comi TPI- www,tpinst.crgi SBCAi wwwsbclndustry.orgl ICG www]ccsafe,nrg VALLEY FRAMING & BRACING DETAIL R B( Lumber Size and Grade Minumum Requirements GENERAL NOTES Purlins required 2'-0" O.C. in absence of plywood sheathing. Trusses without sheathing applied must be evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this Is Impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2.5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'-0" or less -Maximum valley height: W-0" -Maximum mean roof height: 30 feet -ASCE 7-05,140 mph, Enclosed, Cat 11, Exp B,1=1.0, Kzt=1.0 -Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max. :e the crippes for each row starting from the valleys or sleepers working Inward to the ridge board so that cripple locations are gored between rows. ,7YP) innection Requirement Notes 2x6 rafters to ridge 4 16d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 416d toe -nails (••) 816d face -nails Rafter to sleeper or blocking 516d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 3 16d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 316d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 316d toe -nails CRIPPLE, BRACING, & BLOCKING NOTES ,....�.....,, 13. Collar beam to rafter 4 16d toe -nails NOTE: 16d (0.162"x3.5") COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0•'to 10'-0" long nailed w/ 2 -10d (0,148'W") nails. Or 2x4 "T' or scab reinforcement nailed to flat ede of cripple with 10d'0.128"x3.0") nails at 6" o.c. "T' or scab must be 90% of cripple length. Cripples over 10'-0' long requre two CLR's or both faces w/ "T' or scab. Use stress graded lumber & box or common nails. ,Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are installed Into ridge board -Install blocking under rafter if sleepers are not used. -Install blocking under cripples if cripples fall between lower truss top chords and lateral bracing Is not used. Apply all nailing in accordance to current NDS requiremen Nails are common wire nails unless noted otherwise. H• ��;1��GEMSF•. � � �. r (A) (B) avURNM TREAD Ale) fLuw CO rates a THIS aRAVnCi • C LL 20 30 40 54 REF VALLEY FRAMING e�•'[RTARra rt RNMR nos Irr MW Tn ALL r marES ON THIS DM TIE DSTALLfRS. '.�' Trusses requl-e extrene care In fabricating, hnrdlrp, shipping, Instalting and bracrg , Refer ta:ar1� • * • . follow the latest edition of SCSI �m+g eonponent Safety IMormt1m, by TPI and SBGU far sa%tlT 'C DL 10 20 7 7 DATE 10/01/14 Practices prior to perforning these functions. Installers stn4 provide temporary bracing per D • Unless noted other lse, tap chord shalt have properly attached structural sheathing and bottom-Jhord ; STATE OF e'er C DL 0 0 0 0 DRWG VACNV1801015 shot( have a properly attached rpld eelrp. Locations sheen for perronent lateral restraint of • Alf � r� rI� shall have bracing l otns shown per abo sections th J nt Det as antess no dApptywt plates to each fo�:e i i �� lul�\vlI Re truss and pasroan as fors above and an the .ldnt melons, rwtess noted nther•ke •..A% A .° ,f+ffBC LL 0 0 0 0 1 �— .I Refer to drarrtps 160A-2 for standard plate posftlons. �� • f _ • , IVJ iTWCOMPANY tit any falvon of mt build thr N eonforn°ncCv-ojp Inc. ea tt ANSeI/ PI La or�irar�mtp �n f O� (((•���••l �R1O••' \e ��•` TOT. LD.30 50 47 61 tw:tdwtion drawing, is d o of trusses. s/ON�� � � A_ seal on this dro•rp or cover pope design this n, acing, kxficates acceptance of professional / tp� eddy For the d�s�r� ehn•n The 13389 Lakefront Drive f0f•' r•`pOf`�h' °f �" �� Designer W A n^PRL 1dse� �a�g llitttttNtt' DUR. FAC. 1.25/1.15 Earth City, M063048 For more kMorm n; T see this ,lab's geSBM ^°te getr erg te��r.�feorg ® 20 l� SPACING SEE ABOVE ALP1IFi enAlprrelt rnati TPD eethis job's gi Sera wee.