HomeMy WebLinkAbout211847-2d compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:211847-2d/CH/bm PERMIT #:NUC #417 CONTRACTOR:Bill Webster Tractor Services Nuc Model:3500 JOB LOCATION:1310 Copenhaver Road Nuc Serial #:3417 Fort Pierce, Florida ITEM TESTED:Compacted Foundation Fill - Final Lift TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.E.0" - 12"45+107.4 108.6 98.9% 2. S.E.""107.1 "98.6% 3. Center ""106.9 "98.4% 4. N.W.""106.2 "97.8% 5. S.W.""107.5 "99.0% Soil Description: Brown Sand In Place Moisture: 7.4% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 108.6 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 3/22/2021 Email to: St. Lucie County Building Department ; brett.webster@yahoo.com Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 March 19, 2021 2011-0476 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 104.0 105.0 106.0 107.0 108.0 109.0 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight