HomeMy WebLinkAbout8501 CHAMPIONS WAY, PSL, FL - MAINSTAY SUITES PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 03/19/2021 Permit Number:
O
V Building Permit Application
Planning and Development Services
Building and Code Regulation Division Commercial X Residential
2300 Virginia Avenue, Fort Pierce FL 34962
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT APPLICATION FOR: 200 GALLON STORAGE TANK FOR BOILER
PROPOSED IMPROVEMENT LOCATION: MAINSTAY 8501 CHAMPIONS WAY, PSL, FL 34986
Address: MAINSTAY SUITES 8501 CHAMPIONS WAY, PORT SAINT LUCIE, FL 34986
Property Tax I D #: 3327-708-0009-000-9
Site Plan Name: PGA COMMERCE CENTRE AT THE RESERVE COMMERCIAL PARCEL 1 (3.210 AC)
Project Name. Sec/Town/Range: 27/36S/39E
I DETAILED DESCRIPTION OF WORK:
Lot No.
Block No.
REMOVING & REPLACING COMPROMISED 200 GALLON WATER HOLDING TANK IN UTILTITY ROOM
New Electrical Meter Second Electrical Meter
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
Mechanical
Electric
Gas Tank
Plumbing
Total Sq. Ft of Construction:
Cost of Construction: $ 15,975.00
—Gas Piping
Sprinklers
_ Shutters _ Windows/Doors _ Pond
_ Generator
Sq. Ft. of First Floor:
Roof Pitch
Utilities: —Sewer _Septic Building Height:
OWNER/LESSEE:
CONTRACTOR:
NameTWC PORT SAINT LUCIE LLC
Address:40 W 57TH ST FLOOR 29
City: NEW YORK State: Uy
10019 N/A
Zip Code: Fax:
Phone No.772-480-9763
Name: MATT BLACK
Company:BENJAMIN FRANKLIN PLUMBING
Addre55:6945 NW LTC PARKWAY
PORT SAINT LUCIE FL
City: State:
Zip Code: 34986 Fax: 772-871-9069
Phone No772-871-9494
E-Mail:TIM.WHALEY@AIMHOSP.COM
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail PERMITS@BENF'RANKLINPLUMBER.COM
State or County License CFC-1 430437
IT value aT construction is e5uu or more, a KFIL01I -0 Notice of Commencement is required.
If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER-
Name:_
Address:
City: `
Zip:
Phone
FEE SIMPLE TITLE HOLDER:
Name:
Address:
City:
Zip: Phone:
k Not Applicable MORTGAGE COMPANY: x Not Applicable
Name:
State
x Not Applicable
Address:
City: State:
Zip: Phone:
BONDING COMPANY:
Name:_
Address:
City:_
Zip:
Phone:
x Not Applicable
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. LucieCount makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Houle Owners Association rules, bylaws or and covenants that may restrict or prohibit such
Structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorneyci
before commenn work or recordin our Notice of Commencement, _
Signature of Owner/ Lessee/Contractor as Agent fur Owner I Signature of Contractor/License Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTY OF 5� /_U COUNTY OF a LuUC
Sworn to (or affirmed) and subscribed before me of
c� Physical Presence or Online Notarization
this _L�— day of Z029 by
Name of pe4on making 56tement.
Personally Known OR Produced Identification V
Type of Identification
Produced L
nature
"F"� JIJUE JANE MCCAULEY
Notary Public State of F
Commissic ICI
r 7.1on # HH 498
MY Comm. Expires Oct 1, 2024
REVIEWS FRONT ZONING
i COUNTER I REVIEW
DATE
RECEIVED
DATE
COMPLETED
Sworn to (or affirmed) and subscribed before me of
Physical Presence or Online Notarization
this _iL day of MAnh 2024 by
Name of person making statement.
Personally Known Z OR Produced Identification
Type of Identification
Produced
(Signat
JULIE JANE MCCAULEY
?a • `: Notary Public - State of Florida
Commiss Yd •' lssica "''H 49824 l
My Comm. Expires Oct 1, 2024
Banded throe h Na i n
SUPERVISOR PLANS VEGETATION SEA TURTLE
REVIEW I REVIEW REVIEW REVIEW
MANGROVE
REVIEW
Large Volume Commercial Storage Tanks
Ruu
Available in
Jacketed
and
Non -Jacketed
Models
Available in 200, 260, 320, 430, 500, 750 and 950 Gallon Models
Rheem-Ruud commercial storage tanks are vertical tanks designed for
applications that require large quantities of potable hot water in short periods
of time. When used in tandem with RHEEM-RUUD commercial water heating
equipment, these storage tanks provide the flexibility needed for many
commercial applications. Installed individually, or manifolded, these storage
tanks can provide 80% draw capability without an appreciable temperature
decrease in single temperature applications.
Construction Features:
• Long life tank design
unique steel formulation with high
temperature porcelain enamel to
maximize corrosion resistance
resulting in a superior tank
design. Heavy duty magnesium
anode rod(s) are installed for
longer tank life.
• ASME
all large volume commercial
storage tanks are certified to
ASME boiler and pressure vessel
code standards.
• Efficient design
2" of rigid polyurethane foam
insulation provides superior
insulating qualities resulting in
reduced operating costs.
• Tank openings
circulating line /cold inlet
connections are 3" NPT (2-1/2"
on 200 gallon) and hot outlet is 2".
Certifications and Ratings:
• Efficiency —jacketed models meet or exceed thermal efficiency and
standby loss requirements of current ASHRAE standards (Part of the
Federally mandated Energy Policy Act (EPact).
ASME Recommended Specifications (Jacketed Models):
Storage tank(s) shall be RHEEM-RUUD model . Storage
tank(s) shall have a storage capacity of gallons. Tanks) interior
shall be coated with a high temperature porcelain enamel and furnished
with magnesium anode rod(s) rigidly supported. Storage tank(s) shall be
constructed in accordance with the requirements of the ASME Boiler and
Pressure Vessel Code, stamped and registered with the National Board of
Boiler and Pressure Vessel Inspectors. Tank(s) shall have a working pres-
sure rating of psi. Tank(s) shall be insulated with a minimum of 2" of
rigid polyurethane foam insulation. Storage tank(s) shall be covered by a five
year limited warranty against tank leaks.
Limited Warranty
This product features a five year limited warranty against tank leaks. Please
refer to Commercial Warranty Certificate for complete information.
Continued on reverse.
Large Volume Storage Tanks continued.
1 1+
MODEL
NUMBER UNITS
!• + I
A B
1•
C
� � 1 �
WATER CONNECTIONS
D OUTO ET FRONT
�
APSHI PROX.
WEIGHT
ST200A
inches
79.112
34
1 13-3116
18-3116
2-112
2.112
872lbs.
mm
2019
864
1 335
462
64
64
395 kgs.
ST260A
inches
95-112
34
18
26
2
3
1108lbs.
mm
2426
864
457
660
51
76
503 kgs.
ST320A
inches
84-112
40
19.314
27-114
2
3
1290lbs.
mm
2146
1016
502
692
L 51
76
586 Kos.
ST430A
inches
84.112
46
21
29
2
3
1626lbs,
mm
2146
1168
533
737
51
75
738 kgs.
ST500A
inches
94-112
46
21
29
2
3
1766lbs,
mm
2400
1108
533
737
61
76
801 k s.
ST750A
inches
107-112
54
22-718
30-718
2
3
2330lbs.
mm
2731
1372
5$1
784
51
76
1058 kgs.
ST950A
inches
131-112
54
22-718
30-718
2
3
3010lbs.
mm
3340
1372 1
681
784
51
76
1367 k9s.
■,
INUR
,
UNITS A B
�+
C
WATER CONNECTIONS
TOP FRONT
D OUTLET SIDE
APPROX.
SHIPPING
WEIGHT
00A
inches
75-314
30
10-15116
18.7/16
2-1/2
2-112
4881bs.
mm
1924
762
278
469
64
64
222 k s.
STU260A
inches
88
30
15-314
23-314
2
3
464lbs,
mm
2235
762
400
603
51
76
211 k s.
STU320A
inches
76
36
17-318
25-318
2
3
674lbs.
mm
1930
914
441
645
51
76
261 kgs.
STU430A
inches
76
42
18-718
26-718
2
3
8161bs.
mm
1930
1067
479
683
51
76
370 kgs.
STU500A
inches
88
42
18-718
26.718
2
3
925lbs.
mm
2235
1067
479
683
51
76
420 kgs.
STU750A
inches
100
46
20-718
28-718 1
2
3
1387lbs.
mm
2540
1219
530
733
51
76 1
630 kgs.
STU950A
inches
124
48
20-718
28-718
2
3
1651lbs.
mm
3150
1219
530
733
51
76
750 kgs.
TANK INFORMATION,
MODEL
NUMBER
MAXIMUM
TANK CAPACITY WORKING
PRESSURE
GALLONS LITERS ASME
ST(U)200A
200
758
150 PSI
1034 kPa
ST(U)260A
257
974
125 PSI
862 kPa
ST(U)320A
318
1205
125 PSI
862 kPa
ST(U)430A
432
1637
125 PSI
862 kPa
ST(U)500A
504
1910
125 PSI
862 kPa
ST(U)750A
752
2850
125 PSI
662 kPa
ST(U)950A
940
3563
125 PSI
862 kPa
B
A
w•�
i
0
I ! it wuu
For model ST200A only.
w
A
n
For model STU200A only.
For ST260A,ST320A,
ST430A, ST500A, ST750A
and ST950A models.
For STU260A, STU320A,
STU430A,STU500A,
STU750A and STU950A
models.
RUUD
C O M M E R C I A L
W A T E R N E A T E R$
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
Rheem Canada LtdJLtee - 125 Edgeware Road, Unit 1, Brampton, Ontario L6Y OP5
PAINTrU A U.S.R. 12/11 WP FORM NO, RR102G-3LT Rev. 9
NOTICE OE COMMENCEMENT
Permit No.
State of Florida County of 5t, Lucie
Tax Folio No. 3327-708-0009-000-9
i Vl
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement.
Legal Description of Property: (and street address if available):
General description of improvement; REPLACE COMPROMISED 200 GAL HOLDING TANK
Owner information or Lessee information if the Lessee contracted for the improvement:
Name TkAN` PtIPT CAINIT I I It-ir! I I n
Address
Interest in property:
Name and address of fee simple titleholder (if different from Owner listed above);
Contractor's Name:
Contractor Address:
Phone Number: 772-871-9494
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $ N/A
Name and address: N/A Phone number: N/A
Lender Name: N/A
Lender's addres
Number: N/A
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13(1) (a)7., Florida Statutes:
Name: P
Address:
Phone Number: N/A
In addition to himself or herself, Owner designates N/A of N/A to receive a copy of the
Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner: N/A
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge and belief.
(Signature of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager
(Signatory's Title/Office)
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was acknowledged before me by means of O physical presence or CI online notarization this day of _
20Jby who is personally known to me or has produced as identification.
[NOTARIAL SEAL]
NOTARY PUBLIC. State of Florida