Loading...
HomeMy WebLinkAboutEvaluation Report; Fiberglass Door inswing & Outswing ImpactR W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida; Board of Professional Enbrineers Certificate of Authorization No. 9813 Product Sub Category 1Manufacturer Product Name Category Ther`ma-Tra Corporation Smooth Star, fiber Classic, Classic Craft Exterior Swinging Exterior Door 118 Industrial Drive and'Classic Craft Rustic Fiberglass Door Doom Assemblies Edgerton, O1,143517 Inswing/Outswing Phone 419 298-1740 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Therma-Tru Corporation based on Rule Chapter No. 61 G20-3, Met4od 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product icomplies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 1 4. When used in areas outside of the--HVHZ-- requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This products meets missile level"'D" and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the detailsi of drawing FL-10537.1 require further engineering analysis by a licensed engineer or registered architect. I 7. Outswing configurations using coastal sill item 94 meet water infiltration requirements for "HVHZ". 8. Inswing configurations and outswing configurations using threshold item #5 do not meet the water infiltration requirements for the "HVHZ" and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 9. See drawing FLA 0537.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 01460336-A,B,C STTS00001 15427-107362 AT167508.01-106-18 TEL 06-1031-1 2. Drawing No. No. FL 10637.1 Test Standard � ASTM 1)635-03 ,� ASTM D1929-96 ASTM D2843-99 ASTM G26-95 ASTM E84-00a ASTM D 1929-96 TAS 201-94, TAS 201-94. Testing Laboratory Signed by Testing Evaluation Lab.,lnc. Lyndon F. Schmidt, P.E. Sub Tropical Testing Omega Point Laboratories Architectural Testing, Inc. TAS 203-94 Testing Evaluation Lab.,lnc. Prepared by RW Building Consultants, Inc. (CA #9813) 3. Calculations Prepared by a'`'t " %fad Anchoring RW Building Consultants, Inc. (CA #9813)��Y-���> 4. Quality Assurance Certificate of Participation Issued by National Accreditation and �;0'' Management Institute, certifying that Therma!Tru Corporation is d# k .0 4.,m"fix manufacturing products within a quality•assurance program that complies with ISOIIEC 17020 and Guide 53. n Sheet 1oflp� rn tr;a Lon Hicks, VP Operations William E. Fitch, P.E. Joseph A. Reed, P.E. Wendell W, Haney, P.E. Sianed & Sealed by Lyndon F. Schmidt, P.E. Sianed & Sealed by Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 1/30/2015 THERMANTRU THERMA TRU DOORS 1 1 6 INDUSTRIAL DR., EDGERTON, OH 4351 7 SMOOTH STAR, FIBER CLASSIC CLASSIC CRAFT & CLASSIC CRAFT RUSTIC " 7 FIBERGLASS DOOR MUMA INSWING / OUTSWING X-rs-A �,IMPAcr a7��n�,GES ,ENERAL NOT T- �f1is product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). Z Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shah be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product comples with Section 1626 of the Florida Building Code and does not require on impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection this product complies with Section 1609.12 of the FBC and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.22 of the FBC. 5. For 2x stud framing construction, anchoring of these units shag be the some as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this droving require further engineering analysis by a licensed engineer or registered architect. 7. Outswing configurations using coastal sill item #4 meet water infiltration requirements for "HVHZ". 8. Inswing configurations and outswing configurations using threshold item #5 do not meet the water infiltration requirements for the "HVHZ" and shag be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. SHEET s 1 cross 37.75" MAX. OVERALL FRAME WIDTH 35.93' MAX. PANEL WIDTH 0 m x = w c� � x q w 41 � O c� m SMOOTH INSWING 37.75' x 82.25" +75.0 STAR OUTSWING 37.75" x 80.75" +80.0 CLASSIC INSWING 37.75- x 82.25" +100.0 CRAFT OUTSWING 37.75" x 80.75" +100.0 CLASSIC INSWING 37.75' x 82.25' +90.0 CRAFT OUTSWING 37.75' x 80.75' +90.0 RUSTIC FIBER INSWING 37.75" x 82.25' +75.0 CLASSIC OUTSWING 37.7S' x 80.75" +80.0 -75.0 -80.0 -100.0 -100.0 -90.0 -90.0 -75.0 -80.0 BY.. AL BY. LFS WING NO., FL-10537.1 Er 1 OF 10 L DETAIL A -A J 40 DOOR PANEL Smooth Star NOTE: WOODILVL COMPONENTS: PINE (SG >= 0.42) 00000000 0000000 00000000 0000000 00000000 0000000 00000000 0000000 O O 00000000 0000000 00000000 ?� 0000000 00000000 0000000 28.66%OPEN AREA MAX A DETAIL A -A Panel reinforcement HORIZONTAL CROSS SECTION 4.1(r �{ CS )Mir � TOP RAIL 43 10CKSfILE r 1.53' F � BOTtOM RAIL ' EXTERIOR INTERIOR [2"� VERTICAL CROSS SECTION 2 (� N q � M A3 En O N m Z v 0 0 Z a gL° 9m cw a Ng =ota mda� s 0 E cc = cw �a LO Jr �p p� 4�y WI=- g s �o 0 a a ;. BY.- AL Ila ar: LFS 3 ANG NO.: � P FL-10537. T °o FT 2 OF 10 N TYP. 4 CORNERS OF PANEL L DETAIL A -A J 50 DOOR PANEL � Clasic Craft NOTE WOODIM COMPONDM: OAK CAP. PINE CORE ISG > 0.42) 00000000 0000000- 00000000 0000000 00000000 0000000 00000000 0000000 O O 00000000 0000000 00000000 r 0000000 00000000 LC 0000000 28.86%OPEN 00000 AREA MAX. 0000 0 00000 0 0000000 00000000 0000000 00000000 DETAIL A -A Panel reinforcement r 1.44• y1 03C T �. HINGE Si1LE 4.06" 0.37' --� EXTERIOR 53 LOCKSTIIE �+ l Ar ro cQ SS BOTTOM RAIL ............. ' I N 'rl3r• •� (S ; n to d Q;: 2 Z * � :6Q S 2 0- C—� n III" •��'•...y....• `��.�`` N > � � 111111 it. ``` 0 N Z \ v Z oZG t° 9mcw oa Nq maI2 C 4 Z 3a J o ¢t z0 0� r U WU m ¢in 3 it N �U UI K C3 0 INTERIOR 0 ri'�\ VERTICAL CROSS SECTION 3 M. N.T.S. er: AL d BY. LFS 3 WING N0: C a FL-10537.1 c " Er 3 OF 10 OL 40 4 13 mo IYCSOI-1J m p =0N OH4N i Sjl 'A m 1V '%8 c o so/tiz/z 3 C � rn 0 N Cn n C =a C vo0- 4.. 'O 04.0T! m' m m3 e y oZ 9 m O Z ```%�\ w {{I1 lII mSc cm 24 Z VWcsr pp *S p W Wo 0 ID CI m ll NOU:RS SSOV 1VJ1183n Z NORf31NI 80IN31M PUS d9NIH 10 001 S 13 N01103S SSOV 1VINOZISOH L luawa0joluie! lau0d V-V Will 0000000 000000 0 0000 >rNVV3bV o0000 0000 N3dO %99"9L 000000 0000000 � 000000 0000000 000000 0000000 00 000000 0000000 000000 0000000 000000 0000000 000000 0000000 000000 000 IZb•0=c OS) 3M003NId'dVJ:IVO ;S1t8NOdW00 W/COOM'MON �lmN 1W+J �qO OE 0 13NVd!lOO(7 F V-V IlVJ30 7 l3NVd 30 SM3NNOZ) v'dxL 66 EXTERIOR �u 7,77, INTERIOR HORIZONTAL CROSS SECTION L DETAIL A -A J (Fy DOOR PANEL NOTE WOODILVIL COMPONENTS: PINE (SG 0.421 00030000 0000000 00000000 0000000 00000000 0000000 00000000 0000000 0 00000000 0000000 00000000 0000000 00000000 rf 0000000 0000000 28.86% OPEN 00000 AREA MAX. 0000 0 00000 0 0000000 l 00000000 0000000 00000000 DETAIL A -A Panel reinforcement En CS m < EXTERIOR INTERIOR 0 MI A o 0 rx � TOP RAIL � LOCK STILE 111 1,:: IT 61 1.53- 66 � HINGE STILE � BOTTOM RAIL K2 VERTICAL CROSS SECTION SCOLL N.T.S. DWG. BY: AL a CHIC ErY-. LFS DRAWING NO.: FL-10537.1 C C SHM7 OF L 0- - R1Clents The a Tru PERMANEURFloride Product A ravels \FL-IOS3 Drmin s Current FL-10537. 1-6 A Z e> a e o m • e. O m�� r_ ' A lXN CA rn T N _ O O '9 Z (j2 .O Z C 4 o $ VW v Z ti V P m 70 A M ;1 A V N V A •Q V f!r M A_ M 30 Q .T7 AA� C3 � o O X M _ Z c � M fi A A O n 70 O a a aZ D n p W O O Uf W -0 Z .. m v 7 Co� O mO "ziq p � A 3' 7A0 �O N 5CA r- 9 O °a Z p• p M v v v o. .p . o �Z No.43409 o T n $ PRODUCT: THERMA-TRU DooumretrrF. Prepared By., BTATEOF ; Lyndon Schmidt •........•.... '�i Fjpq♦♦♦� Ig r z \ FIBERGLASS DOOR i�••••• P.E. No. 43408 �j�''O��• i!T'♦♦ ` INO r y y cn o2 e/ t✓ BUILDING CONSULTANTS, IIUc" '1!I/ P.O. Box 230, Valrteo, FL 33595 1 28 15 UPDATE TO STH ED. 2014 FBC JK PART OR ASSEMBLY:. 27 12 UPDATE TO 2010 FBC RW to tO HORIZONTAL YYYIIY Phona No.: 813.859.9197 DATE BY CROSS SECTIONS FBPE C.A. No. 9813 REVISIONS 0 2009 R.W. Bumoemo CGNau LTA— INC. R.�Clients Thenna Tro PERMANE Flodda Product A rovals FL-1053 Dr —in s Current FL-10537 1-7 I rn rn � V � O v .'O °� �0° A �� O D ur �m C) • p rn o p, =N°O Om Z p °co M O _M o— Z O v Z v ° •O O ° m 0.15' a. v MINK —� p O (TYP.) ao g A 1-1/4'NIIN. m EMB. (TYP.) v. rXT7 ,,pp rn o. O O rnO O n V N ° O p W < m (D R (p M ';M. ; 'i'ii ryN� n pp rn X J 20 Cr p o y Cn Z O a e •o .O O V O O m A 0 n° n I O m 1-1/4" MIN. FMB. (TYP.) A v. to ? .s0- _ nID Mp A ^I O D o c, C<co� ninon " �M �yRm S v. 0 ° °faon�c � v 00 0 m 0 O o y o .. m °a p• en 'ca M °v a rn ' No. 43409 r i PRODUCT: THERMA—TRU Documonb Props d ! BUiE OF •• Lyndon F. Schmidt ��i��••• �C(�IOt;� •� I� I o t^ FIBERGLASS DOOR ��� P.E. No. 43409 I��ISS�O%iA�. o W `' f y (�DBUILDING CONSULTANTS,1 (h� 2 i 28 15 UPDATE TO 5TH ED. 2014 FBC JK PART OR ASSEMBLY: 2DATE72 UPDATE 7I 2010 FBC to D ti r rO VERTICAL 0. Box3813.859.9197 33595 °J,,sY NO BY CROSS SECTIONS Phone No2P REVISIONS FBPE C.A. No. 9813 Na' 6CO9 R.W. 9NILDIND CONSULTANTS IND. O.C. d 4" �{ )•.- O.C. (TYP. 4" N 77-7 I � � 6- jam ,•. z • rc�i Q, o m \ 'In tF ```\ a n m Z TYP. D TYP. D L k eep E. Z_ m° Z. a [A p L 9 C W y TYP. HEAD & c� a '�' " m i a MASONRY MASONRY a MASONRY JAMBS \ V OPENING OPENING ` OPENING E of 3d FRAME/XZ -2X BUCK-,,.,- - -- - - - 2X'BUCK-- --- - - - -�� - - --- — - -- - ----- - - - - - - - - - - - - - r- - Q a - p N 2X BUCK o Op' y 0� Ck: �� QO f 2W a LU O yU -• al a mm X3)- � K m BUCK ANCHORING BUCK ANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB DP <= 80 psf 80 < DP <=100 psi Masonry 2X buck construction m CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 2. Concrete anchor locations noted as 'MAX ON CENTER" must be adjusted to mairtoin the min. edge distance to mortarjoints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. - o' 3. Concrete anchor table: /iNGNt311' =ANCNO!!1 MftY M. Ct . C£ MfN C...E,4RANC.. I1fPE SIZE J M13bAAENrt 70:ff..... NRY TOADJAC'FNT.-: ........ ....... ......EDGE.; ANCHOR:-:.;:: IiW ® TAPCON 1/4" 1-1/4" 2" 4" ELCO ULTRACON 1/4" 1-1/4" 1" 4" WOOD SCREW INSTALLATION NOTES-- 1. Maintain a minimum 518" edge distance, 1"end distance, & 1"o.c. spacing of n wood screws to prevent the splitting of wood. a HINGE DETAIL LATCH & DEADBOLT DETAIL u: N.T.S. BY. AL BY. LFS WNG NO, FL-10537.1 fr 8 or 10 E MASONRY OPENING FRAN 1X BUC HINGE JAMB FRAME ANCHORING STRIKE JAMS o` - Masonry 1X buck construction CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. e edge distance to mortar joints. 2. Concrete anchor locations noted as MAX. ON CENTER" must be adjusted to a maintain the min. edge distance to mortar joints, additional concrete anchors omay be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: "ANCHOR':: ANCHdR Mffl. M.IN CLEARANCE -AKlN CLEARANCE: iYPE SRf EMBEDMENT MMASONRY LOAMUCENT.: . EDGE ANCHOR ITW ® TAPCON 1/ 4" 1-1/4" ITW TAPCON® 3/16" 1-1/4" 3" 1-1/2" al IYVVU JVRCIY IIVJIl1LLH11VIV IV V I W. 1. Maintain a minimum 518" edge distance. I"end distance. 8. 1"o.c. spacing of wood screws to prevent the splitting of wood. a a LATCH d DEADBOLT DETAIL HINGE DETAIL N '�/y�` = W M7 I ,it _ 1•�` o n Z IIll1 •. 9 Z Z U e m 8 56 `oa N ug a Nw ma. s4 zd C IF: N.T.S. er AL a BY.. LFS 3 WhIG NO.: O FL-10537.1 2 sr 9 OF 10 ° BILL OF MATERIALS REM DESCRIPTION MATERIAL ITEMI DESCRIPTION MATERIAL A 1 X BUCK SG 2 0.55 WOOD 30 CLASSIC CRAFT RUSTIC DOOR - SEE DOOR PANEL DETAIL SHEET FOR DETAILS B 2X BUCK SG 2 0.55 WOOD 31 DOOR SKIN 0.095' THK. (CC RUSTIC) Fy = 6,000 PSI MIN. FIBERGLASS C MAX. 1 /4" SHIM SPACE 32 TOP RAIL CLASSIC CRAFT RUSTIC WOOD D 1/4" X 2-3/4" ELCO OR ITW CONCRETE SCREW STEEL 33 LOCK & HINGE STILE (CLASSIC CRAFT RUSTIC) WOOD/LVL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 34 BOTTOM RAIL (CLASSIC CRAFT RUSTIC) COMP. 35 PANEL REINFORCEMENT 0.023" THK. CLASSIC CRAFT RUSTIC STEEL G 3/16" X 3-1 /4" ITW CONCRETE SCREW STEEL 36 FOAM CORE POLYURETHANE H 1/4" X 3-1/4" ITW CONCRETE SCREW STEEL 40 SMOOTH STAR DOOR -SEE DOOR PANEL DETAIL SHEET FOR DETAILS J 1/4" X 3-3/4" TW CONCRETE SCREW STEEL 41 DOOR SKIN 0.065' THK. SMOOTH STAR Fy = 6,000 PSI MIN. FIBERGLASS L # 10 X 2-1 /7' PFH WOOD SCREW STEEL 42 TOP RAIL (SMOOTH STAR) COMP. 1 INSWING ADJUSTABLE THRESHOLD (LS300AJ) ALUM./WOOD 43 LOCK STILE (SMOOTH STAR) WOOD/LVL 2 INSWING THRESHOLD (IS300HP51 ALUM./COMP. 44 HINGE STILE (SMOOTH STAR) WOOD 3 INSWING SELF ADJUST THERMAL BREAK THRESHOLD (ISP30M) ALUM./COMP. 45 BOTTOM RAIL SMOOTH STAR) COMP. 4 OUTSWING COASTAL THRESHOLD ALUM./WOOD 46 PANEL REINFORCEMENT 0.023" THE. SMOOTH STARJ STEEL _5 OUTSWING STANDARD THRESHOLD _ ALUM./WOOD 47 FOAM CORE POLYURETHANE 6 INSWING THRESHOLD ALUM./COMP. 50 CLASSIC CRAFT DOOR -SEE DOOR PANEL DETAIL SHEET FOR DETAILS - 7 DOOR BOTTOM SWEEP VINYL 51 DOOR SKIN 0.095'THK. CLASSIC CRAFT = 6,000 PSI MIN. FIBERGLASS 8 JAMB PINE SG >= 0.42 SMOOTH STAR, FIBER CLASSIC WOOD 52 TOP RAIL CLASSIC CRAFT) COMP. 9 JAMB (OAK) SG >= 0.67 (CLASSIC CRAFT & CC RUSTIC) WOOD 53 LOCK STILE (CLASSIC CRAFT) WOOD/LVL 10 WEATHERSTRIP FOAM 54 HINGE STILE CLASSIC CRAFT) WOOD/LVL 11 HINGE STEEL 55 BOTTOM RAIL CLASSIC CRAFT COMP. 12 #10 X 3/4"PFH SCREW STEEL 56 PANEL REINFORCEMENT 0.023" THK. CLASSIC CRAFT STEEL 13 #9 X 3" PFH WOOD SCREW STEEL 57 FOAM CORE POLYURETHANE 14 LATCH STRIKE PLATE STEEL 60 FIBER CLASSIC DOOR -SEE DOOR PANEL DETAIL SHEET FOR DETAILS 15 SECURITY STRIKE PLATE STEEL 61 DOOR SKIN 0.065' THK. FIBER CLASSIC Fy = 6,000 PSI MIN. FIBERGLASS 16 #8 X 2-1/7' PFH SCREW STEEL 62 TOP RAIL FIBER CLASSIC) COMP. 17 #8 X 3/4" PFH SCREW STEEL 63 LOCK STILE (FIBER CLASSIC) WOOD/LVL 18 KWIKSEF PASSAGE LOCK -SIGNATURE SERIES _ STEEL 64 HINGE STILE FIBER CLASSIC) WOOD 191 KWIKSET DEADBOLT -SIGNATURE SERIES (980) STEEL 65 BOTTOM RAIL (FIBER CLASSIC) COMP. 66 PANEL REINFORCEMENT 0.02WTHK. FIBER CLASSIC STEEL 67 FOAM CORE POLYURETHANE (-�- 5.75' 0 rn�l 5 THRESHOLD Ouhwing standard 5.85" m 2 THRESHOLD Insvnng adjustable Fes— 5.83' A. 6 THRESHOLD Insw.ng mmc dp rating =+/- 50.0 psf 5.87" to 3 THRESHOLD hawing self-acrjust I-� 4.56" I � 9 L1 HEAD 3 SIDE Jamb 4 THRESHOLD Outswing coastal \N n -,,•.91 a A,% N>°nm ` On m Z O N .: e y O oZ? Em z m ` oo Y 0 o a. `n7 mm a12 v a ^d z M N.T.S. BY: AL C. ar: LFS WNG NO, FL-10537.1 rr 10 OF 10