HomeMy WebLinkAboutProduct Approval; Metal Roofing�� ,y, aua uuttutil�' %-vuc Vllllne
,19ti trC('a'i`1`t BCIS Home Log In ! t
Business-` )
Hot Topics Submit Surcharge Stats & Facts
Pagel of 2
"
Rmwk=
k
Publications F8C Staff BCIS Site Map Links Search
Protessi ' al kA Product Approval a .,
USER: Public user C.
. I, P%1
Reaulation
je Product Approval Menu > Product or Application Search > 6polication Ltsk > Application Detail y�
FL #
.
12. x
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL14520-RI
<::
n
ZZro2ed
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
I
Certificate of Independence
J A TAYLOR ROOFING
302 Melton Drive
FT PIERCE, FL 34982
(772) 466-4040
flvalidation@yahoo.com
Kyle Taylor
flvalidation@yahoo.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
r Evaluation Report - Hardcopy Received
Charles L THOMAS
PE-29439
Keystone Certifications, Inc.
04/11/2021
Locke Bowden
F Validation Checklist - Hardcopy Received
FL14520 RI COI Certificate of Independence FDA —if
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
Equivalence of Product Standards
Certified By
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquxTVBjriReYsCCTD3D3z4Qf6p09... 1 /16/2012
>viiuc uu1,u111g wue unune
Page 2 of 2
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted
11/07/2011
Date Validated
11/07/2011
Date Pending FBC Approval
11/10/2011
Date Approved
12/06/2011
of Products
FL # Model, Number or Name
14520.1 115, V CRIMP
Limits of Use j
Approved for use in HbHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-129.25
Other: The required design wind loads shall be
ietermined for each project per the Florida Building
.ode. The maximum fastener/clip spacing listed herein
:hall not be exceeded. This product is not evaluated for
Ise in the High Velocity Hurricane Zone.
..__9Mty ._.__.---- —
_. _— —
26GA METAL ROOFING PANEL
Installation Instructions
FL14520 R1 II 5V Crimp Evaluation
Verified By: PRI Construction Materials Technologies,
LLC
Created by Independent Third Party: Yes
Evaluation Reports
FL14520 R1 AE 5V Crimp Evaluation Report Rev pdf
Created by Independent Third Party: Yes
Back ��nsext
Contact us :: 194p North Monroe Street Tallahassee Ft 32399
The State of Florida Is an AA/EEOlemployer. Conyrioht 2007.201Q State of Florida :: Privacy Statement :: A4cessibility Stat ment :: Refund Stat ment
i
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not
send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web
accessibility, please contact our Web Master at Lvebm8ster@dbPr.state.fl.us.
Product Approval Accepts:
Wr 9 eCAeck M
%ccuritym i:TWQ ttx
M.
I
htt //floridabuildin .or / r/ r_a P $ g p p pp_dtl.aspx.param=wGEVXQwtDquxTVBjriRcYsCCTD3D3z4Qf6pO9... 1/16/2012
J.A. Taylor Roofing Inc:
Evaluation Report for
26 ga. 5V Crimp Metal Roof Assembly
FL# 14520-R1
Evaluation Report
Report.for: J.A. Taylor Roofing Inc. Date: November 3, 2011
302 Melton Drive
Fort Pierce, FL 34982
Building Code.-2010 Florida Building Code Compliance Method: Rule 9N-3.005(1)(d)
Section(s): 1504.3.2 Category: Roofing
Project No.: FAE-001-01-01 Sub -Category: Metal Roofing
Scope: Product Category. Roofing
Sub -Category. Metal Roofing
Compliance: The 26 ga; 5V Crimp Metal Roof Assembly described
herein has demonstrated compliance with Section
1504.3.2 of the 2010 Florida Building Code.
I
References: Test Application Standard (TAS) 125-03 Standard Requirements for Metal
Roofing Systems, Section 8 testing pursuant to Hurricane Test Laboratory, LLC
(FBC Organization ID No. TST1527) report no. 0224-0501-06, dated October 31,
2006.
Report addendum for report no. 0224-0501-06 (Specimen #1, 2, &4) issued by
Hurricane Test Laboratory, LLC (FBC Organization ID No. TST1527), dated
September 28, 2011
Drawings # '26" 5V 24' Coverage' issued by Hurricane Test Laboratory, LLC
(FBC Organization ID No. TST1527), dated September 20, 2011.
Engineering Analysis by PRI Construction Materials Technologies (FBC
OrganizI ation No.TST5878), dated April 19, 2011.
Product Description: 5V Crimp panel, minimum 26 ga. corrosion resistant steel (Grade 80), 26" panel
(24. maximum coverage), W ribs; material shall comply with 2010 Florida
Building, Code, Section 1507.4.3.
Minimum #9-15 HWH corrosion resistant fasteners with sealing washers
designed for metal to wood connections of sufficient length to penetrate 5/16"
through the sheathing. Material shall comply with 2010 Florida Building Code,
Section 1507.4.4.
Limitations: Limitations and Conditions of Use include the following.
• This' evaluation does not include use of the product within the High -Velocity
Hurricane Zone (HVHZ).
• Fire Classification is not within scope of this Evaluation Report; refer to a
current Approved Roofing Materials Directory for fire ratings of this product.
Page 1 of 3
JA. Taylor Roofing Ina
Evaluation Report for
26 ga. 5V Crimp Metal Roof Assembly
FL#14520-R1
Roof Assemblies:
• The product shall be installed in accordance with the Manufacturer's
instructions and the Roof Assemblies section herein.
• Modifications of the products as evaluated herein are beyond the scope of
this evaluation.
• All products listed herein shall have a quality assurance audit in accordance
with F.A.C. Rule 9B-72,
Assembiv No. 1
Max Design Pressure: -69.25
Slope: 2:12 or greater
Deck: Minimum 15/32" plywood or wood plank
DeckAIttachment. In accordance with the applicable Code. In no case less
than minimum 8d x 2" annular ring shank nails spaced 6"
o.c. In reroofing, where the deck is less than 19/32" thick
(minimum 15/32") the above attachment method must be
in addition to existing attachment. Deck attachment to
be designed by others,
Underlayment Minimum ASTM D 226, Type it (No. 30) in accordance
with Section 1507.2.5 of the 2010 Florida Building Code
or any Approved undedayment having current Florida
Statewide or Local Product Approval.
5V Crimp Panels: Installed in accordance with Manufacturer's installation
instructions. Minimum #9-15 corrosion resistant
fasteners with sealing washers designed for metal to
wood connections of sufficient length to penetrate 5/16"
through the sheathing installed 16" o.c. along the crown
of the rib in the center of'panel and along the lap (See
Drawings).
Assembly No. 2
Max ,Design Pressure:-129.25
Slope: 2:12 or greater
Deck. Minimum 15/32" plywood or wood plank
Deck Attachment in accordance with the applicable Code. In no case less
than minimum $d x 2" annular ring shank nails spaced 6"
o.c, In reroofing, where the deck is less than 19132" thick
(minimum 15/32') the above attachment method must be
in addition to existing attachment. Deck attachment to
be designed by others.
Underlayinent: Minimum ASTM D 226, Type II (No. 30) in accordance
with Section 1507.2.8 of the 2010 Florida Building Code
or any Approved undedayment having current Florida
Page 2 of 3
J.A. Taylor Roofing Inc.
Evaluation Report for
26 g& 5V Crimp Metal Roof Assembly;
FL# 14520-111
Statewide or Local Product Approval.
5V Crimp Panels: Installed in accordance with Manufacturer's installation
instructions. Minimum #9-15
corrosion resistant
fasteners With sealing washers designed for metal to
Wood connections of sufficient length to penetrate 5/16"
through the sheathing installed 8' o.c. along the crown of
the rib in the center of panel and along the lap (See
Drawings).
Drawings.
5-V PANEL PROFIL
24" Coverage
T-
I
Quality Assurance: Keyston, e Certifications. (FBC Organization No. QUAI 824)
Evaluator:;
Charles L. Thomas, P.E.'
Florida Registered ProfestlanM Engineer.�'
PE No.: 29439
FSC Organization No.: ANEqm
14609 Dixie Hwy, Huds6n,*L-34�6"7
Date:
Page 3 of 3