APPROVED, Design Pressure Report -
Property Information Owner:Robert or Helen Davis Address:382 S Naranja AVE Port St Lucie, FL 34983 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:40 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 71 35 7 36.5 -39.7 2 Int 52 64 7 35.7 -38.9 3 Int 34 81 7 36.2 -39.4 4 Int 36 37 7 37.8 -41.0 5 Int 25 38 7 37.8 -41.0 6 Int 25 37 7 37.8 -41.0 7 Int 36 37 7 37.8 -41.0 8 Int 36 37 7 37.8 -41.0 9 Int 91 80 7 33.8 -37.0 10 Int 26 81 7 36.8 -40.0 11 Int 73 50 7 35.5 -38.7 12 Int 36 50 7 37.2 -40.5 13 Int 60 80 7 34.8 -38.0 14 Int 108 80 7 33.4 -36.6 15 Int 107 79 7 33.4 -36.7 16 Int 25 37 7 37.8 -41.0 17 Int 25 37 7 37.8 -41.0 18 Int 52 63 7 35.8 -39.0 19 Int 52 76 7 35.3 -38.5 20 Int 52 76 7 35.3 -38.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1