HomeMy WebLinkAboutDeSantis Gen SpecsINCLUDES:
• True Power' Electrical Technology
• Two-line multilingual digital LCD Evolution" controller
(English/Spanish/French/Portuguese)
• 200 amp service rated smart switch transfer switch available
• Electronic governor
• Standard Wi-Fig connectivity
• System status & maintenance interval LED indicators
• Sound attenuated enclosure
• Flexible fuel line connector
• Natural gas or LP gas operation
• 5 Year limited warranty
• Listed and labeled by the Southwest Research Institute allowing
installation as close as 18 in (457 mm) to a structure.*
'Must be located away from doors, windows, and fresh air intakes and in
accordance with local codes.
https: //assets.swri.org/library/DirectoryOfListedProducts/
Constructionlndustry/973_DoC_204_13204-01-01 Rev9.pdf
FEATURES
GENERAC®
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz
G007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz
INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O
erac's success in providing the most reliable generators possible. Generac's G-
Force engine lineup offers added peace of mind and reliability for when it's needed
the most. The G-Force series engines are purpose built and designed to handle the
rigors of extended run times in high temperatures and extreme operating conditions.
0 TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5% Total Harmonic Distortion for utility quality power. This
allows confident operation of sensitive electronic equipment and micro -chip based
appliances, such as variable speed HVAC systems.
I Vwl
GENERAC,°
or C
cONusV� US n�' TM
LISTED �X ir�°�
Note: CETL or CUL certification only applies to unbundled units and units packaged
with limited circuit switches. Units packaged with the Smart Switch are ETL or UL
certified in the USA only.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
state-of-the-art power maximizing regulation system is standard on all Generac mod-
els. It provides optimized FAST RESPONSE to changing load conditions and MAXI-
MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads to the engine. Digital voltage regulation at ±1%.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the small-
est electronic component.
0 TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system
compatibility.
O MOBILE LINK* CONNECTIVITY: FREE with select Guardian Series Home standby
generators, Mobile Link Wi-Fi allows users to monitor generator status from any-
where in the world using a smartphone, tablet, or PC. Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
FGENERAC
PROMISE
GENERAC�
20/22 kW
Features and Benefits
Engine
•
Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
•
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows fora smaller, light weight unitthat operates 25% more efficiently than a revolving armature generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulating output voltage to ±1 % prevents damaging voltage spikes.
•
UL 2200 listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers vital electrical loads to the energized source of power.
•
NEMA 311
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near an existing distribution panel for simple, low-cost installation.
Evolution" Controls
•
AUTO/MANUAL/OFF illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
•
Two-line multilingual LCD display
Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to verify the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
• Engine warm-up
Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
• Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
• Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
• Main line circuit breaker
Protects generator from overload.
• Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
20/22 kW
Installation System
• 14 in (35.6 cm) flexible fuel line connector
• Integral sediment trap
connectivity (Wi-Fi equipped models only)
• Ability to view generator status
• Ability to view generator Exercise,/Run and Total Hours
• Ability to view generator maintenance information
• Monthly report with previous month's activity
• Ability to view generator battery information
• Weather information
GENERAC®
Features and Benefits
Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
Meets IFGC and NFPA 54 installation requirements.
Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind.
Review the generator's complete protection profile for exercise hours and total hours.
Provides maintenance information for the specific model generator when scheduled maintenance is due.
Detailed monthly reports provide historical generator information.
Built in battery diagnostics displaying current state of the battery.
Provides detailed local ambient weather conditions for generator location.
GENERACV
20/22 kW Specifications
Generator
Model
G007038-1, G007039-1 ,G7O 042-2,M076C-2 G007038-3, G007039-3 G007042-3, G007043-3
(20 kW) (22 kW) (20 kW) (22 kW)
Rated maximum continuous power capacity (LP)
20.000 Watts` atts' 20,000 Watts22,000 Watts`
Rated maximum continuous power capacity (NG)
18,000 Watts" 19,500 Watts ` 18,000 Watts' 19,500 Watts
Rated voltage
240
Rated maximum eontinuous,lead.curfeat — 24Q.volts:(LP/NG)
83.3 / 75.0 94%7 / 81.3 83.3 / 75.0 91.7 / 81.3
Total Harmonic Distortion
Less than 5%
Main line circuit breaker
90 amp 100 amp 90 amp 100 amp
Phase
1
Number of rotor poles
2
Rated AC frequency
60 Hz
Power factor
1.0
Battery requirement (not included)
12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum
Unit weight (Ile / kg)
448 / 203 466 / 211 436 / 198 445 / 202
Dimensions (L x W x H) in / cm
48 x 25 x 29 / 121.9 x 63.5 x 73.7
Sound output in cl at 23 It (7 m) with generator operating at normal load"
67 67 67 67
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'" low -speed exercise mode""
55 57 55 57
Exercise duration
5 min
Engine
Engine type
GENERAC G-Force 1000 Series
Number of cylinders
2
Displacement
999 cc
Cylinder block
Aluminum w/ cast iron sleeve
Valve arrangement
Overhead valve
Ignition system
Solid-state w/ magneto
Governor system
Electronic
Compression ratio
9.5:1
Starter
12 VDC
Oil capacity including filter
Approx. 1.9 qt/ 1.8 L
Operating rpm
3,600
Fuel consumption
Natural gas ft3/hr (mL
1/2 Looadad
204 (5.78) 228 (6.46) 164 (4.64) 203 (5.75)
Full Load
301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66)
Liquid propane fta/hr (gaVhr) Load L
Load
87 (2.37) [8.99] 92 (2.53) [9.57] 86 (2,36) [8.95] 92 (2.53) [9.571
FuI
Ful Load
130 (3.56) [13,48] 142 (3.90) [14.77] 136 (3.74) [14.15] 142 (3.90) [14.771
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all
load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG,10-12 in water column (2.49-2.99 kPa) for LP gas.
For BTU content, multiply ft3/hr x 2500 (LP) or 0/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG).
Controls
Two-line plain text multilingual LCD
Simple user interface for ease of operation.
Mode buttons: AUTO
Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser.
MANUAL
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
OFF
Stops unit. Power is removed. Control and charger still operate.
Ready to Run/Maintenance messages
Standard
Engine run hours indication
Standard
Programmable start delay between 2-1500 seconds
Standard (programmable by dealer only)
Utility Voltage Loss/Return to Utility adjustable (brownout setting)
From 140-171 V / 190-216 V
Future Set Capable Exerciser/Fxercise Set Error warning
Standard
Run/Alarm/Maintenance logs
50 events each
Engine start sequence
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
Starter lock -out
Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger
Standard
Charger Fault/Missing AC warning
Standard
Low Battery/Battery Problem Protection and Battery Condition indication
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection
Standard
Under-Frequency/Overload/Stepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal Fault/incorrect Wiring protection
Standard
Common external fault capability
Standard
Field upgradable firmware
Standard
"'Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying
emergency power for the duration of the utility power outage. No overload capability is available for
this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are
subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude,
engine power and condition, etc. Maximum power decreases approximately 3.5%for each 1,000 ft (304.8 m) above sea
level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C).
20/22 kW
GENERAC®
Switch Options
Service Rated Smart Switch Features G007039-1 (20 kW)
• Includes digital power management technology (DPM) standard. Model •—ee9704's-2'ttzkw)
• Intelligently manages up to four air conditioner loads with no additional hardware. G007039.3 (20 kw)
• Up to eight additional large (240 VAC) loads can be managed when used in No. of poles G007043(22 kw)) 2
conjunction with Smart Management Modules (SMMs). 2
Current rating -(amps) 200
• Electrically operated, mechanically -held contacts for fast, clean connections. Voltage rating (VAC) 120/240.10
• Rated for all classes of load,100% equipment rated, both inductive and resistive.
• 2-pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
Rated for both aluminum and copper conductors.
O Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting
flexibility.
Dimensions
200 Amps 120/240,10
Open Transition Service Rated
Height
Width
H1
H2
W1
W2
Depth
in
26.75
30.1
10.5
13.5
6.91
cm
67.95
76.45
26.67
34.29
17.55
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
400 MCM - #4
350 MCM - #6
1 2/0 - #14
Utility voltage monitor (fixed)*
-Pick-up
-Dropout
Return to Utility*
Exercises bi-weekly for 5 minutes*
ETL or UL listed
-ft"Mm—
Circuit breaker protected
Lug range
*Function of Evolution controller
Exercise can be set to weekly or monthly
DEPTH
80%
65%
Approx.13 sec
Standard
Standard
22,000
250 MCM - #6
GENERAL`
20/22 kW
Available Accessories
Model # Product
Description
G005819-0 26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery
for use with all air-cooled standby product (excluding PowerPact®).
G007101-0 Battery Pad Warmer
' Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 IF (-18 °C). (Not
necessary for use with AGM -style batteries).
G007102-0 Oil Warmer
Oil warmer slips directly over the oil filter. Recommended for use if temperature regularly falls below 0 IF (-18 °C).
G007103-1 Breather Warmer
Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates
where heavy icing occurs.
G005621-0 Auxiliary Transfer Switch
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not
Contact Kit
be needed. Not compatible with 50 amp pre -wired switches.
G007027-0 - Bisque 1 Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, con -
(Standard on 22 kW)
toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the
base.
G005703-0 - Bisque Touch -Up Paint Kit
If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corro-
sion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0 Scheduled Maintenance Kit
Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a
Generac automatic standby generator (oil not included).
G007005-0 Wi-Fi LP Tank Fuel Level
The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring
Monitor
the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected powerfailure.
Status alerts are available through a free application to notify users when the LP tank is in need of a refill.
G007000-0 (50 amp) Smart Management Module
Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large
G007006-0 (100
electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can
amp)
reduce the overall size and cost of the system.
G007169-0 Mobile Link® Cellular
The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world,
Accessories
using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance
alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
Dimensions & PCs
Model
UPC
G007038-1
696471074185
G007038-3
696471074185
G007039-1
696471074192
G007039-3
696471074192
G007042-2
696471074208
G007042-3
696471074208
G007043-2
696471074215
G007043-3
696471074215
GENERAC®
72'
r2
LEFT SIDE VIEW
FRONT VIEW
Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000221268 Rev. B 05/28/2020