Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential P Project Name: Lot 120 Block 5 Waterstone 1820 CGL Builder Name: ADAMS HOMES FEB 2 3 2021 Street: 5342 San Benedetto Place Permit Office: City, State, Zip: Fort pierce , FL , 34951 Permit Number: ST,,Lucle County, Owner: Jurisdiction: 661000 Permitti Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(239.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 364 a. U-Factor: Dbl, U=0.33 136.36 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.36 32.38 ft2 SHGC: SHGC=0.29 Area Weighted Average Overhang Depth: 4.248 ft. 14. Heating systems /hr kBtu/hr Efficiency Efficiency Area Weighted Average SHGC: 0.277 a. Electric Heat Pump HS 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap:, 40 gallons 9. Floor Types (1820.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 62.38 PASS Total Baseline Loads: 65.00 I hereby certify that the plans an tions covered b ��""' Revie f the plans and this calculation are in complia e t e Fold gy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed " DATE: 01-28-2021 Winn KPnmany this building will be inspected for compliance with Section 553.908 d. I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/28/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 120 Block 5 Waterstone 1 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 120-5 Block/Subdivision: Waterstone PlatBook: Street: 5342 San Benedetto PI County: St. Lucie City, State, Zip: Fort pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area ' Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ftz ---- 0.42 0 0.58 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ftZ 456 ft' Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 1820 ftZ 0.11 Wood 80 ftz 0.11 Wood 1/28/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 SW Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 SE Exterior Concrete Block - Int In'sul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 NE Exterior Concrete Block - Int Insul Main I 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 NW Exterior Concrete Block - Int Irisul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None None 2 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 3 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 0 in 0 ft 6 in None None 4 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 5 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 6 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in None None 7 NE 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 8 NW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 4 in 0 ft 6 in None None 9 NW 4 Vinyl Low-E Double Yes 0.36 0.29 N 32.4 ft2 1 ft 4 in 0 ft 10 in None None 10 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 4 in 0 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/28/2021 10:47 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinHJan HFeb Mar Mar HX A r Apr Jul May Jun Jul Ma X Jun ri f AuSeP Augri Se Oct Oct Nov Nov HX Dec Dec H Ventin Jan Feb Mar [ Apr [ May [ Jun Jul [ Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 1/28/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 w ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED'ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 5342 San Benedetto Place, Fort pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 . 1850.00 ft' b. Frame - Wood, Adjacent R=13.0 270.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1820.00 ft' 6. Conditioned floor area (W) 18201 b. Knee Wall (Vented) R=19.0 80.00 ft' 7. Windows** Description Area R _ z a. U-Factor: Dbl, U=0.33 136.36 ft' 12. uc s, location & insulation level R ft' a. Sup: Attic, Ret: Main, AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft' SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.36 32.38 ft' a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.29 d. U-Factor: other (see details) 38.19 ft' SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 4.248 ft. Area Weighted Average SHGC: 0.277 8. Skylights Description Area 15. Hot water systems Cap: 40 gallons a. U-Factor(AVG): N/A ft' a. Electric SHGC(AVG): N/A EF: 0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft' Credits (Performance method) Pstat b. N/A R= ft' c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/28/2021 10:47 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1