HomeMy WebLinkAboutCompaction Test411Y tij In -Place Density Report
& Associates, Inc. Permit # 2101-0419
Report Date: 3/22/2021
Port St. Lucie Branch Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772-878.0072
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Retest
Soil
Moisture
Density (pcf)
Moisture
Density
Density
Depth
Percent
Min Comp.
Test #
Of
Test Date
Proctor ID
Method
Classification
%
%)
pc
(pcf)
(in)
Compaction
%)
Remark
440
3/18/21
21-017
A
-
9.0
122.0
11.1
119.7
133.0
12
98
95
Pass
Modified
441
3/18/21
21-017
A
-
9.0
122.0
9.2
120.3
131.4
12
99
95
Pass
(Modified)
442
3/18/21
21-017
A
-
9.0
122.0
10.0
122.8
135.1
12
101
95
Pass
(Modified)
443
3/18/21
21-017
A
9.0
122.0
10.6
120.1
132.8
12
98
95
Pass
(Modified)
Test
Information
Gauge
Test #
Test Location
Elevation
Reference
Make I Model / SN I Calibrated
Field Technician
440
Building Pad Fill: House Pad at 313 Palm Breezes Drive, Lot 18. Footing, North Side,
-1.0
Top of Footing
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
Center
441
Building Pad Fill: House Pad at 313 Palm Breezes Drive, Lot 18. Footing, South Side,
-1.0
Top of Footing
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Center
442
Building Pad Fill: House Pad at 313 Palm Breezes Drive, Lot 18. Pad, West Side,
-1.0
Top of Pad
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Center
443
Building Pad Fill: House Pad at 313 Palm Breezes Drive, Lot 18. Pad, East Side,
-1.0
Top of Pad
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
Center
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter".
Gauge calibration data on file with the testing agency.
i4t- /f Digitally signed
by Dan J
M00%Zrallack:
Date: 2021,03.22
13:10:09-04'00'
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RE�
PENDING OUR WRITTEN APPROVAL.
�\\W t I I I I1/////,
_�VI 63s11 1�=
O
/IlIII111\\�
3-22-21
ge1of1